1
|
Kim JW, Eom Y, Bae SH, Jeon HS, Kim SJ, Kim DH, Song JS. Visual Outcomes According to Age After Bilateral Implantation of Trifocal Intraocular Lenses. J Refract Surg 2024; 40:e270-e277. [PMID: 38593255 DOI: 10.3928/1081597x-20240314-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/11/2024]
Abstract
PURPOSE To investigate the effect of age on visual outcomes after the bilateral implantation of trifocal intraocular lenses (IOLs). METHODS A total of 290 patients (580 eyes) who underwent bilateral implantation of a trifocal IOL were enrolled in this retrospective case-control study. Patients were divided into five age groups: 45 to 49, 50 to 54, 55 to 59, 60 to 64, and 65 years and older. Postoperative monocular uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively), uncorrected near visual acuity (UNVA), binocular distance-corrected defocus curve, spectacle dependence for near and distance vision, and patient satisfaction scores were compared among the five groups. RESULTS The 45 to 49 years group had significantly better mean UDVA (0.02 ± 0.05 logMAR) and UNVA (0.02 ± 0.04 logMAR) than the 65 years and older group (0.06 ± 0.09 and 0.09 ± 0.09 logMAR; P = .029 and P < .001; respectively). However, no significant differences were observed in the mean CDVA among the groups. Binocular visual performance of the 45 to 49 years group was better than that of the 65 years and older age group at defocuses of +1.00, +0.50, -1.00, and -3.00 D. No significant differences were observed in spectacle dependence for near and distance vision or in patient satisfaction scores among the five groups. CONCLUSIONS Bilateral implantation of trifocal IOLs can provide excellent near and distance vision in both young and older patients. However, UDVA and UNVA revealed considerably worse results in the older group, although no significant difference was observed in CDVA and postoperative refractive errors by age. [J Refract Surg. 2024;40(4):e270-e277.].
Collapse
|
2
|
Kohnen T, Nouri SA, Carson D. Vehicle Headlight Halo Simulation of Presbyopia-Correcting Intraocular Lenses. Transl Vis Sci Technol 2023; 12:19. [PMID: 38127324 PMCID: PMC10746926 DOI: 10.1167/tvst.12.12.19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 10/16/2023] [Indexed: 12/23/2023] Open
Abstract
Purpose This optical bench study was designed to evaluate and compare the halos generated by presbyopia-correcting intraocular lenses (PCIOLs) and monofocal intraocular lenses (IOLs), with or without lens decentration, using an optical bench to simulate the headlight of a distant vehicle in mesopic conditions. Methods Halos generated by six nondiffractive and 10 diffractive IOLs with different dioptric add powers were evaluated using a high dynamic range bench system. Halo intensities were compared by assessing the area under the measured intensity profile curve to compute the relative halo magnitude (RHM). Results Nondiffractive PCIOLs produced smaller and less intense bench halo images than diffractive ones. RHM measurements ranged from 964 to 1896. Monofocal IOLs produced lower RHM values, whereas diffractive PCIOLs generated higher ones. When decentered by 0.5 mm with respect to the system aperture, more obviously asymmetric halo image profiles were observed in diffractive compared with nondiffractive PCIOLs. Conclusions Simulated bench halos of nondiffractive PCIOLs are smaller and less intense than those of diffractive PCIOLs. Additional clinical studies assessing standardized patient-reported outcomes measures are required to correlate these bench results with patient satisfaction. Translational Relevance This study contrasts the design-related simulated bench halos of nondiffractive and diffractive PCIOLs, aiming to elucidate their impact on halo perception.
Collapse
Affiliation(s)
- Thomas Kohnen
- Department of Ophthalmology, Goethe University, Frankfurt, Germany
| | | | | |
Collapse
|
3
|
Skrzypecki J, Izdebska J, Ordon AJ, Przybek-Skrzypecka J, Szaflik JP. Spherical aberrations and their role in modern ophthalmology. Clin Exp Optom 2023; 106:703-710. [PMID: 36822601 DOI: 10.1080/08164622.2022.2160235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 10/31/2022] [Accepted: 11/03/2022] [Indexed: 02/25/2023] Open
Abstract
Spherical aberration is an imperfection of the optical system of the human eye. The role of spherical aberration of the human eye in the quality of vision and pseudoaccommodation is reviewed. Spherical aberration is an imperfection of the optical system of the human eye. In most cases, due to well-developed neuroadaptation, it is insignificant for the perception of the image. Nevertheless, its role in modern ophthalmology is far from straightforward. On the one hand, there are clinical scenarios in which an excess of spherical aberration degrades the retinal image and leads to a high dissatisfaction rate among patients.©Recently, there is a growing interest in the modulation of spherical aberration in the clinical setting. Modern intraocular lenses as well as laser refractive procedures are aimed at interfering with spherical aberrations of the optical system in order to increase range of pseudoaccommodation. Here, we review the role of spherical aberration of the human eye in the quality of vision and pseudoaccommodation.
Collapse
Affiliation(s)
- Janusz Skrzypecki
- Departament of Ophthalmology, Independent Public University Eye Hospital, Warsaw, Poland
- Department of Experimental Physiology and Pathophysiology, Medical University of Warsaw, Warsaw, Poland
| | - Justyna Izdebska
- Departament of Ophthalmology, Independent Public University Eye Hospital, Warsaw, Poland
- Department of Ophthalmology, Medical University of Warsaw, Warsaw, Poland
| | - Agata Joanna Ordon
- Departament of Ophthalmology, Independent Public University Eye Hospital, Warsaw, Poland
- Department of Binocular Vision Pathophysiology and Strabismus, Medical University of Lodz, Lodz, Poland
| | - Joana Przybek-Skrzypecka
- Departament of Ophthalmology, Independent Public University Eye Hospital, Warsaw, Poland
- Department of Ophthalmology, Medical University of Warsaw, Warsaw, Poland
| | - Jacek Pawel Szaflik
- Departament of Ophthalmology, Independent Public University Eye Hospital, Warsaw, Poland
- Department of Ophthalmology, Medical University of Warsaw, Warsaw, Poland
| |
Collapse
|
4
|
Kohnen T, Lapid-Gortzak R, Ramamurthy D, Bissen-Miyajima H, Maxwell A, Kim TI, Modi S. Clinical Outcomes After Bilateral Implantation of a Diffractive Trifocal Intraocular Lens: A Worldwide Pooled Analysis of Prospective Clinical Investigations. Clin Ophthalmol 2023; 17:155-163. [PMID: 36647516 PMCID: PMC9840399 DOI: 10.2147/opth.s377234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2022] [Accepted: 11/21/2022] [Indexed: 01/11/2023] Open
Abstract
Purpose To investigate visual and safety outcomes of AcrySof® IQ PanOptix® (model TFNT00), a trifocal, presbyopia-correcting intraocular lens (IOL), in patients of different ethnicities across multiple countries, based on a pooled analysis of six prospective multicenter studies. Patients and Methods This pooled analysis included adult patients from six prospective clinical studies performed across 56 centers worldwide. After cataract removal by phacoemulsification, all patients were implanted with TFNT00; follow-up duration varied from 3 to 12 months according to the studies' design. Binocular defocus curve; absolute manifest refraction spherical equivalent (MRSE); and binocular photopic uncorrected and corrected visual acuities at distance (UCDVA, BCDVA; 4-5 m), intermediate (UCIVA, DCIVA; 60-66 cm), and near (UCNVA, DCNVA; 40 cm) were measured. Results The study included 557 patients, 547 of whom were implanted bilaterally with the TFNT00 IOL (n = 1094 eyes). Binocular visual data at 1 month and 3-6 months after implantation were available for up to 546 and 542 bilaterally implanted patients, respectively. A continuous range of 0.1 logarithm of the minimum angle of resolution (logMAR) or better vision from distance (0.00 diopter [D], 4-5 m) to near (-3.00 D; optically equivalent to 33 cm) was observed 3-6 months after TFNT00 implantation. At 3-6 months, 88.2% of first eyes achieved an MRSE ≤0.50 D and 88.7% of second eyes achieved an MRSE ≤0.50 D. Overall, 99.3%, 92.3%, and 94.6% of patients bilaterally implanted with TFNT00 achieved binocular photopic BCDVA, DCIVA, and DCNVA of 0.14 logMAR or better, respectively. Ocular adverse device effects and secondary surgical interventions (SSIs) were infrequent. Conclusion This global pooled analysis showed that TFNT00 provided a continuous range of 0.1 logMAR (~20/25 Snellen) or better vision from distance to 33 cm, with a low incidence of ocular adverse device effects and SSIs.
Collapse
Affiliation(s)
- Thomas Kohnen
- Department of Ophthalmology, Goethe-University, Frankfurt, Germany,Correspondence: Thomas Kohnen, Department of Ophthalmology, Goethe University, Theodor‑Stern-Kai 7, Frankfurt, 60590, Germany, Tel +49 69 6301 6739/ 3945, Fax +49 69 6301 3893, Email
| | - Ruth Lapid-Gortzak
- Department of Ophthalmology, Amsterdam University Medical Centers, Amsterdam, Netherlands
| | | | | | | | - Tae-Im Kim
- Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea
| | | |
Collapse
|
5
|
Karuppiah P, Varman NVA, Varman A, Balakumar D. Comparison of clinical outcomes of trifocal intraocular lens (AT LISA, Eyecryl SERT trifocal) versus extended depth of focus intraocular lens (Eyhance, Eyecryl SERT EDOF). Indian J Ophthalmol 2022; 70:2867-2871. [PMID: 35918933 DOI: 10.4103/ijo.ijo_2921_21] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Purpose To compare four different types of intra ocular lenses (IOLs), namely, AT LISA, Eyecryl SERT trifocal, Eyhance, Eyecryl SERT extended depth of focus (EDOF) with respect to their clinical outcomes. Methods This is a retrospective comparative study in which patients who underwent surgery and one of the four types of IOL were implanted. Postoperative evaluation was recorded at one month, postoperatively. The monocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) (6 m), uncorrected intermediate visual acuity (UIVA) (60 cm), distance-corrected intermediate visual acuity (CIVA), uncorrected near visual acuity (UNVA) (40 cm), and corrected near visual acuity (CNVA) were assessed postoperatively on post operative day 30, for all four IOL groups. Defocus curve and contrast sensitivity were also compared. Results With regards to UDVA and CDVA, P value was not statistically significant. (P = 0.534 and 0.421, respectively). EDOF group of IOLs had statistically significant better UIVA and CIVA than trifocal IOL group. (P < 0.001, 0.012, <0.001) and EDOF group had statistically significant worse P value pertaining to UNVA and CNVA (P < 0.001, 0.070, <0.001, 0.190). Pertaining to contrast sensitivity, EDOF group had better contrast sensitivity than Trifocal IOL group (P < 0.001). Conclusion All four IOLs compared in this study had good comparable distant visual acuity. Near visual acuity was better with AT LISA and Eyecryl SERT trifocal IOL while intermediate vision was better with Eyhance and Eyecryl SERT EDOF IOL. Contrast sensitivity was better in EDOF IOLs than in both trifocal IOLs.
Collapse
|
6
|
Na KS, Kim SJ, Nam G, Ha M, Whang WJ, Kim EC, Kim HS, Hwang HS. A Novel Intraocular Lens Simulator that Allows Patients to Experience the World Through Multifocal Intraocular Lenses Before Surgeries. Transl Vis Sci Technol 2022; 11:14. [PMID: 35275206 PMCID: PMC8934550 DOI: 10.1167/tvst.11.3.14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to investigate whether the intraocular lens (IOL) simulator can simulate how the world appears to patients with multifocal IOLs by allowing the patients to see far and near objects through the IOL simulator. Methods Twenty eyes from 20 patients (age = 50-70 years old) were included in the study. The IOL simulator we developed consists of a trial lens frame adapter, a lens tube, a concave lens, a spacer, a wet cell, and an IOL. We used two IOLs: Tecnis monofocal and Tecnis bifocal IOL (add +3.25 diopter [D]). Patients wore a trial lens frame with an IOL simulator on distant corrected trial lenses and underwent the following tests: defocus curve, satisfaction with distance and near vision, halo around the light, and near point accommodation (NPA). To check how the world appears to the patients through this simulator, a machine vision lens and a scientific camera were attached to the simulator, and far and near objects were photographed. Results In the defocus curve of multifocal IOL, the visual acuity showed the second peak at -4 D. Compared to monofocal IOL, satisfaction with distant vision was slightly worse, more halos were felt, satisfaction with near vision was higher, and the NPA was shorter in multifocal IOL. In the scientific camera test, through the multifocal IOL, the waiting room was blurry, the halo around the ceiling light was prominent, and the characteristics on the near visual acuity chart were clear. Conclusion Subjects could experience the functions of multifocal IOLs with our newly developed IOL simulator. Translational Relevance This IOL simulator using geometric optics allows patients to experience the function of multifocal IOLs before cataract surgery.
Collapse
Affiliation(s)
- Kyung-Sun Na
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Seong-Jae Kim
- Department of Ophthalmology, Gyeongsang National University Hospital, Gyeongsang National University College of Medicine, Jinju, Korea
| | - Gahee Nam
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Minji Ha
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Woong-Joo Whang
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Eun Chul Kim
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Hyun-Seung Kim
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Ho Sik Hwang
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| |
Collapse
|
7
|
Kim JW, Eom Y, Yoon EG, Song JS, Jeong JW, Park SK, Kim HM. Increased Near Vision Spectacle Dependence of Patients With Preoperative Myopia After Mix-and-Match Implantation of Trifocal EDOF and Trifocal IOLs. J Refract Surg 2021; 37:746-753. [PMID: 34756137 DOI: 10.3928/1081597x-20210802-02] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
PURPOSE To investigate the factors affecting near vision spectacle dependence after mix-and-match implantation of the trifocal extended depth of focus (EDOF) and trifocal intraocular lens (IOL). METHODS A total of 204 eyes of 102 patients who underwent mix-and-match implantation of one trifocal EDOF and one trifocal IOL were enrolled in this study. Patients were divided into two groups according to spectacle dependence for near vision: reading glasses and no glasses. Clinical characteristics were compared between the two groups and multivariate binary logistic regression analysis was performed to determine the odds ratio of factors potentially associated with the need for reading glasses. RESULTS Eighty-one patients (79.4%) did not need reading glasses and 21 (20.6%) did. The mean age of the no glasses group (55.6 ± 5.6 years) was significantly higher than that of the reading glasses group (52.7 ± 4.1 years). Preoperative refractions were more myopic in the reading glasses group than in the no glasses group. The postoperative uncorrected near visual acuities were better and the satisfaction scores were higher in the no glasses group compared to the reading glasses group. Multivariate binary regression analysis revealed that only pre-operative spherical equivalent (odds ratio: 1.397; P = .025) was related to the spectacle independence for near vision. CONCLUSIONS Patients who had preoperative myopia and underwent mix-and-match implantation of trifocal EDOF and tri-focal IOLs tended to need spectacles for near vision. Surgeons should be aware of patients with myopia when considering mix-and-match implantation of trifocal EDOF and trifocal IOLs. [J Refract Surg. 2021;37(11):746-753.].
Collapse
|
8
|
Zhong Y, Zhu Y, Wang W, Wang K, Liu X, Yao K. Femtosecond laser-assisted cataract surgery versus conventional phacoemulsification: comparison of internal aberrations and visual quality. Graefes Arch Clin Exp Ophthalmol 2021; 260:901-911. [PMID: 34636992 DOI: 10.1007/s00417-021-05441-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2021] [Revised: 10/01/2021] [Accepted: 10/01/2021] [Indexed: 01/19/2023] Open
Abstract
PURPOSE To compare the internal aberrations and optical quality after femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification cataract surgery (CPCS). METHODS This study included patients who received FLACS or CPCS from January 2016 to July 2019. Postoperative examinations included wavefront measurements under pupil diameters of 3.0 mm and 5.0 mm, intraocular lens (IOL) decentration, visual acuity (VA), and refractive outcomes. Visual quality was measured with Strehl ratio and modulation transfer function (MTF). Subgroup analyses were conducted based on monofocal or multifocal-extended depth of focus (EDOF) IOL. RESULTS The study consisted of 221 eyes (105 eyes in FLACS and 116 eyes in CPCS). With a pupil diameter of 5.0 mm, FLACS demonstrated a significantly lower root mean square of total internal aberration (P = 0.004), higher order aberrations (HOAs) (P = 0.034), tilt (P = 0.049), coma (P = 0.004), and spherical aberration (P = 0.014). IOL tilt was found to be positively correlated with total internal aberration (P < 0.001), HOAs (P < 0.001), and coma (P < 0.001). The FLACS group presented significantly smaller IOL decentration than the CPCS group (P < 0.001), but there were no significant differences in terms of VA and refractive outcomes between groups. In the multifocal-EDOF subgroup, Strehl ratio and MTF values were significantly higher in the femtosecond group with a 3.0-mm pupil. CONCLUSION FLACS induced significantly lower values of IOL tilt, decentration, and internal aberrations compared with the CPCS group with a pupil diameter of 5.0 mm, while no significant differences were found in the VA or optical quality over long-term observation. TRIAL REGISTRATION This trial was registered at www.chictr.org.cn (registration number ChiCTR2000038965).
Collapse
Affiliation(s)
- Yueyang Zhong
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China
| | - Yanan Zhu
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China
| | - Wei Wang
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China
| | - Kai Wang
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China
| | - Xin Liu
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China
| | - Ke Yao
- Eye Center of the Second Affiliated Hospital, School of Medicine, Zhejiang University, No. 88 Jiefang Road, Hangzhou, 310009, Zhejiang Province, China.
| |
Collapse
|
9
|
Citation network analysis of the various types of multifocal intraocular lenses. ARCHIVOS DE LA SOCIEDAD ESPAÑOLA DE OFTALMOLOGÍA 2021; 96:527-544. [PMID: 34620483 DOI: 10.1016/j.oftale.2020.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Accepted: 11/21/2020] [Indexed: 11/20/2022]
Abstract
BACKGROUND AND OBJECTIVE The implantation of multifocal intraocular lens (IOL) has increased in recent years, allowing patients to achieve good quality vision at all distances, independence from use of glasses, and consequently, an increase in quality of life. The main purpose of this study was to analyse the links between publications and authors via citation networks, as well to as identify the different research areas and determine the most cited publications. MATERIAL AND METHODS The publication search was performed through the Web of Science database, using the terms «Multifocal intraocular lens», «Bifocal intraocular lens», «Trifocal intraocular lens», «Diffractive intraocular lens», «Refractive intraocular lens», «Accommodative intraocular lens» and «Extended depth of focus intraocular lens», for a time interval from 1989 to August 2020. The software used to analyse the publications was the Citation Network Explorer. RESULTS A total of 1293 publications were found, with 11,730 citations generated in the network, and 2019 had the highest number of publications of any year. The most cited publication was «European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens» by Kohnen et al., published in 2006. Four groups about different research areas in this field were found using the Clustering functionality: visual quality, IOL designs, ocular aberrations, or defocus curves. CONCLUSIONS The citation network offers an objective and comprehensive analysis of the main articles on the different designs and classes of multifocal IOL.
Collapse
|
10
|
Multicenter visual outcomes comparison of 2 trifocal presbyopia-correcting IOLs: 6-month postoperative results. J Cataract Refract Surg 2021; 46:1534-1542. [PMID: 32541365 DOI: 10.1097/j.jcrs.0000000000000274] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE To clinically evaluate visual performance of the AcrySof IQ PanOptix TFNT00 and AT LISA tri 839MP intraocular lenses (IOLs) in binocular visual acuity (VA) and to characterize low-contrast visual performance at 6 months postimplantation. SETTING Multicenter, 15 sites. DESIGN Prospective, parallel-group, randomized, double-masked, postmarketing clinical study. METHODS Binocular uncorrected distance (UDVA, 4 m), intermediate (UIVA, 60 cm), and near (UNVA, 40 cm) visual acuities and binocular defocus curves were evaluated under photopic lighting conditions. Photopic and mesopic contrast sensitivities with and without glare were assessed. RESULTS The study included 182 subjects (62% women; mean age, 66 ± 9.4 years) who were implanted bilaterally with the TFNT00 IOL (n = 93) or 839MP IOL (n = 89), and binocular VA was evaluated 4 to 6 months (120-180 days) postimplantation. The TFNT00 IOL group showed superior visual outcomes compared with the 839MP IOL group in binocular UIVA (P = .001) and UNVA (P = .003) and noninferior outcomes in UDVA (95% CI, -0.023 to 0.041; upper limit <0.1 logarithm of the minimum angle of resolution [logMAR] [margin of noninferiority]). Mean defocus curve from 0.00 to -3.00 diopter (D) ranged from 0.1 to 0.0 logMAR for both IOLs; better mean VA values (logMAR) were observed in the TFNT00 IOL group between -1.50 and -2.50 D compared with those of the 839MP IOL group. Contrast sensitivity values were similar between the 2 groups in all conditions. CONCLUSIONS The results of this study showed improved visual performance at near and intermediate distances with the TFNT00 IOL compared with that of the 839MP IOL.
Collapse
|
11
|
Kohnen T, Marchini G, Alfonso JF, Bala C, Cochener B, Martinez A, Carreño E. Innovative trifocal (quadrifocal) presbyopia-correcting IOLs: 1-year outcomes from an international multicenter study. J Cataract Refract Surg 2021; 46:1142-1148. [PMID: 32358415 PMCID: PMC7688079 DOI: 10.1097/j.jcrs.0000000000000232] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Trifocal IOLs provided an excellent safety profile with satisfactory patient outcomes for UDVA, DCIVA, and UNVA. Defocus curve demonstrated 20/25 Snellen or better visual acuity at near to intermediate distance. Purpose: To evaluate visual acuity (VA) and safety of the new AcrySof IQ PanOptix presbyopia-correcting IOL at 12 months postimplantation. Setting: Seventeen sites in Europe, Australia, and South America. Design: Prospective, single-arm, nonmasked, nonrandomized study. Methods: Of 167 patients enrolled, 149 received study IOLs in both eyes; 145 completed the study. Binocular uncorrected distance VA (UDVA; 4 m), monocular corrected distance VA (CDVA), binocular distance-corrected intermediate VA (DCIVA; 60 cm and 80 cm), binocular uncorrected near VA (UNVA; 40 cm), and binocular defocus curves were evaluated. Safety was assessed by monitoring adverse events (AEs). Results: Of 149 patients, 92 patients (62%) were women and 139 patients (93%) were white; mean ± SD age was 68.9 ± 9.3 years. At 12 months, mean binocular UDVA was 0.02 ± 0.11 logarithm of the minimum angle of resolution (logMAR); monocular CDVA was 0.01 ± 0.13 logMAR (first eye) and 0.01 ± 0.10 logMAR (second eye); binocular DCIVA was 0.04 ± 0.12 logMAR and 0.08 ± 0.14 logMAR at 60 cm and 80 cm, respectively; and binocular UNVA was 0.07 ± 0.11 logMAR. At 6 months, mean binocular defocus curve VA (0.00 diopter [D] to −3.00 D) ranged from −0.04 to 0.13 logMAR. Binocular VA at distance (0.00 D), intermediate (−1.50 D), and near (−2.50 D) was −0.04 ± 0.11 logMAR, 0.07 ± 0.13 logMAR, and 0.07 ± 0.13 logMAR, respectively. Serious ocular AE rates were 1.4% or less in first and second eyes. Posterior capsulotomy rates were 3.4% (first eye) and 2.7% (second eye). Conclusions: The study IOL provided good VA outcomes. Defocus curve showed VA of 20/25 Snellen or better from near to intermediate distance. Rates of serious and nonserious AEs were low.
Collapse
Affiliation(s)
- Thomas Kohnen
- From the Department of Ophthalmology, Goethe-University (Kohnen), Frankfurt, Germany; Eye Clinic, Department of Neurosciences, Biomedicine and Movement, University of Verona, AOUI-Borgo Roma Hospital (Marchini), Verona, Italy; Fernández-Vega Ophthalmological Institute, School of Medicine, University of Oviedo (Alfonso), Oviedo, Spain; Department of Ophthalmology, Macquare University (Bala), Sydney, NSW, Australia; Ophthalmology Department, University Hospital CHU (Cochener), Brest, France; Alcon Vision LLC (Martinez), Fort Worth, Texas, USA; Centro Oftalmologico Carreño (Carreño), Santiago, Chile
| | | | | | | | | | | | | |
Collapse
|
12
|
Suryakumar R, Maxwell A. Biometric assessment of pseudophakic subjects during objective accommodative stimulation: a prospective observational study. Clin Exp Optom 2021; 105:398-403. [PMID: 34228948 DOI: 10.1080/08164622.2021.1924624] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
Clinical relevance: Ultrasound biomicroscopy is an objective method for assessing changes in anterior segment biometry. There is a paucity of data on the reliability of this method. A reliable method for assessing anterior segment changes during physiologically driven accommodation can be a useful tool for clinicians, researchers, and industry.Background: To assess the test-retest reliability of ultrasound biomicroscopy for measurements of change in anterior chamber depth during a distance to near fixation task in pseudophakic subjects.Methods: Subjects were adults with monofocal intraocular lenses implanted in both eyes who completed a 6-month post-operative period and had monocular uncorrected distance visual acuity of 6/15 (0.4 logMAR) or better. The change in anterior chamber depth during a distance to near fixation task was measured with a 35-MHz VuMAX HD ultrasound biomicroscopy device (Sonomed Escalon, New Hyde Park, NY) during two separate visits. An asymmetrical vergence paradigm allowed evaluation of anterior segment biometry at 22-µm axial resolution in one eye, while the fellow eye fixated on the target. To assess the test-retest reliability, 2-sided 95% CI from a paired t test was calculated for the difference in anterior chamber depth change from distance to near between visits.Results: The mean (standard deviation) near-focused anterior chamber depth measured by ultrasound biomicroscopy was 4.331 (0.237) and 4.333 (0.241) mm at visits 1 and 2, respectively. In response to a change in fixation from distance (4 m) to near (40 cm), the mean anterior chamber depth change was -0.012 (0.038) and 0.003 (0.039) mm at visits 1 and 2, respectively. Analysis of the difference in the change in anterior chamber depth between visits was -0.015 mm (95% CI, -0.035 to 0.003).Conclusion: Ultrasound biomicroscopy is a repeatable, objective method for assessing change in anterior segment biometry during physiological changes in fixation from distance to near.
Collapse
|
13
|
Park WC, Kim CH, Jin SW. Clinical performance of presbyopia correction with a multifocal corneoscleral lens. Int J Ophthalmol 2021; 14:529-535. [PMID: 33875943 DOI: 10.18240/ijo.2021.04.08] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Accepted: 08/24/2020] [Indexed: 11/23/2022] Open
Abstract
AIM To assess the clinical performance of a multifocal corneoscleral lens for the presbyopia correction. METHODS A prospective clinical trial of the Onefit™ A multifocal corneoscleral lens was conducted with 40 participants with presbyopia. At 4wk of continuous wear of the corneoscleral lens, changes in the distance, intermediate, and near visual acuity (VA) were evaluated. The safety of the corneoscleral lens, central corneal thickness (CCT), corneal endothelial cell count, binocular stereopsis, tear film break-up time (BUT), corneal staining, corneal edema, corneal neovascularization (NV), and conjunctival hyperemia were examined. In addition, a subjective questionnaire addressing satisfaction (rated from 1 to 5 points) and discomfort (rated from 1 to 5 points) was administered. RESULTS Forty participants were enrolled in this study. Six participants were excluded because of poor compliance with lens fitting (n=2) and loss to follow-up (n=4). The mean age of the participants was 53.0±4.9y. At 4wk of continuous wear of the corneoscleral lens, the best corrected far, intermediate, and near VA was 0.08±0.11, 0.10±0.12, and 0.10±0.12 logMAR, respectively. These results were significant improvements over the baseline uncorrected VA (far: P=0.004; intermediate: P=0.004; near: P=0.002). CCT, corneal endothelial cell count, binocular stereopsis, BUT, corneal staining, corneal edema, corneal NV, and conjunctival hyperemia were not significantly different between baseline and after corneoscleral lens use. The average satisfaction scores for fit sensation; corrected far, intermediate, and near VA; and ease of handling were 4.1, 3.4, 3.6, 3.5, and 3.4, respectively. The average discomfort scores for dryness, irritation, foreign body sensation, redness, fogging, and halo were 1.7, 1.8, 1.5, 1.7, 1.7, and 1.3, respectively. CONCLUSION Far, intermediate, and near VA are improved in presbyopic patients with the multifocal corneoscleral lens compared to uncorrected baseline VA, without adverse ocular effects. This evidence supports the safety and effectiveness of presbyopia correction with multifocal corneoscleral lenses.
Collapse
Affiliation(s)
- Woo Chan Park
- Department of Ophthalmology, Dong-A University College of Medicine, Busan 49201, Republic of Korea
| | - Chae Hoon Kim
- Department of Ophthalmology, Dong-A University College of Medicine, Busan 49201, Republic of Korea
| | - Sang Wook Jin
- Department of Ophthalmology, Dong-A University College of Medicine, Busan 49201, Republic of Korea
| |
Collapse
|
14
|
Abstract
The extended depth-of-focus (EDOF) intraocular lens (IOL) is an emerging technology that is designed to improve range of vision, especially at intermediate distances. In this review, we describe the clinical performance of 4 emerging EDOF IOL technologies; that is, small aperture, bioanalogic, diffractive optics, and nondiffractive optical manipulations. The American Academy of Ophthalmology generated a consensus statement for EDOF IOLs that provided benchmarks and recommendations for classifying an implant as an EDOF IOL as well as standardized testing criteria for evaluating performance. Although many types of EDOF technologies are being developed, there are important differences in their performance that require further testing and evaluation.
Collapse
|
15
|
Martinez-Perez C, Alvarez-Peregrina C, Villa-Collar C, Arance-Gil A, Sánchez-Tena MA. Citation network analysis of the various types of multifocal intraocular lenses. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2021; 96:S0365-6691(20)30492-5. [PMID: 33495051 DOI: 10.1016/j.oftal.2020.11.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 11/16/2020] [Accepted: 11/21/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND AND OBJECTIVE The implantation of multifocal intraocular lens (IOL) has increased in recent years, allowing patients to achieve good quality vision at all distances, independence from use of glasses, and consequently, an increase in quality of life. The main purpose of this study was to analyse the links between publications and authors via citation networks, as well to as identify the different research areas and determine the most cited publications. MATERIAL AND METHODS The publication search was performed through the Web of Science database, using the terms «Multifocal intraocular lens», «Bifocal intraocular lens», «Trifocal intraocular lens», «Diffractive intraocular lens», «Refractive intraocular lens», «Accommodative intraocular lens» and «Extended depth of focus intraocular lens», for a time interval from 1989 to August 2020. The software used to analyse the publications was the Citation Network Explorer. RESULTS A total of 1293 publications were found, with 11730 citations generated in the network, and 2019 had the highest number of publications of any year. The most cited publication was «European multicenter study of the AcrySof ReSTOR apodized diffractive intraocular lens» by Kohnen et al., published in 2006. Four groups about different research areas in this field were found using the Clustering functionality: visual quality, IOL designs, ocular aberrations, or defocus curves. CONCLUSIONS The citation network offers an objective and comprehensive analysis of the main articles on the different designs and classes of multifocal IOL.
Collapse
Affiliation(s)
- C Martinez-Perez
- Facultad de Ciencias Biomédicas y de la Salud, Universidad Europea de Madrid, Madrid, España.
| | - C Alvarez-Peregrina
- Facultad de Ciencias Biomédicas y de la Salud, Universidad Europea de Madrid, Madrid, España
| | - C Villa-Collar
- Facultad de Ciencias Biomédicas y de la Salud, Universidad Europea de Madrid, Madrid, España
| | - A Arance-Gil
- Hospital Universitario HM Montepríncipe, Madrid, España
| | - M A Sánchez-Tena
- Facultad de Ciencias Biomédicas y de la Salud, Universidad Europea de Madrid, Madrid, España
| |
Collapse
|
16
|
Ramamurthy D, Vasavada A, Padmanabhan P, Reddy JC, Shetty N, Dey A, Sudhir RR. Clinical Outcomes After Bilateral Implantation of a Trifocal Presbyopia-Correcting Intraocular Lens in an Indian Population. Clin Ophthalmol 2021; 15:213-225. [PMID: 33519183 PMCID: PMC7837564 DOI: 10.2147/opth.s279001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2020] [Accepted: 11/15/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the effectiveness and safety of a presbyopia-correcting trifocal intraocular lens (IOL), AcrySof® IQ PanOptix® (TFNT00), in an Indian population. Patients and Methods This prospective, multicenter, observational, single-arm, post-marketing study included 67 patients undergoing cataract surgery with bilateral implantation of TFNT00 across five Indian sites. Postoperative outcomes were assessed at 3 months after second eye surgery. Effectiveness outcomes included: mean binocular and monocular visual acuity (VA) at distance (4 m), intermediate (60 cm), and near (40 cm); binocular defocus curve; manifest refraction; and subjective symptom questionnaire evaluation. Safety outcomes included the rate of ocular adverse events and mesopic contrast sensitivity. Results Mean binocular and monocular distance-corrected and uncorrected VAs of 0.1 logMAR or better (approximately 20/25 Snellen) were achieved at distance, intermediate, and near. Overall, ≥70% of patients achieved binocular 0.1 logMAR vision or better across all distances. TFNT00 maintained a mean VA of 0.1 logMAR or better at the defocus range of +0.5 diopters (D) to –2.5 D (200 cm to 40 cm). The subjective symptom questionnaire-assessed frequency of halo visual disturbances was low at Month 3; halos were reported “none of the time” to “only some of the time” in 86.6% of patients. The large majority of patients (98.5%) were “satisfied” or “very satisfied” with their near, intermediate, and distance vision at Month 3, and ≥94.0% of patients reported spectacle independence for tasks at all distances. The adverse event rate was low; no patients discontinued due to an adverse event. Conclusion TFNT00 provided a continuous range of vision of 20/25 or better for distance to near and performed effectively at an intermediate functional distance of 60 cm, resulting in high levels of spectacle independence and patient satisfaction. TFNT00 demonstrated a good safety profile and a low post-operative frequency of halo visual disturbances.
Collapse
Affiliation(s)
| | | | | | | | - Naren Shetty
- Narayana Nethralaya Eye Hospital, Rajajinagar, Bangalore, India
| | - Arindam Dey
- Alcon Laboratories (India) Private Ltd, Bangalore, India
| | | |
Collapse
|
17
|
Comparison of Post-Cataract Surgery Visual Outcomes and Quality of Life in Patients Bilaterally Implanted with Multifocal Intraocular Lenses. Ophthalmol Ther 2020; 10:101-113. [PMID: 33245545 PMCID: PMC7886923 DOI: 10.1007/s40123-020-00321-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 11/07/2020] [Indexed: 11/25/2022] Open
Abstract
Introduction The present study compared visual outcomes in eyes with bilateral implantation of two multifocal intraocular lenses (MFIOLs)—the Eyecryl™ ACTV diffractive multifocal IOL (group 1) and AcrySof® IQ ReSTOR® multifocal IOL (group 2). Methods This was a prospective, two-group observational longitudinal study of 118 eyes from 59 patients conducted at Laxmi Eye Institute, Panvel, India. We evaluated the patients at 1, 3, and 6 months. We assessed visual acuity, contrast sensitivity, higher-order aberrations, reading speed, defocus curve, stereopsis, quality of life (QOL), and adverse events in these participants. Results The median (interquartile range) best-corrected distance visual acuity was 0.18 (0, 0.18) in group 1 and 0.18 (0, 0.18) in group 2 at 1, 3, and 6 months; the difference was not statistically significant (p = 0.48). The binocular defocus curve in both groups showed two peaks at 0.0 to −0.5 D and at −2.5 D. The mean (95% confidence interval) critical print size was significantly different between groups 1 and 2 at low illumination (0.918 [0.905, 0.931] vs 1.154 [1.128, 1.180]; p = 0.004). Contrast sensitivity was significantly better in group 1 under mesopic conditions but not under scotopic conditions. Though total QOL did not differ significantly between groups, the psychosocial quality of life was significantly better in group 1. About 23% of patients in group 2 reported unwanted images, compared with 0% in group 1 (p = 0.01). Conclusion We found that the Eyecryl and AcrySof groups were comparable for best-corrected visual acuity, photopic contrast sensitivity, defocus curve, reading parameters, stereopsis, and quality of vision. However, the Eyecryl group had better mesopic contrast and a lower proportion of unwanted images. Psychosocial quality of life was significantly better in the Eyecryl group; however, satisfaction was similar between groups. The cost of one of the lenses is less than the other. Thus, individuals with limited resources may opt for the Eyecryl™ ACTV, with similar visual outcomes.
Collapse
|
18
|
Modi S, Lehmann R, Maxwell A, Solomon K, Cionni R, Thompson V, Horn J, Caplan M, Fisher B, Hu JG, Yeu E. Visual and Patient-Reported Outcomes of a Diffractive Trifocal Intraocular Lens Compared with Those of a Monofocal Intraocular Lens. Ophthalmology 2020; 128:197-207. [PMID: 33004211 DOI: 10.1016/j.ophtha.2020.07.015] [Citation(s) in RCA: 38] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2020] [Revised: 07/02/2020] [Accepted: 07/07/2020] [Indexed: 10/23/2022] Open
Abstract
PURPOSE To evaluate the effectiveness and safety of a trifocal intraocular lens (IOL), the TFNT00 (Alcon, Fort Worth, TX), versus a monofocal IOL, the SN60AT (Alcon). DESIGN Food and Drug Administration-approved, prospective, multicenter, nonrandomized, parallel-group, assessor-masked, confirmatory trial. PARTICIPANTS Patients enrolled were 22 years of age or older with a diagnosis of bilateral cataract with planned removal by phacoemulsification with a clear corneal incision. METHODS Consented participants selected their preferred IOL, which was implanted sequentially into each eye of patients meeting eligibility criteria. MAIN OUTCOME MEASURES The coprimary effectiveness outcomes were mean photopic monocular best-corrected distance visual acuity (BCDVA; 4 m) and distance-corrected near visual acuity (DCNVA; 40 cm) at 6 months after surgery. Secondary effectiveness outcomes included mean monocular distance-corrected intermediate visual acuity (DCIVA; 66 cm) and proportion of participants responding "never" to question 1 of the Intraocular Lens Satisfaction questionnaire (regarding frequency of spectacle use in the past 7 days). Safety outcomes included frequency of "severe" and "most bothersome" visual disturbances. RESULTS Two hundred forty-three patients underwent cataract surgery with bilateral implantation of the TFNT00 (n = 129) or SN60AT (n = 114) and were followed up for 6 months. Noninferiority of TFNT00 to SN60AT in mean photopic monocular BCDVA (95% upper confidence limit of the difference was <0.1 logarithm of the minimum angle of resolution [logMAR] margin), and superiority in mean photopic monocular DCNVA (difference of 0.42 logMAR; P < 0.001) and DCIVA (difference of 0.26 logMAR; P < 0.001) were demonstrated. The proportion of patients never requiring glasses overall was superior for TFNT00 versus SN60AT (80.5% and 8.2%, respectively). Starbursts, halos, and glare were the most frequently rated severe symptoms with TFNT00; however, less than 5% of patients were very bothered at month 6. CONCLUSIONS The TFNT00 exhibited superior monocular DCNVA and DCIVA to a spherical monofocal IOL, with comparable monocular BCDVA. Binocular visual acuity was 20/25 or better for distance to near (+0.5 D to -2.5 D), resulting in high levels of spectacle independence. Less than 5% of patients were very bothered by the photic visual disturbances associated with the TFNT00 at 6 months after surgery.
Collapse
Affiliation(s)
| | | | | | - Kerry Solomon
- Carolina Eyecare Physicians, LLC, Mount Pleasant, South Carolina
| | | | | | | | | | - Bret Fisher
- Eye Center of North Florida, Panama City, Florida
| | - Jerry G Hu
- Texas Eye and Laser Center, Hurst, Texas
| | | |
Collapse
|
19
|
Tanabe H, Tabuchi H, Shojo T, Yamauchi T, Takase K. Comparison of visual performance between monofocal and multifocal intraocular lenses of the same material and basic design. Sci Rep 2020; 10:15490. [PMID: 32968124 PMCID: PMC7511318 DOI: 10.1038/s41598-020-72473-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Accepted: 09/02/2020] [Indexed: 02/06/2023] Open
Abstract
To compare the visual performance of a monofocal intraocular lens (IOL) (ZCB00) and a multifocal IOL (ZMB00) of the same material and basic design, we evaluated postoperative parameters at 10 weeks after the last surgery in cataract patients who underwent bilateral ZCB00 or ZMB00 implantation from December 13, 2010, to July 29, 2019, with the right and left lenses implanted within 3 months of each other. The study enrolled 2,230 eyes of 1,115 patients. The monofocal group comprised 904 eyes of 452 patients (72.3 ± 6.8 years; females/males, 268/184), and the multifocal group comprised 1,326 eyes of 663 patients (67.0 ± 7.8 years; females/males, 518/145). Contrast sensitivity (4.0/2.5/1.6/1.0/0.7 degrees), contrast sensitivity with glare (1.6/1.0/0.7 degrees), and the VFQ-25 score for driving at night were significantly better in the monofocal group (p < 0.00068, Wald test). Uncorrected intermediate/near visual acuity and near spectacle independence were significantly better in the multifocal group (p < 0.00068, Wald test). The two IOL groups had different characteristics in terms of contrast sensitivity, night-time driving, uncorrected intermediate/near visual acuity and near spectacle independence.
Collapse
Affiliation(s)
- Hirotaka Tanabe
- Department of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.
| | - Hitoshi Tabuchi
- Department of Ophthalmology, Tsukazaki Hospital, Himeji, Japan.,Department of Technology and Design Thinking for Medicine, Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan
| | - Tomohiro Shojo
- Department of Ophthalmology, Tsukazaki Hospital, Himeji, Japan
| | | | - Kosuke Takase
- Department of Ophthalmology, Tsukazaki Hospital, Himeji, Japan
| |
Collapse
|
20
|
Defocus curves of 4 presbyopia-correcting IOL designs: Diffractive panfocal, diffractive trifocal, segmental refractive, and extended-depth-of-focus. J Cataract Refract Surg 2020; 45:1625-1636. [PMID: 31706517 DOI: 10.1016/j.jcrs.2019.07.014] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2019] [Revised: 07/02/2019] [Accepted: 07/03/2019] [Indexed: 01/10/2023]
Abstract
PURPOSE To evaluate the defocus curves of 4 presbyopia-correcting intraocular lenses (IOLs). SETTING Department of Ophthalmology, Goethe University, Frankfurt, Germany. DESIGN Prospective case series. METHODS Patients included in the study had bilateral surgery with implantation of diffractive panfocal, diffractive trifocal, segmental refractive (SegRef), or extended-depth-of-focus (EDOF) presbyopia-correcting IOLs. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, uncorrected intermediate and near visual acuities, distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuities, defocus curve, and spectacle independence were measured. RESULTS The UDVA and CDVA were not significantly different between groups (P > .05); however, the EDOF group had worse near CDVA (P < .001). The trifocal and EDOF groups showed better DCIVA than the panfocal and SegRef group at 80 cm (P < .001); the EDOF and panfocal groups had comparable DCIVA at 60 cm (P > .05). Defocus curves showed no significant between-group differences from 4 m to 2 m (P > .05). The EDOF group had better visual acuity from 1 m to 67 cm than the trifocal and SegRef groups and better visual acuity than the panfocal group at 1 m (P > .05). Compared with the other IOLs, the panfocal IOL yielded significantly better visual acuity at 50 cm (P < .001) and the EDOF IOL worse visual acuity at 40 cm (P < .01). There was a significant difference in spectacle independence between the panfocal group and EDOF group (P < .05) but no difference between the other groups. CONCLUSIONS The 4 IOLs provided equally good CDVA. The EDOF IOL yielded slightly better DCIVA but worse DCNVA than the other IOLs. Only the panfocal IOL gave better DCIVA at 50 cm.
Collapse
|
21
|
Kim TI, Chung TY, Kim MJ, Lee K, Hyon JY. Visual outcomes and safety after bilateral implantation of a trifocal presbyopia correcting intraocular lens in a Korean population: a prospective single-arm study. BMC Ophthalmol 2020; 20:288. [PMID: 32669090 PMCID: PMC7362483 DOI: 10.1186/s12886-020-01549-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Accepted: 07/06/2020] [Indexed: 11/13/2022] Open
Abstract
Background To investigate the 3-month postoperative performance and safety after implantation of a trifocal intraocular lens (IOL) in a Korean population. Methods This was a clinical, prospective, multicenter, single-arm study. Forty-four subjects (88 eyes) with bilateral cataract with expected postoperative corneal astigmatism of < 1.00 diopter (D) and no ocular disease or eye condition underwent bilateral implantation of the AcrySof IQ® PanOptix IOL (TFNT00). Postoperative examination at 3 months included binocular defocus curve; binocular best corrected distance visual acuity (BCDVA); monocular/binocular uncorrected VA (UCVA) at distance (4 m), intermediate (60 cm), and near (40 cm); contrast sensitivity under photopic conditions with/without glare; and subjective outcomes, including satisfaction and spectacle independence. Results Binocular defocus curve at 3 months after bilateral implantation showed VA of 0.1 logMAR or better from + 0.5 D through − 2.5 D. Binocular BCDVA mean ± SD at 4 m was − 0.05 ± 0.07 logMAR. Binocular and monocular UCVA was 0.03 ± 0.1 and 0.08 ± 0.12 logMAR (4 m), − 0.00 ± 0.11 and 0.05 ± 0.13 logMAR (60 cm), and 0.03 ± 0.12 and 0.09 ± 0.13 logMAR (40 cm), respectively. Contrast sensitivity with glare was 1.67 ± 0.13, 1.91 ± 0.17, 1.54 ± 0.21, and 1.14 ± 0.20 log units at 3, 6, 12, and 18 cycles/degree, respectively. At near and intermediate distances, 84 and 77% of subjects reported good/excellent satisfaction, and 84 and 91% of subjects reported spectacle independence, respectively. Conclusions In a Korean population, visual performance of the trifocal TFNT00 IOL 3 months postoperatively was < 0.1 logMAR for binocular UCVA at all distances, with high subject satisfaction and spectacle independence. Trial registration www.ClinicalTrials.gov (NCT03268746). Registered August 31, 2017.
Collapse
Affiliation(s)
- Tae-Im Kim
- Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea
| | - Tae-Young Chung
- Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea
| | | | | | - Joon Young Hyon
- Department of Ophthalmology, Seoul National University Bundang Hospital, 82 Gumi-ro 173beon-gil, Bundang-gu, Seongnam, 13620, South Korea.
| |
Collapse
|
22
|
Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens. J Ophthalmol 2020; 2020:7923045. [PMID: 32377423 PMCID: PMC7189321 DOI: 10.1155/2020/7923045] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2019] [Revised: 01/15/2020] [Accepted: 02/10/2020] [Indexed: 02/07/2023] Open
Abstract
Purpose To compare the short-term visual outcomes and intraocular optical performance of a rotationally asymmetric multifocal intraocular lens (MIOL) (SBL-3, Lenstec, Inc., Christ Church, Barbados) and an apodized diffractive MIOL (the Acrysof IQ ResTOR SN6AD1, Alcon Laboratories, Inc., Fort Worth, Texas, United States). Methods A prospective, comparative, nonrandomized, and single-center study. Sixty-eight age-related cataract patients (81 eyes) after phacoemulsification cataract surgery and in-the-bag MIOL implantation were enrolled. Thirty-eight eyes received SBL-3, and 43 eyes received SN6AD1. Ophthalmological evaluation included uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), modulation transfer function (MTF), Strehl ratio (SR), intraocular aberrations (4 mm optical zone), and defocus curve at 3 months postoperatively. The Chinese version of the visual function index-14 (VF-12-CN) and spectacle independence were assessed in all patients. Results There was no statistically significant difference between groups in postoperative UDVA (p = 0.186). Postoperative UIVA and UNVA were significantly better for the SBL-3 group than for the SN6AD1 group (p < 0.01). Statistically significant differences were revealed in defocus levels from –3.50 D to −4.00 D with better visual acuities for the SBL-3 group (p < 0.01). For intraocular optical quality outcomes, statistically significant differences between groups were observed in RMS of intraocular total aberrations, coma, and trefoil high-order aberrations, presenting significantly higher values of these parameters in the eyes of the SBL-3 group (p < 0.01). Statistically significant differences were revealed in the MTF values at spatial frequencies of 5 and 10 cycles/degree between groups. There were no significant differences in scores of VF-12-CN, and spectacle independence between the groups (p > 0.05). Conclusions Both MIOLs were able to successfully restore visual function after cataract surgery. SBL-3 provided better UIVA and UNVA with a wider range of intermediate vision.
Collapse
|
23
|
Kim EC, Na KS, Kim HS, Hwang HS. How does the world appear to patients with multifocal intraocular lenses?: a mobile model eye experiment. BMC Ophthalmol 2020; 20:180. [PMID: 32375711 PMCID: PMC7201983 DOI: 10.1186/s12886-020-01446-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Accepted: 04/23/2020] [Indexed: 12/16/2022] Open
Abstract
Background To show how the world appear to patients with multifocal intraocular lens (IOL) using a novel mobile model eye. Methods The mobile model eye was composed of an artificial cornea, IOL, IOL chamber, and a camera. A monofocal IOL (Tecnis monofocal IOL) and two diffractive multifocal IOL (ReSTOR, Tecnis multifocal IOL) were used in the study. We went outside to take a picture of the scenery. At night, we stood on a road and took pictures to see how the traffic lights and headlights of cars looked. For an indoor analysis, we approached the Early Treatment Diabetic Retinopathy Study (ETDRS) chart to the model eye from a distance of 95 cm to check the multifocal function of the lenses. In the car, we took pictures of the street and a cell phone in turn to check the multifocal function of the lenses. Results Two multifocal IOLs showed definite multifocal function. Far objects appeared either similarly clear or slightly hazier (depending on the IOL model) than those with the monofocal IOL. In the night vision, there was a mild or severe halo around light sources compared to those with the monofocal IOL. Conclusion We believe that this mobile model eye can be used to evaluate how the real world appear to a patient with a multifocal IOL, to explain multifocal function of the IOLs, and possible complications in the patients, before performing a surgery.
Collapse
Affiliation(s)
- Eun Chul Kim
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Kyung-Sun Na
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Hyun Seung Kim
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Ho Sik Hwang
- Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea. .,Department of Ophthalmology, Yeouido St. Mary's Hospital, The Catholic University of Korea, 10, 63-ro, Yeongdeungpo-gu, Seoul, 07345, Republic of Korea.
| |
Collapse
|
24
|
Ophthalmologic Applications. Biomater Sci 2020. [DOI: 10.1016/b978-0-12-816137-1.00072-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
25
|
Kim BH, Hyon JY, Kim MK. Effects of Bifocal versus Trifocal Diffractive Intraocular Lens Implantation on Visual Quality after Cataract Surgery. KOREAN JOURNAL OF OPHTHALMOLOGY 2019; 33:333-342. [PMID: 31389209 PMCID: PMC6685823 DOI: 10.3341/kjo.2019.0001] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 04/24/2019] [Accepted: 05/08/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare the effects of bifocal versus trifocal diffractive intraocular lens (IOL) implantation on visual quality after phacoemulsification in patients with cataracts. Methods Eighty-eight eyes from 63 patients were analyzed. Trifocal (AT LISA tri 839MP), bifocal (AcrySof IQ ReSTOR) and bifocal (Tecnis MF ZLB00) IOLs were implanted into 53, 18, and 17 eyes, respectively. Uncorrected distance, intermediate and near visual acuity, refractive errors, contrast sensitivity, and patient satisfaction were measured at 1 week and 1 month after surgery. Refractive error was converted to a spherical equivalent and compared to predicted refraction calculated by IOL calculation formulas. Results Uncorrected distance, intermediate, and near visual acuity did not differ significantly between groups. One month after surgery, the mean refractive errors were −0.07 diopters (D) in the AT LISA tri 839MP group, +0.18 D in the AcrySof IQ ReSTOR group, and +0.31 D in the Tecnis MF ZLB00 group (p < 0.001). The predictive accuracy of IOL calculation formulas did not differ between groups. Contrast sensitivity, satisfaction, and spectacle independence in the trifocal group were comparable with those of the two bifocal groups. Conclusions Trifocal IOL and two different types of bifocal IOL implantation were all effective for improving visual quality, although refractive error in patients with trifocal IOL shows myopic tendencies.
Collapse
Affiliation(s)
- Bo Hee Kim
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea
| | - Joon Young Hyon
- Department of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea
| | - Mee Kum Kim
- Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea.,Laboratory of Ocular Regenerative Medicine and Immunology, Seoul Artificial Eye Center, Seoul National University Hospital Biomedical Research Institute, Seoul, Korea.
| |
Collapse
|
26
|
Comparison of visual outcomes between bilateral trifocal intraocular lenses and combined bifocal intraocular lenses with different near addition. Jpn J Ophthalmol 2019; 63:429-436. [DOI: 10.1007/s10384-019-00693-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Accepted: 08/30/2019] [Indexed: 10/25/2022]
|
27
|
Relations between patient personality and patients' dissatisfaction after multifocal intraocular lens implantation: clinical study based on the five factor inventory personality evaluation. Eye (Lond) 2019; 34:717-724. [PMID: 31541219 DOI: 10.1038/s41433-019-0585-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Revised: 04/14/2019] [Accepted: 08/22/2019] [Indexed: 11/09/2022] Open
Abstract
To assess the level of visual function and the influence of personality traits on patients' (pts) satisfaction with the visual function following the four different MIOL implantation. METHODS We evaluated the visual outcomes over a 6 months follow-up period after cataract surgery with bilateral implantation of four different multifocal IOLs. The spectacle independence, photic phenomena, the influence of personality traits on patients' satisfaction with the visual function were assessed. RESULTS A total of 170 eyes of 85 pts were included. There was no statistically significant difference in UDVA (F = 1.6 p = 0.177) and CNVA (F = 1.2 p = 0.30) between the groups 6 months after the surgery. The ReSTOR group had a worse CDVA than the M-flex (p = 0.019) and TECNIS (p = 0.005) groups. The ReSTOR and AT.LISAtri groups had a statistically significantly better UNVA than the M-flex (p = 0.020 and p = 0.013) and TECNIS groups (p = 0.001 both). The independence on spectacles for near distance was from 71.8% (in M-flex group) to 100% (in ReSTOR). The answers of the pts with the prevailing neurotic personality type contradicted the answers given by the pts with other prevailing personality types (p < 0.01). CONCLUSIONS MIOL implantation helped ensure better postoperative visual acuity, but some pts were unhappy with the postoperative outcomes. It was established that the subjective satisfaction or dissatisfaction of patients after MIOL implantation is related to certain personality traits: pts with neuroticism as the dominant personality trait were least happy with the postoperative outcomes; pts with conscientiousness and agreeableness as dominant personality traits demonstrated the highest satisfaction with the postoperative outcomes.
Collapse
|
28
|
Update on the Use of Premium Intraocular Lenses in Glaucoma. CURRENT OPHTHALMOLOGY REPORTS 2019. [DOI: 10.1007/s40135-019-00215-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
29
|
Bissen-Miyajima H, Ota Y, Nakamura K, Hirasawa M, Minami K. Binocular Visual Function With Staged Implantation of Diffractive Multifocal Intraocular Lenses With Three Add Powers. Am J Ophthalmol 2019; 199:223-229. [PMID: 30552894 DOI: 10.1016/j.ajo.2018.11.020] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 11/16/2018] [Accepted: 11/28/2018] [Indexed: 11/19/2022]
Abstract
PURPOSE To evaluate the binocular visual function and depth of focus after staged implantation of diffractive multifocal intraocular lenses (MIOLs) with 3 different add powers following cataract removal. DESIGN Prospective comparative case series. METHODS Setting: Institutional. STUDY POPULATION Both eyes of 56 patients that underwent staged implantation of bifocal IOLs. INTERVENTION In the first eye, MIOLs with a +4.0-diopter (D) add power were implanted. Based on outcomes at 1 week postoperatively and patient preference for near vision, 1 of 3 near add powers-+4.0 D (group MM), +3.25 D (group ML), or +2.75 D (group MK)-was implanted in the fellow eye. MAIN OUTCOME MEASURE(S) Three months postoperatively, the binocular uncorrected and distance-corrected visual acuities (BUCVA and BDCVA, respectively) at 5.0, 1.0, 0.5, 0.4, and 0.3 meters; binocular defocus curves; contrast sensitivity; and near stereopsis were measured. RESULTS The MM, ML, and MK groups included 21, 18, and 17 patients, respectively. The mean BUCVA in the MM group was significantly (P = .003) worse than that in the MK group at 0.5 meter. The BDCVAs at 0.5 meter in the ML and MK groups were significantly (P < .02) better than that in the MM group. The defocus curves with the -2.0 D refraction differed significantly (P < .001) between the MM and MK groups. The binocular contrast sensitivity and stereopsis values did not differ significantly. CONCLUSIONS Staged implantation of different add powers obtained better binocular intermediate visual acuity without degradation of visual function.
Collapse
Affiliation(s)
| | - Yuka Ota
- Department of Ophthalmology, Tokyo Dental Collage Suidobashi Hospital, Tokyo, Japan
| | - Kunihiko Nakamura
- Department of Ophthalmology, Tokyo Dental Collage Suidobashi Hospital, Tokyo, Japan
| | - Manabu Hirasawa
- Department of Ophthalmology, Tokyo Dental Collage Suidobashi Hospital, Tokyo, Japan
| | - Keiichiro Minami
- Department of Ophthalmology, Tokyo Dental Collage Suidobashi Hospital, Tokyo, Japan
| |
Collapse
|
30
|
Hyun J. Surgical treatment of presbyopia I. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION 2019. [DOI: 10.5124/jkma.2019.62.12.616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Joo Hyun
- Saevit Eye Hospital, Goyang, Korea
| |
Collapse
|
31
|
Park SH, Kim SI, Ahn JH, Shin JH, Kim SJ, Lee JE. Clinical Outcomes of Patients Implanted with Bifocal and Extended Depth of Focus Intraocular Lenses. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2019. [DOI: 10.3341/jkos.2019.60.9.835] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Su Hwan Park
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Sung Il Kim
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Jung Hyo Ahn
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Jong Hoon Shin
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Su Jin Kim
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| | - Ji Eun Lee
- Department of Ophthalmology, Pusan National University Yangsan Hospital, Pusan National University School of Medicine, Yangsan, Korea
- Research Institute for Convergence of Biomedical Science and Technology, Pusan National University Yangsan Hospital, Yangsan, Korea
| |
Collapse
|
32
|
Femtosecond laser–assisted cataract surgery versus conventional phacoemulsification: Refractive and aberrometric outcomes with a diffractive multifocal intraocular lens. J Cataract Refract Surg 2019; 45:21-27. [DOI: 10.1016/j.jcrs.2018.08.032] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 08/07/2018] [Accepted: 08/14/2018] [Indexed: 11/20/2022]
|
33
|
Teshigawara T, Meguro A, Yabuki K, Hata S, Mizuki N. Visual performance of the intraindividual implantation of a trifocal intraocular lens in the bag and a +4.0 D bifocal intraocular lens in the sulcus with optic capture created by femtosecond laser-assisted cataract surgery. Int Med Case Rep J 2018; 11:251-257. [PMID: 30323689 PMCID: PMC6173176 DOI: 10.2147/imcrj.s176095] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
At present, only one design is available for trifocal intraocular lens (IOL); unfortunately, this particular design is not suitable for implantation in the sulcus with optic capture when posterior capsule rupture (PCR) occurs. Although three-piece bifocal IOLs can be implanted in the sulcus, this form of IOL can be vulnerable to tilt and decentration, thus causing aberration and photopic phenomena, such as halos and glares. However, visual axis centered optic capture using femtosecond laser-assisted cataract surgery (FLACS) is able to manage such complex operations. In the present study, we implanted a three-piece +4.0 D bifocal IOL into the sulcus of a patient who experienced PCR using optic capture and FLACS following the straightforward implantation of a one-piece trifocal IOL in the other eye. Defocus curves showed that the weakness of the trifocal IOL (nearest distances) was compensated for by the strength of the +4.0 D bifocal IOL, whereas the weakness of the +4.0 D bifocal IOL (middle distance) was compensated for by the strength of the trifocal IOL. Therefore, this combination provided the patient with a wider range of depth of focus. The contrast sensitivity in both eyes was within the normal range. Photopic phenomena were comparable with the bilateral implantation of the trifocal IOL. Anterior segment optical coherence tomography showed that tilt and decentration in the trifocal IOL implanted in the bag was significantly higher than the +4.0 D bifocal IOL implanted in the visual axis centered optic capture. This case showed that the intraindividual implantation of a single-piece trifocal IOL in the bag and a three-piece +4.0 D bifocal IOL in the sulcus, using a combination of optic capture and FLACS, is promising particularly in cases of PCR and can provide a wider range of vision without losing visual quality.
Collapse
Affiliation(s)
- Takeshi Teshigawara
- Yokosuka Chuoh Eye Clinic, Yokosuka, Kanagawa, Japan, .,Tsurumi Chuoh Eye Clinic, Yokohama, Kanagawa, Japan, .,Department of Ophthalmology, Yokohama City University School of Medicine, Yokohama, Kanagawa, Japan,
| | - Akira Meguro
- Department of Ophthalmology, Yokohama City University School of Medicine, Yokohama, Kanagawa, Japan,
| | - Kazuro Yabuki
- Department of Ophthalmology, Saiseikai Yokohamashi Nanbu Hospital, Yokohama, Kanagawa, Japan
| | | | - Nobuhisa Mizuki
- Department of Ophthalmology, Yokohama City University School of Medicine, Yokohama, Kanagawa, Japan,
| |
Collapse
|
34
|
Wolffsohn JS, Davies LN. Presbyopia: Effectiveness of correction strategies. Prog Retin Eye Res 2018; 68:124-143. [PMID: 30244049 DOI: 10.1016/j.preteyeres.2018.09.004] [Citation(s) in RCA: 132] [Impact Index Per Article: 22.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2018] [Revised: 09/14/2018] [Accepted: 09/18/2018] [Indexed: 01/04/2023]
Abstract
Presbyopia is a global problem affecting over a billion people worldwide. The prevalence of unmanaged presbyopia is as high as 50% of those over 50 years of age in developing world populations, due to a lack of awareness and accessibility to affordable treatment, and is even as high as 34% in developed countries. Definitions of presbyopia are inconsistent and varied, so we propose a redefinition that states "presbyopia occurs when the physiologically normal age-related reduction in the eye's focusing range reaches a point, when optimally corrected for distance vision, that the clarity of vision at near is insufficient to satisfy an individual's requirements". Strategies for correcting presbyopia include separate optical devices located in front of the visual system (reading glasses) or a change in the direction of gaze to view through optical zones of different optical powers (bifocal, trifocal or progressive addition spectacle lenses), monovision (with contact lenses, intraocular lenses, laser refractive surgery and corneal collagen shrinkage), simultaneous images (with contact lenses, intraocular lenses and corneal inlays), pinhole depth of focus expansion (with intraocular lenses, corneal inlays and pharmaceuticals), crystalline lens softening (with lasers or pharmaceuticals) or restored dynamics (with 'accommodating' intraocular lenses, scleral expansion techniques and ciliary muscle electrostimulation); these strategies may be applied differently to the two eyes to optimise the range of clear focus for an individual's task requirements and minimise adverse visual effects. However, none fully overcome presbyopia in all patients. While the restoration of natural accommodation or an equivalent remains elusive, guidance is given on presbyopic correction evaluation techniques.
Collapse
Affiliation(s)
- James S Wolffsohn
- Ophthalmic Research Group, Life and Health Sciences, Aston University, Birmingham, B4 7ET, UK.
| | - Leon N Davies
- Ophthalmic Research Group, Life and Health Sciences, Aston University, Birmingham, B4 7ET, UK
| |
Collapse
|
35
|
Poyales F, Garzón N, Pizarro D, Cobreces S, Hernández A. Stability and visual outcomes yielded by three intraocular trifocal lenses with same optical zone design but differing material or toricity. Eur J Ophthalmol 2018; 29:417-425. [PMID: 30198329 DOI: 10.1177/1120672118795065] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
PURPOSE To compare rotational stability, centration and visual outcomes provided by three trifocal lens models that have the same optical zone design but different material, composition, and/or toricity. METHODS The study included 78 patients with symmetric bilateral intraocular lens implantation. The lenses under evaluation were trifocal intraocular lenses made of hydrophilic acrylic material: a spherical lens 26% hydrophilic acrylic (POD FineVision), a similar lens but having a toric design (POD Toric FineVision), and a trifocal lens 25% hydrophilic acrylic material (FineVision/MicroF). Moreover, the lenses share the same optical zone design. The lenses' rotational stability and centration were measured by means of the PIOLET software, which relies on recording and image processing techniques to determine lens rotation and centration based on slit-lamp images. We also assessed patients' visual quality by means of 25, 40, and 80 cm VA tests. RESULTS The best centration results were achieved with the POD Toric FineVision model, although the differences were not statistically significant. As for lens rotation, it was below 5° in all cases under study. Regarding VA, all subjects attained at least 0.3 logMAR for far distance uncorrected VA, at 80 cm VA was about 0.2 logMAR, at 40 cm it was above 0.15 logMAR, and at 25 cm it was about 0.3 logMAR for both lens types. CONCLUSION All three intraocular lens models yield excellent visual results at far, near as well as intermediate distances. The POD FineVision and POD Toric FineVision models, with double C-loop design, yielded the best results centration-wise and rotation-wise. Differences had no clinical relevance.
Collapse
Affiliation(s)
| | | | - Daniel Pizarro
- 2 Department of Electronics, University of Alcalá, Madrid, Spain
| | | | - Adolfo Hernández
- 1 IOA Madrid Innova Ocular, Madrid, Spain.,2 Department of Electronics, University of Alcalá, Madrid, Spain
| |
Collapse
|
36
|
Trivizki O, Smadja D, Mimouni M, Levinger S, Levinger E. Bioptics for high hyperopia with combined multifocal intraocular lens implantation and excimer ablation in young patients. Eur J Ophthalmol 2018; 29:426-430. [PMID: 30175611 DOI: 10.1177/1120672118797281] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To analyze the visual and refractive outcome of the bioptics procedure combining multifocal intraocular lens implantation and excimer laser surgery in young patients with high hyperopic eyes not suitable for a single surgical procedure. METHODS This retrospective case series included 10 eyes of five patients (age range 18-30 years) with high hyperopia (spherical equivalent +8.51 ± 0.85 diopters (D)). They had been treated with serial multifocal intraocular lens implantation followed 6 weeks later by laser in situ keratomileusis for residual hyperopia. Uncorrected distance visual acuity, uncorrected near visual acuity, corrected distance visual acuity, corrected near visual acuity, and manifest refraction were evaluated before surgeries, after multifocal intraocular lens implantation, and 3 months post laser in situ keratomileusis. RESULTS No patients were lost to follow-up (6 months). The mean spherical equivalent decreased to +2.05 ± 1.33 D after multifocal intraocular lens implantation and to -0.10 ± 0.58 D after the laser in situ keratomileusis procedure. Success of the procedures was determined by uncorrected visual acuity. LogMAR uncorrected distance visual acuity improved by a total of more than six lines from 1.05 ± 0.18 LogMAR to 0.46 ± 0.12 LogMAR post multifocal intraocular lens implantation and to 0.15 ± 0.06 LogMAR after both surgeries. The LogMAR uncorrected near visual acuity increased by 0.81 ± 0.82 LogMAR after lens implantation due to loss of accommodation, and all eyes reached a LogMAR of 0 at 1 month postoperatively following laser in situ keratomileusis. CONCLUSIONS A bioptics approach involving multifocal intraocular lens followed 6 weeks later by a laser in situ keratomileusis procedure for the correction of very high hyperopia enabled the resolution of the residual refractive error in young very high hyperopic patients.
Collapse
Affiliation(s)
- Omer Trivizki
- 1 Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,2 Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - David Smadja
- 1 Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,2 Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.,3 Enaim Refractive Surgery Center, Jerusalem, Israel
| | - Michael Mimouni
- 4 Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel.,5 Ruth Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel
| | | | - Eliya Levinger
- 1 Department of Ophthalmology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,2 Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.,3 Enaim Refractive Surgery Center, Jerusalem, Israel
| |
Collapse
|
37
|
Kohnen T, Hemkeppler E, Herzog M, Schönbrunn S, DeLorenzo N, Petermann K, Böhm M. Visual Outcomes After Implantation of a Segmental Refractive Multifocal Intraocular Lens Following Cataract Surgery. Am J Ophthalmol 2018; 191:156-165. [PMID: 29684328 DOI: 10.1016/j.ajo.2018.04.011] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 04/07/2018] [Accepted: 04/12/2018] [Indexed: 10/17/2022]
Abstract
PURPOSE To evaluate visual outcomes, with particular attention to intermediate visual acuity (VA), of a segmental refractive multifocal intraocular lens (IOL) with optimized depth of focus (DoF). DESIGN Prospective, nonrandomized, noncomparative case series. METHODS Setting: Department of Ophthalmology, Goethe University, Frankfurt/Germany. Patient or Study Population: Fifty eyes (25 patients) were included. Inclusion criteria were bilateral cataract, age > 45 years, corneal astigmatism ≤ 0.75 diopter (D) postoperatively, pupil size 3-6 mm (mesopic), and center shift < 1 mm (Pentacam). Exclusion criteria were ocular surgeries, amblyopia, or potential postoperative distance-corrected VA (DCVA) > 0.3 logMAR. Intervention or Observation: Uncorrected (UCVA) and DCVA in 4 m, 80 cm, 40 cm; contrast sensitivity (CS); reading skills; defocus curve; and questionnaire on optical quality (OQ) and spectacle independence were assessed after 3 months. MAIN OUTCOME MEASURES UCVA and DCVA in 4 m, 80 cm, 40 cm; defocus curve. RESULTS UCVA was 0.05 ± 0.122 logMAR at 4 m, 0.18 ± 0.164 logMAR at 80 cm, and 0.16 ± 0.140 logMAR at 40 cm. Defocus curve testing showed, respectively, a flat monocular and binocular VA range from 0.00 to -2.00 D (-0.03 to 0.11 logMAR, -0.05 to 0.05 logMAR). Median CS under photopic and mesopic conditions without and with glare was 1.81 logCS, 1.65 logCS, 1.52 logCS, and 1.14 logCS, respectively. Reading speed at 40 cm showed a reading acuity of 0.100 logRAD with 94 words/minute. CONCLUSION This segmental multifocal IOL provides good VA at all distances (<0.20 logMAR), particularly providing good intermediate visual acuity and DoF. It showed good reading skills, OQ, and CS and high spectacle independence.
Collapse
|
38
|
Steinwender G, Schwarz L, Böhm M, Slavík-Lenčová A, Hemkeppler E, Shajari M, Kohnen T. Visual results after implantation of a trifocal intraocular lens in high myopes. J Cataract Refract Surg 2018; 44:680-685. [DOI: 10.1016/j.jcrs.2018.04.037] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2017] [Revised: 03/02/2018] [Accepted: 04/12/2018] [Indexed: 11/27/2022]
|
39
|
Yıldırım Karabağ R, Günenç Ü, Aydın R, Arıkan G, Aslankara H. Visual Results Following Implantation of a Refractive Multifocal Intraocular Lens in One Eye and a Diffractive in the Contralateral Eye. Turk J Ophthalmol 2018; 48:6-14. [PMID: 29576891 PMCID: PMC5854863 DOI: 10.4274/tjo.56588] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Accepted: 07/03/2017] [Indexed: 01/08/2023] Open
Abstract
Objectives To assess the visual outcomes in patients who underwent cataract surgery with multifocal intraocular lens (IOL) implantation using a “mix and match” approach. Materials and Methods Twenty patients (40 eyes) were involved in this prospective, nonrandomized study. Refractive multifocal IOLs (ReZoom NXG1) were implanted in patients’ dominant eyes and diffractive multifocal IOLs (Tecnis ZMA00) were implanted in their non-dominant eyes. Monocular and binocular uncorrected distance, intermediate and near visual acuity (logMAR), and contrast sensitivity levels were measured at 1, 3, and 6 months after cataract surgery. Defocus curves, reading speeds, patient satisfaction, spectacle dependence, and halo and glare symptoms were also evaluated at 6 months after the surgery. Postoperative quality of life was assessed with the Turkish version of National Eye Institute Visual Function Questionnaire-25. Results The study group comprised 8 females and 12 males with a mean age of 69.45±10.76 years (range, 31-86 years). The uncorrected distance and intermediate visual acuity levels were significantly better in the ReZoom-implanted eyes at postoperative 6 months (p=0.026 and p=0.037, respectively). There was no statistically significant difference in uncorrected near visual acuity (p>0.05). There was no statistically significant difference in contrast sensitivity, reading speed, halos, or glare between the groups (p<0.05). Mild glare/halo was reported by 40% of the subjects. The mean patient satisfaction was 95% and all patients were spectacle independent. Conclusion Mixing and matching multifocal IOLs in selected cataract patients provides excellent visual outcome, a high level of patient satisfaction, and spectacle independency.
Collapse
Affiliation(s)
| | - Üzeyir Günenç
- Dokuz Eylül University Faculty of Medicine, Department of Ophthalmology, İzmir, Turkey
| | - Rukiye Aydın
- Medipol University Faculty of Medicine, Department of Ophthalmology, İstanbul, Turkey
| | - Gül Arıkan
- Dokuz Eylül University Faculty of Medicine, Department of Ophthalmology, İzmir, Turkey
| | | |
Collapse
|
40
|
Fernández-Vega L, Madrid-Costa D, Alfonso JF, Poo-López A, Montés-Micó R. Bilateral Implantation of the Acri.LISA Bifocal Intraocular Lens in Myopic Eyes. Eur J Ophthalmol 2018; 20:83-9. [DOI: 10.1177/112067211002000111] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose To asses visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL) (Carl Zeiss Meditec) in patients with high and low–moderate myopia. Methods A total of 304 eyes of 152 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low–moderate myopia (IOL power from 15 to 20.5 D) and high myopia (IOL power from 0 to 14.5 D). Monocular and binocular best-corrected distance visual acuity (BCVA) and best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (BCIVA), and distance contrast sensitivity (OS) under photopic (85 cd/m2) and mesopic (5 cd/m2) conditions were determined. Results At the 6-month postoperative visit, there were no statistically significant differences in monocular and binocular BCVA (p=0.13 and p=0.22, respectively). Monocular and binocular BCNVA was comparable between the groups (p=0.26 and p=0.09, respectively). The mean binocular BCIVA changed significantly as a function of the distance of the test (p<0.01) in both groups, and there were no statistically significant differences between groups at any distance. Monocular and binocular CS under photopic and mesopic conditions was similar between both groups (p>0.01). Conclusions Bilateral implantation of the Acri.LISA 366D in high myopic eyes provides a satisfactory full range of vision comparable to that obtained in low–moderate myopic eyes.
Collapse
Affiliation(s)
- Luis Fernández-Vega
- Fernández-Vega Ophthalmological Institute
- Surgery Department, School of Medicine, University of Oviedo
| | - David Madrid-Costa
- Fernández-Vega Ophthalmological Institute
- Optics and Optometry Department, Universidad Europea de Madrid
| | - José F. Alfonso
- Fernández-Vega Ophthalmological Institute
- Surgery Department, School of Medicine, University of Oviedo
| | | | | |
Collapse
|
41
|
Hütz WW, Bahner K, Röhrig B, Hengerer F. The Combination of Diffractive and Refractive Multifocal Intraocular Lenses to Provide Full Visual Function after Cataract Surgery. Eur J Ophthalmol 2018; 20:370-5. [DOI: 10.1177/112067211002000217] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
42
|
Alfonso JF, Fernández-Vega L, Ortí S, Ferrer-Blasco T, Montés-Micó R. Refractive and Visual Results after Implantation of the AcrySof ReSTOR IOL in High and Low Hyperopic Eyes. Eur J Ophthalmol 2018; 19:748-53. [DOI: 10.1177/112067210901900511] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- José F. Alfonso
- Fernández-Vega Ophthalmological Institute, Oviedo
- Surgery Department, School of Medicine, University of Oviedo
| | - Luis Fernández-Vega
- Fernández-Vega Ophthalmological Institute, Oviedo
- Surgery Department, School of Medicine, University of Oviedo
| | - Susana Ortí
- Optics Department, Faculty of Physics, University of Valencia - Spain
| | | | | |
Collapse
|
43
|
Alfonso JF, Fernández-Vega L, Ortí S, Ferrer-Blasco T, Montés-Micó R. Differences in Visual Performance of Acrysof ReSTOR IOL in High and Low Myopic Eyes. Eur J Ophthalmol 2018; 20:333-9. [DOI: 10.1177/112067211002000212] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- José F. Alfonso
- Fernández-Vega Ophthalmological Institute, Oviedo
- Surgery Department, School of Medicine, University of Oviedo, Oviedo
| | - Luis Fernández-Vega
- Fernández-Vega Ophthalmological Institute, Oviedo
- Surgery Department, School of Medicine, University of Oviedo, Oviedo
| | - Susana Ortí
- Optics Department, Faculty of Physics, University of Valencia, Valencia - Spain
| | | | - Robert Montés-Micó
- Optics Department, Faculty of Physics, University of Valencia, Valencia - Spain
| |
Collapse
|
44
|
Visual Acuity, Contrast Sensitivity, Subjective Quality of Vision, and Quality of Life with 4 Different Multifocal IOLs. Eur J Ophthalmol 2018; 22:175-87. [DOI: 10.5301/ejo.2011.8371] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/19/2011] [Indexed: 11/20/2022]
|
45
|
Cuq C, Spera C, Laurendeau C, Lafuma A, Berdeaux G. Intermediate Visual Acuity without Spectacles following Bilateral ReSTOR® Implantation. Eur J Ophthalmol 2018; 18:733-8. [DOI: 10.1177/112067210801800512] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose This survey determined uncorrected visual acuity (VA) at near, intermediate, and far distances in cataract patients implanted with ReSTOR®, and assessed patient satisfaction. Methods Consecutive cataract patients implanted bilaterally with ReSTOR® were followed up at least 4 months. The Early Treatment Diabetic Retinopathy Study scale was used to measure VA for near (40 cm), intermediate (50, 60, and 70 cm), and distance vision, with VAs expressed in logMAR and adjusted for distance using Bennett's (1993) formula. Satisfaction was self-rated on a visual analogue scale ranging from 0 (poor) to 10 (high). Results Twenty-four consecutive patients (mean age 67.6 years) were operated upon by a single surgeon and followed up for a mean of 336.5 days after second eye surgery. Average postoperative VAs for uncorrected distance were 0.06 logMAR and intermediate VAs were 0.21 logMAR at both 50 cm and 60 cm and 0.22 logMAR at 70 cm. These levels of uncorrected intermediate VA would allow patients to read Word® computer text in Times New Roman font 8 zoomed to 100%, at 70 cm from the monitor screen. The authors found that 23/24 patients (96%) no longer wore spectacles. The remaining patient required correction for astigmatism as this refraction error is not yet correctable by ReSTOR®. Average self-rated satisfaction was 8.54. Conclusions In an everyday surgical practice, none of the studied bilateral ReSTOR® cataract patients without astigmatism required spectacles when followed up 6 months or later. Intermediate VA was compatible with reading and led to high patient satisfaction.
Collapse
Affiliation(s)
- C. Cuq
- Nouvelle Clinique de L'Union, L'Union
| | - C. Spera
- Alcon Laboratories, Rueil-Malmaison
| | | | | | | |
Collapse
|
46
|
Renieri G, Kurz S, Schneider A, Eisenmann D. ReSTOR® Diffractive versus Array®2 Zonal-progressive Multifocal Intraocular Lens: a Contralateral Comparison. Eur J Ophthalmol 2018; 17:720-8. [DOI: 10.1177/112067210701700506] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- G. Renieri
- Department of Ophthalmology
- Department of Ophthalmology, St. Moritz and Kreuzspital Chur, Chur - Switzerland
| | | | - A. Schneider
- Department of Medical Biometry, Epidemiology and Informatics, Johannes Gutenberg University, Mainz - Germany
| | - D. Eisenmann
- Department of Ophthalmology, St. Moritz and Kreuzspital Chur, Chur - Switzerland
| |
Collapse
|
47
|
Ling J, Qian Y, Lu P. Secondary multifocal intraocular lens implantation: A novel management strategy for white cataracts. SAGE Open Med Case Rep 2018; 6:2050313X17750336. [PMID: 29326824 PMCID: PMC5758960 DOI: 10.1177/2050313x17750336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Accepted: 11/29/2017] [Indexed: 11/15/2022] Open
Abstract
Objectives: This study was designed to analyse the outcomes of secondary multifocal intraocular lens implantation in eyes with white cataracts. Methods: White cataract patients undergoing secondary multifocal intraocular lens implantation between June 2014 and January 2015 were evaluated prospectively. As opposed to a conventional primary intraocular lens implantation for an optimal patient, the white cataract was first extracted, followed by optical biometry measurements. Whether or not the patient had adequate visual acuity was identified, and the multifocal intraocular lens was implanted secondarily. A total of five appropriate white cataract patients were enrolled in this secondary multifocal intraocular lens implantation study and were retrospectively reviewed. Results: All five secondary implantations of the multifocal intraocular lenses were successful, without obvious adverse events. The uncorrected near visual acuity LogMAR was 0.4–0.5, and the distance visual acuity was −0.1 to 0.1 after 12 months of the multifocal intraocular lens implantation. All patients achieved satisfactory near and distance visual acuities and spectacle freedom. Conclusion: Two-stage multifocal intraocular lens implantation is a safe and novel technique for the management of white cataract patients to optimise near and distance visual acuities.
Collapse
Affiliation(s)
- Jiawen Ling
- Department of Ophthalmology, The Third People’s Hospital of Zhangjiagang, Zhangjiagang, China
- Department of Ophthalmology, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Yiyong Qian
- Department of Ophthalmology, The First Affiliated Hospital of Soochow University, Suzhou, China
| | - Peirong Lu
- Department of Ophthalmology, The First Affiliated Hospital of Soochow University, Suzhou, China
- Peirong Lu, Department of Ophthalmology, The First Affiliated Hospital of Soochow University, 188 Shizi Street, Suzhou 215006, Jiangsu, China.
| |
Collapse
|
48
|
Cho MH, Park JY, Park BG, Lee JS. Clinical Efficacy of Bunny Multifocal Intraocular Lens after Cataract Surgery. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2018. [DOI: 10.3341/jkos.2018.59.12.1129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Myung Ho Cho
- Department of Ophthalmology, Pusan National University College of Medicine, Busan, Korea
| | - Jae Yeong Park
- Department of Ophthalmology, Pusan National University College of Medicine, Busan, Korea
| | - Byung Gun Park
- Department of Opthalmology, Inje University Busan Paik Hospital, Busan, Korea
| | - Jong Soo Lee
- Department of Ophthalmology, Pusan National University College of Medicine, Busan, Korea
| |
Collapse
|
49
|
Abstract
Purpose: The purpose of this study is to detect the changes in pupil size developing after phacoemulsification surgery. Methods: Seventy-five eyes of a total of 49 patients (32 males and 17 females) were included in this prospective clinical trial. Routine preoperative ophthalmological examinations of the patients were performed. The presence of any systemic diseases, the presence or history of ocular trauma, uveitis, optic neuropathy or anisocoria, using ocular or systemic medications, and also the presence of any other serious ocular diseases except cataract was considered as criteria for exclusion. The age range of patients included in the study is 48–81 years. Patients who developed surgical complications were excluded from the study. Pupil measurements were made after each patient waited in a dark room for 5 min preoperatively and were repeated 1 month after the operation. The Oasis brand of pupillometer was used for pupil measurement. Results: The mean, standard deviation, median, minimum-maximum, ratio, and frequency were used for the descriptive statistics of the data. Postoperative pupil size was seen to significantly decrease compared to the preoperative period (P < 0.05). The mean value of preoperative pupil size decreased from 4.9 ± 1.0 to 4.1 ± 0.9 mm 1 month after operation. Conclusion: The pupil size is important in phacoemulsification especially combination with phacoemulsification and multifocal intraocular lens implantation. It should be considered that better postoperative visual outcomes would be obtained by accompanying postoperative pupil size reduction into preoperative measurements. Thus, we recommend MIOLs that function independent of pupil size as appropriate for cataract surgeries in elderly patients.
Collapse
Affiliation(s)
- Ibrahim Sahbaz
- Department of Opticianry, Uskudar University, Istanbul, Turkey
| |
Collapse
|
50
|
Kohnen T, Herzog M, Hemkeppler E, Schönbrunn S, De Lorenzo N, Petermann K, Böhm M. Visual Performance of a Quadrifocal (Trifocal) Intraocular Lens Following Removal of the Crystalline Lens. Am J Ophthalmol 2017; 184:52-62. [PMID: 28923587 DOI: 10.1016/j.ajo.2017.09.016] [Citation(s) in RCA: 92] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Revised: 09/08/2017] [Accepted: 09/09/2017] [Indexed: 11/29/2022]
Abstract
PURPOSE To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). METHODS Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. STUDY POPULATION Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. MAIN OUTCOME MEASURE(S) At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. RESULTS Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). CONCLUSION Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively.
Collapse
Affiliation(s)
- Thomas Kohnen
- Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany.
| | - Michael Herzog
- Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
| | - Eva Hemkeppler
- Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
| | - Sabrina Schönbrunn
- Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
| | - Nina De Lorenzo
- Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
| | - Kerstin Petermann
- Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
| | - Myriam Böhm
- Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
| |
Collapse
|