1
|
Zangalli CS, Jammal AA, Reis ASC, Ayub G, Diniz-Filho A, Paranhos A, Paula JS, Costa VP. Minimum Rim Width and Peripapillary Retinal Nerve Fiber Layer Thickness for Diagnosing Early to Moderate Glaucoma. J Glaucoma 2023; 32:526-532. [PMID: 36730041 DOI: 10.1097/ijg.0000000000002156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Accepted: 11/16/2022] [Indexed: 02/03/2023]
Abstract
PRCIS In a cross-sectional study from a Brazilian multiracial population, minimum rim width (MRW) and peripapillary retinal nerve fiber layer thickness measurements from OCT showed comparable diagnostic performance in discriminating early to moderate glaucoma from healthy eyes. PURPOSE The purpose of this study is to compare the ability of MRW and peripapillary retinal nerve fiber layer thickness (RNFLT) measurements in discriminating early to moderate glaucoma from healthy eyes in a Brazilian population. METHODS A total of 155 healthy controls and 118 patients with mild to moderate glaucoma (mean deviation >-12 dB) underwent MRW and RNFLT measurements with optical coherence tomography. Only 1 eye per patient was included in the analysis. A receiver operating characteristic (ROC) regression model was used to evaluate the diagnostic accuracy of MRW and RNFLT, whereas adjusting for age and Bruch membrane opening area. Sensitivities at fixed specificities of 95% were calculated for each parameter. RESULTS Global RNFLT and MRW showed comparable area under the ROC curves [0.93 (0.91-0.96) and 0.93 (0.89-0.96), respectively; P =0.973]. Both parameters had similar sensitivities (75% vs. 74%, respectively; P =0.852) at a fixed specificity of 95%. The best sector for diagnosing glaucoma for both parameters was the temporal inferior sector, which showed an area under the ROC curve of 0.93 (0.87-0.96) for RNFLT and 0.91 (0.86-0.95) for MRW ( P =0.320). The temporal inferior sector showed similar sensitivities for RNFLT and MRW measurements (83% vs. 77%, respectively) at a fixed specificity of 95% (P =0.230). CONCLUSIONS MRW and RNFLT measurements showed comparable diagnostic performance in discriminating early to moderate glaucoma from healthy eyes in a Brazilian multiracial population.
Collapse
|
2
|
Circular functional analysis of OCT data for precise identification of structural phenotypes in the eye. Sci Rep 2021; 11:23336. [PMID: 34857787 PMCID: PMC8639843 DOI: 10.1038/s41598-021-02025-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 10/18/2021] [Indexed: 11/09/2022] Open
Abstract
Progressive optic neuropathies such as glaucoma are major causes of blindness globally. Multiple sources of subjectivity and analytical challenges are often encountered by clinicians in the process of early diagnosis and clinical management of these diseases. In glaucoma, the structural damage is often characterized by neuroretinal rim (NRR) thinning of the optic nerve head, and other clinical parameters. Baseline structural heterogeneity in the eyes can play a key role in the progression of optic neuropathies, and present challenges to clinical decision-making. We generated a dataset of Optical Coherence Tomography (OCT) based high-resolution circular measurements on NRR phenotypes, along with other clinical covariates, of 3973 healthy eyes as part of an established clinical cohort of Asian Indian participants. We introduced CIFU, a new computational pipeline for CIrcular FUnctional data modeling and analysis. We demonstrated CIFU by unsupervised circular functional clustering of the OCT NRR data, followed by meta-clustering to characterize the clusters using clinical covariates, and presented a circular visualization of the results. Upon stratification by age, we identified a healthy NRR phenotype cluster in the age group 40-49 years with predictive potential for glaucoma. Our dataset also addresses the disparity of representation of this particular population in normative OCT databases.
Collapse
|
3
|
Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in a Brazilian population of healthy subjects. PLoS One 2018; 13:e0206887. [PMID: 30562371 PMCID: PMC6298691 DOI: 10.1371/journal.pone.0206887] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2018] [Accepted: 10/23/2018] [Indexed: 11/30/2022] Open
Abstract
Objective To determine Bruch’s membrane opening (BMO) minimum rim width (MRW) and peripapillary retinal nerve fiber layer thickness (RNFLT) measurements, acquired with optical coherence tomography (OCT) in healthy Brazilian individuals self-reported as African Descent (AD), European Descent (ED) and Mixed Descent (MD). Methods 260 healthy individuals (78 AD, 103 ED and 79 MD) were included in this cross-sectional study conducted at the Clinics Hospital of the University of Campinas. We obtained optic nerve head (24 radial B scans) and peripapillary retinal nerve fiber layer (3.5-mm circle scan) images in one randomly selected eye of each subject. Results After adjustment for BMO area and age, there were no significant differences in mean global MRW (P = 0.63) or RNFLT (P = 0.07) among the three groups. Regionally, there were no significant differences in either MRW or RNFLT in most sectors, except in the superonasal sector, in which both MRW and RNFLT were thinner among ED (P = 0.04, P<0.001, respectively). RNFLT was also thinner in ED in the inferonasal sector (P = 0.009). In all races, global MRW decreased and global RNFLT increased with BMO area. AD subjects had higher rates of global RNFLT decay with age (-0.32 μm/year) compared to ED and MD subjects (-0.10 μm/year and -0.08 μm/year, respectively; P = 0.01 and P = 0.02, respectively). Conclusions and relevance While we found no significant differences in global MRW and RNFLT among the three races, age-related thinning of the RNFLT was significantly higher in the AD subgroup, which warrants further study.
Collapse
|
4
|
Torres LA, Vianna JR, Jarrar F, Sharpe GP, Araie M, Caprioli J, Demirel S, Girkin CA, Hangai M, Iwase A, Liebmann JM, Mardin CY, Nakazawa T, Quigley HA, Scheuerle AF, Sugiyama K, Tanihara H, Tomita G, Yanagi Y, Burgoyne CF, Chauhan BC. Protruded retinal layers within the optic nerve head neuroretinal rim. Acta Ophthalmol 2018; 96:e493-e502. [PMID: 30105788 DOI: 10.1111/aos.13657] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2017] [Accepted: 11/06/2017] [Indexed: 01/06/2023]
Abstract
PURPOSE To determine the frequency with which retinal tissues other than the nerve fibre layer, hereafter referred to as protruded retinal layers (PRL), are a component of optical coherence tomography (OCT) neuroretinal rim measurements. METHODS Ninety healthy (30 White, Black and Japanese, respectively) subjects were included in the study. A radial scan pattern (24 B-scans centred on Bruch's membrane opening [BMO]) was used. For each of the 48 minimum rim width (MRW) measurement points, we determined whether PRL were present, absent or indeterminate. When present, the proportion of PRL within the MRW was quantified. RESULTS Protruded retinal layers were present in 503 (11.6%), absent in 3805 (88.1%) and indeterminate in 12 (0.3%) measurement points. Overall, 69 (76.6%) subjects had ≥1 points with PRL, with White subjects having the highest frequency and Japanese the lowest (29 [97%] and 18 [60%], respectively; p < 0.01). PRL were present in one-third of points in the temporal sector, but ≤5% in other sectors. When present, the median PRL thickness was 53.0 (interquartile range [IQR]: 33.0 to 78.5) μm, representing 20.6 (IQR: 13.0 to 28.5)% of MRW. Globally, the median PRL thickness comprised 1.3 (IQR: 0.2 to 3.5)% of the MRW; however, in the temporal sector, it exceeded 30% of MRW in some subjects. CONCLUSIONS Protruded retinal layers are a component of MRW measurements in most normal subjects, occurring in almost 12% of all measurement points analysed. There were racial variations in the presence of PRL and a significantly higher frequency of PRL in the temporal sector.
Collapse
Affiliation(s)
- Lucas A. Torres
- Department of Ophthalmology and Visual Sciences; Dalhousie University; Halifax Nova Scotia Canada
| | - Jayme R. Vianna
- Department of Ophthalmology and Visual Sciences; Dalhousie University; Halifax Nova Scotia Canada
| | - Faisal Jarrar
- Department of Ophthalmology and Visual Sciences; Dalhousie University; Halifax Nova Scotia Canada
| | - Glen P. Sharpe
- Department of Ophthalmology and Visual Sciences; Dalhousie University; Halifax Nova Scotia Canada
| | - Makoto Araie
- Kanto Central Hospital of the Mutual Aid Association of Public School Teachers; Tokyo Japan
| | - Joseph Caprioli
- Department of Ophthalmology; Jules Stein Eye Institute; University of California Los Angeles; Los Angeles California USA
| | - Shaban Demirel
- Devers Eye Institute; Legacy Research Institute; Portland Oregon USA
| | - Christopher A. Girkin
- Department of Ophthalmology; University of Alabama at Birmingham; Birmingham Alabama USA
| | - Masanori Hangai
- Department of Ophthalmology; Saitama Medical School; Moro Japan
| | | | - Jeffrey M. Liebmann
- New York Eye and Ear Infirmary; New York University School of Medicine; New York New York USA
| | | | - Toru Nakazawa
- Department of Ophthalmology; Tohoku University Graduate School of Medicine; Tohoku Japan
| | - Harry A. Quigley
- Wilmer Ophthalmological Institute; Johns Hopkins University; Baltimore Maryland USA
| | | | - Kazuhisa Sugiyama
- Department of Ophthalmology and Visual Science; Kanazawa University Graduate School of Medical Science; Kanazawa Japan
| | - Hidenobu Tanihara
- Department of Ophthalmology; Faculty of Life Sciences; Kumamoto University; Kumamoto Japan
| | - Goji Tomita
- Department of Ophthalmology; Toho University Ohashi Medical Center; Tokyo Japan
| | - Yasuo Yanagi
- Department of Ophthalmology; The University of Tokyo Graduate School of Medicine; Tokyo Japan
| | | | - Balwantray C. Chauhan
- Department of Ophthalmology and Visual Sciences; Dalhousie University; Halifax Nova Scotia Canada
| |
Collapse
|
5
|
Filek R, Hooper P, Sheidow T, Gonder J, Varma DK, Heckler L, Hodge W, Chakrabarti S, Hutnik CML. Structural and functional changes to the retina and optic nerve following panretinal photocoagulation over a 2-year time period. Eye (Lond) 2017; 31:1237-1244. [PMID: 28452993 DOI: 10.1038/eye.2017.66] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2016] [Accepted: 03/15/2017] [Indexed: 01/07/2023] Open
Abstract
PurposeTo evaluate long-term structural and functional changes to the retina and optic nerve following panretinal photocoagulation (PRP) in diabetic retinopathy (DR) patients.MethodsParticipants were patients with DR requiring PRP and control patients with DR not requiring PRP. The Heidelberg retinal tomography (HRT) and optical coherence tomography (OCT) were performed to analyze the optic nerve and macula. Best-corrected visual acuity (BCVA) and visual field (VF) testing were done to measure central and peripheral vision. Wide-field fluorescein angiogram was performed to monitor the progression of diabetic ischemia. The primary outcome measure was to determine the degree of retinal and optic nerve changes before and after PRP.ResultsThere was a non-significant thickening of the macula and retinal nerve fiber layer at 6 months post laser that recovered by 24 months. Mean perfused ratio was significantly increased (P=0.02) at 12 and 24 months post laser. Independently grading patient stereophotographs, grader 1 indicated there was a non-significant increase in cup to disk ratio post laser, while grader 2 indicated a significant increase at 6 (P=0.04), 12 (P=0.02), and 24 months (P=0.005). There was a significant VF decrease (P≤0.02) at 12 and 24 months post laser with BCVA showing a non-significant trend of deteriorating results.ConclusionDespite an improvement in peripheral perfusion, there was a significant progressive decline of peripheral VF over the study period. Clinical grading of the optic nerve was more unreliable following PRP, despite the absence of significant morphological changes as detected by the OCT and HRT.
Collapse
Affiliation(s)
- R Filek
- Department of Pathology and Laboratory Medicine, Western University, London, Ontario, Canada
| | - P Hooper
- Department of Ophthalmology, Western University, London, Ontario, Canada.,Department of Ophthalmology, Western University, Ivey Eye Institute, St Joseph's Hospital, London, Ontario, Canada
| | - T Sheidow
- Department of Ophthalmology, Western University, London, Ontario, Canada.,Department of Ophthalmology, Western University, Ivey Eye Institute, St Joseph's Hospital, London, Ontario, Canada
| | - J Gonder
- Department of Ophthalmology, Western University, London, Ontario, Canada.,Department of Ophthalmology, Western University, Ivey Eye Institute, St Joseph's Hospital, London, Ontario, Canada
| | - D K Varma
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada
| | - L Heckler
- Département d'ophtalmologie, Université de Montréal, Montreal, Québec, Canada
| | - W Hodge
- Department of Ophthalmology, Western University, London, Ontario, Canada.,Department of Ophthalmology, Western University, Ivey Eye Institute, St Joseph's Hospital, London, Ontario, Canada.,Department of Epidemiology and Biostatistics, Western University, London, Ontario, Canada
| | - S Chakrabarti
- Department of Pathology and Laboratory Medicine, Western University, London, Ontario, Canada
| | - C M L Hutnik
- Department of Pathology and Laboratory Medicine, Western University, London, Ontario, Canada.,Department of Ophthalmology, Western University, London, Ontario, Canada.,Department of Ophthalmology, Western University, Ivey Eye Institute, St Joseph's Hospital, London, Ontario, Canada
| |
Collapse
|
6
|
Begum VU, Addepalli UK, Senthil S, Garudadri CS, Rao HL. Optic nerve head parameters of high-definition optical coherence tomography and Heidelberg retina tomogram in perimetric and preperimetric glaucoma. Indian J Ophthalmol 2016; 64:277-84. [PMID: 27221679 PMCID: PMC4901845 DOI: 10.4103/0301-4738.182938] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Background: Heidelberg retina tomogram (HRT) and optical coherence tomography (OCT) are two widely used imaging modalities to evaluate the optic nerve head (ONH) in glaucoma. Purpose: To compare the ONH parameters of HRT3 and high-definition OCT (HD-OCT) and evaluate their diagnostic abilities in perimetric and preperimetric glaucoma. Design: Cross-sectional analysis. Methods: 35 control eyes (24 subjects), 21 preperimetric glaucoma eyes (15 patients), and 64 perimetric glaucoma eyes (44 patients) from the Longitudinal Glaucoma Evaluation Study underwent HRT3 and HD-OCT examinations. Statistical Analysis: Agreement between the ONH parameters of HRT and HD-OCT were assessed using Bland-Altman plots. Diagnostic abilities of ONH parameters were evaluated using area under the receiver operating characteristic curves (AUCs), sensitivity at fixed specificity, and likelihood ratios (LR). Results: Optic disc area, vertical cup to disc ratio, and cup volume with HD-OCT were larger than with HRT, while the rim area was smaller with HD-OCT (P < 0.001 for all comparisons). AUCs of all HD-OCT ONH parameters (0.90-0.97 in perimetric and 0.62-0.71 in preperimetric glaucoma) were comparable (P > 0.10) to the corresponding HRT ONH parameters (0.81-0.95 in perimetric and 0.55-0.72 in preperimetric glaucoma). LRs associated with diagnostic categorization of ONH parameters of both HD-OCT and HRT were associated with larger effects on posttest probability of perimetric compared to preperimetric glaucoma. Conclusions: ONH measurements of HD-OCT and HRT3 cannot be used interchangeably. Though the diagnostic abilities of ONH parameters of HD-OCT and HRT in glaucoma were comparable, the same were significantly lower in preperimetric compared to perimetric glaucoma.
Collapse
Affiliation(s)
- Viquar Unnisa Begum
- VST Glaucoma Center, L. V. Prasad Eye Institute, Hyderabad, Telangana, India
| | | | - Sirisha Senthil
- VST Glaucoma Center, L. V. Prasad Eye Institute, Hyderabad, Telangana, India
| | | | - Harsha Laxmana Rao
- VST Glaucoma Center, L. V. Prasad Eye Institute, Hyderabad, Telangana, India
| |
Collapse
|
7
|
Silverman AL, Hammel N, Khachatryan N, Sharpsten L, Medeiros FA, Girkin CA, Liebmann JM, Weinreb RN, Zangwill LM. Diagnostic Accuracy of the Spectralis and Cirrus Reference Databases in Differentiating between Healthy and Early Glaucoma Eyes. Ophthalmology 2016; 123:408-414. [PMID: 26526632 PMCID: PMC4724549 DOI: 10.1016/j.ophtha.2015.09.047] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2015] [Revised: 09/28/2015] [Accepted: 09/30/2015] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To evaluate and compare the diagnostic accuracy of global and sector analyses for detection of early visual field (VF) damage using the retinal nerve fiber layer (RNFL) reference databases of the Spectralis (Heidelberg Engineering, Heidelberg, Germany) and Cirrus (Carl Zeiss Meditec, Dublin, CA) spectral-domain optical coherence tomography (SD OCT) devices. METHODS Healthy subjects and glaucoma suspects from the Diagnostic Innovations in Glaucoma Study (DIGS) and African Descent and Glaucoma Evaluation Study (ADAGES) with at least 2 years of follow-up were included. Global and sectoral RNFL measures were classified as within normal limits, borderline (BL), and outside normal limits (ONL) on the basis of the device reference databases. The sensitivity of ONL classification was estimated in glaucoma suspect eyes that developed repeatable VF damage. RESULTS A total of 353 glaucoma suspect eyes and 279 healthy eyes were included. A total of 34 (9.6%) of the glaucoma suspect eyes developed VF damage. In glaucoma suspect eyes, Spectralis and Cirrus ONL classification was present in 47 eyes (13.3%) and 24 eyes (6.8%), respectively. The sensitivity of the global RNFL ONL classification among eyes that developed VF damage was 23.5% for Cirrus and 32.4% for Spectralis. The specificity of within-normal-limits global classification in healthy eyes was 100% for Cirrus and 99.6% for Spectralis. There was moderate to substantial agreement between Cirrus and Spectralis classification as ONL. CONCLUSIONS The Spectralis and Cirrus reference databases have a high specificity for identifying healthy eyes and good agreement for detection of eyes with early glaucoma damage.
Collapse
Affiliation(s)
- Anna L Silverman
- Department of Ophthalmology, Hamilton Glaucoma Center, University of California San Diego, La Jolla, California; George Washington University School of Medicine and Health Sciences, Washington, District of Columbia
| | - Naama Hammel
- Department of Ophthalmology, Hamilton Glaucoma Center, University of California San Diego, La Jolla, California
| | - Naira Khachatryan
- Department of Ophthalmology, Hamilton Glaucoma Center, University of California San Diego, La Jolla, California
| | - Lucie Sharpsten
- Department of Ophthalmology, Hamilton Glaucoma Center, University of California San Diego, La Jolla, California
| | - Felipe A Medeiros
- Department of Ophthalmology, Hamilton Glaucoma Center, University of California San Diego, La Jolla, California
| | | | - Jeffrey M Liebmann
- Harkness Eye Institute, Columbia University Medical Center, New York, New York
| | - Robert N Weinreb
- Department of Ophthalmology, Hamilton Glaucoma Center, University of California San Diego, La Jolla, California
| | - Linda M Zangwill
- Department of Ophthalmology, Hamilton Glaucoma Center, University of California San Diego, La Jolla, California.
| |
Collapse
|
8
|
Abstract
PURPOSE To describe the process by which imaging devices undergo reference database development and regulatory clearance. The limitations and potential improvements of reference (normative) data sets for ophthalmic imaging devices will be discussed. METHOD A symposium was held in July 2013 in which a series of speakers discussed issues related to the development of reference databases for imaging devices. RESULTS Automated imaging has become widely accepted and used in glaucoma management. The ability of such instruments to discriminate healthy from glaucomatous optic nerves, and to detect glaucomatous progression over time is limited by the quality of reference databases associated with the available commercial devices. In the absence of standardized rules governing the development of reference databases, each manufacturer's database differs in size, eligibility criteria, and ethnic make-up, among other key features. CONCLUSIONS The process for development of imaging reference databases may be improved by standardizing eligibility requirements and data collection protocols. Such standardization may also improve the degree to which results may be compared between commercial instruments.
Collapse
|
9
|
Michelessi M, Lucenteforte E, Oddone F, Brazzelli M, Parravano M, Franchi S, Ng SM, Virgili G. Optic nerve head and fibre layer imaging for diagnosing glaucoma. Cochrane Database Syst Rev 2015; 2015:CD008803. [PMID: 26618332 PMCID: PMC4732281 DOI: 10.1002/14651858.cd008803.pub2] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
BACKGROUND The diagnosis of glaucoma is traditionally based on the finding of optic nerve head (ONH) damage assessed subjectively by ophthalmoscopy or photography or by corresponding damage to the visual field assessed by automated perimetry, or both. Diagnostic assessments are usually required when ophthalmologists or primary eye care professionals find elevated intraocular pressure (IOP) or a suspect appearance of the ONH. Imaging tests such as confocal scanning laser ophthalmoscopy (HRT), optical coherence tomography (OCT) and scanning laser polarimetry (SLP, as used by the GDx instrument), provide an objective measure of the structural changes of retinal nerve fibre layer (RNFL) thickness and ONH parameters occurring in glaucoma. OBJECTIVES To determine the diagnostic accuracy of HRT, OCT and GDx for diagnosing manifest glaucoma by detecting ONH and RNFL damage. SEARCH METHODS We searched several databases for this review. The most recent searches were on 19 February 2015. SELECTION CRITERIA We included prospective and retrospective cohort studies and case-control studies that evaluated the accuracy of OCT, HRT or the GDx for diagnosing glaucoma. We excluded population-based screening studies, since we planned to consider studies on self-referred people or participants in whom a risk factor for glaucoma had already been identified in primary care, such as elevated IOP or a family history of glaucoma. We only considered recent commercial versions of the tests: spectral domain OCT, HRT III and GDx VCC or ECC. DATA COLLECTION AND ANALYSIS We adopted standard Cochrane methods. We fitted a hierarchical summary ROC (HSROC) model using the METADAS macro in SAS software. After studies were selected, we decided to use 2 x 2 data at 0.95 specificity or closer in meta-analyses, since this was the most commonly-reported level. MAIN RESULTS We included 106 studies in this review, which analysed 16,260 eyes (8353 cases, 7907 controls) in total. Forty studies (5574 participants) assessed GDx, 18 studies (3550 participants) HRT, and 63 (9390 participants) OCT, with 12 of these studies comparing two or three tests. Regarding study quality, a case-control design in 103 studies raised concerns as it can overestimate accuracy and reduce the applicability of the results to daily practice. Twenty-four studies were sponsored by the manufacturer, and in 15 the potential conflict of interest was unclear.Comparisons made within each test were more reliable than those between tests, as they were mostly based on direct comparisons within each study.The Nerve Fibre Indicator yielded the highest accuracy (estimate, 95% confidence interval (CI)) among GDx parameters (sensitivity: 0.67, 0.55 to 0.77; specificity: 0.94, 0.92 to 0.95). For HRT measures, the Vertical Cup/Disc (C/D) ratio (sensitivity: 0.72, 0.60 to 0.68; specificity: 0.94, 0.92 to 0.95) was no different from other parameters. With OCT, the accuracy of average RNFL retinal thickness was similar to the inferior sector (0.72, 0.65 to 0.77; specificity: 0.93, 0.92 to 0.95) and, in different studies, to the vertical C/D ratio.Comparing the parameters with the highest diagnostic odds ratio (DOR) for each device in a single HSROC model, the performance of GDx, HRT and OCT was remarkably similar. At a sensitivity of 0.70 and a high specificity close to 0.95 as in most of these studies, in 1000 people referred by primary eye care, of whom 200 have manifest glaucoma, such as in those who have already undergone some functional or anatomic testing by optometrists, the best measures of GDx, HRT and OCT would miss about 60 cases out of the 200 patients with glaucoma, and would incorrectly refer 50 out of 800 patients without glaucoma. If prevalence were 5%, e.g. such as in people referred only because of family history of glaucoma, the corresponding figures would be 15 patients missed out of 50 with manifest glaucoma, avoiding referral of about 890 out of 950 non-glaucomatous people.Heterogeneity investigations found that sensitivity estimate was higher for studies with more severe glaucoma, expressed as worse average mean deviation (MD): 0.79 (0.74 to 0.83) for MD < -6 db versus 0.64 (0.60 to 0.69) for MD ≥ -6 db, at a similar summary specificity (0.93, 95% CI 0.92 to 0.94 and, respectively, 0.94; 95% CI 0.93 to 0.95; P < 0.0001 for the difference in relative DOR). AUTHORS' CONCLUSIONS The accuracy of imaging tests for detecting manifest glaucoma was variable across studies, but overall similar for different devices. Accuracy may have been overestimated due to the case-control design, which is a serious limitation of the current evidence base.We recommend that further diagnostic accuracy studies are carried out on patients selected consecutively at a defined step of the clinical pathway, providing a description of risk factors leading to referral and bearing in mind the consequences of false positives and false negatives in the setting in which the diagnostic question is made. Future research should report accuracy for each threshold of these continuous measures, or publish raw data.
Collapse
Affiliation(s)
- Manuele Michelessi
- Ophthalmology, Fondazione G.B. Bietti per lo studio e la ricerca in Oftalmolologia-IRCCS, Via Livenza n 3, Rome, Italy, 00198
| | | | | | | | | | | | | | | |
Collapse
|
10
|
Lee NY, Park HYL, Park CK. Glaucoma Detection in High Myopia with the Heidelberg Retina Tomograph 3. Semin Ophthalmol 2015; 30:377-82. [DOI: 10.3109/08820538.2014.902481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
11
|
Chauhan BC, Danthurebandara VM, Sharpe GP, Demirel S, Girkin CA, Mardin CY, Scheuerle AF, Burgoyne CF. Bruch's Membrane Opening Minimum Rim Width and Retinal Nerve Fiber Layer Thickness in a Normal White Population: A Multicenter Study. Ophthalmology 2015. [PMID: 26198806 DOI: 10.1016/j.ophtha.2015.06.001] [Citation(s) in RCA: 117] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE Conventional optic disc margin-based neuroretinal rim measurements lack a solid anatomic and geometrical basis. An optical coherence tomography (OCT) index, Bruch's membrane opening minimum rim width (BMO-MRW), addresses these deficiencies and has higher diagnostic accuracy for glaucoma. We characterized BMO-MRW and peripapillary retinal nerve fiber layer thickness (RNFLT) in a normal population. DESIGN Multicenter cross-sectional study. PARTICIPANTS Normal white subjects. METHODS An approximately equal number of subjects in each decade group (20-90 years of age) was enrolled in 5 centers. Subjects had normal ocular and visual field examination results. We obtained OCT images of the optic nerve head (24 radial scans) and peripapillary retina (1 circular scan). The angle between the fovea and BMO center (FoBMO angle), relative to the horizontal axis of the image frame, was first determined and all scans were acquired and analyzed relative to this eye-specific FoBMO axis. Variation in BMO-MRW and RNFLT was analyzed with respect to age, sector, and BMO shape. MAIN OUTCOME MEASURES Age-related decline and between-subject variability in BMO-MRW and RNFLT. RESULTS There were 246 eyes of 246 subjects with a median age of 52.9 years (range, 19.8-87.3 years). The median FoBMO angle was -6.7° (range, 2.5° to -17.5°). The BMO was predominantly vertically oval with a median area of 1.74 mm(2) (range, 1.05-3.40 mm(2)). Neither FoBMO angle nor BMO area was associated with age or axial length. Both global mean BMO-MRW and RNFLT declined with age at a rate of -1.34 μm/year and -0.21 μm/year, equivalent to 4.0% and 2.1% loss per decade of life, respectively. Sectorially, the most rapid decrease occurred inferiorly and the least temporally; however, the age association was always stronger with BMO-MRW than with RNFLT. There was a modest relationship between mean global BMO-MRW and RNFLT (r = 0.35), whereas sectorially the relationship ranged from moderate (r = 0.45, inferotemporal) to nonexistent (r = 0.01, temporal). CONCLUSIONS There was significant age-related loss of BMO-MRW in healthy subjects and notable differences between BMO-MRW and RNFLT in their relationship with age and between each other. Adjusting BMO-MRW and RNFLT for age and sector is important in ensuring optimal diagnostics for glaucoma.
Collapse
Affiliation(s)
- Balwantray C Chauhan
- Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Canada.
| | | | - Glen P Sharpe
- Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Canada
| | | | | | | | | | | |
Collapse
|
12
|
Maslin JS, Mansouri K, Dorairaj SK. HRT for the Diagnosis and Detection of Glaucoma Progression. Open Ophthalmol J 2015; 9:58-67. [PMID: 26069518 PMCID: PMC4460217 DOI: 10.2174/1874364101509010058] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2015] [Revised: 03/30/2015] [Accepted: 03/30/2015] [Indexed: 11/22/2022] Open
Abstract
Confocal scanning laser ophthalmoscopy through the Heidelberg Retina Tomograph (HRT) provides a rapid, safe, noncontact, and noninvasive imaging of the optic disc in three-dimensions, and provides precise detailed information about the optic disc beyond that which the clinical exam can measure. The HRT I was developed for research purposes only and was not used clinically. The HRT II was developed to be user-friendly, more rapid, and was used as an adjunct to clinical examination in the detection and progression of glaucoma. One of the main pitfalls of the HRT II was that it was operator-dependent. The HRT III was developed to be operator-independent. Initially the Moorsfield Regression Analysis provided the analysis of the stereometric optic disc parameters. The Glaucoma Probability Score, given its ease of use, operator-independence, and rapidity of use, soon gained popularity. Numerous studies have compared these two methods of analysis, with the conclusion that the Glaucoma Probability Score provides a higher sensitivity and a lower specificity than the Moorsfield Regression Analysis, which may indicate that it has potential as a screening test for glaucoma. However, there is no consensus on the use of the Glaucoma Probability Score as a screening test for glaucoma. While HRT data may be useful as a clinical adjunct in the screening and diagnosis of glaucoma, it should ultimately only be used to support clinical examination.
Collapse
Affiliation(s)
- Jessica S Maslin
- Ophthalmology and Visual Science, Yale University School of Medicine, New Haven, CT, USA
| | - Kaweh Mansouri
- Division of Ophthalmology, Department of Clinical Neurosciences, Geneva University Hospitals, Geneva, Switzerland
| | | |
Collapse
|
13
|
Abstract
PURPOSE OF REVIEW The use of ophthalmic imaging for documentation and diagnosis of ocular disease is rising dramatically. Optical coherence tomography (OCT), confocal scanning laser tomography (CSLT), scanning laser polarimetry (SLP) and photographic imaging of the optic nerve head (ONH) are currently used to document baseline characteristics of the ONH and for diagnosing glaucoma and glaucoma progression secondary to loss of retinal nerve fiber layer (RNFL). Imaging modalities typically provide information on ONH and RNFL characteristics which are outside of the normal (relative to normative databases) in red lettering or boxes, whereas ONH and RNFL characteristics within the normal range are presented in green. RECENT FINDINGS As imaging modalities have become more sophisticated and are validated in research studies, clinicians have come to rely upon data from these imaging devices to aid in differentiating between normal and glaucomatous states of the ONH and RNFL - typically by examining if the data are green or red suggesting normal or abnormal. However, normative databases can sometimes be flawed relative to atypical ONH or RNFL morphologies and imaging can provide artifacts which do not represent true ocular disease but secondary to limitations of imaging technology. SUMMARY Ophthalmic imaging is an important adjunct to clinical diagnosis but the results from imaging devices need to be assessed critically relative to artifacts of imaging and the limitations of the technology and its normative databases.
Collapse
|
14
|
Linear Discriminant Functions to Improve the Glaucoma Probability Score Analysis to Detect Glaucomatous Optic Nerve Heads. J Glaucoma 2013; 22:73-9. [DOI: 10.1097/ijg.0b013e31823298b3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
15
|
Lisboa R, Leite MT, Zangwill LM, Tafreshi A, Weinreb RN, Medeiros FA. Diagnosing preperimetric glaucoma with spectral domain optical coherence tomography. Ophthalmology 2012; 119:2261-9. [PMID: 22883689 DOI: 10.1016/j.ophtha.2012.06.009] [Citation(s) in RCA: 91] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2012] [Revised: 04/11/2012] [Accepted: 06/04/2012] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To evaluate the diagnostic accuracy of spectral domain optical coherence tomography (SD-OCT) for detection of preperimetric glaucoma and compare it with the performance of confocal scanning laser ophthalmoscopy (CSLO). DESIGN Cohort study. PARTICIPANTS A cohort of 134 eyes of 88 glaucoma suspects based on the appearance of the optic disc. METHODS Patients were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS). All eyes underwent retinal nerve fiber layer (RNFL) imaging with Spectralis SD-OCT (Heidelberg Engineering, Carlsbad, CA) and topographic imaging with Heidelberg Retinal Tomograph III (HRT-III) (Heidelberg Engineering) CSLO within 6 months of each other. All patients had normal visual fields at the time of imaging and were classified on the basis of history of documented stereophotographic evidence of progressive glaucomatous change in the appearance of the optic nerve occurring before the imaging sessions. MAIN OUTCOME MEASURES Areas under the receiver operating characteristic curves (AUCs) were calculated to summarize diagnostic accuracies of the SD-OCT and CSLO. Likelihood ratios (LRs) were reported using the diagnostic categorization provided by each instrument after comparison to its normative database. RESULTS Forty-eight eyes of 42 patients had evidence of progressive glaucomatous change and were included in the preperimetric glaucoma group. Eighty-six eyes of 46 patients without any evidence of progressive glaucomatous change followed untreated for an average of 14.0 ± 3.6 years were included in the control group. The parameter with the largest AUC obtained with the SD-OCT was the temporal superior RNFL thickness (0.88 ± 0.03), followed by global RNFL thickness (0.86 ± 0.03) and temporal inferior RNFL thickness (0.81 ± 0.04). The parameter with the largest AUC obtained with the CSLO was rim area (0.72 ± 0.05), followed by rim volume (0.71 ± 0.05) and linear cup-to-disk ratio (0.66 ± 0.05). Temporal superior RNFL average thickness measured by SD-OCT performed significantly better than rim area measurements from CSLO (0.88 vs. 0.72; P=0.008). Outside normal limits results for SD-OCT parameters were associated with strongly positive LRs. CONCLUSIONS The RNFL assessment with SD-OCT performed well in detecting preperimetric glaucomatous damage in a cohort of glaucoma suspects and had a better performance than CSLO.
Collapse
Affiliation(s)
- Renato Lisboa
- Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California, USA
| | | | | | | | | | | |
Collapse
|
16
|
Knight OJ, Girkin CA, Budenz DL, Durbin MK, Feuer WJ. Effect of race, age, and axial length on optic nerve head parameters and retinal nerve fiber layer thickness measured by Cirrus HD-OCT. ACTA ACUST UNITED AC 2012; 130:312-8. [PMID: 22411660 DOI: 10.1001/archopthalmol.2011.1576] [Citation(s) in RCA: 191] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
OBJECTIVE To determine the effect of race, demographic, and ocular variables on optic nerve head and retinal nerve fiber layer (RNFL) thickness measurements using spectral-domain optical coherence tomography. METHODS In a cross-sectional observational study, 284 normal subjects aged 18 to 84 years were evaluated at 7 sites using Cirrus HD-OCT. Disc area, rim area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and average, temporal, superior, nasal, and inferior RNFL thicknesses were calculated. The main outcome measures were associations between Cirrus HD-OCT optic nerve head and RNFL measurements and age, sex, and race. RESULTS The 284 subjects self-identified as being of European (122), Chinese (63), African (51), or Hispanic (35) descent. After adjusting for the effect of age, there was a statistically significant difference among racial groups for all optic nerve head and RNFL parameters (all P ≤ .005) except rim area (P = .22). Rim area, average cup-disc ratio, vertical cup-disc ratio, and cup volume were moderately associated with disc area (r(2) = 0.15, 0.33, 0.33, and 0.37, respectively). After a linear adjustment for disc area, there was no statistically significant difference among racial groups for any optic nerve head parameter. Individuals of European descent had thinner RNFL measurements except in the temporal quadrant. CONCLUSIONS There are racial differences in optic disc area, average cup-disc ratio, vertical cup-disc ratio, cup volume, and RNFL thickness as measured by Cirrus HD-OCT. These differences should be considered when using Cirrus HD-OCT to assess for glaucomatous damage in differing population groups.
Collapse
Affiliation(s)
- O'Rese J Knight
- Bascom Palmer Eye Institute, Miller School of Medicine, University of Miami, Miami, Florida, USA
| | | | | | | | | | | |
Collapse
|
17
|
Reis ASC, O'Leary N, Yang H, Sharpe GP, Nicolela MT, Burgoyne CF, Chauhan BC. Influence of clinically invisible, but optical coherence tomography detected, optic disc margin anatomy on neuroretinal rim evaluation. Invest Ophthalmol Vis Sci 2012; 53:1852-60. [PMID: 22410561 DOI: 10.1167/iovs.11-9309] [Citation(s) in RCA: 184] [Impact Index Per Article: 14.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
PURPOSE We previously demonstrated that most eyes have regionally variable extensions of Bruch's membrane (BM) inside the clinically identified disc margin (DM) that are clinically and photographically invisible. We studied the impact of these findings on DM- and BM opening (BMO)-derived neuroretinal rim parameters. METHODS Disc stereo-photography and spectral domain optical coherence tomography (SD-OCT, 24 radial B-scans centered on the optic nerve head) were performed on 30 glaucoma patients and 10 age-matched controls. Photographs were colocalized to SD-OCT data such that the DM and BMO could be visualized in each B-scan. Three parameters were computed: (1) DM-horizontal rim width (HRW), the distance between the DM and internal limiting membrane (ILM) along the DM reference plane; (2) BMO-HRW, the distance between BMO and ILM along the BMO reference plane; and (3) BMO-minimum rim width (MRW), the minimum distance between BMO and ILM. Rank-order correlations of sectors ranked by rim width and spatial concordance measured as angular distances between equivalently ranked sectors were derived. RESULTS The average DM position was external to BMO in all quadrants, except inferotemporally. There were significant sectoral differences among all three rim parameters. DM-HRW and BMO-HRW sector ranks were better correlated (median ρ = 0.84) than DM-HRW and BMO-MRW (median ρ = 0.55), or BMO-HRW and BMO-MRW (median ρ = 0.60) ranks. Sectors with the narrowest BMO-MRW were infrequently the same as those with the narrowest DM-HRW or BMO-HRW. CONCLUSIONS BMO-MRW quantifies the neuroretinal rim from a true anatomical outer border and accounts for its variable trajectory at the point of measurement.
Collapse
Affiliation(s)
- Alexandre S C Reis
- Department of Ophthalmology and Visual Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | | | | | | | | | | | | |
Collapse
|
18
|
Abstract
Evidence-based medicine is an evolving new paradigm. With the advent of numerous new diagnostic techniques and therapeutic interventions, one needs to critically evaluate and validate them by appropriate methods before adopting them into day-to-day patient care. The concepts involved in the evaluation of diagnostic tests and therapy are discussed. For delivering the highest level of clinical care, evidence alone is not sufficient. Integrating individual clinical experience and patients' perspectives with the best available external evidence is essential.
Collapse
Affiliation(s)
- Chandrasekhar Garudadri
- VST Center for Glaucoma, LV Prasad Eye Institute, Kallam Anji Reddy Campus, LV Prasad Marg, Road No 2, Banjara Hills, Hyderabad 500 034, Andhra Pradesh, India.
| | | | | |
Collapse
|
19
|
Current World Literature. Curr Opin Ophthalmol 2011; 22:141-6. [DOI: 10.1097/icu.0b013e32834483fc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|