1
|
Trinh M, Kalloniatis M, Khuu SK, Nivison-Smith L. Retinal sensitivity changes in early/intermediate AMD: a systematic review and meta-analysis of visual field testing under mesopic and scotopic lighting. Eye (Lond) 2024:10.1038/s41433-024-03033-0. [PMID: 38499857 DOI: 10.1038/s41433-024-03033-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 01/22/2024] [Accepted: 03/08/2024] [Indexed: 03/20/2024] Open
Abstract
Visual fields under mesopic and scotopic lighting are increasingly being used for macular functional assessment. This review evaluates its statistical significance and clinical relevance, and the optimal testing protocol for early/intermediate age-related macular degeneration (AMD). PubMed and Embase were searched from inception to 14/05/2022. All quality assessments were performed according to GRADE guidelines. The primary outcome was global mean sensitivity (MS), further meta-analysed by: AMD classification scheme, device, test pattern, mesopic/scotopic lighting, stimuli size/chromaticity, pupil dilation, testing radius (area), background luminance, adaptation time, AMD severity, reticular pseudodrusen presence, and follow-up visit. From 1489 studies screened, 42 observational study results contributed to the primary meta-analysis. Supported by moderate GRADE certainty of the evidence, global MS was significantly reduced across all devices under mesopic and scotopic lighting with large effect size (-0.9 [-1.04, -0.75] Hedge's g, P < 0.0001). The device (P < 0.01) and lighting (P < 0.05) used were the only modifiable factors affecting global MS, whereby the mesopic MP-1 and MAIA produced the largest effect sizes and exceeded test-retest variabilities. Global MS was significantly affected by AMD severity (intermediate versus early AMD; -0.58 [-0.88, -0.29] Hedge's g or -2.55 [3.62, -1.47] MAIA-dB) and at follow-up visit (versus baseline; -0.62 [-0.84, -0.41] Hedge's g or -1.61[-2.69, -0.54] MAIA-dB). Magnitudes of retinal sensitivity changes in early/intermediate AMD are clinically relevant for the MP-1 and MAIA devices under mesopic lighting within the central 10° radius. Other factors including pupil dilation and dark adaptation did not significantly affect global MS in early/intermediate AMD.
Collapse
Affiliation(s)
- Matt Trinh
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Michael Kalloniatis
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
- School of Medicine (Optometry), Deakin University, Geelong, VIC, Australia
| | - Sieu K Khuu
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Lisa Nivison-Smith
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia.
| |
Collapse
|
2
|
Jeffrey BG, Flynn OJ, Huryn LA, Pfau M, Cukras CA. Scotopic Contour Deformation Detection Reveals Early Rod Dysfunction in Age-Related Macular Degeneration With and Without Reticular Pseudodrusen. Invest Ophthalmol Vis Sci 2022; 63:23. [PMID: 35749129 PMCID: PMC9234356 DOI: 10.1167/iovs.63.6.23] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose The purpose of this study was to investigate scotopic contour deformation detection (sCDD), and its structural determinants, in participants with intermediate age-related macular degeneration (iAMD) with or without reticular pseudodrusen (RPD). Methods Forty-one participants (aged 58–89 years), including 9 with iAMD and RPD, 16 with iAMD only, and 16 controls, underwent functional testing. The sCDD was evaluated with radial frequency arcs presented at 4 loci: ±4 degrees and 8 degrees vertical eccentricity. Scotopic thresholds and dark adaptation (DA) were measured at the same loci. Retinal layers of spectral domain optical coherence tomography (SD-OCT) volume scans were segmented. To establish the concurrent validity of the functional test, we evaluated the fraction of variability in sCDD thresholds explained by SD-OCT data. Results The iAMD group had significantly worse sCDD thresholds compared with controls (8 degrees inferior retina: P = 0.004 and the 4 degrees loci: P < 0.02 for both). Elevated sCDD thresholds were observed in iAMD and RPD eyes at loci with normal scotopic thresholds; the opposite was rarely encountered. Elevated sCDD thresholds were also observed in iAMD eyes with normal DA. Elevated sCDD thresholds were associated with increased age and presence of late AMD in the fellow eye. The optimal machine learning model predicted 16% of variability (cross-validated R2) in sCDD thresholds at 8 degrees. Discussion A novel scotopic contour deformation task can provide unique information about rod dysfunction in participants with iAMD and RPD not observed with structural and other functional assessments. Rod dysfunction observed with scotopic contour deformation testing was associated with factors linked to risk of AMD progression.
Collapse
Affiliation(s)
- Brett G Jeffrey
- National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
| | - Oliver J Flynn
- National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
| | - Laryssa A Huryn
- National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
| | - Maximilian Pfau
- National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States.,University of Bonn, Bonn, Germany
| | - Catherine A Cukras
- National Eye Institute, National Institutes of Health, Bethesda, Maryland, United States
| |
Collapse
|
3
|
von der Emde L, Pfau M, Holz FG, Fleckenstein M, Kortuem K, Keane PA, Rubin DL, Schmitz-Valckenberg S. AI-based structure-function correlation in age-related macular degeneration. Eye (Lond) 2021; 35:2110-2118. [PMID: 33767409 PMCID: PMC8302753 DOI: 10.1038/s41433-021-01503-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2020] [Revised: 02/24/2021] [Accepted: 03/09/2021] [Indexed: 11/22/2022] Open
Abstract
Sensitive and robust outcome measures of retinal function are pivotal for clinical trials in age-related macular degeneration (AMD). A recent development is the implementation of artificial intelligence (AI) to infer results of psychophysical examinations based on findings derived from multimodal imaging. We conducted a review of the current literature referenced in PubMed and Web of Science among others with the keywords ‘artificial intelligence’ and ‘machine learning’ in combination with ‘perimetry’, ‘best-corrected visual acuity (BCVA)’, ‘retinal function’ and ‘age-related macular degeneration’. So far AI-based structure-function correlations have been applied to infer conventional visual field, fundus-controlled perimetry, and electroretinography data, as well as BCVA, and patient-reported outcome measures (PROM). In neovascular AMD, inference of BCVA (hereafter termed inferred BCVA) can estimate BCVA results with a root mean squared error of ~7–11 letters, which is comparable to the accuracy of actual visual acuity assessment. Further, AI-based structure-function correlation can successfully infer fundus-controlled perimetry (FCP) results both for mesopic as well as dark-adapted (DA) cyan and red testing (hereafter termed inferred sensitivity). Accuracy of inferred sensitivity can be augmented by adding short FCP examinations and reach mean absolute errors (MAE) of ~3–5 dB for mesopic, DA cyan and DA red testing. Inferred BCVA, and inferred retinal sensitivity, based on multimodal imaging, may be considered as a quasi-functional surrogate endpoint for future interventional clinical trials in the future.
Collapse
Affiliation(s)
| | - Maximilian Pfau
- Department of Ophthalmology, University of Bonn, Bonn, Germany.,Department of Biomedical Data Science, Radiology, and Medicine, Stanford University, Stanford, CA, USA
| | - Frank G Holz
- Department of Ophthalmology, University of Bonn, Bonn, Germany
| | | | - Karsten Kortuem
- Augenklinik, Universität Ulm, Ulm, Deutschland.,Augenarztpraxis Dres. Kortüm, Ludwigsburg, Deutschland
| | - Pearse A Keane
- Moorfields Eye Hospital NHS Foundation Trust, London, UK
| | - Daniel L Rubin
- Department of Biomedical Data Science, Radiology, and Medicine, Stanford University, Stanford, CA, USA
| | - Steffen Schmitz-Valckenberg
- Department of Ophthalmology, University of Bonn, Bonn, Germany. .,John A. Moran Eye Center, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
4
|
Ho AC, Heier JS, Holekamp NM, Garfinkel RA, Ladd B, Awh CC, Singh RP, Sanborn GE, Jacobs JH, Elman MJ, Loewenstein A, Eichenbaum DA. Real-World Performance of a Self-Operated Home Monitoring System for Early Detection of Neovascular Age-Related Macular Degeneration. J Clin Med 2021; 10:jcm10071355. [PMID: 33806058 PMCID: PMC8036735 DOI: 10.3390/jcm10071355] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/16/2021] [Accepted: 03/19/2021] [Indexed: 12/26/2022] Open
Abstract
The real-world performance of a home telemonitoring strategy (ForeseeHome AMD Monitoring System®, Notal Vision, Inc.,Manassas VA, USA) was evaluated and compared to the device arm of the AREDS2-HOME study among patients with intermediate AMD (iAMD) who converted to neovascular AMD (nAMD). All patients with confirmed conversion to nAMD who used the home monitoring system from 10/2009 through 9/2018 were identified by Notal Vision Diagnostic Clinic’s medical records. Selected outcome variables were evaluated, including visual acuity (VA) at baseline and at conversion, and change in visual acuity (VA) from baseline to time of conversion. In total, 8991 patients performed 3,200,999 tests at a frequency of 5.6 ± 3.2 times/week. The 306 eyes that converted from iAMD to nAMD over the study period (a 2.7% annual rate) were included in the analyses. There was a median (interquartile range) change of −3.0 (0.0–(−10.0)) letters among converted eyes, 81% [95% confidence interval (72–88%)] maintained a VA ≥ 20/40 at the time of conversion, while 69% of the conversion detections were triggered by system alerts. The real-world performance of an at-home testing strategy was similar to that reported for the device arm of the AREDS2-HOME study. The home telemonitoring system can markedly increase early detection of conversion to nAMD.
Collapse
Affiliation(s)
- Allen C. Ho
- Wills Eye Hospital, 840 Walnut St., Philadelphia, PA 19107, USA;
| | - Jeffrey S. Heier
- Ophthalmic Consultants of Boston, 50 Staniford St., Ste. 600, Boston, MA 02114, USA;
| | - Nancy M. Holekamp
- Pepose Vision Institute, 1815 Clarkson Road, Chesterfield, MO 63124, USA;
| | | | - Byron Ladd
- Virginia Eye Institute, 6946 Forest Ave Suite 100, Richmond, VA 23230, USA;
| | - Carl C. Awh
- Tennessee Retina, 345 23rd Avenue North, Suite 350, Nashville, TN 37203, USA;
| | - Rishi P. Singh
- Center for Ophthalmic Bioinformatics, Cole Eye Institute, Cleveland Clinic Foundation, 9500 Euclid Avenue, i-32, Cleveland, OH 44106, USA;
| | - George E. Sanborn
- Notal Vision, 7717 Coppermine Dr., Manassas, VA 20109, USA; (G.E.S.); (J.H.J.)
| | - Jennifer H. Jacobs
- Notal Vision, 7717 Coppermine Dr., Manassas, VA 20109, USA; (G.E.S.); (J.H.J.)
| | - Michael J. Elman
- Elman Retina, 7671 Quarterfield Rd #100, Glen Burnie, MD 21061, USA;
| | - Anat Loewenstein
- Department of Ophthalmology, Tel Aviv Medical Center, Tel Aviv 6209105, Israel
- The Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel
- Correspondence:
| | - David A. Eichenbaum
- Retina Vitreous Associates of Florida, 4344 Central Ave, St. Petersburg, FL 33711, USA;
| |
Collapse
|