1
|
Barça F, Demir EB, İbolar M, Atilla HA, Akdoğan M. Do all short stem types restore biomechanical parameters of the hip? Comparison according to femoral neck osteotomy levels. Int Orthop 2024:10.1007/s00264-024-06176-7. [PMID: 38589708 DOI: 10.1007/s00264-024-06176-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2024] [Accepted: 04/02/2024] [Indexed: 04/10/2024]
Abstract
PURPOSE There is no consensus on ideal short femoral stem design. A classification system proposed by Feyen and Shimmin divides short stems in two types according to femoral neck osteotomy levels: subcapital (IIIA) and standard (IIIB). The study aims to determine which design type is more successful in restoring native biomechanical parameters and whether stem type has an impact on clinical results. METHODS In this retrospective comparative study, patients that have undergone short stem hip arthroplasty were evaluated according to stem types: type IIIA (n = 52, 66.7%) (Mathys Optimys) and IIIB (n = 26, 33.3%) (Implantcast Aida and Smith & Nephew SMF). Pelvis X-rays were assessed in terms of femoral neck length, horizontal and vertical hip centres of rotation, horizontal and vertical femoral offsets, abductor lever arm lengths, leg lengths, and stem-shaft angles. Improvement in Harris hip scores, differences between post-operative and pre-operative measurements, and stem-shaft angles were evaluated and compared between two groups. RESULTS Mean femoral neck resection (8.27 ± 6.68 mm in IIIA and 15 ± 6.33 mm in IIIB) was significantly different between both groups (p < 0.001). Harris hip scores were increased at post-operative six months in both groups with no difference (84.4 ± 6.4 and 84.6 ± 5.5, p = 0.4). The absolute values of differences between pre-operative and post-operative horizontal centres of rotation (p = 0.63), vertical centers of rotation (p = 0.75), horizontal femoral offsets (p = 0.78), vertical femoral offsets (p = 0.83), abductor lever arm distances (p = 0.63), and leg length (p = 0.21) measurements were not different between both groups. Stem positions were both varus with no statistically significant difference between groups (p = 0.14). CONCLUSION We found no difference regarding restoration of biomechanical parameters between short stem designs with different levels of neck osteotomy. Additionally, short stem can mostly result in varus component positioning regardless of the level of neck osteotomy.
Collapse
Affiliation(s)
- Fatih Barça
- Ankara Etlik City Hospital, Varlık Mah. Halil Sezai Erkut Cd. Yenimahalle, 06170, Ankara, Turkey.
| | - Ekin Barış Demir
- Ankara Etlik City Hospital, Varlık Mah. Halil Sezai Erkut Cd. Yenimahalle, 06170, Ankara, Turkey
| | - Mithat İbolar
- Bitlis State Hospital, Ministry of Health of Turkey, Beşminare Mah. 160 Evler Mevkii, 13000, Bitlis, Turkey
| | - Halis Atıl Atilla
- Ankara Etlik City Hospital, Varlık Mah. Halil Sezai Erkut Cd. Yenimahalle, 06170, Ankara, Turkey
| | - Mutlu Akdoğan
- Ankara Etlik City Hospital, Varlık Mah. Halil Sezai Erkut Cd. Yenimahalle, 06170, Ankara, Turkey
| |
Collapse
|
2
|
Gounot A, Charlot A, Guillon P, Schaefer A, Moslemi A, Boutroux P, Sautet A. The use of uncemented stems in femoral neck fractures in elderly patients: A comparative study of 671 cases. Orthop Traumatol Surg Res 2024:103878. [PMID: 38582221 DOI: 10.1016/j.otsr.2024.103878] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 10/07/2023] [Accepted: 02/14/2024] [Indexed: 04/08/2024]
Abstract
INTRODUCTION The use of cemented stems in elderly patients is associated with the risk of intraoperative embolic complications. Uncemented stems eliminate this risk, but their use is controversial because of the risk of mechanical complications, with estimated subsidence between 3.6 and 30% and periprosthetic fractures between 2.1 and 11% at 6 weeks. A retrospective multicenter comparative study was conducted using a propensity score analysis to evaluate mechanical performances of uncemented stems in femoral neck fractures in elderly patients to (1) compare the risk of mechanical complications and (2) assess the use of metaphyseal-anchored stems for this indication. HYPOTHESIS There is no difference in the risk of mechanical complications, intraoperatively or postoperatively, between these stems. MATERIALS AND METHODS We conducted a multicenter retrospective comparative study including 358 uncemented and 313 cemented stems. The mean age was 84.5 years [83.9-85.1]. The inclusion criteria were patients 70 years and older and a follow-up of at least 6 weeks. The primary endpoint was a composite endpoint comprised of stem subsidence≥2mm or periprosthetic fracture (up to 3 months postoperatively). The secondary endpoints were infection, stem subsidence≥2mm, and operative time. These endpoints were analyzed using a propensity score to control confounding factors. A secondary analysis used the same endpoints to compare metaphyseal-anchored (short stems) versus Corail-like stems. RESULTS After adjusting for the propensity score, we found 11.17% mechanical complications in the uncemented group (n=40, 5.59% subsidence, and 5.59% fractures) versus 13.42% for the cemented group (n=42, 7.99% subsidence, and 5.43% fractures). There was no statistically significant difference between the 2 values (Odds Ratio [OR]=0.64 [95% Confidence Interval [CI]: 0.14-2.85] [p=0.7]). The mortality rate due to cement embolism was 1%. There was no difference in the rate of subsidence (OR=0.55 [95% CI: 0.02-12.5] [p=0.7]), periprosthetic fracture (OR=0.65 [95% CI: 0.13-3.12] [p=0.7]) or infection (OR=0.71 [95% CI: 0.32-1.55] [p=0.4]). However, the operative times were longer in the cemented group (p=0.03 for hemiarthroplasties [mean additional time 16minutes] and p=0.02 for total hip arthroplasties [mean additional time 22minutes]). No difference was observed between the metaphyseal-anchored (short stems) and Corail-like stems regarding operative time, rate of infection, and rate of stem subsidence or periprosthetic fractures. DISCUSSION This is one of the first studies to highlight cemented stem subsidence when used for femoral neck fractures in elderly patients. Using uncemented stems in this indication is still warranted, especially since they do not bring about more mechanical complications in the first few months. Metaphyseal-anchored short stems seem to give the same results as "standard" stems. However, these findings need to be assessed in the longer term. LEVEL OF EVIDENCE III; retrospective comparative study.
Collapse
Affiliation(s)
- Alexandre Gounot
- Département de chirurgie orthopédique et traumatologique, GHI Le Raincy Montfermeil, 10, rue du Général-Leclerc, 93370 Montfermeil, France.
| | - Anahita Charlot
- Département de chirurgie orthopédique et traumatologique, GHI Le Raincy Montfermeil, 10, rue du Général-Leclerc, 93370 Montfermeil, France
| | - Pascal Guillon
- Département de chirurgie orthopédique et traumatologique, GHI Le Raincy Montfermeil, 10, rue du Général-Leclerc, 93370 Montfermeil, France
| | - Augustin Schaefer
- Département d'anesthésie, hôpital Ambroise-Paré, Assistance publique-Hôpitaux de Paris (AP-HP), 9, avenue Charles-de-Gaulle, 92100 Boulogne-Billancourt, France
| | - Aymane Moslemi
- Département de chirurgie orthopédique et traumatologique, hôpital Saint-Antoine, Assistance publique-Hôpitaux de Paris (AP-HP), 184, rue du Faubourg-Saint-Antoine, 75012 Paris, France
| | - Pierre Boutroux
- Département de chirurgie orthopédique et traumatologique, hôpital Saint-Antoine, Assistance publique-Hôpitaux de Paris (AP-HP), 184, rue du Faubourg-Saint-Antoine, 75012 Paris, France
| | - Alain Sautet
- Département de chirurgie orthopédique et traumatologique, hôpital Saint-Antoine, Assistance publique-Hôpitaux de Paris (AP-HP), 184, rue du Faubourg-Saint-Antoine, 75012 Paris, France
| |
Collapse
|
3
|
Weenders SGM, Merfort R, Eschweiler J, Hildebrand F, Gruner A, Heller KD. Ten-year follow-up and clinical outcome of a metaphyseal anchoring short hip stem prosthesis: a retrospective single-centre analysis. Int Orthop 2024; 48:419-426. [PMID: 37672119 DOI: 10.1007/s00264-023-05958-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2023] [Accepted: 08/24/2023] [Indexed: 09/07/2023]
Abstract
PURPOSE Short stems for total hip arthroplasty are an alternative to traditional conventional long stems. Short stems are designed to facilitate minimal-invasive surgery, improve bone-stock preservation, and mimic a physiological load distribution. However, there is little evidence of the long-term outcome of short stems. This study aims to analyze the ten year survival rates and clinical outcome of one specific metaphyseal short hip stem implant. METHODS We retrospectively analyzed the patient records of the patients who underwent a total hip arthroplasty with a monoblock partial collum sparing metaphyseal short hip stem prosthesis in 2008 and 2009 in our clinic. Patients were contacted, and clinical follow-up was recorded using the German version of the modified Harris Hip Score. Furthermore, complications, revision surgery, and post-operative radiographs were analyzed. RESULTS Data from 339 primary implantations in 322 patients were retrieved. The mean follow-up was 10.6 years. Seven patients underwent a revision. The ten year survival rate with any revision surgery as the endpoint was 97.5%. The mean modified Harris Hip Score was 86 points (range 30 to 91 points). Five patients had an intraoperative fracture of the femur (1.6%). Two patients (0.6%) had a dislocation of the hip. The stem tip-to-cortex distance, measured in the anterior posterior view, was 2.6 mm (range 0 to 8.3 mm). CONCLUSION The ten year survival rate of our used monoblock partial collum sparing metaphyseal short hip stem implant is comparable to traditional stems for total hip arthroplasty.
Collapse
Affiliation(s)
- S G M Weenders
- Clinic for Orthopaedic Surgery, Herzogin Elisabeth Hospital, Leipzigerstraße 24, 38124, Braunschweig, Germany.
| | - R Merfort
- Department of Orthopaedics, Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - J Eschweiler
- Department of Orthopaedics, Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - F Hildebrand
- Department of Orthopaedics, Trauma and Reconstructive Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - A Gruner
- Clinic for Orthopaedic Surgery, Herzogin Elisabeth Hospital, Leipzigerstraße 24, 38124, Braunschweig, Germany
| | - K D Heller
- Clinic for Orthopaedic Surgery, Herzogin Elisabeth Hospital, Leipzigerstraße 24, 38124, Braunschweig, Germany
| |
Collapse
|
4
|
Girard J. What role for short stems in 2023? Orthop Traumatol Surg Res 2024; 110:103779. [PMID: 38040113 DOI: 10.1016/j.otsr.2023.103779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Accepted: 03/23/2023] [Indexed: 12/03/2023]
Abstract
Current trends in total hip replacement aim at soft tissue and bone stock conservation. At the same time, mean patient age has been decreasing from decade to decade, raising the issue of iterative revision. Short stems seek to resolve the problem on the femoral side. Hopefully, revision of a short stem will be easier and bone stock depletion will be less than with a standard stem. Short stems also seem to have other advantages: automatically personalized biomechanical reconstruction, easier minimally invasive strategies, very low rate of hip pain, more harmonious distribution of bone stress, etc. Despite these advantages, however, use of short stems since their introduction in the late 1980s has varied from country to country, and is not widespread in France. The present study addressed several questions concerning these implants. Firstly, what is a "short" stem? Then, what are the indications and contraindications? Shortened standard stems do not come under the concept of short stem and will not be dealt with here. Furthermore, the learning curve and specificities of short stems need to be acquired. Implantation technique differs greatly from standard stems, and short stem implantation requires particular rigor. Results also need to be assessed, and especially the rate of complications as compared to standard stems. And lastly, it needs to be determined whether the advantages are real or only theoretical: this will determine their usefulness and role in the armamentarium, in which short stems are a new paradigm. LEVEL OF EVIDENCE: Expert opinion.
Collapse
Affiliation(s)
- Julien Girard
- Université Lille Nord de France, 59000 Lille, France; Service d'Orthopédie II, Hôpital Salengro, CHU de Lille, place de Verdun, 59000 Lille, France; Université Lille, Université Artois, Université Littoral Côte d'Opale, EA 7369, Unité de Recherche Pluridisciplinaire Sport Santé Société (URePSS), 59000 Lille, France.
| |
Collapse
|
5
|
Van Veghel MHW, Hannink G, Van Oldenrijk J, Van Steenbergen LN, Schreurs BW. A comparison of uncemented short versus standard stem length in total hip arthroplasty: results from the Dutch Arthroplasty Register. Acta Orthop 2023; 94:330-335. [PMID: 37417696 DOI: 10.2340/17453674.2023.13652] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Indexed: 07/08/2023] Open
Abstract
BACKGROUND AND PURPOSE We aimed to compare revision rates between uncemented short and standard stems in total hip arthroplasties (THAs) and the corresponding patient-reported outcome measures (PROMs). PATIENTS AND METHODS We included all short (C.F.P., Fitmore, GTS, Metha, Nanos, Optimys, Pulchra, and Taperloc Microplasty) and standard stems in uncemented THAs registered between 2009 and 2021 in the Dutch Arthroplasty Register. Kaplan-Meier survival and multivariable Cox regression analyses were performed with overall and femoral stem revision as endpoints. RESULTS Short stems were used in 3,352 and standard stems in 228,917 hips. 10-year overall revision rates (4.8%, 95% confidence interval [CI] 3.7-6.3 vs. 4.5%, CI 4.4-4.6) and femoral stem revision rates (3.0%, CI 2.2-4.2 vs. 2.3%, CI 2.2-2.4) were comparable for short- and standard-stem THAs. Today's predominant short stems (Fitmore and Optimys) showed short-term revision rates similar to that of standard-stem THAs. Other, less frequently used short stems had higher 10-year overall (6.3%, CI 4.7-8.5) and femoral stem (4.5%, CI 3.1-6.3) revision rates. Multivariable Cox regression also showed a higher risk for overall (HR 1.7, CI 1.0-2.9) and femoral stem revision (HR 2.0, CI 1.1-3.5) using the latter short stems compared with standard stems. An exploratory analysis of PROMs showed no difference. CONCLUSION There was no overall difference in revision rates but a tendency toward increased revision of short stems both for the whole THA and for the stem itself. The less frequently used short stems had increased revision risk. No difference in PROMs was shown.
Collapse
Affiliation(s)
| | - Gerjon Hannink
- Department of Medical Imaging, Radboud University Medical Center, Nijmegen
| | - Jakob Van Oldenrijk
- Erasmus University Medical Center, Department of Orthopedics and Sport Medicine, Rotterdam
| | - Liza N Van Steenbergen
- Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Interventies), 's-Hertogenbosch, the Netherlands
| | - B Willem Schreurs
- Department of Orthopedics, Radboud University Medical Center, Nijmegen; Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Interventies), 's-Hertogenbosch, the Netherlands
| |
Collapse
|
6
|
Gabrion M, Rattier S, Blondin E, Michaud A, Mertl P, Gabrion A. Survival and radioclinical evaluation of the Optimys™ short stem at more than 6years' mean follow-up: A retrospective study of 108 cases. Orthop Traumatol Surg Res 2023; 109:103470. [PMID: 36336294 DOI: 10.1016/j.otsr.2022.103470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 08/08/2022] [Accepted: 08/24/2022] [Indexed: 11/06/2022]
Abstract
INTRODUCTION The short stems developed in recent years offer an interesting alternative to standard long stems. The Optimys™ short stem has been widely studied, but not according to the National Institute for Health and Care Excellence (NICE) criteria. We therefore conducted a retrospective study of Optimys™ at a minimum 5years' follow-up, to assess: (1) survival on NICE criteria, (2) complications, (3) functional results, and (4) subsidence, restoration of offset and bone remodeling. HYPOTHESIS Optimys™ shows survival comparable to that of other non-cemented standard and short stems, with a<0.5% per year revision rate or<2.5% at 5years on NICE criteria. MATERIAL AND METHODS A single-center retrospective study included 108 Optimys™ stems at a mean 76.5months' follow-up (range: 60-112months). Clinical [Harris, Oxford-12 and forgotten hip (French version: SHO-12) scores] and radiologic data were collected pre- and postoperatively. Analysis focused on implant survival, complications, functional results and radiological results (restoration of offset, bone remodeling, subsidence and osseointegration) and risk factors for stem migration. RESULTS At a mean 76.5months' follow-up (range: 60-112months), Optimys™ survival was 97.7% (95% CI: 0.945-1). Oxford and Harris scores improved significantly: respectively, 16.1 vs. 44.7 [Δ=28.598; 95% CI: 27.410-29.785 (p<0.001)] and 45.3 vs. 95 [Δ=49.662; 95% CI: 47.442-51.882 (p<0.001)]. Mean forgotten hip score (SHO-12) at last follow-up was 82.7±19.6 (range: 35.4-100.0). There was 1 case of aseptic revision at 11months for femoral osseointegration defect. Mean subsidence was 1.64mm (range: 0-20.63mm); no predisposing factors could be identified. Femoral offset increased by a mean 2.41±4.53mm (range: -10.10 to 14.70mm). CONCLUSION The present study reports good survival for the Optimys™ stem, which meets NICE criteria. Radiologic and clinical results were encouraging, with a low rate of subsidence, comparable to other series, but with increased femoral offset. LEVEL OF EVIDENCE IV; retrospective cohort study.
Collapse
Affiliation(s)
- Matthieu Gabrion
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80054 Amiens, France.
| | - Simon Rattier
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80054 Amiens, France
| | - Emile Blondin
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80054 Amiens, France
| | - Audrey Michaud
- Direction de la recherche clinique et de l'innovation, site Sud - Hall 1 - 1(er) étage zone administrative, 1, rond-point du Professeur-Christian-Cabrol, 80054 Amiens, France
| | - Patrice Mertl
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80054 Amiens, France; UFR de médecine, pôle santé, 3, rue des Louvels, CS 13036, 80036 Amiens, France
| | - Antoine Gabrion
- Service de chirurgie orthopédique et traumatologie, CHU Amiens-Picardie, 1, rue du Professeur-Christian-Cabrol, 80054 Amiens, France; UFR de médecine, pôle santé, 3, rue des Louvels, CS 13036, 80036 Amiens, France
| |
Collapse
|