1
|
Wang X, Ye Y, Zuo H, Li Y. Neurobiological effects and mechanisms of magnetic fields: a review from 2000 to 2023. BMC Public Health 2024; 24:3094. [PMID: 39516768 PMCID: PMC11545338 DOI: 10.1186/s12889-024-18987-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Accepted: 05/29/2024] [Indexed: 11/16/2024] Open
Abstract
Magnetic fields are widely used in medical diagnostics because of their superior non-invasive properties. In addition, with the widespread use of magnetic fields in transportation and other areas, their potential hazards to human health and the assessment of their safety have attracted considerable attention. The effects of magnetic fields on living organisms have a long history. The biological effects of magnetic field exposure in mice and rats depend on the magnetic field strength, exposure time, and direction; depending on these and potentially other factors, magnetic fields can cause a series of neurobiological effects. We reviewed global research on the neurobiological effects of magnetic fields from recent years to provide an overview and insights into the underlying mechanisms. This review focuses on the biological effects of static and dynamic magnetic fields of different frequencies and intensities on animals and nerve cells and their mechanisms of action.
Collapse
Affiliation(s)
- Xuejia Wang
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, China
- College of Life Science, Hebei University, Baoding, Hebei, 071002, China
| | - Yumeng Ye
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, China
| | - Hongyan Zuo
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, China.
- College of Life Science, Hebei University, Baoding, Hebei, 071002, China.
| | - Yang Li
- Department of Experimental Pathology, Beijing Institute of Radiation Medicine, Beijing, China.
- College of Life Science, Hebei University, Baoding, Hebei, 071002, China.
| |
Collapse
|
2
|
Bouisset N, Laakso I. Induced electric fields in MRI settings and electric vestibular stimulations: same vestibular effects? Exp Brain Res 2024; 242:2493-2507. [PMID: 39261353 DOI: 10.1007/s00221-024-06910-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 08/10/2024] [Indexed: 09/13/2024]
Abstract
In Magnetic Resonance Imaging scanner environments, the continuous Lorentz Force is a potent vestibular stimulation. It is nowadays so well known that it is now identified as Magnetic vestibular stimulation (MVS). Alongside MVS, some authors argue that through induced electric fields, electromagnetic induction could also trigger the vestibular system. Indeed, for decades, vestibular-specific electric stimulations (EVS) have been known to precisely impact all vestibular pathways. Here, we go through the literature, looking at potential time varying magnetic field induced vestibular outcomes in MRI settings and comparing them with EVS-known outcomes. To date, although theoretically induction could trigger vestibular responses the behavioral evidence remains poor. Finally, more vestibular-specific work is needed.
Collapse
Affiliation(s)
- Nicolas Bouisset
- Human Threshold Research Group, Lawson Health Research Institute, London, ON, Canada.
- Department of Medical Biophysics, Western University, London, ON, Canada.
| | - Ilkka Laakso
- Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| |
Collapse
|
3
|
Bouisset N, Nissi J, Laakso I, Reynolds RF, Legros A. Is activation of the vestibular system by electromagnetic induction a possibility in an MRI context? Bioelectromagnetics 2024; 45:171-183. [PMID: 38348647 DOI: 10.1002/bem.22497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2023] [Revised: 11/21/2023] [Accepted: 12/16/2023] [Indexed: 04/17/2024]
Abstract
In recent years, an increasing number of studies have discussed the mechanisms of vestibular activation in strong magnetic field settings such as occur in a magnetic resonance imaging scanner environment. Amid the different hypotheses, the Lorentz force explanation currently stands out as the most plausible mechanism, as evidenced by activation of the vestibulo-ocular reflex. Other hypotheses have largely been discarded. Nonetheless, both human data and computational modeling suggest that electromagnetic induction could be a valid mechanism which may coexist alongside the Lorentz force. To further investigate the induction hypothesis, we provide, herein, a first of its kind dosimetric analysis to estimate the induced electric fields at the vestibular system and compare them with what galvanic vestibular stimulation would generate. We found that electric fields strengths from induction match galvanic vestibular stimulation strengths generating vestibular responses. This review examines the evidence in support of electromagnetic induction of vestibular responses, and whether movement-induced time-varying magnetic fields should be further considered and investigated.
Collapse
Affiliation(s)
- Nicolas Bouisset
- Human Threshold Research Group, Lawson Health Research Institute, London, Ontario, Canada
- School of Kinesiology, Western University, London, Ontario, Canada
| | - Janita Nissi
- Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| | - Ilkka Laakso
- Department of Electrical Engineering and Automation, Aalto University, Espoo, Finland
| | - Raymond F Reynolds
- School of Sport, Exercise & Rehabilitation Sciences, University of Birmingham, Birmingham, UK
| | - Alexandre Legros
- Human Threshold Research Group, Lawson Health Research Institute, London, Ontario, Canada
- School of Kinesiology, Western University, London, Ontario, Canada
- EuroMov Digital Health in Motion, Univ Montpellier, IMT Mines Ales, Montpellier, France
- Departments of Medical Biophysics and Medical Imaging Western University, London, Ontario, Canada
- Eurostim, Montpellier, France
| |
Collapse
|
4
|
Emre M, Karamazi Y, Emre T, Avci Ç, Aydin C, Ebrahimi S, Pekmezekmek AB. The effect of 6GHz radiofrequency electromagnetic radiation on rat pain perception. Electromagn Biol Med 2024:1-8. [PMID: 38521997 DOI: 10.1080/15368378.2024.2331134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 03/10/2024] [Indexed: 03/25/2024]
Abstract
This paper presents data on pain perception in rats exposed to 6 GHz radiofrequency electromagnetic radiation (RF-EMR). Rats were divided into two groups: control (n = 10, 4 replicates per test) and RF-EMR exposed group (n = 10, 4 replicates per test). Nociceptive responses of the groups were measured using rodent analgesiometry. Rats were divided into control and RF-EMR exposed groups. Nociceptive responses were measured using rodent analgesiometry. RF-EMR exposed rats had a 15% delay in responding to hot plate thermal stimulation compared to unexposed rats. The delay in responding to radiant heat thermal stimulation was 21%. We determined that RF-EMR promoted the occurrence of pressure pain as statistical significance by + 42% (p < 0.001). We observed that RF-EMR exposure increased nociceptive pain by + 35% by promoting cold plate stimulation (p < 0.05). RF-EMR exposure did not affect thermal preference as statistical significance but did support the formation of pressure pain perception.
Collapse
Affiliation(s)
- Mustafa Emre
- Department of Biophysics, Faculty of Medicine, Çukurova University, Adana, Türkiye
| | - Yasin Karamazi
- Department of Biophysics, Faculty of Medicine, Çukurova University, Adana, Türkiye
| | - Toygar Emre
- Department of Industry, Faculty of Engineering, Boğaziçi University, İstanbul, Türkiye
| | - Çağrı Avci
- Department of Virology, Ceyhan Veterinary Medicine, Cukurova University, Adana, Türkiye
| | - Cagatay Aydin
- Department of Pharmacology, Faculty of Medicine, Çukurova University, Adana, Türkiye
| | - Sonia Ebrahimi
- Department of Electrical-Electronics, Faculty of Engineering, Ege University, Izmir, Türkiye
| | | |
Collapse
|
5
|
Zhao W, Han Y, Shao D, Han C, Tian Y, Huang Q. Effects of ultra-strong static magnetic field on the gut microbiota of humans and mice. Bioelectromagnetics 2023; 44:211-220. [PMID: 37655442 DOI: 10.1002/bem.22482] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Revised: 06/27/2023] [Accepted: 07/18/2023] [Indexed: 09/02/2023]
Abstract
To explore the effect of ultra-strong static magnetic field on gut microbiota, 16 T static magnetic field was used to study the changes in the structure and composition of human and mouse gut microbiota in this environment. In the mouse gut microbiota, at the genus level, the magnetic field significantly decreased the relative abundances of Escherichia-Shigella, Lactobacillus, Enterococcus, Burkholderia-Caballeronia-Paraburkholderia, Parasutterella, and Ralstonia and significantly increased those of Parabacteroides, Alloprevotella, Alistipes, Odoribacter, Bacteroides, Mucispirillum, Sutterella, and Prevotellaceae_UCG-001. Similarly, at the genus level, the relative abundances of Bacteroides, Parabacteroides, Romboutsia, and Streptococcus significantly decreased in the human gut microbiota. Contrary to the changing trend of the abundance in the mouse gut, the abundances of Bacteroides and Parabacteroides in the human gut were significantly reduced under magnetic field. The BugBase phenotypic prediction analysis showed that the relative abundances of five phenotypes, including anaerobism, mobile elements, potential pathogenicity, stress-tolerant, and biofilm formation, changed significantly in the mouse gut microbiota, while the relative abundances of two phenotypes, including Gram-positive and Gram-negative phenotypes, changed significantly in the human gut microbiota. The 16 T magnetic field could differently affect the composition, structure, and phenotypes of gut microbiota in human and mice, suggesting the importance of model selection in studying the biological effects of magnetic field.
Collapse
Affiliation(s)
- Wen Zhao
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Yijuan Han
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Dongyan Shao
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Cuicui Han
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Yixiao Tian
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| | - Qingsheng Huang
- Key Laboratory for Space Bioscience and Biotechnology, School of Life Sciences, Northwestern Polytechnical University, Xi'an, China
| |
Collapse
|
6
|
Chen T, Zhou ZY, Liu JY, Zheng LY, Wang ZW, Zhang XJ, Zeng S. Impact of partial bile duct ligation with or without repeated magnetic resonance imaging examinations in mice. Sci Rep 2022; 12:21014. [PMID: 36470922 PMCID: PMC9722823 DOI: 10.1038/s41598-022-25318-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 11/28/2022] [Indexed: 12/12/2022] Open
Abstract
Partial bile duct ligation (pBDL) is considered a well-tolerated cholestatic model. Magnetic resonance imaging (MRI) is one of the most widely used tools in noninvasive imaging. However, no systematic studies have reported the possible effects of repeated MRI assessments in the pBDL model. Sixty BALB/C mice were investigated. MRI images of each mouse were recorded once every 2 weeks for 6 weeks after pBDL or sham surgery. The reproducibility of the pBDL model and the reliability of MRI were examined by behavioral, physiological, biochemical, and pathological parameters. The mice showed no alterations on behavioral and physiological tests (P > 0.05) at 2, 4, and 6 weeks after pBDL. Repeated general anesthesia did not result in any impairment after pBDL (P > 0.05). The behavioral and biochemical parameters were not affected by repeated MRIs or repeated contrast-enhanced MRIs (P > 0.05). Pathological staining showed the homogeneous formation of collagenous fiber in the pBDL mice and did not indicate any influence of repeated contrast-enhanced MRI on the number of inflammatory cells or fibrotic formation (P > 0.05). Thus, pBDL is a reproducible model with many advantages for animal welfare and scientific research. Additionally, MRI, as a safe tool for longitudinal evaluation and is well tolerated in mice with cholestasis.
Collapse
Affiliation(s)
- Taili Chen
- grid.216417.70000 0001 0379 7164Department of Oncology, Xiangya Hospital, Central South University, Changsha, 410011 Hunan Province China
| | - Zi-Yi Zhou
- grid.452708.c0000 0004 1803 0208Department of Radiology, The Second Xiangya Hospital, Central South University, Changsha, 410011 Hunan Province China
| | - Jia-Yi Liu
- grid.452708.c0000 0004 1803 0208Department of Radiology, The Second Xiangya Hospital, Central South University, Changsha, 410011 Hunan Province China
| | - Li-Yun Zheng
- grid.497849.fMR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, 201800 China
| | - Zi-Wei Wang
- grid.216417.70000 0001 0379 7164Department of Psychiatry, The Second Xiangya Hospital, Central South University, Changsha, 410011 Hunan Province China
| | - Xiao-Jie Zhang
- grid.216417.70000 0001 0379 7164Department of Psychiatry, The Second Xiangya Hospital, Central South University, Changsha, 410011 Hunan Province China
| | - Shan Zeng
- grid.216417.70000 0001 0379 7164Department of Oncology, Xiangya Hospital, Central South University, Changsha, 410011 Hunan Province China
| |
Collapse
|
7
|
Cheng L, Yang B, Du H, Zhou T, Li Y, Wu J, Cao Z, Xu A. Moderate intensity of static magnetic fields can alter the avoidance behavior and fat storage of Caenorhabditis elegans via serotonin. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:43102-43113. [PMID: 35092591 DOI: 10.1007/s11356-022-18898-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 01/23/2022] [Indexed: 06/14/2023]
Abstract
Man-made static magnetic fields (SMFs) widely exist in human life as a physical environmental factor. However, the biological responses to moderate SMFs exposure and their underlying mechanisms are largely unknown. The present study was focused on exploring the nervous responses to moderate-intensity SMFs at 0.5 T and 1 T in Caenorhabditis elegans (C. elegans). We found that SMFs at either 0.5 T or 1 T had no statistically significant effects on the locomotor behaviors, while the 1 T magnetic field increased pharyngeal pumping. The avoidance behavior of the pathogenic Pseudomonas aeruginosa was greatly decreased in either 0.5 T or 1 T SMFs exposed nematodes, and the learning index was reducede from 0.52 ± 0.11 to 0.23 ± 0.17 and 0.16 ± 0.11, respectively. The total serotonin level was increased by 17.08% and 16.45% with the treatment of 0.5 T and 1 T SMF, compared to the control group; however, there were minimal effects of SMFs on other three neurotransmitters including choline, γ-aminobutyric acid (GABA), dopamine. RT-qPCR was used to further investigate the expression of serotonin-related genes, including rate-limiting enzymes, transcription factors and transport receptors. The expression levels of tph-1 and unc-86 genes were increased by SMF exposure, while those of ocr-2, osm-9, ser-1 and mod-1 genes were decreased. With the staining of lipid in either wild-type N2 or tph-1 mutants, we found that 0.5 T and 1 T SMFs decreased fat storage in C. elegans via serotonin pathway. Our study demonstrated that moderate-intensity SMFs induced neurobehavioral disorder and the reduction of fat storage by disturbing the secretion of serotonin in C. elegans, which provided new insights into elucidating nervous responses of C. elegans to moderate-intensity SMFs.
Collapse
Affiliation(s)
- Lei Cheng
- School of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei, Anhui, 230026, PR China
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Baolin Yang
- School of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei, Anhui, 230026, PR China
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Hua Du
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Tong Zhou
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Yang Li
- School of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei, Anhui, 230026, PR China
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Jiajie Wu
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Zhenxiao Cao
- School of Environmental Science and Optoelectronic Technology, University of Science and Technology of China, Hefei, Anhui, 230026, PR China
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - An Xu
- Anhui Province Key Laboratory of Environmental Toxicology and Pollution Control Technology, The Anhui High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China.
| |
Collapse
|
8
|
Wang S, Zheng M, Lou C, Chen S, Guo H, Gao Y, Lv H, Yuan X, Zhang X, Shang P. Evaluating the biological safety on mice at 16 T static magnetic field with 700 MHz radio-frequency electromagnetic field. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2022; 230:113125. [PMID: 34971997 DOI: 10.1016/j.ecoenv.2021.113125] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/22/2021] [Accepted: 12/23/2021] [Indexed: 06/14/2023]
Abstract
OBJECTIVES This study evaluated the associated biological effects of radio-frequency (RF) exposure at 16 T magnetic resonance imaging (MRI) on mice health. MATERIAL AND METHODS A total of 48 healthy 8-week-old male C57BL/6 mice were investigated. A 16 T high static magnetic field (HiSMF) was generated by a superconducting magnet, and a radiofrequency (RF) electromagnetic field for hydrogen resonance at 16 T (700 MHz) was transmitted via a homemade RF system. The mice were exposed inside the 16 T HiSMF with the 700 MHz RF field for 60 min, and the body weight, organ coefficients, histomorphology of major organs, and blood indices were analyzed for the basal state of the mice on day 0 and day 14. The Heat Shock Protein 70 (HSP70), cyclooxygenase 2 (COX2), and interleukin- 6 (IL-6) were used to evaluate the thermal effects on the brain. Locomotor activity, the open field test, tail suspension test, forced swimming test, and grip strength test were used to assess the behavioral characteristics of the mice. RESULTS The 16 T HiSMF with 700 MHz RF electromagnetic field exposure had no significant effects on body weight, organ coefficients, or histomorphology of major organs in the mice. On day 0, the expressions of HSP70 and COX2 in the brain were increased by 16 T HiSMF with 700 MHz RF electromagnetic field exposure. However, the expression of HSP70, COX2, and IL-6 had no significant difference compared with the sham group on day 14. Compared with the sham groups, the meancorpuscularvolume (MCV) on day 0 and the total protein (TP) on day 14 were increased significantly, whereas the other blood indices did not change significantly. The 16 T HiSMF with 700 MHz RF electromagnetic field exposure caused the mice to briefly circle tightly but had no effect on other behavioral indicators. CONCLUSIONS In summary, 16 T HiSMF with 700 MHz RF electromagnetic field exposure for 60 min did not have severe effects on mice.
Collapse
Affiliation(s)
- Shenghang Wang
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China; School of Life Sciences, Northwestern Polytechnical University, Xi'an, Shaanxi, China; Key Laboratory for Space Biosciences and Biotechnology, Northwestern Polytechnical University, Xi'an, Shaanxi, China
| | - Mengxuan Zheng
- Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Chenge Lou
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China; School of Life Sciences, Northwestern Polytechnical University, Xi'an, Shaanxi, China; Key Laboratory for Space Biosciences and Biotechnology, Northwestern Polytechnical University, Xi'an, Shaanxi, China
| | - Shuai Chen
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China; School of Life Sciences, Northwestern Polytechnical University, Xi'an, Shaanxi, China; Key Laboratory for Space Biosciences and Biotechnology, Northwestern Polytechnical University, Xi'an, Shaanxi, China
| | - Huijie Guo
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China; School of Life Sciences, Northwestern Polytechnical University, Xi'an, Shaanxi, China; Key Laboratory for Space Biosciences and Biotechnology, Northwestern Polytechnical University, Xi'an, Shaanxi, China
| | - Yang Gao
- School of Medicine, Zhejiang University, Hangzhou, China
| | - Huanhuan Lv
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China; School of Life Sciences, Northwestern Polytechnical University, Xi'an, Shaanxi, China; Key Laboratory for Space Biosciences and Biotechnology, Northwestern Polytechnical University, Xi'an, Shaanxi, China
| | - Xichen Yuan
- Key Laboratory for Space Biosciences and Biotechnology, Northwestern Polytechnical University, Xi'an, Shaanxi, China; Ministry of Education Key Laboratory of Micro/Nano Systems for Aerospace Northwestern Polytechnical University, Xi'an, Shaanxi, China
| | - Xiaotong Zhang
- College of Electrical Engineering, Zhejiang University, Hangzhou, China.
| | - Peng Shang
- Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen, China; Key Laboratory for Space Biosciences and Biotechnology, Northwestern Polytechnical University, Xi'an, Shaanxi, China.
| |
Collapse
|
9
|
Tkáč I, Benneyworth MA, Nichols-Meade T, Steuer EL, Larson SN, Metzger GJ, Uğurbil K. Long-term behavioral effects observed in mice chronically exposed to static ultra-high magnetic fields. Magn Reson Med 2021; 86:1544-1559. [PMID: 33821502 DOI: 10.1002/mrm.28799] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2020] [Revised: 02/11/2021] [Accepted: 03/19/2021] [Indexed: 12/18/2022]
Abstract
PURPOSE The primary goal of this study was to investigate whether chronic exposures to ultra-high B0 fields can induce long-term cognitive, behavioral, or biological changes in C57BL/6 mice. METHODS C57BL/6 mice were chronically exposed to 10.5-T or 16.4-T magnetic fields (3-h exposures, two exposure sessions per week, 4 or 8 weeks of exposure). In vivo single-voxel 1 H magnetic resonance spectroscopy was used to investigate possible neurochemical changes in the hippocampus. In addition, a battery of behavioral tests, including the Morris water-maze, balance-beam, rotarod, and fear-conditioning tests, were used to examine long-term changes induced by B0 exposures. RESULTS Hippocampal neurochemical profile, cognitive, and basic motor functions were not impaired by chronic magnetic field exposures. However, the balance-beam-walking test and the Morris water-maze testing revealed B0 -induced changes in motor coordination and balance. The tight-circling locomotor behavior during Morris water-maze tests was found as the most sensitive factor indexing B0 -induced changes. Long-term behavioral changes were observed days or even weeks subsequent to the last B0 exposure at 16.4 T but not at 10.5 T. Fast motion of mice in and out of the 16.4-T magnet was not sufficient to induce such changes. CONCLUSION Observed results suggest that the chronic exposure to a magnetic field as high as 16.4 T may result in long-term impairment of the vestibular system in mice. Although observation of mice may not directly translate to humans, nevertheless, they indicate that studies focused on human safety at very high magnetic fields are necessary.
Collapse
Affiliation(s)
- Ivan Tkáč
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Michael A Benneyworth
- Mouse Behavioral Core, Department of Neuroscience, University of Minnesota, Minneapolis, Minnesota, USA
| | - Tessa Nichols-Meade
- Mouse Behavioral Core, Department of Neuroscience, University of Minnesota, Minneapolis, Minnesota, USA
| | - Elizabeth L Steuer
- N Bud Grossman Center for Memory Research & Care, Department of Neurology, University of Minnesota, Minneapolis, Minnesota, USA
| | - Sarah N Larson
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Gregory J Metzger
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| | - Kâmil Uğurbil
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|
10
|
Static magnetic field induces abnormality of glucose metabolism in rats' brain and results in anxiety-like behavior. J Chem Neuroanat 2021; 113:101923. [PMID: 33549700 DOI: 10.1016/j.jchemneu.2021.101923] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 01/27/2021] [Accepted: 01/28/2021] [Indexed: 11/22/2022]
Abstract
In this study, fifty-four male Wistar rats were randomly divided into four groups according to the static magnetic field (SMF) intensity, namely, control, low-intensity, moderate-intensity, and high-intensity groups. The rats' whole body was exposed to a superconducting magnet exposure source. The exposure SMF intensity for the low-intensity, moderate-intensity, and high-intensity groups was 50 m T, 100 m T, and 200 m T, respectively, and the exposure time was 1 h/day for consecutive 15 days. After different exposure times, glucose metabolism in rats' brain was evaluated by micro-positron emission tomography (micro-PET), and the expression of hexokinase 1(HK1) and 6-phosphate fructokinase-1(PFK1) was detected by western blot. The exploration and locomotion abilities of the rats were evaluated by conducting open field test (OFT). Furthermore, pathological changes of rats' brain were observed under a microscope by using hematoxylin-eosin staining. PET results showed that moderate-intensity SMFs could cause fluctuant changes in glucose metabolism in rats' brain and the abnormalities were SMF intensity dependent. The expression of the two rate-limiting enzymes HK1 and PFK1 in glucose metabolism in brain significantly decreased after SMF exposure. The OFT showed that the total distance, surrounding distance, activity time, and climbing and standing times significantly decreased after SMF exposure. The main pathological changes in the brain were pyknosis, edema of neurons, and slight widening of the perivascular space, which occurred after 15 times of exposure. This study indicated that SMF exposure could lead to abnormal glucose metabolism in the brain and might result in anxiety-like behaviors.
Collapse
|
11
|
Tian X, Lv Y, Fan Y, Wang Z, Yu B, Song C, Lu Q, Xi C, Pi L, Zhang X. Safety evaluation of mice exposed to 7.0-33.0 T high-static magnetic fields. J Magn Reson Imaging 2020; 53:1872-1884. [PMID: 33382516 DOI: 10.1002/jmri.27496] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2020] [Revised: 12/14/2020] [Accepted: 12/16/2020] [Indexed: 01/26/2023] Open
Abstract
Magnetic resonance imaging (MRI) of 7 T and higher can provide superior image resolution and capability. Clinical tests have been performed in 9.4 T MRI, and 21.1 T small-bore-size MRI has also been tested in rodents. Although the safety issue is a prerequisite for their future medical application, there are very few relevant studies for the safety of static magnetic fields (SMFs) of ≧20 T. The aim of this study was to assess the biological effects of 7.0-33.0 T SMFs in healthy adult mice. This was a prospective study, in which 104 healthy adult C57BL/6 mice were divided into control, sham control, and 7.0-33.0 T SMF-exposed groups.The sham control group and SMF group were handled identically, except for the electric current for producing SMF. A separate control group was placed outside the magnet and their data were used as normal range. After 1 h exposure, all mice were routinely fed for another 2 months while their body weight and food/water consumption were monitored. After 2 months, their complete blood count, blood biochemistry, key organ weight, and histomorphology were examined. All data are normally distributed. Differences between the sham and SMF-exposed groups were evaluated by unpaired t test. Most indicators did not show statistically significant changes or were still within the normal ranges, with only a few exceptions. For example, mono % in Group 2 (11.1 T) is 6.03 ± 1.43% while the normal range is 6.60-9.90% (p < 0.05). The cholesterol level in 33 T group is 3.38 ± 0.36 mmol/L while the normal range is 2.48-3.29 mmol/L (p < 0.05). The high-density lipoprotein cholesterol level in 33 T group is 2.54 ± 0.29 mmol/L while the normal reference range is 1.89-2.43 mmol/L (p < 0.01). Exposure to 7.0-33.0 T for 1 h did not have detrimental effects on normal adult mice. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.
Collapse
Affiliation(s)
- Xiaofei Tian
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Institutes of Physical Science and Information Technology, Anhui University, Hefei, China
| | - Yue Lv
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
| | - Yixiang Fan
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
| | - Ze Wang
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, China
| | - Biao Yu
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
| | - Chao Song
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China
| | - Qingyou Lu
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, China.,Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, Hefei, China
| | - Chuanying Xi
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Li Pi
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
| | - Xin Zhang
- High Magnetic Field Laboratory, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China.,Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, China.,Institutes of Physical Science and Information Technology, Anhui University, Hefei, China
| |
Collapse
|
12
|
Lubner RJ, Kondamuri NS, Knoll RM, Ward BK, Littlefield PD, Rodgers D, Abdullah KG, Remenschneider AK, Kozin ED. Review of Audiovestibular Symptoms Following Exposure to Acoustic and Electromagnetic Energy Outside Conventional Human Hearing. Front Neurol 2020; 11:234. [PMID: 32411067 PMCID: PMC7199630 DOI: 10.3389/fneur.2020.00234] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Accepted: 03/11/2020] [Indexed: 12/14/2022] Open
Abstract
Objective: We aim to examine the existing literature on, and identify knowledge gaps in, the study of adverse animal and human audiovestibular effects from exposure to acoustic or electromagnetic waves that are outside of conventional human hearing. Design/Setting/Participants: A review was performed, which included searches of relevant MeSH terms using PubMed, Embase, and Scopus. Primary outcomes included documented auditory and/or vestibular signs or symptoms in animals or humans exposed to infrasound, ultrasound, radiofrequency, and magnetic resonance imaging. The references of these articles were then reviewed in order to identify primary sources and literature not captured by electronic search databases. Results: Infrasound and ultrasound acoustic waves have been described in the literature to result in audiovestibular symptomology following exposure. Technology emitting infrasound such as wind turbines and rocket engines have produced isolated reports of vestibular symptoms, including dizziness and nausea and auditory complaints, such as tinnitus following exposure. Occupational exposure to both low frequency and high frequency ultrasound has resulted in reports of wide-ranging audiovestibular symptoms, with less robust evidence of symptomology following modern-day exposure via new technology such as remote controls, automated door openers, and wireless phone chargers. Radiofrequency exposure has been linked to both auditory and vestibular dysfunction in animal models, with additional historical evidence of human audiovestibular disturbance following unquantifiable exposure. While several theories, such as the cavitation theory, have been postulated as a cause for symptomology, there is extremely limited knowledge of the pathophysiology behind the adverse effects that particular exposure frequencies, intensities, and durations have on animals and humans. This has created a knowledge gap in which much of our understanding is derived from retrospective examination of patients who develop symptoms after postulated exposures. Conclusion and Relevance: Evidence for adverse human audiovestibular symptomology following exposure to acoustic waves and electromagnetic energy outside the spectrum of human hearing is largely rooted in case series or small cohort studies. Further research on the pathogenesis of audiovestibular dysfunction following acoustic exposure to these frequencies is critical to understand reported symptoms.
Collapse
Affiliation(s)
- Rory J. Lubner
- Warren Alpert Medical School of Brown University, Providence, RI, United States
- Department of Otolaryngology, Harvard Medical School, Boston, MA, United States
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, United States
| | - Neil S. Kondamuri
- Warren Alpert Medical School of Brown University, Providence, RI, United States
- Department of Otolaryngology, Harvard Medical School, Boston, MA, United States
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, United States
| | - Renata M. Knoll
- Department of Otolaryngology, Harvard Medical School, Boston, MA, United States
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, United States
| | - Bryan K. Ward
- Department of Otolaryngology, Johns Hopkins University School of Medicine, Baltimore, MD, United States
| | | | - Derek Rodgers
- Madigan Army Medical Center, Tacoma, WA, United States
| | - Kalil G. Abdullah
- Department of Neurosurgery, UT Southwestern Medical Center, Dallas, TX, United States
| | - Aaron K. Remenschneider
- Department of Otolaryngology, Harvard Medical School, Boston, MA, United States
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, United States
- Department of Otolaryngology, University of Massachusetts Medical Center, Worcester, MA, United States
| | - Elliott D. Kozin
- Department of Otolaryngology, Harvard Medical School, Boston, MA, United States
- Department of Otolaryngology, Massachusetts Eye and Ear Infirmary, Boston, MA, United States
| |
Collapse
|
13
|
Tian X, Wang D, Feng S, Zhang L, Ji X, Wang Z, Lu Q, Xi C, Pi L, Zhang X. Effects of 3.5-23.0 T static magnetic fields on mice: A safety study. Neuroimage 2019; 199:273-280. [PMID: 31158482 DOI: 10.1016/j.neuroimage.2019.05.070] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2019] [Revised: 05/03/2019] [Accepted: 05/27/2019] [Indexed: 12/19/2022] Open
Abstract
People are exposed to various magnetic fields, including the high static/steady magnetic field (SMF) of MRI, which has been increased to 9.4 T in preclinical investigations. However, relevant safety studies about high SMF are deficient. Here we examined whether 3.5-23.0 T SMF exposure for 2 h has severe long-term effects on mice using 112 C57BL/6J mice. The food/water consumption, blood glucose levels, blood routine, blood biochemistry, as well as organ weight and HE stains were all examined. The food consumption and body weight were slightly decreased for 23.0 T-exposed mice (14.6%, P < 0.01, and 1.75-5.57%, P < 0.05, respectively), but not the other groups. While total bilirubin (TBIL), white blood cells, platelet and lymphocyte numbers were affected by some magnetic conditions, most of them were still within normal reference range. Although 13.5 T magnetic fields with the highest gradient (117.2 T/m) caused spleen weight increase, the blood count and biochemistry results were still within the control reference range. Moreover, the highest field 23.0 T with no gradient did not cause organ weight or blood biochemistry abnormality, which indicates that field gradient is a key parameter. Collectively, these data suggest 3.5-23.0 T static magnetic field exposure for 2 h do not have severe long-term effects on mice.
Collapse
Affiliation(s)
- Xiaofei Tian
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China; Institutes of Physical Science and Information Technology, Anhui University, Hefei, Anhui, 230601, PR China
| | - Dongmei Wang
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China; Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, Anhui, 230026, PR China
| | - Shuang Feng
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China; Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, Anhui, 230026, PR China
| | - Lei Zhang
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Xinmiao Ji
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Ze Wang
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China; Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, 230026, PR China
| | - Qingyou Lu
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China; Hefei National Laboratory for Physical Sciences at Microscale, University of Science and Technology of China, Hefei, 230026, PR China; Anhui Province Key Laboratory of Condensed Matter Physics at Extreme Conditions, Hefei, Anhui, 230031, PR China
| | - Chuanying Xi
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Li Pi
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China
| | - Xin Zhang
- High Magnetic Field Laboratory, Key Laboratory of High Magnetic Field and Ion Beam Physical Biology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, 230031, PR China; Institutes of Physical Science and Information Technology, Anhui University, Hefei, Anhui, 230601, PR China; Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, Anhui, 230026, PR China.
| |
Collapse
|
14
|
Ward BK, Roberts DC, Otero-Millan J, Zee DS. A decade of magnetic vestibular stimulation: from serendipity to physics to the clinic. J Neurophysiol 2019; 121:2013-2019. [PMID: 30969883 DOI: 10.1152/jn.00873.2018] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
For many years, people working near strong static magnetic fields of magnetic resonance imaging (MRI) machines have reported dizziness and sensations of vertigo. The discovery a decade ago that a sustained nystagmus can be observed in all humans with an intact labyrinth inside MRI machines led to a possible mechanism: a Lorentz force occurring in the labyrinth from the interactions of normal inner ear ionic currents and the strong static magnetic fields of the MRI machine. Inside an MRI, the Lorentz force acts to induce a constant deflection of the semicircular canal cupula of the superior and lateral semicircular canals. This inner ear stimulation creates a sensation of rotation, and a constant horizontal/torsional nystagmus that can only be observed when visual fixation is removed. Over time, the brain adapts to both the perception of rotation and the nystagmus, with the perception usually diminishing over a few minutes, and the nystagmus persisting at a reduced level for hours. This observation has led to discoveries about how the central vestibular mechanisms adapt to a constant vestibular asymmetry and is a useful model of set-point adaptation or how homeostasis is maintained in response to changes in the internal milieu or the external environment. We review what is known about the effects of stimulation of the vestibular system with high-strength magnetic fields and how the understanding of the mechanism has been refined since it was first proposed. We suggest future ways that magnetic vestibular stimulation might be used to understand vestibular disease and how it might be treated.
Collapse
Affiliation(s)
- Bryan K Ward
- Department of Otolaryngology-Head and Neck Surgery, The Johns Hopkins University School of Medicine , Baltimore, Maryland
| | - Dale C Roberts
- Department of Neurology, The Johns Hopkins University School of Medicine , Baltimore, Maryland
| | - Jorge Otero-Millan
- Department of Neurology, The Johns Hopkins University School of Medicine , Baltimore, Maryland
| | - David S Zee
- Department of Otolaryngology-Head and Neck Surgery, The Johns Hopkins University School of Medicine , Baltimore, Maryland.,Department of Neurology, The Johns Hopkins University School of Medicine , Baltimore, Maryland.,Department of Neuroscience, The Johns Hopkins University School of Medicine , Baltimore, Maryland.,Department of Ophthalmology, The Johns Hopkins University School of Medicine , Baltimore, Maryland
| |
Collapse
|
15
|
Budinger TF, Bird MD. MRI and MRS of the human brain at magnetic fields of 14 T to 20 T: Technical feasibility, safety, and neuroscience horizons. Neuroimage 2018; 168:509-531. [DOI: 10.1016/j.neuroimage.2017.01.067] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2016] [Revised: 01/23/2017] [Accepted: 01/27/2017] [Indexed: 11/16/2022] Open
|
16
|
Mian OS, Li Y, Antunes A, Glover PM, Day BL. Effect of head pitch and roll orientations on magnetically induced vertigo. J Physiol 2016; 594:1051-67. [PMID: 26614577 PMCID: PMC4753258 DOI: 10.1113/jp271513] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2015] [Accepted: 11/19/2015] [Indexed: 11/10/2022] Open
Abstract
KEY POINTS Lying supine in a strong magnetic field, such as in magnetic resonance imaging scanners, can induce a perception of whole-body rotation. The leading hypothesis to explain this invokes a Lorentz force mechanism acting on vestibular endolymph that acts to stimulate semicircular canals. The hypothesis predicts that the perception of whole-body rotation will depend on head orientation in the field. Results showed that the direction and magnitude of apparent whole-body rotation while stationary in a 7 T magnetic field is influenced by head orientation. The data are compatible with the Lorentz force hypothesis of magnetic vestibular stimulation and furthermore demonstrate the operation of a spatial transformation process from head-referenced vestibular signals to Earth-referenced body motion. ABSTRACT High strength static magnetic fields are known to induce vertigo, believed to be via stimulation of the vestibular system. The leading hypothesis (Lorentz forces) predicts that the induced vertigo should depend on the orientation of the magnetic field relative to the head. In this study we examined the effect of static head pitch (-80 to +40 deg; 12 participants) and roll (-40 to +40 deg; 11 participants) on qualitative and quantitative aspects of vertigo experienced in the dark by healthy humans when exposed to the static uniform magnetic field inside a 7 T MRI scanner. Three participants were additionally examined at 180 deg pitch and roll orientations. The effect of roll orientation on horizontal and vertical nystagmus was also measured and was found to affect only the vertical component. Vertigo was most discomforting when head pitch was around 60 deg extension and was mildest when it was around 20 deg flexion. Quantitative analysis of vertigo focused on the induced perception of horizontal-plane rotation reported online with the aid of hand-held switches. Head orientation had effects on both the magnitude and the direction of this perceived rotation. The data suggest sinusoidal relationships between head orientation and perception with spatial periods of 180 deg for pitch and 360 deg for roll, which we explain is consistent with the Lorentz force hypothesis. The effects of head pitch on vertigo and previously reported nystagmus are consistent with both effects being driven by a common vestibular signal. To explain all the observed effects, this common signal requires contributions from multiple semicircular canals.
Collapse
Affiliation(s)
- Omar S Mian
- Sobell Department of Motor Neuroscience and Movement Disorders, Institute of Neurology, University College London, London, UK
| | - Yan Li
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, UK
| | - Andre Antunes
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, UK
| | - Paul M Glover
- Sir Peter Mansfield Imaging Centre, University of Nottingham, Nottingham, UK
| | - Brian L Day
- Sobell Department of Motor Neuroscience and Movement Disorders, Institute of Neurology, University College London, London, UK
| |
Collapse
|
17
|
Schaap K, Portengen L, Kromhout H. Exposure to MRI-related magnetic fields and vertigo in MRI workers. Occup Environ Med 2015; 73:161-6. [PMID: 26561507 DOI: 10.1136/oemed-2015-103019] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2015] [Accepted: 10/21/2015] [Indexed: 11/04/2022]
Abstract
OBJECTIVES Vertigo has been reported by people working around magnetic resonance imaging (MRI) scanners and was found to increase with increasing strength of scanner magnets. This suggests an association with exposure to static magnetic fields (SMF) and/or motion-induced time-varying magnetic fields (TVMF). This study assessed the association between various metrics of shift-long exposure to SMF and TVMF and self-reported vertigo among MRI workers. METHODS We analysed 358 shifts from 234 employees at 14 MRI facilities in the Netherlands. Participants used logbooks to report vertigo experienced during the work day at the MRI facility. In addition, personal exposure to SMF and TVMF was measured during the same shifts, using portable magnetic field dosimeters. RESULTS Vertigo was reported during 22 shifts by 20 participants and was significantly associated with peak and time-weighted average (TWA) metrics of SMF as well as TVMF exposure. Associations were most evident with full-shift TWA TVMF exposure. The probability of vertigo occurrence during a work shift exceeded 5% at peak exposure levels of 409 mT and 477 mT/s and at full-shift TWA levels of 3 mT and 0.6 mT/s. CONCLUSIONS These results confirm the hypothesis that vertigo is associated with exposure to MRI-related SMF and TVMF. Strong correlations between various metrics of shift-long exposure make it difficult to disentangle the effects of SMF and TVMF exposure, or identify the most relevant exposure metric. On the other hand, this also implies that several metrics of shift-long exposure to SMF and TVMF should perform similarly in epidemiological studies on MRI-related vertigo.
Collapse
Affiliation(s)
- Kristel Schaap
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| | - Lützen Portengen
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| | - Hans Kromhout
- Division of Environmental Epidemiology, Institute for Risk Assessment Sciences, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
18
|
Ward BK, Roberts DC, Della Santina CC, Carey JP, Zee DS. Vestibular stimulation by magnetic fields. Ann N Y Acad Sci 2015; 1343:69-79. [PMID: 25735662 DOI: 10.1111/nyas.12702] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Individuals working next to strong static magnetic fields occasionally report disorientation and vertigo. With the increasing strength of magnetic fields used for magnetic resonance imaging studies, these reports have become more common. It was recently learned that humans, mice, and zebrafish all demonstrate behaviors consistent with constant peripheral vestibular stimulation while inside a strong, static magnetic field. The proposed mechanism for this effect involves a Lorentz force resulting from the interaction of a strong static magnetic field with naturally occurring ionic currents flowing through the inner ear endolymph into vestibular hair cells. The resulting force within the endolymph is strong enough to displace the lateral semicircular canal cupula, inducing vertigo and the horizontal nystagmus seen in normal mice and in humans. This review explores the evidence for interactions of magnetic fields with the vestibular system.
Collapse
Affiliation(s)
- Bryan K Ward
- Department of Otolaryngology, Johns Hopkins University School of Medicine, Baltimore, Maryland
| | | | | | | | | |
Collapse
|
19
|
Yu S, Shang P. A review of bioeffects of static magnetic field on rodent models. PROGRESS IN BIOPHYSICS AND MOLECULAR BIOLOGY 2014; 114:14-24. [DOI: 10.1016/j.pbiomolbio.2013.11.002] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2013] [Revised: 10/30/2013] [Accepted: 11/05/2013] [Indexed: 01/11/2023]
|
20
|
Houpt TA, Kwon B, Houpt CE, Neth B, Smith JC. Orientation within a high magnetic field determines swimming direction and laterality of c-Fos induction in mice. Am J Physiol Regul Integr Comp Physiol 2013; 305:R793-803. [PMID: 23720133 DOI: 10.1152/ajpregu.00549.2012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
High-strength static magnetic fields (>7 tesla) perturb the vestibular system causing dizziness, nystagmus, and nausea in humans; and head motion, locomotor circling, conditioned taste aversion, and c-Fos induction in brain stem vestibular nuclei in rodents. To determine the role of head orientation, mice were exposed for 15 min within a 14.1-tesla magnet at six different angles (mice oriented parallel to the field with the head toward B+ at 0°; or pitched rostrally down at 45°, 90°, 90° sideways, 135°, and 180°), followed by a 2-min swimming test. Additional mice were exposed at 0°, 90°, and 180° and processed for c-Fos immunohistochemistry. Magnetic field exposure induced circular swimming that was maximal at 0° and 180° but attenuated at 45° and 135°. Mice exposed at 0° and 45° swam counterclockwise, whereas mice exposed at 135° and 180° swam clockwise. Mice exposed at 90° (with their rostral-caudal axis perpendicular to the magnetic field) did not swim differently than controls. In parallel, exposure at 0° and 180° induced c-Fos in vestibular nuclei with left-right asymmetries that were reversed at 0° vs. 180°. No significant c-Fos was induced after 90° exposure. Thus, the optimal orientation for magnetic field effects is the rostral-caudal axis parallel to the field, such that the horizontal canal and utricle are also parallel to the field. These results have mechanistic implications for modeling magnetic field interactions with the vestibular apparatus of the inner ear (e.g., the model of Roberts et al. of an induced Lorenz force causing horizontal canal cupula deflection).
Collapse
Affiliation(s)
- Thomas A Houpt
- Department of Biological Science, Program in Neuroscience, The Florida State University, Tallahassee, Florida; and
| | | | | | | | | |
Collapse
|
21
|
Hoyer C, Vogt MA, Richter SH, Zaun G, Zahedi Y, Maderwald S, Ladd ME, Winterhager E, Grümmer R, Gass P. Repetitive exposure to a 7 Tesla static magnetic field of mice in utero does not cause alterations in basal emotional and cognitive behavior in adulthood. Reprod Toxicol 2012; 34:86-92. [DOI: 10.1016/j.reprotox.2012.03.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2011] [Revised: 02/10/2012] [Accepted: 03/16/2012] [Indexed: 10/28/2022]
|
22
|
Shaikh AG. A trail of artificial vestibular stimulation: electricity, heat, and magnet. J Neurophysiol 2012; 108:1-4. [PMID: 22457451 DOI: 10.1152/jn.01169.2011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The interaction between the magnetic field of a magnetic resonance imaging (MRI) machine and ion currents within the inner-ear endolymph results in a Lorentz force. This force produces a pressure that pushes on the cupula within the semicircular canals causing nystagmus and vertigo. Here I discuss several implications of this unique and noninvasive way to stimulate the vestibular system in experimental neurophysiology and clinical neurology.
Collapse
Affiliation(s)
- Aasef G Shaikh
- Department of Neurology, Case Western Reserve University, Cleveland, Ohio, USA.
| |
Collapse
|
23
|
MRI magnetic field stimulates rotational sensors of the brain. Curr Biol 2011; 21:1635-40. [PMID: 21945276 DOI: 10.1016/j.cub.2011.08.029] [Citation(s) in RCA: 137] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2011] [Revised: 07/22/2011] [Accepted: 08/12/2011] [Indexed: 11/22/2022]
Abstract
Vertigo in and around magnetic resonance imaging (MRI) machines has been noted for years [1, 2]. Several mechanisms have been suggested to explain these sensations [3, 4], yet without direct, objective measures, the cause is unknown. We found that all of our healthy human subjects developed a robust nystagmus while simply lying in the static magnetic field of an MRI machine. Patients lacking labyrinthine function did not. We use the pattern of eye movements as a measure of vestibular stimulation to show that the stimulation is static (continuous, proportional to static magnetic field strength, requiring neither head movement nor dynamic change in magnetic field strength) and directional (sensitive to magnetic field polarity and head orientation). Our calculations and geometric model suggest that magnetic vestibular stimulation (MVS) derives from a Lorentz force resulting from interaction between the magnetic field and naturally occurring ionic currents in the labyrinthine endolymph fluid. This force pushes on the semicircular canal cupula, leading to nystagmus. We emphasize that the unique, dual role of endolymph in the delivery of both ionic current and fluid pressure, coupled with the cupula's function as a pressure sensor, makes magnetic-field-induced nystagmus and vertigo possible. Such effects could confound functional MRI studies of brain behavior, including resting-state brain activity.
Collapse
|
24
|
Houpt TA, Cassell J, Carella L, Neth B, Smith JC. Head tilt in rats during exposure to a high magnetic field. Physiol Behav 2011; 105:388-93. [PMID: 21903121 DOI: 10.1016/j.physbeh.2011.08.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2011] [Revised: 08/23/2011] [Accepted: 08/25/2011] [Indexed: 12/01/2022]
Abstract
During exposure to high strength static magnetic fields, humans report vestibular symptoms such as vertigo, apparent motion, and nausea. Rodents also show signs of vestibular perturbation after magnetic field exposure at 7 tesla (T) and above, such as locomotor circling, activation of vestibular nuclei, and acquisition of conditioned taste aversions. We hypothesized that the acute effects of the magnetic field might be seen as changes in head position during exposure within the magnet. Using a yoked restraint tube that allowed movement of the head and neck, we found that rats showed an immediate and persistent deviation of the head during exposure to a static 14.1 T magnetic field. The direction of the head tilt was dependent on the orientation of the rat in the magnetic field (B), such that rats oriented head-up (snout towards B+) showed a rightward tilt of the head, while rats oriented head-down (snout towards B-) showed a leftward tilt of the head. The tilt of the head during magnet exposure was opposite to the direction of locomotor circling immediately after exposure observed previously. Rats exposed in the yoked restraint tube showed significantly more locomotor circling compared to rats exposed with the head restrained. There was little difference in CTA magnitude or extinction rate, however. The deviation of the head was seen when the rats were motionless within the homogenous static field; movement through the field or exposure to the steep gradients of the field was not necessary to elicit the apparent vestibulo-collic reflex.
Collapse
Affiliation(s)
- Thomas A Houpt
- Department of Biological Science, King Life Sciences Building, The Florida State University, Tallahassee, FL 32306-4295, United States.
| | | | | | | | | |
Collapse
|