1
|
Pick FC, Fish KE, Boxall JB. Assimilable organic carbon cycling within drinking water distribution systems. WATER RESEARCH 2021; 198:117147. [PMID: 33962239 DOI: 10.1016/j.watres.2021.117147] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 04/07/2021] [Accepted: 04/10/2021] [Indexed: 06/12/2023]
Abstract
A new conceptual model to describe and understand the role of assimilable organic carbon (AOC) within drinking water distribution systems is proposed. The impact of AOC on both drinking water biofilm and water quality was studied using bespoke pipe loop experimental facilities installed at three carefully selected operational water treatment works. Integrated physical, chemical and biological monitoring was undertaken that highlights the central role of biofilms in AOC cycling, forming the basis of the new conceptual model. Biofilms formed under high AOC conditions were found to pose the highest discoloration response, generating a turbidity (4.3 NTU) and iron (241.5 µg/l) response sufficient to have caused regulatory failures from only 20 m of pipe in only 12 months of operation. This new knowledge of the role of biofilms in AOC cycling, and ultimately impacts on water quality, can be used to inform management and help ensure the supply of high-quality, biostable drinking water.
Collapse
Affiliation(s)
- Frances C Pick
- Sheffield Water Center, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, United Kingdom.
| | - Katherine E Fish
- Sheffield Water Center, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, United Kingdom
| | - Joby B Boxall
- Sheffield Water Center, Department of Civil and Structural Engineering, The University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
2
|
Sousi M, Salinas-Rodriguez SG, Liu G, Schippers JC, Kennedy MD, van der Meer W. Measuring Bacterial Growth Potential of Ultra-Low Nutrient Drinking Water Produced by Reverse Osmosis: Effect of Sample Pre-treatment and Bacterial Inoculum. Front Microbiol 2020; 11:791. [PMID: 32411118 PMCID: PMC7201026 DOI: 10.3389/fmicb.2020.00791] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2019] [Accepted: 04/02/2020] [Indexed: 12/20/2022] Open
Abstract
Measuring bacterial growth potential (BGP) involves sample pre-treatment and inoculation, both of which may introduce contaminants in ultra-low nutrient water (e.g., remineralized RO permeate). Pasteurization pre-treatment may lead to denaturing of nutrients, and membrane filtration may leach/remove nutrients into/from water samples. Inoculating remineralized RO permeate samples with natural bacteria from conventional drinking water leads to undesired nutrient addition, which could be avoided by using the remineralized RO permeate itself as inoculum. Therefore, this study examined the effect of pasteurization and membrane filtration on the BGP of remineralized RO permeate. In addition, the possibility of using bacteria from remineralized RO permeate as inoculum was investigated by evaluating their ability to utilize organic carbon that is readily available (acetate, glucose) or complex (laminarin, gelatin, and natural dissolved organic carbon), as compared with bacteria from conventional drinking water. The results showed that membrane filtration pre-treatment increased (140-320%) the BGP of remineralized RO permeate despite the extensive soaking and flushing of filters (>350 h), whereas no effect was observed on the BGP of conventional drinking water owing to its high nutrient content. Pasteurization pre-treatment had insignificant effects on the BGP of both water types. Remineralized RO permeate bacteria showed limitations in utilizing complex organic carbon compared with bacteria from conventional drinking water. In conclusion, the BGP bioassay for ultra-low nutrient water (e.g., remineralized RO permeate) should consider pasteurization pre-treatment. However, an inoculum comprising bacteria from remineralized RO permeate is not recommended as the bacterial consortium was shown to be limited in terms of the compounds they could utilize for growth.
Collapse
Affiliation(s)
- Mohaned Sousi
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
- Faculty of Science and Technology, University of Twente, Enschede, Netherlands
| | - Sergio G. Salinas-Rodriguez
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, China
- Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Delft, Netherlands
| | - Jan C. Schippers
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
| | - Maria D. Kennedy
- Department of Environmental Engineering and Water Technology, IHE Delft Institute for Water Education, Delft, Netherlands
- Department of Water Management, Faculty of Civil Engineering and Geoscience, Delft University of Technology, Delft, Netherlands
| | - Walter van der Meer
- Faculty of Science and Technology, University of Twente, Enschede, Netherlands
- Oasen Drinkwater, Gouda, Netherlands
| |
Collapse
|
3
|
Application of enhanced assimilable organic carbon method across operational drinking water systems. PLoS One 2019; 14:e0225477. [PMID: 31809502 PMCID: PMC6897430 DOI: 10.1371/journal.pone.0225477] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2019] [Accepted: 11/05/2019] [Indexed: 11/19/2022] Open
Abstract
Assimilable organic carbon (AOC) is known to correlate with microbial growth, which can consequently degrade drinking water quality. Despite this, there is no standardised AOC test that can be applied to drinking water distribution systems (DWDS). Herein we report the development of a quick, robust AOC that incorporates known strains Pseudomonas fluorescens strain P-17 and Spirillum strain NOX, a higher inoculum volume and enumeration using flow cytometry to generate a quicker (total test time reduced from 14 to 8 days), robust method. We apply the developed AOC test to twenty drinking water treatment works (WTW) to validate the method reproducibility and resolution across a wide range of AOC concentrations. Subsequently, AOC was quantified at 32 sample points, over four DWDS, for a year in order to identify sinks and sources of AOC in operative networks. Application of the developed AOC protocol provided a previously unavailable insight and novel evidence of pipes and service reservoirs exhibiting different AOC and regrowth behaviour. Observed correlations between AOC and microbial growth highlight the importance of monitoring AOC as an integral part of managing drinking water quality at the consumers tap.
Collapse
|
4
|
Chen Z, Yu T, Ngo HH, Lu Y, Li G, Wu Q, Li K, Bai Y, Liu S, Hu HY. Assimilable organic carbon (AOC) variation in reclaimed water: Insight on biological stability evaluation and control for sustainable water reuse. BIORESOURCE TECHNOLOGY 2018; 254:290-299. [PMID: 29398290 DOI: 10.1016/j.biortech.2018.01.111] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2017] [Revised: 01/20/2018] [Accepted: 01/22/2018] [Indexed: 05/05/2023]
Abstract
This review highlights the importance of conducting biological stability evaluation due to water reuse progression. Specifically, assimilable organic carbon (AOC) has been identified as a practical indicator for microbial occurrence and regrowth which ultimately influence biological stability. Newly modified AOC bioassays aimed for reclaimed water are introduced. Since elevated AOC levels are often detected after tertiary treatment, the review emphasizes that actions can be taken to either limit AOC levels prior to disinfection or conduct post-treatment (e.g. biological filtration) as a supplement to chemical oxidation based approaches (e.g. ozonation and chlorine disinfection). During subsequent distribution and storage, microbial community and possible microbial regrowth caused by complex interactions are discussed. It is suggested that microbial surveillance, AOC threshold values, real-time field applications and surrogate parameters could provide additional information. This review can be used to formulate regulatory plans and strategies, and to aid in deriving relevant control, management and operational guidance.
Collapse
Affiliation(s)
- Zhuo Chen
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, PR China
| | - Tong Yu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Huu Hao Ngo
- School of Civil and Environmental Engineering, University of Technology Sydney, Broadway, NSW 2007, Australia
| | - Yun Lu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Guoqiang Li
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Qianyuan Wu
- Key Laboratory of Microorganism Application and Risk Control of Shenzhen, Graduate School at Shenzhen, Tsinghua University, Shenzhen 518055, PR China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China
| | - Kuixiao Li
- Research and Development Center, Beijing Drainage Group Co., Ltd, Beijing 100124, PR China
| | - Yu Bai
- Research and Development Center, Beijing Drainage Group Co., Ltd, Beijing 100124, PR China
| | - Shuming Liu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China
| | - Hong-Ying Hu
- Environmental Simulation and Pollution Control State Key Joint Laboratory, State Environmental Protection Key Laboratory of Microorganism Application and Risk Control (SMARC), School of Environment, Tsinghua University, Beijing 100084, PR China; Shenzhen Environmental Science and New Energy Technology Engineering Laboratory, Tsinghua-Berkeley Shenzhen Institute, Shenzhen 518055, PR China.
| |
Collapse
|