1
|
Cao R, Zhang S, Li L, Qiu P, Xu H, Cao Y. Accuracy of intraoral scanning versus conventional impressions for partial edentulous patients with maxillary defects. Sci Rep 2023; 13:16773. [PMID: 37798354 PMCID: PMC10556061 DOI: 10.1038/s41598-023-44033-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 10/03/2023] [Indexed: 10/07/2023] Open
Abstract
This study aimed to evaluate the accuracy of digital dental impressions obtained by intraoral scanning (IOS) for partial edentulous patients with maxillary defects by comparing them with conventional impression techniques. Ten subjects underwent an experimental procedure where three ceramic blocks were affixed to the healthy palate mucosa. Digital dental impressions were captured using IOS and subsequently imported into software. Conventional impressions obtained by silicone rubber were also taken and scanned. Linear distance and best-fit algorithm measurements were performed using conventional impression techniques as the reference. Twenty impressions were analyzed, which included 30 pairs of linear distances and 10 best-fit algorithm measurements. Regarding linear distance, paired two-sample t-test demonstrated no significant differences between IOS and model scanning in groups A and C, whereas significant differences were found in group B (P < 0.05). Additionally, ANOVA revealed significant differences among the groups (P < 0.05). No significant differences were found for the best-fit algorithm measurement of the dentition. IOS can provide accurate impressions for partial edentulous patients with maxillary defects and its accuracy was found to be comparable with conventional impression techniques. A functional impression may be needed to ensure accurate reproduction of soft and hard tissues in defect or flap areas.
Collapse
Affiliation(s)
- Rongkai Cao
- Department of Stomatology, The First Affiliated Hospital, Fujian Medical University, No. 20, Chazhong Rd, Fuzhou, 350005, Fujian, China
- School & Hospital of Stomatology, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji University, Shanghai, 200072, China
| | - Shilei Zhang
- Department of Stomatology, The First Affiliated Hospital, Fujian Medical University, No. 20, Chazhong Rd, Fuzhou, 350005, Fujian, China
- General Dentistry, Stomatological Hospital of Xiamen Medical College, Xiamen, 361008, China
| | - Lishan Li
- Department of Stomatology, The First Affiliated Hospital, Fujian Medical University, No. 20, Chazhong Rd, Fuzhou, 350005, Fujian, China
- Department of Stomatology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, China
| | - Piaopiao Qiu
- School & Hospital of Stomatology, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji University, Shanghai, 200072, China
| | - Hui Xu
- School & Hospital of Stomatology, Shanghai Engineering Research Center of Tooth Restoration and Regeneration, Tongji University, Shanghai, 200072, China
| | - Yujie Cao
- Department of Stomatology, The First Affiliated Hospital, Fujian Medical University, No. 20, Chazhong Rd, Fuzhou, 350005, Fujian, China.
- Department of Stomatology, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, 350212, China.
| |
Collapse
|
2
|
Jovanović M, Stojanović S, Todorović K, Obradović R, Igić M, Stojković B, Gligorijević N, Spasić M, Jovanović G. Early use of partial acrylic denture obturator in the postoperative treatment of bone defects after marsupialisation of large jaw cysts. ACTA STOMATOLOGICA NAISSI 2019. [DOI: 10.5937/asn1980970j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022] Open
|