1
|
Panuccio G, Abdelwahed YS, Carabetta N, Landmesser U, De Rosa S, Torella D. The Role of Coronary Imaging in Chronic Total Occlusions: Applications and Future Possibilities. J Cardiovasc Dev Dis 2024; 11:295. [PMID: 39330353 PMCID: PMC11432693 DOI: 10.3390/jcdd11090295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2024] [Revised: 09/17/2024] [Accepted: 09/18/2024] [Indexed: 09/28/2024] Open
Abstract
Chronic total occlusions (CTOs) represent a challenging scenario in coronary artery disease (CAD). The prevalence of CTOS in patients undergoing coronary angiography underscores the need for effective diagnostic and therapeutic strategies. Coronary angiography, while essential, offers limited insights into lesion morphology, vessel course, and myocardial viability. In contrast, coronary imaging techniques-including optical coherence tomography (OCT), intravascular ultrasound (IVUS), and coronary computed tomography angiography (CCTA)-provide comprehensive insights for each stage of CTO percutaneous coronary intervention (PCI). OCT facilitates the assessment of plaque morphology and stent optimization, despite low evidence and several limitations in CTO-PCI. IVUS offers deeper penetration, allowing managing proximal cap scenarios and guiding subintimal navigation. CCTA provides a non-invasive, three-dimensional view of coronary anatomy, enabling the precise evaluation of myocardial mass at risk and detailed procedural planning. Despite their individual limitations, these imaging modalities have enhanced the success rates of CTO-PCI, thus reducing procedural and long-term complications and improving patient outcomes. The future of CTO management lies in further technological advancements, including hybrid imaging, artificial intelligence (AI) integration, and improved fusion imaging. These innovations promise to refine procedural precision and personalize interventions, ultimately improving the care of patients with complex coronary artery disease.
Collapse
Affiliation(s)
- Giuseppe Panuccio
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy;
- Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, 12200 Berlin, Germany; (Y.S.A.); (U.L.)
| | - Youssef S. Abdelwahed
- Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, 12200 Berlin, Germany; (Y.S.A.); (U.L.)
| | - Nicole Carabetta
- Department of Medical and Surgical Sciences, Magna Graecia University, 88100 Catanzaro, Italy; (N.C.); (S.D.R.)
| | - Ulf Landmesser
- Department of Cardiology, Angiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité, 12200 Berlin, Germany; (Y.S.A.); (U.L.)
| | - Salvatore De Rosa
- Department of Medical and Surgical Sciences, Magna Graecia University, 88100 Catanzaro, Italy; (N.C.); (S.D.R.)
| | - Daniele Torella
- Department of Experimental and Clinical Medicine, Magna Graecia University, 88100 Catanzaro, Italy;
| |
Collapse
|
2
|
Tang X, Zhang Y, Wang T, Ma Y, Shi H, Yin R, Zou P, Cao J, Pan C. Image quality and diagnostic accuracy of different dosages of iodixanol in computed tomography angiography and perfusion of overweight patients with coronary artery stenosis: A feasibility study. Med Eng Phys 2022; 110:103818. [PMID: 35618562 DOI: 10.1016/j.medengphy.2022.103818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Revised: 04/11/2022] [Accepted: 05/09/2022] [Indexed: 01/18/2023]
Abstract
OBJECTIVES Iodixanol contrast media with different doses using computed tomography angiography (CTA) and perfusion (CTP) to diagnose coronary artery disease (CAD) in overweight patients lacks assessment. Our study compared iodixanol 320 mg I/ml and 270 mg I/ml on image quality and accuracy of CTA combined CTP (CTA-CTP) to diagnose CAD. METHODS Overweight patients with suspected of CAD were randomized into iodixanol 270 group (received iodixanol 270 mg I/ml) and iodixanol 320 group (received iodixanol 320 mg I/ml). Based on these characteristics data, receiver operating characteristic (ROC) curve and corresponding area under the curve (AUC) were plotted to assess the sensitivity and specificity of the two administrations. RESULTS The subjective definition score, signal to noise ratio, and CT value of aorta in iodixanol 320 group were higher than iodixanol 270 group. In iodixanol 270 group: the image exhibited a normal state of both vessels and myocardial perfusion; and the AUC, specificity, and sensitivity were 0.376, 66.67, and 80.46, respectively. In iodixanol 320 group: the image exhibited a diameter stenosis in right coronary artery and myocardial infarction of inferior wall and proximal inferior wall septum, as well as myocardial perfusion defects; and the AUC, specificity, and sensitivity in iodixanol 320 group were 0.824, 75.00, and 89.87, respectively. CONCLUSION Accuracy and image quality of iodixanol 320 mg I/ml in the diagnosis of CAD with CTA-CTP was higher than using iodixanol 270 mg I/ml.
Collapse
Affiliation(s)
- Xiaoqiang Tang
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Yong Zhang
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Tao Wang
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Yi Ma
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Haifeng Shi
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Ruohan Yin
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Ping Zou
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Jian Cao
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China
| | - Changjie Pan
- Department of Radiology, The Affiliated Changzhou No.2 People's Hospital of Nanjing Medical University, Changzhou 213164, China.
| |
Collapse
|
3
|
He W, Chen X, Hu R, Sun W, Tan W. Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging. Front Surg 2022; 9:862697. [PMID: 35449554 PMCID: PMC9018106 DOI: 10.3389/fsurg.2022.862697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2022] [Accepted: 02/21/2022] [Indexed: 11/13/2022] Open
Abstract
Objective To explore the influence of a contrast agent injection scheme customized by dual-source CT based on automatic tube voltage technology on coronary imaging image quality and radiation dose. Methods A total of 205 patients who underwent coronary CT angiography (CCTA) in our hospital from June 2021 to September 2021 were selected. 105 patients in the control group who underwent routine scanning according to body mass (BMI) and 100 patients in the observation group who set tube voltage and contrast agent dosage according to automatic tube voltage selection technology. CT values of the aortic root (AO); left anterior descending (LAD) branch; proximal, middle, and distal segments of the right coronary artery (RCA); and proximal and distal segments of left circumflex (LCX) branch were measured. We calculated the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the image. Image quality scoring and effective dose (ED) calculation were carried out. Results There was no significant difference in the CT value, SNR value, and CNR value of each part of the artery between the two groups (P > 0.05). Image quality scores of the control group and the observation group were 1.28 ± 0.25 and 1.25 ± 0.23, respectively, and there was no significant difference in scores (P > 0.05). In the control group, the dosage of comparator was 43.81 ± 6.74 ml, and the ED was 4.92 ± 1.26 mSv. The dosage of contrast agent in the observation group was 34.23 ± 6.39 ml, and ED was 3.05 ± 0.94 mSv. The dosage of contrast agent and ED in the observation group were lower than those in the control group (P < 0.05). Conclusion The contrast agent injection scheme customized by dual-source CT based on automatic tube voltage technology can meet the clinical requirements of coronary image quality, reduce the radiation dose and contrast agent consumption, and help doctors choose a more accurate and reasonable examination scheme, which has certain clinical application value.
Collapse
Affiliation(s)
- Weiling He
- Department of Radiology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Xin Chen
- Diagnostic Radiology Department, Hunan Cancer Hospital, Changsha, China
| | - Rui Hu
- Interventional Vascular Surgery Department, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Wenjie Sun
- Department of Radiology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, Changsha, China
| | - Weili Tan
- Diagnostic Radiology Department, Hunan Cancer Hospital, Changsha, China
- *Correspondence: Weili Tan
| |
Collapse
|
4
|
Sun J, Li H, Li J, Cao Y, Zhou Z, Li M, Peng Y. Performance evaluation of using shorter contrast injection and 70 kVp with deep learning image reconstruction for reduced contrast medium dose and radiation dose in coronary CT angiography for children: a pilot study. Quant Imaging Med Surg 2021; 11:4162-4171. [PMID: 34476196 DOI: 10.21037/qims-20-1159] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Accepted: 04/22/2021] [Indexed: 01/22/2023]
Abstract
Background Iterative reconstruction algorithms are often used to reduce image noise in low-dose coronary computed tomography angiography (CCTA) but encounter limitations. The newly introduced deep learning image reconstruction (DLIR) algorithm may provide new opportunities. We assessed the image quality and diagnostic performance of DLIR in low radiation dose and contrast medium dose CCTA of pediatric patients with 70 kVp and a shortened injection protocol. Methods This was a prospective study. A total of 27 consecutive arrhythmic pediatric patients were enrolled in the study group and underwent CCTA using a prospective ECG-triggered single-beat protocol: tube voltage 70 kVp, automatic tube current modulation for a noise index (NI) of 22, and contrast dose of 0.4-0.6 mL/kg. Images were reconstructed with DLIR. They were compared with 27 matched patients in the control group scanned with 80 kVp, a lower NI setting (NI =19), and a higher contrast dose (0.8-1.2 mL/kg). The images in the control group were reconstructed using the adaptive statistical iterative reconstruction (ASIR-V) algorithm. The image contrast, image quality, and diagnostic confidence were assessed by 2 experienced radiologists using a 5-point scale (1: nondiagnostic and 5: excellent). The CT value and standard deviation of the aorta and perivascular tissue were measured, and the contrast-to-noise ratio (CNR) for the aorta was calculated. The contrast medium and radiation doses were compared. Results The study and control groups had similar image contrast scores (4.75±0.57 vs. 4.78±0.42), image quality scores (3.67±0.47 vs. 3.44±0.51), and diagnostic confidence (4.74±0.44 vs. 4.74±0.45) (all P>0.05). There was an adequate enhancement in the aorta (614.74±127.73 vs. 705.89±111.20 HU) and similar CNR (20.34±4.64 vs. 20.99±4.14) in both groups. The image noise of the study group was lower in the aorta (30.61±3.88 vs. 34.77±3.49) and similar in perivascular tissue (27.66±6.24 vs. 27.55±3.33) compared with the control group. The study group reduced the total contrast medium dose by 53% to 15.07±3.68 mL and radiation dose by 36% to 0.57±0.31 mSv. Conclusions The DLIR algorithm in CCTA for children using 70 kVp tube voltage with a shortened contrast medium injection protocol maintains image quality and diagnostic confidence while significantly reducing contrast medium dose and radiation dose compared with the use of the conventional CCTA protocol.
Collapse
Affiliation(s)
- Jihang Sun
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Haoyan Li
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | | | - Yongli Cao
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| | - Zuofu Zhou
- Department of Radiology, Fujian Provincial Maternity and Children's Hospital, Affiliated Hospital of Fujian Medical University, Fuzhou, China
| | - Michelle Li
- Department of Human Biology, Stanford University, CA, USA
| | - Yun Peng
- Imaging Center, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China
| |
Collapse
|