Goto S, Hayashi H, Yamaguchi H, Sekiguchi H, Akino R, Shimizu M. Signal-stabilized Al2O3:C-OSL dosimeter “checking chip” for correcting OSL reader sensitivity variation. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2022.106893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
2
|
Gasparian PBG, Malthez ALMC, Campos LL. Using the optically stimulated luminescence technique for one- and two-dimensional dose mapping: a brief review. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac9030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 09/07/2022] [Indexed: 11/12/2022]
Abstract
Abstract
In respect of radiation dosimetry, several applications require dose distribution verification rather than absolute dosimetry. Most protocols use radiological and radiochromic films and ionization chambers or diode arrays for dose mapping. The films are disposable which causes the precision of the results dependent on film production variability. The measurements with arrays of ionization chambers or diodes mainly lack spatial resolution. This review aims to provide an overview of the use of optically stimulated luminescence detectors (OSLDs) for one-dimensional (1D) and two-dimensional (2D) dose mapping in different applications. It reviews the ideas, OSL materials, and applications related to the assessment of dose distribution using OSLDs in the form of film or ceramic plate (BeO). Additionally, it reviews research published in the international scientific literature from 1998 to 2021. As an outcome, a table containing the main characteristics of each relevant paper is shown. The results section was divided by the type of OSL material, and we briefly described the principal findings and the significant developments of each mentioned study such as film production and OSL reader assembly. The purpose of this study was to present an overview of the main findings of several research groups on the use of OSLD in the form of film or plate for 1D and 2D dose mapping. Finally, the potential future development of dose mapping using OSLD films was outlined.
Collapse
|
3
|
Romano F, Bailat C, Jorge PG, Lerch MLF, Darafsheh A. Ultra‐high dose rate dosimetry: challenges and opportunities for FLASH radiation therapy. Med Phys 2022; 49:4912-4932. [PMID: 35404484 PMCID: PMC9544810 DOI: 10.1002/mp.15649] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 02/03/2022] [Accepted: 02/20/2022] [Indexed: 11/11/2022] Open
Affiliation(s)
- Francesco Romano
- Istituto Nazionale di Fisica Nucleare Sezione di Catania Catania Italy
| | - Claude Bailat
- Institute of Radiation Physics Lausanne University Hospital Lausanne University Switzerland
| | - Patrik Gonçalves Jorge
- Institute of Radiation Physics Lausanne University Hospital Lausanne University Switzerland
- Department of Radiation Oncology Lausanne University Hospital Lausanne Switzerland
- Radio‐Oncology Laboratory DO/CHUV Lausanne University Hospital Lausanne Switzerland
| | | | - Arash Darafsheh
- Department of Radiation Oncology Washington University School of Medicine St. Louis MO 63110 USA
| |
Collapse
|
4
|
OSL dosimeters for dental panoramic radiography. Appl Radiat Isot 2018; 142:32-37. [DOI: 10.1016/j.apradiso.2018.09.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2018] [Revised: 09/08/2018] [Accepted: 09/10/2018] [Indexed: 11/19/2022]
|
5
|
Characterization of Ce-doped lithium borosilicate glasses as tissue-equivalent phosphors for radiation measurements. RADIAT MEAS 2018. [DOI: 10.1016/j.radmeas.2018.02.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
6
|
Gaza R, Kroupa M, Rios R, Stoffle N, Benton ER, Semones EJ. Comparison of novel active semiconductor pixel detectorwith passive radiation detectors during the NASA Orion Exploration Flight Test 1 (EFT-1). RADIAT MEAS 2017. [DOI: 10.1016/j.radmeas.2017.03.041] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
7
|
Yusuf M, Alothmany N, Abdulrahman Kinsara A. Organ dose measurement using Optically Stimulated Luminescence Detector (OSLD) during CT examination. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.05.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
Sensitivity and stability of optically stimulated luminescence dosimeters with filled deep electron/hole traps under pre-irradiation and bleaching conditions. Phys Med 2017; 38:81-87. [PMID: 28610701 DOI: 10.1016/j.ejmp.2017.05.057] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 03/14/2017] [Accepted: 05/10/2017] [Indexed: 11/20/2022] Open
Abstract
PURPOSE We aimed to evaluate the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps, and determine the optimal bleaching conditions for these OSLDs to minimize the changes in dose sensitivity or linearity according to the accumulated dose. METHODS InLight nanoDots were used as OSLDs. The OSLDs were first pre-irradiated at a dose greater than 5kGy to fill the deep electron and hole traps, and then bleached (OSLDfull). OSLDfull characteristics were investigated in terms of the full bleaching, fading, regeneration of luminescence, dose linearity, and dose sensitivity with various bleaching conditions. For comparison, OSLDs with un-filled deep electron/hole traps (OSLDempty) were investigated in the same manner. RESULTS The fading for OSLDfull exhibited stable signals after 10min, for 1 and 10Gy. The mean supra-linear index values for OSLDfull were 1.001±0.001 for doses from 2 to 10Gy. Small variations in dose sensitivity were obtained for OSLDfull within standard deviations of 0.85% and 0.71%, whereas those of OSLDempty decreased by 2.3% and 4.2% per 10Gy for unfiltered and filtered bleaching devices, respectively. CONCLUSIONS Under the bleaching conditions determined in this study, clinical dosimetry with OSLDfull is highly stable, minimizing the changes in dose sensitivity or linearity for the clinical dose.
Collapse
|
9
|
Mail N, Yusuf M, Alothmany N, Kinsara AA, Abdulkhaliq F, Ghamdi SM, Saoudi A. A methodology for on-board CBCT imaging dose using optically stimulated luminescence detectors. J Appl Clin Med Phys 2016; 17:482-499. [PMID: 27685143 PMCID: PMC5874125 DOI: 10.1120/jacmp.v17i5.6378] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 06/07/2016] [Accepted: 05/24/2016] [Indexed: 11/23/2022] Open
Abstract
Cone‐beam computed tomography CBCT systems are used in radiation therapy for patient alignment and positioning. The CBCT imaging procedure for patient setup adds substantial radiation dose to patient's normal tissue. This study presents a complete procedure for the CBCT dosimetry using the InLight optically‐stimulated‐luminescence (OSL) nanoDots. We report five dose parameters: the mean slice dose (DMSD); the cone beam dose index (CBDIW); the mean volume dose (DMVD); point‐dose profile, D(FOV); and the off‐field Dose. In addition, CBCT skin doses for seven pelvic tumor patients are reported. CBCT‐dose measurement was performed on a custom‐made cylindrical acrylic body phantom (50 cm length, 32 cm diameter). We machined 25 circular disks (2 cm thick) with grooves and holes to hold OSL‐nanoDots. OSLs that showed similar sensitivities were selected and calibrated against a Farmer‐type ionization‐chamber (0.6 CT) before being inserted into the grooves and holes. For the phantom scan, a standard CBCT‐imaging protocol (pelvic sites: 125 kVp, 80 mA and 25 ms) was used. Five dose parameters were quantified: DMSD, CBDIW, DMVD, D(FOV), and the off‐field dose. The DMSD for the central slice was 31.1±0.85 mGy, and CBDIW was 34.5±0.6 mGy at 16 cm FOV. The DMVD was 25.6±1.1 mGy. The off‐field dose was 10.5 mGy. For patients, the anterior and lateral skin doses attributable to CBCT imaging were 39.04±4.4 and 27.1±1.3 mGy, respectively. OSL nanoDots were convenient to use in measuring CBCT dose. The method of selecting the nanoDots greatly reduced uncertainty in the OSL measurements. Our detailed calibration procedure and CBCT dose measurements and calculations could prove useful in developing OSL routines for CBCT quality assessment, which in turn gives them the property of high spatial resolution, meaning that they have the potential for measurement of dose in regions of severe dose‐gradients. PACS number(s): 87.57.‐s, 87.57.Q, 87.57.uq
Collapse
Affiliation(s)
- Noor Mail
- King Abdullah International Medical Research Center (KAIMRC); National Guard Health Affairs.
| | | | | | | | | | | | | |
Collapse
|
10
|
Flint DB, Granville DA, Sahoo N, McEwen M, Sawakuchi GO. Ionization density dependence of the curve shape and ratio of blue to UV emissions of Al 2 O 3 :C optically stimulated luminescence detectors exposed to 6-MV photon and therapeutic proton beams. RADIAT MEAS 2016. [DOI: 10.1016/j.radmeas.2016.02.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
11
|
Granville DA, Sahoo N, Sawakuchi GO. Simultaneous measurements of absorbed dose and linear energy transfer in therapeutic proton beams. Phys Med Biol 2016; 61:1765-79. [DOI: 10.1088/0031-9155/61/4/1765] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
|
12
|
Tuncel N. Assessment of patient dose in medical processes by in-vivodose measuring devices: A review. EPJ WEB OF CONFERENCES 2016. [DOI: 10.1051/epjconf/201612804002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
13
|
Scarboro SB, Cody D, Alvarez P, Followill D, Court L, Stingo FC, Zhang D, McNitt-Gray M, Kry SF. Characterization of the nanoDot OSLD dosimeter in CT. Med Phys 2015; 42:1797-807. [PMID: 25832070 DOI: 10.1118/1.4914398] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The extensive use of computed tomography (CT) in diagnostic procedures is accompanied by a growing need for more accurate and patient-specific dosimetry techniques. Optically stimulated luminescent dosimeters (OSLDs) offer a potential solution for patient-specific CT point-based surface dosimetry by measuring air kerma. The purpose of this work was to characterize the OSLD nanoDot for CT dosimetry, quantifying necessary correction factors, and evaluating the uncertainty of these factors. METHODS A characterization of the Landauer OSL nanoDot (Landauer, Inc., Greenwood, IL) was conducted using both measurements and theoretical approaches in a CT environment. The effects of signal depletion, signal fading, dose linearity, and angular dependence were characterized through direct measurement for CT energies (80-140 kV) and delivered doses ranging from ∼5 to >1000 mGy. Energy dependence as a function of scan parameters was evaluated using two independent approaches: direct measurement and a theoretical approach based on Burlin cavity theory and Monte Carlo simulated spectra. This beam-quality dependence was evaluated for a range of CT scanning parameters. RESULTS Correction factors for the dosimeter response in terms of signal fading, dose linearity, and angular dependence were found to be small for most measurement conditions (<3%). The relative uncertainty was determined for each factor and reported at the two-sigma level. Differences in irradiation geometry (rotational versus static) resulted in a difference in dosimeter signal of 3% on average. Beam quality varied with scan parameters and necessitated the largest correction factor, ranging from 0.80 to 1.15 relative to a calibration performed in air using a 120 kV beam. Good agreement was found between the theoretical and measurement approaches. CONCLUSIONS Correction factors for the measurement of air kerma were generally small for CT dosimetry, although angular effects, and particularly effects due to changes in beam quality, could be more substantial. In particular, it would likely be necessary to account for variations in CT scan parameters and measurement location when performing CT dosimetry using OSLD.
Collapse
Affiliation(s)
- Sarah B Scarboro
- The University of Texas MD Anderson Cancer Center, Houston, Texas 77030; Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030; and The Methodist Hospital, Houston, Texas 77030
| | - Dianna Cody
- The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030
| | - Paola Alvarez
- The University of Texas MD Anderson Cancer Center, Houston, Texas 77030
| | - David Followill
- The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030
| | - Laurence Court
- The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030
| | - Francesco C Stingo
- The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030
| | - Di Zhang
- Biomedical Physics Graduate Program, David Geffen School of Medicine at UCLA, Los Angeles, California 90095 and Toshiba American Medical Systems, Tustin, California 92780
| | - Michael McNitt-Gray
- The Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, California 90095
| | - Stephen F Kry
- The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 and Graduate School of Biomedical Sciences, The University of Texas Health Science Center Houston, Houston, Texas 77030
| |
Collapse
|
14
|
Radiation dose measurements of an on-board imager X-ray unit using optically-stimulated luminescence dosimeters. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2015; 38:665-9. [DOI: 10.1007/s13246-015-0386-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2014] [Accepted: 10/12/2015] [Indexed: 12/11/2022]
|
15
|
Hasegawa H, Sato M, Tanaka H. Evaluation of an X-Ray Dose Profile Derived from an Optically Stimulated Luminescent Dosimeter during Computed Tomographic Fluoroscopy. PLoS One 2015; 10:e0132154. [PMID: 26151914 PMCID: PMC4494858 DOI: 10.1371/journal.pone.0132154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Accepted: 06/10/2015] [Indexed: 11/19/2022] Open
Abstract
The purpose of this study was to evaluate scatter radiation dose to the subject surface during X-ray computed tomography (CT) fluoroscopy using the integrated dose ratio (IDR) of an X-ray dose profile derived from an optically stimulated luminescent (OSL) dosimeter. We aimed to obtain quantitative evidence supporting the radiation protection methods used during previous CT fluoroscopy. A multislice CT scanner was used to perform this study. OSL dosimeters were placed on the top and the lateral side of the chest phantom so that the longitudinal direction of dosimeters was parallel to the orthogonal axis-to-slice plane for measurement of dose profiles in CT fluoroscopy. Measurement of fluoroscopic conditions was performed at 120 kVp and 80 kVp. Scatter radiation dose was evaluated by calculating the integrated dose determined by OSL dosimetry. The overall percent difference of the integrated doses between OSL dosimeters and ionization chamber was 5.92%. The ratio of the integrated dose of a 100-mm length area to its tails (−50 to −6 mm, 50 to 6 mm) was the lowest on the lateral side at 80 kVp and the highest on the top at 120 kVp. The IDRs for different measurement positions were larger at 120 kVp than at 80 kVp. Similarly, the IDRs for the tube voltage between the primary X-ray beam and scatter radiation was larger on the lateral side than on the top of the phantom. IDR evaluation suggested that the scatter radiation dose has a high dependence on the position and a low dependence on tube voltage relative to the primary X-ray beam for constant dose rate fluoroscopic conditions. These results provided quantitative evidence supporting the radiation protection methods used during CT fluoroscopy in previous studies.
Collapse
Affiliation(s)
- Hiroaki Hasegawa
- Department of Bioinformatics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan
- * E-mail:
| | - Masanori Sato
- Department of Radiological Sciences, Graduate School of Health Sciences, Komazawa University, Setagaya-ku, Tokyo, Japan
| | - Hiroshi Tanaka
- Department of Bioinformatics, Division of Medical Genomics, Medical Research Institute, Tokyo Medical and Dental University, Bunkyo-ku, Tokyo, Japan
| |
Collapse
|
16
|
Nascimento L, Vanhavere F, Silva E, Deene YD. A short-time fading study of Al2O3:C. Radiat Phys Chem Oxf Engl 1993 2015. [DOI: 10.1016/j.radphyschem.2014.06.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
17
|
Linear energy transfer dependence of Al2O3:C optically stimulated luminescence detectors exposed to therapeutic proton beams. RADIAT MEAS 2014. [DOI: 10.1016/j.radmeas.2014.03.026] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
18
|
Yukihara EG, McKeever SW, Akselrod MS. State of art: Optically stimulated luminescence dosimetry – Frontiers of future research. RADIAT MEAS 2014. [DOI: 10.1016/j.radmeas.2014.03.023] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
19
|
Seco J, Clasie B, Partridge M. Review on the characteristics of radiation detectors for dosimetry and imaging. Phys Med Biol 2014; 59:R303-47. [PMID: 25229250 DOI: 10.1088/0031-9155/59/20/r303] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
The enormous advances in the understanding of human anatomy, physiology and pathology in recent decades have led to ever-improving methods of disease prevention, diagnosis and treatment. Many of these achievements have been enabled, at least in part, by advances in ionizing radiation detectors. Radiology has been transformed by the implementation of multi-slice CT and digital x-ray imaging systems, with silver halide films now largely obsolete for many applications. Nuclear medicine has benefited from more sensitive, faster and higher-resolution detectors delivering ever-higher SPECT and PET image quality. PET/MR systems have been enabled by the development of gamma ray detectors that can operate in high magnetic fields. These huge advances in imaging have enabled equally impressive steps forward in radiotherapy delivery accuracy, with 4DCT, PET and MRI routinely used in treatment planning and online image guidance provided by cone-beam CT. The challenge of ensuring safe, accurate and precise delivery of highly complex radiation fields has also both driven and benefited from advances in radiation detectors. Detector systems have been developed for the measurement of electron, intensity-modulated and modulated arc x-ray, proton and ion beams, and around brachytherapy sources based on a very wide range of technologies. The types of measurement performed are equally wide, encompassing commissioning and quality assurance, reference dosimetry, in vivo dosimetry and personal and environmental monitoring. In this article, we briefly introduce the general physical characteristics and properties that are commonly used to describe the behaviour and performance of both discrete and imaging detectors. The physical principles of operation of calorimeters; ionization and charge detectors; semiconductor, luminescent, scintillating and chemical detectors; and radiochromic and radiographic films are then reviewed and their principle applications discussed. Finally, a general discussion of the application of detectors for x-ray nuclear medicine and ion beam imaging and dosimetry is presented.
Collapse
Affiliation(s)
- Joao Seco
- Department of Radiation Oncology, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts 02114, USA
| | | | | |
Collapse
|
20
|
Lehmann J, Dunn L, Lye JE, Kenny JW, Alves ADC, Cole A, Asena A, Kron T, Williams IM. Angular dependence of the response of the nanoDot OSLD system for measurements at depth in clinical megavoltage beams. Med Phys 2014; 41:061712. [DOI: 10.1118/1.4875698] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
21
|
Malthez ALM, Freitas MB, Yoshimura EM, Button VL. Application of optically stimulated luminescence technique to evaluate simultaneously accumulated and single doses with the same dosimeter. Radiat Phys Chem Oxf Engl 1993 2014. [DOI: 10.1016/j.radphyschem.2013.02.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
22
|
Nascimento L, Saldarriaga C, Vanhavere F, D'Agostino E, Defraene G, De Deene Y. Characterization of OSL Al2O3:C droplets for medical dosimetry. RADIAT MEAS 2013. [DOI: 10.1016/j.radmeas.2013.01.048] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
23
|
Omotayo AA, Cygler JE, Sawakuchi GO. The effect of different bleaching wavelengths on the sensitivity of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to 6 MV photon beams. Med Phys 2012; 39:5457-68. [PMID: 22957613 DOI: 10.1118/1.4742865] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To determine the effect of different bleaching wavelengths on the response of Al(2)O(3):C optically stimulated luminescence detectors (OSLDs) exposed to accumulated doses of 6 MV photon beams. METHODS In this study the authors used nanoDot OSLDs readout with a MicroStar reader. The authors first characterized the dose-response, fading, and OSL signal loss of OSLDs exposed to doses from 0.5 to 10 Gy. To determine the effect of different bleaching wavelengths on the OSLDs' response, the authors optically treated the OSLDs with 26 W fluorescent lamps in two modes: (i) directly under the lamps for 10, 120, and 600 min and (ii) with a long-pass filter for 55, 600, and 2000 min. Changes in the OSLDs' sensitivity were determined for an irradiation-readout-bleaching-readout cycle after irradiations with 1 and 10 Gy dose fractions. RESULTS The OSLDs presented supralinearity for doses of 2 Gy and above. The signal loss rates for sequential readouts were (0.287 ± 0.007)% per readout in the reader's strong-stimulation mode, and (0.019 ± 0.002)% and (0.035 ± 0.007)% per readout for doses of 0.2 and 10 Gy, respectively, in the reader's weak-stimulation mode. Fading half-life values ranged from (0.98 ± 0.14) min to (1.77 ± 0.24) min and fading showed dose dependence for the first 10-min interval. For 10 and 55 min bleaching using modes (i) and (ii), the OSL signal increased 14% for an accumulated dose of 7 Gy (1 Gy fractions). For OSLDs exposed to 10 Gy fractions, the OSL signal increased 30% and 25% for bleaching modes (i) and (ii) and accumulated dose of 70 Gy, respectively. For 120 and 600 min bleaching using modes (i) and (ii), the OSL signal increased 2.7% and 1.5% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 14% for bleaching mode (i) (120 min bleaching) and decreased 1.3% for bleaching mode (ii) (600 min bleaching) for an accumulated dose of 70 Gy. For 600 and 2000 min bleaching using modes (i) and (ii), the signal increased 2.3% and 1.8% for an accumulated dose of 7 Gy (1 Gy fractions), respectively. For 10 Gy fractions, the signal increased 10% for mode (i) (600 min bleaching) and decreased 2.5% for mode (ii) (2000 min bleaching) for an accumulated dose of 70 Gy. CONCLUSIONS The dose-response of nanoDot OSLDs read using the MicroStar reader presented supralinearity for doses of 2 Gy and above. The signal loss as a function of sequential readouts depended on dose. Fading also depended on dose for the first 10-min interval. For dose fractions of 1 and 10 Gy, OSLDs may be reused within 3% and 5% accuracies up to the maximum accumulated dose of 7 and 70 Gy investigated in this study, respectively. These accuracies were obtained after the OSLDs were bleached with a light source with wavelengths above about 495 nm. The authors also concluded that changes in sensitivity of OSLDs depended on bleaching time, accumulated dose, and wavelength spectrum of the bleaching source.
Collapse
Affiliation(s)
- Azeez A Omotayo
- Department of Physics, Carleton University, Ottawa, Ontario, Canada
| | | | | |
Collapse
|
24
|
Kerns JR, Kry SF, Sahoo N. Characteristics of optically stimulated luminescence dosimeters in the spread-out Bragg peak region of clinical proton beams. Med Phys 2012; 39:1854-63. [DOI: 10.1118/1.3693055] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
25
|
Sawakuchi GO, Yukihara EG. Analytical modeling of relative luminescence efficiency of Al2O3:C optically stimulated luminescence detectors exposed to high-energy heavy charged particles. Phys Med Biol 2011; 57:437-54. [DOI: 10.1088/0031-9155/57/2/437] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
26
|
Bartz J, Sykora G, Underwood T, Nichiporov D, Sawakuchi G, Akselrod M. Evaluation of aluminum oxide fluorescent and OSL detectors in proton radiotherapy beams. RADIAT MEAS 2011. [DOI: 10.1016/j.radmeas.2011.05.047] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
27
|
Ismail A, Pittet P, Lu G, Galvan J, Giraud J, Balosso J. In vivo dosimetric system based on Gallium Nitride radioluminescence. RADIAT MEAS 2011. [DOI: 10.1016/j.radmeas.2011.02.011] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
28
|
Al-Senan RM, Hatab MR. Characteristics of an OSLD in the diagnostic energy range. Med Phys 2011; 38:4396-405. [PMID: 21859040 DOI: 10.1118/1.3602456] [Citation(s) in RCA: 102] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. METHODS NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energy dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. RESULTS Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R2 > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 degrees in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). CONCLUSIONS OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.
Collapse
Affiliation(s)
- Rani M Al-Senan
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229, USA.
| | | |
Collapse
|
29
|
Kerns JR, Kry SF, Sahoo N, Followill DS, Ibbott GS. Angular dependence of the nanoDot OSL dosimeter. Med Phys 2011; 38:3955-62. [PMID: 21858992 DOI: 10.1118/1.3596533] [Citation(s) in RCA: 77] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Optically stimulated luminescent detectors (OSLDs) are quickly gaining popularity as passive dosimeters, with applications in medicine for linac output calibration verification, brachytherapy source verification, treatment plan quality assurance, and clinical dose measurements. With such wide applications, these dosimeters must be characterized for numerous factors affecting their response. The most abundant commercial OSLD is the InLight/OSL system from Landauer, Inc. The purpose of this study was to examine the angular dependence of the nanoDot dosimeter, which is part of the InLight system. METHODS Relative dosimeter response data were taken at several angles in 6 and 18 MV photon beams, as well as a clinical proton beam. These measurements were done within a phantom at a depth beyond the build-up region. To verify the observed angular dependence, additional measurements were conducted as well as Monte Carlo simulations in MCNPX. RESULTS When irradiated with the incident photon beams parallel to the plane of the dosimeter, the nanoDot response was 4% lower at 6 MV and 3% lower at 18 MV than the response when irradiated with the incident beam normal to the plane of the dosimeter. Monte Carlo simulations at 6 MV showed similar results to the experimental values. Examination of the results in Monte Carlo suggests the cause as partial volume irradiation. In a clinical proton beam, no angular dependence was found. CONCLUSIONS A nontrivial angular response of this OSLD was observed in photon beams. This factor may need to be accounted for when evaluating doses from photon beams incident from a variety of directions.
Collapse
Affiliation(s)
- James R Kerns
- Department of Radiation Physics, UT MD Anderson Cancer Center, 1515 Holcombe Boulevard, Houston, Texas 77030, USA.
| | | | | | | | | |
Collapse
|
30
|
Mrčela I, Bokulić T, Izewska J, Budanec M, Fröbe A, Kusić Z. Optically stimulated luminescencein vivodosimetry for radiotherapy: physical characterization and clinical measurements in60Co beams. Phys Med Biol 2011; 56:6065-82. [DOI: 10.1088/0031-9155/56/18/018] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|