• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4629796)   Today's Articles (167)   Subscriber (49731)
For: Yoshitomi H, Nishino S, Tanimura Y, Takahashi M. A study of a calibration technique for a newly developed thyroid monitor and its uncertainties due to body size for radioiodine measurements. RADIAT MEAS 2020. [DOI: 10.1016/j.radmeas.2020.106279] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Number Cited by Other Article(s)
1
Narita M, Tani K, Kunishima N, Kim E, Kurihara O. Uncertainties associated with direct thyroid measurements using an NaI(Tl) survey meter: the effect of anatomical differences among individuals. RADIATION PROTECTION DOSIMETRY 2023;199:1802-1806. [PMID: 37819325 DOI: 10.1093/rpd/ncac265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 10/12/2022] [Accepted: 11/19/2022] [Indexed: 10/13/2023]
2
Liu G, Li Y, Zhang H, Zhang X, Liu YY, Wu XQ, Niu LM, Zhang R. Thyroid dose assessments due to inhalation of 131I for nuclear medicine workers. Front Public Health 2022;10:1027782. [PMID: 36544792 PMCID: PMC9760871 DOI: 10.3389/fpubh.2022.1027782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 11/07/2022] [Indexed: 12/09/2022]  Open
3
Measurement of 131I activity in thyroid using a dual-layer detector. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2022.106743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
4
Karami M, Miri-Hakimabad H, Hoseinian-Azghadi E, Mohammadi N. A method for assessing subject-specific counting efficiency of whole-body monitoring systems for radioiodine measurements. RADIAT MEAS 2020. [DOI: 10.1016/j.radmeas.2020.106430] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
5
Tanimura Y, Yoshitomi H, Nishino S, Takahashi M. Background correction method for portable thyroid dose monitor using gamma-ray spectrometer developed at JAEA in high dose rate environment. RADIAT MEAS 2020. [DOI: 10.1016/j.radmeas.2020.106389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA