Robotic image-guided stereotactic radiotherapy, for isolated recurrent primary, lymph node or metastatic prostate cancer.
Int J Radiat Oncol Biol Phys 2011;
82:889-97. [PMID:
21277113 DOI:
10.1016/j.ijrobp.2010.11.031]
[Citation(s) in RCA: 192] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2010] [Revised: 11/20/2010] [Accepted: 11/30/2010] [Indexed: 12/11/2022]
Abstract
PURPOSE
To evaluate the outcome of robotic CyberKnife (Accuray, Sunnyvale, CA)-based stereotactic radiotherapy (CBK-SRT) for isolated recurrent primary, lymph node, or metastatic prostate cancer.
METHODS AND MATERIALS
Between May 2007 and December 2009, 34 consecutive patients/38 lesions were treated (15 patients reirradiated for local recurrence [P], 4 patients reirradiated for anastomosis recurrence [A], 16 patients treated for single lymph node recurrence [LN], and 3 patients treated for single metastasis [M]). In all but 4 patients, [(11)C]choline positron emission tomography/computed tomography was performed. CBK-SRT consisted of reirradiation and first radiotherapy in 27 and 11 lesions, respectively. The median CBK-SRT dose was 30 Gy in 4.5 fractions (P, 30 Gy in 5 fractions; A, 30 Gy in 5 fractions; LN, 33 Gy in 3 fractions; and M, 36 Gy in 3 fractions). In 18 patients (21 lesions) androgen deprivation was added to CBK-SRT (median duration, 16.6 months).
RESULTS
The median follow-up was 16.9 months. Acute toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event). Late toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event and 1 Grade 2 event). Biochemical response was observed in 32 of 38 evaluable lesions. Prostate-specific antigen stabilization was seen for 4 lesions, and in 2 cases prostate-specific antigen progression was reported. The 30-month progression-free survival rate was 42.6%. Disease progression was observed for 14 lesions (5, 2, 5, and 2 in Groups P, A, LN, and M respectively). In only 3 cases, in-field progression was seen. At the time of analysis (May 2010), 19 patients are alive with no evidence of disease and 15 are alive with disease.
CONCLUSIONS
CyberKnife-based stereotactic radiotherapy is a feasible approach for isolated recurrent primary, lymph node, or metastatic prostate cancer, offering excellent in-field tumor control and a low toxicity profile. Further investigation is warranted to identify the patients who benefit most from this treatment modality. The optimal combination with androgen deprivation should also be defined.