Ohira S, Mochizuki J, Niwa T, Endo K, Minamitani M, Yamashita H, Katano A, Imae T, Nishio T, Koizumi M, Nakagawa K. Variation in Hounsfield unit calculated using dual-energy computed tomography: comparison of dual-layer, dual-source, and fast kilovoltage switching technique. Radiol Phys Technol 2024; 17:458-466. [PMID: 38700638 PMCID: PMC11128400 DOI: 10.1007/s12194-024-00802-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Revised: 04/09/2024] [Accepted: 04/10/2024] [Indexed: 05/27/2024]
Abstract
The purpose of the study is to investigate the variation in Hounsfield unit (HU) values calculated using dual-energy computed tomography (DECT) scanners. A tissue characterization phantom inserting 16 reference materials were scanned three times using DECT scanners [dual-layer CT (DLCT), dual-source CT (DSCT), and fast kilovoltage switching CT (FKSCT)] changing scanning conditions. The single-energy CT images (120 or 140 kVp), and virtual monochromatic images at 70 keV (VMI70) and 140 keV (VMI140) were reconstructed, and the HU values of each reference material were measured. The difference in HU values was larger when the phantom was scanned using the half dose with wrapping with rubber (strong beam-hardening effect) compared with the full dose without the rubber (reference condition), and the difference was larger as the electron density increased. For SECT, the difference in HU values against the reference condition measured by the DSCT (3.2 ± 5.0 HU) was significantly smaller (p < 0.05) than that using DLCT with 120 kVp (22.4 ± 23.8 HU), DLCT with 140 kVp (11.4 ± 12.8 HU), and FKSCT (13.4 ± 14.3 HU). The respective difference in HU values in the VMI70 and VMI140 measured using the DSCT (10.8 ± 17.1 and 3.5 ± 4.1 HU) and FKSCT (11.5 ± 21.8 and 5.5 ± 10.4 HU) were significantly smaller than those measured using the DLCT120 (23.1 ± 27.5 and 12.4 ± 9.4 HU) and DLCT140 (22.3 ± 28.6 and 13.1 ± 11.4 HU). The HU values and the susceptibility to beam-hardening effects varied widely depending on the DECT scanners.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Comprehensive Radiation Oncology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
| | - Junji Mochizuki
- Department of Radiology, Minamino Cardiovascular Hospital, Tokyo, Japan
| | - Tatsunori Niwa
- Department of Radiology, Sakakibara Heart Institute, Tokyo, Japan
| | - Kazuyuki Endo
- Department of Radiologic Technology, Tokai University Hachioji Hospital, Tokyo, Japan
| | - Masanari Minamitani
- Department of Comprehensive Radiation Oncology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Hideomi Yamashita
- Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan
| | - Atsuto Katano
- Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan
| | - Toshikazu Imae
- Department of Radiology, The University of Tokyo Hospital, Tokyo, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Keiichi Nakagawa
- Department of Comprehensive Radiation Oncology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| |
Collapse
|
2
|
Ohira S, Ikawa T, Kanayama N, Minamitani M, Kihara S, Inui S, Ueda Y, Miyazaki M, Yamashita H, Nishio T, Koizumi M, Nakagawa K, Konishi K. Dual-energy computed tomography-based iodine concentration as a predictor of histopathological response to preoperative chemoradiotherapy for pancreatic cancer. JOURNAL OF RADIATION RESEARCH 2023; 64:940-947. [PMID: 37839063 PMCID: PMC10665298 DOI: 10.1093/jrr/rrad076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 09/08/2023] [Indexed: 10/17/2023]
Abstract
To explore predictors of the histopathological response to preoperative chemoradiotherapy (CRT) in patients with pancreatic cancer (PC) using dual-energy computed tomography-reconstructed images. This retrospective study divided 40 patients who had undergone preoperative CRT (50-60 Gy in 25 fractions) followed by surgical resection into two groups: the response group (Grades II, III and IV, evaluated from surgical specimens) and the nonresponse group (Grades Ia and Ib). The computed tomography number [in Hounsfield units (HUs)] and iodine concentration (IC) were measured at the locations of the aorta, PC and pancreatic parenchyma (PP) in the contrast-enhanced 4D dual-energy computed tomography images. Logistic regression analysis was performed to identify predictors of histopathological response. Univariate analysis did not reveal a significant relation between any parameter and patient characteristics or dosimetric parameters of the treatment plan. The HU and IC values in PP and the differences in HU and IC between the PP and PC (ΔHU and ΔIC, respectively) were significant predictors for distinguishing the response (n = 24) and nonresponse (n = 16) groups (P < 0.05). The IC in PP and ΔIC had a higher area under curve values [0.797 (95% confidence interval, 0.659-0.935) and 0.789 (0.650-0.928), respectively] than HU in PP and ΔHU [0.734 (0.580-0.889) and 0.721 (0.562-0.881), respectively]. The IC value could potentially be used for predicting the histopathological response in patients who have undergone preoperative CRT.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita, Osaka, 565-0871, Japan
- Department of Comprehensive Radiation Oncology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Toshiki Ikawa
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
| | - Masanari Minamitani
- Department of Comprehensive Radiation Oncology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Sayaka Kihara
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
| | - Shoki Inui
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
| | - Hideomi Yamashita
- Department of Radiology, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Keiichi Nakagawa
- Department of Comprehensive Radiation Oncology, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan
| | - Koji Konishi
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuo-ku, Osaka 537-8567, Japan
| |
Collapse
|
3
|
Yang M, Wohlfahrt P, Shen C, Bouchard H. Dual- and multi-energy CT for particle stopping-power estimation: current state, challenges and potential. Phys Med Biol 2023; 68. [PMID: 36595276 DOI: 10.1088/1361-6560/acabfa] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Range uncertainty has been a key factor preventing particle radiotherapy from reaching its full physical potential. One of the main contributing sources is the uncertainty in estimating particle stopping power (ρs) within patients. Currently, theρsdistribution in a patient is derived from a single-energy CT (SECT) scan acquired for treatment planning by converting CT number expressed in Hounsfield units (HU) of each voxel toρsusing a Hounsfield look-up table (HLUT), also known as the CT calibration curve. HU andρsshare a linear relationship with electron density but differ in their additional dependence on elemental composition through different physical properties, i.e. effective atomic number and mean excitation energy, respectively. Because of that, the HLUT approach is particularly sensitive to differences in elemental composition between real human tissues and tissue surrogates as well as tissue variations within and among individual patients. The use of dual-energy CT (DECT) forρsprediction has been shown to be effective in reducing the uncertainty inρsestimation compared to SECT. The acquisition of CT data over different x-ray spectra yields additional information on the material elemental composition. Recently, multi-energy CT (MECT) has been explored to deduct material-specific information with higher dimensionality, which has the potential to further improve the accuracy ofρsestimation. Even though various DECT and MECT methods have been proposed and evaluated over the years, these approaches are still only scarcely implemented in routine clinical practice. In this topical review, we aim at accelerating this translation process by providing: (1) a comprehensive review of the existing DECT/MECT methods forρsestimation with their respective strengths and weaknesses; (2) a general review of uncertainties associated with DECT/MECT methods; (3) a general review of different aspects related to clinical implementation of DECT/MECT methods; (4) other potential advanced DECT/MECT applications beyondρsestimation.
Collapse
Affiliation(s)
- Ming Yang
- The University of Texas MD Anderson Cancer Center, Department of Radiation Physics, 1515 Holcombe Blvd Houston, TX 77030, United States of America
| | - Patrick Wohlfahrt
- Massachusetts General Hospital and Harvard Medical School, Department of Radiation Oncology, Boston, MA 02115, United States of America
| | - Chenyang Shen
- University of Texas Southwestern Medical Center, Department of Radiation Oncology, 2280 Inwood Rd Dallas, TX 75235, United States of America
| | - Hugo Bouchard
- Département de physique, Université de Montréal, Complexe des sciences, 1375 Avenue Thérèse-Lavoie-Roux, Montréal, Québec H2V0B3, Canada.,Centre de recherche du Centre hospitalier de l'Université de Montréal, 900 Rue Saint-Denis, Montréal, Québec, H2X 0A9, Canada.,Département de radio-oncologie, Centre hospitalier de l'Université de Montréal, 1051 Rue Sanguinet, Montréal, Québec H2X 3E4, Canada
| |
Collapse
|
4
|
Dose reduction of hippocampus using HyperArc planning in postoperative radiotherapy for primary brain tumors. Med Dosim 2023; 48:67-72. [PMID: 36653285 DOI: 10.1016/j.meddos.2022.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Revised: 12/05/2022] [Accepted: 12/06/2022] [Indexed: 01/18/2023]
Abstract
To compare dosimetric parameters for the hippocampus, organs at risk (OARs), and targets of volumetric modulated arc therapy (VMAT), noncoplanar VMAT (NC-VMAT), and HyperArc (HA) plans in patients undergoing postoperative radiotherapy for primary brain tumors. For 20 patients, HA plans were generated to deliver 40.05 to 60 Gy for the planning target volume (PTV). In addition, doses for the hippocampus and OARs were minimized. The VMAT and NC-VMAT plans were retrospectively generated using the same optimization parameters as those in the HA plans. For the hippocampus, the equivalent dose to be administered in 2 Gy fractions (EQD2) was calculated assuming α/β = 2. Dosimetric parameters for the PTV, hippocampus, and OARs in the VMAT, NC-VMAT, and HA plans were compared. For PTV, the HA plans provided significantly lower Dmax and D1% than the VMAT and NC-VMAT plans (p < 0.05), whereas the D99% and Dmin were significantly higher (p < 0.05). For the contralateral hippocampus, the dosimetric parameters in the HA plans (8.1 ± 9.6, 6.5 ± 7.2, 5.6 ± 5.8, and 4.8 ± 4.7 Gy for D20%, D40%, D60% and D80%, respectively) were significantly smaller (p < 0.05) than those in the VMAT and NC-VMAT plans. Except for the optic chiasm, the Dmax in the HA plans (brainstem, lens, optic nerves, and retinas) was the smallest (p < 0.05). In addition, the doses in the HA plans for the brain and skin were the smallest (p < 0.05) among the 3 plans. HA planning, instead of coplanar and noncoplanar VMAT, significantly reduces the dosage to which the contralateral hippocampus as well as other OARs are exposed without compromising on target coverage.
Collapse
|
5
|
Ohira S, Koike Y, Akino Y, Kanayama N, Wada K, Ueda Y, Masaoka A, Washio H, Miyazaki M, Koizumi M, Ogawa K, Teshima T. Improvement of image quality for pancreatic cancer using deep learning-generated virtual monochromatic images: Comparison with single-energy computed tomography. Phys Med 2021; 85:8-14. [PMID: 33940528 DOI: 10.1016/j.ejmp.2021.03.035] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 02/25/2021] [Accepted: 03/30/2021] [Indexed: 01/15/2023] Open
Abstract
PURPOSE To construct a deep convolutional neural network that generates virtual monochromatic images (VMIs) from single-energy computed tomography (SECT) images for improved pancreatic cancer imaging quality. MATERIALS AND METHODS Fifty patients with pancreatic cancer underwent a dual-energy CT simulation and VMIs at 77 and 60 keV were reconstructed. A 2D deep densely connected convolutional neural network was modeled to learn the relationship between the VMIs at 77 (input) and 60 keV (ground-truth). Subsequently, VMIs were generated for 20 patients from SECT images using the trained deep learning model. RESULTS The contrast-to-noise ratio was significantly improved (p < 0.001) in the generated VMIs (4.1 ± 1.8) compared to the SECT images (2.8 ± 1.1). The mean overall image quality (4.1 ± 0.6) and tumor enhancement (3.6 ± 0.6) in the generated VMIs assessed on a five-point scale were significantly higher (p < 0.001) than that in the SECT images (3.2 ± 0.4 and 2.8 ± 0.4 for overall image quality and tumor enhancement, respectively). CONCLUSIONS The quality of the SECT image was significantly improved both objectively and subjectively using the proposed deep learning model for pancreatic tumors in radiotherapy.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
| | - Yuhei Koike
- Department of Radiology, Kansai Medical University, Osaka, Japan
| | - Yuichi Akino
- Division of Medical Physics, Oncology Center, Osaka University Hospital, Suita, Japan
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Kentaro Wada
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Akira Masaoka
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Hayate Washio
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
6
|
A Third-Generation Adaptive Statistical Iterative Reconstruction for Contrast-Enhanced 4-Dimensional Dual-Energy Computed Tomography for Pancreatic Cancer. J Comput Assist Tomogr 2021; 45:18-23. [PMID: 31738200 DOI: 10.1097/rct.0000000000000942] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVES The objective of this study was to assess the objective and subjective qualities of the contrast-enhanced 4-dimensional dual-energy computed tomography using adaptive statistical iterative reconstruction (ASiR) and ASiR-V. METHODS The virtual monochromatic images at 60 keV were reconstructed using filtered back projection, ASiR, and ASiR-V (10%-100%) for 14 patients with pancreatic cancer. The contrast-to-noise ratio (CNR) was calculated, and the subjective measurements were compared based on a 5-point score scale. RESULTS The ASiR-V yielded a significantly higher CNR than ASiR (P < 0.05). The subjective image quality (peak) was significantly improved (P < 0.01) with ASiR (50%) (3.8, 3.5, and 4.0; overall image quality, tumor delineation, and noise, respectively) and with ASiR-V (50%) (3.9, 3.5, and 4.2, respectively) compared with the filtered back projection (3.2, 3.2, and 3.0, respectively). CONCLUSIONS The ASiR-V yielded higher CNR than ASiR and provided the highest subjective scores regarding the overall image quality.
Collapse
|
7
|
Ohira S, Kanayama N, Wada K, Ikawa T, Hirata T, Kishi N, Karino T, Washio H, Ueda Y, Miyazaki M, Koizumi M, Teshima T. Improvement of image quality and assessment of respiratory motion for hepatocellular carcinoma with portal vein tumor thrombosis using contrast-enhanced four-dimensional dual-energy computed tomography. PLoS One 2021; 16:e0244079. [PMID: 33481820 PMCID: PMC7822294 DOI: 10.1371/journal.pone.0244079] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2019] [Accepted: 12/02/2020] [Indexed: 11/18/2022] Open
Abstract
To assess the objective and subjective image quality, and respiratory motion of hepatocellular carcinoma with portal vein tumor thrombosis (PVTT) using the contrast-enhanced four-dimensional dual-energy computed tomography (CE-4D-DECT). For twelve patients, the virtual monochromatic image (VMI) derived from the CE-4D-DECT with the highest contrast to noise ratio (CNR) was determined as the optimal VMI (O-VMI). To assess the objective and subjective image quality, the CNR and five-point score of the O-VMI were compared to those of the standard VMI at 77 keV (S-VMI). The respiratory motion of the PVTT and diaphragm was measured based on the exhale and inhale phase images. The VMI at 60 keV yielded the highest CNR (4.8 ± 1.4) which was significantly higher (p = 0.02) than that in the S-VMI (3.8 ± 1.2). The overall image quality (4.0 ± 0.6 vs 3.1 ± 0.5) and tumor conspicuity (3.8 ± 0.8 vs 2.8 ± 0.6) of the O-VMI determined by three radiation oncologists was significantly higher (p < 0.01) than that of the S-VMI. The diaphragm motion in the L-R (3.3 ± 2.5 vs 1.2 ± 1.1 mm), A-P (6.7 ± 4.0 vs 1.6 ± 1.3mm) and 3D (8.8 ± 3.5 vs 13.1 ± 4.9 mm) directions were significantly larger (p < 0.05) compared to the tumor motion. The improvement of objective and subjective image quality was achieved in the O-VMI. Because the respiratory motion of the diaphragm was larger than that of the PVTT, we need to be pay attention for localizing target in radiotherapy.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
- * E-mail:
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Kentaro Wada
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Toshiki Ikawa
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Takero Hirata
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Noriko Kishi
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
- Department of Radiation Oncology and Image-Applied Therapy, Graduate School of Medicine, Kyoto University, Kyoto, Japan
| | - Tsukasa Karino
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Hayate Washio
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
8
|
Wohlfahrt P, Richter C. Status and innovations in pre-treatment CT imaging for proton therapy. Br J Radiol 2020; 93:20190590. [PMID: 31642709 PMCID: PMC7066941 DOI: 10.1259/bjr.20190590] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 10/04/2019] [Accepted: 10/21/2019] [Indexed: 12/19/2022] Open
Abstract
Pre-treatment CT imaging is a topic of growing importance in particle therapy. Improvements in the accuracy of stopping-power prediction are demanded to allow for a dose conformality that is not inferior to state-of-the-art image-guided photon therapy. Although range uncertainty has been kept practically constant over the last decades, recent technological and methodological developments, like the clinical application of dual-energy CT, have been introduced or arise at least on the horizon to improve the accuracy and precision of range prediction. This review gives an overview of the current status, summarizes the innovations in dual-energy CT and its potential impact on the field as well as potential alternative technologies for stopping-power prediction.
Collapse
Affiliation(s)
- Patrick Wohlfahrt
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA
| | | |
Collapse
|
9
|
Karino T, Ohira S, Kanayama N, Wada K, Ikawa T, Nitta Y, Washio H, Miyazaki M, Teshima T. Determination of optimal virtual monochromatic energy level for target delineation of brain metastases in radiosurgery using dual-energy CT. Br J Radiol 2020; 93:20180850. [PMID: 31825643 DOI: 10.1259/bjr.20180850] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
OBJECTIVE Determination of the optimal energy level of virtual monochromatic image (VMI) for brain metastases in contrast-enhanced dual-energy CT (DECT) for radiosurgery and assessment of the subjective and objective image quality of VMI at the optimal energy level. METHODS 20 patients (total of 42 metastases) underwent contrast-enhanced DECT. Spectral image analysis of VMIs at energy levels ranging from 40 to 140 keV in 1 keV increments was performed to determine the optimal VMI (VMIopt) as the one corresponding to the highest contrast-to-noise ratio (CNR) between brain parenchyma and the metastases. The objective and subjective values of VMIopt were compared to those of the VMI with 120 kVp equivalent, defined as reference VMI (VMIref, 77 keV). The objective measurement parameters included mean HU value and SD of tumor and brain parenchyma, absolute lesion contrast (LC), and CNR. The subjective measurements included five-point scale assessment of "overall image quality" and "tumor delineation" by three radiation oncologists. RESULTS The VMI at 63 keV was defined as VMIopt. The LC and CNR of VMIopt were significantly (p < 0.01) higher than those of VMIref (LC: 37.4 HU vs 24.7 HU; CNR: 1.1 vs 0.8, respectively). Subjective analysis rated VMIopt significantly (p < 0.01) superior to VMIref with respect to the overall image quality (3.2 vs 2.9, respectively) and tumor delineation (3.5 vs 2.9, respectively). CONCLUSION The VMI at 63 keV derived from contrast-enhanced DECT yielded the highest CNR and improved the objective and subjective image quality for radiosurgery, compared to VMIref. ADVANCES IN KNOWLEDGE This paper investigated for the first time the optimal energy level of VMI in DECT for brain metastases. The findings will lead to improvement in tumor visibility with optimal VMI and consequently supplement accuracy delineation of brain metastases.
Collapse
Affiliation(s)
- Tsukasa Karino
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.,Department of Medical Physics and Engineering, Osaka University Graduate of Medicine, Osaka, Japan
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Kentaro Wada
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Toshiki Ikawa
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Yuya Nitta
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Hayate Washio
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.,Department of Radiology, Hyogo College of Medicine, Hyogo, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
10
|
Ohira S, Kanayama N, Toratani M, Ueda Y, Koike Y, Karino T, Shunsuke O, Miyazaki M, Koizumi M, Teshima T. Stereotactic body radiation therapy planning for liver tumors using functional images from dual-energy computed tomography. Radiother Oncol 2020; 145:56-62. [PMID: 31923710 DOI: 10.1016/j.radonc.2019.12.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 12/05/2019] [Accepted: 12/07/2019] [Indexed: 12/12/2022]
Abstract
PURPOSE This study aimed to generate a functional image of the liver using dual-energy computed tomography (DECT) and a functional-image-based stereotactic body radiation therapy plan to minimize the dose to the volume of the functional liver (Vfl). MATERIAL AND METHODS A normalized iodine density (NID) map was generated for fifteen patients with liver tumors. The volume of liver with an NID < 0.46 was defined as Vfl, and the ratio between Vfl and the total volume of the liver (FLR) was calculated. The relationship between the FLR and Fibrosis-4 (FIB-4) was assessed. For patients with 15% < FLR < 85%, functional volumetric modulated-arc therapy plans (F-VMAT) were retrospectively generated to preserve Vfl, and compared to the clinical plans (C-VMAT). RESULTS FLR showed a significantly strong correlation with FIB-4 (r = -0.71, p < 0.01). For ten generated F-VMAT plans, the dosimetric parameters of D99%, D50%, D1% and the conformity index were comparable to those of the C-VMAT (p > 0.05). For Vfl, F-VMAT plans achieved lower V5Gy (122.4 ± 31.7 vs 181.1 ± 57.3 cc), V10Gy (44.4 ± 22.2 vs 98.2 ± 33.3 cc), V15Gy (22.6 ± 20.3 vs 49.8 ± 33.7 cc), V20Gy (11.6 ± 14.1 vs 24.9 ± 25.1 cc), and Dmean (3.9 ± 2.3 vs 5.8 ± 3.0 Gy) values than the C-VMAT plans (p < 0.01). CONCLUSIONS The functional image derived from DECT was successfully used, allowing for a reduction in the dose to the Vfl without compromising target coverage.
Collapse
Affiliation(s)
- Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
| | - Naoyuki Kanayama
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan
| | - Masayasu Toratani
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan
| | - Yuhei Koike
- Department of Radiation Oncology, Osaka University Graduate School of Medicine, Suita, Japan
| | - Tsukasa Karino
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan
| | - Ono Shunsuke
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan; Department of Radiology, Hyogo College of Medicine, Hyogo, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, Japan
| |
Collapse
|
11
|
Koike Y, Ohira S, Akino Y, Sagawa T, Yagi M, Ueda Y, Miyazaki M, Sumida I, Teshima T, Ogawa K. Deep learning‐based virtual noncontrast CT for volumetric modulated arc therapy planning: Comparison with a dual‐energy CT‐based approach. Med Phys 2019; 47:371-379. [DOI: 10.1002/mp.13925] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 11/11/2019] [Accepted: 11/11/2019] [Indexed: 12/12/2022] Open
Affiliation(s)
- Yuhei Koike
- Department of Radiation Oncology Osaka University Graduate School of Medicine Suita 565‐0871Japan
| | - Shingo Ohira
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Yuichi Akino
- Oncology center Osaka University Hospital Suita 565‐0871Japan
| | - Tomohiro Sagawa
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Masashi Yagi
- Department of Carbon Ion Radiotherapy Osaka University Graduate School of Medicine Suita 565‐0871Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Iori Sumida
- Department of Radiation Oncology Osaka University Graduate School of Medicine Suita 565‐0871Japan
| | - Teruki Teshima
- Department of Radiation Oncology Osaka International Cancer Institute Osaka 541‐8567Japan
| | - Kazuhiko Ogawa
- Department of Radiation Oncology Osaka University Graduate School of Medicine Suita 565‐0871Japan
| |
Collapse
|
12
|
Dual-energy computed tomography for evaluation of breast cancer: value of virtual monoenergetic images reconstructed with a noise-reduced monoenergetic reconstruction algorithm. Jpn J Radiol 2019; 38:154-164. [PMID: 31686294 DOI: 10.1007/s11604-019-00897-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Accepted: 10/24/2019] [Indexed: 01/11/2023]
Abstract
PURPOSE To evaluate the image quality and lesion visibility of virtual monoenergetic images (VMIs) reconstructed using a new monoenergetic reconstruction algorithm (nMERA) for evaluation of breast cancer. MATERIALS AND METHODS Forty-two patients with 46 breast cancers who underwent 4-phasic breast contrast-enhanced computed tomography (CT) using dual-energy CT (DECT) were enrolled. We selected the peak enhancement phase of the lesion in each patient. The selected phase images were generated by 120-kVp-equivalent linear blended (M120) and monoenergetic reconstructions from 40 to 80 keV using the standard reconstruction algorithm (sMERA: 40, 50, 60, 70, 80) and nMERA (40 +, 50 +, 60 +, 70 +, 80 +). The contrast-to-noise ratio (CNR) was calculated and objectively analyzed. Two independent readers subjectively scored tumor visibility and image quality each on a 5-point scale. RESULTS The CNR at 40 + and tumor visibility scores at 40 + and 50 + were significantly higher than those on M120. The CNR at 50 + was not significantly different from that on M120. However, the overall image quality score at 40 + was significantly lower than that at 50 + and on M120 (40 + vs M120, P < 0.0001 and 40 + vs 50 +, P = 0.0001). CONCLUSIONS VMI reconstructed with nMERA at 50 keV is preferable for evaluation of patients with breast cancer.
Collapse
|
13
|
Sagawa T, Ohira S, Ueda Y, Akino Y, Mizuno H, Matsumoto M, Miyazaki M, Koizumi M, Teshima T. Dosimetric effect of rotational setup errors in stereotactic radiosurgery with HyperArc for single and multiple brain metastases. J Appl Clin Med Phys 2019; 20:84-91. [PMID: 31507075 PMCID: PMC6806481 DOI: 10.1002/acm2.12716] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 07/31/2019] [Accepted: 08/19/2019] [Indexed: 12/25/2022] Open
Abstract
Purpose In stereotactic radiosurgery (SRS) with single‐isocentric treatments for brain metastases, rotational setup errors may cause considerable dosimetric effects. We assessed the dosimetric effects on HyperArc plans for single and multiple metastases. Methods For 29 patients (1–8 brain metastases), HyperArc plans with a prescription dose of 20–24 Gy for a dose that covers 95% (D95%) of the planning target volume (PTV) were retrospectively generated (Ref‐plan). Subsequently, the computed tomography (CT) used for the Ref‐plan and cone‐beam CT acquired during treatments (Rot‐CT) were registered. The HyperArc plans involving rotational setup errors (Rot‐plan) were generated by re‐calculating doses based on the Rot‐CT. The dosimetric parameters between the two plans were compared. Results The dosimetric parameters [D99%, D95%, D1%, homogeneity index, and conformity index (CI)] for the single‐metastasis cases were comparable (P > 0.05), whereas the D95% for each PTV of the Rot‐plan decreased 10.8% on average, and the CI of the Rot‐plan was also significantly lower than that of the Ref‐plan (Ref‐plan vs Rot‐plan, 0.93 ± 0.02 vs 0.75 ± 0.14, P < 0.01) for the multiple‐metastases cases. In addition, for the multiple‐metastases cases, the Rot‐plan resulted in significantly higher V10Gy (P = 0.01), V12Gy (P = 0.02), V14Gy (P = 0.02), and V16Gy (P < 0.01) than those in the Ref‐plan. Conclusion The rotational setup errors for multiple brain metastases cases caused non‐negligible underdosage for PTV and significant increases of V10Gy to V16Gy in SRS with HyperArc.
Collapse
Affiliation(s)
- Tomohiro Sagawa
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan.,Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Yuichi Akino
- Division of Medical Physics, Oncology Center, Osaka University Hospital, Suita, Japan
| | - Hirokazu Mizuno
- Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Japan
| | - Masao Matsumoto
- Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| | - Masahiko Koizumi
- Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan
| |
Collapse
|
14
|
Ohira S, Komiyama R, Karino T, Washio H, Ueda Y, Miyazaki M, Koizumi M, Teshima T. Volumetric modulated arc therapy planning based on virtual monochromatic images: Effect of inaccurate CT numbers on dose distributions. Phys Med 2019; 60:83-90. [DOI: 10.1016/j.ejmp.2019.03.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 03/15/2019] [Accepted: 03/20/2019] [Indexed: 01/15/2023] Open
|
15
|
Ohira S, Washio H, Yagi M, Karino T, Nakamura K, Ueda Y, Miyazaki M, Koizumi M, Teshima T. Estimation of electron density, effective atomic number and stopping power ratio using dual-layer computed tomography for radiotherapy treatment planning. Phys Med 2018; 56:34-40. [DOI: 10.1016/j.ejmp.2018.11.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 09/25/2018] [Accepted: 11/15/2018] [Indexed: 01/17/2023] Open
|