1
|
Albers J, Pacilé S, Markus MA, Wiart M, Vande Velde G, Tromba G, Dullin C. X-ray-Based 3D Virtual Histology-Adding the Next Dimension to Histological Analysis. Mol Imaging Biol 2019; 20:732-741. [PMID: 29968183 DOI: 10.1007/s11307-018-1246-3] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Histology and immunohistochemistry of thin tissue sections have been the standard diagnostic procedure in many diseases for decades. This method is highly specific for particular tissue regions or cells, but mechanical sectioning of the specimens is required, which destroys the sample in the process and can lead to non-uniform tissue deformations. In addition, regions of interest cannot be located beforehand and the analysis is intrinsically two-dimensional. Micro X-ray computed tomography (μCT) on the other hand can provide 3D images at high resolution and allows for quantification of tissue structures, as well as the localization of small regions of interest. These advantages advocate the use of μCT for virtual histology tool with or without subsequent classical histology. This review summarizes the most recent examples of virtual histology and provides currently known possibilities of improving contrast and resolution of μCT. Following a background in μCT imaging, ex vivo staining procedures for contrast enhancement are presented as well as label-free virtual histology approaches and the technologies, which could rapidly advance it, such as phase-contrast CT. Novel approaches such as zoom tomography and nanoparticulate contrast agents will also be considered. The current evidence suggests that virtual histology may present a valuable addition to the workflow of histological analysis, potentially reducing the workload in pathology, refining tissue classification, and supporting the detection of small malignancies.
Collapse
Affiliation(s)
- J Albers
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany
| | - S Pacilé
- Department of Engineering and Architecture, University of Trieste, Trieste, Italy.,Elettra Sincrotrone Trieste, Trieste, Italy
| | - M A Markus
- Translational Molecular Imaging, Max-Planck-Institute for Experimental Medicine, Göttingen, Germany
| | - M Wiart
- Univ Lyon, CarMeN Laboratory, INSERM, INRA, INSA Lyon, Université Claude Bernard Lyon 1, 69500, Bron, France
| | - G Vande Velde
- Department of Imaging and Pathology, Faculty of Medicine, KU Leuven-University of Leuven, Leuven, Belgium
| | - G Tromba
- Elettra Sincrotrone Trieste, Trieste, Italy
| | - C Dullin
- Institute for Diagnostic and Interventional Radiology, University Medical Center Göttingen, Göttingen, Germany. .,Elettra Sincrotrone Trieste, Trieste, Italy. .,Translational Molecular Imaging, Max-Planck-Institute for Experimental Medicine, Göttingen, Germany.
| |
Collapse
|
2
|
Ghani MU, Wong MD, Ren L, Wu D, Zheng B, Rong JX, Wu X, Liu H. Characterization of Continuous and Pulsed Emission modes of a Hybrid Micro Focus X-ray Source for Medical Imaging Applications. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT 2017; 853:70-77. [PMID: 28959083 PMCID: PMC5612449 DOI: 10.1016/j.nima.2017.02.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The aim of this study was to quantitatively characterize a micro focus x-ray tube that can operate in both continuous and pulsed emission modes. The micro focus x-ray source (Model L9181-06, Hamamatsu Photonics, Japan) has a varying focal spot size ranging from 16-50 μm as the source output power changes from 10-39 W. We measured the source output, beam quality, focal spot sizes, kV accuracy, spectra shapes and spatial resolution. Source output was measured using an ionization chamber for various tube voltages (kVs) with varying current (μA) and distances. The beam quality was measured in terms of half value layer (HVL), kV accuracy was measured with a non-invasive kV meter, and the spectra was measured using a compact integrated spectrometer system. The focal spot sizes were measured using a slit method with a CCD detector with a pixel pitch of 22 μm. The spatial resolution was quantitatively measured using the slit method with a CMOS flat panel detector with a 50 μm pixel pitch, and compared to the qualitative results obtained by imaging a contrast bar pattern. The focal spot sizes in the vertical direction were smaller than that of the horizontal direction, the impact of which was visible when comparing the spatial resolution values. Our analyses revealed that both emission modes yield comparable imaging performances in terms of beam quality, spectra shape and spatial resolution effects. There were no significantly large differences, thus providing the motivation for future studies to design and develop stable and robust cone beam imaging systems for various diagnostic applications.
Collapse
Affiliation(s)
- Muhammad U. Ghani
- Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA
| | - Molly D. Wong
- Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA
| | - Liqiang Ren
- Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA
| | - Di Wu
- Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA
| | - Bin Zheng
- Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA
| | - John X. Rong
- Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - Xizeng Wu
- Department of Radiology, University of Alabama at Birmingham, Birmingham, AL, 35249, USA
| | - Hong Liu
- Center for Biomedical Engineering and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK, 73019, USA
| |
Collapse
|
3
|
Paumgartten FJR. On the persistence of rat axial skeleton anomalies after birth. Reprod Toxicol 2016; 60:167-8. [PMID: 26923736 DOI: 10.1016/j.reprotox.2016.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2015] [Accepted: 02/20/2016] [Indexed: 11/24/2022]
Affiliation(s)
- Francisco J R Paumgartten
- Laboratory of Environmental Toxicology, National School of Public Health, Oswaldo Cruz Foundation, Rio de Janeiro, RJ 21040-361, Brazil.
| |
Collapse
|
4
|
Chahoud I, Talsness CE, Walter A, Grote K. Response to Dr. Francisco Paumgartten's letter to the Editor: "On the persistence of rat axial skeleton anomalies after birth". Reprod Toxicol 2016; 60:169-70. [PMID: 26923260 DOI: 10.1016/j.reprotox.2016.02.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2015] [Revised: 02/22/2016] [Accepted: 02/22/2016] [Indexed: 10/22/2022]
Affiliation(s)
- Ibrahim Chahoud
- Institute of Clinical Pharmacology and Toxicology, Charité University Medical School Berlin,Charitéplatz 1, 10117 Berlin, Germany
| | - Chris E Talsness
- Institute of Clinical Pharmacology and Toxicology, Charité University Medical School Berlin,Charitéplatz 1, 10117 Berlin, Germany
| | - Alice Walter
- Institute of Clinical Pharmacology and Toxicology, Charité University Medical School Berlin,Charitéplatz 1, 10117 Berlin, Germany
| | - Konstanze Grote
- Institute of Clinical Pharmacology and Toxicology, Charité University Medical School Berlin,Charitéplatz 1, 10117 Berlin, Germany.
| |
Collapse
|
5
|
Chahoud I, Talsness C, Walter A, Grote K. Postnatal investigation of prenatally induced effects on the vertebral column of rats reduces the uncertainty of classification of anomalies. Reprod Toxicol 2015. [DOI: 10.1016/j.reprotox.2015.07.078] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|