1
|
Lo Feudo CM, Ferrucci F, Bizzotto D, Dellacà R, Lavoie J, Stucchi L. Differences in pulmonary function measured by oscillometry between horses with mild-moderate equine asthma and healthy controls. Equine Vet J 2025; 57:619-628. [PMID: 39134475 PMCID: PMC11982413 DOI: 10.1111/evj.14206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 07/01/2024] [Indexed: 04/11/2025]
Abstract
BACKGROUND The diagnosis of mild-moderate equine asthma (MEA) can be confirmed by airway endoscopy, bronchoalveolar lavage fluid (BALf) cytology, and lung function evaluation by indirect pleural pressure measurement. Oscillometry is a promising pulmonary function test method, but its ability to detect subclinical airway obstruction has been questioned. OBJECTIVES To evaluate the differences in lung function measured by oscillometry between healthy and MEA-affected horses. STUDY DESIGN Prospective case-control clinical study. METHODS Thirty-seven horses were divided into healthy and MEA groups, based on history and clinical score; the diagnosis of MEA was confirmed by airway endoscopy and BALf cytology. Horses underwent oscillometry at frequencies ranging from 2 to 6 Hz. Obtained parameters included whole-breath, inspiratory, expiratory, and the difference between inspiratory and expiratory resistance (Rrs) and reactance (Xrs). Differences between oscillometry parameters at different frequencies were evaluated within and between groups by repeated-measures two-way ANOVA and post hoc tests with Bonferroni correction. Frequency dependence was compared between groups by t test. For significant parameters, a receiver operating characteristics curve was designed, cut-off values were identified and their sensitivity and specificity were calculated. Statistical significance was set at p < 0.05. RESULTS No significant differences in Xrs and Rrs were observed between groups. The frequency dependence of whole-breath and inspiratory Xrs significantly differed between healthy (respectively, -0.03 ± 0.02 and -0.05 ± 0.02 cmH2O/L/s) and MEA (-0.1 ± 0.03 and -0.2 ± 0.02 cmH2O/L/s) groups (p < 0.05 and p < 0.01). For inspiratory Xrs frequency dependence, a cut-off value of -0.06 cmH2O/L/s was identified, with 86.4% (95% CI: 66.7%-95.3%) sensitivity and 66.7% (95% CI: 41.7%-84.8%) specificity. MAIN LIMITATIONS Sample size, no BALf cytology in some healthy horses. CONCLUSIONS Oscillometry can represent a useful non-invasive tool for the diagnosis of MEA. Specifically, the evaluation of the frequency dependence of Xrs may be of special interest.
Collapse
Affiliation(s)
- Chiara Maria Lo Feudo
- Equine Sports Medicine Laboratory “Franco Tradati”, Department of Veterinary Medicine and Animal SciencesUniversità Degli Studi di MilanoLodiItaly
| | - Francesco Ferrucci
- Equine Sports Medicine Laboratory “Franco Tradati”, Department of Veterinary Medicine and Animal SciencesUniversità Degli Studi di MilanoLodiItaly
| | - Davide Bizzotto
- TechRes Lab, Department of Electronics, Information and Biomedical EngineeringPolitecnico di MilanoMilanItaly
| | - Raffaele Dellacà
- TechRes Lab, Department of Electronics, Information and Biomedical EngineeringPolitecnico di MilanoMilanItaly
| | - Jean‐Pierre Lavoie
- Department of Clinical Sciences, Faculty of Veterinary MedicineUniversité de MontréalSaint‐HyacintheQuebecCanada
| | - Luca Stucchi
- Department of Veterinary MedicineUniversità degli Studi di SassariSassariItaly
| |
Collapse
|
2
|
Mainguy-Seers S, Diaw M, Lavoie JP. Lung Function Variation during the Estrus Cycle of Mares Affected by Severe Asthma. Animals (Basel) 2022; 12:ani12040494. [PMID: 35203202 PMCID: PMC8868231 DOI: 10.3390/ani12040494] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 01/15/2022] [Accepted: 02/12/2022] [Indexed: 12/04/2022] Open
Abstract
Simple Summary The estrus cycle and sex hormones influence asthma development and severity in humans, but whether the same is occurring in the asthma of horses is unknown. Severe equine asthma (SEA) is characterized by breathing difficulty, even at rest, and although it can be controlled by management and medication, it remains incurable. Stabling and hay feeding are the main contributors to disease exacerbation, but other factors could possibly alter the respiratory compromise. Therefore, the objective of this study was to evaluate the effects of the estrus cycle on airway dysfunction in five mares affected by SEA by assessing the lung function during the follicular and luteal phases of the reproductive cycle. The inspiratory obstruction improved during the luteal phase and the variation in progesterone and the dominant follicle size correlated with lung function parameters, suggesting a role for sex hormones in asthma pathophysiology. This first description of the estrus cycle’s modulation of airway obstruction in horses supports further studies to uncover the effects of sex hormones in asthma in horses and humans. Abstract While the prevalence of asthma is higher in boys than in girls during childhood, this tendency reverses at puberty, suggesting an effect of sex hormones on the disease pathophysiology. Fluctuations of asthma severity concurring with the estrus cycle are reported in women, but this phenomenon has never been investigated in mares to date. The objective of this exploratory study was to determine whether the estrus cycle modulates airway obstruction in severe equine asthma (SEA). Five mares with SEA during exacerbation of the disease were studied. The whole breath, expiratory and inspiratory resistance, and reactance were compared during the follicular and luteal phases of the estrus cycle. The reproductive tract was evaluated by rectal palpation, ultrasound, and serum progesterone levels. The inspiratory resistance and reactance improved during the luteal phase of the estrus cycle, and variation in progesterone levels and the dominant follicle size correlated with several lung function parameters. The fluctuation of airway dysfunction during the estrus cycle is noteworthy as deterioration of the disease could perhaps be expected and prevented by horse owners and veterinarians. Further studies are required to determine if the equine species could be a suitable model to evaluate the effects of sex hormones on asthma.
Collapse
|
3
|
Kozłowska N, Wierzbicka M, Jasiński T, Domino M. Advances in the Diagnosis of Equine Respiratory Diseases: A Review of Novel Imaging and Functional Techniques. Animals (Basel) 2022; 12:381. [PMID: 35158704 PMCID: PMC8833607 DOI: 10.3390/ani12030381] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 02/02/2022] [Accepted: 02/03/2022] [Indexed: 02/04/2023] Open
Abstract
The horse, as a flight animal with a survival strategy involving rapid escape from predators, is a natural-born athlete with enormous functional plasticity of the respiratory system. Any respiratory dysfunction can cause a decline in ventilation and gas exchange. Therefore, respiratory diseases often lead to exercise intolerance and poor performance. This is one of the most frequent problems encountered by equine internists. Routine techniques used to evaluate respiratory tract diseases include clinical examination, endoscopic examination, radiographic and ultrasonographic imaging, cytological evaluation, and bacterial culture of respiratory secretions. New diagnostic challenges and the growing development of equine medicine has led to the implementation of advanced diagnostic techniques successfully used in human medicine. Among them, the use of computed tomography (CT) and magnetic resonance (MR) imaging significantly broadened the possibilities of anatomical imaging, especially in the diagnosis of upper respiratory tract diseases. Moreover, the implementation of spirometry, electrical impedance tomography (EIT), and impulse oscillation system (IOS) sheds new light on functional diagnostics of respiratory tract diseases, especially those affecting the lower part. Therefore, this review aimed to familiarize the clinicians with the advantages and disadvantages of the advanced diagnostic techniques of the equine respiratory tract and introduce their recent clinical applications in equine medicine.
Collapse
Affiliation(s)
| | - Małgorzata Wierzbicka
- Department of Large Animal Diseases and Clinic, Institute of Veterinary Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland; (N.K.); (T.J.)
| | | | - Małgorzata Domino
- Department of Large Animal Diseases and Clinic, Institute of Veterinary Medicine, Warsaw University of Life Sciences, 02-787 Warsaw, Poland; (N.K.); (T.J.)
| |
Collapse
|
4
|
Bizzotto D, Paganini S, Stucchi L, Palmisano Avallone M, Ramirez EM, Pompilio PP, Ferrucci F, Lavoie JP, Dellaca RL. A portable fan-based device for evaluating lung function in horses by the forced oscillation technique. Physiol Meas 2022; 43. [PMID: 35120344 DOI: 10.1088/1361-6579/ac522e] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Accepted: 02/04/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The assessment of lung mechanics in horses is nowadays based on invasive methods that may require sedation. The forced oscillation technique (FOT) allows the non-invasive assessment of respiratory mechanics during spontaneous breathing, but current devices are complex, cumbersome, expensive, and difficult to be applied in horses. APPROACH We developed a portable FOT device based on a novel approach in which the pressure waveforms are generated by a servo-controlled ducted fan. This new approach allows the design of devices that are more sturdy, compact, and portable compared to already existing approaches. The prototype includes 1) a small microcontroller-based electronic board for controlling the fan and measuring flow and pressure and 2) an optimized data processing algorithm. MAIN RESULTS This device provides a maximum error of 0.06 cmH2O∙s/L and 0.15 cmH2O∙s/L in measuring respiratory resistance and reactance during in-vitro validation. A pilot study was also performed on three healthy horses and three horses with severe equine asthma (SEA) and it demonstrated good tolerability and feasibility of the new device. Total respiratory system resistance (Rrs) and reactance (Xrs) significantly differed (p<0.05) between groups. At 5Hz, Rrs was 0.66±0.02 cmH2O∙s/L and 0.94±0.07 cmH2O∙s/L in healthy and in SEA, respectively. Xrs 0.38±0.02 cmH2O∙s/L and -0.27±0.05 cmH2O∙s/L. SIGNIFICANCE This novel approach for applying FOT allowed the development of a small, affordable and portable device for the non-invasive evaluation of respiratory mechanics in spontaneously breathing horses, providing a useful new tool for improving veterinary respiratory medicine. Moreover, our results provide supporting evidence of the value of this novel approach for developing portable FOT devices also for applications in humans.
Collapse
Affiliation(s)
- Davide Bizzotto
- DEIB, Politecnico di Milano Dipartimento di Elettronica Informazione e Bioingegneria, Via Giuseppe Colombo, 40, Milano, 20133, ITALY
| | - Stefano Paganini
- DEIB, Politecnico di Milano Dipartimento di Elettronica Informazione e Bioingegneria, Via Giuseppe Colombo, 40, Milano, Milano, 20133, ITALY
| | - Luca Stucchi
- Equine Sports Medicine Lab (ESM-Lab), Università degli Studi di Milano Dipartimento di Medicina Veterinaria, Via dell'Università, 6, 26900 Lodi LO, Lodi, Lombardia, 26900, ITALY
| | - Matteo Palmisano Avallone
- DEIB, Politecnico di Milano Dipartimento di Elettronica Informazione e Bioingegneria, Via Giuseppe Colombo, 40, Milano, Milano, 20133, ITALY
| | - Esther Millares Ramirez
- Equine Asthma Laboratory, Université de Montréal Faculté de médecine vétérinaire, 3200 Rue Sicotte, Saint-Hyacinthe, QC J2S 2M2, Canada, Saint Hyacinthe, Quebec, J2S 7C6, CANADA
| | - Pasquale P Pompilio
- Restech srl, Via Melchiorre Gioia, 61, 20124 Milano MI, Milano, 20124, ITALY
| | - Francesco Ferrucci
- Equine Sports Medicine Lab (ESM-Lab), Università degli Studi di Milano Dipartimento di Medicina Veterinaria, Via dell'Università, 6, 26900 Lodi LO, Lodi, Lombardia, 26900, ITALY
| | - Jean-Pierre Lavoie
- Equine Asthma Laboratory, Université de Montréal Faculté de médecine vétérinaire, 3200 Rue Sicotte, Saint-Hyacinthe, QC J2S 2M2, Canada, Saint Hyacinthe, Quebec, J2S 2M2, CANADA
| | - Raffaele L Dellaca
- DEIB, Politecnico di Milano Dipartimento di Elettronica e Informazione, Via Giuseppe Colombo, 40, Milano, Milano, Lombardia, 20133, ITALY
| |
Collapse
|
5
|
Stucchi L, Ferrucci F, Bullone M, Dellacà RL, Lavoie JP. Within-Breath Oscillatory Mechanics in Horses Affected by Severe Equine Asthma in Exacerbation and in Remission of the Disease. Animals (Basel) 2021; 12:ani12010004. [PMID: 35011110 PMCID: PMC8749667 DOI: 10.3390/ani12010004] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 12/14/2021] [Accepted: 12/17/2021] [Indexed: 12/19/2022] Open
Abstract
Oscillometry is a technique that measures the resistance (R) and the reactance (X) of the respiratory system. In humans, analysis of inspiratory and expiratory R and X allows to identify the presence of tidal expiratory flow limitation (EFLt). The aim of this study was to describe inspiratory and expiratory R and X measured by impulse oscillometry system (IOS) in horses with severe asthma (SEA) when in clinical remission (n = 7) or in exacerbation (n = 7) of the condition. Seven healthy, age-matched control horses were also studied. Data at 3, 5, and 7 Hz with coherence > 0.85 at 3 Hz and >0.9 at 5 and 7 Hz were considered. The mean, inspiratory and expiratory R and X and the difference between inspiratory and expiratory X (ΔX) were calculated at each frequency. The data from the three groups were statistically compared. Results indicated that in horses during exacerbation of severe asthma, X during expiratory phase is more negative than during inspiration, such as in humans in presence of EFLt. The evaluation of X during inspiration is promising in discriminating between horses with SEA in remission and control horses.
Collapse
Affiliation(s)
- Luca Stucchi
- Dipartimento di Medicina Veterinaria, Università degli Studi di Milano, 26900 Lodi, Italy;
| | - Francesco Ferrucci
- Dipartimento di Medicina Veterinaria, Università degli Studi di Milano, 26900 Lodi, Italy;
- Correspondence:
| | - Michela Bullone
- Dipartimento di Scienze Veterinarie, Università di Torino, 10095 Grugliasco, Italy;
| | - Raffaele L. Dellacà
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, 20133 Milano, Italy;
| | - Jean Pierre Lavoie
- Département de Sciences Cliniques, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, QC J2S 2M2, Canada;
| |
Collapse
|
6
|
Effects of sedation and salbutamol administration on hyperpnoea and tidal breathing spirometry in healthy horses. Vet J 2017; 222:22-28. [PMID: 28410672 DOI: 10.1016/j.tvjl.2017.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2016] [Revised: 02/26/2017] [Accepted: 03/05/2017] [Indexed: 11/20/2022]
Abstract
Sedation is often required to perform pulmonary function testing (PFT) in horses, but drug effects may influence respiratory function. The current study was designed to characterise the effects of sedation and bronchodilator administration on absolute and relative indices of pulmonary function during eupnoeic respiration and carbon dioxide-induced hyperpnoea (rebreathing) in healthy horses using a pneumotachographic spirometry system. Sedation with acetylpromazine (ACP), xylazine, or both drugs in combination was associated with significant reductions in respiratory frequency, minute ventilation and peak airflows during eupnoeic respiration. Peak expiratory airflow occurred later in the respiratory cycle than was observed in untreated horses, and expiratory relative flow-time indices were also affected during eupnoeic respiration. Rebreathing attenuated the effects of sedation on indices of pulmonary function, suggesting that future studies should consider the use of induced hyperpnoea as part of the spirometry protocol. Based on the finding that all sedative agents had some effect on eupnoeic respiration, albeit least pronounced with ACP, the latter drug should be considered for sedation of horses undergoing PFT. Salbutamol increased peak inspiratory flow during eupnoeic respiration in healthy horses.
Collapse
|
7
|
Bullone M, Hélie P, Joubert P, Lavoie JP. Development of a Semiquantitative Histological Score for the Diagnosis of Heaves Using Endobronchial Biopsy Specimens in Horses. J Vet Intern Med 2016; 30:1739-1746. [PMID: 27527123 PMCID: PMC5032871 DOI: 10.1111/jvim.14556] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Revised: 06/03/2016] [Accepted: 07/06/2016] [Indexed: 12/11/2022] Open
Abstract
Background Remodeling of the peripheral airways persists during the asymptomatic phase of heaves. Assessing the histology of large bronchi could facilitate the diagnosis of heaves during remission of the disease. Hypothesis Airway inflammation and remodeling in endobronchial biopsy (EBB) specimens differentiate horses with heaves from controls, independently of their clinical status (exacerbation or remission). Animals Fourteen healthy horses and 24 horses with heaves. Methods A 14‐point scoring system assessing central bronchial wall inflammation and remodeling was developed. The score was validated by 2 pathologists using specimens obtained from 18 horses (6 controls, 6 with heaves exacerbation, and 6 with heaves remission) in which lung function had been assessed with impulse oscillometry. Clinical and research application of the score was evaluated using biopsy specimens obtained from 20 additional horses (8 controls, 6 with heaves exacerbation, and 6 with heaves remission). Results The score was repeatable (interclass correlation coefficient = 69%). It differentiated horses with heaves in exacerbation (mean ± SD: 6.2 ± 2.2) from those in remission (4.0 ± 1.0) and controls (3.6 ± 1.7, P < 0.0001). The histological scores of horses with heaves correlated with the ratio of respiratory resistance (R) at 5 and 10 Hz (R5 : R10 ratio, r = 0.65, P = 0.03), a parameter assessing airway obstruction. Conclusions and Clinical Significance The proposed histological scoring system correlates with the degree of airway obstruction measured by impulse oscillometry. However, it does not discriminate horses with heaves in remission from controls. Evaluation of EBB specimens might be considered in future research and clinical studies of respiratory diseases in horses.
Collapse
Affiliation(s)
- M Bullone
- Department of Clinical Sciences, Université de Montréal, St-Hyacinthe, QC, Canada
| | - P Hélie
- Department of Pathology and Microbiology, Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, QC, Canada
| | - P Joubert
- Institut Universitaire de Cardiologie et de Pneumologie de Québec, Université Laval, Quebec, QC, Canada
| | - J-P Lavoie
- Department of Clinical Sciences, Université de Montréal, St-Hyacinthe, QC, Canada.
| |
Collapse
|
8
|
Bullone M, Chevigny M, Allano M, Martin JG, Lavoie JP. Technical and physiological determinants of airway smooth muscle mass in endobronchial biopsy samples of asthmatic horses. J Appl Physiol (1985) 2014; 117:806-15. [PMID: 25103978 DOI: 10.1152/japplphysiol.00468.2014] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Morphometric analyses of endobronchial biopsies are commonly performed in asthma research but little is known about the technical and physiological parameters contributing to measurement variability. We investigated factors potentially affecting biopsy size, quality, and airway smooth muscle (ASM) content in heaves, an asthma-like disease of horses. Horses with heaves in clinical exacerbation (n = 6) or remission (n = 6) from the disease and six controls were studied using a crossover design. The effect of disease status, age, bronchodilation, biopsy forceps type, and carina size on total biopsy area (Atot), ASM area (AASM), ASM% (AASM/Atot), and histologic quality were assessed. Concordance among different measuring techniques was also assessed. Compared with other groups, horses with heaves in exacerbation yielded larger biopsies (P < 0.05). Better quality biopsies were obtained from carinae of small size compared with large ones (P = 0.02), and carina size and forceps type significantly affected the ASM content of the biopsy (interaction, P < 0.05). AASM increased with age only in heaves-affected horses (r = 0.9, P < 0.05), and ASM% was negatively correlated with pulmonary resistance at 5 Hz in heaves-affected horses (r = -0.74, P = 0.01), likely because of the increased thickness of the extracellular matrix layer in this group (P = 0.01). In conclusion, disease status, carina thickness, and the forceps used may significantly affect biopsy size, quality, and ASM content. Endobronchial biopsies are not appropriate samples for ASM quantification in heaves, and studies measuring ASM mass should not be compared when measuring techniques differ.
Collapse
Affiliation(s)
- Michela Bullone
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Québec, Canada; and
| | - Mylène Chevigny
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Québec, Canada; and
| | - Marion Allano
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Québec, Canada; and
| | - James G Martin
- Meakins-Christie Laboratories, Department of Medicine, McGill University, Montréal, Québec, Canada
| | - Jean-Pierre Lavoie
- Department of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, Québec, Canada; and
| |
Collapse
|
9
|
Daily variability of forced oscillometry parameters in horses suffering recurrent airway obstruction, a pilot study. Vet Res Commun 2012; 37:11-7. [DOI: 10.1007/s11259-012-9541-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/04/2012] [Indexed: 10/27/2022]
|
10
|
Wagner AE, Mama KR, Contino EK, Ferris DJ, Kawcak CE. Evaluation of sedation and analgesia in standing horses after administration of xylazine, butorphanol, and subanesthetic doses of ketamine. J Am Vet Med Assoc 2011; 238:1629-33. [DOI: 10.2460/javma.238.12.1629] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
11
|
Richard EA, Fortier GD, Denoix JM, Art T, Lekeux PM, Van Erck E. Influence of subclinical inflammatory airway disease on equine respiratory function evaluated by impulse oscillometry. Equine Vet J 2009; 41:384-9. [PMID: 19562901 DOI: 10.2746/042516409x366121] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
REASONS FOR PERFORMING STUDY Inflammatory airway disease (IAD) is a nonseptic condition of the lower respiratory tract. Its negative impact on respiratory function has previously been described using either forced expiration or forced oscillations techniques. However, sedation or drug-induced bronchoconstriction were usually required. The impulse oscillometry system (IOS) is a noninvasive and sensitive respiratory function test validated in horses, which could be useful to evaluate IAD-affected horses without further procedures. OBJECTIVES To determine the sensitivity of IOS in detecting alterations of the respiratory function in subclinically IAD-affected horses without inducing bronchoprovocation and to characterise their respiratory impedance according to frequency for each respiratory phase. METHODS Pulmonary function was evaluated at rest by IOS in 34 Standardbred trotters. According to the cytology of bronchoalveolar lavage fluid (BALF), 19 horses were defined as IAD-affected and 15 horses were used as control (CTL). Total respiratory resistance (Rrs) and reactance (Xrs) from 1-20 Hz as well as their inspiratory and expiratory components were compared between groups. RESULTS A significant increase of Rrs at the lower frequencies (R1-10 Hz) as well as a significant decrease of Xrs beyond 5 Hz (X5-20 Hz) was observed in IAD compared to CTL horses. IOS-data was also significantly different between inspiration and expiration in IAD-affected horses. In the whole population, both BALF eosinophil and mast cell counts were significantly correlated with IOS measurements. CONCLUSIONS Functional respiratory impairment may be measured, even in the absence of clinical signs of disease. In IAD-affected horses, the different parameters of respiratory function (Rrs or Xrs) may vary depending on the inflammatory cell profiles represented in BALF. POTENTIAL RELEVANCE Impulse oscillometry could be used in a routine clinical setting as a noninvasive method for early detection of subclinical respiratory disease and of the results of treatment in horses.
Collapse
Affiliation(s)
- E A Richard
- Department of Physiology, Faculty of Veterinary Medicine, Bat. B42, University of Liège, 20 Boulevard de Colonster, 4000 Liège, Belgium
| | | | | | | | | | | |
Collapse
|