1
|
Sheng Y, Xu K, Wang Z, Gao Y. A colorimetric and ratiometric fluorescent probe of hypochlorous acid and its bio-imaging application. Photochem Photobiol Sci 2025; 24:65-77. [PMID: 39704907 DOI: 10.1007/s43630-024-00672-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2024] [Accepted: 11/29/2024] [Indexed: 12/21/2024]
Abstract
A new ratiometric and colorimetric fluorescent probe HTD was synthesized based on the reaction of 4-aminophenyl boronic acid pinacol ester and 4-(3-formyl-4-hydroxyphenyl) benzonitrile. The probe exhibited a unique fluorescence response to hypochlorous acid and had good anti-interference performance in the presence of other interference. When HTD met the NaClO, the light orange fluorescence was changed to green with the blue-shifted emission wavelength from 550 to 500 nm. Moreover, the absorbance of HTD's UV-vis at 300 nm and 375 nm decreased in the presence of NaClO. The limit of detection was 1.83 × 10-7 M and 2.96 × 10-6 M based on the fluorescence and UV-vis titration data. NMR, HRMS, and IR spectra suggested that the possible sensing mechanism of HTD to NaClO was the formation of initial compound 4-(3-formyl-4-hydroxyphenyl) benzonitrile due to the oxidation of hypochlorous acid in aqueous solution. The portable test strips were obtained, and the real water sample test reached good results with spiking recoveries among 92.00% ~ 103.25%. Finally, endogenous hypochlorous acid produced by LPS and PMA was successfully detected by HTD in living mice using in situ fluorescence bioimaging.
Collapse
Affiliation(s)
- Yumiao Sheng
- State Key Laboratory Breeding Base of Green Chemistry Synthesis Technology, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310032, China
| | - Kedian Xu
- State Key Laboratory Breeding Base of Green Chemistry Synthesis Technology, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310032, China
| | - Zhenzhen Wang
- State Key Laboratory Breeding Base of Green Chemistry Synthesis Technology, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310032, China
| | - Yunling Gao
- State Key Laboratory Breeding Base of Green Chemistry Synthesis Technology, College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310032, China.
| |
Collapse
|
2
|
Shao Y, Sun J, Li P, Gao CY, Yang Y. A triphenylamine-based carbohydrazide hydrazone fluorescent probe for selective detection of hypochlorite and sensing acidic gases. LUMINESCENCE 2024; 39:e4726. [PMID: 38511249 DOI: 10.1002/bio.4726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Revised: 01/31/2024] [Accepted: 02/27/2024] [Indexed: 03/22/2024]
Abstract
Hypochlorous acid and its hypochlorite are important reactive oxygen species in the body, and are involved in various physiological processes related to immunity; their rapid detection is of great significance. Here, we synthesized a fluorescent probe (TPAS) by condensation of 4-(diphenylamino)benzaldehyde, carbohydrazide, and salicylaldehyde, which can be used for the detection of ClO- in water and sensing of acidic gas in its solid state. The probe showed strong selective recognition of ClO- in acetonitrile and good tolerance to interference ions. There were good linear responses between the intensity of absorbance and fluorescence and the amount of ClO-. The TPAS solid and its paper strips can emit red fluorescence when exposed to volatile acidic vapours. After being treated with NH3, the red fluorescence can be restored to yellow. The response process of TPAS to ClO- and acid gases was characterized using nuclear magnetic resonance, electrospray ionisation mass spectrometry, transmission electron microscopy, and density functional theory calculations. Furthermore, it can be utilized in analyzing ClO- in commercially available bleaching products; the detection results were basically compatible with the labelled values. In addition, the probe is biocompatible and can be applied for imaging ClO- in zebrafish.
Collapse
Affiliation(s)
- Yuxin Shao
- Inner Mongolia Key Laboratory for the Natural Products Chemistry and Functional Molecular Synthesis; College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, China
| | - Jingxuan Sun
- Inner Mongolia Key Laboratory for the Natural Products Chemistry and Functional Molecular Synthesis; College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, China
| | - Peng Li
- Department of Chemistry, Faculty of Science, Beihua University, Jilin, China
| | - Chao-Ying Gao
- Inner Mongolia Key Laboratory for the Natural Products Chemistry and Functional Molecular Synthesis; College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, China
| | - Yang Yang
- Inner Mongolia Key Laboratory for the Natural Products Chemistry and Functional Molecular Synthesis; College of Chemistry and Materials Science, Inner Mongolia Minzu University, Tongliao, China
| |
Collapse
|
3
|
Du M, Zhang Y, Xu Z, Dong Z, Zhao S, Du H, Zhao H. Point-of-Care and Dual-Response Detection of Hydrazine/Hypochlorite-Based on a Smart Hydrogel Sensor and Applications in Information Security and Bioimaging. Molecules 2023; 28:3896. [PMID: 37175308 PMCID: PMC10180410 DOI: 10.3390/molecules28093896] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/18/2023] [Accepted: 04/21/2023] [Indexed: 05/15/2023] Open
Abstract
A novel dual-response fluorescence probe (XBT-CN) was developed by using a fluorescence priming strategy for quantitative monitoring and visualization of hydrazine (N2H4) and hypochlorite (ClO-). With the addition of N2H4/ClO-, the cleavage reaction of C=C bond initiated by N2H4/ClO- was transformed into corresponding hydrazone and aldehyde derivatives, inducing the probe XBT-CN appeared a fluorescence "off-on" response, which was verified by DFT calculation. HRMS spectra were also conducted to confirm the sensitive mechanism of XBT-CN to N2H4 and ClO-. The probe XBT-CN had an obvious fluorescence response to N2H4 and ClO-, which caused a significant color change in unprotected eyes. In addition, the detection limits of XBT-CN for N2H4 and ClO- were 27 nM and 34 nM, respectively. Interference tests showed that other competitive analytes could hardly interfere with the detection of N2H4 and ClO- in a complex environment. In order to realize the point-of-care detection of N2H4 and ClO-, an XBT-CN@hydrogel test kit combined with a portable smartphone was developed. Furthermore, the portable test kit has been applied to the detection of N2H4 and ClO- in a real-world environment and food samples, and a series of good results have been achieved. Attractively, we demonstrated that XBT-CN@hydrogel was successfully applied as an encryption ink in the field of information security. Finally, the probe can also be used to monitor and distinguish N2H4 and ClO- in living cells, exhibiting excellent biocompatibility and low cytotoxicity.
Collapse
Affiliation(s)
- Man Du
- College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Yue Zhang
- College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Zhice Xu
- College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Zhipeng Dong
- Hebei Lansheng Biotech Co., Ltd., Shijiazhuang 052260, China
| | - Shuchun Zhao
- College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Hongxia Du
- College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
| | - Hua Zhao
- College of Chemical and Pharmaceutical Engineering, Hebei University of Science and Technology, Shijiazhuang 050018, China
| |
Collapse
|
4
|
Chen X, Jiang D, Jiang C, Yao C. A novel near-infrared ratiometric fluorescent probe targeting lysosomes for imaging HOCl in vitro and in vivo. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 286:121966. [PMID: 36252305 DOI: 10.1016/j.saa.2022.121966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 09/21/2022] [Accepted: 10/06/2022] [Indexed: 06/16/2023]
Abstract
Hypochlorous acid (HOCl), as an important biological reactive oxygen species (ROS), plays an important role in microbial immune defense and inflammatory response. Abnormal levels of HOCl in lysosomes can cause lysosomal membrane rupture and release of various hydrolases, leading to a variety of diseases, including cancer. In order to better monitor the level of HOCl in lysosomes, phenothiazine was chosen as fluorophore to construct a NIR fluorescent probe PMM with intramolecular change transfer process (ICT). PMM is a colorimetric and ratiometric fluorescent probe, which has high sensitivity with a low detection limit (20 nM), high selectivity and anti-interference. PMM has good stability in the weakly acidic environment of pH 4.0-5.5. PPM has good localization ability for lysosomes and has been successfully used for fluorescence imaging of exogenous and endogenous HOCl in HepG2 cells. Moreover, nude mouse imaging also demonstrated that PMM could be used to detect HOCl in vivo.
Collapse
Affiliation(s)
- Xiong Chen
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211816, PR China.
| | - Detao Jiang
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211816, PR China.
| | - Chen Jiang
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211816, PR China.
| | - Cheng Yao
- College of Chemistry and Molecular Engineering, Nanjing Tech University, Nanjing 211816, PR China.
| |
Collapse
|
5
|
Liu CX, Xiao SY, Gong XL, Zhu X, Wang YW, Peng Y. A Near-Infrared Fluorescent Probe for Recognition of Hypochlorite Anions Based on Dicyanoisophorone Skeleton. MOLECULES (BASEL, SWITZERLAND) 2023; 28:molecules28010402. [PMID: 36615593 PMCID: PMC9823594 DOI: 10.3390/molecules28010402] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Revised: 12/23/2022] [Accepted: 12/24/2022] [Indexed: 01/09/2023]
Abstract
A novel near-infrared (NIR) fluorescent probe (SWJT-9) was designed and synthesized for the detection of hypochlorite anion (ClO-) using a diaminomaleonitrile group as the recognition site. SWJT-9 had large Stokes shift (237 nm) and showed an excellent NIR fluorescence response to ClO- with the color change under the visible light. It showed a low detection limit (24.7 nM), high selectivity, and rapid detection (within 2 min) for ClO-. The new detection mechanism of SWJT-9 on ClO- was confirmed by 1H NMR, MS spectrum, and the density functional theory (DFT) calculations. In addition, the probe was successfully used to detect ClO- in HeLa cells.
Collapse
Affiliation(s)
- Chang-Xiang Liu
- School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Shu-Yuan Xiao
- School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Xiu-Lin Gong
- School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Xi Zhu
- Department of Neurology, The Third People’s Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu 610031, China
- Correspondence: (X.Z.); (Y.-W.W.)
| | - Ya-Wen Wang
- School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
- Correspondence: (X.Z.); (Y.-W.W.)
| | - Yu Peng
- School of Life Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| |
Collapse
|
6
|
Ma Y, Wu Y, Wang X, Gao G, Zhou X. Research Progress of Near-Infrared Fluorescent Probes Based on 1,3-Dichloro-7-hydroxy-9,9-dimethyl-2(9 H)-acridone (DDAO). CHINESE J ORG CHEM 2023. [DOI: 10.6023/cjoc202206044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
7
|
Vijay N, Magesh K, M RL, Velmathi S. Recent Advancements in the Design and Development of Near Infrared (NIR) Emitting Fluorescent Probes for Sensing and their Bio-Imaging Applications. Curr Org Synth 2023; 20:114-175. [PMID: 35260055 DOI: 10.2174/1570179419666220308145901] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 01/05/2022] [Accepted: 01/11/2022] [Indexed: 12/16/2022]
Abstract
Fluorescent bio-imaging will be the future in the medical diagnostic for visualising inner cellular and tissues. Near-infrared (NIR) emitting fluorescent probes serve dynamically for targeted fluorescent imaging of live cells and tissues. NIR imaging is advantageous because of its merits like deep tissue penetration, minimum damage to the tissue, reduced auto fluorescence from the background, and improved resolution in imaging. The Development of the NIR emitting probe was well explored recently and growing drastically. In this review, we summarise recent achievements in NIR probes in between 2018-2021. The merits and future applications have also been discussed in this review.
Collapse
Affiliation(s)
- Natarajan Vijay
- Organic and Polymer Synthesis Laboratory, Department of Chemistry, National Institute of Technology, Tiruchirappalli - 620 015, India
| | - Kuppan Magesh
- Organic and Polymer Synthesis Laboratory, Department of Chemistry, National Institute of Technology, Tiruchirappalli - 620 015, India
| | - Renny Louis M
- Organic and Polymer Synthesis Laboratory, Department of Chemistry, National Institute of Technology, Tiruchirappalli - 620 015, India
| | - Sivan Velmathi
- Organic and Polymer Synthesis Laboratory, Department of Chemistry, National Institute of Technology, Tiruchirappalli - 620 015, India
| |
Collapse
|
8
|
Li D, Wang B, Zhang L, Zheng J, Bao H. Rhodol-Based Fluorescent Probes Used for Fast Response toward ClO– and Delayed Determination of H2O2 in Living Cells. SYNTHESIS-STUTTGART 2022. [DOI: 10.1055/a-1786-1584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
AbstractReactive oxygen species (ROS), a class of reactive oxidants, play critical roles in signal transduction, cell metabolism, immune defense, and other physiological processes. Abnormally excessive levels of ROS can cause diseases and thus, investigations into the relevant biology and medicine are significant. The behavior of ROS in inflammation has been rarely elucidated. In this work, two ROS fluorescent probes, FS-ROS1 and FS-ROS2 have been designed and synthesized. FS-ROS1 responds rapidly (~1 min) to ClO– and gradually (~30 min) to H2O2 with an increase in fluorescence at ~656 nm and 640 nm of more than 100-fold in vitro. At a concentration of 10 μM, FS-ROS1 labels the L929 cell and Raw264.7 cell wells in 30 min with excellent biocompatibility and without washing. After labelling, FS-ROS1 exhibited a rational fluorescence increase upon the addition of 1, 10, 100, and 200 μM of H2O2. Based on these results, inflammatory cells, stimulated with 800 nM dexamethasone and polyIC, showed a higher increase in fluorescence than the control cells. These results suggest that H2O2 and ClO– might be important signaling molecules during inflammations.
Collapse
Affiliation(s)
- Daliang Li
- Fujian Key Laboratory of Innate Immune Biology, Biomedical Research Center of South China, Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education & College of Life Sciences, Fujian Normal University
| | - Bo Wang
- Fujian Key Laboratory of Innate Immune Biology, Biomedical Research Center of South China, Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education & College of Life Sciences, Fujian Normal University
| | - Lanlan Zhang
- Fujian Key Laboratory of Innate Immune Biology, Biomedical Research Center of South China, Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education & College of Life Sciences, Fujian Normal University
| | - Jianpei Zheng
- Fujian Key Laboratory of Innate Immune Biology, Biomedical Research Center of South China, Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education & College of Life Sciences, Fujian Normal University
| | - Hongli Bao
- Key Laboratory of Coal to Ethylene Glycol and Its Related Technology, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences
| |
Collapse
|
9
|
A novel fluorescent probe with large Stokes shift for accurate detection of HOCl in mitochondria and its imaging application. Anal Chim Acta 2022; 1191:339287. [PMID: 35033256 DOI: 10.1016/j.aca.2021.339287] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2021] [Revised: 11/12/2021] [Accepted: 11/15/2021] [Indexed: 11/21/2022]
Abstract
Hypochlorous acid (HOCl), mainly generated in mitochondria, plays a critical role in various physiological processes. To better understand the role and function of HOCl in mitochondria, herein, we present the design and synthesis of a Mito-QL reporter for probing the HOCl within mitochondria without other interference generated in living cells. Through the combination of TICT/ICT mechanisms, probe Mito-QL, with large stokes shift (203 nm) and low background fluorescence, exhibited excellent sensitivity (900-fold fluorescence enhancement) and selectivity towards HOCl (LOD = 2.4 nM). The co-location experiments confirmed that probe Mito-QL can firstly localize in the mitochondria and then react with HOCl in mitochondria. Also, the probe is capable of imaging endogenous and exogenous HOCl even the generation of HOCl during the ferroptosis of cells, which is beneficial for more efficient application in biological imaging.
Collapse
|
10
|
Jiang D, Zhang X, Chen Y, Zhang P, Gong P, Cai L, Wang Y. An α-naphtholphthalein-derived colorimetric fluorescent chemoprobe for the portable and visualized monitoring of Hg 2+ by the hydrolysis mechanism. NEW J CHEM 2022. [DOI: 10.1039/d2nj01051h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
An ɑ-naphtholphthalein-derived colorimetric fluorescent chemoprobe was elaborately designed for the portable and visual monitoring of Hg2+ in environmental and biological samples.
Collapse
Affiliation(s)
- Daoyong Jiang
- Guangdong Key Laboratory of Nanomedicine, CAS Key Laboratory of Health Informatics, Shenzhen Bioactive Materials Engineering Lab for Medicine, Institute of Biomedicine and Biotechnology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Postdoctoral Innovation Practice Base, Shenzhen Polytechnic, Shenzhen 518055, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Xiuwen Zhang
- Guangdong Key Laboratory of Nanomedicine, CAS Key Laboratory of Health Informatics, Shenzhen Bioactive Materials Engineering Lab for Medicine, Institute of Biomedicine and Biotechnology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yizhao Chen
- Guangdong Key Laboratory of Nanomedicine, CAS Key Laboratory of Health Informatics, Shenzhen Bioactive Materials Engineering Lab for Medicine, Institute of Biomedicine and Biotechnology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
- Postdoctoral Innovation Practice Base, Shenzhen Polytechnic, Shenzhen 518055, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Pengfei Zhang
- Guangdong Key Laboratory of Nanomedicine, CAS Key Laboratory of Health Informatics, Shenzhen Bioactive Materials Engineering Lab for Medicine, Institute of Biomedicine and Biotechnology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Ping Gong
- Guangdong Key Laboratory of Nanomedicine, CAS Key Laboratory of Health Informatics, Shenzhen Bioactive Materials Engineering Lab for Medicine, Institute of Biomedicine and Biotechnology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Lintao Cai
- Guangdong Key Laboratory of Nanomedicine, CAS Key Laboratory of Health Informatics, Shenzhen Bioactive Materials Engineering Lab for Medicine, Institute of Biomedicine and Biotechnology, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Yong Wang
- Postdoctoral Innovation Practice Base, Shenzhen Polytechnic, Shenzhen 518055, China
| |
Collapse
|
11
|
Kim A, Lee M, Lee H, So H, Jeong S, Kim KT, Kim C. Detecting and bioimaging of hypochlorite by a conjugated fluorescent chemosensor based on thioamide. J Photochem Photobiol A Chem 2021. [DOI: 10.1016/j.jphotochem.2021.113531] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
12
|
Zhou Y, Xü HJ, Li XJ, Lü CW, An Y. Synthesis and mechanism study of two similar colorimetric fluorescent probes for specific detection of bisulfite and hypochlorite. RESEARCH ON CHEMICAL INTERMEDIATES 2021. [DOI: 10.1007/s11164-021-04625-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
13
|
Ding G, Zuo Y, Gai F, Wang X, Gou Z, Lin W. A POSS-assisted fluorescent probe for the rapid detection of HClO in mitochondria with a large emission wavelength in dual channels. J Mater Chem B 2021; 9:6836-6843. [PMID: 34382057 DOI: 10.1039/d1tb01235e] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Hypochlorous acid (HClO) is closely related to many diseases and is an inevitable part of the physiological processes. It is significant to detect HClO in mitochondria for getting meaningful physiological and pathological information. However, adequate tools to detect HClO with emissions in two channels are rarely reported. To achieve this target, in this work, a "turn-off" visual and near infrared (NIR) fluorescent dual emission probe D6 based on polyhedral oligomeric silsesquioxanes (POSS) was successfully designed and synthesized. D6 showed high selectivity and sensitivity to HClO. Notably, the emission wavelength of D6 reached 820 nm due to the assistance of the POSS cage. In addition, bioimaging experiments clearly showed that probe D6 promoted the visualization of exogenous and endogenous HClO in living HepG2 cells and zebrafish models.
Collapse
Affiliation(s)
- Guowei Ding
- Institute of Fluorescent Probes for Biological Imaging, School of Materials Science and Engineering, School of Chemistry and Chemical Engineering, University of Jinan, Shandong 250022, P. R. China.
| | | | | | | | | | | |
Collapse
|
14
|
Rapid and sensitive detection of hypochlorite in ~100% aqueous solution using a bithiophene-based fluorescent sensor: Application to water analysis and live-cell imaging. J Mol Liq 2020. [DOI: 10.1016/j.molliq.2020.114396] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
|
15
|
Ma C, Zhong G, Zhao Y, Zhang P, Fu Y, Shen B. Recent development of synthetic probes for detection of hypochlorous acid/hypochlorite. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 240:118545. [PMID: 32521447 DOI: 10.1016/j.saa.2020.118545] [Citation(s) in RCA: 77] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 05/23/2020] [Accepted: 05/23/2020] [Indexed: 06/11/2023]
Abstract
Hypochlorous acid/hypochlorite (HOCl/OCl-), as one of the most important reactive oxygen species (ROS), plays an important role in various physiological and pathological processes. Nonproperly located or abnormal concentration of OCl-, however, is associated with many diseases. Thus, developing the fluorescent probe for detecting OCl- is of great significance. To this end, in last decade, many fluorescent probes have been developed and applied for detecting HOCl/OCl- in vitro and in vivo. Despite a great progress has achieved, the development and application of near-infrared fluorescent HOCl/OCl- probe still have some challenges. For example, highly specific and sensitive NIR fluorescent HOCl/OCl- probes applied in endogenous OCl- detection and subcellular organelle bioimaging. In this review, we summarized the representative cases of HOCl/OCl- probes with properties that mentioned above. The discussion contains design strategies, detection mechanisms, as well as applications in bioimaging.
Collapse
Affiliation(s)
- Chenggong Ma
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, Jiangsu 210023, China
| | - Guoyan Zhong
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, Jiangsu 210023, China
| | - Yu Zhao
- Department of Grain Science and Industry, Kansas State University, Manhattan, KS 66506, United States
| | - Ping Zhang
- "Nanjing Normal University-Zhejiang Kingsun Eco-pack" Union Laboratory, Xianju, Zhejiang 317300, China
| | - Yongqian Fu
- "Nanjing Normal University-Zhejiang Kingsun Eco-pack" Union Laboratory, Xianju, Zhejiang 317300, China; School of Life Science, Taizhou University, Jiaojiang, Zhejiang 318000, China
| | - Baoxing Shen
- School of Food Science and Pharmaceutical Engineering, Nanjing Normal University, Nanjing, Jiangsu 210023, China.
| |
Collapse
|
16
|
So H, Lee H, Lee GD, Kim M, Lim MH, Kim KT, Kim C. A thiourea-based fluorescent chemosensor for bioimaging hypochlorite. J IND ENG CHEM 2020. [DOI: 10.1016/j.jiec.2020.06.016] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
17
|
Zhang F, Ma C, Jiao Z, Mu S, Zhang Y, Liu X, Zhang H. A NIR Turn-on Fluorescent Sensor For Detection of Chloride Ions in vitro and in vivo. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 228:117729. [PMID: 31740122 DOI: 10.1016/j.saa.2019.117729] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/11/2019] [Revised: 10/21/2019] [Accepted: 10/28/2019] [Indexed: 06/10/2023]
Abstract
As the most abundant and significant anions in biosystem, chloride ions (Cl-) participate in many important physiological processes. Thus, designing and synthesizing of a simple, sensitive, selective and long wavelength turn-on sensor for the detection and imaging of Cl- in vitro and in vivo is very necessary. Herein, we have developed a simple porphyrin turn-on sensor 5, 10, 15, 20-Tetrakis (4-hydroxyphenyl) porphyrin (THPP) with near infrared emission wavelength (657 nm) for sensing chloride ions with remarkable sensitivity and selectivity. The detection of chloride ions was according to metal displacement assay (MDA) under physiological condition with a detection limit of 7.5 μM, and was applied to image Cl- in vitro and in vivo successfully.
Collapse
Affiliation(s)
- Fengyuan Zhang
- State Key Laboratory of Applied Organic Chemistry and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China; School of Basic Medical Science, Ningxia Medical University, Yinchuan, 750004, China
| | - Chen Ma
- State Key Laboratory of Applied Organic Chemistry and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| | - Zhijuan Jiao
- State Key Laboratory of Applied Organic Chemistry and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| | - Shuai Mu
- State Key Laboratory of Applied Organic Chemistry and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| | - Yida Zhang
- State Key Laboratory of Applied Organic Chemistry and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| | - Xiaoyan Liu
- State Key Laboratory of Applied Organic Chemistry and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China
| | - Haixia Zhang
- State Key Laboratory of Applied Organic Chemistry and College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou, 730000, China.
| |
Collapse
|
18
|
Yi S, Lu Z, Lin Y, Wang J, Qiao Z, Shen R, Zhang J, Hou L. A novel mitochondria-targeted phosphorescence probe for hypochlorite ions detection in living cells. Talanta 2020; 209:120516. [DOI: 10.1016/j.talanta.2019.120516] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 10/17/2019] [Accepted: 10/26/2019] [Indexed: 11/26/2022]
|
19
|
Jiang D, Xue X, Zhu M, Zhang G, Wang Y, Feng C, Wang Z, Zhao H. Novel Rhodamine-Derivated Dual-Responsive Colorimetric Fluorescent Chemoprobe for the Hypersensitive Detection of Ga3+ and Hg2+ and Biological Imaging. Ind Eng Chem Res 2019. [DOI: 10.1021/acs.iecr.9b03865] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Daoyong Jiang
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Xingying Xue
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Mei Zhu
- Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China
| | - Guoning Zhang
- Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China
| | - Yucheng Wang
- Institute of Medicinal Biotechnology, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100050, China
| | - Chao Feng
- School of Materials and Chemical Engineering, Bengbu University, Bengbu 233030, PR China
| | - Zhifei Wang
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| | - Hong Zhao
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China
| |
Collapse
|