Pertegal V, Riquelme E, Lozano-Serra J, Cañizares P, Rodrigo MA, Sáez C, Lacasa E. Cleaning technologies integrated in duct flows for the inactivation of pathogenic microorganisms in indoor environments: A critical review of recent innovations and future challenges. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2023; 345:118798. [PMID: 37591101 DOI: 10.1016/j.jenvman.2023.118798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/02/2023] [Accepted: 08/09/2023] [Indexed: 08/19/2023]
Abstract
Pathogenic microorganisms are a major concern in indoor environments, particularly in sensitive facilities such as hospitals, due to their potential to cause nosocomial infections. This study evaluates the concentration of airborne bacteria and fungi in the University Hospital Complex of Albacete (Spain), comparing the results with recent literature. Staphylococcus is identified as the most prevalent bacterial genus with a percentage distribution of 35%, while Aspergillus represents the dominant fungal genus at 34%. The lack of high Technology Readiness Levels (TRL 6, TRL 7) for effective indoor air purification requires research efforts to bridge this knowledge gap. A screening of disinfection technologies for pathogenic airborne microorganisms such as bacteria and fungi is conducted. The integration of filtration, irradiation or and (electro)chemical gas treatment systems in duct flows is discussed to enhance the design of the air-conditioning systems for indoor air purification. Concerns over microbial growth have led to recent studies on coating commercial fibrous air filters with antimicrobial particles (silver nanoparticles, iron oxide nanowires) and polymeric materials (polyaniline, polyvinylidene fluoride). Promising alternatives to traditional short-wave UV-C energy for disinfection include LED and Far-UVC irradiation systems. Additionally, research explores the use of TiO2 and TiO2 doped with metals (Ag, Cu, Pt) in filters with photocatalytic properties, enabling the utilization of visible or solar light. Hybrid photocatalysis, combining TiO2 with polymers, carbon nanomaterials, or MXene nanomaterials, enhances the photocatalytic process. Chemical treatment systems such as aerosolization of biocidal agents (benzalkonium chloride, hydrogen peroxide, chlorine dioxide or ozone) with their possible combination with other technologies such as adsorption, filtration or photocatalysis, are also tested for gas disinfection. However, the limited number of studies on the use of electrochemical technology poses a challenge for further investigation into gas-phase oxidant generation, without the formation of harmful by-products, to raise its TRL for effectively inactivating airborne microorganisms in indoor environments.
Collapse
Affiliation(s)
- Víctor Pertegal
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario s/n, 02071, Albacete, Spain
| | - Eva Riquelme
- Clinical Parasitology and Microbiology Area. University Hospital Complex of Albacete, C/ Hermanos Falcó 37, 02006, Albacete, Spain
| | - Julia Lozano-Serra
- Clinical Parasitology and Microbiology Area. University Hospital Complex of Albacete, C/ Hermanos Falcó 37, 02006, Albacete, Spain
| | - Pablo Cañizares
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Manuel A Rodrigo
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Cristina Sáez
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario s/n, 13005, Ciudad Real, Spain
| | - Engracia Lacasa
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario s/n, 02071, Albacete, Spain.
| |
Collapse
|
2
|
Moghadam TT, Ochoa Morales CE, Lopez Zambrano MJ, Bruton K, O'Sullivan DTJ. Energy efficient ventilation and indoor air quality in the context of COVID-19 - A systematic review. RENEWABLE & SUSTAINABLE ENERGY REVIEWS 2023; 182:113356. [PMID: 37220488 PMCID: PMC10186986 DOI: 10.1016/j.rser.2023.113356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 05/02/2023] [Accepted: 05/08/2023] [Indexed: 05/25/2023]
Abstract
New COVID-19 ventilation guidelines have resulted in higher energy consumption to maintain indoor air quality (IAQ), and energy efficiency has become a secondary concern. Despite the significance of the studies conducted on COVID-19 ventilation requirements, a comprehensive investigation of the associated energy challenges has not been discussed. This study aims to present a critical systematic review of the Coronavirus viral spreading risk mitigation through ventilation systems (VS) and its relation to energy use. COVID-19 heating, ventilation and air conditioning (HVAC)-related countermeasures proposed by industry professionals have been reviewed and their influence on operating VS and energy consumption have also been discussed. A critical review analysis was then conducted on publications from 2020 to 2022. Four research questions (RQs) have been selected for this review concerning i) maturity of the existing literature, ii) building types and occupancy profile, iii) ventilation types and effective control strategies and iv) challenges and related causes. The results reveal that employing HVAC auxiliary equipment is mostly effective and increased fresh air supply is the most significant challenge associated with increased energy consumption due to maintaining IAQ. Future studies should focus on novel approaches toward solving the apparently conflicting objectives of minimizing energy consumption and maximizing IAQ. Also, effective ventilation control strategies should be assessed in various buildings with different occupancy densities. The implications of this study can be useful for future development of this topic not only to enhance the energy efficiency of the VS but also to enable more resiliency and health in buildings.
Collapse
Affiliation(s)
- Talie T Moghadam
- Intelligent Efficiency Research Group (IERG), University College Cork, Cork, Ireland
| | | | | | - Ken Bruton
- Intelligent Efficiency Research Group (IERG), University College Cork, Cork, Ireland
| | | |
Collapse
|
3
|
Kang I, McCreery A, Azimi P, Gramigna A, Baca G, Hayes W, Crowder T, Scheu R, Evens A, Stephens B. Impacts of residential indoor air quality and environmental risk factors on adult asthma-related health outcomes in Chicago, IL. JOURNAL OF EXPOSURE SCIENCE & ENVIRONMENTAL EPIDEMIOLOGY 2023; 33:358-367. [PMID: 36450925 DOI: 10.1038/s41370-022-00503-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 11/17/2022] [Accepted: 11/17/2022] [Indexed: 06/03/2023]
Abstract
BACKGROUND Residential environments are known to contribute to asthma. OBJECTIVE To examine the joint impacts of exposures to residential indoor and outdoor air pollutants and housing risk factors on adult asthma-related health outcomes. METHODS We analyzed >1-year of data from 53 participants from 41 homes in the pre-intervention period of the Breathe Easy Project prior to ventilation and filtration retrofits. Health outcomes included surveys of asthma control, health-related quality of life, stress, and healthcare utilizations. Environmental assessments included quarterly measurements of indoor and outdoor pollutants (e.g., HCHO, CO, CO2, NO2, O3, and PM), home walk-throughs, and surveys of environmental risk factors. Indoor pollutant concentrations were also matched with surveys of time spent at home to estimate indoor pollutant exposures. RESULTS Cross-sectional analyses using mixed-effects models indicated that lower annual average asthma control test (ACT) scores were associated (p < 0.05) with higher indoor NO2 (concentration/exposure: β = -2.42/-1.57), indoor temperature (β = -1.03 to -0.94), and mold/dampness (β = -3.09 to -2.41). In longitudinal analysis, lower ACT scores were also associated (p < 0.05) with higher indoor NO2 concentrations (β = -0.29), PM1 (concentration/exposure: β = -0.12/-0.24), PM2.5 (concentration/exposure: β = -0.12/-0.26), and PM10 (concentration/exposure: β = 10.14/-0.28). Emergency department visits were associated with poorer asthma control [incidence rate ratio (IRR) = 0.84; p < 0.001], physical health (IRR = 0.95; p < 0.05), mental health (IRR = 0.95; p < 0.05), higher I/O NO2 ratios (IRR = 1.30; p < 0.05), and higher indoor temperatures (IRR = 1.41; p < 0.05). SIGNIFICANCE Findings suggest that residential risk factors, including indoor air pollution (especially NO2 and particulate matter), higher indoor temperature, and mold/dampness, may contribute to poorer asthma control. IMPACT This study highlights the importance of residential indoor air quality and environmental risk factors for asthma control, health-related quality of life, and emergency department visits for asthma. Two timescales of mixed models suggest that exposure to indoor NO2 and particulate matter, higher indoor temperature, and mold/dampness was associated with poorer asthma control. Additionally, emergency department visits were associated with poorer asthma control and health-related quality of life, as well as higher I/O NO2 ratios and indoor temperatures. These findings deepen our understanding of the interrelationships between housing, air quality, and health, and have important implications for programs and policy.
Collapse
Affiliation(s)
- Insung Kang
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA
| | | | - Parham Azimi
- Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA, USA
| | | | | | | | | | | | | | - Brent Stephens
- Department of Civil, Architectural, and Environmental Engineering, Illinois Institute of Technology, Chicago, IL, USA.
| |
Collapse
|
4
|
Wang J, Du W, Lei Y, Chen Y, Wang Z, Mao K, Tao S, Pan B. Quantifying the dynamic characteristics of indoor air pollution using real-time sensors: Current status and future implication. ENVIRONMENT INTERNATIONAL 2023; 175:107934. [PMID: 37086491 DOI: 10.1016/j.envint.2023.107934] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 04/12/2023] [Accepted: 04/12/2023] [Indexed: 05/03/2023]
Abstract
People generally spend most of their time indoors, making indoor air quality be of great significance to human health. Large spatiotemporal heterogeneity of indoor air pollution can be hardly captured by conventional filter-based monitoring but real-time monitoring. Real-time monitoring is conducive to change air assessment mode from static and sparse analysis to dynamic and massive analysis, and has made remarkable strides in indoor air evaluation. In this review, the state of art, strengths, challenges, and further development of real-time sensors used in indoor air evaluation are focused on. Researches using real-time sensors for indoor air evaluation have increased rapidly since 2018, and are mainly conducted in China and the USA, with the most frequently investigated air pollutants of PM2.5. In addition to high spatiotemporal resolution, real-time sensors for indoor air evaluation have prominent advantages in 3-dimensional monitoring, pollution peak and source identification, and short-term health effect evaluation. Huge amounts of data from real-time sensors also facilitate the modeling and prediction of indoor air pollution. However, challenges still remain in extensive deployment of real-time sensors indoors, including the selection, performance, stability, as well as calibration of sensors. In future, sensors with high performance, long-term stability, low price, and low energy consumption are welcomed. Furthermore, more target air pollutants are also expected to be detected simultaneously by real-time sensors in indoor air monitoring.
Collapse
Affiliation(s)
- Jinze Wang
- Key Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871, China
| | - Wei Du
- Yunnan Provincial Key Laboratory of Soil Carbon Sequestration and Pollution Control, Faculty of Environmental Science & Engineering, Kunming University of Science & Technology, Kunming 650500, China.
| | - Yali Lei
- Key Laboratory of Geographic Information Science of the Ministry of Education, School of Geographic Sciences, East China Normal University, Shanghai 200241, China
| | - Yuanchen Chen
- Key Laboratory of Microbial Technology for Industrial Pollution Control of Zhejiang Province, College of Environment, Zhejiang University of Technology, Hangzhou, Zhejiang 310032, China
| | - Zhenglu Wang
- West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, China
| | - Kang Mao
- State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang, China
| | - Shu Tao
- Key Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences, Peking University, Beijing 100871, China
| | - Bo Pan
- Yunnan Provincial Key Laboratory of Soil Carbon Sequestration and Pollution Control, Faculty of Environmental Science & Engineering, Kunming University of Science & Technology, Kunming 650500, China
| |
Collapse
|
5
|
Assessment of ANN Algorithms for the Concentration Prediction of Indoor Air Pollutants in Child Daycare Centers. ENERGIES 2022. [DOI: 10.3390/en15072654] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
As the time spent by people indoors continues to significantly increase, much attention has been paid to indoor air quality. While many IAQ studies have been conducted through field measurements, the use of data-driven techniques such as machine learning has been increasingly used for the prediction of indoor air pollutants. For the present study, the concentrations of indoor air pollutants such as CO2, PM2.5, and VOCs in child daycare centers were predicted by using an artificial neural network model with three different training algorithms including Levenberg–Marquardt, Bayesian regularization, and Broyden–Fletcher–Goldfarb–Shanno quasi-Newton methods. For training and validation, data of indoor pollutants measured in child daycare facilities over a 1-month period were used. The results showed all the models produced a good performance for the prediction of indoor pollutants compared with the measured data. Among the models, the prediction by the LM model met the acceptable criteria of ASHRAE guideline 14 under all conditions. It was observed that the prediction performance decreased as the number of hidden layers increased. Moreover, the prediction performance was differed by the type of indoor pollutant. This was caused by patterns observed in the measured data. Considering the outcomes of the study, better prediction results can be obtained through the selection of suitable prediction models for time series data as well as the adjustment of training algorithms.
Collapse
|