1
|
Zhang Y, Hou Z, Si C, Han G, Zhao Y, Lu X, Liu J, Ning J, Yang F. Effects of Mask Material on Lateral Undercut of Silicon Dry Etching. MICROMACHINES 2023; 14:306. [PMID: 36838006 PMCID: PMC9966973 DOI: 10.3390/mi14020306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Revised: 01/17/2023] [Accepted: 01/20/2023] [Indexed: 06/18/2023]
Abstract
The silicon etching process is a core component of production in the semiconductor industry. Undercut is a nonideal effect in silicon dry etching. A reduced undercut is desired when preparing structures that demand a good sidewall morphology, while an enlarged undercut is conducive to the fabrication of microstructure tips. Undercut is related to not only the production parameters but also the mask materials. In this study, five mask materials-Cr, Al, ITO, SiNx, and SiO2-are chosen to compare the undercut effect caused by the isotropic etching process and the Bosch process. In the Bosch process, the SiNx mask causes the largest undercut, and the SiO2 mask causes the smallest undercut. In the isotropic process, the results are reversed. The effect of charges in the mask layer is found to produce this result, and the effect of electrons accumulating during the process is found to be negligible. The undercut effect can be enhanced or suppressed by selecting appropriate mask materials, which is helpful in the MEMS process. Finally, using an Al mask, a tapered silicon tip with a top diameter of 119.3 nm is fabricated using the isotropic etching process.
Collapse
Affiliation(s)
- Yongkang Zhang
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | - Zhongxuan Hou
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | - Chaowei Si
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | - Guowei Han
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | - Yongmei Zhao
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100083, China
| | - Xiaorui Lu
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | - Jiahui Liu
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | - Jin Ning
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- School of Electronic, Electrical and Communication Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100083, China
| | - Fuhua Yang
- Engineering Research Center for Semiconductor Integrated Technology, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| |
Collapse
|
2
|
Dusad LK, Sharma R. Role of Silver Catalyst in Synthesis of Porous Silicon and Vertically Aligned Nanostructures with High Aspect Ratio without Using Lithography. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A 2022. [DOI: 10.1134/s0036024422140072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
3
|
Mamun AA, Zhao F. In-Plane Si Microneedles: Fabrication, Characterization, Modeling and Applications. MICROMACHINES 2022; 13:657. [PMID: 35630124 PMCID: PMC9146885 DOI: 10.3390/mi13050657] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 04/16/2022] [Accepted: 04/17/2022] [Indexed: 01/26/2023]
Abstract
Microneedles are getting more and more attention in research and commercialization since their advancement in the 1990s due to the advantages over traditional hypodermic needles such as minimum invasiveness, low material and fabrication cost, and precise needle geometry control, etc. The design and fabrication of microneedles depend on various factors such as the type of materials used, fabrication planes and techniques, needle structures, etc. In the past years, in-plane and out-of-plane microneedle technologies made by silicon (Si), polymer, metal, and other materials have been developed for numerous biomedical applications including drug delivery, sample collections, medical diagnostics, and bio-sensing. Among these microneedle technologies, in-plane Si microneedles excel by the inherent properties of Si such as mechanical strength, wear resistance, biocompatibility, and structural advantages of in-plane configuration such as a wide range of length, readiness of integration with other supporting components, and complementary metal-oxide-semiconductor (CMOS) compatible fabrication. This article aims to provide a review of in-plane Si microneedles with a focus on fabrication techniques, theoretical and numerical analysis, experimental characterization of structural and fluidic behaviors, major applications, potential challenges, and future prospects.
Collapse
Affiliation(s)
| | - Feng Zhao
- Micro/Nanoelectronics and Energy Laboratory, School of Engineering and Computer Science, Washington State University, Vancouver, WA 98686, USA;
| |
Collapse
|
4
|
Roh H, Yoon YJ, Park JS, Kang DH, Kwak SM, Lee BC, Im M. Fabrication of High-Density Out-of-Plane Microneedle Arrays with Various Heights and Diverse Cross-Sectional Shapes. NANO-MICRO LETTERS 2021; 14:24. [PMID: 34888758 PMCID: PMC8656445 DOI: 10.1007/s40820-021-00778-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Accepted: 11/16/2021] [Indexed: 06/01/2023]
Abstract
Out-of-plane microneedle structures are widely used in various applications such as transcutaneous drug delivery and neural signal recording for brain machine interface. This work presents a novel but simple method to fabricate high-density silicon (Si) microneedle arrays with various heights and diverse cross-sectional shapes depending on photomask pattern designs. The proposed fabrication method is composed of a single photolithography and two subsequent deep reactive ion etching (DRIE) steps. First, a photoresist layer was patterned on a Si substrate to define areas to be etched, which will eventually determine the final location and shape of each individual microneedle. Then, the 1st DRIE step created deep trenches with a highly anisotropic etching of the Si substrate. Subsequently, the photoresist was removed for more isotropic etching; the 2nd DRIE isolated and sharpened microneedles from the predefined trench structures. Depending on diverse photomask designs, the 2nd DRIE formed arrays of microneedles that have various height distributions, as well as diverse cross-sectional shapes across the substrate. With these simple steps, high-aspect ratio microneedles were created in the high density of up to 625 microneedles mm-2 on a Si wafer. Insertion tests showed a small force as low as ~ 172 µN/microneedle is required for microneedle arrays to penetrate the dura mater of a mouse brain. To demonstrate a feasibility of drug delivery application, we also implemented silk microneedle arrays using molding processes. The fabrication method of the present study is expected to be broadly applicable to create microneedle structures for drug delivery, neuroprosthetic devices, and so on.
Collapse
Affiliation(s)
- Hyeonhee Roh
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
- Division of Electrical Engineering, College of Engineering, Korea University, Seoul, 02841, South Korea
| | - Young Jun Yoon
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
| | - Jin Soo Park
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
- Division of Electrical Engineering, College of Engineering, Korea University, Seoul, 02841, South Korea
| | - Dong-Hyun Kang
- Micro/Nano Fabrication Center, KIST, Seoul, 02792, South Korea
| | - Seung Min Kwak
- Micro/Nano Fabrication Center, KIST, Seoul, 02792, South Korea
| | - Byung Chul Lee
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea
| | - Maesoon Im
- Brain Science Institute, Korea Institute of Science and Technology (KIST), Seoul, 02792, South Korea.
- Division of Bio-Medical Science & Technology, KIST School, University of Science & Technology (UST), Seoul, 02792, South Korea.
| |
Collapse
|
5
|
Batch Fabrication of Silicon Nanometer Tip Using Isotropic Inductively Coupled Plasma Etching. MICROMACHINES 2020; 11:mi11070638. [PMID: 32610624 PMCID: PMC7408416 DOI: 10.3390/mi11070638] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 06/23/2020] [Accepted: 06/27/2020] [Indexed: 11/16/2022]
Abstract
This work reports a batch fabrication process for silicon nanometer tip based on isotropic inductively coupled plasma (ICP) etching technology. The silicon tips with nanometer apex and small surface roughness are produced at wafer-level with good etching homogeneity and repeatability. An ICP etching routine is developed to make silicon tips with apex radius less than 5 nm, aspect ratio greater than 5 at a tip height of 200 nm, and tip height more than 10 μm, and high fabrication yield is achieved by mask compensation and precisely controlling lateral etch depth, which is significant for large-scale manufacturing.
Collapse
|
6
|
Shah AR, Khan MS, Hirahara AM, Lange M, Ranjan R, Dosdall DJ. In Vitro/Ex Vivo Investigation of Modified Utah Electrode Array to Selectively Sense and Pace the Sub-Surface Cardiac His Bundle. ACS Biomater Sci Eng 2020; 6:3335-3348. [PMID: 32715084 DOI: 10.1021/acsbiomaterials.0c00065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Utah Electrode Arrays (UEAs) have previously been characterized and implanted for neural recordings and stimulation at relatively low current levels. This proof-of-concept study investigated the applicability of UEAs in sub-surface cardiac pacing, for the first time, particularly to selectively sense and pace the His-Bundle (HB). HB pacing produces synchronous ventricular depolarization and improved cardiac function. Modified UEAs with sputtered iridium oxide film (SIROF) tips (100 - 150 μm) were characterized for SIROF delamination using an electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), and voltage transient (VT) techniques at various current levels of up to 8 mA for a biphasic pulse with 1 ms duration per phase at 4 Hz. Our results indicate that at a short pacing duration of 20 s with current levels of up to 4 mA, the SIROF exhibited a strong charge-transfer performance. For the longer pacing duration (6 min), SIROF demonstrated its holding capacity at all current levels except for ≥2 mA when delamination commenced for the time exceeded 4 min (EIS) and 2 min (VT). UEAs were inserted in isolated, perfused goat hearts to record the HB electrograms in real-time. Both stimulated and unstimulated electrodes were characterized for SIROF delamination before, during and after in vivo work. Our findings indicate that UEA was stable during the heart's contraction and relaxation phase. Further, at a short pacing duration with current levels of up to 4 mA, UEA demonstrated high selectively in sensing the HB. This proof-of-concept work demonstrates the potential applicability of UEAs in cardiac applications.
Collapse
Affiliation(s)
- Ankur R Shah
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Muhammad S Khan
- Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Annie M Hirahara
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Matthias Lange
- Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA
| | - Ravi Ranjan
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA.,Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Utah, Salt Lake City, UT 84112, USA
| | - Derek J Dosdall
- Department of Biomedical Engineering, The University of Utah, Salt Lake City, UT 84112, USA.,Nora Eccles Harrison Cardiovascular Research and Training Institute, The University of Utah, Salt Lake City, UT 84112, USA.,Division of Cardiovascular Medicine, Department of Internal Medicine, The University of Utah, Salt Lake City, UT 84112, USA.,Division of Cardiothoracic Surgery, Department of Surgery, The University of Utah, Salt Lake City, UT 84112, USA
| |
Collapse
|
7
|
Characterization of Parylene-C degradation mechanisms: In vitro reactive accelerated aging model compared to multiyear in vivo implantation. Biomaterials 2020; 232:119731. [DOI: 10.1016/j.biomaterials.2019.119731] [Citation(s) in RCA: 39] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Revised: 12/19/2019] [Accepted: 12/25/2019] [Indexed: 11/23/2022]
|
8
|
Sigurdsson SA, Yu Z, Lee J, Nurmikko A. A method for large-scale implantation of 3D microdevice ensembles into brain and soft tissue. MICROSYSTEMS & NANOENGINEERING 2020; 6:97. [PMID: 34567706 PMCID: PMC8433454 DOI: 10.1038/s41378-020-00210-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Revised: 07/11/2020] [Accepted: 08/07/2020] [Indexed: 05/16/2023]
Abstract
Wireless networks of implantable electronic sensors and actuators at the microscale (sub-mm) level are being explored for monitoring and modulation of physiological activity for medical diagnostics and therapeutic purposes. Beyond the requirement of integrating multiple electronic or chemical functions within small device volumes, a key challenge is the development of high-throughput methods for the implantation of large numbers of microdevices into soft tissues with minimal damage. To that end, we have developed a method for high-throughput implantation of ~100-200 µm size devices, which are here simulated by proxy microparticle ensembles. While generally applicable to subdermal tissue, our main focus and experimental testbed is the implantation of microparticles into the brain. The method deploys a scalable delivery tool composed of a 2-dimensional array of polyethylene glycol-tipped microneedles that confine the microparticle payloads. Upon dissolution of the bioresorbable polyethylene glycol, the supporting array structure is retrieved, and the microparticles remain embedded in the tissue, distributed spatially and geometrically according to the design of the microfabricated delivery tool. We first evaluated the method in an agarose testbed in terms of spatial precision and throughput for up to 1000 passive spherical and planar microparticles acting as proxy devices. We then performed the same evaluations by implanting particles into the rat cortex under acute conditions and assessed the tissue injury produced by our method of implantation under chronic conditions.
Collapse
Affiliation(s)
| | - Zeyang Yu
- Department of Neurology, Massachusetts General Hospital, Boston, MA 02114 USA
| | - Joonhee Lee
- Department of Physics and Astronomy, West Virginia University, Morgantown, WV 26506 USA
- Department of Neuroscience, West Virginia University, Morgantown, WV 26506 USA
| | - Arto Nurmikko
- School of Engineering, Brown University, Providence, RI 02912 USA
| |
Collapse
|
9
|
Li Y, Zhang H, Yang R, Laffitte Y, Schmill U, Hu W, Kaddoura M, Blondeel EJM, Cui B. Fabrication of sharp silicon hollow microneedles by deep-reactive ion etching towards minimally invasive diagnostics. MICROSYSTEMS & NANOENGINEERING 2019; 5:41. [PMID: 31636931 PMCID: PMC6799813 DOI: 10.1038/s41378-019-0077-y] [Citation(s) in RCA: 83] [Impact Index Per Article: 16.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 04/10/2019] [Accepted: 04/12/2019] [Indexed: 05/22/2023]
Abstract
Microneedle technologies have the potential for expanding the capabilities of wearable health monitoring from physiology to biochemistry. This paper presents the fabrication of silicon hollow microneedles by a deep-reactive ion etching (DRIE) process, with the aim of exploring the feasibility of microneedle-based in-vivo monitoring of biomarkers in skin fluid. Such devices shall have the ability to allow the sensing elements to be integrated either within the needle borehole or on the backside of the device, relying on capillary filling of the borehole with dermal interstitial fluid (ISF) for transporting clinically relevant biomarkers to the sensor sites. The modified DRIE process was utilized for the anisotropic etching of circular holes with diameters as small as 30 μm to a depth of >300 μm by enhancing ion bombardment to efficiently remove the fluorocarbon passivation polymer. Afterward, isotropic wet and/or dry etching was utilized to sharpen the needle due to faster etching at the pillar top, achieving tip radii as small as 5 μm. Such sharp microneedles have been demonstrated to be sufficiently robust to penetrate porcine skin without needing any aids such as an impact-insertion applicator, with the needles remaining mechanically intact after repetitive penetrations. The capillary filling of DRIE-etched through-wafer holes with water has also been demonstrated, showing the feasibility of use to transport the analyte to the target sites.
Collapse
Affiliation(s)
- Yan Li
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1 Canada
- ExVivo Labs Inc., 3 Regina Street North, Waterloo, ON N2J 2Z7 Canada
| | - Hang Zhang
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1 Canada
| | - Ruifeng Yang
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1 Canada
| | - Yohan Laffitte
- ExVivo Labs Inc., 3 Regina Street North, Waterloo, ON N2J 2Z7 Canada
| | - Ulises Schmill
- ExVivo Labs Inc., 3 Regina Street North, Waterloo, ON N2J 2Z7 Canada
| | - Wenhan Hu
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1 Canada
| | - Moufeed Kaddoura
- ExVivo Labs Inc., 3 Regina Street North, Waterloo, ON N2J 2Z7 Canada
| | | | - Bo Cui
- Department of Electrical and Computer Engineering, University of Waterloo, 200 University Avenue West, Waterloo, ON N2L 3G1 Canada
| |
Collapse
|
10
|
Joshi-Imre A, Black BJ, Abbott J, Kanneganti A, Rihani R, Chakraborty B, Danda VR, Maeng J, Sharma R, Rieth L, Negi S, Pancrazio JJ, Cogan SF. Chronic recording and electrochemical performance of amorphous silicon carbide-coated Utah electrode arrays implanted in rat motor cortex. J Neural Eng 2019; 16:046006. [DOI: 10.1088/1741-2552/ab1bc8] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
11
|
Straka MM, Shafer B, Vasudevan S, Welle C, Rieth L. Characterizing Longitudinal Changes in the Impedance Spectra of In-Vivo Peripheral Nerve Electrodes. MICROMACHINES 2018; 9:mi9110587. [PMID: 30424513 PMCID: PMC6266965 DOI: 10.3390/mi9110587] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2018] [Revised: 11/02/2018] [Accepted: 11/05/2018] [Indexed: 12/18/2022]
Abstract
Characterizing the aging processes of electrodes in vivo is essential in order to elucidate the changes of the electrode–tissue interface and the device. However, commonly used impedance measurements at 1 kHz are insufficient for determining electrode viability, with measurements being prone to false positives. We implanted cohorts of five iridium oxide (IrOx) and six platinum (Pt) Utah arrays into the sciatic nerve of rats, and collected the electrochemical impedance spectroscopy (EIS) up to 12 weeks or until array failure. We developed a method to classify the shapes of the magnitude and phase spectra, and correlated the classifications to circuit models and electrochemical processes at the interface likely responsible. We found categories of EIS characteristic of iridium oxide tip metallization, platinum tip metallization, tip metal degradation, encapsulation degradation, and wire breakage in the lead. We also fitted the impedance spectra as features to a fine-Gaussian support vector machine (SVM) algorithm for both IrOx and Pt tipped arrays, with a prediction accuracy for categories of 95% and 99%, respectively. Together, this suggests that these simple and computationally efficient algorithms are sufficient to explain the majority of variance across a wide range of EIS data describing Utah arrays. These categories were assessed over time, providing insights into the degradation and failure mechanisms for both the electrode–tissue interface and wire bundle. Methods developed in this study will allow for a better understanding of how EIS can characterize the physical changes to electrodes in vivo.
Collapse
Affiliation(s)
- Malgorzata M Straka
- Center for Bioelectronic Medicine, Feinstein Institute for Medical Research, Northwell Health, Manhasset, NY 11030, USA.
| | - Benjamin Shafer
- U.S. Food and Drug Administration, Center for Devices and Radiological Health (CDRH), Office of Science and Engineering Laboratory (OSEL), Division of Biomedical Physics (DBP), Silver Spring, MD 20993, USA.
| | - Srikanth Vasudevan
- U.S. Food and Drug Administration, Center for Devices and Radiological Health (CDRH), Office of Science and Engineering Laboratory (OSEL), Division of Biomedical Physics (DBP), Silver Spring, MD 20993, USA.
| | - Cristin Welle
- Departments of Neurosurgery and Bioengineering, University of Colorado, Aurora, CO 80045, USA.
| | - Loren Rieth
- Center for Bioelectronic Medicine, Feinstein Institute for Medical Research, Northwell Health, Manhasset, NY 11030, USA.
- Departments of Electrical Engineering and Bioengineering, University of Utah, Salt Lake City, UT 84112, USA.
| |
Collapse
|
12
|
Preparation, properties and challenges of the microneedles-based insulin delivery system. J Control Release 2018; 288:173-188. [PMID: 30189223 DOI: 10.1016/j.jconrel.2018.08.042] [Citation(s) in RCA: 78] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 08/30/2018] [Accepted: 08/31/2018] [Indexed: 12/13/2022]
Abstract
Microneedle technology relates to pharmacy, polymer chemistry and micromachining. Microneedle can effectively deliver insulin into systemic circulation across the skin. This process does not affect the activity of insulin. Compared to subcutaneous injection, microneedles cause less pain for their special structure. This review thoroughly discusses the preparation technologies of the microneedles-based insulin delivery system including solid, hollow, dissolving, phase transition, glucose-responsive microneedle patches. In the meantime, the properties, challenges and clinical/commercial status of the microneedles-based insulin delivery system are also discussed in this review.
Collapse
|
13
|
Caldwell R, Mandal H, Sharma R, Solzbacher F, Tathireddy P, Rieth L. Analysis of Al 2O 3-parylene C bilayer coatings and impact of microelectrode topography on long term stability of implantable neural arrays. J Neural Eng 2018; 14:046011. [PMID: 28351998 DOI: 10.1088/1741-2552/aa69d3] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Performance of many dielectric coatings for neural electrodes degrades over time, contributing to loss of neural signals and evoked percepts. Studies using planar test substrates have found that a novel bilayer coating of atomic-layer deposited (ALD) Al2O3 and parylene C is a promising candidate for neural electrode applications, exhibiting superior stability to parylene C alone. However, initial results from bilayer encapsulation testing on non-planar devices have been less positive. Our aim was to evaluate ALD Al2O3-parylene C coatings using novel test paradigms, to rigorously evaluate dielectric coatings for neural electrode applications by incorporating neural electrode topography into test structure design. APPROACH Five test devices incorporated three distinct topographical features common to neural electrodes, derived from the utah electrode array (UEA). Devices with bilayer (52 nm Al2O3 + 6 µm parylene C) were evaluated against parylene C controls (N ⩾ 6 per device type). Devices were aged in phosphate buffered saline at 67 °C for up to 311 d, and monitored through: (1) leakage current to evaluate encapsulation lifetimes (>1 nA during 5VDC bias indicated failure), and (2) wideband (1-105 Hz) impedance. MAIN RESULTS Mean-times-to-failure (MTTFs) ranged from 12 to 506 d for bilayer-coated devices, versus 10 to >2310 d for controls. Statistical testing (log-rank test, α = 0.05) of failure rates gave mixed results but favored the control condition. After failure, impedance loss for bilayer devices continued for months and manifested across the entire spectrum, whereas the effect was self-limiting after several days, and restricted to frequencies <100 Hz for controls. These results correlated well with observations of UEAs encapsulated with bilayer and control films. SIGNIFICANCE We observed encapsulation failure modes and behaviors comparable to neural electrode performance which were undetected in studies with planar test devices. We found the impact of parylene C defects to be exacerbated by ALD Al2O3, and conclude that inferior bilayer performance arises from degradation of ALD Al2O3 when directly exposed to saline. This is an important consideration, given that neural electrodes with bilayer coatings are expected to have ALD Al2O3 exposed at dielectric boundaries that delineate electrode sites. Process improvements and use of different inorganic coatings to decrease dissolution in physiological fluids may improve performance. Testing frameworks which take neural electrode complexities into account will be well suited to reliably evaluate such encapsulation schemes.
Collapse
Affiliation(s)
- Ryan Caldwell
- Department of Bioengineering, University of Utah, Salt Lake City, UT, United States of America
| | | | | | | | | | | |
Collapse
|
14
|
Chen G, Dodson B, Hedges DM, Steffensen SC, Harb JN, Puleo C, Galligan C, Ashe J, Vanfleet RR, Davis RC. Fabrication of High Aspect Ratio Millimeter-Tall Free-Standing Carbon Nanotube-Based Microelectrode Arrays. ACS Biomater Sci Eng 2018; 4:1900-1907. [PMID: 33445345 DOI: 10.1021/acsbiomaterials.8b00038] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Microelectrode arrays of carbon nanotube (CNT)/carbon composite posts with high aspect ratio and millimeter-length were fabricated using carbon-nanotube-templated microfabrication with a sacrificial "hedge". The high aspect ratio, mechanical robustness, and electrical conductivity of these electrodes make them a potential candidate for next-generation neural interfacing. Electrochemical measurements were also demonstrated using an individual CNT post microelectrode with a diameter of 25 μm and a length of 1 mm to perform cyclic voltammetry on both methyl viologen and dopamine in a phosphate-buffered saline solution. In addition to detection of the characteristic peaks, the CNT post microelectrodes show a fast electrochemical response, which may be enabling for in vivo and/or in vitro measurements. The CNT post electrode fabrication process was also integrated with other microfabrication techniques, resulting in individually addressable electrodes.
Collapse
Affiliation(s)
- Guohai Chen
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| | - Berg Dodson
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| | - David M Hedges
- Department of Psychology and Neuroscience, Brigham Young University, Provo, Utah 84602, United States
| | - Scott C Steffensen
- Department of Psychology and Neuroscience, Brigham Young University, Provo, Utah 84602, United States
| | - John N Harb
- Department of Chemical Engineering, Brigham Young University, Provo, Utah 84602, United States
| | - Chris Puleo
- General Electric Global Research (GE-GR), 1 Research Circle, Niskayuna, New York 12309, United States
| | - Craig Galligan
- General Electric Global Research (GE-GR), 1 Research Circle, Niskayuna, New York 12309, United States
| | - Jeffrey Ashe
- General Electric Global Research (GE-GR), 1 Research Circle, Niskayuna, New York 12309, United States
| | - Richard R Vanfleet
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| | - Robert C Davis
- Department of Physics and Astronomy, Brigham Young University, Provo, Utah 84602, United States
| |
Collapse
|
15
|
Prospects for a Robust Cortical Recording Interface. Neuromodulation 2018. [DOI: 10.1016/b978-0-12-805353-9.00028-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
16
|
Caldwell R, Sharma R, Takmakov P, Street MG, Solzbacher F, Tathireddy P, Rieth L. Neural electrode resilience against dielectric damage may be improved by use of highly doped silicon as a conductive material. J Neurosci Methods 2018; 293:210-225. [DOI: 10.1016/j.jneumeth.2017.10.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 10/01/2017] [Accepted: 10/02/2017] [Indexed: 11/28/2022]
|
17
|
Szostak KM, Grand L, Constandinou TG. Neural Interfaces for Intracortical Recording: Requirements, Fabrication Methods, and Characteristics. Front Neurosci 2017; 11:665. [PMID: 29270103 PMCID: PMC5725438 DOI: 10.3389/fnins.2017.00665] [Citation(s) in RCA: 74] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Accepted: 11/15/2017] [Indexed: 01/30/2023] Open
Abstract
Implantable neural interfaces for central nervous system research have been designed with wire, polymer, or micromachining technologies over the past 70 years. Research on biocompatible materials, ideal probe shapes, and insertion methods has resulted in building more and more capable neural interfaces. Although the trend is promising, the long-term reliability of such devices has not yet met the required criteria for chronic human application. The performance of neural interfaces in chronic settings often degrades due to foreign body response to the implant that is initiated by the surgical procedure, and related to the probe structure, and material properties used in fabricating the neural interface. In this review, we identify the key requirements for neural interfaces for intracortical recording, describe the three different types of probes-microwire, micromachined, and polymer-based probes; their materials, fabrication methods, and discuss their characteristics and related challenges.
Collapse
Affiliation(s)
- Katarzyna M. Szostak
- Next Generation Neural Interfaces Lab, Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Imperial College London, London, United Kingdom
| | - Laszlo Grand
- Next Generation Neural Interfaces Lab, Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Imperial College London, London, United Kingdom
- Department of Neurology and Neurosurgery, Johns Hopkins University, Baltimore, MD, United States
| | - Timothy G. Constandinou
- Next Generation Neural Interfaces Lab, Department of Electrical and Electronic Engineering, Centre for Bio-Inspired Technology, Imperial College London, London, United Kingdom
| |
Collapse
|
18
|
Ghane-Motlagh B, Javanbakht T, Shoghi F, Wilkinson KJ, Martel R, Sawan M. Physicochemical properties of peptide-coated microelectrode arrays and their in vitro effects on neuroblast cells. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 68:642-650. [DOI: 10.1016/j.msec.2016.06.045] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 05/25/2016] [Accepted: 06/13/2016] [Indexed: 11/25/2022]
|
19
|
Ghane Motlagh B, Choueib M, Hajhosseini Mesgar A, Hasanuzzaman M, Sawan M. Direct Growth of Carbon Nanotubes on New High-Density 3D Pyramid-Shaped Microelectrode Arrays for Brain-Machine Interfaces. MICROMACHINES 2016; 7:mi7090163. [PMID: 30404335 PMCID: PMC6189795 DOI: 10.3390/mi7090163] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 08/26/2016] [Accepted: 08/30/2016] [Indexed: 11/29/2022]
Abstract
Silicon micromachined, high-density, pyramid-shaped neural microelectrode arrays (MEAs) have been designed and fabricated for intracortical 3D recording and stimulation. The novel architecture of this MEA has made it unique among the currently available micromachined electrode arrays, as it has provided higher density contacts between the electrodes and targeted neural tissue facilitating recording from different depths of the brain. Our novel masking technique enhances uniform tip-exposure for variable-height electrodes and improves process time and cost significantly. The tips of the electrodes have been coated with platinum (Pt). We have reported for the first time a selective direct growth of carbon nanotubes (CNTs) on the tips of 3D MEAs using the Pt coating as a catalyzer. The average impedance of the CNT-coated electrodes at 1 kHz is 14 kΩ. The CNT coating led to a 5-fold decrease of the impedance and a 600-fold increase in charge transfer compared with the Pt electrode.
Collapse
Affiliation(s)
- Bahareh Ghane Motlagh
- Polystim Neurotechnologies Laboratory, Department of Electrical Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada.
| | - May Choueib
- Institut Lumière Matière, Université Claude Bernard Lyon 1, CNRS, Univ Lyon, Villeurbanne 69622, France.
| | - Alireza Hajhosseini Mesgar
- Microfabrication Laboratory (LMF), Thin Films Group (GCM), Department of Engineering Physics, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada.
| | - Md Hasanuzzaman
- Polystim Neurotechnologies Laboratory, Department of Electrical Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada.
| | - Mohamad Sawan
- Polystim Neurotechnologies Laboratory, Department of Electrical Engineering, Polytechnique Montreal, Montreal, QC H3C 3A7, Canada.
| |
Collapse
|
20
|
Deng Y, Chen J, Zhao Y, Yan X, Zhang L, Choy K, Hu J, Sant HJ, Gale BK, Tang T. Transdermal Delivery of siRNA through Microneedle Array. Sci Rep 2016; 6:21422. [PMID: 26888011 PMCID: PMC4757825 DOI: 10.1038/srep21422] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Accepted: 01/22/2016] [Indexed: 01/07/2023] Open
Abstract
Successful development of siRNA therapies has significant potential for the treatment of skin conditions (alopecia, allergic skin diseases, hyperpigmentation, psoriasis, skin cancer, pachyonychia congenital) caused by aberrant gene expression. Although hypodermic needles can be used to effectively deliver siRNA through the stratum corneum, the major challenge is that this approach is painful and the effects are restricted to the injection site. Microneedle arrays may represent a better way to deliver siRNAs across the stratum corneum. In this study, we evaluated for the first time the ability of the solid silicon microneedle array for punching holes to deliver cholesterol-modified housekeeping gene (Gapdh) siRNA to the mouse ear skin. Treating the ear with microneedles showed permeation of siRNA in the skin and could reduce Gapdh gene expression up to 66% in the skin without accumulation in the major organs. The results showed that microneedle arrays could effectively deliver siRNA to relevant regions of the skin noninvasively.
Collapse
Affiliation(s)
- Yan Deng
- Department of Obstetrics &Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China.,Shenzhen Research Institute, The Chinese University of Hong Kong, China
| | - Jiao Chen
- Department of Obstetrics &Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China.,Shenzhen Research Institute, The Chinese University of Hong Kong, China
| | - Yi Zhao
- Department of Obstetrics &Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Xiaohui Yan
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China
| | - Li Zhang
- Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China.,Chow Yuk Ho Technology Centre for Innovative Medicine, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Kwongwai Choy
- Department of Obstetrics &Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China.,Shenzhen Research Institute, The Chinese University of Hong Kong, China
| | - Jun Hu
- Peking University Shenzhen Hospital, Shenzhen, China
| | - Himanshu J Sant
- State of Utah Centre of Excellence for Biomedical Microfluidics, Departments of Bioengineering and Mechanical Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | - Bruce K Gale
- State of Utah Centre of Excellence for Biomedical Microfluidics, Departments of Bioengineering and Mechanical Engineering, University of Utah, Salt Lake City, UT 84112, USA
| | - Tao Tang
- Department of Obstetrics &Gynaecology, Faculty of Medicine, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong, China.,Shenzhen Research Institute, The Chinese University of Hong Kong, China
| |
Collapse
|
21
|
Xie X, Rieth L, Caldwell R, Negi S, Bhandari R, Sharma R, Tathireddy P, Solzbacher F. Effect of bias voltage and temperature on lifetime of wireless neural interfaces with Al ₂O₃ and parylene bilayer encapsulation. Biomed Microdevices 2015; 17:1. [PMID: 25653054 DOI: 10.1007/s10544-014-9904-y] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The lifetime of neural interfaces is a critical challenge for chronic implantations, as therapeutic devices (e.g., neural prosthetics) will require decades of lifetime. We evaluated the lifetime of wireless Utah electrode array (UEA) based neural interfaces with a bilayer encapsulation scheme utilizing a combination of alumina deposited by Atomic Layer Deposition (ALD) and parylene C. Wireless integrated neural interfaces (INIs), equipped with recording version 9 (INI-R9) ASIC chips, were used to monitor the encapsulation performance through radio-frequency (RF) power and telemetry. The wireless devices were encapsulated with 52 nm of ALD Al2O3 and 6 μm of parylene C, and tested by soaking in phosphate buffered solution (PBS) at 57 °C for 4× accelerated lifetime testing. The INIs were also powered continuously through 2.765 MHz inductive power and forward telemetry link at unregulated 5 V. The bilayer encapsulated INIs were fully functional for ∼35 days (140 days at 37 °C equivalent) with consistent power-up frequencies (∼910 MHz), stable RF signal (∼-75 dBm), and 100 % command reception rate. This is ∼10 times of equivalent lifetime of INIs with parylene-only encapsulation (13 days) under same power condition at 37 °C. The bilayer coated INIs without continuous powering lasted over 1860 equivalent days (still working) at 37 °C. Those results suggest that bias stress is a significant factor to accelerate the failure of the encapsulated devices. The INIs failed completely within 5 days of the initial frequency shift of RF signal at 57 °C, which implied that the RF frequency shift is an early indicator of encapsulation/device failure.
Collapse
|
22
|
Jorfi M, Skousen JL, Weder C, Capadona JR. Progress towards biocompatible intracortical microelectrodes for neural interfacing applications. J Neural Eng 2014; 12:011001. [PMID: 25460808 DOI: 10.1088/1741-2560/12/1/011001] [Citation(s) in RCA: 217] [Impact Index Per Article: 21.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
To ensure long-term consistent neural recordings, next-generation intracortical microelectrodes are being developed with an increased emphasis on reducing the neuro-inflammatory response. The increased emphasis stems from the improved understanding of the multifaceted role that inflammation may play in disrupting both biologic and abiologic components of the overall neural interface circuit. To combat neuro-inflammation and improve recording quality, the field is actively progressing from traditional inorganic materials towards approaches that either minimizes the microelectrode footprint or that incorporate compliant materials, bioactive molecules, conducting polymers or nanomaterials. However, the immune-privileged cortical tissue introduces an added complexity compared to other biomedical applications that remains to be fully understood. This review provides a comprehensive reflection on the current understanding of the key failure modes that may impact intracortical microelectrode performance. In addition, a detailed overview of the current status of various materials-based approaches that have gained interest for neural interfacing applications is presented, and key challenges that remain to be overcome are discussed. Finally, we present our vision on the future directions of materials-based treatments to improve intracortical microelectrodes for neural interfacing.
Collapse
Affiliation(s)
- Mehdi Jorfi
- Adolphe Merkle Institute, University of Fribourg, Rte de l'Ancienne Papeterie, CH-1723 Marly, Switzerland
| | | | | | | |
Collapse
|
23
|
Xie X, Rieth L, Williams L, Negi S, Bhandari R, Caldwell R, Sharma R, Tathireddy P, Solzbacher F. Long-term reliability of Al2O3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation. J Neural Eng 2014; 11:026016. [PMID: 24658358 DOI: 10.1088/1741-2560/11/2/026016] [Citation(s) in RCA: 75] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE We focus on improving the long-term stability and functionality of neural interfaces for chronic implantation by using bilayer encapsulation. APPROACH We evaluated the long-term reliability of Utah electrode array (UEA) based neural interfaces encapsulated by 52 nm of atomic layer deposited Al2O3 and 6 µm of Parylene C bilayer, and compared these to devices with the baseline Parylene-only encapsulation. Three variants of arrays including wired, wireless, and active UEAs were used to evaluate this bilayer encapsulation scheme, and were immersed in phosphate buffered saline (PBS) at 57 °C for accelerated lifetime testing. MAIN RESULTS The median tip impedance of the bilayer encapsulated wired UEAs increased from 60 to 160 kΩ during the 960 days of equivalent soak testing at 37 °C, the opposite trend to that typically observed for Parylene encapsulated devices. The loss of the iridium oxide tip metallization and etching of the silicon tip in PBS solution contributed to the increase of impedance. The lifetime of fully integrated wireless UEAs was also tested using accelerated lifetime measurement techniques. The bilayer coated devices had stable power-up frequencies at ∼910 MHz and constant radio-frequency signal strength of -50 dBm during up to 1044 days (still under testing) of equivalent soaking time at 37 °C. This is a significant improvement over the lifetime of ∼100 days achieved with Parylene-only encapsulation at 37 °C. The preliminary samples of bilayer coated active UEAs with a flip-chip bonded ASIC chip had a steady current draw of ∼3 mA during 228 days of soak testing at 37 °C. An increase in the current draw has been consistently correlated to device failures, so is a sensitive metric for their lifetime. SIGNIFICANCE The trends of increasing electrode impedance of wired devices and performance stability of wireless and active devices support the significantly greater encapsulation performance of this bilayer encapsulation compared with Parylene-only encapsulation. The bilayer encapsulation should significantly improve the in vivo lifetime of neural interfaces for chronic implantation.
Collapse
Affiliation(s)
- Xianzong Xie
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Xie X, Rieth L, Negi S, Bhandari R, Caldwell R, Sharma R, Tathireddy P, Solzbacher F. SELF ALIGNED TIP DEINSULATION OF ATOMIC LAYER DEPOSITED AL 2O 3 AND PARYLENE C COATED UTAH ELECTRODE ARRAY BASED NEURAL INTERFACES. JOURNAL OF MICROMECHANICS AND MICROENGINEERING : STRUCTURES, DEVICES, AND SYSTEMS 2014; 24:035003. [PMID: 24771981 PMCID: PMC3994722 DOI: 10.1088/0960-1317/24/3/035003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
The recently developed alumina and Parylene C bi-layer encapsulation improved the lifetime of neural interfaces. Tip deinsulation of Utah electrode array based neural interfaces is challenging due to the complex 3D geometries and high aspect ratios of the devices. A three-step self-aligned process was developed for tip deinsulation of bilayer encapsulated arrays. The deinsulation process utilizes laser ablation to remove Parylene C, O2 reactive ion etching to remove carbon and Parylene residues, and buffered oxide etch to remove alumina deposited by atomic layer deposition, and expose the IrOx tip metallization. The deinsulated iridium oxide area was characterized by scanning electron microscopy, atomic force microscopy, X-ray photoelectron spectroscopy, and electrochemical impedance spectroscopy to determine the morphology, surface morphology, composition, and electrical properties of the deposited layers and deinsulated tips. The alumina layer was found to prevent the formation of micro cracks on iridium oxide during the laser ablation process, which has been previously reported as a challenge for laser deinsulation of Parylene films. The charge injection capacity, charge storage capacity, and impedance of deinsulated iridium oxide were characterized to determine the deinsulation efficacy compared to Parylene-only insulation. Deinsulated iridium oxide with bilayer encapsulation had higher charge injection capacity (240 vs 320 nC) and similar electrochemical impedance (2.5 vs 2.5 kΩ) compared to deinsulated iridium oxide with only Parylene coating for an area of 2 × 10-4 cm2. Tip impedances were in the ranges of 20 to 50 kΩ, with median of 32 KΩ and standard deviation of 30 kΩ, showing the effectiveness of the self-aligned deinsulation process for alumina and Parylene C bi-layer encapsulation. The relatively uniform tip impedance values demonstrated the consistency of tip exposures.
Collapse
Affiliation(s)
- Xianzong Xie
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 USA
| | - Loren Rieth
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 USA
| | - Sandeep Negi
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 USA
| | | | - Ryan Caldwell
- Department of Bioengineering, University of Utah, Salt Lake City, UT 84112 USA
| | - Rohit Sharma
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 USA
| | - Prashant Tathireddy
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 USA
| | - Florian Solzbacher
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 USA ; Department of Bioengineering, University of Utah, Salt Lake City, UT 84112 USA
| |
Collapse
|
25
|
Wark HAC, Sharma R, Mathews KS, Fernandez E, Yoo J, Christensen B, Tresco P, Rieth L, Solzbacher F, Normann RA, Tathireddy P. A new high-density (25 electrodes/mm²) penetrating microelectrode array for recording and stimulating sub-millimeter neuroanatomical structures. J Neural Eng 2013; 10:045003. [PMID: 23723133 DOI: 10.1088/1741-2560/10/4/045003] [Citation(s) in RCA: 112] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Among the currently available neural interface devices, there has been a need for a penetrating electrode array with a high electrode-count and high electrode-density (the number of electrodes/mm(2)) that can be used for electrophysiological studies of sub-millimeter neuroanatomical structures. We have developed such a penetrating microelectrode array with both a high electrode-density (25 electrodes/mm(2)) and high electrode-count (up to 96 electrodes) for small nervous system structures, based on the existing Utah Slanted Electrode Array (USEA). Such high electrode-density arrays are expected to provide greater access to nerve fibers than the conventionally spaced USEA especially in small diameter nerves. APPROACH One concern for such high density microelectrode arrays is that they may cause a nerve crush-type injury upon implantation. We evaluated this possibility during acute (<10 h) in vivo experiments with electrode arrays implanted into small diameter peripheral nerves of anesthetized rats (sciatic nerve) and cats (pudendal nerve). MAIN RESULTS Successful intrafascicular implantation and viable nerve function was demonstrated via microstimulation, single-unit recordings and histological analysis. Measurements of the electrode impedances and quantified electrode dimensions demonstrated fabrication quality. The results of these experiments show that such high density neural interfaces can be implanted acutely into neural tissue without causing a complete nerve crush injury, while mediating intrafascicular access to fibers in small diameter peripheral nerves. SIGNIFICANCE This new penetrating microelectrode array has characteristics un-matched by other neural interface devices currently available for peripheral nervous system neurophysiological research.
Collapse
Affiliation(s)
- H A C Wark
- Department of Bioengineering, University of Utah, Salt Lake City, UT, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Excimer laser deinsulation of Parylene-C on iridium for use in an activated iridium oxide film-coated Utah electrode array. J Neurosci Methods 2013; 215:78-87. [PMID: 23458659 DOI: 10.1016/j.jneumeth.2013.02.010] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2012] [Revised: 02/06/2013] [Accepted: 02/12/2013] [Indexed: 11/20/2022]
Abstract
Implantable microelectrodes provide a measure to electrically stimulate neurons in the brain and spinal cord and record their electrophysiological activity. A material with a high charge capacity such as activated or sputter-deposited iridium oxide film (AIROF or SIROF) is used as an interface. The Utah electrode array (UEA) uses SIROF for its interface material with neural tissue and oxygen plasma etching (OPE) with an aluminium foil mask to expose the active area, where the interface between the electrode and neural tissue is formed. However, deinsulation of Parylene-C using OPE has limitations, including the lack of uniformity in the exposed area and reproducibility. While the deinsulation of Parylene-C using an excimer laser is proven to be an alternative for overcoming the limitations, the iridium oxide (IrOx) suffers from fracture when high laser fluence (>1000 mJ/cm2) is used. Iridium (Ir), which has a much higher fracture resistance than IrOx, can be deposited before excimer laser deinsulation and then the exposed Ir film area can be activated by electrochemical treatment to acquire the AIROF. Characterisation of the laser-ablated Ir film and AIROF by surface analysis (X-ray photoelectron spectroscopy, scanning electron microscope, and atomic force microscope) and electrochemical analysis (electrochemical impedance spectroscopy, and cyclic voltammetry) shows that the damage on the Ir film induced by laser irradiation is significantly less than that on SIROF, and the AIROF has a high charge storage capacity. The results show the potential of the laser deinsulation technique for use in high performance AIROF-coated UEA fabrication.
Collapse
|
27
|
Kane SR, Cogan SF, Ehrlich J, Plante TD, McCreery DB, Troyk PR. Electrical performance of penetrating microelectrodes chronically implanted in cat cortex. IEEE Trans Biomed Eng 2013; 60:2153-60. [PMID: 23475329 DOI: 10.1109/tbme.2013.2248152] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Penetrating microelectrode arrays with 2000 μm (2) sputtered iridium oxide (SIROF) electrode sites were implanted in cat cerebral cortex, and their long-term electrochemical performance evaluated in vivo by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and current pulsing. Measurements were made from days 33 to 328 postimplantation. The CV-defined charge storage capacity, measured at 50 mV/s, increased linearly with time over the course of implantation for two arrays and was unchanged for one array. A modest decrease in 1 kHz impedance was also observed. These results suggest an ongoing increase in the apparent electrochemical surface area of the electrodes, which is attributed to electrical leakage pathways arising from cracking of Parylene insulation observed by SEM of explanted arrays. During current pulsing with a 0.0 V interpulse bias, the electrodes readily delivered 8 nC/phase in vitro, but some channels approached or exceeded the water reduction potential during in vivo pulsing. The charge injection capacity in vivo increased linearly with the interpulse bias (0-0.6 V Ag\vert AgCl) from 11.5 to 21.8 nC/ph and with pulse width (150-500 μs) from 8.8 to 14 nC/ph (at 0.0 V bias). These values are lower than those determined from measurements in buffered physiological saline, emphasizing the importance of in vivo measurements in assessing chronic electrode performance. The consequence of current leakage pathways on the charge-injection measurements is also discussed.
Collapse
|
28
|
Abaya T, Blair S, Tathireddy P, Rieth L, Solzbacher F. A 3D glass optrode array for optical neural stimulation. BIOMEDICAL OPTICS EXPRESS 2012; 3:3087-104. [PMID: 23243561 PMCID: PMC3521295 DOI: 10.1364/boe.3.003087] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2012] [Revised: 10/18/2012] [Accepted: 10/23/2012] [Indexed: 05/11/2023]
Abstract
This paper presents optical characterization of a first-generation SiO(2) optrode array as a set of penetrating waveguides for both optogenetic and infrared (IR) neural stimulation. Fused silica and quartz discs of 3-mm thickness and 50-mm diameter were micromachined to yield 10 × 10 arrays of up to 2-mm long optrodes at a 400-μm pitch; array size, length and spacing may be varied along with the width and tip angle. Light delivery and loss mechanisms through these glass optrodes were characterized. Light in-coupling techniques include using optical fibers and collimated beams. Losses involve Fresnel reflection, coupling, scattering and total internal reflection in the tips. Transmission efficiency was constant in the visible and near-IR range, with the highest value measured as 71% using a 50-μm multi-mode in-coupling fiber butt-coupled to the backplane of the device. Transmittance and output beam profiles of optrodes with different geometries was investigated. Length and tip angle do not affect the amount of output power, but optrode width and tip angle influence the beam size and divergence independently. Finally, array insertion in tissue was performed to demonstrate its robustness for optical access in deep tissue.
Collapse
Affiliation(s)
- T.V.F. Abaya
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - S. Blair
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
- Department of BioEngineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - P. Tathireddy
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - L. Rieth
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - F. Solzbacher
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
- Department of BioEngineering, University of Utah, Salt Lake City, Utah 84112,
USA
| |
Collapse
|
29
|
Abaya T, Diwekar M, Blair S, Tathireddy P, Rieth L, Clark G, Solzbacher F. Characterization of a 3D optrode array for infrared neural stimulation. BIOMEDICAL OPTICS EXPRESS 2012; 3:2200-19. [PMID: 23024914 PMCID: PMC3447562 DOI: 10.1364/boe.3.002200] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2012] [Revised: 08/08/2012] [Accepted: 08/10/2012] [Indexed: 05/03/2023]
Abstract
This paper characterizes the Utah Slant Optrode Array (USOA) as a means to deliver infrared light deep into tissue. An undoped crystalline silicon (100) substrate was used to fabricate 10 × 10 arrays of optrodes with rows of varying lengths from 0.5 mm to 1.5 mm on a 400-μm pitch. Light delivery from optical fibers and loss mechanisms through these Si optrodes were characterized, with the primary loss mechanisms being Fresnel reflection, coupling, radiation losses from the tapered shank and total internal reflection in the tips. Transmission at the optrode tips with different optical fiber core diameters and light in-coupling interfaces was investigated. At λ = 1.55μm, the highest optrode transmittance of 34.7%, relative to the optical fiber output power, was obtained with a 50-μm multi-mode fiber butt-coupled to the optrode through an intervening medium of index n = 1.66. Maximum power is directed into the optrodes when using fibers with core diameters of 200 μm or less. In addition, the output power varied with the optrode length/taper such that longer and less tapered optrodes exhibited higher light transmission efficiency. Output beam profiles and potential impacts on physiological tests were also examined. Future work is expected to improve USOA efficiency to greater than 64%.
Collapse
Affiliation(s)
- T.V.F. Abaya
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - M. Diwekar
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - S. Blair
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
- Department of BioEngineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - P. Tathireddy
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - L. Rieth
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - G.A. Clark
- Department of BioEngineering, University of Utah, Salt Lake City, Utah 84112,
USA
| | - F. Solzbacher
- Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112,
USA
- Department of BioEngineering, University of Utah, Salt Lake City, Utah 84112,
USA
| |
Collapse
|
30
|
Bhandari R, Negi S, Solzbacher F. Wafer-scale fabrication of penetrating neural microelectrode arrays. Biomed Microdevices 2010; 12:797-807. [DOI: 10.1007/s10544-010-9434-1] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|