1
|
Thoben C, Stadtler JJ, Simon PR, Raddatz CR, Sehlmeyer M, Zimmermann S. Coated Blade Spray Ion Mobility Spectrometry. Anal Chem 2024; 96:3593-3599. [PMID: 38347729 PMCID: PMC10902811 DOI: 10.1021/acs.analchem.3c05586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/24/2024] [Accepted: 01/29/2024] [Indexed: 02/28/2024]
Abstract
Coated blade spray (CBS) is a microextraction technology with blades that serve as both the extraction device and the electrospray ionization (ESI) emitter. CBS is designed for easy and rapid extraction of analytes in complex matrices as well as ESI directly from the blade. The technology selectively enriches the components of interest on a coated metal blade. The coating consists of a selective polymer. So far, CBS has only been coupled with mass spectrometry but never with ion mobility spectrometry (IMS), where ions are separated and detected based on their ion mobility in a drift gas under the influence of an electric field, while instrumentation is compact and easy to operate so that the advantages of CBS can be particularly well exploited. Therefore, this work focuses on coupling CBS with our previously described ESI-IMS. The ion mobility spectrometer has a drift length of only 75 mm and provides a high resolving power of RP = 100. In this work, preliminary measurements of CBS-IMS are presented. In particular, the detection of benzodiazepines and ketamine in drinks and the pesticide isoproturon in water samples is shown to demonstrate the feasibility of CBS-IMS.
Collapse
Affiliation(s)
- Christian Thoben
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Jannie J. Stadtler
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Paul R. Simon
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Christian-Robert Raddatz
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Merle Sehlmeyer
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| |
Collapse
|
2
|
Thoben C, Schlottmann F, Kobelt T, Nitschke A, Gloeden GL, Naylor CN, Kirk AT, Zimmermann S. Ultra-Fast Ion Mobility Spectrometer for High-Throughput Chromatography. Anal Chem 2023; 95:17073-17081. [PMID: 37953497 PMCID: PMC10666085 DOI: 10.1021/acs.analchem.3c03935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 10/26/2023] [Accepted: 10/30/2023] [Indexed: 11/14/2023]
Abstract
Fast chromatography systems especially developed for high sample throughput applications require sensitive detectors with a high repetition rate. These high throughput techniques, including various chip-based microfluidic designs, often benefit from detectors providing subsequent separation in another dimension, such as mass spectrometry or ion mobility spectrometry (IMS), giving additional information about the analytes or monitoring reaction kinetics. However, subsequent separation is required at a high repetition rate. Here, we therefore present an ultra-fast drift tube IMS operating at ambient pressure. Short drift times while maintaining high resolving power are reached by several key instrumental design features: short length of the drift tube, resistor network of the drift tube, tristate ion shutter, and improved data acquisition electronics. With these design improvements, even slow ions with a reduced mobility of just 0.94 cm2/(V s) have a drift time below 1.6 ms. Such short drift times allow for a significantly increased repetition rate of 600 Hz compared with previously reported values. To further reduce drift times and thus increase the repetition rate, helium can be used as the drift gas, which allows repetition rates of up to 2 kHz. Finally, these significant improvements enable IMS to be used as a detector following ultra-fast separation including chip-based chromatographic systems or droplet microfluidic applications requiring high repetition rates.
Collapse
Affiliation(s)
- Christian Thoben
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Florian Schlottmann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Tim Kobelt
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Alexander Nitschke
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Gian-Luca Gloeden
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Cameron N. Naylor
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Ansgar T. Kirk
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| | - Stefan Zimmermann
- Institute of Electrical Engineering
and Measurement Technology, Department of Sensors and Measurement
Technology, Leibniz University Hannover, Appelstraße 9A, 30167 Hannover, Germany
| |
Collapse
|
3
|
Molecularly imprinted polymers for arbutin and rutin by modified precipitation polymerization and their application for selective extraction of rutin in nutritional supplements. J Pharm Biomed Anal 2021; 205:114294. [PMID: 34375783 DOI: 10.1016/j.jpba.2021.114294] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/28/2021] [Accepted: 07/29/2021] [Indexed: 11/19/2022]
Abstract
Molecularly imprinted polymers (MIPs) for glycosides, arbutin (ARB) and rutin (RUT), were prepared using methacrylamide (MAM) and 4-vinylpyridine (4-VPY) as functional monomers and divinylbenzene as a crosslinker by modified precipitation polymerization. The template molecule, ARB or RUT, was first dissolved in methanol, followed by precipitation polymerization using a mixture of acetonitrile and toluene as a porogenic solvent. The molar ratios of the template molecule, MAM and 4-VPY were optimized to achieve a high molecular recognition ability for ARB and RUT. The retention and molecular recognition properties of these MIPs were evaluated in HILIC or normal-phase mode. With an increase in the acetonitrile content in the mobile phase, the retention factor of ARB or RUT was increased. Furthermore, the MIPs for ARB and RUT showed the highest imprinting factors of 3.65 and 66.5 for the template molecules, respectively. Hydrogen bonding interactions such as N⋯H-O, C=O⋯H-O and NH⋯O-H between 4-VPY or MAM and hydroxy groups of d-glucose or d-rutinose could function in the recognition of a glycone. Furthermore, hydrogen bonding interactions between functional monomers and the hydroxy group(s) of hydroquinone or quercetin could function in the recognition of an aglycone. These results suggest that the MIPs could recognize both a glycone and aglycone via hydrogen bonding interactions. Furthermore, MIPs for RUT were successfully applied to extract RUT in nutritional supplements.
Collapse
|
4
|
Zarejousheghani M, Rahimi P, Borsdorf H, Zimmermann S, Joseph Y. Molecularly Imprinted Polymer-Based Sensors for Priority Pollutants. SENSORS (BASEL, SWITZERLAND) 2021; 21:2406. [PMID: 33807242 PMCID: PMC8037679 DOI: 10.3390/s21072406] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 03/27/2021] [Accepted: 03/29/2021] [Indexed: 01/05/2023]
Abstract
Globally, there is growing concern about the health risks of water and air pollution. The U.S. Environmental Protection Agency (EPA) has developed a list of priority pollutants containing 129 different chemical compounds. All of these chemicals are of significant interest due to their serious health and safety issues. Permanent exposure to some concentrations of these chemicals can cause severe and irrecoverable health effects, which can be easily prevented by their early identification. Molecularly imprinted polymers (MIPs) offer great potential for selective adsorption of chemicals from water and air samples. These selective artificial bio(mimetic) receptors are promising candidates for modification of sensors, especially disposable sensors, due to their low-cost, long-term stability, ease of engineering, simplicity of production and their applicability for a wide range of targets. Herein, innovative strategies used to develop MIP-based sensors for EPA priority pollutants will be reviewed.
Collapse
Affiliation(s)
- Mashaalah Zarejousheghani
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany; (P.R.); (Y.J.)
- Department Monitoring and Exploration Technologies, Helmholtz Centre for Environmental Research-UFZ, 04318 Leipzig, Germany;
| | - Parvaneh Rahimi
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany; (P.R.); (Y.J.)
| | - Helko Borsdorf
- Department Monitoring and Exploration Technologies, Helmholtz Centre for Environmental Research-UFZ, 04318 Leipzig, Germany;
| | - Stefan Zimmermann
- Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, 30167 Hannover, Germany;
| | - Yvonne Joseph
- Institute of Electronic and Sensor Materials, Faculty of Materials Science and Materials Technology, Technische Universität Bergakademie Freiberg, 09599 Freiberg, Germany; (P.R.); (Y.J.)
| |
Collapse
|
5
|
Li W, Zhang X, Li T, Ji Y, Li R. Molecularly imprinted polymer-enhanced biomimetic paper-based analytical devices: A review. Anal Chim Acta 2021; 1148:238196. [PMID: 33516379 DOI: 10.1016/j.aca.2020.12.071] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2020] [Revised: 12/29/2020] [Accepted: 12/30/2020] [Indexed: 02/07/2023]
Abstract
The popularization of paper-based analytical devices (PADs) in analytical science has fostered research on enhancing their analytical performance for accurate and sensitive assays. With their superb recognition capability and structural stability, molecularly imprinted polymers (MIPs) have been extensively employed as biomimetic receptors for capturing target analytes in various complex matrices. The integration of MIPs as recognition elements with PADs (MIP-PADs) has opened new opportunities for advanced analytical devices with elevated selectivity and sensitivity, as well as a shorter assay time and a lower cost. This review covers recent advances in MIP-PAD fabrication and engineering based on multifarious signal transduction systems such as colorimetry, fluorescence, electrochemistry, photoelectrochemistry, and chemiluminescence. The application of MIP-PADs in the fields of biomedical diagnostics, environmental analysis, and food safety monitoring is also reviewed. Further, the advantages, challenges, and perspectives of MIP-PADs are discussed.
Collapse
Affiliation(s)
- Wang Li
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China
| | - Xiaoyue Zhang
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China
| | - Tingting Li
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China
| | - Yibing Ji
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China.
| | - Ruijun Li
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009, China.
| |
Collapse
|
6
|
Rational Design of Molecularly Imprinted Polymers Using Quaternary Ammonium Cations for Glyphosate Detection. SENSORS 2021; 21:s21010296. [PMID: 33406759 PMCID: PMC7795498 DOI: 10.3390/s21010296] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/15/2020] [Accepted: 12/30/2020] [Indexed: 01/22/2023]
Abstract
Molecularly imprinted polymers have emerged as cost-effective and rugged artificial selective sorbents for combination with different sensors. In this study, quaternary ammonium cations, as functional monomers, were systematically evaluated to design imprinted polymers for glyphosate as an important model compound for electrically charged and highly water-soluble chemical compounds. To this aim, a small pool of monomers were used including (3-acrylamidopropyl)trimethylammonium chloride, [2-(acryloyloxy)ethyl]trimethylammonium chloride, and diallyldimethylammonium chloride. The simultaneous interactions between three positively charged monomers and glyphosate were preliminary evaluated using statistical design of the experiment method. Afterwards, different polymers were synthesized at the gold surface of the quartz crystal microbalance sensor using optimized and not optimized glyphosate-monomers ratios. All synthesized polymers were characterized using atomic force microscopy, contact angle, Fourier-transform infrared, and X-ray photoelectron spectroscopy. Evaluated functional monomers showed promise as highly efficient functional monomers, when they are used together and at the optimized ratio, as predicted by the statistical method. Obtained results from the modified sensors were used to develop a simple model describing the binding characteristics at the surface of the different synthesized polymers. This model helps to develop new synthesis strategies for rational design of the highly selective imprinted polymers and to use as a sensing platform for water soluble and polar targets.
Collapse
|
7
|
Affiliation(s)
- Valérie Pichon
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation-UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS , PSL* Research University , 10 rue Vauquelin , 75005 Paris , France.,Sorbonne Université , 75005 Paris , France
| | - Nathalie Delaunay
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation-UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS , PSL* Research University , 10 rue Vauquelin , 75005 Paris , France
| | - Audrey Combès
- Laboratoire des Sciences Analytiques, Bioanalytiques et Miniaturisation-UMR Chimie Biologie Innovation 8231, ESPCI Paris, CNRS , PSL* Research University , 10 rue Vauquelin , 75005 Paris , France
| |
Collapse
|
8
|
Zarejousheghani M, Lorenz W, Vanninen P, Alizadeh T, Cämmerer M, Borsdorf H. Molecularly Imprinted Polymer Materials as Selective Recognition Sorbents for Explosives: A Review. Polymers (Basel) 2019; 11:polym11050888. [PMID: 31096617 PMCID: PMC6572358 DOI: 10.3390/polym11050888] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 05/09/2019] [Accepted: 05/10/2019] [Indexed: 11/29/2022] Open
Abstract
Explosives are of significant interest to homeland security departments and forensic investigations. Fast, sensitive and selective detection of these chemicals is of great concern for security purposes as well as for triage and decontamination in contaminated areas. To this end, selective sorbents with fast binding kinetics and high binding capacity, either in combination with a sensor transducer or a sampling/sample-preparation method, are required. Molecularly imprinted polymers (MIPs) show promise as cost-effective and rugged artificial selective sorbents, which have a wide variety of applications. This manuscript reviews the innovative strategies developed in 57 manuscripts (published from 2006 to 2019) to use MIP materials for explosives. To the best of our knowledge, there are currently no commercially available MIP-modified sensors or sample preparation methods for explosives in the market. We believe that this review provides information to give insight into the future prospects and potential commercialization of such materials. We warn the readers of the hazards of working with explosives.
Collapse
Affiliation(s)
- Mashaalah Zarejousheghani
- UFZ-Helmholtz Centre for Environmental Research, Department Monitoring and Exploration Technologies, Permoserstraße 15, D-04318 Leipzig, Germany.
| | - Wilhelm Lorenz
- Institute of Chemistry, Food Chemistry and Environmental Chemistry, Martin-Luther-University Halle-Wittenberg, D-06120 Halle, Germany.
| | - Paula Vanninen
- VERIFIN, Finnish Institute for Verification of The Chemical Weapons Convention, Department of Chemistry, University of Helsinki, FI-00014 Helsinki Finland.
| | - Taher Alizadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University College of Science, University of Tehran, 1417466191 Tehran, Iran.
| | - Malcolm Cämmerer
- UFZ-Helmholtz Centre for Environmental Research, Department Monitoring and Exploration Technologies, Permoserstraße 15, D-04318 Leipzig, Germany.
| | - Helko Borsdorf
- UFZ-Helmholtz Centre for Environmental Research, Department Monitoring and Exploration Technologies, Permoserstraße 15, D-04318 Leipzig, Germany.
| |
Collapse
|
9
|
Exploring Matrix Effects on Binding Properties and Characterization of Cotinine Molecularly Imprinted Polymer on Paper-Based Scaffold. Polymers (Basel) 2019; 11:polym11030570. [PMID: 30960554 PMCID: PMC6474114 DOI: 10.3390/polym11030570] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2019] [Revised: 03/09/2019] [Accepted: 03/20/2019] [Indexed: 12/02/2022] Open
Abstract
Commercially available sorbent materials for solid-phase extraction are widely used in analytical laboratories. However, non-selective binding is a major obstacle for sample analysis. To overcome this problem, molecularly imprinted polymers (MIPs) were used as selective adsorbent materials prior to determining target analysts. In this study, the use of non-covalent molecularly imprinted polymers (MIPs) for cotinine adsorption on a paper-based scaffold was studied. Fiberglass paper was used as a paper scaffold for cotinine-selective MIP adsorption with the use of 0.5% agarose gel. The effects of salt, pH, sample matrix, and solvent on the cotinine adsorption and extraction process were investigated. Under optimal conditions, the adsorption isotherm of synthesized MIPs increased to 125.41 µg/g, whereas the maximum adsorption isotherm of non-imprinted polymers (NIPs) was stable at 42.86 µg/g. The ability of the MIP paper scaffold to absorb cotinine in water medium was approximately 1.8–2.8-fold higher than that of the NIP scaffold. From Scatchard analysis, two dissociation constants of MIPs were calculated to be 2.56 and 27.03 µM. Nicotine, myosmine, and N-nitrosonornicotine were used for selectivity testing, and the calculated selectivity factor of cotinine to nicotine, myosmine, and N-nitrosonornicotine was 1.56, 2.69, and 2.05, respectively. Overall, the MIP paper scaffold is promising for simple onsite sampling of cotinine and can be used to assess tobacco smoke exposure.
Collapse
|