1
|
Calero-Cañuelo C, Casado-Carmona FA, Lucena R, Cárdenas S. Sorptive tape-spray tandem mass spectrometry using aluminum foil coated with mixed-mode microparticles. Talanta 2024; 272:125774. [PMID: 38359721 DOI: 10.1016/j.talanta.2024.125774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 02/06/2024] [Accepted: 02/07/2024] [Indexed: 02/17/2024]
Abstract
Direct mass spectrometry (MS) is an exciting strategy in bioanalysis, enabling rapid decision-making in different scenarios. Its application is usually hindered by matrix effects and the typically low concentration of the target compounds in the biofluids. In this sense, combining a previous sample preparation step minimizes or removes these shortcomings. This article describes sorptive tape-spray tandem mass spectrometry (STS-MS/MS) based on mixed-mode particles as a strategy to combine sample preparation and MS analysis in a single device. The technique uses a sorptive tape (ST) consisting of mixed-mode polymeric microparticles (combining ionic exchange and hydrophobic interactions) coated over aluminum foil in a spatial controlled way. The tapes act as the sorptive phases to isolate the analytes from the sample matrix and substrates for STS-MS/MS. The performance of the technique has been evaluated by developing a method to determine codeine in saliva as proof of concept. The affordability of the STs elements allows the preparation of many individual phases at low cost so that several samples can be extracted simultaneously, thus increasing the sample throughput. The extraction variables were optimized following a multivariate approach. Working under the optimum conditions, the limit of detection was 0.3 μg L-1, while the intraday precision, calculated as relative standard deviation (RSD) at three concentration levels, was better than 9.4 %. The accuracy, expressed as relative recovery, was in the range of 78-98 %. The method was also applied to the analysis of real samples. Despite being a powerful strategy, the direct combination of microextraction to MS is not always affordable in all laboratories. For this reason, the STs were also combined with commercial liquid chromatography-MS working under the direct infusion mode to demonstrate the usefulness of the ST in classical extraction workflows.
Collapse
Affiliation(s)
- Carlos Calero-Cañuelo
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain; FI-TRACE Group, Department of Chemistry, Faculty of Science, University of the Balearic Islands, Carretera de Valldemossa Km 7.5, E-07122, Palma de Mallorca, Illes Balears, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| |
Collapse
|
2
|
López-Juan AL, Millán-Santiago J, Benedé JL, Chisvert A, Lucena R, Cárdenas S. Coupling Miniaturized Stir Bar Sorptive Dispersive Microextraction to Needle-Based Electrospray Ionization Emitters for Mass Spectrometry: Determination of Tetrahydrocannabinol in Human Saliva as a Proof of Concept. Anal Chem 2024. [PMID: 38743697 DOI: 10.1021/acs.analchem.4c01297] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
Direct coupling of sample preparation with mass spectrometry (MS) can speed up analysis, enabling faster decision-making. In such combinations, where the analysis time is mainly defined by the extraction procedure, magnetic dispersive solid-phase extraction emerges as a relevant technique because of its rapid workflow. The dispersion and retrieval of the magnetic sorbent are typically uncoupled stages, thus reducing the potential simplicity. Stir bar sorptive dispersive microextraction (SBSDME) is a novel technique that integrates both stages into a single device. Its miniaturization (mSBSDME) makes it more portable and compatible with low-availability samples. This article reports the direct combination of mSBSDME and MS using a needle-based electrospray ionization (NESI) emitter as the interface. This combination is applied to determine tetrahydrocannabinol in saliva samples, a relevant societal problem if the global consumption rates of cannabis are considered. The coupling requires only the transference of the magnet (containing the sorbent and the isolated analyte) from the mSBSDME to the hub of a hypodermic needle, where the online elution occurs. The application of 5 kV on the needle forms an electrospray on its tip, transferring the ionized analyte to the MS inlet. The excellent performance of mSBSDME-NESI-MS/MS relies on the sensitivity (limits of detection as low as 2.25 ng mL-1), the precision (relative standard deviation lower than 15%), and the accuracy (relative recoveries ranged from 87 to 127%) obtained. According to the results, the mSBSDME-NESI-MS/MS technique promises faster and more efficient chemical analysis in MS-based applications.
Collapse
Affiliation(s)
- Andreu L López-Juan
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot E-46100, Valencia, Spain
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, Córdoba E-14071, Spain
| | - Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, Córdoba E-14071, Spain
| | - Juan L Benedé
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot E-46100, Valencia, Spain
| | - Alberto Chisvert
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot E-46100, Valencia, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, Córdoba E-14071, Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, Córdoba E-14071, Spain
| |
Collapse
|
3
|
Millán-Santiago J, Lucena R, Cárdenas S. Bioinspired composite packed in blunt needles, integrated microextraction and determination of oxycodone and naloxone in saliva by substrate spray mass spectrometry. Anal Chim Acta 2024; 1297:342376. [PMID: 38438230 DOI: 10.1016/j.aca.2024.342376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 02/02/2024] [Accepted: 02/13/2024] [Indexed: 03/06/2024]
Abstract
BACKGROUND Opioids are effective painkillers used for medical purposes. Their prolonged ingestion can provoke some side effects (including overdose or constipation) that are minimized by using opioid antagonists (e.g., naloxone). The rapid determination of opioids and their antagonists in biosamples is essential for an effective medical treatment. The direct combination of sample preparation and mass spectrometry (MS) fits well in this scenario. It can speed up the analysis achieving a good selectivity, which relies on the sample preparation and MS, and sensitivity levels. RESULTS This article presents a novel substrate-spray mass spectrometry interface based on a polydopamine-cotton (PDA-Cel) composite hosted inside the inner diameter of a 14-gauge blunt needle to determine oxycodone and naloxone in saliva samples. The needle is used as a microextraction device and a substrate for mass spectrometric analysis. The lack of sharpness of the 14-gauge (14G) blunt needles challenges the formation of the electrospray (ESI), and a commercial 10 μL pipette tip is proposed as a simple solution to this shortcoming. Under the optimum parameters, the proposed method was validated, obtaining limits of detection lower than 0.6 μg L-1, linear range up to 200 μg L-1, and linearity better than 0.9915. Relative standard deviation (RSD) and relative recoveries (RR) were studied at three different concentration levels (2, 40, and 200 μg L-1). RSD values were better than 20.7 %, and RR ranged from 90 to 114 %. Finally, a positive sample from a patient under medical treatment was analyzed. SIGNIFICANCE AND NOVELTY 14G blunt needles have been demonstrated as effective extraction devices due to their low price (<0.15 € per extraction unit), their better safety (avoiding finger pricking), and their higher hosting capacity (up to 8 mg of sorbent). The conductivity of stainless steel permits their use as electrospray emitters, making their direct combination to MS easier. The large variety of fibrous sorbents makes this approach versatile enough to be adapted to other analytical problems.
Collapse
Affiliation(s)
- Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS(2)P) Research Group, Analytical Chemistry Department, Instituto Químico para la Energía y el Medioambiente (IQUEMA), University of Córdoba, Campus of Rabanales, Marie Curie Building, E-14071, Córdoba, Spain.
| |
Collapse
|
4
|
Cárdenas S. The role of sustainable materials in sample preparation. Anal Bioanal Chem 2024; 416:2049-2056. [PMID: 37910201 DOI: 10.1007/s00216-023-05015-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 10/18/2023] [Accepted: 10/20/2023] [Indexed: 11/03/2023]
Abstract
Sample preparation is a constantly evolving step in the measurement process with a positive effect on its performance. Its evolution has been marked by an underlying environmental commitment, with simplification, miniaturization, and automation being three of its driving forces. This trends article deepens how the sample preparation can go sustainable through the efficient design of new sorptive materials, either liquid or solid. This objective can be achieved by using natural and/or biodegradable materials as precursors of the functional sorptive phases and by designing materials that simplify the procedures (thus reducing the energy or resources required). Although environmental performance is a crucial aspect of a new material, its applicability is what really defines its incorporation into the sample preparation toolbox. For this reason, their characteristics and more relevant applications will be briefly presented to conclude with the tendency of their use in the very near future.
Collapse
Affiliation(s)
- Soledad Cárdenas
- Affordable and Sustainable Sample Preparation Research Group (AS2P), Departamento de Química Analítica, Instituto Químico Para La Energía y El Medioambiente (IQUEMA), University of Córdoba, Córdoba, Spain.
| |
Collapse
|
5
|
Millán-Santiago J, Lucena R, Cárdenas S. Nylon 6-cellulose composite hosted in a hypodermic needle: Biofluid extraction and analysis by ambient mass spectrometry in a single device. J Pharm Anal 2023; 13:1346-1352. [PMID: 38174121 PMCID: PMC10759252 DOI: 10.1016/j.jpha.2023.06.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 05/28/2023] [Accepted: 06/27/2023] [Indexed: 01/05/2024] Open
Abstract
This study proposes a hypodermic needle (HN) as a sorbent holder and an electrospray (ESI) emitter, thus combining extraction and analysis in a single device. A novel nylon 6-cellulose (N6-Cel) composite sorbent is proposed to extract methadone from oral fluid samples. The cellulosic substrate provides the composite with high porosity, permitting the flow-through of the sample, while the polyamide contributes to the extraction of the analyte. The low price of the devices (considering the holder and the sorbent) contributes to the affordability of the method, and their small size allows easy transportation, opening the door to on-site extractions. Under the optimum conditions, the analyte can be determined by high-resolution ambient ionization mass spectrometry at a limit of detection (LOD) as low as 0.3 μg/L and precision (expressed as relative standard deviation, RSD) better than 9.3%. The trueness, expressed as relative recovery (RR), ranged from 90% to 109%. As high-resolution mass spectrometers are not available in many laboratories, the method was also adapted to low-resolution spectrometers. In this sense, the direct infusion of the eluates in a triple quadrupole-mass spectrometry provided an LOD of 2.2 μg/L. The RSD was better than 5.3%, and the RR ranged from 96% to 121%.
Collapse
Affiliation(s)
- Jaime Millán-Santiago
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) Research Group, Analytical Chemistry Department, Chemical Institute for Energy and Environment (IQUEMA), University of Cordoba, E-14071, Cordoba, Spain
| |
Collapse
|
6
|
Calero-Cañuelo C, Casado-Carmona FA, Lucena R, Cárdenas S. Mixed-mode cationic exchange sorptive tapes combined with direct infusion mass spectrometry for determining opioids in saliva samples. J Chromatogr A 2023; 1702:464097. [PMID: 37244164 DOI: 10.1016/j.chroma.2023.464097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 05/11/2023] [Accepted: 05/22/2023] [Indexed: 05/29/2023]
Abstract
This article describes the synthesis of mixed-mode cationic exchange (MCX) tapes as sorptive phases in bioanalysis, and it faces the determination of methadone and tramadol in saliva as the model analytical problem. The tapes are synthesized using aluminum foil as substrate, which is subsequently covered with double-sided adhesive tape where the MCX particles (ca. 1.4 ± 0.2 mg) finally adhere. MCX particles allow the extraction of the analytes at the physiological pH, where both drugs are positively charged, minimizing the potential co-extraction of endogenous matrix compounds. The extraction conditions were studied considering the main variables (e.g. ionic strength, extraction time, sample dilution). Under the optimum conditions and using direct infusion mass spectrometry as the instrumental technique, detection limits as low as 3.3 μg·L-1 were obtained. The precision calculated at three different levels, and expressed as relative standard deviation, was better than 3.8%. The accuracy, expressed as relative recoveries, ranged from 83 to 113%. The method was finally applied to determine tramadol in saliva samples from patients under medical treatment. This approach opens the door to easily preparing sorptive tapes based on commercial (or ad-hoc synthesized) sorbent particles.
Collapse
Affiliation(s)
- Carlos Calero-Cañuelo
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Francisco Antonio Casado-Carmona
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain
| | - Rafael Lucena
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| | - Soledad Cárdenas
- Affordable and Sustainable Sample Preparation (AS2P) research group, Departamento de Química Analítica, Instituto Químico para la Energía y el Medioambiente IQUEMA, Universidad de Córdoba, Campus de Rabanales, Edificio Marie Curie, E-14071, Córdoba, Spain.
| |
Collapse
|