1
|
Devriese M, Hays C, Jouffrey J, Usureau C, Carmagnat M, Caillat-Zucman S, Taupin JL. Deciphering the role of the conjugate's phycoerythrin label in complement-mediated interference occurring in HLA single antigen Luminex bead assays. HLA 2022; 99:573-579. [PMID: 35411722 DOI: 10.1111/tan.14628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2021] [Revised: 03/19/2022] [Accepted: 04/06/2022] [Indexed: 11/26/2022]
Abstract
Complement-mediated interference is a well described phenomenon in single antigen bead (SAB) Luminex assay that leads to falsely low or negative results for anti-HLA antibody (Ab). In a context of high amount of Ab, the enrichment of the Ab around the bead can lead to complement cascade activation and deposition, thereafter impairing Ab detection. EDTA is now routinely used to circumvent this interference. In this report, we attempted to decipher the role of the phycoerythrin (PE) label conjugated to the secondary Ab in this interference. Indeed, PE is a huge molecule (240 kDa) that could participate to limiting access of the conjugate to its Ab target on the bead. To this purpose, 22 sera displaying complement interference without pre-treatment with EDTA were compared on SAB assay with three detection strategies: the recommended PE-conjugated secondary Ab (IgGPE), an Alexa Fluor 532-conjugated Ab (IgGAF) bearing a tiny 724 Da fluorochrome, and a biotinylated Ab followed by PE-conjugated streptavidin (IgGBiot). Complement interference occurred with the three detection methods, but its depth, defined by the percentage of MFI loss with neat serum, was the highest for IgGPE. Our study highlighted the partial role of the PE fluorochrome in complement interference in SAB assays.
Collapse
Affiliation(s)
- Magali Devriese
- Laboratoire d'Immunologie et Histocompatibilité, Hôpital Saint Louis, Paris, France.,INSERM UMR976, Institut de Recherche Saint-Louis, Université de Paris, Paris, France
| | - Constantin Hays
- Laboratoire d'Immunologie et Histocompatibilité, Hôpital Saint Louis, Paris, France.,INSERM UMR976, Institut de Recherche Saint-Louis, Université de Paris, Paris, France
| | - Julie Jouffrey
- Laboratoire d'Immunologie et Histocompatibilité, Hôpital Saint Louis, Paris, France
| | - Cédric Usureau
- Laboratoire d'Immunologie et Histocompatibilité, Hôpital Saint Louis, Paris, France
| | | | - Sophie Caillat-Zucman
- Laboratoire d'Immunologie et Histocompatibilité, Hôpital Saint Louis, Paris, France.,INSERM UMR976, Institut de Recherche Saint-Louis, Université de Paris, Paris, France
| | - Jean Luc Taupin
- Laboratoire d'Immunologie et Histocompatibilité, Hôpital Saint Louis, Paris, France.,INSERM UMR976, Institut de Recherche Saint-Louis, Université de Paris, Paris, France
| |
Collapse
|
2
|
Abolishing serum interference in detection of HLA antibodies: Who, How, When and Why? Hum Immunol 2019; 80:621-628. [DOI: 10.1016/j.humimm.2019.07.294] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
3
|
Colvin MM, Cook JL, Chang PP, Hsu DT, Kiernan MS, Kobashigawa JA, Lindenfeld J, Masri SC, Miller DV, Rodriguez ER, Tyan DB, Zeevi A. Sensitization in Heart Transplantation: Emerging Knowledge: A Scientific Statement From the American Heart Association. Circulation 2019; 139:e553-e578. [DOI: 10.1161/cir.0000000000000598] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Sensitization, defined as the presence of circulating antibodies, presents challenges for heart transplant recipients and physicians. When present, sensitization can limit a transplantation candidate’s access to organs, prolong wait time, and, in some cases, exclude the candidate from heart transplantation altogether. The management of sensitization is not yet standardized, and current therapies have not yielded consistent results. Although current strategies involve antibody suppression and removal with intravenous immunoglobulin, plasmapheresis, and antibody therapy, newer strategies with more specific targets are being investigated.
Collapse
|
4
|
Photocleavage-based affinity purification of biomarkers from serum: Application to multiplex allergy testing. PLoS One 2018; 13:e0191987. [PMID: 29389948 PMCID: PMC5794080 DOI: 10.1371/journal.pone.0191987] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2017] [Accepted: 01/15/2018] [Indexed: 11/19/2022] Open
Abstract
Multiplex serological immunoassays, such as implemented on microarray or microsphere-based platforms, provide greater information content and higher throughput, while lowering the cost and blood volume required. These features are particularly attractive in pediatric food allergy testing to facilitate high throughput multi-allergen analysis from finger- or heel-stick collected blood. However, the miniaturization and microfluidics necessary for creating multiplex assays make them highly susceptible to the “matrix effect” caused by interference from non-target agents in serum and other biofluids. Such interference can result in lower sensitivity, specificity, reproducibility and quantitative accuracy. These problems have in large part prevented wide-spread implementation of multiplex immunoassays in clinical laboratories. We report the development of a novel method to eliminate the matrix effect by utilizing photocleavable capture antibodies to purify and concentrate blood-based biomarkers (a process termed PC-PURE) prior to detection in a multiplex immunoassay. To evaluate this approach, it was applied to blood-based allergy testing. Patient total IgE was purified and enriched using PC-PURE followed by multiplex microsphere-based detection of allergen-specific IgEs (termed the AllerBead assay). AllerBead was formatted to detect the eight most common pediatric food allergens: milk, soy, wheat, egg, peanuts, tree nuts, fin fish and shellfish, which account for >90% of all pediatric food allergies. 205 serum samples obtained from Boston Children’s Hospital were evaluated. When PC-PURE was employed with AllerBead, excellent agreement was obtained with the standard, non-multiplex, ImmunoCAP® assay (average sensitivity above published negative predictive cutoffs = 96% and average Pearson r = 0.90; average specificity = 97%). In contrast, poor ImmunoCAP®-correlation was observed when PC-PURE was not utilized (average sensitivity above published negative predictive cutoffs = 59% and average Pearson r = 0.61; average specificity = 97%). This approach should be adaptable to improve a wide range of multiplex immunoassays such as in cancer, infectious disease and autoimmune disease.
Collapse
|
5
|
Zhang X, Reinsmoen NL. Comprehensive assessment for serum treatment for single antigen test for detection of HLA antibodies. Hum Immunol 2017; 78:699-703. [PMID: 28899793 DOI: 10.1016/j.humimm.2017.09.001] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 09/06/2017] [Accepted: 09/07/2017] [Indexed: 10/18/2022]
Abstract
The single antigen test is widely used in the field of transplantation to determine the specificity of HLA antibodies. It will be beneficial to standardize the procedure of the single antigen test among HLA laboratories. It is not uncommon that single antigen testing on native sera fails to detect antibodies with very high concentrations. It has been shown that cleavage products of activated complement components may mask strongly binding antibodies in single antigen testing. To overcome inhibition by the activated complement products, sera are pretreated with ethylenediaminetetraacetic acid (EDTA), dithiothreitol (DTT), or heat inactivation before single antigen testing. However, no studies have been published to systemically compare the impact of these treatments on single antigen testing. The aim of this study is to understand the different effects these treatments may have on single antigen test results. We found that mean fluorescence intensity (MFI) obtained from sera treated with EDTA and heat inactivation were nearly identical, while DTT treatment was less potent to remove the inhibition. In addition, sera dilution did not further increase MFI of antibodies after EDTA treatment. Our results provide guidance to choose a pretreatment reagent for single antigen testing, and to compare studies obtained from laboratories using different treatments.
Collapse
Affiliation(s)
- Xiaohai Zhang
- HLA and Immunogenetics Laboratory, Comprehensive Transplant Center, Cedars-Sinai Health System, 8723 Alden Drive, SSB 197, Los Angeles, CA 90048, United States.
| | - Nancy L Reinsmoen
- HLA and Immunogenetics Laboratory, Comprehensive Transplant Center, Cedars-Sinai Health System, 8723 Alden Drive, SSB 197, Los Angeles, CA 90048, United States
| |
Collapse
|
6
|
Quantitative Evaluation of the Impact of Ethylenediaminetetraacetic Acid Pretreatment on Single-Antigen Bead Assay. Transplant Direct 2017; 3:e194. [PMID: 28795145 PMCID: PMC5540632 DOI: 10.1097/txd.0000000000000709] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2017] [Accepted: 05/23/2017] [Indexed: 01/28/2023] Open
Abstract
Background Ethylenediaminetetraacetic acid (EDTA) pretreatment has been shown to overcome complement interference in the single-antigen bead (SAB) assay. However, a quantitative evaluation of its impact on the assay for preemptive application to diverse clinical samples is still lacking. Methods Serum samples from 95 renal transplant candidates were tested with and without EDTA-pretreatment in parallel. Changes in mean fluorescence intensity (MFI) values were analyzed to determine the impact of EDTA-pretreatment and the characteristics of complement interference. Results MFI values from EDTA-treated and untreated sera showed good correlations (r = 0.99) and were linear after excluding outliers (slopes, 1; intercepts, −63.7 and −24.2 for class I and II, respectively). Using an assay cutoff of 2000 MFI, positive/negative assignments were concordant for 99% of the 9215 class I beads and 9025 class II beads tested. As defined by an MFI increment above 4000 after EDTA pretreatment, complement interference affected 172 class I beads in 12 samples (12.6%) and 60 class II beads in 7 samples (7.4%), and the findings were supported in 83% and 86% of these samples by dilution studies. In a case study, EDTA pretreatment prevented falsely low MFI values and facilitated the interpretation of titration curves. Finally, EDTA pretreatment reduced the coefficient of variance (CV) by 2.1% and 2.4% for class I and II beads respectively (P < 0.0001). Conclusions It is safe to preemptively treat all clinical samples with EDTA before SAB assay to prevent false negative results or falsely low MFI values. EDTA pretreatment has the added benefit of improved assay precision.
Collapse
|
7
|
Hopkins M, Lucas G, Calvert A, Bendukidze N, Green F, Kotecha K, Poles A. Human platelet antigen (HPA)-specific immunoglobulin M antibodies in neonatal alloimmune thrombocytopenia can inhibit the binding of HPA-specific immunoglobulin G antibodies. Transfusion 2017; 57:1267-1271. [PMID: 28236317 DOI: 10.1111/trf.14047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 11/24/2016] [Accepted: 12/14/2016] [Indexed: 11/27/2022]
Abstract
BACKGROUND A term baby with unexplained thrombocytopenia and a platelet (PLT) count of 14 × 109 /L (maternal PLT count was 200 × 109 /L) was investigated for neonatal alloimmune thrombocytopenia. STUDY DESIGN AND METHODS Serologic investigations were performed using the PLT immunofluorescence test (PIFT), monoclonal antibody immobilization of PLT antigens (MAIPA), and a bead-based assay (BBA) with maternal sera taken up to 56 days postdelivery. One serum sample was also separated into "immunoglobulin (Ig)M-rich" and "IgM-depleted" fractions and tested for PLT-specific antibodies. The family was genotyped for HPA. RESULTS HPA-3a-specific IgM antibodies were detected in the PIFT and confirmed in the BBA. PLT-specific IgG HPA-3a antibodies were not detected in the MAIPA assay and BBA in the initial sample but were detected in both techniques in subsequent serum samples. Testing of IgM-rich and IgM-depleted fractions in the MAIPA assay revealed that IgG antibody binding of the IgM-depleted fraction was inhibited by approximately 50% when it was reconstituted with the IgM-rich fraction suggesting that the IgM antibodies blocked the binding of the IgG antibodies. This effect was not observed when the IgM-depleted fraction or untreated serum was diluted with elution buffer. Incompatibility for HPA-3 was identified between the mother and the infant. The infant received one HPA-1a, -5b negative neonatal PLT transfusion, and one random PLT transfusion, with satisfactory outcomes. Both units were later found to be HPA-3b3b. CONCLUSION HPA-3a IgM antibodies can inhibit PLT-specific HPA-3a IgG antibodies in the MAIPA assay.
Collapse
Affiliation(s)
| | - Geoff Lucas
- H&I Department, IBGRL, NHSBT Filton, Bristol, UK
| | | | | | | | - Krishna Kotecha
- Department of Haematology, Leicester Royal Infirmary, Leicester, UK
| | | |
Collapse
|
8
|
Wang J, Meade JR, Brown NK, Weidner JG, Marino SR. EDTA is superior to DTT treatment for overcoming the prozone effect in HLA antibody testing. HLA 2017; 89:82-89. [DOI: 10.1111/tan.12950] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2016] [Revised: 12/01/2016] [Accepted: 12/06/2016] [Indexed: 11/30/2022]
Affiliation(s)
- J. Wang
- Department of Pathology; University of Chicago Medicine; Chicago Illinois
| | - J. R. Meade
- Department of Pathology; University of Chicago Medicine; Chicago Illinois
| | - N. K. Brown
- Department of Pathology; University of Chicago Medicine; Chicago Illinois
| | - J. G. Weidner
- Department of Pathology; University of Chicago Medicine; Chicago Illinois
| | - S. R. Marino
- Department of Pathology; University of Chicago Medicine; Chicago Illinois
| |
Collapse
|
9
|
Tait BD. Detection of HLA Antibodies in Organ Transplant Recipients - Triumphs and Challenges of the Solid Phase Bead Assay. Front Immunol 2016; 7:570. [PMID: 28018342 PMCID: PMC5146910 DOI: 10.3389/fimmu.2016.00570] [Citation(s) in RCA: 83] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2016] [Accepted: 11/23/2016] [Indexed: 01/18/2023] Open
Abstract
This review outlines the development of human leukocyte antigen (HLA) antibody detection assays and their use in organ transplantation in both antibody screening and crossmatching. The development of sensitive solid phase assays such as the enzyme-linked immunosorbent assay technique, and in particular the bead-based technology has revolutionized this field over the last 10-15 years. This revolution however has created a new paradigm in clinical decision making with respect to the detection of low level pretransplant HLA sensitization and its clinical relevance. The relative sensitivities of the assays used are discussed and the relevance of conflicting inter-assay results. Each assay has its advantages and disadvantages and these are discussed. Over the last decade, the bead-based assay utilizing the Luminex® fluorocytometer instrument has become established as the "gold standard" for HLA antibody testing. However, there are still unresolved issues surrounding this technique, such as the presence of denatured HLA molecules on the beads which reveal cryptic epitopes and the issue of appropriate fluorescence cut off values for positivity. The assay has been modified to detect complement binding (CB) in addition to non-complement binding (NCB) HLA antibodies although the clinical relevance of the CB and NCB IgG isotypes is not fully resolved. The increase sensitivity of the Luminex® bead assay over the complement-dependent cytotoxicity crossmatch has permitted the concept of the "virtual crossmatch" whereby the crossmatch is predicted to a high degree of accuracy based on the HLA antibody specificities detected by the solid phase assay. Dialog between clinicians and laboratory staff on an individual patient basis is essential for correct clinical decision making based on HLA antibody results obtained by the various techniques.
Collapse
Affiliation(s)
- Brian D. Tait
- Clinical Services and Research, Australian Red Cross Blood Service, West Melbourne, VIC, Australia
| |
Collapse
|