1
|
Recent advances in the application of atomic force microscopy to structural biology. J Struct Biol 2023; 215:107963. [PMID: 37044358 DOI: 10.1016/j.jsb.2023.107963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2023] [Revised: 02/21/2023] [Accepted: 04/07/2023] [Indexed: 04/14/2023]
Abstract
The application of atomic force microscopy (AFM) for (functional) imaging and manipulating biomolecules at all levels of organization has enabled great progress in the structural biology field over the last decades, contributing to the discovery of novel structural entities of biological significance across many disciplines ranging from biochemistry, biomedicine and biophysics to molecular and cell biology, up to food systems and beyond. AFM has the capability to generate high-resolution topographic images spanning from the submolecular to the (sub)cellular range and can probe biochemical and biophysical sample properties in close to native conditions with excellent temporal resolution. Instrumental developments in the past decade enable dynamical structural and conformational studies of single biomolecules and new techniques for structural and chemical modification of the AFM probe have converted the cantilever into a versatile tool to study different biological phenomena, such as the mechanical stability of biomolecular complexes or the force induced dynamic changes of mechanically stressed proteins at the nanoscopic level. To improve the functionality of AFM and approach dynamic processes of complex biological systems ex vivo, AFM is combined with complementary microscopy, nanoscopy and spectroscopy tools. These multimethodological approaches provide unprecedented possibilities of probing physical, chemical and biological properties of complex cellular systems with high spatio-temporal resolution, leading to novel applications that correlate structural results with functional biochemical, biophysical, immunological, or genetic data on the system under study.
Collapse
|
2
|
Advanced Imaging Approaches to Reveal Molecular Mechanisms Governing Neuroendocrine Secretion. Neuroendocrinology 2023; 113:107-119. [PMID: 34915491 DOI: 10.1159/000521457] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Accepted: 12/09/2021] [Indexed: 11/19/2022]
Abstract
Identification of the molecular mechanisms governing neuroendocrine secretion and resulting intercellular communication is one of the great challenges of cell biology to better understand organism physiology and neurosecretion disruption-related pathologies such as hypertension, neurodegenerative, or metabolic diseases. To visualize molecule distribution and dynamics at the nanoscale, many imaging approaches have been developed and are still emerging. In this review, we provide an overview of the pioneering studies using transmission electron microscopy, atomic force microscopy, total internal reflection microscopy, and super-resolution microscopy in neuroendocrine cells to visualize molecular mechanisms driving neurosecretion processes, including exocytosis and associated fusion pores, endocytosis and associated recycling vesicles, and protein-protein or protein-lipid interactions. Furthermore, the potential and the challenges of these different advanced imaging approaches for application in the study of neuroendocrine cell biology are discussed, aiming to guide researchers to select the best approach for their specific purpose around the crucial but not yet fully understood neurosecretion process.
Collapse
|
3
|
Time-frequency analysis of the tip motion in liquids using the wavelet transform in dynamic atomic force microscopy. NANOTECHNOLOGY 2018; 29:385702. [PMID: 29957597 DOI: 10.1088/1361-6528/aad031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The tip motion of the dynamic atomic force microscope in liquids shows complex transient behaviors when using a low stiffness cantilever. The second flexural mode of the cantilever is momentarily excited. Multiple impacts between the tip and the sample might occur in one oscillation cycle. However, the commonly used Fourier transform method cannot provide time-related information about these transient features. To overcome this limitation, we apply the wavelet transform to perform the time-frequency analysis of the tip motion in liquids. The momentary excitation of the second mode and the phenomenon of multiple impacts are clearly shown in the time-frequency plane of the wavelet scalogram. The instantaneous frequencies and magnitudes of the second mode are extracted by the wavelet ridge analysis, which can provide quantitative estimations of the tip motion in the second mode. Moreover, the relations of the maximum instantaneous magnitude (MIM) to the amplitude setpoint and the Young's modulus of the sample surface are investigated. The results suggest that the MIM can be used to characterize the nanomechanical property of the sample surface at high amplitude setpoints.
Collapse
|
4
|
Simultaneous AFM topography and recognition imaging at the plasma membrane of mammalian cells. Semin Cell Dev Biol 2018; 73:45-56. [DOI: 10.1016/j.semcdb.2017.08.025] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 08/04/2017] [Accepted: 08/08/2017] [Indexed: 10/19/2022]
|
5
|
Phase imaging quality improvement by modification of AFM probes' cantilever. J Microsc 2017; 269:179-186. [PMID: 28815683 DOI: 10.1111/jmi.12613] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2017] [Revised: 06/28/2017] [Accepted: 07/14/2017] [Indexed: 11/29/2022]
Abstract
Imaging of the surface of materials by atomic force microscopy under tapping and phase imaging mode, with use of modified probes is addressed. In this study, the circularly shaped holes located in varying distance from the probe base, were cut out by focused ion beam. Such modification was a consequence of the results of the previous experiments (probe tip sharpening and cantilever thinning) where significant improvement of image quality in tapping and phase imaging mode has been revealed. The solution proposed herein gives similar results, but is much simpler from the technological point of view. Shorter exposition time of the tip onto gallium ions during FIB processing allows to reduce material degradation. The aim of this modification was to change harmonic oscillators' properties in the simplest and fastest way, to obtain stronger signal for higher resonant frequencies, which can be advantageous for improving the quality of imaging in PI mode. Probes shaped in that way were used for AFM investigations with Bruker AFM nanoscope 8. As a testing material, titanium roughness standard sample, supplied by Bruker, was used. The results have shown that the modifications performed within these studies influence the oscillation of the probes, which in some cases may result in deterioration of the imaging quality under tapping mode for one or both self-resonant frequencies. However, phase imaging results obtained using modified probes are of higher quality. The numerical simulations performed by application of finite element method were used to explain the results obtained experimentally. Phenomenon described within this study allows to apply developed modelling methodology for prediction of effects of various modifications on the probes' tip, and as a result, to predict how proposed modifications will affect AFM imaging quality.
Collapse
|
6
|
Abstract
Atomic force microscopy (AFM) has become a well-established technique for nanoscale imaging of samples in air and in liquid. Recent studies have shown that when operated in amplitude-modulation (tapping) mode, atomic or molecular-level resolution images can be achieved over a wide range of soft and hard samples in liquid. In these situations, small oscillation amplitudes (SAM-AFM) enhance the resolution by exploiting the solvated liquid at the surface of the sample. Although the technique has been successfully applied across fields as diverse as materials science, biology and biophysics and surface chemistry, obtaining high-resolution images in liquid can still remain challenging for novice users. This is partly due to the large number of variables to control and optimize such as the choice of cantilever, the sample preparation, and the correct manipulation of the imaging parameters. Here, we present a protocol for achieving high-resolution images of hard and soft samples in fluid using SAM-AFM on a commercial instrument. Our goal is to provide a step-by-step practical guide to achieving high-resolution images, including the cleaning and preparation of the apparatus and the sample, the choice of cantilever and optimization of the imaging parameters. For each step, we explain the scientific rationale behind our choices to facilitate the adaptation of the methodology to every user's specific system.
Collapse
|
7
|
|
8
|
Mapping of elasticity and damping in an α + β titanium alloy through atomic force acoustic microscopy. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2015; 6:767-76. [PMID: 25977847 PMCID: PMC4419657 DOI: 10.3762/bjnano.6.79] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2014] [Accepted: 02/15/2015] [Indexed: 05/28/2023]
Abstract
The distribution of elastic stiffness and damping of individual phases in an α + β titanium alloy (Ti-6Al-4V) measured by using atomic force acoustic microscopy (AFAM) is reported in the present study. The real and imaginary parts of the contact stiffness k (*) are obtained from the contact-resonance spectra and by using these two quantities, the maps of local elastic stiffness and the damping factor are derived. The evaluation of the data is based on the mass distribution of the cantilever with damped flexural modes. The cantilever dynamics model considering damping, which was proposed recently, has been used for mapping of indentation modulus and damping of different phases in a metallic structural material. The study indicated that in a Ti-6Al-4V alloy the metastable β phase has the minimum modulus and the maximum damping followed by α'- and α-phases. Volume fractions of the individual phases were determined by using a commercial material property evaluation software and were validated by using X-ray diffraction (XRD) and electron back-scatter diffraction (EBSD) studies on one of the heat-treated samples. The volume fractions of the phases and the modulus measured through AFAM are used to derive average modulus of the bulk sample which is correlated with the bulk elastic properties obtained by ultrasonic velocity measurements. The average modulus of the specimens estimated by AFAM technique is found to be within 5% of that obtained by ultrasonic velocity measurements. The effect of heat treatments on the ultrasonic attenuation in the bulk sample could also be understood based on the damping measurements on individual phases using AFAM.
Collapse
|
9
|
Local viscoelastic properties of live cells investigated using dynamic and quasi-static atomic force microscopy methods. Biophys J 2014; 106:1033-43. [PMID: 24606928 DOI: 10.1016/j.bpj.2013.12.037] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Revised: 12/27/2013] [Accepted: 12/31/2013] [Indexed: 12/21/2022] Open
Abstract
The measurement of viscoelasticity of cells in physiological environments with high spatio-temporal resolution is a key goal in cell mechanobiology. Traditionally only the elastic properties have been measured from quasi-static force-distance curves using the atomic force microscope (AFM). Recently, dynamic AFM-based methods have been proposed to map the local in vitro viscoelastic properties of living cells with nanoscale resolution. However, the differences in viscoelastic properties estimated from such dynamic and traditional quasi-static techniques are poorly understood. In this work we quantitatively reconstruct the local force and dissipation gradients (viscoelasticity) on live fibroblast cells in buffer solutions using Lorentz force excited cantilevers and present a careful comparison between mechanical properties (local stiffness and damping) extracted using dynamic and quasi-static force spectroscopy methods. The results highlight the dependence of measured viscoelastic properties on both the frequency at which the chosen technique operates as well as the interactions with subcellular components beyond certain indentation depth, both of which are responsible for differences between the viscoelasticity property maps acquired using the dynamic AFM method against the quasi-static measurements.
Collapse
|
10
|
Imaging resolution of AFM with probes modified with FIB. Micron 2014; 66:23-30. [PMID: 25080273 DOI: 10.1016/j.micron.2014.05.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2014] [Revised: 04/23/2014] [Accepted: 05/01/2014] [Indexed: 11/29/2022]
Abstract
This study concerns imaging of the structure of materials using AFM tapping (TM) and phase imaging (PI) mode, using probes modified with focused ion beam (FIB). Three kinds of modifications were applied - thinning of the cantilever, sharpening of the tip and combination of these two modifications. Probes shaped in that way were used for AFM investigations with Bruker AFM Nanoscope 8. As a testing material, titanium roughness standard supplied by Bruker was used. The results show that performed modifications influence the oscillation of the probes. In particular thinning of the cantilever enables one to acquire higher self-resonant frequencies, which can be advantageous for improving the quality of imaging in PI mode. It was found that sharpening the tip improves imaging resolution in tapping mode, which is consistent with existing knowledge, but lowered the quality of high frequency topography images. In this paper the Finite Element Method (FEM) was used to explain the results obtained experimentally.
Collapse
|
11
|
Abstract
We report that atomic force microscopy based high-speed nanomechanical analysis can identify components of complex heterogeneous synthetic and biological membranes from the measured spectrum of nanomechanical properties. We have investigated phase separated ternary lipid bilayers and purple membranes of Halobacterium salinarum. The nanomechanical spectra recorded on these samples identify all membrane components, some of which are difficult to resolve in conventional phase images. This non-destructive approach can aid the design of synthetic lipid bilayers and studies lateral organization of complex heterogeneous cellular membranes.
Collapse
|
12
|
Unlocking higher harmonics in atomic force microscopy with gentle interactions. BEILSTEIN JOURNAL OF NANOTECHNOLOGY 2014; 5:268-277. [PMID: 24778948 PMCID: PMC3999767 DOI: 10.3762/bjnano.5.29] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2013] [Accepted: 02/14/2014] [Indexed: 05/07/2023]
Abstract
In dynamic atomic force microscopy, nanoscale properties are encoded in the higher harmonics. Nevertheless, when gentle interactions and minimal invasiveness are required, these harmonics are typically undetectable. Here, we propose to externally drive an arbitrary number of exact higher harmonics above the noise level. In this way, multiple contrast channels that are sensitive to compositional variations are made accessible. Numerical integration of the equation of motion shows that the external introduction of exact harmonic frequencies does not compromise the fundamental frequency. Thermal fluctuations are also considered within the detection bandwidth of interest and discussed in terms of higher-harmonic phase contrast in the presence and absence of an external excitation of higher harmonics. Higher harmonic phase shifts further provide the means to directly decouple the true topography from that induced by compositional heterogeneity.
Collapse
|
13
|
Effect of viscoelasticity on the analysis of single-molecule force spectroscopy on live cells. Biophys J 2012; 103:137-45. [PMID: 22828340 DOI: 10.1016/j.bpj.2012.05.044] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2012] [Revised: 04/30/2012] [Accepted: 05/24/2012] [Indexed: 10/28/2022] Open
Abstract
Single-molecule force spectroscopy is used to probe the kinetics of receptor-ligand bonds by applying mechanical forces to an intermediate media on which the molecules reside. When this intermediate media is a live cell, the viscoelastic properties can affect the calculation of rate constants. We theoretically investigate the effect of media viscoelasticity on the common assumption that the bond force is equal to the instantaneous applied force. Dynamic force spectroscopy is simulated between two cells of varying micromechanical properties adhered by a single bond with a constant kinetic off-rate. We show that cell and microvilli deformation, and hydrodynamic drag contribute to bond forces that can be 28-90% lower than the applied force for loading rates of 10(3)-10(7) pN/s, resulting in longer bond lifetimes. These longer bond lifetimes are not caused by changes in bond kinetics; rather, they are due to the mechanical response of the intermediate media on which the bonds reside. Under the assumption that the instantaneous bond force is equal to the applied force--thereby ignoring viscoelasticity--leads to 14-39% error in the determination of off-rates. We present an approach that incorporates viscoelastic properties in calculating the instantaneous bond force and kinetic dissociation parameter of the intermolecular bond.
Collapse
|
14
|
Optimization of Q-factor of AFM cantilevers using genetic algorithms. Ultramicroscopy 2012; 115:61-7. [DOI: 10.1016/j.ultramic.2012.01.014] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2011] [Revised: 01/18/2012] [Accepted: 01/26/2012] [Indexed: 10/14/2022]
|
15
|
Mapping nanomechanical properties of live cells using multi-harmonic atomic force microscopy. NATURE NANOTECHNOLOGY 2011; 6:809-14. [PMID: 22081213 DOI: 10.1038/nnano.2011.186] [Citation(s) in RCA: 127] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2011] [Accepted: 09/28/2011] [Indexed: 05/23/2023]
Abstract
The nanomechanical properties of living cells, such as their surface elastic response and adhesion, have important roles in cellular processes such as morphogenesis, mechano-transduction, focal adhesion, motility, metastasis and drug delivery. Techniques based on quasi-static atomic force microscopy techniques can map these properties, but they lack the spatial and temporal resolution that is needed to observe many of the relevant details. Here, we present a dynamic atomic force microscopy method to map quantitatively the nanomechanical properties of live cells with a throughput (measured in pixels/minute) that is ∼10-1,000 times higher than that achieved with quasi-static atomic force microscopy techniques. The local properties of a cell are derived from the 0th, 1st and 2nd harmonic components of the Fourier spectrum of the AFM cantilevers interacting with the cell surface. Local stiffness, stiffness gradient and the viscoelastic dissipation of live Escherichia coli bacteria, rat fibroblasts and human red blood cells were all mapped in buffer solutions. Our method is compatible with commercial atomic force microscopes and could be used to analyse mechanical changes in tumours, cells and biofilm formation with sub-10 nm detail.
Collapse
|
16
|
Physico-mechanical characterisation of cells using atomic force microscopy — Current research and methodologies. J Microbiol Methods 2011; 86:131-9. [DOI: 10.1016/j.mimet.2011.05.021] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2011] [Revised: 05/18/2011] [Accepted: 05/26/2011] [Indexed: 11/21/2022]
|
17
|
Abstract
AFM (atomic force microscopy) analysis, both of fixed cells, and live cells in physiological environments, is set to offer a step change in the research of cellular function. With the ability to map cell topography and morphology, provide structural details of surface proteins and their expression patterns and to detect pico-Newton force interactions, AFM represents an exciting addition to the arsenal of the cell biologist. With the explosion of new applications, and the advent of combined instrumentation such as AFM-confocal systems, the biological application of AFM has come of age. The use of AFM in the area of biomedical research has been proposed for some time, and is one where a significant impact could be made. Fixed cell analysis provides qualitative and quantitative subcellular and surface data capable of revealing new biomarkers in medical pathologies. Image height and contrast, surface roughness, fractal, volume and force analysis provide a platform for the multiparameter analysis of cell and protein functions. Here, we review the current status of AFM in the field and discuss the important contribution AFM is poised to make in the understanding of biological systems.
Collapse
|