1
|
Selby NM, Williams JP, Phillips BE. Application of dynamic contrast enhanced ultrasound in the assessment of kidney diseases. Curr Opin Nephrol Hypertens 2021; 30:138-143. [PMID: 33186215 DOI: 10.1097/mnh.0000000000000664] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
PURPOSE OF REVIEW Many forms of acute and chronic disease are linked to changes in renal blood flow, perfusion, vascular density and hypoxia, but there are no readily available methods to assess these parameters in clinical practice. Dynamic contrast enhanced ultrasound (DCE-US) is a method that provides quantitative assessments of organ perfusion without ionising radiation or risk of nephrotoxicity. It can be performed at the bedside and is suitable for repeated measurements. The purpose of this review is to provide updates from recent publications on the utility of DCE-US in the diagnosis or assessment of renal disease, excluding the evaluation of benign or malignant renal masses. RECENT FINDINGS DCE-US has been applied in clinical studies of acute kidney injury (AKI), renal transplantation, chronic kidney disease (CKD), diabetic kidney disease and to determine acute effects of pharmacological agents on renal haemodynamics. DCE-US can detect changes in renal perfusion across these clinical scenarios and can differentiate healthy controls from those with CKD. In sepsis, reduced DCE-US measures of perfusion may indicate those at increased risk of developing AKI, but this requires confirmation in larger studies as there can be wide individual variation in perfusion measures in acutely unwell patients. Recent studies in transplantation have not provided robust evidence to show that DCE-US can differentiate between different causes of graft dysfunction, although it may show more promise as a prognostic indicator of graft function 1 year after transplant. DCE-US can detect acute haemodynamic changes in response to medication that correlate with changes in renal plasma flow as measured by para-aminohippurate clearance. SUMMARY DCE-US shows promise and has a number of advantages that make it suitable for the assessment of patients with various forms of kidney disease. However, further research is required to evidence its reproducibility and utility before clinical use can be advocated.
Collapse
Affiliation(s)
- Nicholas M Selby
- Division of Medical Sciences and Graduate Entry Medicine, Centre for Kidney Research and Innovation, University of Nottingham, Royal Derby Hospital Centre
- Department of Renal Medicine, Royal Derby Hospital
| | - John P Williams
- Division of Medical Sciences and Graduate Entry Medicine, MRC-Versus Arthritis Centre for Musculoskeletal Ageing Research and Nottingham Biomedical Research Centre, University of Nottingham, Royal Derby Hospital Centre
- Department of Anaesthesia and Critical Care, Royal Derby Hospital, Derby, UK
| | - Bethan E Phillips
- Division of Medical Sciences and Graduate Entry Medicine, MRC-Versus Arthritis Centre for Musculoskeletal Ageing Research and Nottingham Biomedical Research Centre, University of Nottingham, Royal Derby Hospital Centre
| |
Collapse
|
2
|
Li N, Liao Y, Tang J. Characteristic Blood-Perfusion Reduction of Walker 256 Tumor Induced by Diagnostic Ultrasound and Microbubbles. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3069-3079. [PMID: 32782088 DOI: 10.1016/j.ultrasmedbio.2020.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 07/03/2020] [Accepted: 07/13/2020] [Indexed: 06/11/2023]
Abstract
Tumor angiogenesis is characterized by a defective, leaky and fragile microvascular construction, and microbubble-enhanced ultrasound (MEUS) with high-pressure amplitude is capable of disrupting tumor microvasculature and arresting blood perfusion. In this study, we tried to investigate whether the blood perfusion of a malignant tumor can be characteristically interrupted by combining microbubbles and diagnostic ultrasound (US). Twenty-nine Sprague-Dawley (SD) rats with subcutaneous Walker 256 tumors and seven healthy SD rats were included. Fifteen tumors were treated by MEUS, which combined constant microbubble injection and 20 episodes of irradiation by diagnostic US (i.e., acoustic radiation force impulse [ARFI] imaging). The other 14 tumors were treated by ARFI or sham US only. Seven skeleton muscles from healthy SD rats were also treated with MEUS, serving as the control. Contrast-enhanced ultrasound (CEUS) was performed before and after all treatments. The blood perfusion of the tumor MEUS group showed a significant drop immediately after treatment, followed by a quick, incomplete perfusion recovery within 10-20 min. The visual perfusion scoring result was consistent with the quantitative analysis by CEUS peak intensity. However, there were no significant perfusion changes in the tumor control groups or the muscle control group. Histologic examination found severe microvascular disruption and hemorrhage in the MEUS-treated tumors but not in the control groups. Therefore, the treatment combining diagnostic US and microbubbles can specifically decrease or interrupt the blood perfusion of Walker 256 tumors, which could be a potential new imaging method for diagnosing malignant tumors.
Collapse
Affiliation(s)
- Ningshan Li
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Yiyi Liao
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China
| | - Jiawei Tang
- Department of Ultrasound, Xinqiao Hospital, Army Medical University, Chongqing, China.
| |
Collapse
|
3
|
Beaumont NJ, Holmes HL, Gregory AV, Edwards ME, Rojas JD, Gessner RC, Dayton PA, Kline TL, Romero MF, Czernuszewicz TJ. Assessing Polycystic Kidney Disease in Rodents: Comparison of Robotic 3D Ultrasound and Magnetic Resonance Imaging. ACTA ACUST UNITED AC 2020; 1:1126-1136. [PMID: 33521650 DOI: 10.34067/kid.0003912020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
Polycystic kidney disease (PKD) is an inherited disorder characterized by renal cyst formation and enlargement of the kidney. PKD severity can be staged noninvasively by measuring total kidney volume (TKV), a promising biomarker that has recently received regulatory qualification. In preclinical mouse models, where the disease is studied and potential therapeutics are evaluated, the most popular noninvasive method of measuring TKV is magnetic resonance imaging (MRI). Although MRI provides excellent 3D resolution and contrast, these systems are expensive to operate, have long acquisition times, and, consequently, are not heavily used in preclinical PKD research. In this study, a new imaging instrument, based on robotic ultrasound (US), was evaluated as a complementary approach for assessing PKD in rodent models. The objective was to determine the extent to which TKV measurements on the robotic US scanner correlated with both in vivo and ex vivo reference standards (MRI and Vernier calipers, respectively). A cross-sectional study design was implemented that included both PKD-affected mice and healthy wild types, spanning sex and age for a wide range of kidney volumes. It was found that US-derived TKV measurements and kidney lengths were strongly associated with both in vivo MRI and ex vivo Vernier caliper measurements (R 2=0.94 and 0.90, respectively). In addition to measuring TKV, renal vascular density was assessed using acoustic angiography (AA), a novel contrast-enhanced US methodology. AA image intensity, indicative of volumetric vascularity, was seen to have a strong negative correlation with TKV (R 2=0.82), suggesting impaired renal vascular function in mice with larger kidneys. These studies demonstrate that robotic US can provide a rapid and accurate approach for noninvasively evaluating PKD in rodent models.
Collapse
Affiliation(s)
| | - Heather L Holmes
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota
| | | | | | | | | | - Paul A Dayton
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina
| | - Timothy L Kline
- Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota.,Radiology, Mayo Clinic, Rochester, Minnesota
| | - Michael F Romero
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota.,Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota
| | - Tomasz J Czernuszewicz
- SonoVol, Inc., Durham, North Carolina.,Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina
| |
Collapse
|
4
|
The biological response of rodent kidneys to low frequency, full volume diagnostic contrast-enhanced ultrasound imaging: Pilot data. Data Brief 2019; 25:104170. [PMID: 31372478 PMCID: PMC6656985 DOI: 10.1016/j.dib.2019.104170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 06/13/2019] [Accepted: 06/14/2019] [Indexed: 11/24/2022] Open
Abstract
With the growth of contrast-enhanced ultrasound (CEUS) clinically, there are concerns about histologic bioeffects in regards to the implementation of high mechanical index (MI) imaging, such as the imaging sequence used for a specific CEUS technique known as flash-replenishment. The data presented are results from a pilot study, which explored flash-replenishment with high and moderate MI imaging sequences at time points of 24 hours and 2 weeks post imaging. This pilot study was followed by a larger study, which can be found in a journal article entitled “Histological and Blood Chemistry Examination of the Rodent Kidney After Exposure to Flash-Replenishment Ultrasound Contrast Imaging” Nyankima et al., 2019.
Collapse
|