1
|
Qu X, Azuma T, Takagi S. Localized motion imaging for monitoring HIFU therapy: Comparison of modulating frequencies and utilization of square modulating wave. ULTRASONICS 2022; 120:106658. [PMID: 34922218 DOI: 10.1016/j.ultras.2021.106658] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 10/02/2021] [Accepted: 11/28/2021] [Indexed: 06/14/2023]
Abstract
High-intensity focused ultrasound (HIFU) has been successfully used as a minimally invasive cancer therapy method. For monitoring the therapy, the amplitude-modulated (AM) localized motion imaging (LMI) method had been proposed. This paper compares the performance of AM-LMI while using different sine modulating wave frequencies and proposes the utilization of square modulating waves to gain the advantages of both high and low modulating frequencies. A single element therapy transducer with a 2 MHz central frequency was driven by sine modulating waves with different frequencies (approximate 34, 67, 102, 168, and 201 Hz) and by square modulating waves with two frequencies (34 and 67 Hz). An imaging probe with a 5 MHz central frequency and a 20 MHz sampling frequency was mounted in the center hole of the therapy transducer to acquire pulse-echo data, which were used to estimate the tissue oscillation amplitude induced by the acoustic radiation force of the HIFU beam. The decrease ratio of the oscillation amount was then utilized to estimate the coagulated lesion length during the therapy. The comparison of modulating frequencies demonstrated that a higher frequency could bring higher sensitivity to small lesions, while a lower frequency not only gives greater noise robustness but also promotes the ability to estimate lengths of larger lesions. The utilization of a square modulating wave demonstrated its utility to produce tissue oscillation with multiple frequencies and gain the advantages of both high and low modulating frequencies.
Collapse
Affiliation(s)
- Xiaolei Qu
- School of Instrumentation and Optoelectronics Engineering, Beihang University, Beijing, China.
| | - Takashi Azuma
- Graduate School of Engineering, the University of Tokyo, Tokyo, Japan
| | - Shu Takagi
- Graduate School of Engineering, the University of Tokyo, Tokyo, Japan
| |
Collapse
|
2
|
He M, Zhong Z, Zeng D, Gong X, Wang Z, Li F. Effects of sub-atmospheric pressure and dissolved oxygen concentration on lesions generated in ex vivo tissues by high intensity focused ultrasound. Biomed Eng Online 2021; 20:91. [PMID: 34526014 PMCID: PMC8442382 DOI: 10.1186/s12938-021-00926-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 08/28/2021] [Indexed: 11/12/2022] Open
Abstract
Background Acoustic cavitation plays an important role in the medical treatment using high-intensity focused ultrasound (HIFU), but unnecessarily strong cavitation also could deform the morphology and enlarge the size of lesions. It is known that the increase of ambient hydrostatic pressure (Pstat) can control the acoustic cavitation. But the question of how the decrease of Pstat and dissolved oxygen concentration (DOC) influence the strength of cavitation has not been thoroughly answered. In this study, we aimed to investigate the relationship among the Pstat, DOC and the strength of cavitation. Methods Ex vivo bovine liver tissues were immersed in degassed water with different DOC of 1.0 mg/L, 1.5 mg/L and 2.0 mg/L. Ultrasound (US) of 1 MHz and the spatial and temporal average intensity (Isata) of 6500 W/cm2 was used to expose two groups of in vitro bovine livers for 2 s; one group was under atmospheric pressure (Pstat = 1 bar) and the other was under sub-atmospheric pressure (Pstat = 0.1 bar). Acoustic cavitation was detected by a passive cavitation detector (PCD) during the exposure process. Echo signals at the focal zone of HIFU were monitored by B-mode ultrasound imaging before and after exposure. The difference between two pressure groups was tested using paired sample t-test. The difference among different DOC groups was evaluated by one-way analysis of variance (ANOVA). Results The results demonstrated a significant difference of broadband acoustic emissions from the cavitation bubbles, echo signals on B-mode image, morphology of lesions under various conditions of ambient pressure and DOC. The lesion volume in tissue was increased with the increase of ambient pressure and DOC. Conclusion Cavitation could be suppressed through sub-atmospheric pressure and low DOC level in liver tissue, which could provide a method of controlling cavitation in HIFU treatment to avoid unpredictable lesions.
Collapse
Affiliation(s)
- Min He
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China
| | - Zhiqiang Zhong
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China
| | - Deping Zeng
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China.,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China
| | - Xiaobo Gong
- National Engineering Research Center of Ultrasound Medicine, Chongqing, 401121, People's Republic of China
| | - Zhibiao Wang
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China. .,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China.
| | - Faqi Li
- State Key Laboratory of Ultrasound in Medicine and Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China. .,Chongqing Key Laboratory of Biomedical Engineering, Chongqing Medical University, Chongqing, 400016, China.
| |
Collapse
|