1
|
Zeng L, Kang D, Zhu L, Yu DG, Song W. Structurally Diverse Gelatin-Based Electrospun Membranes for Ultrasound Imaging. Adv Healthc Mater 2025; 14:e2404333. [PMID: 39668477 DOI: 10.1002/adhm.202404333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2024] [Revised: 11/26/2024] [Indexed: 12/14/2024]
Abstract
Nanofiber membranes, produced through electrospinning, offer significant promise in the biomedical field due to their large surface area and strong mechanical properties. Their versatility is evident across applications such as drug delivery, wound healing, filtration, catalysis, and heritage conservation. However, the potential of electrospun membranes for advanced biomedical uses, like medical ultrasonic couplants, remains largely untapped. Current ultrasonic couplants have notable limitations, often failing to meet clinical needs and affecting patient comfort during diagnostics. To address this, gelatin/polyvinyl alcohol nanofiber membranes with various fibrous structures are developed and characterized, specifically designed for B-mode ultrasonography. Through multi-fluid electrospinning, three distinct nanofiber structures with average diameters of 325 ± 6.172, 349 ± 9.189, and 361 ± 2.117 nm are created. Electron microscopy confirmed these membranes' uniformity and smooth, hydrophilic surfaces. After crosslinking, the membranes exhibited enhanced mechanical strength and biodegradability. In ultrasound imaging trials, these nanofibers demonstrated superior clarity compared to commonly used polymer materials, revealing detailed body part structures. This study highlights the critical role of diverse nanofiber membranes in ultrasound imaging and positions them as promising alternatives to conventional couplants, with the potential to revolutionize ultrasound diagnostics and therapeutic practices.
Collapse
Affiliation(s)
- Lingcong Zeng
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Dandan Kang
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Linglin Zhu
- Minimally Invasive Tumor Treatment Center, Oncology Department of Huadong Hospital, Shanghai, 200040, China
| | - Deng-Guang Yu
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Wenliang Song
- School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China
| |
Collapse
|
2
|
Meyer T, Anders M, Pietzcker AZ, Doyley M, Görner S, Böhm O, Engl P, Safraou Y, Braun J, Sack I, Tzschätzsch H. Rapid wideband characterization of viscoelastic material properties by Bessel function-based time harmonic ultrasound elastography (B-THE). J Mech Behav Biomed Mater 2024; 160:106746. [PMID: 39303417 DOI: 10.1016/j.jmbbm.2024.106746] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 09/10/2024] [Accepted: 09/14/2024] [Indexed: 09/22/2024]
Abstract
Elastography is an emerging diagnostic technique that uses conventional imaging modalities such as sonography or magnetic resonance imaging to quantify tissue stiffness. However, different elastography methods provide different stiffness values, which require calibration using well-characterized phantoms or tissue samples. A comprehensive, fast, and cost-effective elastography technique for phantoms or tissue samples is still lacking. Therefore, we propose ultrasound Bessel-fit-based time harmonic elastography (B-THE) as a novel tool to provide rapid feedback on stiffness-related shear wave speed (SWS) and viscosity-related wave penetration rate (PR) over a wide range of harmonic vibration frequencies. The method relies on external induction and B-mode capture of cylindrical shear waves that satisfy the Bessel wave equation for efficient fit-based parameter recovery. B-THE was demonstrated in polyacrylamide phantoms in the frequency range of 20-200 Hz and was cross-validated by magnetic resonance elastography (MRE) using clinical 3-T MRI and compact 0.5-T tabletop MRI scanners. Frequency-independent material parameters were derived from rheological models and validated by numerical simulations. B-THE quantified frequency-resolved SWS and PR 13 to 176 times faster than more expensive clinical MRE and tabletop MRE and have a good accuracy (relative deviation to reference: 6 %, 10 % and 4 % respectively). Simulations of liver-mimicking material phantoms showed that a simultaneous fit of SWS and PR based on the fractional Maxwell rheological model outperformed a fit on PR solely. B-THE provides a comprehensive and fast elastography technique for the quantitative characterization of the viscoelastic behavior of soft tissue mimicking materials.
Collapse
Affiliation(s)
- Tom Meyer
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Matthias Anders
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Anton Z Pietzcker
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Marvin Doyley
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, NY, USA
| | - Steffen Görner
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Oliver Böhm
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Pascal Engl
- Department of Physics, Sensor and Ultrasound Technology, University of Applied Sciences Merseburg, Merseburg, Germany
| | - Yasmine Safraou
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Jürgen Braun
- Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Ingolf Sack
- Department of Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Heiko Tzschätzsch
- Institute of Medical Informatics, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.
| |
Collapse
|
3
|
Almashakbeh Y, Shamimi H, Callejas A, Rus G. Using torsional wave elastography to evaluate spring pot parameters in skin tumor mimicking phantoms. Sci Rep 2024; 14:16058. [PMID: 38992074 PMCID: PMC11239839 DOI: 10.1038/s41598-024-66621-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Accepted: 07/02/2024] [Indexed: 07/13/2024] Open
Abstract
Estimating the tissue parameters of skin tumors is crucial for diagnosis and effective therapy in dermatology and related fields. However, identifying the most sensitive biomarkers require an optimal rheological model for simulating skin behavior this remains an ongoing research endeavor. Additionally, the multi-layered structure of the skin introduces further complexity to this task. In order to surmount these challenges, an inverse problem methodology, in conjunction with signal analysis techniques, is being employed. In this study, a fractional rheological model is presented to enhance the precision of skin tissue parameter estimation from the acquired signal from torsional wave elastography technique (TWE) on skin tumor-mimicking phantoms for lab validation and the estimation of the thickness of the cancerous layer. An exhaustive analysis of the spring-pot model (SP) solved by the finite difference time domain (FDTD) is conducted. The results of experiments performed using a TWE probe designed and prototyped in the laboratory were validated against ultrafast imaging carried out by the Verasonics Research System. Twelve tissue-mimicking phantoms, which precisely simulated the characteristics of skin tissue, were prepared for our experimental setting. The experimental data from these bi-layer phantoms were measured using a TWE probe, and the parameters of the skin tissue were estimated using inverse problem-solving. The agreement between the two datasets was evaluated by comparing the experimental data obtained from the TWE technique with simulated data from the SP- FDTD model using Pearson correlation, dynamic time warping (DTW), and time-frequency representation. Our findings show that the SP-FDTD model and TWE are capable of determining the mechanical properties of both layers in a bilayer phantom, using a single signal and an inverse problem approach. The ultrafast imaging and the validation of TWE results further demonstrate the robustness and reliability of our technology for a realistic range of phantoms. This fusion of the SP-FDTD model and TWE, as well as inverse problem-solving methods has the potential to have a considerable impact on diagnoses and treatments in dermatology and related fields.
Collapse
Affiliation(s)
- Yousef Almashakbeh
- Department of Allied Engineering Sciences, Facility of Engineering, The Hashemite University, Zarqa, 13133, Jordan.
| | - Hirad Shamimi
- Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, Granada, 18012, Spain
| | - Antonio Callejas
- Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, Granada, 18012, Spain
- Excellence Research Unit, "Modelling Nature" (MNat), Granada, 18071, Spain
| | - Guillermo Rus
- Department of Structural Mechanics, University of Granada, Granada, 18071, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, Granada, 18012, Spain
- Excellence Research Unit, "Modelling Nature" (MNat), Granada, 18071, Spain
| |
Collapse
|
4
|
Jawli A, Aldehani W, Nabi G, Huang Z. Tissue-Mimicking Material Fabrication and Properties for Multiparametric Ultrasound Phantoms: A Systematic Review. Bioengineering (Basel) 2024; 11:620. [PMID: 38927856 PMCID: PMC11200625 DOI: 10.3390/bioengineering11060620] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2024] [Revised: 06/09/2024] [Accepted: 06/11/2024] [Indexed: 06/28/2024] Open
Abstract
Medical imaging has allowed for significant advancements in the field of ultrasound procedures over the years. However, each imaging modality exhibits distinct limitations that differently affect their accuracy. It is imperative to ensure the quality of each modality to identify and eliminate these limitations. To achieve this, a tissue-mimicking material (TMM) phantom is utilised for validation. This study aims to perform a systematic analysis of tissue-mimicking materials used for creating ultrasound phantoms. We reviewed 234 studies on the use of TMM phantoms in ultrasound that were published from 2013 to 2023 from two research databases. Our focus was on studies that discussed TMMs' properties and fabrication for ultrasound, elastography, and flow phantoms. The screening process led to the selection of 16 out of 234 studies to include in the analysis. The TMM ultrasound phantoms were categorised into three groups based on the solvent used; each group offers a broad range of physical properties. The water-based material most closely aligns with the properties of ultrasound. This study provides important information about the materials used for ultrasound phantoms. We also compared these materials to real human tissues and found that PVA matches most of the human tissues the best.
Collapse
Affiliation(s)
- Adel Jawli
- Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK
- Department of Clinical Radiology, Sheikh Jaber Al-Ahmad Al-Sabah Hospital, Ministry of Health, Sulaibikhat 13001, Kuwait
| | - Wadhhah Aldehani
- Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK
| | - Ghulam Nabi
- Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK
| | - Zhihong Huang
- Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK
- School of Science and Engineering, University of Dundee, Dundee DD1 4HN, UK
| |
Collapse
|
5
|
Parker KJ, Kabir IE, Doyley MM, Faiyaz A, Uddin MN, Flores G, Schifitto G. Brain elastography in aging relates to fluid/solid trendlines. Phys Med Biol 2024; 69:115037. [PMID: 38670141 DOI: 10.1088/1361-6560/ad4446] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2024] [Accepted: 04/26/2024] [Indexed: 04/28/2024]
Abstract
The relatively new tools of brain elastography have established a general trendline for healthy, aging adult humans, whereby the brain's viscoelastic properties 'soften' over many decades. Earlier studies of the aging brain have demonstrated a wide spectrum of changes in morphology and composition towards the later decades of lifespan. This leads to a major question of causal mechanisms: of the many changes documented in structure and composition of the aging brain, which ones drive the long term trendline for viscoelastic properties of grey matter and white matter? The issue is important for illuminating which factors brain elastography is sensitive to, defining its unique role for study of the brain and clinical diagnoses of neurological disease and injury. We address these issues by examining trendlines in aging from our elastography data, also utilizing data from an earlier landmark study of brain composition, and from a biophysics model that captures the multiscale biphasic (fluid/solid) structure of the brain. Taken together, these imply that long term changes in extracellular water in the glymphatic system of the brain along with a decline in the extracellular matrix have a profound effect on the measured viscoelastic properties. Specifically, the trendlines indicate that water tends to replace solid fraction as a function of age, then grey matter stiffness decreases inversely as water fraction squared, whereas white matter stiffness declines inversely as water fraction to the 2/3 power, a behavior consistent with the cylindrical shape of the axons. These unique behaviors point to elastography of the brain as an important macroscopic measure of underlying microscopic structural change, with direct implications for clinical studies of aging, disease, and injury.
Collapse
Affiliation(s)
- Kevin J Parker
- Department of Electrical and Computer Engineering, University of Rochester, 724 Computer Studies Building, Box 270231, Rochester, NY 14627, United States of America
- Department of Biomedical Engineering, University of Rochester, 204 Goergen Hall, Box 270168, Rochester, NY 14627, United States of America
- Department of Imaging Sciences, University of Rochester Medical Center, 601 Elmwood Ave, Box 648, Rochester, NY 14642, United States of America
| | - Irteza Enan Kabir
- Department of Electrical and Computer Engineering, University of Rochester, 724 Computer Studies Building, Box 270231, Rochester, NY 14627, United States of America
| | - Marvin M Doyley
- Department of Electrical and Computer Engineering, University of Rochester, 724 Computer Studies Building, Box 270231, Rochester, NY 14627, United States of America
- Department of Biomedical Engineering, University of Rochester, 204 Goergen Hall, Box 270168, Rochester, NY 14627, United States of America
- Department of Imaging Sciences, University of Rochester Medical Center, 601 Elmwood Ave, Box 648, Rochester, NY 14642, United States of America
| | - Abrar Faiyaz
- Department of Electrical and Computer Engineering, University of Rochester, 724 Computer Studies Building, Box 270231, Rochester, NY 14627, United States of America
| | - Md Nasir Uddin
- Department of Biomedical Engineering, University of Rochester, 204 Goergen Hall, Box 270168, Rochester, NY 14627, United States of America
- Department of Neurology, University of Rochester Medical Center, 601 Elmwood Ave, Box 673, Rochester, NY 14642, United States of America
| | - Gilmer Flores
- Department of Biomedical Engineering, University of Rochester, 204 Goergen Hall, Box 270168, Rochester, NY 14627, United States of America
| | - Giovanni Schifitto
- Department of Electrical and Computer Engineering, University of Rochester, 724 Computer Studies Building, Box 270231, Rochester, NY 14627, United States of America
- Department of Imaging Sciences, University of Rochester Medical Center, 601 Elmwood Ave, Box 648, Rochester, NY 14642, United States of America
- Department of Neurology, University of Rochester Medical Center, 601 Elmwood Ave, Box 673, Rochester, NY 14642, United States of America
| |
Collapse
|
6
|
Khan S, Goswami S, Feng F, Hollenbach S, Doyley MM, McAleavey SA. Probing Tissue Viscoelasticity With STL Ultrasound Shearwave Spectroscopy Using Cole-Cole Diagrams. IEEE Trans Biomed Eng 2024; 71:916-928. [PMID: 37801375 DOI: 10.1109/tbme.2023.3322420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/08/2023]
Abstract
OBJECTIVE Viscoelasticity is mapped by dispersion in shearwave elastography. Incomplete spectral information of shearwaves is therefore used to estimate mechanical stiffness. We propose capturing the "full-waveform-information" of the shear wave spectra to better resolve complex shear modulus μ* (ω). Approach is validated on phantom models, animal tissues, and feasibility demonstrated on human post-delivery placenta. METHODS We captured robust estimates of μ* in ex-vivo livers subjected to water bath ablation, glutaraldehyde exposure and in the placenta. RESULTS Complex modulus at 200 Hz is more reflective of tissue stiffness than cross-correlation estimate. Bias increased in phantoms with higher gelatin (G) (0.65: 6% G) and oil (O) (0.58: 6% G and 40% O) concentration, compared to elastic phantoms with low stiffness (0.33: 3% G). Actual tissues also reported higher bias in cross-correlation estimate (rabbit liver: 0.61, porcine liver: 2.20, and human placenta: 0.63). Stiffness is sensitive to ablation temperature, where the overall modulus changed from 3.02 KPa at 16 °C to 2.75 KPa at 56 °C in water bath. With exposure to Glutaraldehyde, the overall modulus increased from 2.37 to 9.03 KPa. Reconstruction errors in the loss modulus decreased by 68% with the power law compared to a Maxwell model in porcine livers with Cole-Cole inverse fitting. CONCLUSION Omitting Shear wave attenuation leads to bias. Reconstruction of rheological response with a model is sensitive to its architecture and also the framework. SIGNIFICANCE We use "full spectral information" in ultrasound shear wave elastography to better map μ*(ω) changes in viscoelastic tissues.
Collapse
|
7
|
Cormack JM, Chao YH, Archer BT, Kim K, Spratt KS, Hamilton MF. Focused Shear Wave Beam Propagation in Tissue-Mimicking Phantoms. IEEE Trans Biomed Eng 2024; 71:621-630. [PMID: 37665711 PMCID: PMC10951862 DOI: 10.1109/tbme.2023.3311688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/06/2023]
Abstract
OBJECTIVE Ultrasound transient elastography (TE) technologies for liver stiffness measurement (LSM) utilize vibration of small, flat pistons, which generate shear waves that lack directivity. The most common cause for LSM failure in practice is insufficient shear wave signal at the needed depths. We propose to increase shear wave amplitude by focusing the waves into a directional beam. Here, we demonstrate the generation and propagation of focused shear wave beams (fSWBs) in gelatin. METHODS Directional fSWBs are generated by vibration at 200-400 Hz of a concave piston embedded near the surface of gelatin phantoms and measured with high-frame-rate ultrasound imaging. Five phantoms with a range of stiffnesses are employed. Shear wave speeds assessed by fSWBs are compared with those by radiation-force-based methods (2D SWE). fSWB amplitudes are compared to predictions using an analytical model. RESULTS fSWB-derived shear wave speeds are in good agreement with 2D SWE. The amplitudes of fSWBs are localized to the LSM region and are significantly greater than unfocused shear waves. Overall agreement with theory is observed, with some discrepancies in the theoretical source condition. CONCLUSION Focusing shear waves can increase the signal in the LSM region for TE. Challenges for translation include coupling piston vibration with the patient skin and increased attenuation in vivo compared to the phantoms employed here. SIGNIFICANCE Fibrosis is the most predictive measure of patient outcome in non-alcoholic fatty liver disease. Increased shear wave amplitude in the LSM region can reduce fibrosis assessment failure rates by TE, thus reducing the need for invasive methods like biopsy.
Collapse
|
8
|
Ge GR, Rolland JP, Song W, Nedergaard M, Parker KJ. Fluid compartments influence elastography of the aging mouse brain. Phys Med Biol 2023; 68:095004. [PMID: 36996842 PMCID: PMC10108361 DOI: 10.1088/1361-6560/acc922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Accepted: 03/30/2023] [Indexed: 04/01/2023]
Abstract
Objective. Elastography of the brain has the potential to reveal subtle but clinically important changes in the structure and composition as a function of age, disease, and injury.Approach. In order to quantify the specific effects of aging on mouse brain elastography, and to determine the key factors influencing observed changes, we applied optical coherence tomography reverberant shear wave elastography at 2000 Hz to a group of wild-type healthy mice ranging from young to old age.Main results. We found a strong trend towards increasing stiffness with age, with an approximately 30% increase in shear wave speed from 2 months to 30 months within this sampled group. Furthermore, this appears to be strongly correlated with decreasing measures of whole brain fluid content, so older brains have less water and are stiffer. Rheological models are applied, and the strong effect is captured by specific assignment of changes to the glymphatic compartment of the brain fluid structures along with a correlated change in the parenchymal stiffness.Significance. Short-term and longer-term changes in elastography measures may provide a sensitive biomarker of progressive and fine-scale changes in the glymphatic fluid channels and parenchymal components of the brain.
Collapse
Affiliation(s)
- Gary R Ge
- Institute of Optics, University of Rochester, 480 Intercampus Drive, Box 270186, Rochester, NY 14627, United States of America
| | - Jannick P Rolland
- Institute of Optics, University of Rochester, 480 Intercampus Drive, Box 270186, Rochester, NY 14627, United States of America
| | - Wei Song
- Center for Translational Neuromedicine, University of Rochester Medical Center, 601 Elmwood Avenue, Box 645, Rochester, NY 14642, United States of America
| | - Maiken Nedergaard
- Center for Translational Neuromedicine, University of Rochester Medical Center, 601 Elmwood Avenue, Box 645, Rochester, NY 14642, United States of America
| | - Kevin J Parker
- Department of Electrical and Computer Engineering, University of Rochester, 724 Computer Studies Building, Box 270231, Rochester, NY 14627, United States of America
| |
Collapse
|
9
|
Sharma A, Marapureddy SG, Paul A, Bisht SR, Kakkar M, Thareja P, Mercado-Shekhar KP. Characterizing Viscoelastic Polyvinyl Alcohol Phantoms for Ultrasound Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:497-511. [PMID: 36328889 DOI: 10.1016/j.ultrasmedbio.2022.09.019] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 09/22/2022] [Accepted: 09/24/2022] [Indexed: 06/16/2023]
Abstract
Ultrasound phantoms mimic the acoustic and mechanical properties of native tissues. Polyvinyl alcohol (PVA) phantoms are used extensively as models for validating ultrasound elastography approaches. However, the viscous properties of PVA phantoms have not been investigated adequately. Glycerol is a viscous liquid that has been reported to increase the speed of sound of phantoms. This study aims to assess the acoustic and viscoelastic properties of PVA phantoms and PVA mixed with glycerol at varying concentrations. The phantoms were fabricated with 10% w/v PVA in water with varying concentrations of glycerol (10%, 15% and 20% v/v) and 2% w/v silicon carbide particles as acoustic scatterers. The phantoms were subjected to either one, two, or three 24-h freeze-thaw cycles. The longitudinal sound speeds of all PVA phantoms were measured, and ranged from 1529 to 1660 m/s. Attenuation spectroscopy was performed in the range of 5 to 20 MHz. The measured attenuation followed a power-law relationship with frequency, wherein the power-law fit constants and exponents ranged from 0.02 to 0.1 dB/cm/MHzn and from 1.6 to 1.9, respectively. These results were in agreement with previous reports for soft tissues. Viscoelasticity of PVA phantoms was assessed using rheometry. The estimated values of shear modulus and viscosity using the Kelvin-Voigt and Kelvin-Voigt fractional derivative models were within the range of previously-reported tissue-mimicking phantoms and soft tissues. The number of freeze-thaw cycles were shown to alter the viscosity of PVA phantoms, even in the absence of glycerol. Scanning electron microscopy images of PVA phantoms without glycerol showed a porous hydrogel network, in contrast to those of PVA-glycerol phantoms with non-porous structure. Phantoms fabricated in this study possess tunable acoustic and viscoelastic properties within the range reported for healthy and diseased soft tissues. This study demonstrates that PVA phantoms can be manufactured with glycerol for applications in ultrasound elastography.
Collapse
Affiliation(s)
- Ananya Sharma
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Sai Geetha Marapureddy
- Discipline of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Abhijit Paul
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Sapna R Bisht
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Manik Kakkar
- Discipline of Electrical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Prachi Thareja
- Discipline of Chemical Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India
| | - Karla P Mercado-Shekhar
- Discipline of Biological Engineering, Indian Institute of Technology Gandhinagar, Gandhinagar, Gujarat, India.
| |
Collapse
|
10
|
Yang T, Jin Y, Neogi A. Acoustic Attenuation and Dispersion in Fatty Tissues and Tissue Phantoms Influencing Ultrasound Biomedical Imaging. ACS OMEGA 2023; 8:1319-1330. [PMID: 36643513 PMCID: PMC9835773 DOI: 10.1021/acsomega.2c06750] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 12/13/2022] [Indexed: 06/17/2023]
Abstract
The development of ultrasonic imaging techniques is optimized using artificial tissue phantoms before the practical applications. However, due to the strong attenuation and dispersion, accumulated fatty tissues can significantly impact the resolution and even feasibility of certain ultrasonic imaging modalities. An appropriate characterization of the acoustic properties on fatty phantoms can help the community to overcome the limitations. Some of the existing methods heavily overestimate attenuation coefficients by including the reflection loss and dispersion effects. Hence, in this study, we use numerical simulation-based comparison between two major attenuation measurement configurations. We further pointed out the pulse dispersion in viscoelastic tissue phantoms by simulations, which barely attracted attention in the existing studies. Using the selected attenuation and dispersion testing methods that were selected from the numerical simulation, we experimentally characterized the acoustic properties of common fatty tissue phantoms and compared the acoustic properties with the natural porcine fatty tissue samples. Furthermore, we selected one of the tissue phantoms to construct ultrasound imaging samples with some biomasses. With the known attenuation and dispersion of the tissue phantom, we showed the clarity enhancement of ultrasound imaging by signal post-processing to weaken the attenuation and dispersion effects.
Collapse
Affiliation(s)
- Teng Yang
- Department
of Physics, University of North Texas, Denton, Texas76203, United States
- Department
of Materials Science and Engineering,University
of North Texas, Denton, Texas76207, United States
| | - Yuqi Jin
- Department
of Physics, University of North Texas, Denton, Texas76203, United States
| | - Arup Neogi
- Department
of Physics, University of North Texas, Denton, Texas76203, United States
- Institute
of Fundamental and Frontier Sciences, University
of Electronic Science and Technology of China, Chengdu611731, P. R. China
| |
Collapse
|
11
|
Mori T, Ishikawa N, Mimura H. Bioequivalent and Non-Aqueous Polyurethane Gel for Ultrasound Phantom. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN 2022. [DOI: 10.1252/jcej.21we117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Takato Mori
- Cooperative Major in Medical Photonics, Shizuoka University
| | - Naoto Ishikawa
- Manufacturing Department, Manufacturing Devision2, Kyoto Kagaku Co., Ltd
| | | |
Collapse
|
12
|
Singh A, Pati F, John R. Quantifying viscosity and elasticity using holographic imaging by Rayleigh wave dispersion. OPTICS LETTERS 2022; 47:2214-2217. [PMID: 35486763 DOI: 10.1364/ol.451464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 04/07/2022] [Indexed: 06/14/2023]
Abstract
Viscoelasticity is an important diagnostic parameter to investigate physiological dysfunctions in biological tissues. This Letter reports the quantification of viscoelastic parameters by Rayleigh wave tracing on the surface of tissue-mimicking phantoms using holographic imaging. The Rayleigh wave is induced by an electromechanical actuator on the surface of oil-in-gelatin phantoms and a biological tissue sample followed by holographic imaging and reconstruction of the wave. The frequency-dependent velocity dispersion is fitted to a Voigt model for the quantification of viscous and elastic moduli. The viscoelastic parameters calculated by the proposed method are validated by comparing the results from a conventional mechanical rheometer.
Collapse
|
13
|
Valdez D, Cruz T, Rania S, Badowski G, Cassel K, Wolfgruber T, Grosskreutz S, Dulana LJ, Adonay R, Maskarinec G, Shepherd JA. Technical note: Low clinical efficacy, but good acceptability of a point-of-care electronic palpation device for breast cancer screening for a lower middle-income environment. Med Phys 2022; 49:2663-2671. [PMID: 35106767 PMCID: PMC9007865 DOI: 10.1002/mp.15499] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 12/30/2021] [Accepted: 01/19/2022] [Indexed: 11/06/2022] Open
Abstract
BACKGROUND Late-stage breast cancer rates in the Pacific where mammography services are limited are exceedingly high: Marshall Islands (61%), Palau (94%), and Samoa (79%). Due to the limited medical resources in these areas an alternative accessible technology is needed. The iBreast Exam (iBE) is a point-of-care electronic palpitation device that has a reported sensitivity of 86%. However, little is known about the performance and acceptability of this device for women in the Pacific. METHODS A total of 39 women (ages 42-73 years) were recruited in Guam with 19 women having a mammogram requiring biopsy (Breast Imaging-Reporting and Data System [BI-RADS] category 4 or above) and 20 women with a negative screening mammogram before the study visit. Participants received an iBE exam and completed a 26-item breast health questionnaire to evaluate the iBE. Furthermore, the performance characteristics of the iBE were tested using gelatin breast phantoms in terms of tumor size, tumor depth, and overall breast stiffness. RESULTS The iBE had a sensitivity of 20% (two true positives to eight false negatives) and specificity of 92% (24 false positives to 278 true negatives) when analyzed based on the location of the tumor by quadrant. The iBE also had generally poor agreement according to a Cohen's kappa value of 0.068. The phantom experiments showed that the iBE can detect tumors as deep as 2.5 cm, but only if the lesion is greater than 8 mm in diameter. However, the iBE did demonstrate acceptability; 67% of the women reported that they had high trust in iBE as an early detection device. CONCLUSIONS The iBE had generally poor sensitivity and specificity when tested in a clinical setting which does not allow its use as a screening tool. IMPACT This study demonstrates the need for an alternative screening method other than electronic palpation for lower-middle-income areas.
Collapse
Affiliation(s)
- Dustin Valdez
- Graduate Program in Human Nutrition, University of Hawai’i Manoa, Honolulu, Hawaii, 96822, USA
- University of Hawai’i Cancer Center, Honolulu, Honolulu, Hawaii, 96813, USA
| | | | - Stephanie Rania
- University of Hawai’i Cancer Center, Honolulu, Honolulu, Hawaii, 96813, USA
| | | | - Kevin Cassel
- University of Hawai’i Cancer Center, Honolulu, Honolulu, Hawaii, 96813, USA
| | - Thomas Wolfgruber
- University of Hawai’i Cancer Center, Honolulu, Honolulu, Hawaii, 96813, USA
| | | | | | - Roy Adonay
- Guam Radiology Consultants, Tamuning, 96913, Guam
| | | | - John A. Shepherd
- University of Hawai’i Cancer Center, Honolulu, Honolulu, Hawaii, 96813, USA
| |
Collapse
|
14
|
Zhuo M, Zhang X, Tang Y, Yan Y, Chen Z. Two-dimensional shear wave elastography of the pancreas: measurement success rate, repeatability, and factors affecting measurement values. J Med Ultrason (2001) 2022; 49:261-268. [PMID: 35312874 DOI: 10.1007/s10396-022-01198-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Accepted: 01/24/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE We aimed to evaluate the success rate, repeatability, and factors affecting the measurement values of two-dimensional ultrasonic shear wave elastography (2D-SWE) for measuring pancreatic stiffness. METHODS This prospective study recruited 100 healthy participants. 2D-SWE was performed on the pancreatic head, body, and tail. We compared the success rates of pancreatic stiffness measurements of different body positions and ultrasonic scans, with and without probe pressurization, as well as the effects of sex, age, body mass index (BMI), and region of interest (ROI) depth on measurement values. Intra- and inter-operator repeatabilities were assessed in 20 participants. The influence of ROI depth was verified using a tissue-like phantom. RESULTS The median 2D-SWE measurements of the pancreatic head, body, and tail were 1.44, 1.45, and 1.56 m/s, respectively. The success rates for the pancreatic head and body were significantly higher than that of the tail. The success rate for the semi-recumbent position was higher than that of the supine position (P < 0.001). The intra-operator values for same-day and inter-operator reliability were excellent. Univariate analyses showed that probe pressurization, age, BMI, and ROI depth were correlated with pancreatic shear wave velocity (SWV) (P < 0.05); only ROI depth had a significant effect on SWV values. The inclusion phantom showed that the SWV value increased as the ROI depth increased. CONCLUSIONS 2D-SWE had a high success rate and good repeatability for measuring pancreatic head and body stiffness. The ROI depth was the main factor affecting pancreatic SWV, which increased with ROI depth.
Collapse
Affiliation(s)
- Minling Zhuo
- Department of Ultrasound, Fujian Medical University Affiliated Union Hospital, No.29 Xinquan Road, Fuzhou, 350001, Fujian, China
| | - Xiujuan Zhang
- Department of Ultrasound, Fujian Medical University Affiliated Union Hospital, No.29 Xinquan Road, Fuzhou, 350001, Fujian, China
| | - Yi Tang
- Department of Ultrasound, Fujian Medical University Affiliated Union Hospital, No.29 Xinquan Road, Fuzhou, 350001, Fujian, China
| | - Yan Yan
- Department of Ultrasound, Fujian Medical University Affiliated Union Hospital, No.29 Xinquan Road, Fuzhou, 350001, Fujian, China
| | - Zhikui Chen
- Department of Ultrasound, Fujian Medical University Affiliated Union Hospital, No.29 Xinquan Road, Fuzhou, 350001, Fujian, China.
| |
Collapse
|
15
|
Liquid-Liver Phantom: Mimicking the Viscoelastic Dispersion of Human Liver for Ultrasound- and MRI-Based Elastography. Invest Radiol 2022; 57:502-509. [PMID: 35195086 DOI: 10.1097/rli.0000000000000862] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVES Tissue stiffness can guide medical diagnoses and is exploited as an imaging contrast in elastography. However, different elastography devices show different liver stiffness values in the same subject, hindering comparison of values and establishment of system-independent thresholds for disease detection. There is a need for standardized phantoms that specifically address the viscosity-related dispersion of stiffness over frequency. To improve standardization of clinical elastography across devices and platforms including ultrasound and magnetic resonance imaging (MRI), a comprehensively characterized phantom is introduced that mimics the dispersion of stiffness of the human liver and can be generated reproducibly. MATERIALS AND METHODS The phantom was made of linear polymerized polyacrylamide (PAAm) calibrated to the viscoelastic properties of healthy human liver in vivo as reported in the literature. Stiffness dispersion was analyzed using the 2-parameter springpot model fitted to the dispersion of shear wave speed of PAAm, which was measured by shear rheometry, ultrasound-based time-harmonic elastography, clinical magnetic resonance elastography (MRE), and tabletop MRE in the frequency range of 5 to 3000 Hz. Imaging parameters for ultrasound and MRI, reproducibility, aging behavior, and temperature dependency were assessed. In addition, the frequency bandwidth of shear wave speed of clinical elastography methods (Aplio i900, Canon; Acuson Sequoia, Siemens; FibroScan, EchoSense) was characterized. RESULTS Within the entire frequency range analyzed in this study, the PAAm phantom reproduced well the stiffness dispersion of human liver in vivo despite its fluid properties under static loading (springpot stiffness parameter, 2.14 [95% confidence interval, 2.08-2.19] kPa; springpot powerlaw exponent, 0.367 [95% confidence interval, 0.362-0.373]). Imaging parameters were close to those of liver in vivo with only slight variability in stiffness values of 0.5% (0.4%, 0.6%), 4.1% (3.9%, 4.5%), and -0.63% (-0.67%, -0.58%), respectively, between batches, over a 6-month period, and per °C increase in temperature. CONCLUSIONS The liquid-liver phantom has useful properties for standardization and development of liver elastography. First, it can be used across clinical and experimental elastography devices in ultrasound and MRI. Second, being a liquid, it can easily be adapted in size and shape to specific technical requirements, and by adding inclusions and scatterers. Finally, because the phantom is based on noncrosslinked linear PAAm constituents, it is easy to produce, indicating potential widespread use among researchers and vendors to standardize liver stiffness measurements.
Collapse
|
16
|
Chintada BR, Rau R, Goksel O. Nonlinear Characterization of Tissue Viscoelasticity With Acoustoelastic Attenuation of Shear Waves. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:38-53. [PMID: 34398752 DOI: 10.1109/tuffc.2021.3105339] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Shear-wave elastography (SWE) measures shear-wave speed (SWS), which is related to the underlying shear modulus of soft tissue. SWS in soft tissue changes depending on the amount of external strain that soft tissue is subjected to due to the acoustoelastic (AE) phenomenon. In the literature, variations of SWS as a function of applied uniaxial strain were used for nonlinear characterization, assuming soft tissues to be elastic, although soft tissues are indeed viscoelastic in nature. Hence, nonlinear characterization using SWS alone is insufficient. In this work, we use SWS together with shear-wave attenuation (SWA) during incremental quasi-static compressions in order to derive biomechanical characterization based on the AE theory in terms of well-defined storage and loss moduli. As part of this study, we also quantify the effect of applied strain on measurements of SWS and SWA since such confounding effects need to be taken into account when using SWS and/or SWA, e.g., for staging a disease state, while such effects can also serve as an additional imaging biomarker. Our results from tissue-mimicking phantoms with varying oil percentages and ex vivo porcine liver experiments demonstrate the feasibility of our proposed methods. In both experiments, SWA was observed to decrease with applied strain. For 10% compression in ex vivo livers, shear-wave attenuation decreased, on average, by 28% (93 Np/m), while SWS increased, on average, by 20% (0.26 m/s).
Collapse
|
17
|
Korta Martiartu N, Nambiar S, Nascimento Kirchner I, Paverd C, Cester D, Frauenfelder T, Ruby L, Rominger MB. Sources of Variability in Shear Wave Speed and Dispersion Quantification with Ultrasound Elastography: A Phantom Study. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:3529-3542. [PMID: 34548187 DOI: 10.1016/j.ultrasmedbio.2021.08.013] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Revised: 08/02/2021] [Accepted: 08/14/2021] [Indexed: 06/13/2023]
Abstract
There is a growing interest in quantifying shear-wave dispersion (SWD) with ultrasound shear-wave elastography (SWE). Recent studies suggest that SWD complements shear-wave speed (SWS) in diffuse liver disease diagnosis. To accurately interpret these metrics in clinical practice, we analyzed the impact of operator-dependent acquisition parameters on SWD and SWS measurements. Considered parameters were the acquisition depth, lateral position and size of the region of interest (ROI), as well as the size of the SWE acquisition box. Measurements were performed using the Canon Aplio i800 system (Canon Medical Systems, Otawara, Tochigi, Japan) and four homogeneous elasticity phantoms with certified stiffness values ranging from 3.7 to 44 kPa. In general, SWD exhibited two to three times greater variability than SWS. The acquisition depth was the main variance-contributing factor for both SWS and SWD, which decayed significantly with depth. The lateral ROI position contributed as much as the acquisition depth to the total variance in SWD. Locations close to the initial shear-wave excitation pulse were more robust to biases because of inaccurate probe-phantom coupling. The size of the ROI and acquisition box did not introduce significant variations. These results suggest that future guidelines on multiparametric elastography should account for the depth- and lateral-dependent variability of measurements.
Collapse
Affiliation(s)
- Naiara Korta Martiartu
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland.
| | - Sherin Nambiar
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland
| | - Iara Nascimento Kirchner
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland
| | - Catherine Paverd
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland
| | - Davide Cester
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland
| | - Thomas Frauenfelder
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland
| | - Lisa Ruby
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland
| | - Marga B Rominger
- Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, Rämistrasse 100, 8091 Zürich, Switzerland
| |
Collapse
|
18
|
Hacker L, Joseph J, Ivory AM, Saed MO, Zeqiri B, Rajagopal S, Bohndiek SE. A Copolymer-in-Oil Tissue-Mimicking Material With Tuneable Acoustic and Optical Characteristics for Photoacoustic Imaging Phantoms. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:3593-3603. [PMID: 34152979 DOI: 10.1109/tmi.2021.3090857] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Photoacoustic imaging (PAI) standardisation demands a stable, highly reproducible physical phantom to enable routine quality control and robust performance evaluation. To address this need, we have optimised a low-cost copolymer-in-oil tissue-mimickingmaterial formulation. The base material consists of mineral oil, copolymer and stabiliser with defined Chemical Abstract Service numbers. Speed of sound c(f) and acoustic attenuation coefficient α (f) were characterised over 2-10 MHz; optical absorption μa ( λ ) and reduced scattering μs '( λ ) coefficients over 450-900 nm. Acoustic properties were optimised by modifying base component ratios and optical properties were adjusted using additives. The temporal, thermomechanical and photo-stabilitywere studied, alongwith intra-laboratory fabrication and field-testing. c(f) could be tuned up to (1516±0.6) [Formula: see text] and α (f) to (17.4±0.3)dB · cm -1 at 5 MHz. The base material exhibited negligible μa ( λ ) and μs '( λ ), which could be independently tuned by addition of Nigrosin or TiO2 respectively. These properties were stable over almost a year and were minimally affected by recasting. The material showed high intra-laboratory reproducibility (coefficient of variation <4% for c ( f ), α ( f ), optical transmittance and reflectance), and good photo- and mechanical-stability in the relevant working range (20-40°C). The optimised copolymer-in-oil material represents an excellent candidate for widespread application in PAI phantoms, with properties suitable for broader use in biophotonics and ultrasound imaging standardisation efforts.
Collapse
|
19
|
Kijanka P, Urban MW. Phase Velocity Estimation With Expanded Bandwidth in Viscoelastic Phantoms and Tissues. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:1352-1362. [PMID: 33502973 PMCID: PMC8087630 DOI: 10.1109/tmi.2021.3054950] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Ultrasound shear wave elastography (SWE) is a technique used to measure mechanical properties to evaluate healthy and pathological soft tissues. SWE typically employs an acoustic radiation force (ARF) to generate laterally propagating shear waves that are tracked in the spatiotemporal domains, and algorithms are used to estimate the wave velocity. The tissue viscoelasticity is often examined through analyzing the shear wave phase velocity dispersion curves, which is the variation of phase velocity with frequency or wavelength. A number of available methods to estimate dispersion exist, which can differ in resolution and variance. Moreover, most of these techniques reconstruct dispersion curves for a limited frequency band. In this work, we propose a novel method used for dispersion curve calculation. Our unique approach uses a generalized Stockwell transformation combined with a slant frequency-wavenumber analysis (GST-SFK). We tested the GST-SFK method on numerical phantom data generated using a finite-difference-based method in tissue-mimicking viscoelastic media. In addition, we evaluated the method on numerical shear wave motion data with different amounts of white Gaussian noise added. Additionally, we performed tests on data from custom-made tissue-mimicking viscoelastic phantom experiments, ex vivo porcine liver measurements, and in vivo liver tissue experiments. We compared results from our method with two other techniques used for estimating shear wave phase velocity: the two-dimensional Fourier transform (2D-FT) and the eigenvector (EV) method. Tests carried out revealed that the GST-SFK method provides dispersion curve estimates with lower errors over a wider frequency band in comparison to the 2D-FT and EV methods. In addition, the GST-SFK provides expanded bandwidth by a factor of two or more to be used for phase velocity estimation, which is meaningful for a tissue dispersion analysis in vivo.
Collapse
|
20
|
Kijanka P, Urban MW. Local Phase Velocity Based Imaging of Viscoelastic Phantoms and Tissues. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:389-405. [PMID: 31976887 PMCID: PMC7590236 DOI: 10.1109/tuffc.2020.2968147] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Assessment of soft tissue elasticity and viscosity is of interest in several clinical applications. In this study, we present the feasibility of the local phase velocity based imaging (LPVI) method to create images of phase velocity and viscoelastic parameters in viscoelastic tissue-mimicking materials and soft tissues. In viscoelastic materials, it is necessary to utilize wave-mode isolation using a narrow bandpass filter combined with a directional filter in order to robustly reconstruct phase velocity images with LPVI in viscoelastic media over a wide range of frequencies. A pair of sequential focused acoustic radiation force push beams, focused once on the left-hand side and once on the right-hand side of the probe, was used to produce broadband propagating shear waves. The local shear wave phase velocity is then recovered in the frequency domain for multiple frequencies, for both acquired data sets. Then, a 2-D shear wave velocity map is reconstructed by combining maps from two separate acquisitions. By testing the method on simulated data sets and performing in vitro phantom and in vivo liver tissue experiments, we show the ability of the proposed technique to generate shear wave phase velocity maps at various frequencies in viscoelastic materials. Moreover, a nonlinear least-squares problem is solved in order to locally estimate elasticity and viscosity parameters. The LPVI method with added directional and wavenumber filters can produce phase velocity images, which can be used to characterize the viscoelastic materials.
Collapse
|
21
|
Stahli P, Frenz M, Jaeger M. Bayesian Approach for a Robust Speed-of-Sound Reconstruction Using Pulse-Echo Ultrasound. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:457-467. [PMID: 33026980 DOI: 10.1109/tmi.2020.3029286] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Computed ultrasound tomography in echo mode (CUTE) is a promising ultrasound (US) based multi-modal technique that allows to image the spatial distribution of speed of sound (SoS) inside tissue using hand-held pulse-echo US. It is based on measuring the phase shift of echoes when detected under varying steering angles. The SoS is then reconstructed using a regularized inversion of a forward model that describes the relation between the SoS and echo phase shift. Promising results were obtained in phantoms when using a Tikhonov-type regularization of the spatial gradient (SG) of SoS. In-vivo, however, clutter and aberration lead to an increased phase noise. In many subjects, this phase noise causes strong artifacts in the SoS image when using the SG regularization. To solve this shortcoming, we propose to use a Bayesian framework for the inverse calculation, which includes a priori statistical properties of the spatial distribution of the SoS to avoid noise-related artifacts in the SoS images. In this study, the a priori model is based on segmenting the B-Mode image. We show in a simulation and phantom study that this approach leads to SoS images that are much more stable against phase noise compared to the SG regularization. In a preliminary in-vivo study, a reproducibility in the range of 10 ms-1 was achieved when imaging the SoS of a volunteer's liver from different scanning locations. These results demonstrate the diagnostic potential of CUTE for example for the staging of fatty liver disease.
Collapse
|
22
|
Nitta N, Yamakawa M, Hachiya H, Shiina T. A review of physical and engineering factors potentially affecting shear wave elastography. J Med Ultrason (2001) 2021; 48:403-414. [PMID: 34453649 PMCID: PMC8578095 DOI: 10.1007/s10396-021-01127-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Accepted: 07/15/2021] [Indexed: 01/01/2023]
Abstract
It has been recognized that tissue stiffness provides useful diagnostic information, as with palpation as a screening for diseases such as cancer. In recent years, shear wave elastography (SWE), a technique for evaluating and imaging tissue elasticity quantitatively and objectively in diagnostic imaging, has been put into practical use, and the amount of clinical knowledge about SWE has increased. In addition, some guidelines and review papers regarding technology and clinical applications have been published, and the status as a diagnostic technology is in the process of being established. However, there are still unclear points about the interpretation of shear wave speed (SWS) and converted elastic modulus in SWE. To clarify these, it is important to investigate the factors that affect the SWS and elastic modulus. Therefore, physical and engineering factors that potentially affect the SWS and elastic modulus are discussed in this review paper, based on the principles of SWE and a literature review. The physical factors include the propagation properties of shear waves, mechanical properties (viscoelasticity, nonlinearity, and anisotropy), and size and shape of target tissues. The engineering factors include the region of interest depth and signal processing. The aim of this review paper is not to provide an answer to the interpretation of SWS. It is to provide information for readers to formulate and verify the hypothesis for the interpretation. Therefore, methods to verify the hypothesis for the interpretation are also reviewed. Finally, studies on the safety of SWE are discussed.
Collapse
Affiliation(s)
- Naotaka Nitta
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba, Ibaraki, 305-8564, Japan.
| | - Makoto Yamakawa
- Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| | - Hiroyuki Hachiya
- School of Engineering, Tokyo Institute of Technology, Meguro, Tokyo, 152-8552, Japan
| | - Tsuyoshi Shiina
- Graduate School of Medicine, Kyoto University, Kyoto, 606-8507, Japan
| |
Collapse
|
23
|
Kijanka P, Urban MW. Dispersion curve calculation in viscoelastic tissue-mimicking materials using non-parametric, parametric, and high-resolution methods. ULTRASONICS 2021; 109:106257. [PMID: 32980784 PMCID: PMC7850297 DOI: 10.1016/j.ultras.2020.106257] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 08/25/2020] [Accepted: 09/11/2020] [Indexed: 05/20/2023]
Abstract
Ultrasound shear wave elastography is a modality used for noninvasive, quantitative evaluation of soft tissue mechanical properties. A common way of exploring the tissue viscoelasticity is through analyzing the shear wave velocity dispersion curves. The variation of phase velocity with frequency or wavelength is called the dispersion curve. An increase of the available spectrum to be used for phase velocity estimation is meaningful for a tissue dispersion analysis in vivo. A number of available methods for dispersion relation estimation exist which can give diffuse results due the presence of noise in the measured data. In this work we compare six selected methods used for dispersion curve calculation in viscoelastic materials. Non-parametric, parametric and high-resolution methods were examined and compared. We tested selected methods on digital phantom data created using finite-difference-based method in tissue-mimicking viscoelastic media as well as on the experimental custom tissue-mimicking phantoms. In addition, we evaluated the algorithms with different levels of added white Gaussian noise to the shear wave particle velocity from numerical phantoms. Tests conducted showed that more advanced methods can offer better frequency resolution, and less variance than the fast Fourier transform. In addition, the non-parametric Blackman-Tukey approach exhibits similar performance and can be interchangeably used for shear wave phase velocity dispersion curves calculation.
Collapse
Affiliation(s)
- Piotr Kijanka
- Department of Robotics and Mechatronics, AGH University of Science and Technology, 30-059 Krakow, Poland.
| | - Matthew W Urban
- Department of Radiology, Mayo Clinic, Rochester, MN 55905, USA; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
24
|
Stähli P, Kuriakose M, Frenz M, Jaeger M. Improved forward model for quantitative pulse-echo speed-of-sound imaging. ULTRASONICS 2020; 108:106168. [PMID: 32502892 DOI: 10.1016/j.ultras.2020.106168] [Citation(s) in RCA: 38] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 02/24/2020] [Accepted: 04/24/2020] [Indexed: 05/24/2023]
Abstract
Computed ultrasound tomography in echo mode (CUTE) allows determining the spatial distribution of speed-of-sound (SoS) inside tissue using handheld pulse-echo ultrasound (US). This technique is based on measuring the changing phase of beamformed echoes obtained under varying transmit (Tx) and/or receive (Rx) steering angles. The SoS is reconstructed by inverting a forward model describing how the spatial distribution of SoS is related to the spatial distribution of the echo phase shift. Thanks to the straight-ray approximation, this forward model is linear and can be inverted in real-time when implemented in a state-of-the art system. Here we demonstrate that the forward model must contain two features that were not taken into account so far: (a) the phase shift must be detected between pairs of Tx and Rx angles that are centred around a set of common mid-angles, and (b) it must account for an additional phase shift induced by the offset of the reconstructed position of echoes. In a phantom study mimicking hepatic and cancer imaging, we show that both features are required to accurately predict echo phase shift among different phantom geometries, and that substantially improved quantitative SoS images are obtained compared to the model that has been used so far. The importance of the new model is corroborated by a preliminary volunteer result.
Collapse
Affiliation(s)
- Patrick Stähli
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | - Maju Kuriakose
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| | - Martin Frenz
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland.
| | - Michael Jaeger
- Institute of Applied Physics, University of Bern, Sidlerstrasse 5, 3012 Bern, Switzerland
| |
Collapse
|
25
|
Ormachea J, Parker KJ. Comprehensive Viscoelastic Characterization of Tissues and the Inter-relationship of Shear Wave (Group and Phase) Velocity, Attenuation and Dispersion. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:3448-3459. [PMID: 32988669 DOI: 10.1016/j.ultrasmedbio.2020.08.023] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 08/21/2020] [Accepted: 08/22/2020] [Indexed: 06/11/2023]
Abstract
We report shear wave phase and group velocity, dispersion and attenuation in oil-in-gelatin viscoelastic phantoms and in vivo liver data. Moreover, we measured the power law coefficient from each dispersion curve and used it, together with the shear wave velocity, to calculate an approximate value for attenuation that agrees with independent attenuation measurements. Results in phantoms exhibit good agreement for all parameters with respect to independent mechanical measurements. For in vivo data, the livers of 20 patients were scanned. Results were compared with pathology scores obtained from liver biopsies. Across these cases, increases in shear wave dispersion and attenuation were related to increased steatosis score. It was found that shear wave dispersion and attenuation are experimentally linked, consistent with simple predictions based on the rheology of tissues, and can be used individually or jointly to assess tissue viscosity. Thus, this study indicates the possible utility of using shear wave dispersion and attenuation to non-invasively and quantitatively assess steatosis.
Collapse
Affiliation(s)
- Juvenal Ormachea
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York, USA.
| | - Kevin J Parker
- Department of Electrical and Computer Engineering, University of Rochester, Rochester, New York, USA
| |
Collapse
|
26
|
Wiseman LM, Urban MW, McGough RJ. A parametric evaluation of shear wave speeds estimated with time-of-flight calculations in viscoelastic media. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:1349. [PMID: 33003848 PMCID: PMC7482672 DOI: 10.1121/10.0001813] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 07/30/2020] [Accepted: 08/11/2020] [Indexed: 06/11/2023]
Abstract
Shear wave elasticity imaging (SWEI) uses an acoustic radiation force to generate shear waves, and then soft tissue mechanical properties are obtained by analyzing the shear wave data. In SWEI, the shear wave speed is often estimated with time-of-flight (TOF) calculations. To characterize the errors produced by TOF calculations, three-dimensional (3D) simulated shear waves are described by time-domain Green's functions for a Kelvin-Voigt model evaluated for multiple combinations of the shear elasticity and the shear viscosity. Estimated shear wave speeds are obtained from cross correlations and time-to-peak (TTP) calculations applied to shear wave particle velocities and shear wave particle displacements. The results obtained from these 3D shear wave simulations indicate that TTP calculations applied to shear wave particle displacements yield effective estimates of the shear wave speed if noise is absent, but cross correlations applied to shear wave particle displacements are more robust when the effects of noise and shear viscosity are included. The results also show that shear wave speeds estimated with TTP methods and cross correlations using shear wave particle velocities are more sensitive to increases in shear viscosity and noise, which suggests that superior estimates of the shear wave speed are obtained from noiseless or noisy shear wave particle displacements.
Collapse
Affiliation(s)
- Luke M Wiseman
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan 48824, USA
| | - Matthew W Urban
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Robert J McGough
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan 48824, USA
| |
Collapse
|
27
|
Ge W, Brooker G, Woo J, Rae W, Liu Y, Hyett J. Magnetorheological Gel Mimicking Cervical Ripening as a Potential Model for Evaluating Shear Wave Elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2472-2480. [PMID: 32616430 DOI: 10.1016/j.ultrasmedbio.2020.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 04/27/2020] [Accepted: 05/04/2020] [Indexed: 06/11/2023]
Abstract
The mechanical characteristics of tissue can reflect its biochemical content and, therefore, be a powerful tool in the diagnosis of diseases. Many different methods have been developed for testing the mechanical properties of tissue, such as aspiration, indentation and shear wave elastography. Soft tissues are, however, more complex in behaviour than current commercial tissue-mimicking materials and the models used in measurement methods. Complex behaviours of the tissue include anisotropy and heterogeneous elasticity. The oversimplified models assumed in different measuring methods often neglect the effects of these behaviours, resulting in inaccuracies. The aim of this study was to develop a tissue-mimicking material able to capture the complexity of tissue mechanical behaviour. It will be used to improve mechanical property measuring methods by quantitatively determining how complexities in tissue behaviour affect the measurements made and evaluating the effectiveness of methods designed to overcome it, and will be used to train users for consistency in measurement. The tissue-mimicking material designed in this study focuses on the mechanical properties of the cervix as measured by shear wave elastography. The characteristic behaviours of cervical tissues highlighted are anisotropy, a wide range of elasticity that changes with gestational age and an elasticity gradient across the tissue. Magnetorheological gels were used as their elastic properties can be tuned with the application of magnetic fields. The sample was simulated with the finite-element software COMSOL before being tested by shear wave elastography and the INSTRON universal material testing machine. It had an elasticity range of 6.75-11.06 kPa, which is similar to that of cervical tissue. It was determined that a change in the orientation of the probe with respect to the orientation of anisotropy can cause up to a 30 % increase in measured elasticity. There was a 16% decrease in elasticity across the sample.
Collapse
Affiliation(s)
- Weirong Ge
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, University of Sydney, Sydney, Australia.
| | | | - Joyce Woo
- Royal Prince Alfred Hospital, Sydney, Australia
| | - Will Rae
- Discipline of Medical Imaging Sciences, University of Sydney, Sydney, Australia
| | - Yu Liu
- Australian Centre for Field Robotics, Sydney, Australia
| | - Jon Hyett
- Discipline of Obstetrics, Gynaecology and Neonatology, Central Clinical School, University of Sydney, Sydney, Australia
| |
Collapse
|
28
|
Wiseman LM, Urban MW, McGough RJ. A parametric evaluation of shear wave speeds estimated with time-of-flight calculations in viscoelastic media. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:1349. [PMID: 33003848 PMCID: PMC7482672 DOI: 10.1121/10.0001813#suppl] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2019] [Revised: 07/30/2020] [Accepted: 08/11/2020] [Indexed: 06/11/2023]
Abstract
Shear wave elasticity imaging (SWEI) uses an acoustic radiation force to generate shear waves, and then soft tissue mechanical properties are obtained by analyzing the shear wave data. In SWEI, the shear wave speed is often estimated with time-of-flight (TOF) calculations. To characterize the errors produced by TOF calculations, three-dimensional (3D) simulated shear waves are described by time-domain Green's functions for a Kelvin-Voigt model evaluated for multiple combinations of the shear elasticity and the shear viscosity. Estimated shear wave speeds are obtained from cross correlations and time-to-peak (TTP) calculations applied to shear wave particle velocities and shear wave particle displacements. The results obtained from these 3D shear wave simulations indicate that TTP calculations applied to shear wave particle displacements yield effective estimates of the shear wave speed if noise is absent, but cross correlations applied to shear wave particle displacements are more robust when the effects of noise and shear viscosity are included. The results also show that shear wave speeds estimated with TTP methods and cross correlations using shear wave particle velocities are more sensitive to increases in shear viscosity and noise, which suggests that superior estimates of the shear wave speed are obtained from noiseless or noisy shear wave particle displacements.
Collapse
Affiliation(s)
- Luke M Wiseman
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan 48824, USA
| | - Matthew W Urban
- Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905, USA
| | - Robert J McGough
- Department of Electrical and Computer Engineering, Michigan State University, East Lansing, Michigan 48824, USA
| |
Collapse
|
29
|
Anugrah MA, Suryani S, Ilyas S, Mutmainna I, Fahri AN, Jusmawang, Tahir D. Composite gelatin/Rhizophora SPP particleboards/PVA for soft tissue phantom applications. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2020.108878] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
30
|
Hossain MM, Gallippi CM. Viscoelastic Response Ultrasound Derived Relative Elasticity and Relative Viscosity Reflect True Elasticity and Viscosity: In Silico and Experimental Demonstration. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2020; 67:1102-1117. [PMID: 31899421 PMCID: PMC7341692 DOI: 10.1109/tuffc.2019.2962789] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Viscoelastic response (VisR) ultrasound characterizes the viscoelastic properties of tissue by fitting acoustic radiation force (ARF)-induced displacements in the region of ARF excitation to a 1-D mass-spring-damper (MSD) model. Elasticity and viscosity are calculated separately but relative to the applied ARF amplitude. We refer to these parameters as "relative elasticity (RE)" and "relative viscosity (RV)." We herein test the hypothesis that RE and RV linearly correlate to true elasticity and viscosity in tissue. VisR imaging was simulated in 144 homogeneous viscoelastic materials with varying elasticities and viscosities. Derived RE linearly correlated with material elasticity and varied by an average of 2.52% when the material viscosity changed from 0.1 to 1.3 Pa · s. Derived RV linearly correlated with material viscosity but varied by an average of 102.5% when material elasticity changed from 3.33 to 20 kPa. The effect of elasticity on RV measurement was compensated using the slope of the linear relationship between RV and natural frequency ( ωtextn ). After compensation, RV [Formula: see text] (elasticity compensated RV) linearly correlated with material viscosity and varied by less than 1.00% on average when the modeled shear elastic modulus changed from 3.3 to 20 kPa. In addition to elasticity compensation, variation in ARF amplitude over depth was compensated, yielding REDC and [Formula: see text]. REDC and [Formula: see text] successfully contrasted elastic and viscous inclusions, respectively, in three simulated phantoms. Experimentally, in the homogeneous oil-in-gelatin phantoms and excised livers, REDC linearly correlated with shear wave dispersion ultrasound vibrometry (SDUV) derived shear elastic modulus, and [Formula: see text] linearly correlated with SDUV-derived shear viscosity. In excised livers containing viscoelastic oil-in-gelatin inclusions, the inclusions were successfully contrasted from the liver background by both REDC and [Formula: see text]. These results suggest that RE and RV are relevant for qualitatively assessing the elastic and viscous properties of tissue.
Collapse
|
31
|
Arsalani S, Arsalani S, Hadadian Y, Sampaio DRT, Baffa O, Pavan TZ, Carneiro AAO. The effect of magnetization of natural rubber latex-coated magnetite nanoparticles on shear wave dispersion magneto-motive ultrasound. ACTA ACUST UNITED AC 2019; 64:215019. [DOI: 10.1088/1361-6560/ab4693] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
32
|
Leartprapun N, Iyer RR, Mackey CD, Adie SG. Spatial localization of mechanical excitation affects spatial resolution, contrast, and contrast-to-noise ratio in acoustic radiation force optical coherence elastography. BIOMEDICAL OPTICS EXPRESS 2019; 10:5877-5904. [PMID: 31799053 PMCID: PMC6865116 DOI: 10.1364/boe.10.005877] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2019] [Revised: 09/30/2019] [Accepted: 10/06/2019] [Indexed: 05/05/2023]
Abstract
The notion that a spatially confined mechanical excitation would produce an elastogram with high spatial resolution has motivated the development of various elastography techniques with localized mechanical excitation. However, a quantitative investigation of the effects of spatial localization of mechanical excitation on the spatial resolution of elastograms is still lacking in optical coherence elastography (OCE). Here, we experimentally investigated the effect of spatial localization of acoustic radiation force (ARF) excitation on spatial resolution, contrast, and contrast-to-noise ratio (CNR) of dynamic uniaxial strain elastograms in dynamic ARF-OCE, based on a framework for analyzing the factors that influence the quality of the elastogram at different stages of the elastography workflow. Our results show that localized ARF excitation with a smaller acoustic focal spot size produced a strain elastogram with superior spatial resolution, contrast, and CNR. Our results also suggest that the spatial extent spanned by the displacement response in the sample may connect between the spatial localization of the mechanical excitation and the resulting elastogram quality. The elastography framework and experimental approach presented here may provide a basis for the quantitative analysis of elastogram quality in OCE that can be adapted and applied to different OCE systems and applications.
Collapse
Affiliation(s)
- Nichaluk Leartprapun
- Cornell University, Meinig School of Biomedical Engineering, Weill Hall, Ithaca, New York 14853, USA
| | - Rishyashring R. Iyer
- Cornell University, Meinig School of Biomedical Engineering, Weill Hall, Ithaca, New York 14853, USA
- Present address: University of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, Urbana, Illinois 61801, USA
| | - Colin D. Mackey
- Cornell University, Meinig School of Biomedical Engineering, Weill Hall, Ithaca, New York 14853, USA
| | - Steven G. Adie
- Cornell University, Meinig School of Biomedical Engineering, Weill Hall, Ithaca, New York 14853, USA
| |
Collapse
|
33
|
Ertl M, Raasch N, Hammel G, Harter K, Lang C. Transtemporal Investigation of Brain Parenchyma Elasticity Using 2-D Shear Wave Elastography: Validation Appreciated! ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:1344. [PMID: 30803824 DOI: 10.1016/j.ultrasmedbio.2019.01.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2018] [Revised: 12/13/2018] [Accepted: 01/08/2019] [Indexed: 06/09/2023]
Affiliation(s)
- Michael Ertl
- Clinic for Neurology and Neurophysiology, Klinikum Augsburg, Augsburg, Germany.
| | - Nele Raasch
- Clinic for Neurology and Neurophysiology, Klinikum Augsburg, Augsburg, Germany
| | - Gertrud Hammel
- Chair and Institute of Environmental Medicine, UNIKA-T, Technical University of Munich and Helmholtz Zentrum München, Augsburg, Germany
| | - Katharina Harter
- Chair and Institute of Environmental Medicine, UNIKA-T, Technical University of Munich and Helmholtz Zentrum München, Augsburg, Germany
| | - Christopher Lang
- Clinic for Neurology and Neurophysiology, Klinikum Augsburg, Augsburg, Germany
| |
Collapse
|
34
|
Capilnasiu A, Hadjicharalambous M, Fovargue D, Patel D, Holub O, Bilston L, Screen H, Sinkus R, Nordsletten D. Magnetic resonance elastography in nonlinear viscoelastic materials under load. Biomech Model Mechanobiol 2019; 18:111-135. [PMID: 30151814 PMCID: PMC6373278 DOI: 10.1007/s10237-018-1072-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 08/10/2018] [Indexed: 12/27/2022]
Abstract
Characterisation of soft tissue mechanical properties is a topic of increasing interest in translational and clinical research. Magnetic resonance elastography (MRE) has been used in this context to assess the mechanical properties of tissues in vivo noninvasively. Typically, these analyses rely on linear viscoelastic wave equations to assess material properties from measured wave dynamics. However, deformations that occur in some tissues (e.g. liver during respiration, heart during the cardiac cycle, or external compression during a breast exam) can yield loading bias, complicating the interpretation of tissue stiffness from MRE measurements. In this paper, it is shown how combined knowledge of a material's rheology and loading state can be used to eliminate loading bias and enable interpretation of intrinsic (unloaded) stiffness properties. Equations are derived utilising perturbation theory and Cauchy's equations of motion to demonstrate the impact of loading state on periodic steady-state wave behaviour in nonlinear viscoelastic materials. These equations demonstrate how loading bias yields apparent material stiffening, softening and anisotropy. MRE sensitivity to deformation is demonstrated in an experimental phantom, showing a loading bias of up to twofold. From an unbiased stiffness of [Formula: see text] Pa in unloaded state, the biased stiffness increases to 9767.5 [Formula: see text]1949.9 Pa under a load of [Formula: see text] 34% uniaxial compression. Integrating knowledge of phantom loading and rheology into a novel MRE reconstruction, it is shown that it is possible to characterise intrinsic material characteristics, eliminating the loading bias from MRE data. The framework introduced and demonstrated in phantoms illustrates a pathway that can be translated and applied to MRE in complex deforming tissues. This would contribute to a better assessment of material properties in soft tissues employing elastography.
Collapse
Affiliation(s)
- Adela Capilnasiu
- Division of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
| | - Myrianthi Hadjicharalambous
- Division of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- KIOS Research and Innovation Centre of Excellence, University of Cyprus, Nicosia, Cyprus
| | - Daniel Fovargue
- Division of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Dharmesh Patel
- Institute of Bioengineering, Queen Mary University of London, London, UK
| | - Ondrej Holub
- Division of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Lynne Bilston
- Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
- Neuroscience Research Australia, Sydney, Australia
| | - Hazel Screen
- Institute of Bioengineering, Queen Mary University of London, London, UK
| | - Ralph Sinkus
- Division of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Inserm U1148, LVTS, University Paris Diderot, University Paris 13, 75018, Paris, France
| | - David Nordsletten
- Division of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Biomedical Engineering and Cardiac Surgery, University of Michigan, Ann Arbor, USA
| |
Collapse
|
35
|
Li P, Yang Z, Jiang S. Tissue mimicking materials in image-guided needle-based interventions: A review. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2018; 93:1116-1131. [PMID: 30274042 DOI: 10.1016/j.msec.2018.09.028] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 08/25/2018] [Accepted: 09/07/2018] [Indexed: 12/17/2022]
Abstract
Image-guided interventions are widely employed in clinical medicine, which brings significant revolution in healthcare in recent years. However, it is impossible for medical trainees to experience the image-guided interventions physically in patients due to the lack of certificated skills. Therefore, training phantoms, which are normally tissue mimicking materials, are widely used in medical research, training, and quality assurance. This review focuses on the tissue mimicking materials used in image-guided needle-based interventions. In this case, we need to investigate the microstructure characteristics and mechanical properties (for needle intervention), optical properties and acoustical properties (for imaging) of these training phantoms to compare with the related properties of human real tissues. The widely used base materials, additives and the corresponding concentrations of the training phantoms are summarized from the literatures in recent ten years. The microstructure characteristics, mechanical behavior, optical properties and acoustical properties of the tissue mimicking materials are investigated, accompanied with the common experimental methods, apparatus and theoretical algorithm. The influence of the concentrations of the base materials and additives on these characteristics are compared and classified. In this review, we assess a comprehensive overview of the existing techniques with the main accomplishments, and limitations as well as recommendations for tissue mimicking materials used in image-guided needle-based interventions.
Collapse
Affiliation(s)
- Pan Li
- Centre for Advanced Mechanisms and Robotics, School of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin City 300354, China
| | - Zhiyong Yang
- Centre for Advanced Mechanisms and Robotics, School of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin City 300354, China
| | - Shan Jiang
- Centre for Advanced Mechanisms and Robotics, School of Mechanical Engineering, Tianjin University, No. 135, Yaguan Road, Jinnan District, Tianjin City 300354, China.
| |
Collapse
|
36
|
Chen X, Wang Y, Lu J, Li P. Simultaneous viscosity and elasticity measurement using laser speckle contrast imaging. OPTICS LETTERS 2018; 43:1582-1585. [PMID: 29601035 DOI: 10.1364/ol.43.001582] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 03/03/2018] [Indexed: 06/08/2023]
Abstract
Viscosity and elasticity are closely related to the physiological characteristics of biological tissues. This Letter reports a simultaneous quantitative measurement of these parameters realized with the laser speckle contrast imaging method. The propagation of a Rayleigh wave induced by an acoustic speaker is traced, and the frequency-dependent velocity dispersion is extracted with the frequency-wavenumber spectrum analysis method. The viscosity and elasticity moduli of oil-in-gelatin tissue-mimicking phantoms are calculated by fitting the dispersion curves to the Voigt model. The method is validated by comparing it with the results obtained by using a conventional mechanical rheometer.
Collapse
|
37
|
Performance Study of a Torsional Wave Sensor and Cervical Tissue Characterization. SENSORS 2017; 17:s17092078. [PMID: 28891995 PMCID: PMC5621116 DOI: 10.3390/s17092078] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2017] [Revised: 09/07/2017] [Accepted: 09/08/2017] [Indexed: 02/03/2023]
Abstract
A novel torsional wave sensor designed to characterize mechanical properties of soft tissues is presented in this work. Elastography is a widely used technique since the 1990s to map tissue stiffness. Moreover, quantitative elastography uses the velocity of shear waves to achieve the shear stiffness. This technique exhibits significant limitations caused by the difficulty of the separation between longitudinal and shear waves and the pressure applied while measuring. To overcome these drawbacks, the proposed torsional wave sensor can isolate a pure shear wave, avoiding the possibility of multiple wave interference. It comprises a rotational actuator disk and a piezoceramic receiver ring circumferentially aligned. Both allow the transmission of shear waves that interact with the tissue before being received. Experimental tests are performed using tissue mimicking phantoms and cervical tissues. One contribution is a sensor sensitivity study that has been conducted to evaluate the robustness of the new proposed torsional wave elastography (TWE) technique. The variables object of the study are both the applied pressure and the angle of incidence sensor–phantom. The other contribution consists of a cervical tissue characterization. To this end, three rheological models have fit the experimental data and a static independent testing method has been performed. The proposed methodology permits the reconstruction of the mechanical constants from the propagated shear wave, providing a proof of principle and warranting further studies to confirm the validity of the results.
Collapse
|
38
|
Li W, Belmont B, Greve JM, Manders AB, Downey BC, Zhang X, Xu Z, Guo D, Shih A. Polyvinyl chloride as a multimodal tissue-mimicking material with tuned mechanical and medical imaging properties. Med Phys 2017; 43:5577. [PMID: 27782725 DOI: 10.1118/1.4962649] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The mechanical and imaging properties of polyvinyl chloride (PVC) can be adjusted to meet the needs of researchers as a tissue-mimicking material. For instance, the hardness can be adjusted by changing the ratio of softener to PVC polymer, mineral oil can be added for lubrication in needle insertion, and glass beads can be added to scatter acoustic energy similar to biological tissue. Through this research, the authors sought to develop a regression model to design formulations of PVC with targeted mechanical and multimodal medical imaging properties. METHODS The design of experiment was conducted by varying three factors-(1) the ratio of softener to PVC polymer, (2) the mass fraction of mineral oil, and (3) the mass fraction of glass beads-and measuring the mechanical properties (elastic modulus, hardness, viscoelastic relaxation time constant, and needle insertion friction force) and the medical imaging properties [speed of sound, acoustic attenuation coefficient, magnetic resonance imaging time constants T1 and T2, and the transmittance of the visible light at wavelengths of 695 nm (Tλ695) and 532 nm (Tλ532)] on twelve soft PVC samples. A regression model was built to describe the relationship between the mechanical and medical imaging properties and the values of the three composition factors of PVC. The model was validated by testing the properties of a PVC sample with a formulation distinct from the twelve samples. RESULTS The tested soft PVC had elastic moduli from 6 to 45 kPa, hardnesses from 5 to 50 Shore OOO-S, viscoelastic stress relaxation time constants from 114.1 to 191.9 s, friction forces of 18 gauge needle insertion from 0.005 to 0.086 N/mm, speeds of sound from 1393 to 1407 m/s, acoustic attenuation coefficients from 0.38 to 0.61 (dB/cm)/MHz, T1 relaxation times from 426.3 to 450.2 ms, T2 relaxation times from 21.5 to 28.4 ms, Tλ695 from 46.8% to 92.6%, and Tλ532 from 41.1% to 86.3%. Statistically significant factors of each property were identified. The regression model relating the mechanical and medical imaging properties and their corresponding significant factors had a good fit. The validation tests showed a small discrepancy between the model predicted values and experimental data (all less than 5% except the needle insertion friction force). CONCLUSIONS The regression model developed in this paper can be used to design soft PVC with targeted mechanical and medical imaging properties.
Collapse
Affiliation(s)
- Weisi Li
- School of Mechanical Engineering, Dalian University of Technology, Dalian, Liaoning 110042, China and Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| | - Barry Belmont
- Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| | - Joan M Greve
- Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| | - Adam B Manders
- Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| | - Brian C Downey
- Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| | - Xi Zhang
- Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| | - Zhen Xu
- Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| | - Dongming Guo
- School of Mechanical Engineering, Dalian University of Technology, Dalian, Liaoning 110042, China
| | - Albert Shih
- Mechanical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109 and Biomedical Engineering Department, University of Michigan, Ann Arbor, Michigan 48109
| |
Collapse
|
39
|
Liu CH, Schill A, Wu C, Singh M, Larin KV. Non-contact single shot elastography using line field low coherence holography. BIOMEDICAL OPTICS EXPRESS 2016; 7:3021-31. [PMID: 27570694 PMCID: PMC4986810 DOI: 10.1364/boe.7.003021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2016] [Revised: 06/30/2016] [Accepted: 06/30/2016] [Indexed: 05/18/2023]
Abstract
Optical elastic wave imaging is a powerful technique that can quantify local biomechanical properties of tissues. However, typically long acquisition times make this technique unfeasible for clinical use. Here, we demonstrate non-contact single shot elastographic holography using a line-field interferometer integrated with an air-pulse delivery system. The propagation of the air-pulse induced elastic wave was imaged in real time, and required a single excitation for a line-scan measurement. Results on tissue-mimicking phantoms and chicken breast muscle demonstrated the feasibility of this technique for accurate assessment of tissue biomechanical properties with an acquisition time of a few milliseconds using parallel acquisition.
Collapse
Affiliation(s)
- Chih-Hao Liu
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas 77204, USA
| | - Alexander Schill
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas 77204, USA
| | - Chen Wu
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas 77204, USA
| | - Manmohan Singh
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas 77204, USA
| | - Kirill V. Larin
- Department of Biomedical Engineering, University of Houston, 3605 Cullen Boulevard, Houston, Texas 77204, USA
- Interdisciplinary Laboratory of Biophotonics, Tomsk State University, Tomsk, Russia
- Molecular Physiology and Biophysics, Baylor College of Medicine, One Baylor Plaza, Houston, Texas 77584, USA
| |
Collapse
|
40
|
Ding X, Nguyen MM, James IB, Marra KG, Rubin JP, Leers SA, Kim K. Improved Estimation of Ultrasound Thermal Strain Using Pulse Inversion Harmonic Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:1182-1192. [PMID: 26948260 PMCID: PMC4811719 DOI: 10.1016/j.ultrasmedbio.2016.01.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2015] [Revised: 01/01/2016] [Accepted: 01/13/2016] [Indexed: 06/05/2023]
Abstract
Thermal (temporal) strain imaging (TSI) is being developed to detect the lipid-rich core of atherosclerotic plaques and presence of fatty liver disease. However, the effects of ultrasonic clutter on TSI have not been considered. In this study, we evaluated whether pulse inversion harmonic imaging (PIHI) could be used to improve estimates of thermal (temporal) strain. Using mixed castor oil-gelatin phantoms of different concentrations and artificially introduced clutter, we found that PIHI improved the signal-to-noise ratio of TSI by an average of 213% or 52.1% relative to 3.3- and 6.6-MHz imaging, respectively. In a phantom constructed using human liposuction fat in the presence of clutter, the contrast-to-noise ratio was degraded by 35.1% for PIHI compared with 62.4% and 43.7% for 3.3- and 6.6-MHz imaging, respectively. These findings were further validated using an ex vivo carotid endarterectomy sample. PIHI can be used to improve estimates of thermal (temporal) strain in the presence of clutter.
Collapse
Affiliation(s)
- Xuan Ding
- Department of Bioengineering, University of Pittsburgh School of Engineering, Pittsburgh, Pennsylvania, USA; Medical Scientist Training Program, University of Pittsburgh and Carnegie Mellon University, Pittsburgh, Pennsylvania, USA; Department of Medicine and Heart and Vascular Institute, Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh School of Medicine and University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Man M Nguyen
- Department of Medicine and Heart and Vascular Institute, Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh School of Medicine and University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Isaac B James
- Department of Plastic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Kacey G Marra
- Department of Bioengineering, University of Pittsburgh School of Engineering, Pittsburgh, Pennsylvania, USA; Department of Plastic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh and University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - J Peter Rubin
- Department of Bioengineering, University of Pittsburgh School of Engineering, Pittsburgh, Pennsylvania, USA; Department of Plastic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh and University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Steven A Leers
- Department of Vascular Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
| | - Kang Kim
- Department of Bioengineering, University of Pittsburgh School of Engineering, Pittsburgh, Pennsylvania, USA; Department of Medicine and Heart and Vascular Institute, Center for Ultrasound Molecular Imaging and Therapeutics, University of Pittsburgh School of Medicine and University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA; McGowan Institute for Regenerative Medicine, University of Pittsburgh and University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
| |
Collapse
|
41
|
Bell MAL, Kumar S, Kuo L, Sen HT, Iordachita I, Kazanzides P. Toward Standardized Acoustic Radiation Force (ARF)-Based Ultrasound Elasticity Measurements With Robotic Force Control. IEEE Trans Biomed Eng 2015; 63:1517-24. [PMID: 26552071 DOI: 10.1109/tbme.2015.2497245] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
OBJECTIVE Acoustic radiation force (ARF)-based approaches to measure tissue elasticity require transmission of a focused high-energy acoustic pulse from a stationary ultrasound probe and ultrasound-based tracking of the resulting tissue displacements to obtain stiffness images or shear wave speed estimates. The method has established benefits in biomedical applications such as tumor detection and tissue fibrosis staging. One limitation, however, is the dependence on applied probe pressure, which is difficult to control manually and prohibits standardization of quantitative measurements. To overcome this limitation, we built a robot prototype that controls probe contact forces for shear wave speed quantification. METHODS The robot was evaluated with controlled force increments applied to a tissue-mimicking phantom and in vivo abdominal tissue from three human volunteers. RESULTS The root-mean-square error between the desired and measured forces was 0.07 N in the phantom and higher for the fatty layer of in vivo abdominal tissue. The mean shear wave speeds increased from 3.7 to 4.5 m/s in the phantom and 1.0 to 3.0 m/s in the in vivo fat for compressive forces ranging from 2.5 to 30 N. The standard deviation of shear wave speeds obtained with the robotic approach were low in most cases ( 0.2 m/s) and comparable to that obtained with a semiquantitative landmark-based method. CONCLUSION Results are promising for the introduction of robotic systems to control the applied probe pressure for ARF-based measurements of tissue elasticity. SIGNIFICANCE This approach has potential benefits in longitudinal studies of disease progression, comparative studies between patients, and large-scale multidimensional elasticity imaging.
Collapse
|
42
|
Ahmad A, Huang PC, Sobh NA, Pande P, Kim J, Boppart SA. Mechanical contrast in spectroscopic magnetomotive optical coherence elastography. Phys Med Biol 2015; 60:6655-68. [PMID: 26271056 DOI: 10.1088/0031-9155/60/17/6655] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
The viscoelastic properties of tissues are altered during pathogenesis of numerous diseases and can therefore be a useful indicator of disease status and progression. Several elastography studies have utilized the mechanical frequency response and the resonance frequencies of tissue samples to characterize their mechanical properties. However, using the resonance frequency as a source of mechanical contrast in heterogeneous samples is complicated because it not only depends on the viscoelastic properties but also on the geometry and boundary conditions. In an elastography technique called magnetomotive optical coherence elastography (MM-OCE), the controlled movement of magnetic nanoparticles (MNPs) within the sample is used to obtain the mechanical properties. Previous demonstrations of MM-OCE have typically used point measurements in elastically homogeneous samples assuming a uniform concentration of MNPs. In this study, we evaluate the feasibility of generating MM-OCE elastograms in heterogeneous samples based on a spectroscopic approach which involves measuring the magnetomotive response at different excitation frequencies. Biological tissues and tissue-mimicking phantoms with two elastically distinct regions placed in side-by-side and bilayer configurations were used for the experiments, and finite element method simulations were used to validate the experimental results.
Collapse
Affiliation(s)
- Adeel Ahmad
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana IL 61801, USA. Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 306 North Wright Street, Urbana IL 61801, USA
| | | | | | | | | | | |
Collapse
|
43
|
Zhu Y, Dong C, Yin Y, Chen X, Guo Y, Zheng Y, Shen Y, Wang T, Zhang X, Chen S. The role of viscosity estimation for oil-in-gelatin phantom in shear wave based ultrasound elastography. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:601-9. [PMID: 25542484 DOI: 10.1016/j.ultrasmedbio.2014.09.028] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/10/2014] [Revised: 09/16/2014] [Accepted: 09/21/2014] [Indexed: 05/04/2023]
Abstract
Shear wave based ultrasound elastography utilizes mechanical excitation or acoustic radiation force to induce shear waves in deep tissue. The tissue response is monitored to obtain elasticity information about the tissue. During the past two decades, tissue elasticity has been extensively studied and has been used in clinical disease diagnosis. However, biological soft tissues are viscoelastic in nature. Therefore, they should be simultaneously characterized in terms of elasticity and viscosity. In this study, two shear wave-based elasticity imaging methods, shear wave dispersion ultrasound vibrometry (SDUV) and acoustic radiation force impulsive (ARFI) imaging, were compared. The discrepancy between the measurements obtained by the two methods was analyzed, and the role of viscosity was investigated. To this end, four types of gelatin phantoms containing 0%, 20%, 30% and 40% castor oil were fabricated to mimic different viscosities of soft tissue. For the SDUV method, the shear elasticity μ1 was 3.90 ± 0.27 kPa, 4.49 ± 0.16 kPa, 2.41 ± 0.33 kPa and 1.31 ± 0.09 kPa; and the shear viscosity μ2 was 1.82 ± 0.31 Pa•s, 2.41 ± 0.35 Pa•s, 2.65 ± 0.13 Pa•s and 2.89 ± 0.14 Pa•s for 0%, 20%, 30% and 40% oil, respectively in both cases. For the ARFI measurements, the shear elasticity μ was 7.30 ± 0.20 kPa, 8.20 ± 0.31 kPa, 7.42 ± 0.21 kPa and 5.90 ± 0.36 kPa for 0%, 20%, 30% and 40% oil, respectively. The SDUV results demonstrated that the elasticity first increased from 0% to 20% oil and then decreased for the 30% and 40% oil. The viscosity decreased consistently as the concentration of castor oil increased from 0% to 40%. The elasticity measured by ARFI showed the same trend as that of the SDUV but exceeded the results measured by SDUV. To clearly validate the impact of viscosity on the elasticity estimation, an independent measurement of the elasticity and viscosity by dynamic mechanical analysis (DMA) was conducted on these four types of gelatin phantoms and then compared with SDUV and ARFI results. The shear elasticities obtained by DMA (3.44 ± 0.31 kPa, 4.29 ± 0.13 kPa, 2.05 ± 0.29 kPa and 1.06 ± 0.18 kPa for 0%, 20%, 30% and 40% oil, respectively) were lower than those by SDUV, whereas the shear viscosities obtained by DMA (2.52 ± 0.32 Pa·s, 3.18 ± 0.12 Pa·s, 3.98 ± 0.19 Pa·s and 4.90 ± 0.20 Pa·s for 0%, 20%, 30% and 40% oil, respectively) were greater than those obtained by SDUV. However, the DMA results showed that the trend in the elasticity and viscosity data was the same as that obtained from the SDUV and ARFI. The SDUV results demonstrated that adding castor oil changed the viscoelastic properties of the phantoms and resulted in increased dispersion of the shear waves. Viscosity can provide important and independent information about the inner state of the phantoms, in addition to the elasticity. Because the ARFI method ignores the dispersion of the shear waves, namely viscosity, it may bias the estimation of the true elasticity. This study sheds further light on the significance of the viscosity measurements in shear wave based elasticity imaging methods.
Collapse
Affiliation(s)
- Ying Zhu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China
| | - Changfeng Dong
- Department of Ultrasonography, The Third People's Hospital of Shenzhen, Shenzhen, China
| | - Yin Yin
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China
| | - Xin Chen
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China
| | - Yanrong Guo
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China
| | - Yi Zheng
- Department of Electrical and Computer Engineering, St. Cloud State University, St. Cloud, MN, USA
| | - Yuanyuan Shen
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China
| | - Tianfu Wang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China
| | - Xinyu Zhang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China.
| | - Siping Chen
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Department of Biomedical Engineering, School of Medicine, Shenzhen University, Shenzhen, China.
| |
Collapse
|
44
|
Chatelin S, Bernal M, Deffieux T, Papadacci C, Flaud P, Nahas A, Boccara C, Gennisson JL, Tanter M, Pernot M. Anisotropic polyvinyl alcohol hydrogel phantom for shear wave elastography in fibrous biological soft tissue: a multimodality characterization. Phys Med Biol 2014; 59:6923-40. [PMID: 25350315 DOI: 10.1088/0031-9155/59/22/6923] [Citation(s) in RCA: 46] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Shear wave elastography imaging techniques provide quantitative measurement of soft tissues elastic properties. Tendons, muscles and cerebral tissues are composed of fibers, which induce a strong anisotropic effect on the mechanical behavior. Currently, these tissues cannot be accurately represented by existing elastography phantoms. Recently, a novel approach for orthotropic hydrogel mimicking soft tissues has been developed (Millon et al 2006 J. Biomed. Mater. Res. B 305-11). The mechanical anisotropy is induced in a polyvinyl alcohol (PVA) cryogel by stretching the physical crosslinks of the polymeric chains while undergoing freeze/thaw cycles. In the present study we propose an original multimodality imaging characterization of this new transverse isotropic (TI) PVA hydrogel. Multiple properties were investigated using a large variety of techniques at different scales compared with an isotropic PVA hydrogel undergoing similar imaging and rheology protocols. The anisotropic mechanical (dynamic and static) properties were studied using supersonic shear wave imaging technique, full-field optical coherence tomography (FFOCT) strain imaging and classical linear rheometry using dynamic mechanical analysis. The anisotropic optical and ultrasonic spatial coherence properties were measured by FFOCT volumetric imaging and backscatter tensor imaging, respectively. Correlation of mechanical and optical properties demonstrates the complementarity of these techniques for the study of anisotropy on a multi-scale range as well as the potential of this TI phantom as fibrous tissue-mimicking phantom for shear wave elastographic applications.
Collapse
Affiliation(s)
- Simon Chatelin
- Institut Langevin, ESPCI ParisTech, PSL Research University, UMR 7587 CNRS, U979 INSERM, Paris, France
| | | | | | | | | | | | | | | | | | | |
Collapse
|
45
|
Ahmad A, Kim J, Sobh NA, Shemonski ND, Boppart SA. Magnetomotive optical coherence elastography using magnetic particles to induce mechanical waves. BIOMEDICAL OPTICS EXPRESS 2014; 5:2349-61. [PMID: 25071969 PMCID: PMC4102369 DOI: 10.1364/boe.5.002349] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2014] [Revised: 06/09/2014] [Accepted: 06/11/2014] [Indexed: 05/08/2023]
Abstract
Magnetic particles are versatile imaging agents that have found wide spread applicability in diagnostic, therapeutic, and rheology applications. In this study, we demonstrate that mechanical waves generated by a localized inclusion of magnetic nanoparticles can be used for assessment of the tissue viscoelastic properties using magnetomotive optical coherence elastography. We show these capabilities in tissue mimicking elastic and viscoelastic phantoms and in biological tissues by measuring the shear wave speed under magnetomotive excitation. Furthermore, we demonstrate the extraction of the complex shear modulus by measuring the shear wave speed at different frequencies and fitting to a Kelvin-Voigt model.
Collapse
Affiliation(s)
- Adeel Ahmad
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, IL, 61801 USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green St, Urbana, Illinois 61801, USA
| | - Jongsik Kim
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, IL, 61801 USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green St, Urbana, Illinois 61801, USA
| | - Nahil A. Sobh
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, IL, 61801 USA
- Department of Civil and Environmental Engineering, University of Illinois at Urbana-Champaign, 205 North Mathews Ave, Urbana, Illinois 61801, USA
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, 1206 West Green St, Urbana, Illinois 61801, USA
| | - Nathan D. Shemonski
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, IL, 61801 USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green St, Urbana, Illinois 61801, USA
| | - Stephen A. Boppart
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Avenue, Urbana, IL, 61801 USA
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 1406 West Green St, Urbana, Illinois 61801, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, 1304 West Springfield Avenue, Urbana, Illinois 61801, USA
- Department of Internal Medicine, University of Illinois at Urbana-Champaign, 506 South Mathews Ave, Urbana, Illinois 61801, USA
| |
Collapse
|