1
|
Bouffandeau A, Poudrel AS, Brossier C, Rosi G, Nguyen VH, Flouzat-Lachaniette CH, Meningaud JP, Haïat G. Assessment of the Mechanical Properties of Soft Tissue Phantoms Using Impact Analysis. SENSORS (BASEL, SWITZERLAND) 2025; 25:1344. [PMID: 40096164 PMCID: PMC11902684 DOI: 10.3390/s25051344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2024] [Revised: 02/06/2025] [Accepted: 02/20/2025] [Indexed: 03/19/2025]
Abstract
Skin physiopathological conditions have a strong influence on its biomechanical properties. However, it remains difficult to accurately assess the surface stiffness of soft tissues. The aim of this study was to evaluate the performances of an impact-based analysis method (IBAM) and to compare them with those of an existing digital palpation device, MyotonPro®. The IBAM is based on the impact of an instrumented hammer equipped with a force sensor on a cylindrical punch in contact with agar-based phantoms mimicking soft tissues. The indicator Δt is estimated by analyzing the force signal obtained from the instrumented hammer. Various phantom geometries, stiffnesses and structures (homogeneous and bilayer) were used to estimate the performances of both methods. Measurements show that the IBAM is sensitive to a volume of interest equivalent to a sphere approximately twice the punch diameter. The sensitivity of the IBAM to changes in Young's modulus is similar to that of dynamic mechanical analysis (DMA) and significantly better compared to MyotonPro. The axial (respectively, lateral) resolution is two (respectively, five) times lower with the IBAM than with MyotonPro. The present study paves the way for the development of a simple, quantitative and non-invasive method to measure skin biomechanical properties.
Collapse
Affiliation(s)
- Arthur Bouffandeau
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| | - Anne-Sophie Poudrel
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| | - Chloé Brossier
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| | - Giuseppe Rosi
- Laboratoire Modélisation et Simulation Multi Echelle, Université Paris Est Créteil, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France
| | - Vu-Hieu Nguyen
- Laboratoire Modélisation et Simulation Multi Echelle, Université Paris Est Créteil, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France
| | - Charles-Henri Flouzat-Lachaniette
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, Laboratoire IMRB INSERM U955—Université Paris—Est Créteil, 8 rue du Général Sarrail, 94010 Créteil, France;
| | - Jean-Paul Meningaud
- Service de Chirurgie Plastique, Reconstructrice, Esthétique et Maxillo-Faciale, Hôpital Henri Mondor AP-HP, Laboratoire IMRB INSERM U955—Université Paris—Est Créteil, 8 rue du Général Sarrail, 94010 Créteil, France
| | - Guillaume Haïat
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| |
Collapse
|
2
|
Poudrel AS, Bouffandeau A, Demeet OL, Rosi G, Nguyen VH, Haiat G. Characterization of the concentration of agar-based soft tissue mimicking phantoms by impact analysis. J Mech Behav Biomed Mater 2024; 152:106465. [PMID: 38377641 DOI: 10.1016/j.jmbbm.2024.106465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 01/14/2024] [Accepted: 02/13/2024] [Indexed: 02/22/2024]
Abstract
In various medical fields, a change of soft tissue stiffness is associated with its physio-pathological evolution. While elastography is extensively employed to assess soft tissue stiffness in vivo, its application requires a complex and expensive technology. The aim of this study is to determine whether an easy-to-use method based on impact analysis can be employed to determine the concentration of agar-based soft tissue mimicking phantoms. Impact analysis was performed on soft tissue mimicking phantoms made of agar gel with a mass concentration ranging from 1% to 5%. An indicator Δt is derived from the temporal variation of the impact force signal between the hammer and a small beam in contact with the sample. The results show a non-linear decrease of Δt as a function of the agar concentration (and thus of the sample stiffness). The value of Δt provides an estimation of the agar concentration with an error of 0.11%. This sensitivity of the impact analysis based method to the agar concentration is of the same order of magnitude than results obtained with elastography techniques. This study opens new paths towards the development of impact analysis for a fast, easy and relatively inexpensive clinical evaluation of soft tissue elastic properties.
Collapse
Affiliation(s)
- Anne-Sophie Poudrel
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Arthur Bouffandeau
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Oriane Le Demeet
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Vu-Hieu Nguyen
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Guillaume Haiat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France.
| |
Collapse
|
3
|
Rodriguez Betancourt A, Samal A, Chan HL, Kripfgans OD. Overview of Ultrasound in Dentistry for Advancing Research Methodology and Patient Care Quality with Emphasis on Periodontal/Peri-implant Applications. Z Med Phys 2023; 33:336-386. [PMID: 36922293 PMCID: PMC10517409 DOI: 10.1016/j.zemedi.2023.01.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2022] [Revised: 12/20/2022] [Accepted: 01/11/2023] [Indexed: 03/14/2023]
Abstract
BACKGROUND Ultrasound is a non-invasive, cross-sectional imaging technique emerging in dentistry. It is an adjunct tool for diagnosing pathologies in the oral cavity that overcomes some limitations of current methodologies, including direct clinical examination, 2D radiographs, and cone beam computerized tomography. Increasing demand for soft tissue imaging has led to continuous improvements on transducer miniaturization and spatial resolution. The aims of this study are (1) to create a comprehensive overview of the current literature of ultrasonic imaging relating to dentistry, and (2) to provide a view onto investigations with immediate, intermediate, and long-term impact in periodontology and implantology. METHODS A rapid literature review was performed using two broad searches conducted in the PubMed database, yielding 576 and 757 citations, respectively. A rating was established within a citation software (EndNote) using a 5-star classification. The broad search with 757 citations allowed for high sensitivity whereas the subsequent rating added specificity. RESULTS A critical review of the clinical applications of ultrasound in dentistry was provided with a focus on applications in periodontology and implantology. The role of ultrasound as a developing dental diagnostic tool was reviewed. Specific uses such as soft and hard tissue imaging, longitudinal monitoring, as well as anatomic and physiological evaluation were discussed. CONCLUSIONS Future efforts should be directed towards the transition of ultrasonography from a research tool to a clinical tool. Moreover, a dedicated effort is needed to introduce ultrasonic imaging to dental education and the dental community to ultimately improve the quality of patient care.
Collapse
Affiliation(s)
| | - Ankita Samal
- Department of Radiology, Medical School, University of Michigan, Ann Arbor, MI, USA
| | - Hsun-Liang Chan
- Department of Periodontology and Oral Medicine, Dental School, University of Michigan, Ann Arbor, MI, USA
| | - Oliver D Kripfgans
- Department of Radiology, Medical School, University of Michigan, Ann Arbor, MI, USA
| |
Collapse
|
4
|
Hériveaux Y, Nguyen VH, Haïat G. Ultrasonic Evaluation of the Bone-Implant Interface. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:373-396. [DOI: 10.1007/978-3-030-91979-5_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
5
|
Hériveaux Y, Vayron R, Fraulob M, Lomami HA, Lenormand C, Haïat G. Assessment of dental implant stability using resonance frequency analysis and quantitative ultrasound methods. J Prosthodont Res 2021; 65:421-427. [PMID: 33177307 DOI: 10.2186/jpr.jpr_d_20_00052] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Purpose Quantitative ultrasound (QUS) and resonance frequency analyses (RFA) are promising methods to assess the stability of dental implants. The aim of this in vivo preclinical study is to compare the results obtained with these two techniques with the bone-implant contact (BIC) ratio, which is the gold standard to assess dental implant stability.Methods Twenty-two identical dental implants were inserted in the tibia and femur of 12 rabbits, which were sacrificed after different healing durations (0, 4, 8 and 13 weeks). For each implant, the ultrasonic indicator (UI) and the implant stability quotient (ISQ) were retrieved just before the animal sacrifice using the QUS and RFA techniques, respectively. Histomorphometric analyses were carried out to estimate the bone-implant contact ratio.Results UI values were found to be better correlated to BIC values (R²=0.47) compared to ISQ values (R²=0.39 for measurements in one direction and R²=0.18 for the other direction), which were shown to be dependent on the direction of measurements. Errors realized on the UI were around 3.3 times lower to the ones realized on the ISQ.Conclusions QUS provide a better estimation of dental implant stability compared to RFA. This study paves the way for the future clinical development of a medical device aiming at assessing dental implant stability in a patient-specific manner. Clinical studies should confirm these results in the future.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Romain Vayron
- Université Polytechnique des Hauts de France, Laboratoire d'Automatique, de Mécanique et d'informatique Industrielles et Humaines, Valenciennes, France
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Hugues Albini Lomami
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Camille Lenormand
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, Créteil Cedex, France
| |
Collapse
|
6
|
Kwak Y, Nguyen VH, Hériveaux Y, Belanger P, Park J, Haïat G. Ultrasonic assessment of osseointegration phenomena at the bone-implant interface using convolutional neural network. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:4337. [PMID: 34241416 DOI: 10.1121/10.0005272] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 05/21/2021] [Indexed: 06/13/2023]
Abstract
Although endosseous implants are widely used in the clinic, failures still occur and their clinical performance depends on the quality of osseointegration phenomena at the bone-implant interface (BII), which are given by bone ingrowth around the BII. The difficulties in ensuring clinical reliability come from the complex nature of this interphase related to the implant surface roughness and the presence of a soft tissue layer (non-mineralized bone tissue) at the BII. The aim of the present study is to develop a method to assess the soft tissue thickness at the BII based on the analysis of its ultrasonic response using a simulation based-convolution neural network (CNN). A large-annotated dataset was constructed using a two-dimensional finite element model in the frequency domain considering a sinusoidal description of the BII. The proposed network was trained by the synthesized ultrasound responses and was validated by a separate dataset from the training process. The linear correlation between actual and estimated soft tissue thickness shows excellent R2 values equal to 99.52% and 99.65% and a narrow limit of agreement corresponding to [ -2.56, 4.32 μm] and [ -15.75, 30.35 μm] of microscopic and macroscopic roughness, respectively, supporting the reliability of the proposed assessment of osseointegration phenomena.
Collapse
Affiliation(s)
- Yunsang Kwak
- Centre National de la Recherche Scientifique, MSME, Université Paris-Est Créteil, Université Gustave Eiffel, F-94010 Creteil, France
| | - Vu-Hieu Nguyen
- University of Paris Est Creteil, Centre National de la Recherche Scientifique, Multiscale Simulation and Modeling Laboratory, F-94010 Creteil, France
| | - Yoann Hériveaux
- Centre National de la Recherche Scientifique, MSME, Université Paris-Est Créteil, Université Gustave Eiffel, F-94010 Creteil, France
| | - Pierre Belanger
- Department of Mechanical Engineering, École de Technologie Supérieure, 1100 Rue Notre-Dame O, Montreal, Quebec, H3C 1K3, Canada
| | - Junhong Park
- Department of Mechanical Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, 04763 Seoul, South Korea
| | - Guillaume Haïat
- Centre National de la Recherche Scientifique, MSME, Université Paris-Est Créteil, Université Gustave Eiffel, F-94010 Creteil, France
| |
Collapse
|
7
|
Hériveaux Y, Nguyen VH, Biwa S, Haïat G. Analytical modeling of the interaction of an ultrasonic wave with a rough bone-implant interface. ULTRASONICS 2020; 108:106223. [PMID: 32771811 DOI: 10.1016/j.ultras.2020.106223] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 04/09/2020] [Accepted: 04/15/2020] [Indexed: 06/11/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The determination of the constitutive law of the BII would be of interest in the context of implant acoustical modeling in order to take into account the imperfect characteristics of the BII. The aim of the present study is to propose an analytical effective model describing the interaction between an ultrasonic wave and a rough BII. To do so, a spring model was considered to determine the equivalent stiffness K of the BII. The stiffness contributions related (i) to the partial contact between the bone and the implant and (ii) to the presence of soft tissues at the BII during the process of osseointegration were assessed independently. K was found to be comprised between 1013 and 1017 N/m3 depending on the roughness and osseointegration of the BII. Analytical values of the reflection and transmission coefficients at the BII were derived from values of K. A good agreement with numerical results obtained through finite element simulation was obtained. This model may be used for future finite element bone-implant models to replace the BII conditions.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, Créteil Cedex 94010, France
| | - Shiro Biwa
- Department of Aeronautics and Astronautics, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8540, Japan
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France.
| |
Collapse
|
8
|
Effect of bone quality and quantity on the primary stability of dental implants in a simulated bicortical placement. Clin Oral Investig 2020; 25:1265-1272. [PMID: 32651646 PMCID: PMC7878229 DOI: 10.1007/s00784-020-03432-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2019] [Accepted: 06/24/2020] [Indexed: 12/20/2022]
Abstract
OBJECTIVES Conventional dental implants inserted in the molar region of the maxilla will reach into the sinus maxillaris when alveolar ridge height is limited. When surgery is performed without prior augmentation of the sinus floor, primary stability of the implant is important for successful osseointegration. This study aimed at identifying the impact of bone quality and quantity at the implantation site on primary implant stability of a simulated bicortical placement. MATERIALS AND METHODS In our in vitro measurements, bone mineral density, total bone thickness and overall cortical bone thickness were assessed by micro-computed tomography (μCT) of pig scapulae, which resembled well the bicortical situation found in human patients. Dental implants were inserted, and micromotion between bone and implant was measured while loading the implant with an axial torque. RESULTS The main findings were that primary implant stability did not depend on total bone thickness but tended to increase with either increasing bone mineral density or overall cortical bone thickness. CLINICAL RELEVANCE Limited bone height in the maxilla is a major problem when planning dental implants. To overcome this problem, several approaches, e.g. external or internal sinus floor elevation, have been established. When planning the insertion of a dental implant an important aspect is the primary stability which can be expected. With other factors, the dimensions of the cortical bone might be relevant in this context. It would, therefore, be helpful to define the minimum thickness of cortical bone required to achieve sufficient primary stability, thus avoiding additional surgical intervention.
Collapse
|
9
|
Hériveaux Y, Audoin B, Biateau C, Nguyen VH, Haïat G. Ultrasonic Propagation in a Dental Implant. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:1464-1473. [PMID: 32139153 DOI: 10.1016/j.ultrasmedbio.2020.01.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 12/23/2019] [Accepted: 01/23/2020] [Indexed: 06/10/2023]
Abstract
Ultrasound techniques can be used to characterize and stimulate dental implant osseointegration. However, the interaction between an ultrasonic wave and the implant-bone interface (IBI) remains unclear. This study-combining experimental and numerical approaches-investigates the propagation of an ultrasonic wave in a dental implant by assessing the amplitude of the displacements along the implant axis. An ultrasonic transducer was excited in a transient regime at 10 MHz. Laser interferometric techniques were employed to measure the amplitude of the displacements, which varied 3.2-8.9 nm along the implant axis. The results demonstrated the propagation of a guided wave mode along the implant axis. The velocity of the first arriving signal was equal to 2110 m.s-1, with frequency components lower than 1 MHz, in agreement with numerical results. Investigating guided wave propagation in dental implants should contribute to improved methods for the characterization and stimulation of the IBI.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| | - Bertrand Audoin
- CNRS, Institut de Mécanique et d'Ingénierie, Talence, France
| | | | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, Créteil, France
| |
Collapse
|
10
|
Modeling ultrasonic wave propagation in a dental implant - Bone system. J Mech Behav Biomed Mater 2019; 103:103547. [PMID: 31778910 DOI: 10.1016/j.jmbbm.2019.103547] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 09/04/2019] [Accepted: 11/19/2019] [Indexed: 02/05/2023]
Abstract
The evolution of the bone-implant interface reflects the implant osseointegration and bond strength, thereby determining the overall implant stability in the jawbone. Quantitative ultrasound represents a promising alternative technique to characterize the interfacial integrity, precisely due to the fact that those waves propagate essentially along the bone-implant interface, and are therefore influenced by its state. This study reports a numerical investigation of ultrasonic wave propagation for a commercial implant-jawbone system in which the thickness and mechanical properties of the interfacial layer (corresponding to the interphase) are systematically varied through the application of a rule of mixtures, in order to mimic the evolution from a dominantly soft tissue - like medium up to a fully healed bone. A simple figure of merit is devised in terms of an RMS-like (root mean square) factor based on the implant displacements, that evolves continuously and significantly with the bone "healing" process, thereby providing unequivocal information on the nature of the investigated bone-implant interface. The results show that the wave propagation pattern is primarily dictated by the impedance mismatch rather than by the interface thickness. This study validates the concept of quantitative ultrasonic testing as a sensitive alternative to the widespread resonant frequency analysis, thereby opening the way for future sensitivity analyses that will address more refined bone-implant interface pathologies such as those observed in the clinical realm.
Collapse
|
11
|
Hériveaux Y, Nguyen VH, Geiger D, Haïat G. Elastography of the bone-implant interface. Sci Rep 2019; 9:14163. [PMID: 31578440 PMCID: PMC6775155 DOI: 10.1038/s41598-019-50665-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 09/17/2019] [Indexed: 01/04/2023] Open
Abstract
The stress distribution around endosseous implants is an important determinant of the surgical success. However, no method developed so far to determine the implant stability is sensitive to the loading conditions of the bone-implant interface (BII). The objective of this study is to investigate whether a quantitative ultrasound (QUS) technique may be used to retrieve information on compressive stresses applied to the BII. An acousto-mechanical device was conceived to compress 18 trabecular bovine bone samples onto coin-shaped implants and to measure the ultrasonic response of the BII during compression. The biomechanical behavior of the trabecular bone samples was modeled as Neo-Hookean. The reflection coefficient of the BII was shown to decrease as a function of the stress during the elastic compression of the trabecular bone samples and during the collapse of the trabecular network, with an average slope of −4.82 GPa−1. The results may be explained by an increase of the bone-implant contact ratio and by changes of bone structure occurring during compression. The sensitivity of the QUS response of the BII to compressive stresses opens new paths in the elaboration of patient specific decision support systems allowing surgeons to assess implant stability that should be developed in the future.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Didier Geiger
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France.
| |
Collapse
|
12
|
Rizzo P. A review on the latest advancements in the non-invasive evaluation/monitoring of dental and trans-femoral implants. Biomed Eng Lett 2019; 10:83-102. [PMID: 32175131 DOI: 10.1007/s13534-019-00126-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Revised: 06/05/2019] [Accepted: 07/29/2019] [Indexed: 12/11/2022] Open
Abstract
Dental implants and transcutaneous prostheses (trans-femoral implants) improve the quality of life of millions of people because they represent the optimal treatments to edentulism and amputation, respectively. The clinical procedures adopted by surgeons to insert these implants are well established. However, there is uncertainty on the outcomes of the post-operation recovery because of the uncertainty associated with the osseointegration process, which is defined as the direct, structural and functional contact between the living bone and the fixture. To guarantee the long-term survivability of dental or trans-femoral implants doctors sometimes implement non-invasive techniques to monitor and evaluate the progress of osseointegration. This may be done by measuring the stability of the fixture or by assessing the quality of the bone-fixture interface. In addition, care providers may need to quantify the structural integrity of the bone-implant system at various moments during the patients recovery. The accuracy of such non-invasive methods reduce recovery and rehabilitation time, and may increase the survival rate of the therapies with undisputable benefits for the patients. This paper provides a comprehensive review of clinically-approved and emerging non-invasive methods to evaluate/monitor the osseointegration of dental and orthopedic implants. A discussion about advantages and limitations of each method is provided based on the outcomes of the cases presented. The review on the emerging technologies covers the developments of the last decade, while the discussion about the clinically approved systems focuses mostly on the latest (2017-2018) findings. At last, the review also provides some suggestions for future researches and developments in the area of implant monitoring.
Collapse
Affiliation(s)
- Piervincenzo Rizzo
- Department of Civil and Environmental Engineering, University of Pittsburgh, 729 Benedum Hall, 3700 O'Hara Street, Pittsburgh, PA 15261 USA
| |
Collapse
|
13
|
Non-radiative healing assessment techniques for fractured long bones and osseointegrated implant. Biomed Eng Lett 2019; 10:63-81. [PMID: 32175130 DOI: 10.1007/s13534-019-00120-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 07/04/2019] [Accepted: 07/12/2019] [Indexed: 01/08/2023] Open
Abstract
The paper provides an overview of the fracture healing process of long bones, a review of work that proposed appropriate physical parameters for the assessment of healing and highlights some recent work that reported on the development of non-radiative technique for healing assessment. An overview of the development and monitoring of osseointegration for trans-femoral osseointegrated implant is also presented. The state of healing of a fractured long bone and the stability of osseointegrated implants can be seen as engineering structural components where the mechanical properties are restored to facilitate their desired function. To this end, this paper describes non-radiative techniques that are useful for healing assessment and the stability assessment of osseointegrated implants. The achievement of non-radiative quantitative assessment methodologies to determine the state of healing of fractured long bones and to assess the stability of osseointegrated implant will shorten the patient's rehabilitation time, allowing earlier mobility and return to normal activities. Recent work on the development of assessment techniques supported by the Office of Naval Research as part of the Monitoring of Osseointegrated Implant Prosthesis program is highlighted.
Collapse
|
14
|
Hériveaux Y, Nguyen VH, Brailovski V, Gorny C, Haïat G. Reflection of an ultrasonic wave on the bone-implant interface: Effect of the roughness parameters. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2019; 145:3370. [PMID: 31255165 DOI: 10.1121/1.5109668] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 05/10/2019] [Indexed: 06/09/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The aim of this study is to derive the main determinants of the ultrasonic response of the BII during osseointegration phenomena. The influence of (i) the surface roughness parameters and (ii) the thickness W of a soft tissue layer on the reflection coefficient r of the BII was investigated using a two-dimensional finite element model. When W increases from 0 to 150 μm, r increases from values in the range [0.45; 0.55] to values in the range [0.75; 0.88] according to the roughness parameters. An optimization method was developed to determine the sinusoidal roughness profile leading to the most similar ultrasonic response for all values of W compared to the original profile. The results show that the difference between the ultrasonic responses of the optimal sinusoidal profile and of the original profile was lower to typical experimental errors. This approach provides a better understanding of the ultrasonic response of the BII, which may be used in future numerical simulation realized at the scale of an implant.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vladimir Brailovski
- Department of Mechanical Engineering, École de technologie supérieure, 1100 Notre-Dame Street West, Montreal, Quebec H3C 1K3, Canada
| | - Cyril Gorny
- Laboratoire PIMM (ENSAM, CNRS, CNAM, Hesam Université), 151 Bd de l'Hôpital 75013 Paris (ENSAM), France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
15
|
Rittel D, Dorogoy A, Haïat G, Shemtov-Yona K. Resonant frequency analysis of dental implants. Med Eng Phys 2019; 66:65-74. [PMID: 30837120 DOI: 10.1016/j.medengphy.2019.02.008] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2018] [Revised: 12/14/2018] [Accepted: 02/17/2019] [Indexed: 12/29/2022]
Abstract
Dental implant stability influences the decision on the determination of the duration between implant insertion and loading. This work investigates the resonant frequency analysis by means of a numerical model. The investigation is done numerically through the determination of the eigenfrequencies and performing steady state response analyses using a commercial finite element package. A peri-implant interface, of simultaneously varying stiffness, density and layer thickness is introduced in the numerical 3D model in order to probe the sensitivity of the eigenfrequencies and steady state response to an evolving weakened layer, in an attempt to identify the bone reconstruction around the implant. For the first two modes, the resonant frequency is somewhat insensitive to the healing process, unless the weakened layer is rather large and compliant, like in the very early stages of the implantation. A "Normalized Healing Factor" is devised in the spirit of the Implant Stability Quotient, which can identify the healing process especially at the early stages after implantation. The sensitivity of the resonant frequency analysis to changes of mechanical properties of periprosthetic bone tissue seems relatively weak. Another indicator considering the amplitude as well as the resonance frequency might be more adapted to bone healing estimations. However, these results need to be verified experimentally as well as clinically.
Collapse
Affiliation(s)
- D Rittel
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel.
| | - A Dorogoy
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
| | - G Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-échelle, UMR CNRS 8202, 94010 Créteil Cedex, France
| | - K Shemtov-Yona
- Faculty of Mechanical Engineering, Technion, 32000 Haifa, Israel
| |
Collapse
|
16
|
Zanetti EM, Pascoletti G, Calì M, Bignardi C, Franceschini G. Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives. BIOSENSORS 2018; 8:E68. [PMID: 30011870 PMCID: PMC6165397 DOI: 10.3390/bios8030068] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 07/09/2018] [Accepted: 07/11/2018] [Indexed: 01/02/2023]
Abstract
The optimization of loading protocols following dental implant insertion requires setting up patient-specific protocols, customized according to the actual implant osseointegration, measured through quantitative, objective methods. Various devices for the assessment of implant stability as an indirect measure of implant osseointegration have been developed. They are analyzed here, introducing the respective physical models, outlining major advantages and critical aspects, and reporting their clinical performance. A careful discussion of underlying hypotheses is finally reported, as is a suggestion for further development of instrumentation and signal analysis.
Collapse
|
17
|
Hériveaux Y, Nguyen VH, Haïat G. Reflection of an ultrasonic wave on the bone-implant interface: A numerical study of the effect of the multiscale roughness. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2018; 144:488. [PMID: 30075648 DOI: 10.1121/1.5046524] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 06/28/2018] [Indexed: 06/08/2023]
Abstract
Quantitative ultrasound is used to characterize and stimulate osseointegration processes at the bone-implant interface (BII). However, the interaction between an ultrasonic wave and the implant remains poorly understood. This study aims at investigating the sensitivity of the ultrasonic response to the microscopic and macroscopic properties of the BII and to osseointegration processes. The reflection coefficient R of the BII was modeled for different frequencies using a two-dimensional finite element model. The implant surface roughness was modeled by a sinusoidal function with varying amplitude h and spatial frequency L. A soft tissue layer of thickness W was considered between bone tissue and the implant in order to model non-mineralized fibrous tissue. For microscopic roughness, R is shown to increase from around 0.55 until 0.9 when kW increases from 0 to 1 and to be constant for kW > 1, where k is the wavenumber in the implant. These results allow us to show that R depends on the properties of bone tissue located at a distance comprised between 1 and 25 μm from the implant surface. For macroscopic roughness, R is highly dependent on h and this dependence may be explained by phase cancellation and multiple scattering effects for high roughness parameters.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
18
|
Bhaskar V, Chan HL, MacEachern M, Kripfgans OD. Updates on ultrasound research in implant dentistry: a systematic review of potential clinical indications. Dentomaxillofac Radiol 2018; 47:20180076. [PMID: 29791198 DOI: 10.1259/dmfr.20180076] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
OBJECTIVES Ultrasonography has shown promising diagnostic value in dental implant imaging research; however, exactly how ultrasound was used and at what stage of implant therapy it can be applied has not been systematically evaluated. Therefore, the aim of this review is to investigate potential indications of ultrasound use in the three implant treatment phases, namely planning, intraoperative and post-operative phase. METHODS Eligible manuscripts were searched in major databases with a combination of keywords related to the use of ultrasound imaging in implant therapy. An initial search yielded 414 articles, after further review, 28 articles were finally included for this systematic review. RESULTS Ultrasound was found valuable, though at various development stages, for evaluating (1) soft tissues, (2) hard tissues (3) vital structures and (4) implant stability. B-mode, the main function to image anatomical structures of interest, has been evaluated in pre-clinical and clinical studies. Quantitative ultrasound parameters, e.g. sound speed and amplitude, are being developed to evaluate implant-bone stability, mainly in simulation and pre-clinical studies. Ultrasound could be potentially useful in all three treatment phases. In the planning phase, ultrasound could evaluate vital structures, tissue biotype, ridge width/density, and cortical bone thickness. During surgery, it can provide feedback by identifying vital structures and bone boundary. At follow-up visits, it could evaluate marginal bone level and implant stability. CONCLUSIONS Understanding the current status of ultrasound imaging research for implant therapy would be extremely beneficial for accelerating translational research and its use in dental clinics.
Collapse
Affiliation(s)
| | - Hsun-Liang Chan
- 2 Department of Periodontics and Oral Medicine, University of Michigan School of Dentistry , Ann Arbor, MI , USA
| | - Mark MacEachern
- 3 Taubman Health Sciences Library, University of Michigan , Ann Arbor, MI , USA
| | - Oliver D Kripfgans
- 4 Department of Biomedical Engineering, College of Engineering , Ann Arbor, MI , USA.,5 Department of Radiology, University of Michigan Medical School , Ann Arbor, MI , USA
| |
Collapse
|
19
|
Bosc R, Tijou A, Rosi G, Nguyen VH, Meningaud JP, Hernigou P, Flouzat-Lachaniette CH, Haiat G. Influence of soft tissue in the assessment of the primary fixation of acetabular cup implants using impact analyses. Clin Biomech (Bristol, Avon) 2018; 55:7-13. [PMID: 29625357 DOI: 10.1016/j.clinbiomech.2018.03.013] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Revised: 02/08/2018] [Accepted: 03/19/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND The acetabular cup (AC) implant primary stability is an important determinant for the success of cementless hip surgery but it remains difficult to assess the AC implant fixation in the clinic. A method based on the analysis of the impact produced by an instrumented hammer on the ancillary has been developed by our group (Michel et al., 2016a). However, the soft tissue thickness present around the acetabulum may affect the impact response, which may hamper the robustness of the method. The aim of this study is to evaluate the influence of the soft tissue thickness (STT) on the acetabular cup implant primary fixation evaluation using impact analyses. METHODS To do so, different AC implants were inserted in five bovine bone samples. For each sample, different stability conditions were obtained by changing the cavity diameter. For each configuration, the AC implant was impacted 25 times with 10 and 30 mm of soft tissues positioned underneath the sample. The averaged indicator Im was determined based on the amplitude of the signal for each configuration and each STT and the pull-out force was measured. FINDINGS The results show that the resonance frequency of the system increases when the value of the soft tissue thickness decreases. Moreover, an ANOVA analysis shows that there was no significant effect of the value of soft tissue thickness on the values of the indicator Im (F = 2.33; p-value = 0.13). INTERPRETATION This study shows that soft tissue thickness does not appear to alter the prediction of the acetabular cup implant primary fixation obtained using the impact analysis approach, opening the path towards future clinical trials.
Collapse
Affiliation(s)
- Romain Bosc
- NSERM U955, Team 16, Créteil, France; Vaccine Research Institute (VRI), Faculté de Médecine, Créteil, France; Université Paris Est, Créteil, France; Hopital Henri Mondor, Plastic, Reconstructive, Aesthetic and Maxillofacial Surgery Department, 50, avenue du Maréchal de Lattre de Tassigny, 94000 Créteil, France.
| | - Antoine Tijou
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil 94010, France
| | - Giuseppe Rosi
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil 94010, France
| | - Vu-Hieu Nguyen
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil 94010, France
| | - Jean-Paul Meningaud
- Hopital Henri Mondor, Plastic, Reconstructive, Aesthetic and Maxillofacial Surgery Department, 50, avenue du Maréchal de Lattre de Tassigny, 94000 Créteil, France
| | - Philippe Hernigou
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000 Créteil, France
| | - Charles-Henri Flouzat-Lachaniette
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000 Créteil, France; Équipe 10, Groupe 5, IMRB U955, INSERM/UPEC, 51 Avenue du Maréchal de Lattre de Tassigny, 94010 Créteil, France
| | - Guillaume Haiat
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil 94010, France
| |
Collapse
|
20
|
Vayron R, Nguyen VH, Lecuelle B, Haiat G. Evaluation of dental implant stability in bone phantoms: Comparison between a quantitative ultrasound technique and resonance frequency analysis. Clin Implant Dent Relat Res 2018; 20:470-478. [PMID: 29770562 DOI: 10.1111/cid.12622] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 02/22/2018] [Accepted: 04/17/2018] [Indexed: 12/22/2022]
Abstract
BACKGROUND Resonance frequency analyses and quantitative ultrasound methods have been suggested to assess dental implant primary stability. PURPOSE The purpose of this study was to compare the results obtained using these two techniques applied to the same dental implants inserted in various bone phantoms. MATERIALS AND METHODS Different values of trabecular bone density and cortical thickness were considered to assess the effect of bone quality on the respective indicators (UI and ISQ). The effect of the implant insertion depth and of the final drill diameter was also investigated. RESULTS ISQ values increase and UI values decrease as a function of trabecular density, cortical thickness and the screwing of the implant. When the implant diameter varies, the UI values are significantly different for all final drill diameters (except for two), while the ISQ values are similar for all final drill diameters lower than 3.2 mm and higher than 3.3 mm. The error on the estimation of parameters with the QUS device is between 4 and 8 times lower compared to that made with the RFA technique. CONCLUSIONS The results show that ultrasound technique provides a better estimation of different parameters related to the implant stability compared to the RFA technique.
Collapse
Affiliation(s)
- Romain Vayron
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| | - Vu-Hieu Nguyen
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| | - Benoît Lecuelle
- Centre de Recherche BioMédicale, Ecole Nationale Vétérinaire d'Alfort, 7 Avenue du Général de Gaulle, 94700 Maisons-Alfort, France
| | - Guillaume Haiat
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, 61, Avenue du Général de Gaulle, 94010 Créteil, Cedex, France
| |
Collapse
|
21
|
Comparison of Resonance Frequency Analysis and of Quantitative Ultrasound to Assess Dental Implant Osseointegration. SENSORS 2018; 18:s18051397. [PMID: 29724028 PMCID: PMC5982662 DOI: 10.3390/s18051397] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/24/2018] [Revised: 04/09/2018] [Accepted: 04/20/2018] [Indexed: 12/31/2022]
Abstract
Dental implants are widely used in the clinic. However, there remain risks of failure, which depend on the implant stability. The aim of this paper is to compare two methods based on resonance frequency analysis (RFA) and on quantitative ultrasound (QUS) and that aim at assessing implant stability. Eighty-one identical dental implants were inserted in the iliac crests of 11 sheep. The QUS and RFA measurements were realized after different healing times (0, 5, 7, and 15 weeks). The results obtained with the QUS (respectively RFA) method were significantly different when comparing two consecutive healing time for 97% (respectively, 18%) of the implants. The error made on the estimation of the healing time when analyzing the results obtained with the QUS technique was around 10 times lower than that made when using the RFA technique. The results corresponding to the dependence of the ISQ versus healing time were significantly different when comparing two directions of RFA measurement. The results show that the QUS method allows a more accurate determination of the evolution of dental implant stability when compared to the RFA method. This study paves the way towards the development of a medical device, thus providing a decision support system to dental surgeons.
Collapse
|
22
|
Ultrasonic characterization and multiscale analysis for the evaluation of dental implant stability: A sensitivity study. Biomed Signal Process Control 2018. [DOI: 10.1016/j.bspc.2017.12.007] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
23
|
High-Resolution Ultrasonic Imaging of Dento-Periodontal Tissues Using a Multi-Element Phased Array System. Ann Biomed Eng 2016; 44:2874-2886. [DOI: 10.1007/s10439-016-1634-2] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Accepted: 04/29/2016] [Indexed: 10/21/2022]
|
24
|
Vayron R, Nguyen VH, Bosc R, Naili S, Haïat G. Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: A three-dimensional finite element study. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 139:773-780. [PMID: 26936559 DOI: 10.1121/1.4941452] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Dental implant stability is an important determinant of the surgical success. Quantitative ultrasound (QUS) techniques can be used to assess such properties using the implant acting as a waveguide. However, the interaction between an ultrasonic wave and the implant remains poorly understood. The aim of this study is to investigate the sensitivity of the ultrasonic response to the quality and quantity of bone tissue in contact with the implant surface. The 10 MHz ultrasonic response of an implant used in clinical practice was simulated using an axisymmetric three-dimensional finite element model, which was validated experimentally. The amplitude of the echographic response of the implant increases when the depth of a liquid layer located at the implant interface increases. The results show the sensitivity of the QUS technique to the amount of bone in contact with the implant. The quality of bone tissue around the implant is varied by modifying the bone biomechanical properties by 20%. The amplitude of the implant echographic response decreases when bone quality increases, which corresponds to bone healing. In all cases, the amplitude of the implant response decreased when the dental implant stability increased, which is consistent with the experimental results.
Collapse
Affiliation(s)
- Romain Vayron
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Romain Bosc
- Université Paris-Est, INSERM U955, Equipe 10, 8 rue du Général Sarrail, 94010 Créteil Cedex, France
| | - Salah Naili
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR, 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi-Échelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010 Créteil Cedex, France
| |
Collapse
|
25
|
Michel A, Bosc R, Sailhan F, Vayron R, Haiat G. Ex vivo estimation of cementless acetabular cup stability using an impact hammer. Med Eng Phys 2015; 38:80-6. [PMID: 26671784 DOI: 10.1016/j.medengphy.2015.10.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Revised: 08/17/2015] [Accepted: 10/15/2015] [Indexed: 11/29/2022]
Abstract
Obtaining primary stability of acetabular cup (AC) implants is one of the main objectives of press-fit procedures used for cementless hip arthroplasty. The aim of this study is to investigate whether the AC implant primary stability can be evaluated using the signals obtained with an impact hammer. A hammer equipped with a force sensor was used to impact the AC implant in 20 bovine bone samples. For each sample, different stability conditions were obtained by changing the cavity diameter. For each configuration, the inserted AC implant was impacted four times with a maximum force comprised between 2500 and 4500 N. An indicator I was determined based on the partial impulse estimation and the pull-out force was measured. The implant stability and the value of the indicator I reached a maximum value for an interference fit equal to 1 mm for 18 out of 20 samples. When pooling all samples and all configurations, the implant stability and I were significantly correlated (R(2) = 0.83). The AC implant primary stability can be assessed through the analysis of the impact force signals obtained using an impact hammer. Based on these ex vivo results, a medical device could be developed to provide a decision support system to the orthopedic surgeons.
Collapse
Affiliation(s)
- Adrien Michel
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208,61 Avenue du Général de Gaulle, Créteil 94010, France
| | - Romain Bosc
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, Créteil 94000, France
| | - Frédéric Sailhan
- Service de Chirurgie Ostéo-articulaire et carcinologique, Clinique Arago, 54, boulevard Saint-Jacques, 75014 Paris, France
| | - Romain Vayron
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208,61 Avenue du Général de Gaulle, Créteil 94010, France
| | - Guillaume Haiat
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208,61 Avenue du Général de Gaulle, Créteil 94010, France; Ecole de Technologie Superieure, Department of Mechanical Engineering, 1100 Rue Notre-Dame Ouest, Montréal, QC H3C 1K3, Canada.
| |
Collapse
|
26
|
Guipieri S, Nagatani Y, Bosc R, Nguyen VH, Chappard C, Geiger D, Haïat G. Ultrasound Speed of Sound Measurements in Trabecular Bone Using the Echographic Response of a Metallic Pin. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2966-2976. [PMID: 26320667 DOI: 10.1016/j.ultrasmedbio.2015.07.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 06/16/2015] [Accepted: 07/06/2015] [Indexed: 06/04/2023]
Abstract
Bone quality is an important parameter in spine surgery, but its clinical assessment remains difficult. The aim of the work described here was to demonstrate in vitro the feasibility of employing quantitative ultrasound to retrieve bone mechanical properties using an echographic technique taking advantage of the presence of a metallic pin inserted in bone tissue. A metallic pin was inserted in bone tissue perpendicular to the transducer axis. The echographic response of the bone sample was determined, and the echo of the pin inserted in bone tissue and water were compared to determine speed of sound, which was compared with bone volume fraction. A 2-D finite-element model was developed to assess the effect of positioning errors. There was a significant correlation between speed of sound and bone volume fraction (R(2) = 0.6). The numerical results indicate the relative robustness of the measurement method, which could be useful to estimate bone quality intra-operatively.
Collapse
Affiliation(s)
- Séraphin Guipieri
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, Créteil, France
| | - Yoshiki Nagatani
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, Créteil, France; Kobe City College of Technology, Nishiku, Kobe, Japan
| | - Romain Bosc
- Service de Chirurgie Plastique et Reconstructive, Hôpital Henri Mondor AP-HP, F-94000, Créteil, France
| | - Vu-Hieu Nguyen
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, Créteil, France
| | | | - Didier Geiger
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, Créteil, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation MultiEchelle, MSME UMR CNRS 8208, Créteil, France.
| |
Collapse
|
27
|
Finite element simulation of ultrasonic wave propagation in a dental implant for biomechanical stability assessment. Biomech Model Mechanobiol 2015; 14:1021-32. [PMID: 25619479 DOI: 10.1007/s10237-015-0651-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Accepted: 01/10/2015] [Indexed: 12/31/2022]
Abstract
Dental implant stability, which is an important parameter for the surgical outcome, can now be assessed using quantitative ultrasound. However, the acoustical propagation in dental implants remains poorly understood. The objective of this numerical study was to understand the propagation phenomena of ultrasonic waves in cylindrically shaped prototype dental implants and to investigate the sensitivity of the ultrasonic response to the surrounding bone quantity and quality. The 10-MHz ultrasonic response of the implant was calculated using an axisymetric 3D finite element model, which was validated by comparison with results obtained experimentally and using a 2D finite difference numerical model. The results show that the implant ultrasonic response changes significantly when a liquid layer is located at the implant interface compared to the case of an interface fully bounded with bone tissue. A dedicated model based on experimental measurements was developed in order to account for the evolution of the bone biomechanical properties at the implant interface. The effect of a gradient of material properties on the implant ultrasonic response is determined. Based on the reproducibility of the measurement, the results indicate that the device should be sensitive to the effects of a healing duration of less than one week. In all cases, the amplitude of the implant response is shown to decrease when the dental implant primary and secondary stability increase, which is consistent with the experimental results. This study paves the way for the development of a quantitative ultrasound method to evaluate dental implant stability.
Collapse
|
28
|
Ultrasonic evaluation of dental implant osseointegration. J Biomech 2014; 47:3562-8. [PMID: 25262877 DOI: 10.1016/j.jbiomech.2014.07.011] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 07/08/2014] [Accepted: 07/13/2014] [Indexed: 01/22/2023]
Abstract
Dental implants are widely used for oral rehabilitation. However, there remain risks of failure which are difficult to anticipate and depend on the implant osseointegration. The objective of this in vivo study is to determine the variation of the echographic ultrasonic response of a dental implant to bone healing around the implant interface. Twenty one dental implants were inserted in the femur of seven New Zealand white rabbits. Two animals were sacrificed after a healing duration of two weeks, three animals after six weeks and six animals after eleven weeks. The 10 MHz ultrasonic response of the implant was measured just after the implantation using a dedicated device positioned at the emerging surface of each dental implant. The measurements were realized again before the sacrifice with the same device. An indicator I˜ was derived based on the amplitude of the rf signal obtained for each configuration. The bone-Implant Contact (BIC) ratio was determined by histological analyses. The average value of the relative variation of the indicator I˜ obtained after initial surgery and after the corresponding healing period varies between 7% and 40%. A Kruskal-Wallis test (p<0.01) revealed a significant decrease of the value of the indicator I˜ as function of healing time. The indicator I˜ was significantly correlated (R(2)=0.45) with the BIC ratio. The results show that the ultrasonic response of a dental implant varies significantly as a function of healing time, which paves the way for the development of a new quantitative ultrasound (QUS) method in oral implantology.
Collapse
|
29
|
Haïat G, Wang HL, Brunski J. Effects of biomechanical properties of the bone-implant interface on dental implant stability: from in silico approaches to the patient's mouth. Annu Rev Biomed Eng 2014; 16:187-213. [PMID: 24905878 DOI: 10.1146/annurev-bioeng-071813-104854] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Dental implants have become a routinely used technique in dentistry for replacing teeth. However, risks of failure are still experienced and remain difficult to anticipate. Multiscale phenomena occurring around the implant interface determine the implant outcome. The aim of this review is to provide an understanding of the biomechanical behavior of the interface between a dental implant and the region of bone adjacent to it (the bone-implant interface) as a function of the interface's environment. First, we describe the determinants of implant stability in relation to the different multiscale simulation approaches used to model the evolution of the bone-implant interface. Then, we review the various aspects of osseointegration in relation to implant stability. Next, we describe the different approaches used in the literature to measure implant stability in vitro and in vivo. Last, we review various factors affecting the evolution of the bone-implant interface properties.
Collapse
Affiliation(s)
- Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multiéchelle, UMR CNRS 8208, 94010 Créteil, France;
| | | | | |
Collapse
|
30
|
Mathieu V, Vayron R, Richard G, Lambert G, Naili S, Meningaud JP, Haiat G. Biomechanical determinants of the stability of dental implants: influence of the bone-implant interface properties. J Biomech 2013; 47:3-13. [PMID: 24268798 DOI: 10.1016/j.jbiomech.2013.09.021] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2013] [Revised: 09/18/2013] [Accepted: 09/24/2013] [Indexed: 12/19/2022]
Abstract
Dental implants are now widely used for the replacement of missing teeth in fully or partially edentulous patients and for cranial reconstructions. However, risks of failure, which may have dramatic consequences, are still experienced and remain difficult to anticipate. The stability of biomaterials inserted in bone tissue depends on multiscale phenomena of biomechanical (bone-implant interlocking) and of biological (mechanotransduction) natures. The objective of this review is to provide an overview of the biomechanical behavior of the bone-dental implant interface as a function of its environment by considering in silico, ex vivo and in vivo studies including animal models as well as clinical studies. The biomechanical determinants of osseointegration phenomena are related to bone remodeling in the vicinity of the implants (adaptation of the bone structure to accommodate the presence of a biomaterial). Aspects related to the description of the interface and to its space-time multiscale nature will first be reviewed. Then, the various approaches used in the literature to measure implant stability and the bone-implant interface properties in vitro and in vivo will be described. Quantitative ultrasound methods are promising because they are cheap, non invasive and because of their lower spatial resolution around the implant compared to other biomechanical approaches.
Collapse
Affiliation(s)
- Vincent Mathieu
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Romain Vayron
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Gilles Richard
- Septodont, 58 Rue Pont de Créteil, 94100 Saint-Maur-des-Fossés, France
| | - Grégory Lambert
- Septodont, 58 Rue Pont de Créteil, 94100 Saint-Maur-des-Fossés, France
| | - Salah Naili
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Jean-Paul Meningaud
- Service de Chirurgie Plastique, Reconstructrice et Esthétique, CHU H. Mondor, 94017 Créteil cedex, France
| | - Guillaume Haiat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France.
| |
Collapse
|