1
|
Juliebø-Jones P, Æsøy MS, Beisland C, De Coninck V, Keller EX, Tzelves L, Gjengstø P, Arvei Moen C, Somani BK, Ulvik Ø. Adverse events related to laser fibers and laser machines during ureteroscopy and stone lithotripsy: Insights from an updated 10-year analysis of the US MAUDE database. Arch Ital Urol Androl 2024; 96:12374. [PMID: 39356032 DOI: 10.4081/aiua.2024.12374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 02/15/2024] [Indexed: 10/03/2024] Open
Abstract
INTRODUCTION Ureteroscopy has become increasingly chosen as a treatment of choice for patients with kidney stone disease and laser as the energy source for stone lithotripsy is a key part of this. Our aim was to analyse a national database to evaluate the burden of adverse events related to laser fibers and laser machines. METHODS Search was performed of the Manufacturer User and Facility Device Experience (MAUDE) database in the United States for all events related to holmium laser fibers and holmium laser machines during ureteroscopy between 2012-2021. Information collected included the following: problem, timing, prolonged anaesthesia, early termination of procedure, injury and retained parts. RESULTS 699 holmium laser fiber events were reported and these had been manufactured by 13 different companies. The commonest problems were breakage outside the patient while in use (26.3%) and breakage of the laser fiber tip (21.2%). Manufacturers concluded root cause to be device failure in 8.9%. 29% of issues occurred before the laser had been activated. 5.2% of cases had to be cancelled as a result of an event. Significantly more injuries were sustained intra-operatively by operating staff compared to patients (6% vs. 0.2%, p < 0.001). All these injuries were superficial burns to the skin with the hand being the most affected body part (88.1%). Zero ocular injuries were reported. Only eight events were related to laser machines and all involved sudden hardware failure but no patient injury. CONCLUSIONS Laser fibers are fragile. Most adverse events are due to operator error. Direct patient injury from laser fiber is scarce but operating staff should be aware of the risk of sustaining minor burns. Laser machines rarely incur problems and, in this study, did not result in any safety issues beyond need to abort the procedure due to lack of spare equipment.
Collapse
Affiliation(s)
- Patrick Juliebø-Jones
- Department of Urology, Haukeland University Hospital, Bergen; Department of Clinical Medicine, University of Bergen.
| | | | - Christian Beisland
- Department of Urology, Haukeland University Hospital, Bergen; Department of Clinical Medicine, University of Bergen.
| | | | | | - Lazaros Tzelves
- Second Department of Urology, National and Kapodistrian University of Athens, Sismanogleio General Hospital, Athens.
| | - Peder Gjengstø
- Department of Urology, Haukeland University Hospital, Bergen.
| | | | | | - Øyvind Ulvik
- Department of Urology, Haukeland University Hospital, Bergen; Department of Clinical Medicine, University of Bergen.
| |
Collapse
|
2
|
Li X, Feng Y, Gong Y, Chen Y. Assessing the Reproducibility of Research Based on the Food and Drug Administration Manufacturer and User Facility Device Experience Data. J Patient Saf 2024; 20:e45-e58. [PMID: 38470959 PMCID: PMC11636620 DOI: 10.1097/pts.0000000000001220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/14/2024]
Abstract
OBJECTIVE This article aims to assess the reproducibility of Manufacturer and User Facility Device Experience (MAUDE) data-driven studies by analyzing the data queries used in their research processes. METHODS Studies using MAUDE data were sourced from PubMed by searching for "MAUDE" or "Manufacturer and User Facility Device Experience" in titles or abstracts. We manually chose articles with executable queries. The reproducibility of each query was assessed by replicating it in the MAUDE Application Programming Interface. The reproducibility of a query is determined by a reproducibility coefficient that ranges from 0.95 to 1.05. This coefficient is calculated by comparing the number of medical device reports (MDRs) returned by the reproduced queries to the number of reported MDRs in the original studies. We also computed the reproducibility ratio, which is the fraction of reproducible queries in subgroups divided by the query complexity, the device category, and the presence of a data processing flow. RESULTS As of August 8, 2022, we identified 523 articles from which 336 contained queries, and 60 of these were executable. Among these, 14 queries were reproducible. Queries using a single field like product code, product class, or brand name showed higher reproducibility (50%, 33.3%, 31.3%) compared with other fields (8.3%, P = 0.037). Single-category device queries exhibited a higher reproducibility ratio than multicategory ones, but without statistical significance (27.1% versus 8.3%, P = 0.321). Studies including a data processing flow had a higher reproducibility ratio than those without, although this difference was not statistically significant (42.9% versus 17.4%, P = 0.107). CONCLUSIONS Our findings indicate that the reproducibility of queries in MAUDE data-driven studies is limited. Enhancing this requires the development of more effective MAUDE data query strategies and improved application programming interfaces.
Collapse
Affiliation(s)
- Xinyu Li
- Department of Computer Science, Vanderbilt University, Nashville, Tennessee
| | - Yubo Feng
- Department of Computer Science, Vanderbilt University, Nashville, Tennessee
| | - Yang Gong
- School of Biomedical Informatics, The University of Texas Health Science Center at Houston, Houston, Texas
| | - You Chen
- Department of Computer Science, Vanderbilt University, Nashville, Tennessee
- Department of Biomedical Informatics, Vanderbilt University Medical Center, Nashville, Tennessee
| |
Collapse
|
3
|
Johnston SS, Johnson BH, Chakke D, Roy S, Grange P, Pollack E. Retrospective Comparison of Clinical and Economic Outcomes of Non-Donor Patients Undergoing Radical Nephrectomy Using One of Two Different Linear Stapler Technologies for Transection of the Renal Vessels: Fixed-Height Gripping Surface Reloads vs Variable-Height Reloads. MEDICAL DEVICES-EVIDENCE AND RESEARCH 2022; 15:317-328. [PMID: 36092953 PMCID: PMC9450510 DOI: 10.2147/mder.s372629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 08/05/2022] [Indexed: 11/23/2022] Open
Abstract
Purpose To compare outcomes of non-donor patients undergoing radical nephrectomy using fixed-height gripping surface (FHGS) vs variable-height Tri-Staple™ (VHTS) reloads for transection of the renal vessels. Patients and Methods Using the Premier Healthcare Database of US hospital discharge records, we selected non-donor patients undergoing inpatient radical nephrectomy with dates of admission between 1 October 2015, and 31 December 2020 (first=index admission). The primary outcome was in-hospital hemostasis-related complications (hemorrhage, acute posthemorrhagic anemia, and/or procedure to control bleeding) during the index admission. Secondary outcomes included index admission intraoperative injury, blood transfusion, conversion from minimally invasive to open surgery, total hospital costs, length of stay (LOS), discharge status, and mortality as well as 30-day all-cause inpatient readmission. We used stable balancing weights to balance the FHGS and VHTS groups on numerous patient, procedure, and hospital/provider characteristics, allowing a maximum post-weighting standardized mean difference ≤0.01 for all covariates; we also exactly matched the groups on laterality (right vs left kidney) and intended surgical approach (open, laparoscopic, robotic). We used bivariate multilevel mixed-effects generalized linear models accounting for hospital-level clustering to compare the study outcomes between the FHGS and VHTS groups. Results After weighting, the FHGS and VHTS groups comprised 2952 and 795 patients, respectively. The observed incidence proportion of the primary outcome of hemostasis-related complications during the index admission was similar between the groups (8.6% for FHGS vs 9.0% for VHTS, difference 0.4% [95% CI −3.2% to 2.5%], P=0.808). Differences between the FHGS and VHTS groups were not statistically significant for any of the secondary outcomes. Conclusion Endoscopic surgical staplers have become common for transection of the renal vessels during radical nephrectomy, with FHGS and VHTS being the predominant reload types. In this retrospective study of 3747 non-donor patients undergoing radical nephrectomy, use of FHGS vs VHTS reloads was associated with similar clinical and economic outcomes.
Collapse
Affiliation(s)
- Stephen S Johnston
- MedTech Epidemiology and Real-World Data Sciences, Johnson & Johnson, New Brunswick, NJ, USA
- Correspondence: Stephen S Johnston, Real-World Data Analytics and Research, MedTech Epidemiology and Real-World Data Sciences, Johnson & Johnson, 410 George Street, New Brunswick, NJ, USA, Tel +1-443-254-2222, Email
| | - Barbara H Johnson
- MedTech Epidemiology and Real-World Data Sciences, Johnson & Johnson, New Brunswick, NJ, USA
| | | | - Sanjoy Roy
- Franchise Health Economics and Market Access, Johnson & Johnson, Raritan, NJ, USA
| | | | - Esther Pollack
- Franchise Health Economics and Market Access, Johnson & Johnson, Raritan, NJ, USA
| |
Collapse
|
4
|
An DH, Han JH, Jang MJ, Aum J, Kim YS, Jeong IG, Hong B, You D. Solo-surgeon pure laparoscopic donor nephrectomy using passive camera holder: IDEAL stage 2a study. BMC Urol 2022; 22:44. [PMID: 35337318 PMCID: PMC8957188 DOI: 10.1186/s12894-022-00996-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 03/14/2022] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Solo-surgery can be defined as a practice of a surgeon operating alone using a camera holder, without other surgical members except for a scrub nurse. This study was designed to evaluate the feasibility and safety of solo-surgeon pure laparoscopic donor nephrectomy. METHODS The study protocol was approved by the Institutional Review Board of Asan Medical Center, Seoul, Korea. The brief study protocol was registered on the Clinical Research Information Service site of the Korea Centers for Disease Control and Prevention. Candidates fulfilling all inclusion and exclusion criteria were enrolled in the clinical trial and underwent solo-surgeon pure laparoscopic donor nephrectomy. The feasibility was assessed by the proportion of subjects who could undergo solo-surgeon pure laparoscopic donor nephrectomy without difficulty. The perioperative complications were identified to assess the safety of solo-surgeon pure laparoscopic donor nephrectomy. RESULTS Of the 47 potential candidates from November 2018 to August 2019, 40 were enrolled in the clinical trial and seven excluded due to declining participation. The feasibility of solo-surgeon pure laparoscopic donor nephrectomy was 100%, without an occasion of any difficulty requiring conversion to the human assisted pure laparoscopic donor nephrectomy. Fourteen intraoperative complications occurred in 10 patients. The most common intraoperative complication was spleen injury. Two of three cases classified as the Satava classification grade II were due to the incomplete stapling of endoscopic stapler. Seventy-eight postoperative complications occurred in 34 patients. The most common postoperative complication was nausea/vomiting and followed by aspartate aminotransferase/alanine aminotransferase elevation. Most postoperative complication was independent of the solo-surgery itself. CONCLUSIONS Solo-surgeon pure laparoscopic donor nephrectomy using passive camera holder is technically feasible. In terms of safety, it is necessary to adjust the scope of surgery performed alone. Trial Registration CRIS, KCT0003458. Registered 30/01/2019, Retrospectively registered, https://cris.nih.go.kr/cris/search/detailSearch.do/15868 .
Collapse
Affiliation(s)
- Dong Hyeon An
- Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jae Hyeon Han
- Department of Urology, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, Korea
| | - Myoung Jin Jang
- Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea
| | - Joomin Aum
- Department of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Korea
| | - Yu Seon Kim
- Department of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Korea
| | - In Gab Jeong
- Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Bumsik Hong
- Department of Urology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Dalsan You
- Department of Urology, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Korea.
| |
Collapse
|
5
|
Clapp B, Schrodt A, Ahmad M, Wicker E, Sharma N, Vivar A, Davis B. Stapler Malfunctions in Bariatric Surgery: An Analysis of the MAUDE Database. JSLS 2022; 26:JSLS.2021.00074. [PMID: 35281706 PMCID: PMC8896815 DOI: 10.4293/jsls.2021.00074] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Background Staple line leaks are a serious problem in bariatric surgery and a major cause of serious morbidity and mortality. Adverse events caused by medical devices are reported to the Food and Drug Administration which maintains the Manufacturer and User Facility Device Experience (MAUDE) database. We examined adverse stapler events reported to the MAUDE database, specifically with regards to bariatric surgery. Methods The MAUDE database was queried for adverse events caused by staplers between January 1, 2018 - December 31, 2020; events reported by Intuitive, Ethicon, and Medtronic/Covidien; and limited our search to "gastric bypass", "sleeve gastrectomy", "stapler malfunction" combined with each company. Results There were 883 adverse events reported for Medtronic, 353 for Ethicon, and 35 for Intuitive. Approximately 3.5 million staple reloads sold in the study period. The reported misfire rate for Medtronic was 0.04% and for Ethicon was 0.02%. Data for Intuitive was unavailable. The most common reported event for Medtronic was failure to fire (n = 349), followed by misfire (n = 186). For Ethicon, the most common event was failure to fire (n = 146), followed by mechanical problems (n = 27). The most common event with the Intuitive stapler was leak (n = 10) and bleeding from staple line (n = 8). Conclusions Stapler malfunction is a very rare event in metabolic and bariatric surgery. All of the major stapler producers have transitioned to powered staplers with excellent safety profiles. Open and honest reporting about stapler malfunction is essential to determine the true safety of these ubiquitous devices.
Collapse
Affiliation(s)
- Benjamin Clapp
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Alexander Schrodt
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Maria Ahmad
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Ellen Wicker
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Nishtha Sharma
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| | - Andres Vivar
- Universidad Autonoma Guadalajara, Guadalajara, Mexico
| | - Brian Davis
- Department of Surgery, Texas Tech HSC Paul Foster School of Medicine, El Paso, TX, USA
| |
Collapse
|