1
|
Lahoud C, Kreidieh M, Abureesh M, El Douaihy Y. A Unique Case of a Successful Endoscopic Retrograde Cholangiopancreatography Through a Previously Placed Gastro-Jejunostomy Lumen Apposing Metal Stent. ACG Case Rep J 2025; 12:e01703. [PMID: 40357369 PMCID: PMC12068777 DOI: 10.14309/crj.0000000000001703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2025] [Accepted: 04/08/2025] [Indexed: 05/15/2025] Open
Abstract
Originally used for minimally invasive drainage of pancreatic fluid collections, the uses of lumen-apposing metal stents (LAMS) have expanded to encompass several other pathologies including gastric outlet obstruction, strictures, and cases with surgically altered anatomy. We describe a rare case of an endoscopic retrograde cholangiopancreatography that was successfully completed through a previously placed LAMS between the stomach and the jejunum, in a patient with challenging anatomy due to progressing malignancy resulting in gastric outlet obstruction. This case highlights the technical complexity of performing endoscopic retrograde cholangiopancreatography through a previously placed LAMS and underscores the importance of patient-centered care with readiness for adaptability in complex cases.
Collapse
Affiliation(s)
- Chloe Lahoud
- Department of Internal Medicine, Staten Island University Hospital, Staten Island, NY
| | - Malek Kreidieh
- Department of Internal Medicine, Division of Gastroenterology and Hepatology, Staten Island University Hospital, Staten Island, NY
| | - Mohammad Abureesh
- Department of Internal Medicine, Division of Gastroenterology and Hepatology, Staten Island University Hospital, Staten Island, NY
| | - Youssef El Douaihy
- Department of Internal Medicine, Division of Gastroenterology and Hepatology, Staten Island University Hospital, Staten Island, NY
| |
Collapse
|
2
|
Tyberg A, Binmoeller K, Kowalski T. Lumen-apposing metal stents in 2024: troubleshooting and managing common and uncommon adverse events. Gastrointest Endosc 2025; 101:315-330. [PMID: 39369965 DOI: 10.1016/j.gie.2024.09.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Revised: 08/21/2024] [Accepted: 09/25/2024] [Indexed: 10/08/2024]
Affiliation(s)
- Amy Tyberg
- Hackensack Meridian Health, Hackensack University Hospital, New York, New York, USA
| | | | - Thomas Kowalski
- Pancreaticobiliary & Advanced Endoscopy Section, Sidney Kimmel College of Medicine, Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
3
|
Brown NG, Sethi A. Endoscopic Drainage of Pancreatic Fluid Collections. Gastrointest Endosc Clin N Am 2024; 34:553-575. [PMID: 38796299 DOI: 10.1016/j.giec.2024.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2024]
Abstract
Pancreatic fluid collections (PFCs) are commonly encountered complications of acute and chronic pancreatitis. With the advancement of endoscopic ultrasound (EUS) techniques and devices, EUS-directed transmural drainage of symptomatic or infected PFCs has become the standard of care. Traditionally, plastic stents have been used for drainage, although lumen-apposing metal stents (LAMSs) are now favored by most endoscopists due to ease of use and reduced procedure time. While safety has been repeatedly demonstrated, follow-up care for these patients is critical as delayed adverse events of indwelling drains are known to occur.
Collapse
Affiliation(s)
- Nicholas G Brown
- Department of Medicine, Columbia University Irving Medical Center, Weill Cornell Medicine, NewYork-Presbyterian/Brooklyn Methodist Hospital, 515 6th Street, Concourse, Brooklyn, NY 11215, USA; Weill Cornell, 1283 York Avenue, New York, NY 10065, USA; Division of Digestive and Liver Disease, Columbia University Irving Medical Center, 630 West 168th Street, P&S 3-401, New York, NY 10032, USA.
| | - Amrita Sethi
- Division of Digestive and Liver Disease, Columbia University Irving Medical Center, 630 West 168th Street, P&S 3-401, New York, NY 10032, USA
| |
Collapse
|
4
|
Nimri F, Ichkhanian Y, Shinn B, Kowalski TE, Loren DE, Kumar A, Schlachterman A, Tantau A, Arevalo M, Taha A, Shamaa O, Viales MC, Khashab MA, Simmer S, Singla S, Piraka C, Zuchelli TE. Comprehensive analysis of adverse events associated with transmural use of LAMS in patients with liver cirrhosis: International multicenter study. Endosc Int Open 2024; 12:E740-E749. [PMID: 38847015 PMCID: PMC11156515 DOI: 10.1055/a-2312-1528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2023] [Accepted: 04/16/2024] [Indexed: 06/09/2024] Open
Abstract
Background and study aims Endoscopic ultrasound (EUS)-guided transmural (TM) deployment of lumen-apposing metal stents (LAMS) is considered relatively safe in non-cirrhotic patients and is cautiously offered to cirrhotic patients. Patients and methods This was a retrospective, multicenter, international matched case-control study to study the safety of EUS-guided TM deployment of LAMS in cirrhotic patients. Results Forty-three cirrhotic patients with model for end-stage liver disease score 12.5 ± 5, with 23 having ascites and 16 with varices underwent EUS-guided TM LAMS deployment, including 19 for pancreatic fluid collection (PFC) drainage, 13 gallbladder drainage, six for endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (ERCP), three for EDGI, one for endoscopic ultrasound-directed transenteric ERCP, and one postsurgical collection drainage. Technical failure occurred in one LAMS for PFC drainage. Clinical failure was encountered in another PFC. Nine adverse events (AEs) occurred. The most common AE was LAMS migration (3), followed by non-bleeding mucosal erosion (2), delayed bleeding (2), sepsis (1), and anesthesia-related complication (pulseless electrical activity) (1). Most AEs were graded as mild (6), followed by severe (2), and moderate (1); the majority were managed conservatively. On univariable comparison, risk of AE was higher when using a 20 × 10 mm LAMS and the absence of through-the-LAMS plastic stent(s). Conditional logistic regression of matched case-control patients did not show any association between potential predicting factors and occurrence of AEs. Conclusions Our study demonstrated that mainly in patients with Child-Pugh scores A and B cirrhosis and despite the presence of mild-to-moderate ascites in over half of cases, the majority of AEs were mild and could be managed conservatively. Further studies are warranted to verify the safety of LAMS in cirrhotic patients.
Collapse
Affiliation(s)
- Faisal Nimri
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Yervant Ichkhanian
- Department of Internal Medicine, Henry Ford Hospital, Detroit, United States
| | - Brianna Shinn
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Thomas E. Kowalski
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - David E. Loren
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Anand Kumar
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Alexander Schlachterman
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Wayne, United States
| | - Alina Tantau
- Division of Gastroenterology and Hepatology Medical Center, Iuliu Hatieganu University of Medicine and Pharmacy, Cluj-Napoca, Romania
| | - Martha Arevalo
- Instituto Ecuatoriano de Enfermedades Digestivas (IECED), Guayaquil, Ecuador
| | - Ashraf Taha
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Omar Shamaa
- Department of Internal Medicine, Henry Ford Hospital, Detroit, United States
| | | | - Mouen A. Khashab
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, United States
| | - Stephen Simmer
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Sumit Singla
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Cyrus Piraka
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| | - Tobias E. Zuchelli
- Division of Gastroenterology and Hepatology, Henry Ford Hospital, Detroit, United States
| |
Collapse
|
5
|
Troncone E, Perez‐Miranda M. EUS‐guided enteric anastomoses. ENDOSCOPIC ULTRASONOGRAPHY 2024:251-260. [DOI: 10.1002/9781119697893.ch27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/02/2025]
|
6
|
Cui Y, Almario JA, Bejjani M, Khashab MA, Irani S. Primary anastomosis closure after endoscopic ultrasound-directed transgastric intervention. Endosc Int Open 2024; 12:E526-E531. [PMID: 38628391 PMCID: PMC11018386 DOI: 10.1055/a-2272-0927] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 02/14/2024] [Indexed: 04/19/2024] Open
Abstract
Background and study aims Endoscopic ultrasound-directed transgastric intervention (EDGI) is a technique that creates an anastomosis between the gastric pouch or jejunum to the excluded stomach in Roux-en-Y gastric bypass (RYGB) anatomy to allow access to the pancreaticobiliary system. Thus far, management of anastomosis closure at the time of lumen-apposing metal stent (LAMS) removal has varied widely. This study aimed to assess the efficacy of primary closure at the time of LAMS removal using a through-the-scope (TTS) tack-based suture system. Patients and methods This was a two-center retrospective study of RYGB patients who underwent single-stage EDGI using a 20-mm LAMS and subsequent primary anastomosis closure with the X-tack system at the time of stent removal. Patient demographics, procedure details, clinical outcomes, and imaging findings are reported. Results Nineteen patients (median age 63 years, 84% female) underwent single-stage EDGI with a median follow-up of 31.5 months. Adverse events occurred in two patients (11%) who had abdominal pain requiring hospitalization. The median LAMS dwell time was 32 days (range 16-86). All patients (100%) who underwent follow-up studies after LAMS removal had confirmed anastomosis closure (n = 18). Most patients had documented weight loss at the time of LAMS removal and at last follow-up (68%, n = 13). Conclusions Single-stage EDGI is an effective approach to managing RYGB patients with pancreaticobiliary pathology. Thus far, endoscopic TTS tack-based suturing appears to have a high success rate in anastomosis closure after LAMS removal and should be considered as a primary method for preventing chronic fistulae.
Collapse
Affiliation(s)
- YongYan Cui
- Gastroenterology, Virginia Mason Medical Center, Seattle, United States
| | | | - Michael Bejjani
- Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, United States
| | - Mouen A. Khashab
- Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, United States
| | - Shayan Irani
- Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, United States
| |
Collapse
|
7
|
Stefanovic S, Adler DG, Arlt A, Baron TH, Binmoeller KF, Bronswijk M, Bruno MJ, Chevaux JB, Crinò SF, Degroote H, Deprez PH, Draganov PV, Eisendrath P, Giovannini M, Perez-Miranda M, Siddiqui AA, Voermans RP, Yang D, Hindryckx P. International Consensus Recommendations for Safe Use of LAMS for On- and Off-Label Indications Using a Modified Delphi Process. Am J Gastroenterol 2024; 119:671-681. [PMID: 37934190 DOI: 10.14309/ajg.0000000000002571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 10/02/2023] [Indexed: 11/08/2023]
Abstract
INTRODUCTION The study aimed to develop international consensus recommendations on the safe use of lumen-apposing metal stents (LAMSs) for on- and off-label indications. METHODS Based on the available literature, statements were formulated and grouped into the following categories: general safety measures, peripancreatic fluid collections, endoscopic ultrasound (EUS)-biliary drainage, EUS-gallbladder drainage, EUS-gastroenterostomy, and gastric access temporary for endoscopy. The evidence level of each statement was determined using the Grading of Recommendations Assessment, Development, and Evaluation methodology.International LAMS experts were invited to participate in a modified Delphi process. When no 80% consensus was reached, the statement was modified based on expert feedback. Statements were rejected if no consensus was reached after the third Delphi round. RESULTS Fifty-six (93.3%) of 60 formulated statements were accepted, of which 35 (58.3%) in the first round. Consensus was reached on the optimal learning path, preprocedural imaging, the need for airway protection and essential safety measures during the procedure, such as the use of Doppler, and measurement of the distance between the gastrointestinal lumen and the target structure. Specific consensus recommendations were generated for the different LAMS indications, covering, among others, careful patient selection, the preferred size of the LAMS, the need for antibiotics, the preferred anatomic location of the LAMS, the need for coaxial pigtail placement, and the appropriate management of LAMS-related adverse events. DISCUSSION Through a modified international Delphi process, we developed general and indication-specific experience- and evidence-based recommendations on the safe use of LAMS.
Collapse
Affiliation(s)
- Sebastian Stefanovic
- Department of Gastroenterology, Ghent University Hospital, Ghent, Belgium
- Diagnostic Center Bled Group, Bled, Slovenia
| | - Douglas G Adler
- Centura Health, Center for Advanced Therapeutic Endoscopy, Colorado, Englewood, USA
| | - Alexander Arlt
- Department of Internal Medicine and Gastroenterology, Carl von Ossietzky University Oldenburg, Oldenburg, Germany
| | - Todd H Baron
- Division of Gastroenterology and Hepatology, University of North Carolina, Chapel Hill, North Carolina, USA
| | - Kenneth F Binmoeller
- Interventional Endoscopy Services, California Pacific Medical Center, San Francisco, California, USA
| | - Michiel Bronswijk
- Gastroenterology and Hepatology, Imelda Hospital Bonheiden and University Hospitals Leuven, Belgium
| | - Marco J Bruno
- Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center, Rotterdam, Netherlands
| | | | - Stefano Francesco Crinò
- Department of Medicine, Gastroenterology and Digestive Endoscopy Unit, The Pancreas Institute, University Hospital of Verona, Verona, Italy
| | - Helena Degroote
- Department of Gastroenterology, Ghent University Hospital, Ghent, Belgium
| | - Pierre H Deprez
- Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, Department of Hepatogastroenterology, Brussels, Belgium
| | | | - Pierre Eisendrath
- Department of Gastroenterology, Hepatopancreatology and Digestive Oncology, Saint-Pierre University Hospital, Université Libre de Bruxelles, Brussels, Belgium
| | - Marc Giovannini
- Digestive Endoscopy Unit, Paoli Calmettes Institute, Marseille Cedex 9, France
| | - Manuel Perez-Miranda
- Gastroenterology Department, Hospital Universitario Río Hortega, Valladolid, Spain
| | - Ali A Siddiqui
- Department of Gastroenterology and Hepatology, Inova Fairfax Hospital, Falls Church, Virginia, USA
| | - Rogier P Voermans
- Amsterdam University Medical Center, Department of Gastroenterology and Hepatology, University of Amsterdam, Amsterdam, Netherlands
| | - Dennis Yang
- Center for Interventional Endoscopy, AdventHealth, Orlando, Florida, USA
| | - Pieter Hindryckx
- Department of Gastroenterology, Ghent University Hospital, Ghent, Belgium
| |
Collapse
|
8
|
Deliwala SS, Mohan BP, Yarra P, Khan SR, Chandan S, Ramai D, Kassab LL, Facciorusso A, Dhawan M, Adler DG, Kaul V, Chawla S, Kochhar GS. Efficacy & safety of EUS-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) in Roux-en-Y gastric bypass anatomy: a systematic review & meta-analysis. Surg Endosc 2023; 37:4144-4158. [PMID: 36792784 DOI: 10.1007/s00464-023-09926-7] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Accepted: 01/28/2023] [Indexed: 02/17/2023]
Abstract
BACKGROUND In patients with Roux-en-Y gastric bypass (RYGB) anatomy, laparoscopic endoscopic retrograde cholangiopancreatography (LA-ERCP) and enteroscopy-assisted ERCP (E-ERCP) have been utilized to achieve pancreaticobiliary access. Endoscopic ultrasound-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) has recently emerged as an alternate and efficient approach. As data regarding EDGE continues to evolve, concerns about safety and efficacy remain, limiting wide adoptability. We performed a systematic review and meta-analysis to assess the safety and efficacy of EDGE and compare it to the current standard of care. METHODS A comprehensive search of major databases (inception to Nov 2022) identified published studies on EDGE. A random-effects model was used to calculate the pooled rates and heterogeneity (I2). Risk ratio (RR) and standardized difference in means (SMD) were utilized for head-to-head comparison analysis between EDGE vs. LA-ERCP and EDGE vs. E-ERCP. Primary outcomes assessed pooled EDGE safety (adverse events) and efficacy (technical/clinical success). Secondary outcomes assessed efficacy and safety profiles via a comparative analysis of EDGE vs. LA-ERCP and EDGE vs. E-ERCP. RESULTS A total of 16 studies (470 patients) were included. EDGE pooled technical success (TS) rate was 96% (95% CI 92-97.6, I2 = 0), and clinical success was 91% (85-95, I2 = 0). Pooled rate of all adverse events with EDGE was 17% (14-24.6, I2 = 32%). On sub-group analysis, these included failure of fistula closure 17% (10-25.5, I2 = 48%), stent migration 7% (4-12, I2 = 51%), bleeding 5% (3.2-7.9, I2 = 0), post-EDGE weight gain 4% (2-9, I2 = 0), perforation 4% (2.1-5.8, I2 = 0), and post-ERCP pancreatitis 2% (1-5, I2 = 0). EDGE TS was comparable to LA-ERCP (97% vs. 98%; RR, 1.00; CI, 0.85-1.17, p = 0.95) and E-ERCP (100% vs. 66%; RR, 1.26; CI, 0.99-1.6, p = 0.06). No statistical difference was noted in adverse events between EDGE and LA-ERCP (13% vs. 17.6%; RR, 0.61; CI, 0.28-1.35, p = 0.52) and E-ERCP (9.6% vs. 16%; RR, 0.61; CI, 0.28-1.35, p = 0.22). EDGE procedure time and hospital stay were shorter than LA-ERCP and E-ERCP (p < 0.001). CONCLUSION Our analysis shows that EDGE is safe and efficacious to the current standard of care. Further head-to-head comparative trials are needed to validate our findings.
Collapse
Affiliation(s)
- Smit S Deliwala
- Division of Digestive Diseases, Emory University School of Medicine, Atlanta, GA, USA.
| | - Babu P Mohan
- Gastroenterology & Hepatology, University of Utah Health School of Medicine, Salt Lake City, UT, USA
| | - Pradeep Yarra
- Internal Medicine, University of Kentucky, Lexington, KY, USA
| | | | - Saurabh Chandan
- Division of Gastroenterology & Hepatology, CHI Creighton University Medical Center, Omaha, NE, USA
| | - Daryl Ramai
- Gastroenterology & Hepatology, University of Utah Health School of Medicine, Salt Lake City, UT, USA
| | | | - Antonio Facciorusso
- Department of Medical and Surgical Sciences, Gastroenterology Unit, University of Foggia, Foggia, Italy
| | - Manish Dhawan
- Division of Gastroenterology, Hepatology & Nutrition, Allegheny Health Network, Pittsburgh, PA, USA
| | - Douglas G Adler
- Center for Advanced Therapeutic Endoscopy, Centura Health, Denver, CO, USA
| | - Vivek Kaul
- Division of Gastroenterology & Hepatology, University of Rochester Medical Center, Rochester, NY, USA
| | - Saurabh Chawla
- Division of Digestive Diseases, Emory University School of Medicine, Atlanta, GA, USA
| | - Gursimran S Kochhar
- Division of Gastroenterology, Hepatology & Nutrition, Allegheny Health Network, Pittsburgh, PA, USA
| |
Collapse
|
9
|
Itonaga M, Kitano M, Ashida R. Development of devices for interventional endoscopic ultrasound for the management of pancreatobiliary diseases. Dig Endosc 2023; 35:302-313. [PMID: 36052861 DOI: 10.1111/den.14428] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Accepted: 08/30/2022] [Indexed: 02/08/2023]
Abstract
A variety of devices have been developed for interventional endoscopic ultrasound (EUS). EUS-guided drainage of the bile duct and pancreatic duct, as well as fluid collection adjacent to the gastrointestinal tract, is performed by a procedure involving puncture, guidewire manipulation, tract dilation, and stent placement. Devices specialized for interventional EUS are being developed for each step of the procedure. Mechanical dilators such as bougie, balloon, and electrocautery dilators are used for tract dilation. Various types of plastic stents, self-expandable metal stents, and lumen-apposing metal stents specifically designed for interventional EUS are now available, including one-step devices developed to improve the efficacy and safety of interventional EUS. In addition, radiofrequency ablation and the placement of fiducial markers and radioactive seeds under EUS guidance are now becoming established for pancreatic neoplasms. Such development of specialized devices has expanded the indications for interventional EUS, increased the success rate, and lowered the adverse event rate.
Collapse
Affiliation(s)
- Masahiro Itonaga
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Masayuki Kitano
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| | - Reiko Ashida
- Second Department of Internal Medicine, Wakayama Medical University, Wakayama, Japan
| |
Collapse
|
10
|
Helix tack for lumen-apposing metal stent fixation in single-session EUS-directed transgastric ERCP. VideoGIE 2023; 8:151-154. [PMID: 37095842 PMCID: PMC10122067 DOI: 10.1016/j.vgie.2022.11.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/11/2023] Open
Abstract
Video 1Helix tack for lumen-apposing metal stent fixation in single-session EUS-directed transgastric ERCP.
Collapse
|
11
|
Ghandour B, Keane MG, Shinn B, Dawod QM, Fansa S, El Chafic AH, Irani SS, Pawa R, Gutta A, Ichkhanian Y, Paranandi B, Pawa S, Al-Haddad MA, Zuchelli T, Huggett MT, Sharaiha RZ, Kowalski TE, Khashab MA, Shrigiriwar A, Zhang L, Mony S, Khan A, Loren DE, Chiang A, Schlachterman A, Kumar A, Saab O, Blake B, Obri MS. Factors predictive of persistent fistulas in EUS-directed transgastric ERCP: a multicenter matched case-control study. Gastrointest Endosc 2023; 97:260-267. [PMID: 36228699 DOI: 10.1016/j.gie.2022.09.028] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 09/16/2022] [Accepted: 09/26/2022] [Indexed: 01/25/2023]
Abstract
BACKGROUND AND AIMS EUS-directed transgastric ERCP (EDGE) is an established method for managing pancreaticobiliary pathology in Roux-en-Y gastric bypass patients, with high rates of technical success and low rates of serious adverse events (AEs). However, widespread adoption of the technique has been limited because of concerns about the development of persistent gastrogastric or jejunogastric fistulas. Gastrogastric and jejunogastric fistulas have been reported in up to 20% of cases in some series, but predictive risk factors and long-term management and outcomes are lacking. Therefore, our aims were to assess factors associated with the development of persistent fistulas and the technical success of endoscopic fistula closure. METHODS This is a case-control study involving 9 centers (8 USA, 1 Europe) from February 2015 to September 2021. Cases of persistent fistulas were defined as endoscopic or imaging evidence of fistula more than 8 weeks after lumen-apposing metal stent (LAMS) removal. Control subjects were defined as endoscopic or imaging confirmation of no fistula more than 8 weeks after LAMS removal. AEs were defined and graded according to the American Society for Gastrointestinal Endoscopy lexicon. RESULTS Twenty-five patients identified to have evidence of a persistent fistula on follow-up surveillance (cases) were matched with 50 patients with no evidence of a persistent fistula on follow-up surveillance (control subjects) based on age and sex. Mean LAMS dwell time was 74.7 ± 106.2 days. After LAMS removal, argon plasma coagulation (APC) ablation of the fistula was performed in 46 patients (61.3%). Primary closure of the fistula was performed in 26.7% of patients (20: endoscopic suturing in 17, endoscopic tacking in 2, and over-the-scope clips + endoscopic suturing in 1). When comparing cases with control subjects, there was no difference in baseline demographics, fistula site, LAMS size, or primary closure frequency between the 2 groups (P > .05). However, in the persistent fistula group, the mean LAMS dwell time was significantly longer (127 vs 48 days, P = .02) and more patients had ≥5% total body weight gain (33.3% vs 10.3%, P = .03). LAMS dwell time was a significant predictor of persistent fistula (odds ratio, 4.5 after >40 days in situ, P = .01). The odds of developing a persistent fistula increased by 9.5% for every 7 days the LAMS was left in situ. In patients with a persistent fistula, endoscopic closure was attempted in 19 (76%) with successful resolution in 14 (73.7%). CONCLUSIONS Longer LAMS dwell time was found to be associated with a higher risk of persistent fistulas in EDGE patients. APC or primary closure of the fistula on LAMS removal was not found to be protective against developing a persistent fistula, which, if present, can be effectively managed through endoscopic closure in most cases.
Collapse
Affiliation(s)
- Bachir Ghandour
- Division of Gastroenterology and Hepatology, Johns Hopkins Medicine, Baltimore, Maryland, USA
| | - Margaret G Keane
- Division of Gastroenterology and Hepatology, Johns Hopkins Medicine, Baltimore, Maryland, USA
| | - Brianna Shinn
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Philadelphia, Pennsylvania, USA
| | - Qais M Dawod
- Division of Gastroenterology and Hepatology, Weill Cornell Medicine, New York, New York, USA
| | - Sima Fansa
- Department of Internal Medicine, American University of Beirut Medical Center, Beirut, Lebanon
| | - Abdul Hamid El Chafic
- Division of Gastroenterology and Hepatology, Ochsner Medical Center-New Orleans, New Orleans, Louisiana, USA
| | - Shayan S Irani
- Division of Gastroenterology and Hepatology, Virginia Mason Medical Center, Seattle, Washington, USA
| | - Rishi Pawa
- Division of Gastroenterology and Hepatology, Wake Forest Baptist Health, Winston-Salem, North Carolina, USA
| | - Aditya Gutta
- Division of Gastroenterology and Hepatology, Indiana University Medical Center, Indianapolis, Indiana, USA
| | - Yervant Ichkhanian
- Division of Gastroenterology and Hepatology, Henry Ford Health System, Detroit, Michigan, USA
| | - Bharat Paranandi
- Division of Gastroenterology and Hepatology, Leeds Teaching Hospitals NHS Trust, Leeds, Leeds, UK
| | - Swati Pawa
- Division of Gastroenterology and Hepatology, Wake Forest Baptist Health, Winston-Salem, North Carolina, USA
| | - Mohammad A Al-Haddad
- Division of Gastroenterology and Hepatology, Indiana University Medical Center, Indianapolis, Indiana, USA
| | - Tobias Zuchelli
- Division of Gastroenterology and Hepatology, Henry Ford Health System, Detroit, Michigan, USA
| | - Matthew T Huggett
- Division of Gastroenterology and Hepatology, Leeds Teaching Hospitals NHS Trust, Leeds, Leeds, UK
| | - Reem Z Sharaiha
- Division of Gastroenterology and Hepatology, Weill Cornell Medicine, New York, New York, USA
| | - Thomas E Kowalski
- Division of Gastroenterology and Hepatology, Thomas Jefferson Hospital, Philadelphia, Pennsylvania, USA
| | - Mouen A Khashab
- Division of Gastroenterology and Hepatology, Johns Hopkins Medicine, Baltimore, Maryland, USA
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Elfert K, Zeid E, Duarte-Chavez R, Kahaleh M. Endoscopic ultrasound guided access procedures following surgery. Best Pract Res Clin Gastroenterol 2022; 60-61:101812. [PMID: 36577531 DOI: 10.1016/j.bpg.2022.101812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 11/13/2022] [Indexed: 11/17/2022]
Abstract
EUS-guided therapeutic procedures have emerged in the recent years as a minimally invasive option for the management of complex hepatobiliary disorders. Gastrointestinal surgeries, e.g., pancreaticoduodenectomy, Roux-en-Y Gastric Bypass, Roux-en-Y hepaticojejunostomy, and partial gastrectomy with different reconstructions are commonly performed for a wide range of indications that include tumour resections and weight loss. Conventional endoscopic procedures are challenging in those patients due to inaccessible or unreachable ampulla. Patients with surgically altered anatomy are good candidates for EUS-guided access procedures that have shown good technical and clinical success rates. This category of procedures includes EUS-guided biliary drainage, EUS-guided pancreatic drainage, EUS-directed transgastric ERCP (EDGE) and EUS-guided Gastroenterostomy. Studies have shown that these procedures have comparable or better results than traditional endoscopic, interventional radiology-guided and surgical procedures. This article discusses the indications, technique and outcome of the different EUS-guided access procedures in patients with surgically altered anatomy.
Collapse
Affiliation(s)
- Khaled Elfert
- Department of Medicine, SBH Health System, Bronx, NY, USA.
| | - Ebrahim Zeid
- Department of Surgery, Kafr El Zayat General Hospital, Kafr EL Zayat, Gharbiyah, Egypt.
| | - Rodrigo Duarte-Chavez
- Gastroenterology Division, Department of Medicine, St Luke's University Health Network, Bethlehem, PA, USA.
| | - Michel Kahaleh
- Gastroenterology Division, Department of Medicine, Robert Wood Johnson University Hospital, New Brunswick, NJ, USA.
| |
Collapse
|
13
|
van Wanrooij RLJ, Bronswijk M, Kunda R, Everett SM, Lakhtakia S, Rimbas M, Hucl T, Badaoui A, Law R, Arcidiacono PG, Larghi A, Giovannini M, Khashab MA, Binmoeller KF, Barthet M, Pérez-Miranda M, van Hooft JE, van der Merwe SW. Therapeutic endoscopic ultrasound: European Society of Gastrointestinal Endoscopy (ESGE) Technical Review. Endoscopy 2022; 54:310-332. [PMID: 35114696 DOI: 10.1055/a-1738-6780] [Citation(s) in RCA: 102] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
1: ESGE recommends a prolonged course of a prophylactic broad-spectrum antibiotic in patients with ascites who are undergoing therapeutic endoscopic ultrasound (EUS) procedures.Strong recommendation, low quality evidence. 2: ESGE recommends placement of partially or fully covered self-expandable metal stents during EUS-guided hepaticogastrostomy for biliary drainage in malignant disease.Strong recommendation, moderate quality evidence. 3: ESGE recommends EUS-guided pancreatic duct (PD) drainage should only be performed in high volume expert centers, owing to the complexity of this technique and the high risk of adverse events.Strong recommendation, low quality evidence. 4: ESGE recommends a stepwise approach to EUS-guided PD drainage in patients with favorable anatomy, starting with rendezvous-assisted endoscopic retrograde pancreatography (RV-ERP), followed by antegrade or transmural drainage only when RV-ERP fails or is not feasible.Strong recommendation, low quality evidence. 5: ESGE suggests performing transduodenal EUS-guided gallbladder drainage with a lumen-apposing metal stent (LAMS), rather than using the transgastric route, as this may reduce the risk of stent dysfunction.Weak recommendation, low quality evidence. 6: ESGE recommends using saline instillation for small-bowel distension during EUS-guided gastroenterostomy.Strong recommendation, low quality evidence. 7: ESGE recommends the use of saline instillation with a 19G needle and an electrocautery-enhanced LAMS for EUS-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) procedures.Strong recommendation, low quality evidence. 8: ESGE recommends the use of either 15- or 20-mm LAMSs for EDGE, with a preference for 20-mm LAMSs when considering a same-session ERCP.Strong recommendation, low quality evidence.
Collapse
Affiliation(s)
- Roy L J van Wanrooij
- Department of Gastroenterology and Hepatology, Amsterdam UMC, Vrije Universiteit Amsterdam, AGEM Institute, Amsterdam, The Netherlands
| | - Michiel Bronswijk
- Department of Gastroenterology and Hepatology, Imelda General Hospital, Bonheiden, Belgium
- Department of Gastroenterology and Hepatology, University Hospitals Leuven, Leuven, Belgium
| | - Rastislav Kunda
- Department of Surgery, Department of Gastroenterology and Hepatology, and Department of Advanced Interventional Endoscopy, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Simon M Everett
- Department of Gastroenterology and Hepatology, Leeds Teaching Hospital NHS Trust, Leeds, UK
| | - Sundeep Lakhtakia
- Department of Medical Gastroenterology, Asian Institute of Gastroenterology Hospitals, Gachibowli, Hyderabad, India
| | - Mihai Rimbas
- Gastroenterology Department, Colentina Clinical Hospital, Bucharest, Romania
| | - Tomas Hucl
- Department of Gastroenterology and Hepatology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
| | - Abdenor Badaoui
- Department of Gastroenterology and Hepatology, Université catholique de Louvain, CHU UCL Namur, Yvoir, Belgium
| | - Ryan Law
- Department of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA
| | - Paolo Giorgio Arcidiacono
- Pancreatobiliary Endoscopy and Endosonography Division, IRCCS San Raffaele Scientific Institute, Milan, Italy
| | - Alberto Larghi
- Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, and Center for Endoscopic Research Therapeutics and Training, Catholic University, Rome, Italy
| | - Marc Giovannini
- Paoli-Calmettes Institute, Department of Gastrointestinal Disease, Marseille, France
| | - Mouen A Khashab
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, Maryland, USA
| | - Kenneth F Binmoeller
- Interventional Endoscopy Services, California Pacific Medical Center, San Francisco, California, USA
| | - Marc Barthet
- Department of Gastroenterology, Aix-Marseille Université, APHM, Hôpital Nord, Marseille, France
| | - Manuel Pérez-Miranda
- Gastroenterology Department, Hospital Universitario Rio Hortega, Valladolid, Spain
| | - Jeanin E van Hooft
- Department of Gastroenterology and Hepatology, Leiden University Medical Center, Leiden, The Netherlands
| | - Schalk W van der Merwe
- Department of Gastroenterology and Hepatology, University Hospitals Leuven, Leuven, Belgium
| |
Collapse
|
14
|
Jovani M, Al Ghamdi S, Bejjani M, Gandour B, Khashab MA. Switching the switch: endoscopic reversal of a biliopancreatic diversion. VideoGIE 2021; 6:464-467. [PMID: 34746537 PMCID: PMC8551544 DOI: 10.1016/j.vgie.2021.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Affiliation(s)
- Manol Jovani
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, Maryland
| | - Sarah Al Ghamdi
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, Maryland
| | - Michael Bejjani
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, Maryland
| | - Bachir Gandour
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, Maryland
| | - Mouen A Khashab
- Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, Baltimore, Maryland
| |
Collapse
|
15
|
Bhenswala P, Lakhana M, Gress FG, Andalib I. Novel Uses of Lumen-apposing Metal Stents: A Review of the Literature. J Clin Gastroenterol 2021; 55:641-651. [PMID: 34049379 DOI: 10.1097/mcg.0000000000001566] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The field of therapeutic endoscopy has seen many recent advancements. One such emerging field is the use of lumen-apposing metal stents (LAMS). Although a few LAMS have been developed, the most commonly reviewed and the only Food and Drug Administration (FDA)-approved LAMS is the Axios stent by Boston Scientific. In 2013, LAMS were initially approved by the FDA for the management of pancreatic fluid collection drainage in the presence walled-off necrosis. Pancreatic fluid collections are traditionally drained with either a plastic stent or a covered biliary self-expanding metal stent. Plastic stents have a double pigtail feature which prevents stent migration. However, their narrow lumen poses limitations as it can lead to early stent occlusion. Fully covered metal stents have larger diameters, allowing improved drainage and decreased stent occlusion but their tubular shape is prone to migration. Consequently, this results in leakage, and frequent retrievals. Over the years, due to their versatility, LAMS now have many off label uses. This includes management of gastric outlet obstruction, superior mesenteric artery syndrome, strictures, gallbladder drainage, and postsurgical collection drainage. In this review, we will be discussing the FDA approved and the nonapproved uses of LAMS.
Collapse
Affiliation(s)
- Prashant Bhenswala
- Department of Gastroenterology and Hepatology, Mount Sinai South Nassau, Oceanside, NY
| | | | | | | |
Collapse
|
16
|
Parvataneni S, Kumar VS, Khan YI, Deivert DE, Obuch J, Khara HS. Endoscopic Ultrasound-Directed Transgastric Endoscopic Retrograde Cholangiopancreatography for Removal of Cystic Duct Coils: A Novel Application of an Emerging Technique. ACG Case Rep J 2021; 8:e00576. [PMID: 34007855 PMCID: PMC8126554 DOI: 10.14309/crj.0000000000000576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2020] [Accepted: 12/02/2020] [Indexed: 11/17/2022] Open
Abstract
The altered anatomy of patients after Roux-en-Y gastric bypass (RYGB) surgery creates technical challenges for endoscopic and surgical treatment of gallstones. We present a unique case of a post-RYGB patient with complicated gallbladder surgery requiring coiling and embolization of the cystic duct for bile leak. The cystic duct coils migrated out into the bile duct forming a nidus for infection and biliary obstruction, which was resolved using the novel endoscopic ultrasound-directed transgastric routine endoscopic retrograde cholangiopancreatography technique, with successful transpapillary removal of cystic duct coils in RYGB anatomy.
Collapse
Affiliation(s)
- Swetha Parvataneni
- Department of Internal Medicine, Geisinger Lewistown Hospital, Lewistown, PA
| | - Vikas S. Kumar
- Department of Gastroenterology, Geisinger Lewistown Hospital, Lewistown, PA
| | - Yakub I. Khan
- Department of Gastroenterology and Hepatology, Geisinger Health System, Danville, PA
| | - Duane E. Deivert
- Department of Gastroenterology and Hepatology, Geisinger Health System, Danville, PA
| | - Joshua Obuch
- Department of Gastroenterology and Hepatology, Geisinger Health System, Danville, PA
| | - Harshit S. Khara
- Department of Gastroenterology and Hepatology, Geisinger Health System, Danville, PA
| |
Collapse
|