1
|
Senol YC, Orscelik A, Bilgin C, Kobeissi H, Ghozy S, Arul S, Kallmes DF, Kadirvel R. Safety and efficacy profile of off-label use of the Pipeline Embolization Device: A systematic review and meta-analysis. J Stroke Cerebrovasc Dis 2024; 33:107586. [PMID: 38242183 PMCID: PMC10939757 DOI: 10.1016/j.jstrokecerebrovasdis.2024.107586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 01/08/2024] [Accepted: 01/16/2024] [Indexed: 01/21/2024] Open
Abstract
OBJECTIVE The off-label utilization of the Pipeline Embolization Device (PED) is a common practice in numerous medical centers globally. Therefore, we conducted a systematic review and meta-analysis to evaluate the overall outcomes of this off-label usage of PEDs. METHODS PubMed, Web of Science, Ovid Medline, Ovid Embase, and Scopus were searched up to February 2023 using the Nested Knowledge platform to identify studies assessing the off-label use of PEDs. Any use of PED outside of the FDA-approved indication granted in 2018 is considered off-label use. Overall angiographic occlusion rates, ischemic and hemorrhagic complications, mortality, retreatment rates, and favorable clinic outcomes were included. Statistical analyses were performed to compare the overall outcome rates of anterior cerebral artery(ACA) vs. middle cerebral artery(MCA) and anterior vs posterior circulation subgroups. RESULTS We included 26 studies involving a total of 1,408 patients. The overall rate of complete occlusion was 80.3 % (95 % CI= 76.0-84.1). Subgroup analysis demonstrated a statistically significant difference in the rate of complete occlusion between anterior circulation (78.9 %) and posterior circulation (69.2 %) (p value=0.02). The rate of good clinical outcomes was 92.8 % (95 % CI= 88.8-95.4). The mortality rate was 1.4 % (95 % CI= 0.5-2.7). The overall rate of ischemic complications was 9.5 % (95 % CI= 7.7-11.6), with a comparable difference between anterior circulation (7.7 %) and posterior circulation (12.8 %) (p value=0.07). There was no statistically significant difference in MCA vs ACA subgroups in all parameters. CONCLUSIONS Off-label use of PEDs can be a safe and effective treatment option for intracranial aneurysms. However, there is a need for more prospective, high-quality, non-industry-funded registry studies and randomized trials to test the efficacy and safety of off-label usage of PEDs and to expand its indications.
Collapse
Affiliation(s)
- Yigit Can Senol
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA.
| | - Atakan Orscelik
- Department of Neurosurgery, Medical University of South Carolina, SC, USA
| | - Cem Bilgin
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Sherief Ghozy
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Santhosh Arul
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA
| | | | - Ramanathan Kadirvel
- Department of Neurologic Surgery, Mayo Clinic, Rochester, MN, USA; Department of Radiology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
2
|
Pineda-Castillo SA, Jones ER, Laurence KA, Thoendel LR, Cabaniss TL, Zhao YD, Bohnstedt BN, Lee CH. Systematic Review and Meta-Analysis of Endovascular Therapy Effectiveness for Unruptured Saccular Intracranial Aneurysms. STROKE (HOBOKEN, N.J.) 2024; 4:e001118. [PMID: 38846323 PMCID: PMC11152505 DOI: 10.1161/svin.123.001118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 11/13/2023] [Indexed: 06/09/2024]
Abstract
Background Currently, endovascular treatment of intracranial aneurysms (ICAs) is limited by low complete occlusion rates. The advent of novel endovascular technology has expanded the applicability of endovascular therapy; however, the superiority of novel embolic devices over the traditional Guglielmi detachable coils (GDCs) is still debated. We performed a systematic review of literature that reported Raymond-Roy occlusion classification (RROC) rates of modern endovascular devices to determine their immediate and follow-up occlusion effectiveness for the treatment of unruptured saccular ICAs. Methods A search was conducted using electronic databases (PUBMED, Cochrane, ClinicalTrials.gov, Web of Science). We retrieved studies published between 2000-2022 reporting immediate and follow-up RROC rates of subjects treated with different endovascular ICA therapies. We extracted demographic information of the treated patients and their reported angiographic RROC rates. Results A total of 80 studies from 15 countries were included for data extraction. RROC rates determined from angiogram were obtained for 21,331 patients (72.5% females, pooled mean age: 58.2 (95% CI: 56.8-59.6), harboring 22,791 aneurysms. The most frequent aneurysm locations were the internal carotid artery (46.4%, 95% CI: 41.9%-50.9%), the anterior communicating artery (26.4%, 95% CI: 22.5%-30.8%), the middle cerebral artery (24.5%, 95% CI:19.2%-30.8%) and the basilar tip (14.4%, 95% CI:11.3%-18.3%). The complete occlusion probability (RROC-I) was analyzed for GDCs, the Woven EndoBridge (WEB), and flow diverters. The RROC-I rate was the highest in balloon-assisted coiling (73.9%, 95% CI: 65.0%-81.2%) and the lowest in the WEB (27.8%, 95% CI:13.2%-49.2%). The follow-up RROC-I probability was homogenous in all analyzed devices. Conclusions We observed that the coil-based endovascular therapy provides acceptable rates of complete occlusion, and these rates are improved in balloon-assisted coils. Out of the analyzed devices, the WEB exhibited the shortest time to achieve >90% probability of follow-up complete occlusion (~18 months). Overall, the GDCs remain the gold standard for endovascular treatment of unruptured saccular aneurysms.
Collapse
Affiliation(s)
- Sergio A. Pineda-Castillo
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Evan R. Jones
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Keely A. Laurence
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Lauren R. Thoendel
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Tanner L. Cabaniss
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
| | - Yan D. Zhao
- Department of Biostatistics and Epidemiology, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USA
| | - Bradley N. Bohnstedt
- Department of Neurological Surgery, Indiana University School of Medicine, Indianapolis, IN, USA
| | - Chung-Hao Lee
- Biomechanics and Biomaterials Design Laboratory, School of Aerospace and Mechanical Engineering, The University of Oklahoma, Norman, OK, USA
- Department of Bioengineering, University of California Riverside, Riverside, CA, USA
| |
Collapse
|
3
|
El Naamani K, Saiegh FA, Chen CJ, Abbas R, Sioutas GS, Amllay A, Shehabeldine M, Gooch MR, Herial NA, Jabbour P, Rosenwasser RH, Tjoumakaris SI. Treatment of cerebral aneurysms with the FRED Jr flow-diverting stent: A case series and meta-analysis. Clin Neurol Neurosurg 2022; 223:107483. [DOI: 10.1016/j.clineuro.2022.107483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 09/29/2022] [Accepted: 10/18/2022] [Indexed: 11/30/2022]
|
4
|
Benalia VHC, Cortez GM, Brasiliense LBC, Starke RM, Killer-Oberpfalzer M, Lopes DK, Kan PT, Nogueira RG, Johnson JN, Pereira VM, Kilburg C, Khalili S, Hanel RA. Silk Vista Baby for the Treatment of Complex Posterior Inferior Cerebellar Artery Aneurysms. Neurosurgery 2022; 91:547-554. [PMID: 35830269 DOI: 10.1227/neu.0000000000002072] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 05/09/2022] [Indexed: 02/04/2023] Open
Abstract
BACKGROUND Treatment of small-caliber vessel lesions using flow diverters remains challenging because of vasculature's narrow luminal diameter and tortuosity. This in turn makes navigation and delivery of conventional devices with standard microcatheters more difficult. The Silk Vista Baby (SVB, Balt) flow diversion device was designed for ease of use in vessels with a smaller diameter, distal lesions, and 0.017 ″ microcatheter delivery systems. OBJECTIVE To report the outcomes of the SVB device on the treatment of posterior inferior cerebellar artery (PICA) aneurysms. METHODS Databases from different centers were retrospectively reviewed for PICA aneurysms treated with SVB. Demographic information, clinical presentation, radiographic characteristics, procedural complications, and immediate postprocedure outcomes were obtained. RESULTS Fourteen patients harboring 15 true PICA aneurysms were treated between January 2019 and June 2021. Nine were female (n = 9/14; 64.2%), and the mean age was 51 ± 14.9 years. Most patients had previously ruptured aneurysms, treated by another endovascular technique. Six aneurysms were located distally (n = 6/15; 40%). The mean neck size was 3 mm (SD 1.35, range 2.5-5 mm), whereas the mean PICA diameter was 1.6 mm (SD 0.26, range 1.5-1.7 mm). The mean length of follow-up was 6 months (SD 8.28, range 4.5-16 months). Treatment-related adverse events included 1 case of transient hypoesthesia. Two additional events were reported, but adjudicated as unrelated to the procedure. Complete occlusion, measured as Raymond-Roy class I, was achieved in all cases. CONCLUSION The SVB device was safely and effectively used in the treatment of PICA aneurysms. The smaller delivery system profile reduces the risk of procedure complications and creates new treatment options for distal lesions.
Collapse
Affiliation(s)
- Victor H C Benalia
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA.,Research Department, Jacksonville University, Jacksonville, Florida, USA
| | - Gustavo M Cortez
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA.,Research Department, Jacksonville University, Jacksonville, Florida, USA
| | - Leonardo B C Brasiliense
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA.,Department of Neurosurgery, College of Medicine Tucson, University of Arizona, Tucson, Arizona, USA
| | - Robert M Starke
- Department of Neurological Surgery, University of Miami School of Medicine, Miami, Florida, USA
| | - Monika Killer-Oberpfalzer
- Institute of Neurointervention/Department of Neurology, University Hospital Salzburg, Salzburg, Austria
| | - Demetrius K Lopes
- Brain and Spine Institute, Advocate Aurora Health, Chicago, Illinois, USA
| | - Peter T Kan
- Department of Neurosurgery, University of Texas Medical Branch, Galveston, Texas, USA
| | - Raul G Nogueira
- Neuroendovascular Service Marcus Stroke & Neuroscience Center, Grady Memorial Hospital, Atlanta, Georgia, USA
| | - Jeremiah N Johnson
- Department of Neurosurgery, University of California, Los Angeles, California, USA
| | - Vitor M Pereira
- Division of Neurosurgery, Departments of Surgery and Medical Imaging, St Michaels Hospital, University of Toronto, Toronto, Ontario, Canada
| | - Craig Kilburg
- Neurosurgery Department, University of Utah Health, Salt Lake City, Utah, USA
| | - Susan Khalili
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA
| | - Ricardo A Hanel
- Lyerly Neurosurgery, Baptist Neurological Institute, Jacksonville, Florida, USA
| |
Collapse
|
5
|
Dabhi N, Sarathy D, Snyder MH, Kellogg RT, Park MS. Flow Diverter Devices for Treatment of Intracranial Aneurysms in Small Parent Vessels – A Systematic Review of Literature. World Neurosurg 2022; 162:183-194.e7. [DOI: 10.1016/j.wneu.2022.02.034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 02/08/2022] [Indexed: 11/29/2022]
|
6
|
Lauzier DC, Root BK, Kayan Y, Almandoz JED, Osbun JW, Chatterjee AR, Whaley KL, Tipps ME, Moran CJ, Kansagra AP. Pipeline embolization of distal posterior inferior cerebellar artery aneurysms. Interv Neuroradiol 2021; 27:821-827. [PMID: 33892602 PMCID: PMC8673893 DOI: 10.1177/15910199211013195] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2021] [Revised: 03/04/2021] [Accepted: 03/29/2021] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND AND PURPOSE Flow diversion is commonly used to treat intracranial aneurysms in various regions of the cerebral vasculature, but is only approved for use in the internal carotid arteries. Treatment of distal PICA aneurysms with PED is sometimes performed but has not been well studied. Here, we report our experience with flow diversion of distal PICA aneurysms with PED. MATERIALS AND METHODS Clinical and angiographic data of eligible patients was retrospectively obtained and assessed for key demographic characteristics and clinical and angiographic outcomes. Principal outcomes included rates of aneurysm occlusion, ischemic or hemorrhagic complication, technical complication, and in-stent stenosis. RESULTS Three female and 2 male patients underwent placement of PED in the PICA for treatment of 5 distal PICA aneurysms. Clinical and angiographic follow-up was obtained for all patients. Complete aneurysm occlusion was observed in 100% (5/5) of treated aneurysms at 6 month and longest angiographic follow-up. While there were no ischemic or device-related complications, delayed hemorrhagic complications occurred in 20% (1/5) of patients. CONCLUSION Pipeline embolization of distal PICA aneurysms can be performed in select patients. Further study is necessary in larger cohorts to better define clinical scenarios in which flow diversion in the distal PICA should be considered.
Collapse
Affiliation(s)
- David C Lauzier
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Brandon K Root
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
| | - Yasha Kayan
- Division of Neurointerventional Radiology, Neuroscience Institute, Abbott Northwestern Hospital, Minneapolis, MN, USA
| | - Josser E Delgado Almandoz
- Division of Neurointerventional Radiology, Neuroscience Institute, Abbott Northwestern Hospital, Minneapolis, MN, USA
| | - Joshua W Osbun
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
- Department of Neurology, Washington University School of Medicine, St. Louis, MO, USA
- Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO, USA
| | - Arindam R Chatterjee
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
- Department of Neurology, Washington University School of Medicine, St. Louis, MO, USA
- Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO, USA
| | - Kayla L Whaley
- Neuroscience Institute, Abbott Northwestern Hospital, Minneapolis, MN, USA
| | - Megan E Tipps
- Neuroscience Institute, Abbott Northwestern Hospital, Minneapolis, MN, USA
| | - Christopher J Moran
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
- Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO, USA
| | - Akash P Kansagra
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, MO, USA
- Department of Neurology, Washington University School of Medicine, St. Louis, MO, USA
- Department of Neurological Surgery, Washington University School of Medicine, St. Louis, MO, USA
| |
Collapse
|
7
|
Porto GBF, Al Kasab S, Sattur MG, Almallouhi E, Lajthia O, Casey MA, Starke RM, Lanzino G, Ogilvy CS, Thomas AJ, Kim L, James RF, Levitt M, Spiotta AM. Endovascular Management of Distal Anterior Cerebral Artery Aneurysms: A Multicenter Retrospective Review. World Neurosurg 2021; 154:e421-e427. [PMID: 34284157 DOI: 10.1016/j.wneu.2021.07.055] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 07/12/2021] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Distal anterior cerebral artery aneurysms (DACAA) are a rare and difficult entity to manage. Endovascular treatment has evolved for safe and durable treatment of these lesions. The objective of this study is to report the safety, efficacy, and outcomes of endovascular treatment of DACAA. METHODS A retrospective review of DACAA endovascularly treated at 5 different institutions was performed. Data included demographics, rupture status, radiographic features, endovascular technique, complication rates, and long-term angiographic and clinical outcomes. A primary endpoint was a good clinical outcome (modified Rankin scale 0-2). Secondary endpoints included complications and radiographic occlusion at follow-up. RESULTS A total of 84 patients were reviewed. The mean age was 56, and 64 (71.4%) were female. Fifty-two (61.9%) aneurysms were ruptured. A good functional outcome was achieved in 59 patients (85.5%). Sixty (71.4%) aneurysms were treated with primary coiling, and the remaining 24 were treated with flow diversion. Adequate occlusion was achieved in 41 (95.3%) aneurysms treated with coiling, and 17 (89.5%) with flow diversion. There were total 11 (13%) complications. In the flow diversion category, there were 2, both related to femoral access. In the coiling category, there were 9: 5 thromboembolic, 3 ruptures, and 1 related to femoral access. CONCLUSION Endovascular treatment, and in particular, flow diversion for DACAA, is safe, feasible, and associated with good long-term angiographic and clinical outcomes.
Collapse
Affiliation(s)
- Guilherme B F Porto
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Medical University of South Carolina, Charleston, South Carolina, USA.
| | - Sami Al Kasab
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Mithun G Sattur
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Eyad Almallouhi
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Orgest Lajthia
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Michael A Casey
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Robert M Starke
- Department of Neurosurgery, Division of Neuroendovascular Surgery, University of Miami, Miami, Florida, USA
| | - Giuseppe Lanzino
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Mayo Clinic, Rochester, Minnesota, USA
| | - Christopher S Ogilvy
- Department of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Ajith J Thomas
- Department of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA
| | - Louis Kim
- Department of Neurosurgery, University of Washington, Seattle, Washington, USA
| | - Robert F James
- Department of Neurological Surgery, University of Louisville, Louisville, Kentucky, USA
| | - Michael Levitt
- Department of Neurosurgery, University of Washington, Seattle, Washington, USA
| | - Alejandro M Spiotta
- Department of Neurosurgery, Division of Neuroendovascular Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| |
Collapse
|
8
|
Bhogal P, Petrov A, Rentsenkhu G, Nota B, Ganzorig E, Regzengombo B, Jagusch S, Henkes E, Henkes H. Early clinical experience with the p48MW HPC and p64MW HPC flow diverters in the anterior circulation aneurysm using single anti-platelet treatment. Interv Neuroradiol 2021; 28:266-276. [PMID: 34233547 PMCID: PMC9178779 DOI: 10.1177/15910199211029503] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Background The p64MW HPC and p48MW HPC flow diverters have reduced thrombogenicity due
to hydrophilic coating. The purpose of this study was to evaluate its safety
and efficacy in Mongolian patients under single antiplatelet therapy (SAPT)
with prasugrel. Materials and methods We performed a retrospective review of patients enrolled into our
prospectively maintained database to identify all patients treated with
either the p48MW HPC or p64MW HPC under SAPT. We recorded baseline
demographics, aneurysm size and location, procedural complications,
angiographic and clinical results. Results 24 patients, (female = 21, 87.5%), age 48.2 ± 11.6 years (range 25–63)
underwent treatment of 30 aneurysms with either p64MW HPC or p48MW HPC. All
aneurysms were saccular with dome width 8.2 ± 6.5 (range 1.6–26.0 mm) and
dome height 7.6 ± 6.7 (range 1.6–30.0 mm). None of the aneurysms were
previously treated. The average PRU was 54.6 ± 31.2 (range 1–127) on
pre-operative VerifyNow testing. Angiographic follow-up was available for 13
patients (17 aneurysms), 183 ± 36 days post-procedure, at which point 64.7%
of aneurysms (n = 11/17) were completely occluded and 11.8% (n = 2/17) had
only neck remnants resulting in 76.5% of aneurysms being adequately occluded
A single intra-operative complication (4.2%) occurred however all patients
were mRS ≤1 at last follow-up. There were two post-operative complications
neither of which resulted in permanent neurological morbidity. There were no
instances of post-operative aneurysmal rupture or delayed parenchymal
haemorrhage. The overall mortality was 0%. Conclusion The efficacy and safety of p64MW HPC coated devices under SAPT is similar to
uncoated flow diverters that require DAPT.
Collapse
Affiliation(s)
| | - Andrey Petrov
- Vascular Neurosurgery Department, Russian Polenov Neurosurgical Institute, Branch of National Medical Research Center "Almazov", St. Petersburg, Russia
| | | | - Baatarjan Nota
- Department of Angiography, Shastin Central Hospital, Ulaanbaatar, Mongolia
| | - Erdenebat Ganzorig
- Department of Angiography, Shastin Central Hospital, Ulaanbaatar, Mongolia
| | | | | | - Elina Henkes
- Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany
| | - Hans Henkes
- Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany.,University Duisburg-Essen, Essen, Germany
| |
Collapse
|
9
|
Bhogal P, Makalanda H, Wong K, Keston P, Downer J, Du Plessis JC, Nania A, Simonato D, Fuschi M, Chong W, O'Reilly S, Rennie I. The Silk Vista Baby - The UK experience. Interv Neuroradiol 2021; 28:201-212. [PMID: 34078155 DOI: 10.1177/15910199211024061] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The Silk Vista Baby (SVB) flow diverter (FDS) is the only FDS deliverable via a 0.017 inch microcatheter and is specifically designed for the distal vasculature. We sought to evaluate the safety and efficacy of the SVB. MATERIALS AND METHODS We performed a retrospective review to identify SVB cases at 4 tertiary neurosurgical centres within the U.K. Clinical, procedural, angiographic and follow-up data were collected. RESULTS We identified 60 patients (35 female, 58%) of average age 54 ± 10.5 (range 30-72) with 61 aneurysms, 50 (81.9%) located in the anterior circulation. The majority of the aneurysms treated were unruptured (46, 75.4%) and saccular (46, 75.4%). Dome size was 6.2 ± 6.2 mm (range 1-36mm) and parent vessel diameter was 2.3 ± 0.4 mm (range 1.2-3.3 mm).An average number of 1.07 devices were implanted. Coils or other devices were implanted in 14 aneurysms (23.3%). At last angiographic follow-up (n = 55), 7.5 ± 4.2 months post-procedure, 32 aneurysms (57.1%) were graded as RRC I, 7 (12.5%) RRC II, and 17 RRC III (30.4%).Clinical complications, excluding death, were seen in 4 patients (6.8%) including 1 delayed aneurysm rupture and 3 symptomatic ischaemic events. Only one patient had permanent morbidity (mRS 1). 3 patients died during follow-up (5.1%); 2 deaths were related to the aneurysms (3.4%) - one ruptured dissecting MCA aneurysm, and one giant partially thrombosed posterior circulation aneurysm. 93% of patients were mRS ≤ 2 at last follow-up. CONCLUSION The SVB has high rates of technical success and an acceptable safety profile. Distal aneurysms may occlude slower due to relative oversizing of the devices.
Collapse
Affiliation(s)
- P Bhogal
- The Royal London Hospital, London, UK
| | | | - K Wong
- The Royal London Hospital, London, UK
| | - P Keston
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - J Downer
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - J C Du Plessis
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - A Nania
- Department of Clinical Neurosciences, Western General Hospital, Edinburgh, UK
| | - D Simonato
- Department of Interventional Neuroradiology, John Radcliffe Hospital, Oxford, UK
| | - M Fuschi
- Department of Interventional Neuroradiology, John Radcliffe Hospital, Oxford, UK
| | - W Chong
- Department of Interventional Neuroradiology, University Hospitals Coventry and Warwickshire, Warwickshire, UK
| | - S O'Reilly
- Department of Interventional Neuroradiology, The Royal Victoria Hospital, Belfast, UK
| | - I Rennie
- Department of Interventional Neuroradiology, The Royal Victoria Hospital, Belfast, UK
| |
Collapse
|
10
|
den Bergh FRAV, De Beule T, van Rooij WJ, Voormolen MH, Van der Zijden T, Stockx L, van Zwam WH, Fransen H. The p48 flow diverter: First clinical results in 25 aneurysms in three centers. Interv Neuroradiol 2021; 27:339-345. [PMID: 33164617 PMCID: PMC8190948 DOI: 10.1177/1591019920972213] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Revised: 10/13/2020] [Accepted: 10/18/2020] [Indexed: 01/29/2023] Open
Abstract
BACKGROUND The novel low-profile p48 flow diverter has been designed to treat aneurysms on small vessels of 1.75-3mm. We report our first clinical experiences. METHODS Between March 2018-January 2020, 22 patients with 25 aneurysms were treated with the p48 in 3 centers. One patient had 3 aneurysms covered by one p48 and one patient had 2 aneurysms. There were 5 men, 17 women, with a mean age of 55 years (median 59, range 29-73 years). RESULTS In 25 aneurysms, 24 p48 flow diverters were placed. In 1 patient additional coils were placed in the aneurysm. Procedural vessel rupture by the micro guidewire occurred in 2 patients and vessel rupture during p48 balloon dilatation occurred in 1 patient. Overall, the permanent morbidity rate was 13.6% (3 of 22, 95%CI 3.9-34.2%) and mortality was 4.5% (1 of 22, 95%CI <0.01-23.5%). Most complications were procedure-related and not device-specific. Of 22 patients with 25 aneurysms treated with p48, 18 patients with 20 aneurysms had angiographic follow-up after 5-18 months. Of 19 aneurysms, 10 were occluded and 7 showed a remnant. Two aneurysms were open after 6 months. Three aneurysms were still not occluded after 12, 14, and 18 months and these 3 were retreated. Retreatment rate was 16% (3 of 19) and the adequate occlusion rate was 90% (17 of 19). CONCLUSIONS Treatment of aneurysms in small-caliber vessels with the p48 is feasible and effective but is not without complications. More data is needed to establish indications, safety, and efficacy more accurately.
Collapse
Affiliation(s)
- FRA Van den Bergh
- Department of Radiology, Algemeen Ziekenhuis St Lucas, Gent, Belgium
| | - T De Beule
- Department of Radiology, Ziekenhuis Oost-Limburg, Genk, Belgium
| | - WJ van Rooij
- Department of Radiology, Algemeen Ziekenhuis Turnhout, Turnhout, Belgium
| | - MH Voormolen
- Department of Radiology, Universitair Ziekenhuis Antwerpen, Edegem, Belgium
| | - T Van der Zijden
- Department of Radiology, Universitair Ziekenhuis Antwerpen, Edegem, Belgium
| | - L Stockx
- Department of Radiology, Ziekenhuis Oost-Limburg, Genk, Belgium
| | - WH van Zwam
- Department of Radiology, Maastricht Universiteit Medisch Centrum, Maastricht, the Netherlands
| | - H Fransen
- Department of Radiology, Algemeen Ziekenhuis St Lucas, Gent, Belgium
| |
Collapse
|
11
|
Hou K, Li G, Lv X, Xu B, Xu K, Yu J. Delayed rupture of intracranial aneurysms after placement of intra-luminal flow diverter. Neuroradiol J 2020; 33:451-464. [PMID: 32851918 PMCID: PMC7788679 DOI: 10.1177/1971400920953299] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Though flow diverter is a safe and efficient modality, some patients can experience delayed aneurysmal rupture. The mechanism of delayed rupture is still obscure to us. METHODS We performed a systematic search in the PubMed database for patients with delayed rupture of intracranial aneurysms after flow diverter placement. RESULTS A total of 36 articles reporting on 60 patients were included in the final analysis. Of the 49 patients with description of presenting symptoms, six (12.2%) patients were incidentally diagnosed, 39 (87.8%) patients were admitted for aneurysmal rupture or mass effect. Multiple flow diverters were used in 38.3% (18/47) of the patients. Coil assistance was applied in 13.0% (7/54) of the patients. Delayed aneurysmal rupture led to intracranial hemorrhage or carotid-cavernous sinus fistula (CCF) in 76.8% (43/56) and 23.2% (13/56) of the patients, respectively. Of the 55 patients with description of outcome, 14 (25.5%) patients achieved good recovery, one (1.8%) patient was severely disabled, 40 (72.7%) patients died. All of the patients in the CCF group survived and experienced good recovery. CONCLUSION Increased intra-aneurysmal pressure, destabilization of the aneurysm wall by intra-aneurysmal thrombus, persistent residual intra-aneurysmal flow, characteristics of the specific aneurysm, and mechanical injury by the flow diverter might conjointly contribute to the final delayed rupture. There has been no established preventive measure to decrease the incidence of delayed rupture yet. The treatment and outcome depend on the presentation of delayed rupture. Patients presenting with aneurysm-related intracranial hemorrhage have a dismal outcome. Those presenting with CCFs usually have a satisfactory recovery.
Collapse
Affiliation(s)
- Kun Hou
- Department of Neurosurgery, The First Hospital of Jilin University, Changchun, China
| | - Guichen Li
- Department of Neurology, The First Hospital of Jilin University, Changchun, China
| | - Xianli Lv
- Department of Neurosurgery, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China
| | - Baofeng Xu
- Department of Neurosurgery, The First Hospital of Jilin University, Changchun, China
| | - Kan Xu
- Department of Neurosurgery, The First Hospital of Jilin University, Changchun, China
| | - Jinlu Yu
- Department of Neurosurgery, The First Hospital of Jilin University, Changchun, China
| |
Collapse
|
12
|
Cagnazzo F, Lefevre PH, Derraz I, Dargazanli C, Gascou G, di Carlo DT, Perrini P, Ahmed R, Hak JF, Riquelme C, Bonafe A, Costalat V. Flow-Diversion Treatment for Unruptured Nonsaccular Intracranial Aneurysms of the Posterior and Distal Anterior Circulation: A Meta-Analysis. AJNR Am J Neuroradiol 2020; 41:134-139. [PMID: 31924605 DOI: 10.3174/ajnr.a6352] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Accepted: 10/14/2019] [Indexed: 11/07/2022]
Abstract
BACKGROUND Treatment management and outcomes of unruptured nonsaccular aneurysms are different compared with their saccular counterparts. PURPOSE Our aim was to analyze the outcomes after flow diversion among nonsaccular unruptured lesions. DATA SOURCES A systematic search of 3 data bases (2005-2019) was performed according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. STUDY SELECTION We included studies reporting flow diversion for nonsaccular unruptured aneurysms of the posterior and distal anterior circulations. Anterior circulation lesions were included if located distal to the petrocavernous and supraclinoid ICA (MCA, A1, anterior communicating artery, A2). Giant dolichoectatic holobasilar lesions were excluded because of their poor treatment outcomes. DATA ANALYSIS Aneurysm occlusion and complication rates were calculated (random effects meta-analysis). DATA SYNTHESIS We included 15 studies (213 aneurysms). The long-term adequate occlusion rate was 85.3% (137/168; 95% CI, 78.2%-92.4%; I2 = 42.3%). Treatment-related complications were 17.4% (41/213; 95% CI, 12.45%-22.4%; I2 = 0%). Overall, 15% (37/213; 95% CI, 10%-20%; I2 = 0%) were ischemic events. Procedure-related morbidity was 8% (20/213; 95% CI, 5%-12%; I2 = 0%). Fusiform or dissecting types had comparable adequate occlusion (116/146 = 83%; 95% CI, 74%-92%; I2 = 48% versus 33/36 = 89%; 95% CI, 80%-98%; I2 = 0%; P = .31) and complication rates (35/162 = 17%; 95% CI, 10%-25%; I2 = 24% versus 11/51 = 19%; 95% CI, 10%-31%; I2 = 0%; P = .72). Aneurysm size (>10 versus ≤10 mm) was independently associated with a higher rate of complications (OR = 6.6; 95% CI, 1.3-15; P = .02). The rate of ischemic events after discontinuation of the antiplatelet therapy was 5% (5/93; 95% CI, 2%-9%; I2 = 0%). LIMITATIONS Small and retrospective studies were available for this meta-analysis. CONCLUSIONS Unruptured nonsaccular aneurysms located in the posterior and distal anterior circulations can be effectively treated with flow diversion. Nevertheless, treatment-related complications are not negligible, with about 15% ischemic events and 8% morbidity. Larger size (>10 mm) significantly increases the risk of procedure-related adverse events.
Collapse
Affiliation(s)
- F Cagnazzo
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - P-H Lefevre
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - I Derraz
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - C Dargazanli
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - G Gascou
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - D T di Carlo
- Department of Neurosurgery (D.T.d.C., P.P.), University of Pisa, Pisa, Italy
| | - P Perrini
- Department of Neurosurgery (D.T.d.C., P.P.), University of Pisa, Pisa, Italy
| | - R Ahmed
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - J F Hak
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - C Riquelme
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - A Bonafe
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| | - V Costalat
- From the Neuroradiology Department (F.C., P.-H.L., I.D., C.D., G.G., R.A., J.F.H., C.R., A.B., V.C.), CHU Gui De Chauliac, Montpellier, France
| |
Collapse
|
13
|
AlMatter M, Henkes E, Sirakov A, Aguilar Pérez M, Hellstern V, Serna Candel C, Ganslandt O, Henkes H. The p48 MW flow modulation device for treatment of unruptured, saccular intracranial aneurysms: a single center experience from 77 consecutive aneurysms. CVIR Endovasc 2020; 3:39. [PMID: 32776195 PMCID: PMC7415468 DOI: 10.1186/s42155-020-00131-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 06/02/2020] [Indexed: 12/28/2022] Open
Abstract
Background The p48 MW Flow Modulation Device (phenox, Bochum Germany) is a low profile flow diverter stent (FDS), designed for implantation into intracranial arteries with a diameter of less than 3.5 mm. Objective To evaluate the safety and efficacy of the p48 MW FDS in the treatment of unruptured aneurysms located at intracranial arteries with less than 3.5 mm diameter based on a retrospective analysis from a single tertiary neurovascular center. Methods A prospectively maintained database was retrospectively reviewed to identify all cases of intracranial saccular aneurysms treated electively with the p48 MW device. Records were made of basic demographics, aneurysmal characteristics, interventional procedures, adverse events, clinical outcomes and occlusion rates on angiographic follow-ups. Results A total of 77 aneurysms and 74 patients were included. The mean size of the treated aneurysms was 3.5 ± 2.4 mm and the mean aspect ratio was 1.3 ± 0.4. A total of 80 endovascular procedures were performed with a total of 12 (15%) adverse events leading to two (2.5%) permanent morbidities/mortalities. Technical issues were encountered in 3 (3.9%) cases. Adequate occlusion of the treated aneurysm was recorded in 55.6% and 63.9% on the first and latest available DSA follow-ups, respectively. There were no cases of side-branch occlusion. Conclusions The p48 MW is an easy-to-use implant with very good safety margins. Side branch occlusion and significant in-stent stenosis are infrequently encountered. The time from implantation to sufficient aneurysm occlusion takes longer than with FDS with lower porosity.
Collapse
Affiliation(s)
- Muhammad AlMatter
- Neuroradiologische Klinik, Klinikum Stuttgart, Kriegsbergstraße 60, 70174, Stuttgart, Germany.
| | - Elina Henkes
- Neuroradiologische Klinik, Klinikum Stuttgart, Kriegsbergstraße 60, 70174, Stuttgart, Germany
| | - Alexander Sirakov
- Neuroradiologische Klinik, Klinikum Stuttgart, Kriegsbergstraße 60, 70174, Stuttgart, Germany.,Radiology Department, UH St Ivan Rilski, Sofia, Bulgaria
| | - Marta Aguilar Pérez
- Neuroradiologische Klinik, Klinikum Stuttgart, Kriegsbergstraße 60, 70174, Stuttgart, Germany
| | - Victoria Hellstern
- Neuroradiologische Klinik, Klinikum Stuttgart, Kriegsbergstraße 60, 70174, Stuttgart, Germany
| | - Carmen Serna Candel
- Neuroradiologische Klinik, Klinikum Stuttgart, Kriegsbergstraße 60, 70174, Stuttgart, Germany
| | - Oliver Ganslandt
- Neurochirurgische Klinik, Klinikum Stuttgart, Stuttgart, Germany
| | - Hans Henkes
- Neuroradiologische Klinik, Klinikum Stuttgart, Kriegsbergstraße 60, 70174, Stuttgart, Germany.,Medizinische Fakultät der Universität Duisburg-Essen, Essen, Germany
| |
Collapse
|
14
|
Campos JK, Cheaney Ii B, Lien BV, Zarrin DA, Vo CD, Colby GP, Lin LM, Coon AL. Advances in endovascular aneurysm management: flow modulation techniques with braided mesh devices. Stroke Vasc Neurol 2020; 5:1-13. [PMID: 32411402 PMCID: PMC7213520 DOI: 10.1136/svn-2020-000347] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Accepted: 02/28/2020] [Indexed: 02/07/2023] Open
Abstract
Flow diverters and flow disruption technology, alongside nuanced endovascular techniques, have ushered in a new era of treating cerebral aneurysms. Here, we provide an overview of the latest flow modulation devices and highlight their clinical applications and outcomes.
Collapse
Affiliation(s)
- Jessica K Campos
- Department of Neurosurgery, University of California Irvine School of Medicine, Orange, California, USA
| | - Barry Cheaney Ii
- Oregon Health and Science University School of Medicine, Portland, Oregon, USA
| | - Brian V Lien
- Department of Neurosurgery, University of California Irvine School of Medicine, Orange, California, USA
| | - David A Zarrin
- Neurosurgery, Johns Hopkins University, Baltimore, Maryland, USA
| | - Chau D Vo
- Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Geoffrey P Colby
- UCLA Neurosurgery, Ronald Reagan UCLA Medical Center, Los Angeles, California, USA
| | - Li-Mei Lin
- Carondelet Neurological Institute, St. Joseph's Hospital, Carondelet Health Network, Tucson, Arizona, United States
| | - Alexander L Coon
- Carondelet Neurological Institute, St. Joseph's Hospital, Carondelet Health Network, Tucson, Arizona, United States
| |
Collapse
|
15
|
Chiu AHY, Phillips TJ. Future Directions of Flow Diverter Therapy. Neurosurgery 2020; 86:S106-S116. [PMID: 31838531 PMCID: PMC6911736 DOI: 10.1093/neuros/nyz343] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Accepted: 05/26/2019] [Indexed: 12/20/2022] Open
Abstract
The treatment of intracranial aneurysms has undergone a few very significant paradigm shifts in its history. Needless to say, microsurgery and surgical clipping served as the initial basis for successful treatment of these lesions. The pursuit of endovascular therapy subsequently arose from the desire to reduce the invasiveness of therapy. While the first breakthrough arose with Guido Guglielmi's invention of the detachable platinum coil, commercialized flow diverter therapy represents a disruptive therapy with a completely different paradigm for aneurysmal obliteration. This has not only altered the distribution of aneurysmal management strategies, but also opened the gateway to the treatment of previously inoperable lesions. With the basic flow diverter stent technology now considered an integral part of the neurointerventional armamentarium, we now consider what may lay in the future - including potential directions for research with regards to case selection; the location and type of aneurysms which may become routinely treatable; and modifications to the flow diverter, which may increase its utility and safety in terms of size, structural design, and surface modifications.
Collapse
Affiliation(s)
- Albert Ho Yuen Chiu
- Neurological Intervention & Imaging Service of Western Australia, Sir Charles Gairdner, Fiona Stanley and Royal Perth Hospitals, WA Health, Perth, Australia
- Division of Medicine, University of Western Australia, Perth, Australia
| | - Timothy John Phillips
- Neurological Intervention & Imaging Service of Western Australia, Sir Charles Gairdner, Fiona Stanley and Royal Perth Hospitals, WA Health, Perth, Australia
| |
Collapse
|
16
|
Bhogal P, Bleise C, Chudyk J, Lylyk I, Viso R, Perez N, Henkes H, Lylyk P. The p48MW Flow Diverter-Initial Human Experience. Clin Neuroradiol 2019; 31:135-145. [PMID: 31435722 PMCID: PMC7943536 DOI: 10.1007/s00062-019-00827-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Accepted: 07/30/2019] [Indexed: 02/06/2023]
Abstract
Background and Purpose The use of flow diverters to treat aneurysms arising from small caliber parent vessels has been reported. This article reports the results of the first in experiences with the p48MW (p48 Movable Wire) in humans, a device specifically designed to target vessels 1.75–3 mm in diameter. Methods This monocentric study retrospectively reviewed the prospectively maintained database to identify all patients treated with the p48MW device between January 2017 and January 2019 at this institution. Patient demographics, aneurysm characteristics, angiographic and clinical follow-up were recorded as well as complications. Results A total of 25 patients (20 female) with an average age of 55 ± 12.9 years (range 34–84) with 25 aneurysms were identified. The majority of the aneurysms was located in the anterior circulation (19/25, 76%). The average aneurysm dome width was 3.98 ± 3.6 mm (range 1.2–13 mm). Complete occlusion was seen in 18/24 (75%) aneurysms with neck remnants in 1/24 (4.2%) and continued aneurysm filling seen in the remaining cases (5/24, 20.8%). Adequate occlusion was seen in 79.2% of aneurysms (Raymond Roy Classification [RRC] grade I or II) during the follow-up period. There was a single technical complication with inappropriate deployment of the first p48MW. There was a single clinical complication (4%); however, the patient made a complete recovery (modified Rankin Scale [mRS] 0) and one patient died secondary to uncontrollable status epilepticus following acute subarachnoid hemorrhage unrelated to the treatment. Conclusion The p48MW is safe and effective for the treatment of aneurysms including those arising from distal vessels.
Collapse
Affiliation(s)
- P Bhogal
- The Royal London Hospital, Whitechapel Road, E1 1BB, London, UK.
| | - C Bleise
- Neuroradiological Clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - J Chudyk
- Neuroradiological Clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - I Lylyk
- Neuroradiological Clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - R Viso
- Neuroradiological Clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - N Perez
- Neuroradiological Clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| | - H Henkes
- Medical Faculty, University Duisburg-Essen, Essen, Germany.,Neuroradiological Clinic, Klinikum Stuttgart, Stuttgart, Germany
| | - P Lylyk
- Neuroradiological Clinic, Clinica Sagrada Familia, ENERI, Buenos Aires, Argentina
| |
Collapse
|
17
|
Schob S, Hoffmann KT, Richter C, Bhogal P, Köhlert K, Planitzer U, Ziganshyna S, Lindner D, Scherlach C, Nestler U, Meixensberger J, Quäschling U. Flow diversion beyond the circle of Willis: endovascular aneurysm treatment in peripheral cerebral arteries employing a novel low-profile flow diverting stent. J Neurointerv Surg 2019; 11:1227-1234. [PMID: 31088939 PMCID: PMC6902074 DOI: 10.1136/neurintsurg-2019-014840] [Citation(s) in RCA: 44] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 04/02/2019] [Accepted: 04/08/2019] [Indexed: 11/05/2022]
Abstract
Background Flow diversion (FD) has emerged as superior minimally invasive therapy for cerebral aneurysms. However, aneurysms of small peripheral vessel segments have not yet been adequately treatable. More specifically, currently established devices necessitate large microcatheters which impede atraumatic maneuvering. The Silk Vista Baby (SVB), a novel flow diverter, offers the as yet unique feature of deliverability via a 0.017 inch microcatheter. This study reports our first experience with the SVB in challenging intracranial vessels employing a vessel-specific tailored microcatheter strategy. Materials and methods 25 patients (27 aneurysms) were prospectively included. A total of 30 SVBs were employed, predominantly targeting demanding aneurysms of the anterior communicating artery complex. The efficacy of the FD was assessed using two-dimensional vector-based perfusion and conventional digital subtraction angiography (DSA) after implantation and at the first follow-up at 3 months. The first follow-up was available in 22 patients. Results All devices were implanted without technical or clinical complications. Eleven treatments were performed using the recommended Headway 17. In 14 interventions the even more maneuverable Excelsior SL10 was used, which was previously tried and tested for safety ’in vitro’ as an alternative delivery system. Aneurysmal influx was strongly reduced after implantation. All parent vessels remained patent. 17/27 aneurysms were completely occluded at first follow-up (∼2.7 months), 6/27 aneurysms showed decreased influx or delayed washout and one remained unchanged. In three cases follow-up DSAs are remaining. Conclusions SVB provides enhanced controllability in vulnerable segments beyond the circle of Willis. Smaller variants (2.25 mm and 2.75 mm) can safely be implanted via the superiorly navigable Excelsior SL10. Hence, the SVB represents the next evolutionary step in minimally invasive treatment of cerebral aneurysms.
Collapse
Affiliation(s)
- Stefan Schob
- Department for Neuroradiology, University Hospital Leipzig, Leipzig, Germany
| | - Karl-Titus Hoffmann
- Department for Neuroradiology, University Hospital Leipzig, Leipzig, Germany
| | - Cindy Richter
- Department for Neuroradiology, University Hospital Leipzig, Leipzig, Germany
| | - Pervinder Bhogal
- Department of Interventional Neuroradiology, Royal London Hospital, London, UK
| | - Katharina Köhlert
- Department for Neurosurgery, University Hospital Leipzig, Leipzig, Saxony, Germany
| | - Uwe Planitzer
- Department for Neurosurgery, University Hospital Leipzig, Leipzig, Saxony, Germany
| | - Svitlana Ziganshyna
- Department for Anesthesiology, University Hospital Leipzig, Leipzig, Germany
| | - Dirk Lindner
- Department for Neurosurgery, University Hospital Leipzig, Leipzig, Saxony, Germany
| | - Cordula Scherlach
- Department for Neuroradiology, University Hospital Leipzig, Leipzig, Germany
| | - Ulf Nestler
- Department for Neurosurgery, University Hospital Leipzig, Leipzig, Saxony, Germany
| | - Jürgen Meixensberger
- Department for Neurosurgery, University Hospital Leipzig, Leipzig, Saxony, Germany
| | - Ulf Quäschling
- Department for Neuroradiology, University Hospital Leipzig, Leipzig, Germany
| |
Collapse
|
18
|
Bhogal P, Wong K, Uff C, Wadley J, Makalanda HL. The Silk Vista Baby: Initial experience and report of two cases. Interv Neuroradiol 2019; 25:530-538. [PMID: 30931672 DOI: 10.1177/1591019919839196] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
In this report, we present two cases using a novel flow diverter, the Silk Vista Baby, to treat aneurysms successfully, both ruptured and unruptured, that would have been difficult to treat using alternative flow diverters. We describe the clinical and radiological features, outcome and the unique features of the Silk Vista Baby flow diverter.
Collapse
Affiliation(s)
- Pervinder Bhogal
- Department of Interventional Neuroradiology, The Royal London Hospital, London, UK
| | - Ken Wong
- Department of Interventional Neuroradiology, The Royal London Hospital, London, UK
| | - Christopher Uff
- Department of Neurosurgery, The Royal London Hospital, London, UK
| | - John Wadley
- Department of Neurosurgery, The Royal London Hospital, London, UK
| | - Hegoda Ld Makalanda
- Department of Interventional Neuroradiology, The Royal London Hospital, London, UK
| |
Collapse
|