1
|
Li S, Du J, Huang Y, Hao D, Zhao Z, Chang Z, Zhu J, Wang X, Duan Y, He B. Comparison of the efficacies of TINAVI robot-assisted surgery and conventional open surgery for Levine-Edward type IIA (postreduction) hangman fractures. Sci Rep 2023; 13:15934. [PMID: 37741877 PMCID: PMC10517983 DOI: 10.1038/s41598-023-43136-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Accepted: 09/20/2023] [Indexed: 09/25/2023] Open
Abstract
The objective was to compare the clinical efficacy of percutaneous pedicle screw internal fixation with the aid of the TINAVI orthopaedic surgery robot with that of traditional open surgery for Levine-Edward type IIA (postreduction) hangman fractures and to evaluate the safety and efficacy of the TINAVI robot-assisted orthopaedic surgery procedure. The clinical data of 60 patients with Levine-Edward type IIA (postreduction) hangman fractures treated surgically from June 2015 to February 2022 were analysed retrospectively. Among these patients, 25 were treated with percutaneous pedicle screw fixation under TINAVI (the robot group), and 35 were treated with pedicle screw implantation assisted by a conventional C-arm X-ray machine (the traditional operation group). The pedicle screw placement grade was evaluated according to the Rampersaud scale. The correct rate of pedicle screw placement was calculated. The invasion of adjacent facet joints, VAS score (Visual Analogue Scale), NDI score (Neck Disability Index), SF-36 score (36-Item Short-Form Health Survey questionnaire), EQ-5D score (EuroQol-5 dimensions questionnaire) and operation-related data were recorded, and patients were followed up. All patients were followed up for an average of 15.0 ± 3.4 months. The accuracy of screw placement in the robot group was higher than that in the traditional operation group, while the rates of intraoperative blood loss and invasion of the facet joint were lower and the incision length and length of hospital stay were shorter. On the 3rd day after the operation, the VAS score in the robot group was significantly higher than that in the traditional operation group, but there was no significant difference in the NDI score. On the 3rd day after the operation, the SF-36 and EQ-5 questionnaire scores of the robot group were better than those of the traditional operation group. No complications occurred in any of the patients. Postoperative cervical X-ray showed that the cervical vertebra was stable, and there was no fracture, angle or displacement. Postoperative CT showed that all fractures healed, and the average healing time was 3.4 months. The treatment of Levine-Edward IIA (postrepositioning) hangman fractures with percutaneous pedicle fixation assisted by the TINAVI orthopaedic surgery robot can significantly improve screw placement accuracy with a low rate of invasion of the adjacent facet joint, a short operation time, a low bleeding rate, and high patient satisfaction. Although there are still many disadvantages, it still has good prospects for application.
Collapse
Affiliation(s)
- Shuai Li
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
- Medical College, Yan'an University, Yan'an, Shaanxi, China
| | - Jinpeng Du
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - Yunfei Huang
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - Dingjun Hao
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - Zhigang Zhao
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - Zhen Chang
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - Jingwen Zhu
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - Xiaodong Wang
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - Yongchao Duan
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China
| | - BaoRong He
- Department of Spine Surgery, Honghui Hospital, Xi'an Jiaotong University, Youyidong Road, Xi'an, 710000, Shaanxi, China.
| |
Collapse
|
2
|
Pojskić M, Bopp M, Nimsky C, Carl B, Saβ B. Initial Intraoperative Experience with Robotic-Assisted Pedicle Screw Placement with Cirq ® Robotic Alignment: An Evaluation of the First 70 Screws. J Clin Med 2021; 10:jcm10245725. [PMID: 34945020 PMCID: PMC8703981 DOI: 10.3390/jcm10245725] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2021] [Revised: 12/03/2021] [Accepted: 12/03/2021] [Indexed: 01/02/2023] Open
Abstract
BACKGROUND Robot-guided spine surgery is based on a preoperatively planned trajectory that is reproduced in the operating room by the robotic device. This study presents our initial experience with thoracolumbar pedicle screw placement using Brainlab's Cirq® surgeon-controlled robotic arm (BrainLab, Munich, Germany). METHODS All patients who underwent robotic-assisted implantation of pedicle screws in the thoracolumbar spine were included in the study. Our workflow, consisting of preoperative imagining, screw planning, intraoperative imaging with automatic registration, fusion of the preoperative and intraoperative imaging with a review of the preplanned screw trajectories, robotic-assisted insertion of K-wires, followed by a fluoroscopy-assisted insertion of pedicle screws and control iCT scan, is described. RESULTS A total of 12 patients (5 male and 7 females, mean age 67.4 years) underwent 13 surgeries using the Cirq® Robotic Alignment Module for thoracolumbar pedicle screw implantation. Spondylodiscitis, metastases, osteoporotic fracture, and spinal canal stenosis were detected. A total of 70 screws were implanted. The mean time per screw was 08:27 ± 06:54 min. The mean time per screw for the first 7 surgeries (first 36 screws) was 16:03 ± 09:32 min and for the latter 6 surgeries (34 screws) the mean time per screw was 04:35 ± 02:11 min (p < 0.05). Mean entry point deviation was 1.9 ± 1.23 mm, mean deviation from the tip of the screw was 2.61 ± 1.6 mm and mean angular deviation was 3.5° ± 2°. For screw-placement accuracy we used the CT-based Gertzbein and Robbins System (GRS). Of the total screws, 65 screws were GRS A screws (92.85%), one screw was a GRS B screw, and two further screws were grade C. Two screws were D screws (2.85%) and underwent intraoperative revision. There were no perioperative deficits. CONCLUSION Brainlab's Cirq® Robotic Alignment surgeon-controlled robotic arm is a safe and beneficial method for accurate thoracolumbar pedicle screw placement with high accuracy.
Collapse
Affiliation(s)
- Mirza Pojskić
- Department of Neurosurgery, University of Marburg, 65199 Marburg, Germany; (M.B.); (C.N.); (B.C.); (B.S.)
- Correspondence: ; Tel.: +49-642-1586-9848
| | - Miriam Bopp
- Department of Neurosurgery, University of Marburg, 65199 Marburg, Germany; (M.B.); (C.N.); (B.C.); (B.S.)
- Marburg Center for Mind, Brain and Behavior (MCMBB), 65199 Marburg, Germany
| | - Christopher Nimsky
- Department of Neurosurgery, University of Marburg, 65199 Marburg, Germany; (M.B.); (C.N.); (B.C.); (B.S.)
- Marburg Center for Mind, Brain and Behavior (MCMBB), 65199 Marburg, Germany
| | - Barbara Carl
- Department of Neurosurgery, University of Marburg, 65199 Marburg, Germany; (M.B.); (C.N.); (B.C.); (B.S.)
- Marburg Center for Mind, Brain and Behavior (MCMBB), 65199 Marburg, Germany
- Department of Neurosurgery, Helios Dr. Horst Schmidt Kliniken, 65199 Wiesbaden, Germany
| | - Benjamin Saβ
- Department of Neurosurgery, University of Marburg, 65199 Marburg, Germany; (M.B.); (C.N.); (B.C.); (B.S.)
| |
Collapse
|