1
|
Fu Y, Bian X, Zou R, Jin R, Leng X, Fan F, Wei S, Cui X, Xiang J, Guan S. Hemodynamic alterations of flow diverters on aneurysms at the fetal posterior communicating artery: A simulation study using CFD to compare the surpass streamline, pipeline flex, and tubridge devices. J Neuroradiol 2024; 51:74-81. [PMID: 37442272 DOI: 10.1016/j.neurad.2023.07.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 07/03/2023] [Accepted: 07/10/2023] [Indexed: 07/15/2023]
Abstract
PURPOSE Traditional flow diverters (FDs) for treating aneurysms at the fetal posterior communicating artery are unsatisfactory. Surpass Streamline is a novel FD with different mesh characteristics; however, the outcomes for such aneurysms remain unclear. This study aimed to compare hemodynamic alterations induced by Surpass Streamline, Pipeline Flex, and Tubridge devices and explore possible strategies for aneurysms at the fetal posterior communicating artery. METHODS Two simulated aneurysms (Case 1, Case 2) were constructed from digital subtraction angiography (DSA). The three FDs were virtually deployed, and hemodynamic analysis based on computational fluid dynamics was performed. Hemodynamic parameters, including the sac-averaged velocity magnitude (Velocity), high-flow volume (HFV), and wall shear stress (WSS), were compared between each FD and the untreated model (control). Surpass Streamline was performed in real life for two aneurysms and the clinical outcomes were collected for analysis. RESULTS Compared to the control, the Surpass resulted in the most significant reduction in flow. In Case 1, the Velocity, HFV, and WSS were reduced by 51.6%, 78.1%, and 64.3%, respectively. In Case 2, the Velocity, HFV, and WSS were reduced by 48.0%, 81.1%, and 65.3%, respectively. Tubridge showed slightly larger changes in hemodynamic parameters than Pipeline. In addition, our analysis suggested that metal coverage was correlated with the WSS, Velocity, and HFV. The postoperative DSA showed that the aneurysm was nearly occluded in Case 1 and decreased in Case 2. CONCLUSION Compared to that with the Pipeline and Tubridge, the Surpass resulted in the greatest reduction in hemodynamic parameters and might be effective for aneurysms at the fetal posterior communicating artery. Virtual FD deployment and computational fluid dynamics analysis may be used to predict the treatment outcomes.
Collapse
Affiliation(s)
- Yu Fu
- Department of Neurointervention Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xin Bian
- ArteryFlow Technology Co., Ltd., Hangzhou, China
| | - Rong Zou
- ArteryFlow Technology Co., Ltd., Hangzhou, China
| | - Rongbo Jin
- ArteryFlow Technology Co., Ltd., Hangzhou, China
| | | | - Feng Fan
- Department of Neurointervention Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Sen Wei
- Department of Neurointervention Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Xuan Cui
- Department of Neurointervention Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | | | - Sheng Guan
- Department of Neurointervention Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China.
| |
Collapse
|
2
|
Ghaith AK, Greco E, Rios-Zermeno J, El-Hajj VG, Perez-Vega C, Ghanem M, Kashyap S, Fox WC, Huynh TJ, Sandhu SS, Ohlsson M, Elmi-Terander A, Bendok BR, Bydon M, Tawk RG. Safety and efficacy of the pipeline embolization device for treatment of small vs. large aneurysms: a systematic review and meta-analysis. Neurosurg Rev 2023; 46:284. [PMID: 37882896 DOI: 10.1007/s10143-023-02192-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/06/2023] [Accepted: 10/17/2023] [Indexed: 10/27/2023]
Abstract
Flow diversion with the pipeline embolization device (PED) is increasingly used to treat intracranial aneurysms with high obliteration rates and low morbidity. However, long-term (≥ 1 year) angiographic and clinical outcomes still require further investigation. The aim of this study was to compare the occlusion and complication rates for small (< 10 mm) versus large (10-25 mm) aneurysms at long-term following treatment with PED. A systematic review and meta-analysis were performed in compliance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. We conducted a comprehensive search of English language databases including Ovid MEDLINE and Epub Ahead of Print, In-Process, and Daily, Ovid EMBASE, Ovid Cochrane Central Register of Controlled Trials, Ovid Cochrane Database of Systematic Reviews, and Scopus. Our studies included a minimum of 10 patients treated with PED for small vs. large aneurysms and with at least 12 months of follow-up. The primary safety endpoint was the rate of clinical complications measured by the occurrence of symptomatic stroke (confirmed clinically and radiographically), intracranial hemorrhage, or aneurysmal rupture. The primary efficacy endpoint was the complete aneurysm occlusion rate. Our analysis included 19 studies with 1277 patients and 1493 aneurysms. Of those, 1378 aneurysms met our inclusion criteria. The mean age was 53.9 years, and most aneurysms were small (89.75%; N = 1340) in women (79.1%; N = 1010). The long-term occlusion rate was 73% (95%, CI 65 to 80%) in small compared to 84% (95%, CI 76 to 90%) in large aneurysms (p < 0.01). The symptomatic thromboembolic complication rate was 5% (95%, CI 3 to 9%) in small compared to 7% (95%, CI 4 to 13%) in large aneurysms (p = 0.01). The rupture rate was 2% vs. 4% (p = 0.92), and the rate of intracranial hemorrhage was 2% vs. 4% (p = 0.96) for small vs. large aneurysms, respectively; however, these differences were not statistically significant. The long-term occlusion rate after PED treatment is higher in large vs. small aneurysms. Symptomatic thromboembolic rates with stroke are also higher in large vs. small aneurysms. The difference in the rates of aneurysm rupture and intracranial hemorrhage was insignificant. Although the PED seems a safe and effective treatment for small and large aneurysms, further studies are required to clarify how occlusion rate and morbidity are affected by aneurysm size.
Collapse
Affiliation(s)
- Abdul Karim Ghaith
- Mayo Clinic Neuro-Informatics Laboratory, Mayo Clinic, Rochester, MN, USA
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
| | - Elena Greco
- Department of Neurological Surgery, Mayo Clinic, Jacksonville, FL, USA
| | | | - Victor Gabriel El-Hajj
- Mayo Clinic Neuro-Informatics Laboratory, Mayo Clinic, Rochester, MN, USA
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Carlos Perez-Vega
- Department of Neurological Surgery, Mayo Clinic, Jacksonville, FL, USA
| | - Marc Ghanem
- Mayo Clinic Neuro-Informatics Laboratory, Mayo Clinic, Rochester, MN, USA
| | - Samir Kashyap
- Department of Neurological Surgery, Mayo Clinic, Jacksonville, FL, USA
| | - W Christopher Fox
- Department of Neurological Surgery, Mayo Clinic, Jacksonville, FL, USA
| | - Thien J Huynh
- Department of Neurological Surgery, Mayo Clinic, Jacksonville, FL, USA
| | | | - Marcus Ohlsson
- Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | | | - Bernard R Bendok
- Department of Neurological Surgery, Mayo Clinic, Phoenix, AZ, USA
| | - Mohamad Bydon
- Mayo Clinic Neuro-Informatics Laboratory, Mayo Clinic, Rochester, MN, USA
- Department of Neurological Surgery, Mayo Clinic, Rochester, MN, USA
| | - Rabih G Tawk
- Department of Neurological Surgery, Mayo Clinic, Jacksonville, FL, USA.
| |
Collapse
|
3
|
Vivanco-Suarez J, Mendez-Ruiz A, Farooqui M, Bekelis K, Singer JA, Javed K, Altschul DJ, Fifi JT, Matsoukas S, Cooper J, Al-Mufti F, Gross B, Jankowitz B, Kan PT, Hafeez M, Orru E, Dajles A, Galecio-Castillo M, Zevallos CB, Wakhloo AK, Ortega-Gutierrez S. Safety and efficacy of the surpass streamline for intracranial aneurysms (SESSIA): A multi-center US experience pooled analysis. Interv Neuroradiol 2023; 29:589-598. [PMID: 35934939 PMCID: PMC10549718 DOI: 10.1177/15910199221118148] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 07/09/2022] [Accepted: 07/17/2022] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND AND PURPOSE Flow diversion has established as standard treatment for intracranial aneurysms, the Surpass Streamline is the only FDA-approved braided cobalt/chromium alloy implant with 72-96 wires. We aimed to determine the safety and efficacy of the Surpass in a post-marketing large United States cohort. MATERIALS AND METHODS This is a retrospective multicenter study of consecutive patients treated with the Surpass for intracranial aneurysms between 2018 and 2021. Baseline demographics, comorbidities, and aneurysm characteristics were collected. Efficacy endpoint included aneurysm occlusion on radiographic follow-up. Safety endpoints were major ipsilateral ischemic stroke or treatment-related death. RESULTS A total of 277 patients with 314 aneurysms were included. Median age was 60 years, 202 (73%) patients were females. Hypertension was the most common comorbidity in 156 (56%) patients. The most common location of the aneurysms was the anterior circulation in 89% (279/314). Mean aneurysm dome width was 5.77 ± 4.75 mm, neck width was 4.22 ± 3.83 mm, and dome/neck ratio was 1.63 ± 1.26. Small-sized aneurysms were 185 (59%). Single device was used in 94% of the patients, mean number of devices per patient was 1.06. At final follow-up, complete obliteration rate was 81% (194/239). Major stroke and death were encountered in 7 (3%) and 6 (2%) cases, respectively. CONCLUSION This is the largest cohort study using a 72-96 wire flow diverter. The Surpass Streamline demonstrated a favorable safety and efficacy profile, making it a valuable option for treating not only large but also wide-necked small and medium-sized intracranial aneurysms.
Collapse
Affiliation(s)
- Juan Vivanco-Suarez
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | - Alan Mendez-Ruiz
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | - Mudassir Farooqui
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | - Kimon Bekelis
- Department of Neurological Surgery, Good Samaritan Hospital Medical Center, West Islip, NY, United States
| | - Justin A Singer
- Department of Neurological Surgery, Spectrum Health, Grand Rapids, MI, United States
| | - Kainaat Javed
- Department of Neurological Surgery, Montefiore Medical Center, Bronx, NY, United States
| | - David J Altschul
- Department of Neurological Surgery, Montefiore Medical Center, Bronx, NY, United States
| | - Johanna T Fifi
- Department of Neurological Surgery, The Mount Sinai Hospital, New York, NY, United States
| | - Stavros Matsoukas
- Department of Neurological Surgery, The Mount Sinai Hospital, New York, NY, United States
| | - Jared Cooper
- Department of Neurology, Neurosurgery & Radiology, Westchester Medical Center and New York Medical College, Valhalla, NY, United States
| | - Fawaz Al-Mufti
- Department of Neurology, Neurosurgery & Radiology, Westchester Medical Center and New York Medical College, Valhalla, NY, United States
| | - Bradley Gross
- Department of Endovascular Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, United States
| | - Brian Jankowitz
- Department of Endovascular Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, United States
| | - Peter T Kan
- Department of Neurological Surgery, University of Texas Medical Branch, Galveston, TX, United States
| | - Muhammad Hafeez
- Department of Neurological Surgery, University of Texas Medical Branch, Galveston, TX, United States
| | - Emanuele Orru
- Department of Interventional Neuroradiology, Lahey Hospital & Medical Center, Burlington, MA, United States
| | - Andres Dajles
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | - Milagros Galecio-Castillo
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | - Cynthia B Zevallos
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| | - Ajay K Wakhloo
- Department of Interventional Neuroradiology, Lahey Hospital & Medical Center, Burlington, MA, United States
| | - Santiago Ortega-Gutierrez
- Department of Neurology, Neurosurgery & Radiology, The University of Iowa Hospitals and Clinics, Iowa City, IA, United States
| |
Collapse
|
4
|
Teranishi K, Mishima Y, Taniguchi T, Fujii T, Nonaka S, Kitamura T, Kondo A, Oishi H. Preliminary Experience of the Surpass Streamline Flow Diverter for Large and Giant Unruptured Internal Carotid Artery Aneurysms. Neurol Med Chir (Tokyo) 2022; 62:451-457. [PMID: 36070961 PMCID: PMC9637403 DOI: 10.2176/jns-nmc.2022-0167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
As of January 2021, the Surpass Streamline (SS) is the most recently approved flow diverter in Japan. A total of 28 Japanese patients, including 9 clinical trial patients, with 28 large or giant unruptured internal carotid artery (ICA) aneurysms, underwent SS embolization at Juntendo University Hospital. Procedural failure occurred in two patients due to the difficulty to navigate the device in the tortuous parent artery. Therefore, 26 patients with 26 aneurysms were available for clinical and anatomical assessments. Patients' mean age was 62.6 years (range 46-86), and 24 patients (92.3%) were female. Mean aneurysm size and neck width were 15.4 mm and 7.7 mm, respectively, with 20 saccular and 6 fusiform aneurysms. Seven aneurysms were symptomatic due to the aneurysmal mass effect. Twenty patients underwent a 6-month follow-up angiography to evaluate the degree of occlusion. Anatomical outcomes were 12 (60%) complete occlusion (CO), 4 (20%) residual neck (RN), and 4 (20%) residual aneurysm. Favorable aneurysm occlusion consisted of CO, and RN was achieved in 16 (80.0%). There were no significant device stenoses. Aneurysmal mass effect improved in one and was unchanged in eight patients. There were three device-related complications, namely, delayed aneurysm rupture, minor ischemic stroke, and device occlusion (11.5%). One patient with minor ischemic stroke fully recovered before 30 days, and our series showed 7.7% risk of major ipsilateral stroke and neurological death at 30 days. The SS embolization for large and giant unruptured ICA aneurysms offers satisfactory anatomical and clinical outcomes with a low risk of device-related complications.
Collapse
Affiliation(s)
- Kosuke Teranishi
- Department of Neurosurgery, Juntendo University, Faculty of Medicine
| | - Yumiko Mishima
- Department of Neurosurgery, Juntendo University, Faculty of Medicine
| | - Takahiko Taniguchi
- Department of Neuroendovascular Therapy, Juntendo University, Faculty of Medicine
| | - Takashi Fujii
- Department of Neuroendovascular Therapy, Juntendo University, Faculty of Medicine
| | - Senshu Nonaka
- Department of Neurosurgery, Juntendo University, Faculty of Medicine
| | - Takayuki Kitamura
- Department of Neurosurgery, Juntendo University, Faculty of Medicine.,Department of Neuroendovascular Therapy, Juntendo University, Faculty of Medicine
| | - Akihide Kondo
- Department of Neurosurgery, Juntendo University, Faculty of Medicine
| | - Hidenori Oishi
- Department of Neurosurgery, Juntendo University, Faculty of Medicine.,Department of Neuroendovascular Therapy, Juntendo University, Faculty of Medicine
| |
Collapse
|
5
|
Vivanco-Suarez J, Feigen C, Javed K, Dardick JM, Holland R, Mendez-Ruiz A, Ortega-Gutierrez S, Haranhalli N, Altschul DJ. Dataset on flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, and Surpass Streamline for intracranial aneurysms. Data Brief 2022; 42:108299. [PMID: 35669008 PMCID: PMC9163419 DOI: 10.1016/j.dib.2022.108299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 05/10/2022] [Accepted: 05/16/2022] [Indexed: 11/27/2022] Open
Abstract
Flow diversion is an evolving endovascular modality for treating intracranial aneurysms. Although rare, serious adverse events following flow diversion may include ischemic stroke, intracranial hemorrhage, or delayed rupture of the treated aneurysm. This dataset describes 141 flow diversion procedures performed with the Pipeline Embolization Device, Pipeline Flex, or Surpass Streamline on 126 subjects with intracranial aneurysms [1]. The retrospective data were collected from electronic medical records at two large tertiary centers. Baseline patient data included age, sex, and medical comorbidities. The dataset also describes aneurysm characteristics including laterality, anatomic location, morphology, dome height, and neck width. In addition, digital subtraction images showing the internal carotid artery tortuosity were included for aneurysms in the anterior cerebral circulation [2]. Procedural data include case duration, radiation exposure, number of flow diverters deployed, and complications encountered during deployment. In addition, data related to the duration of hospitalization and postoperative adverse events are included. Finally, time to follow up and rates of total aneurysm obliteration at first and second postoperative visits are included. This data is propensity score matching are included. This data is presented as a starting point for future prospective comparisons in the safety and efficacy of flow diverters as more devices become approved and commercially available.
Collapse
Affiliation(s)
- Juan Vivanco-Suarez
- Department of Neurological Surgery, Montefiore Medical Center, 3316 Rochambeau Avenue, Bronx, NY 10467, United States
| | - Chaim Feigen
- Department of Neurology, Neurosurgery and Radiology, The University of Iowa Hospitals and Clinics, 200 Hawkins Dr, Iowa City, IA 52242, United States
| | - Kainaat Javed
- Department of Neurological Surgery, Montefiore Medical Center, 3316 Rochambeau Avenue, Bronx, NY 10467, United States
| | - Joseph M Dardick
- Department of Neurological Surgery, Montefiore Medical Center, 3316 Rochambeau Avenue, Bronx, NY 10467, United States
| | - Ryan Holland
- Department of Neurological Surgery, Montefiore Medical Center, 3316 Rochambeau Avenue, Bronx, NY 10467, United States
| | - Alan Mendez-Ruiz
- Department of Neurology, Neurosurgery and Radiology, The University of Iowa Hospitals and Clinics, 200 Hawkins Dr, Iowa City, IA 52242, United States
| | - Santiago Ortega-Gutierrez
- Department of Neurology, Neurosurgery and Radiology, The University of Iowa Hospitals and Clinics, 200 Hawkins Dr, Iowa City, IA 52242, United States
| | - Neil Haranhalli
- Department of Neurological Surgery, Montefiore Medical Center, 3316 Rochambeau Avenue, Bronx, NY 10467, United States
| | - David J Altschul
- Department of Neurological Surgery, Montefiore Medical Center, 3316 Rochambeau Avenue, Bronx, NY 10467, United States
| |
Collapse
|