Santhumayor B, Karkare S, Kothare S, Rodgers S. Evaluating vagus nerve stimulation treatment with heart rate monitoring in pediatric patients with intractable epilepsy.
Childs Nerv Syst 2022;
38:547-556. [PMID:
34837500 DOI:
10.1007/s00381-021-05416-0]
[Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 11/16/2021] [Indexed: 01/11/2023]
Abstract
PURPOSE
Vagus nerve stimulators (VNS) have emerged as an effective treatment modality for pediatric patients suffering from intractable, drug-resistant epilepsy. Newer devices, AspireSR™ Model 106 and the SenTiva™ Model 1000 (VNS TherapyⓇ, LivaNova™), contain an "auto-stimulation" feature that detects ictal tachycardia and transmits pulsations to attenuate seizures. However, the exact benefits of auto-stimulation compared to its risks still merit further exploration. This study evaluates the utility of these specific devices in a heterogeneous population of pediatric and young adult patients with intractable epilepsy.
METHODS
This is a retrospective chart review of 55 patients who underwent either VNS insertion with or without an auto-stimulation-enabled VNS device at a single level four epilepsy center. Seizure frequency, seizure subtype, side effects, and change in anti-seizure medication load both before and after VNS implantations were collected from patient self-reporting at the time of VNS insertion and 12 months following implantation. Information regarding output current, auto-stimulation current, duty cycling, and auto-stimulation threshold of the device was obtained from documented VNS interrogation for patients with auto-stimulation-enabled VNS devices.
RESULTS
Patients with auto-stimulation-enabled VNS devices had a mean 56.0% (SD = 0.414) seizure frequency reduction 12 months post-VNS insertion, while patients without auto-stimulation-enabled VNS devices had a mean 41.6% (SD = 0.456) seizure frequency reduction during the same interval. The mean seizure frequency reduction 12 months post-VNS insertion for patients with a SenTiva™ 1000 model was 66.0% (SD = 0.426). For patients with auto-stimulation-enabled VNS devices, post-treatment seizure reduction was significantly correlated with daily auto-stimulation activation (R = 0.432, p = 0.025).
CONCLUSION
This study supports the clinical safety and utility of auto-stimulation-enabled VNS models, specifically the SenTiva™ 1000, in treating pediatric patients with intractable epilepsy of various subtypes and etiologies. Further research is needed to evaluate the sustained impact of auto-stimulation on long-term outcomes (≥ 2 years follow-up post-VNS).
Collapse