• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4594147)   Today's Articles (3926)   Subscriber (49325)
For: Sharif MN, Wyse DG, Rothschild JM, Gillis AM. Changes in pacing lead impedance over time predict lead failure. Am J Cardiol 1998;82:600-3. [PMID: 9732887 DOI: 10.1016/s0002-9149(98)00414-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Number Cited by Other Article(s)
1
Bhuva AN, Moralee R, Brunker T, Lascelles K, Cash L, Patel KP, Lowe M, Sekhri N, Alpendurada F, Pennell DJ, Schilling R, Lambiase PD, Chow A, Moon JC, Litt H, Baksi AJ, Manisty CH. Evidence to support magnetic resonance conditional labelling of all pacemaker and defibrillator leads in patients with cardiac implantable electronic devices. Eur Heart J 2021;43:2469-2478. [PMID: 34435642 PMCID: PMC9259370 DOI: 10.1093/eurheartj/ehab350] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Revised: 04/20/2021] [Accepted: 05/28/2021] [Indexed: 11/14/2022]  Open
2
Dahiya G, Wetzel A, Kyvernitakis A, Gevenosky L, Williams R, Shah M, Farah V, Doyle M, Biederman RW. Impact of magnetic resonance imaging on functional integrity of non-conditional cardiovascular implantable electronic devices. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2021;44:1312-1319. [PMID: 34133778 DOI: 10.1111/pace.14298] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Revised: 06/03/2021] [Accepted: 06/14/2021] [Indexed: 11/30/2022]
3
Nazarian S, Hansford R, Rahsepar AA, Weltin V, McVeigh D, Gucuk Ipek E, Kwan A, Berger RD, Calkins H, Lardo AC, Kraut MA, Kamel IR, Zimmerman SL, Halperin HR. Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices. N Engl J Med 2017;377:2555-2564. [PMID: 29281579 PMCID: PMC5894885 DOI: 10.1056/nejmoa1604267] [Citation(s) in RCA: 205] [Impact Index Per Article: 29.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
4
Russo RJ, Costa HS, Silva PD, Anderson JL, Arshad A, Biederman RWW, Boyle NG, Frabizzio JV, Birgersdotter-Green U, Higgins SL, Lampert R, Machado CE, Martin ET, Rivard AL, Rubenstein JC, Schaerf RHM, Schwartz JD, Shah DJ, Tomassoni GF, Tominaga GT, Tonkin AE, Uretsky S, Wolff SD. Assessing the Risks Associated with MRI in Patients with a Pacemaker or Defibrillator. N Engl J Med 2017;376:755-764. [PMID: 28225684 DOI: 10.1056/nejmoa1603265] [Citation(s) in RCA: 251] [Impact Index Per Article: 35.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
5
A case series of anomalous high pacing lead impedances in normally functioning leads. HeartRhythm Case Rep 2015;1:449-452. [PMID: 28491604 PMCID: PMC5419708 DOI: 10.1016/j.hrcr.2015.06.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]  Open
6
Udo EO, van Hemel NM, Zuithoff NPA, Dijk WA, Hooijschuur CAM, Doevendans PA, Moons KGM. Pacemaker follow-up: are the latest guidelines in line with modern pacemaker practice? Europace 2012;15:243-51. [DOI: 10.1093/europace/eus310] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]  Open
7
Canabal A, Hortigüela V, Raigal A, Sánchez P, Sánchez M, Marco C, Fernández E, Márquez JA. [Foreseeable variation in parameters measured at implant and follow-up of permanent pacemaker active fixation electrodes]. Med Intensiva 2011;36:270-6. [PMID: 22192317 DOI: 10.1016/j.medin.2011.11.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Revised: 10/18/2011] [Accepted: 11/01/2011] [Indexed: 11/16/2022]
8
Johnson WB, Braly A, Cobian K, Craig MB, Voegtlin L, Haddad T, McVenes R. Effect of insulation material in aging pacing leads: comparison of impedance and other electricals: time-dependent pacemaker insulation changes. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2011;35:51-7. [PMID: 21972882 DOI: 10.1111/j.1540-8159.2011.03230.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
9
Nazarian S, Hansford R, Roguin A, Goldsher D, Zviman MM, Lardo AC, Caffo BS, Frick KD, Kraut MA, Kamel IR, Calkins H, Berger RD, Bluemke DA, Halperin HR. A prospective evaluation of a protocol for magnetic resonance imaging of patients with implanted cardiac devices. Ann Intern Med 2011;155:415-24. [PMID: 21969340 PMCID: PMC4337840 DOI: 10.7326/0003-4819-155-7-201110040-00004] [Citation(s) in RCA: 224] [Impact Index Per Article: 17.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]  Open
10
Ichiyanagi H, Shiga Y, Ooiwa N, Nishiki K, Hara K, Sato Y, Hayashi H, Inden Y. Variation in Lead Impedance according to Pacemaker Analyzing Systems. J Arrhythm 2010. [DOI: 10.1016/s1880-4276(10)80012-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]  Open
11
Anderson SE, Skadsberg ND, Laske TG, Benditt DG, Iaizzo PA. Variation in Pacing Impedance: Impact of Implant Site and Measurement Method. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2007;30:1076-82. [PMID: 17725749 DOI: 10.1111/j.1540-8159.2007.00816.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
12
Roberts PR. Follow up and optimisation of cardiac pacing. Heart 2005;91:1229-34. [PMID: 16103575 PMCID: PMC1769065 DOI: 10.1136/hrt.2004.054528] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]  Open
13
Laske TG, Vieau SA, Skadsberg ND, Iaizzo PA. High Pacing Impedances: Are You Overtorquing Your Leads? PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2005;28:883-91. [PMID: 16176524 DOI: 10.1111/j.1540-8159.2005.00192.x] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
PrevPage 1 of 1 1Next