Suzuki N, Kozuma K, Ueno Y, Nagaoka K, Kyono H, Ishikawa S, Watanabe H, Yokoyama N, Takeshita S, Isshiki T. Serial quantitative coronary analyses for the evaluation of one-year change in saphenous vein grafts.
Ann Thorac Surg 2008;
85:525-9. [PMID:
18222257 DOI:
10.1016/j.athoracsur.2007.09.040]
[Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2007] [Revised: 09/20/2007] [Accepted: 09/20/2007] [Indexed: 10/22/2022]
Abstract
BACKGROUND
A paucity of data exists with respect to changes in whole saphenous vein grafts (SVGs) despite accelerated atherosclerosis within grafted saphenous vein conduits. In the present study, we evaluated the one-year change in SVGs by means of quantitative coronary analysis.
METHODS
This study enrolled consecutive 52 patients with 109 SVGs, who underwent coronary artery bypass graft surgery successfully. A follow-up study was performed in 33 patients with 65 SVGs after one year because 16 SVGs were obstructed (baseline, 8; follow-up period, 8), and 15 patients with 28 SVGs dropped out within one year.
RESULTS
Both minimal and mean lumen diameters decreased significantly (3.17 +/- 0.64 mm vs 2.41 +/- 0.57 mm, p < 0.001; 3.70 +/- 0.69 mm vs 2.92 +/- 0.70 mm, p < 0.001; respectively). Graft length also decreased significantly (107.1 +/- 25.8 vs 100.6 +/- 25.2 mm, p < 0.001). The graft shortening rate (graft shortening length/baseline graft length x 100) was greater than 5% in 33 vessels (51%) and greater than 10% in 23 vessels (35%). Coronary risk factors (smoking, diabetes mellitus, hypertension, dyslipidemia) did not reveal significant relationship with late loss of minimal and mean lumen diameters.
CONCLUSIONS
The present study showed a considerable and uniform lumen loss of SVGs after one year, irrespective of coronary risk factors. Graft length shortening was seen more than elongation.