1
|
Lehto L, Liikanen E, Melkko T, Ebeling T, Kouri T. An interactive two-step training and management model of point-of-care glucose testing in northern Finland. Int J Circumpolar Health 2016; 70:329-38. [DOI: 10.3402/ijch.v70i3.17830] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
2
|
Abstract
Accurate and rapid diagnostic tests can help identify high-risk patients with ACS among those presenting to the emergency department with chest pain. Such tests can also differentiate low-risk patients with chest pain who are suitable for early emergency department discharge. In this article, Drs Amsterdam and Deedwania elucidate the varieties of ACS, their pathophysiology, and the methods used for diagnosis. The authors also explore the potential of point-of-care testing for cardiac injury markers in the timely and accurate identification of ACS.
Collapse
|
3
|
Stoot LJ, Cairns NA, Cull F, Taylor JJ, Jeffrey JD, Morin F, Mandelman JW, Clark TD, Cooke SJ. Use of portable blood physiology point-of-care devices for basic and applied research on vertebrates: a review. CONSERVATION PHYSIOLOGY 2014; 2:cou011. [PMID: 27293632 PMCID: PMC4806731 DOI: 10.1093/conphys/cou011] [Citation(s) in RCA: 69] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2013] [Revised: 02/25/2014] [Accepted: 03/03/2014] [Indexed: 05/03/2023]
Abstract
Non-human vertebrate blood is commonly collected and assayed for a variety of applications, including veterinary diagnostics and physiological research. Small, often non-lethal samples enable the assessment and monitoring of the physiological state and health of the individual. Traditionally, studies that rely on blood physiology have focused on captive animals or, in studies conducted in remote settings, have required the preservation and transport of samples for later analysis. In either situation, large, laboratory-bound equipment and traditional assays and analytical protocols are required. The use of point-of-care (POC) devices to measure various secondary blood physiological parameters, such as metabolites, blood gases and ions, has become increasingly popular recently, due to immediate results and their portability, which allows the freedom to study organisms in the wild. Here, we review the current uses of POC devices and their applicability to basic and applied studies on a variety of non-domesticated species. We located 79 individual studies that focused on non-domesticated vertebrates, including validation and application of POC tools. Studies focused on a wide spectrum of taxa, including mammals, birds and herptiles, although the majority of studies focused on fish, and typical variables measured included blood glucose, lactate and pH. We found that calibrations for species-specific blood physiology values are necessary, because ranges can vary within and among taxa and are sometimes outside the measurable range of the devices. In addition, although POC devices are portable and robust, most require durable cases, they are seldom waterproof/water-resistant, and factors such as humidity and temperature can affect the performance of the device. Overall, most studies concluded that POC devices are suitable alternatives to traditional laboratory devices and eliminate the need for transport of samples; however, there is a need for greater emphasis on rigorous calibration and validation of these units and appreciation of their limitations.
Collapse
Affiliation(s)
- Lauren J. Stoot
- Fish Ecology and Conservation Physiology Laboratory, Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, Canada K1S 5B6
- Corresponding author: Fish Ecology and Conservation Physiology Laboratory, Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, Canada K1S 5B6. Tel: +1 613 520 2600.
| | - Nicholas A. Cairns
- Fish Ecology and Conservation Physiology Laboratory, Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, Canada K1S 5B6
| | - Felicia Cull
- Fish Ecology and Conservation Physiology Laboratory, Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, Canada K1S 5B6
| | - Jessica J. Taylor
- Fish Ecology and Conservation Physiology Laboratory, Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, Canada K1S 5B6
| | - Jennifer D. Jeffrey
- Department of Biology, University of Ottawa, 30 Marie Curie, Ottawa, Ontario, Canada K1N 6N5
| | - Félix Morin
- Department of Biology, University of Ottawa, 30 Marie Curie, Ottawa, Ontario, Canada K1N 6N5
| | - John W. Mandelman
- John H. Prescott Marine Laboratory, New England Aquarium, Central Wharf, Boston, MA 02110-3399, USA
| | - Timothy D. Clark
- Australian Institute of Marine Science, PMB 3, Townsville MC, Townsville 4810, Queensland, Australia
| | - Steven J. Cooke
- Fish Ecology and Conservation Physiology Laboratory, Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, Canada K1S 5B6
- Institute of Environmental Science, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario, Canada K1S 5B6
| |
Collapse
|
4
|
Point-of-care tests in suspected acute myocardial infarction: A systematic review. Int J Cardiol 2013; 168:5355-62. [DOI: 10.1016/j.ijcard.2013.08.002] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2013] [Revised: 07/20/2013] [Accepted: 08/03/2013] [Indexed: 11/22/2022]
|
5
|
Pecoraro V, Germagnoli L, Banfi G. Point-of-care testing: where is the evidence? A systematic survey. ACTA ACUST UNITED AC 2013; 52:313-24. [PMID: 24038608 DOI: 10.1515/cclm-2013-0386] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2013] [Accepted: 07/26/2013] [Indexed: 11/15/2022]
Abstract
Abstract
Point-of-care testing (POCT) has had rapid technological development and their use is widespread in clinical laboratories to assure reduction of turn-around-time and rapid patient management in some clinical settings where it is important to make quick decisions. Until now the papers published about the POCT have focused on the reliability of the technology used and their analytical accuracy. We aim to perform a systematic survey of the evidence of POCT efficacy focused on clinical outcomes, selecting POCT denoted special analytes characterized by possible high clinical impact. We searched in Medline and Embase. Two independent reviewers assessed the eligibility, extracted study details and assessed the methodological quality of studies. We analyzed 84 studies for five POCT instruments: neonatal bilirubin, procalcitonin, intra-operative parathyroid hormone, troponin and blood gas analysis. Studies were at high risk of bias. Most of the papers (50%) were studies of correlation between the results obtained by using POCT instruments and those obtained by using laboratory instruments. These data showed a satisfactory correlation between methods when similar analytical reactions were used. Only 13% of the studies evaluated the impact of POCT on clinical practice. POCT decreases the time elapsed for making decisions on patient management but the clinical outcomes have never been adequately evaluated. Our work shows that, although POCT has the potential to provide beneficial patient outcome, further studies may be required, especially for defining its real utility on clinical decision making.
Collapse
Affiliation(s)
- Valentina Pecoraro
- Clinical Epidemiologic Unit, IRCCS Galeazzi Orthopedic Institute, Milan, Italy
| | | | - Giuseppe Banfi
- Clinical Epidemiologic Unit, IRCCS Galeazzi Orthopedic Institute, Milan, Italy
- Department of Biomedical Science for Health, University of Milan, Milan, Italy
| |
Collapse
|
6
|
Liikanen E, Lehto L. Training of nurses in point-of-care testing: a systematic review of the literature. J Clin Nurs 2013; 22:2244-52. [DOI: 10.1111/jocn.12235] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/24/2012] [Indexed: 11/26/2022]
Affiliation(s)
- Eeva Liikanen
- Institute of Health Sciences; University of Oulu, Oulu and Senior Lecturer; Tampere University of Applied Sciences, Tampere; Oulu Finland
| | - Liisa Lehto
- Laboratory; Oulu University Hospital; Oulu Finland
| |
Collapse
|
7
|
Aldous SJ. Cardiac biomarkers in acute myocardial infarction. Int J Cardiol 2012; 164:282-94. [PMID: 22341694 DOI: 10.1016/j.ijcard.2012.01.081] [Citation(s) in RCA: 79] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2011] [Revised: 12/16/2011] [Accepted: 01/26/2012] [Indexed: 01/11/2023]
Abstract
Each year, a large number of patients are seen in the Emergency Department with presentations necessitating investigation for possible acute myocardial infarction. Patients can be stratified by symptoms, risk factors and electrocardiogram results but cardiac biomarkers also have a prime role both diagnostically and prognostically. This review summarizes both the history of cardiac biomarkers as well as currently available (established and novel) assays. Cardiac troponin, our current "gold standard" biomarker criterion for the diagnosis of myocardial infarction has high sensitivity and specificity for this diagnosis and therapies instituted in patients with elevated troponin have been shown to influence outcomes. Other markers of myocardial necrosis, inflammation and neurohormonal activity have also been shown to have either diagnostic or prognostic utility, but none have been shown to be superior to troponin. The measurement of multiple biomarkers and the use of point of care markers may accelerate current diagnostic protocols for the assessment of such patients.
Collapse
|
8
|
Yu J, Wang S, Ge L, Ge S. A novel chemiluminescence paper microfluidic biosensor based on enzymatic reaction for uric acid determination. Biosens Bioelectron 2011; 26:3284-9. [PMID: 21257303 DOI: 10.1016/j.bios.2010.12.044] [Citation(s) in RCA: 138] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2010] [Revised: 12/25/2010] [Accepted: 12/27/2010] [Indexed: 10/18/2022]
Abstract
In this work, chemiluminescence (CL) method was combined with microfluidic paper-based analytical device (μPAD) to establish a novel CL μPAD biosensor for the first time. This novel CL μPAD biosensor was based on enzyme reaction which produced H(2)O(2) while decomposing the substrate and the CL reaction between rhodanine derivative and generated H(2)O(2) in acid medium. Microchannels in μPAD were fabricated by cutting method. And the possible CL assay principle of this CL μPAD biosensor was explained. Rhodanine derivative system was used to reach the purpose of high sensitivity and well-defined signal for this CL μPAD biosensor. And the optimum reaction conditions were investigated. The quantitative determination of uric acid could be achieved by this CL μPAD biosensor with accurate and satisfactory result. And this biosensor could provide good reproducible results upon storage at 4°C for at least 10 weeks. The successful integration of μPAD and CL reaction made the final biosensor inexpensive, easy-to-use, low-volume, and portable for uric acid determination, which also greatly reduces the cost and increases the efficiency required for an analysis. We believe this simple, practical CL μPAD biosensor will be of interest for use in areas such as disease diagnosis.
Collapse
Affiliation(s)
- Jinghua Yu
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, PR China.
| | | | | | | |
Collapse
|
9
|
Garay F, Kisiel G, Fang A, Lindner E. Surface plasmon resonance aided electrochemical immunosensor for CK-MB determination in undiluted serum samples. Anal Bioanal Chem 2010; 397:1873-81. [PMID: 20449577 PMCID: PMC2930610 DOI: 10.1007/s00216-010-3736-2] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Revised: 04/02/2010] [Accepted: 04/07/2010] [Indexed: 12/01/2022]
Abstract
This article presents a simple chronoamperometric immunosensor for the quantitative assessment of creatine kinase MB (CK-MB) in 50 microL undiluted serum samples. The immunosensor consists of gold working and counter electrodes patterned onto a glass chip by thin-film photolithography and an external Ag|AgCl reference electrode. The detection limit (DL) of the chronoamperometric method is 13 ng mL(-1) (DL = 2xRMSD/S, where RMSD is the residual mean standard deviation of the measured points around a calibration curve with a slope of S). In spiked serum samples, the response was linear up to 300 ng mL(-1) of CK-MB. A surface plasmon resonance (SPR) system with simultaneous electrochemical detection (EC-SPR) aided the development of the sandwich immunoassay. Real-time monitoring of the SPR signal was used to optimize the capture antibody immobilization, CK-MB and detection antibody binding, as well as to minimize the nonspecific adsorption of serum proteins to the sensor surface. The detection antibody has been labeled with alkaline phosphatase (ALP) enzyme for sensitive electrochemical detection. ALP catalyzes the hydrolysis of ascorbic acid phosphate and generates ascorbic acid, which is measured chronoamperometrically. The electrochemical immunoassay for CK-MB was less sensitive to nonspecific adsorption related interferences, had a better detection limit, and required a lower volume of sample than the SPR method.
Collapse
Affiliation(s)
- Fernando Garay
- Department of Biomedical Engineering, The University of Memphis, Herff College of Engineering, 330 Engineering Technology Building, Memphis, TN 38152, USA
| | - Greggory Kisiel
- Department of Biomedical Engineering, The University of Memphis, Herff College of Engineering, 330 Engineering Technology Building, Memphis, TN 38152, USA
| | - Aiping Fang
- Department of Biomedical Engineering, The University of Memphis, Herff College of Engineering, 330 Engineering Technology Building, Memphis, TN 38152, USA
| | - Ernő Lindner
- Department of Biomedical Engineering, The University of Memphis, Herff College of Engineering, 330 Engineering Technology Building, Memphis, TN 38152, USA
| |
Collapse
|
10
|
A Systematic Review of Emergency Department Point-of-Care Cardiac Markers and Efficiency Measures. POINT OF CARE 2009. [DOI: 10.1097/poc.0b013e3181b316b9] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
11
|
Development and Introduction of Point-of-Care Testing in Mobile Critical Care Units for Improved Patient Safety in Rural Areas. POINT OF CARE 2009. [DOI: 10.1097/poc.0b013e3181b24315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
12
|
Dungchai W, Chailapakul O, Henry CS. Electrochemical Detection for Paper-Based Microfluidics. Anal Chem 2009; 81:5821-6. [DOI: 10.1021/ac9007573] [Citation(s) in RCA: 914] [Impact Index Per Article: 57.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Wijitar Dungchai
- Sensor Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand, Center of Excellence for Petroleum, Petrochemicals, and Advanced Materials, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand, and Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523-1872
| | - Orawon Chailapakul
- Sensor Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand, Center of Excellence for Petroleum, Petrochemicals, and Advanced Materials, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand, and Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523-1872
| | - Charles S. Henry
- Sensor Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand, Center of Excellence for Petroleum, Petrochemicals, and Advanced Materials, Chulalongkorn University, Patumwan, Bangkok, 10330, Thailand, and Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523-1872
| |
Collapse
|
13
|
Cardiac markers: a clear cause for point-of-care testing. Anal Bioanal Chem 2009; 393:1453-62. [PMID: 19148628 DOI: 10.1007/s00216-008-2573-z] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2008] [Revised: 11/04/2008] [Accepted: 12/08/2008] [Indexed: 01/21/2023]
Abstract
Point-of-care testing (POCT) in patients with ischemic heart disease is driven by the time-critical need for fast, specific, and accurate results to initiate therapy instantly. According to current guidelines, the results of the cardiac marker testing should be available to the physician within 30 min ("vein-to-brain" time) to initiate therapy within 60-90 min ("door-to-needle" time) after the patient has arrived at the emergency room or intensive care unit. This article reviews the current efforts to meet this goal (1) by implementing POCT of established biochemical markers such as cardiac troponins, creatine kinase MB, and myoglobin, in accelerated diagnosis and management workflow schemes, (2) by improving current POCT methods to obtain more accurate, more specific, and even faster tests through the integration of optical and electrochemical sensor technology, and (3) by identifying new markers for the very early and sensitive detection of myocardial ischemia and necrosis. Furthermore, the specific requirements for cardiac POCT in regard to analytical performance, comparability, and diagnostic sensitivity/specificity are discussed. For the future, the integration of new immunooptical and electrochemical chip technology might speed up diagnosis even further. However, every new development will have to meet the stringent method validation criteria set for corresponding central laboratory testing.
Collapse
|
14
|
Storrow AB, Zhou C, Gaddis G, Han JH, Miller K, Klubert D, Laidig A, Aronsky D. Decreasing lab turnaround time improves emergency department throughput and decreases emergency medical services diversion: a simulation model. Acad Emerg Med 2008; 15:1130-5. [PMID: 18638034 DOI: 10.1111/j.1553-2712.2008.00181.x] [Citation(s) in RCA: 85] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
BACKGROUND The effect of decreasing lab turnaround times on emergency department (ED) efficiency can be estimated through system-level simulation models and help identify important outcome measures to study prospectively. Furthermore, such models may suggest the advantage of bedside or point-of-care testing and how they might affect efficiency measures. OBJECTIVES The authors used a sophisticated simulation model in place at an adult urban ED with an annual census of 55,000 patient visits. The effect of decreasing turnaround times on emergency medical services (EMS) diversion, ED patient throughput, and total ED length of stay (LOS) was determined. METHODS Data were generated by using system dynamics analytic modeling and simulation approach on 90 separate days from December 2, 2007, through February 29, 2008. The model was a continuous simulation of ED flow, driven by real-time actual patient data, and had intrinsic error checking to assume reasonable goodness-of-fit. A return of complete laboratory results incrementally at 120, 100, 80, 60, 40, 20, and 10 minutes was compared. Diversion calculation assumed EMS closure when more than 10 patients were in the waiting room and 100% ED bed occupancy had been reached for longer than 30 minutes, as per local practice. LOS was generated from data insertion into the patient flow stream and calculation of time to specific predefined gates. The average accuracy of four separate measurement channels (waiting room volume, ED census, inpatient admit stream, and ED discharge stream), all across 24 hours, was measured by comparing the area under the simulated curve against the area under the measured curve. Each channel's accuracy was summed and averaged for an overall accuracy rating. RESULTS As lab turnaround time decreased from 120 to 10 minutes, the total number of diversion days (maximum 57 at 120 minutes, minimum 29 at 10 minutes), average diversion hours per day (10.8 hours vs. 6.0 hours), percentage of days with diversion (63% vs. 32%), and average ED LOS (2.77 hours vs. 2.17 hours) incrementally decreased, while average daily throughput (104 patients vs. 120 patients) increased. All runs were at least 85% accurate. CONCLUSIONS This simulation model suggests compelling improvement in ED efficiency with decreasing lab turnaround time. Outcomes such as time on EMS diversion, ED LOS, and ED throughput represent important but understudied areas that should be evaluated prospectively. EDs should consider processes that will improve turnaround time, such as point-of-care testing, to obtain these goals.
Collapse
Affiliation(s)
- Alan B Storrow
- Department of Emergency Medicine, Vanderbilt University, Nashville, TN, USA.
| | | | | | | | | | | | | | | |
Collapse
|
15
|
|
16
|
Emergency Department Multimarker Point-of-care Testing Reduces Time to Cardiac Marker Results Without Loss of Diagnostic Accuracy. POINT OF CARE 2006. [DOI: 10.1097/01.poc.0000232334.13428.7a] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
17
|
Kost GJ, Tran NK. Point-of-Care Testing and Cardiac Biomarkers: The Standard of Care and Vision for Chest Pain Centers. Cardiol Clin 2005; 23:467-90, vi. [PMID: 16278118 DOI: 10.1016/j.ccl.2005.08.005] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Point-of-care testing (POCT) is defined as testing at or near the site of patient care. POCTdecreases therapeutic turnaround time (TTAT), increases clinical efficiency, and improves medical and economic outcomes. TTAT represents the time from test ordering to patient treatment. POC technologies have become ubiquitous in the United States, and, therefore,so has the potential for speed, convenience, and satisfaction, strong advantages for physicians, nurses, and patients in chest pain centers. POCT is applied most beneficially through the collaborative teamwork of clinicians and laboratorians who use integrative strategies, performance maps, clinical algorithms, and care paths (critical pathways). For example, clinical investigators have shown that on-site integration of testing for cardiac injury markers (myoglobin, creatinine kinase myocardial band [CKMB],and cardiac troponin I [cTnI]) in accelerated diagnostic algorithms produces effective screening, less hospitalization, and substantial savings. Chest pain centers, which now total over 150 accredited in the United States, incorporate similar types of protocol-driven performance enhancements. This optimization allows chest pain centers to improve patient evaluation, treatment, survival, and discharge. This article focuses on cardiac biomarker POCT for chest pain centers and emergency medicine.
Collapse
Affiliation(s)
- Gerald J Kost
- Point-of-Care Testing Center for Teaching and Research, Department of Pathology and Laboratory Medicine,UCD Health System, School of Medicine, University of California, Davis, CA 95616, USA.
| | | |
Collapse
|
18
|
Cho JH, Paek EH, Cho IH, Paek SH. An Enzyme Immunoanalytical System Based on Sequential Cross-Flow Chromatography. Anal Chem 2005; 77:4091-7. [PMID: 15987114 DOI: 10.1021/ac048270d] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A new enzyme immunoanalytical concept that can be used for point-of-care testing has been investigated. Enzyme as a tracer requires a separate reaction step for signal generation, which follows the completion of immune complex formation with analyte (e.g., Hepatitis B surface antigen) in a sample. This has been a major factor limiting its utilization within the laboratory. We carried out such sequential processes employing chromatographic analysis, using two crosswise-arranged membrane pads in vertical and horizontal directions. The vertically arranged pads were the same as those in the usual format for pregnancy testing, for instance, with the exception of the use of horseradish peroxidase (HRP) as tracer. By placing the horizontally arranged pads on each lateral side of the signal generation pad in the vertical arrangement, they were employed to supply substrate to the enzyme present in the immune complexes. The substrate flow was initiated after the antigen-antibody bindings to produce a signal, which was typically a color change in proportion to the analyte concentration. Under optimal conditions, the use of HRP labeling increased the detection capability of the assay approximately 30 times compared to that of gold colloids. Potential advantages of using the concept investigated are (1) provision of a rapid and simple immunoassay, (2) satisfaction of a clinical need for highly sensitive determination of analyte, and (3) utilization of relatively inexpensive, portable quantitation means.
Collapse
Affiliation(s)
- Joung-Hwan Cho
- Graduate School of Biotechnology, BioDigit Laboratories Corp., and Program for Bio-Microsystem Technology, Korea University, 1, 5-ka, Anam-dong, Sungbuk-ku, Seoul 136-701, Korea
| | | | | | | |
Collapse
|
19
|
Point-of-Care Testing for Heart and Cardiovascular Diseases in Finnish Health Care Units. POINT OF CARE 2005. [DOI: 10.1097/01.poc.0000172442.67192.d3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
20
|
The Use of a Quantitative Point-of-Care System Greatly Reduces the Turnaround Time of Cardiac Marker Determination. POINT OF CARE 2004. [DOI: 10.1097/00134384-200412000-00003] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
21
|
|
22
|
Di Serio F, Antonelli G, Trerotoli P, Tampoia M, Matarrese A, Pansini N. Appropriateness of point-of-care testing (POCT) in an emergency department. Clin Chim Acta 2003; 333:185-9. [PMID: 12849903 DOI: 10.1016/s0009-8981(03)00184-0] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
BACKGROUND Acute coronary syndrome is a major cause of death, morbidity and access in emergency departments (ED). METHODS We evaluated a point-of-care testing (POCT) for the determinations of cardiac markers in an emergency department (ED), defining the clinical efficiency (management of patient with chest pain) and economic effectiveness (rationalization of preanalytical phase) related to data of Core Lab. RESULTS The results of analytical performances showed a good correlation (cTnI r(2)=0.89, myoglobin r(2)=0.84, CK-MB r(2)=0.9) between POCT and Core Lab and a significant decrease of the turn around time (TAT): difference of medians=-54 min, 95% CI from -48 to -60 min. CONCLUSIONS Our data confirmed that the accurate utilization of POCT in the ED assumes an effective triage of patient with chest pain and the improvement of preanalytical phase out of the laboratory (delivery of specimens) and within the laboratory reception, centrifugation. However, efficiency must be linked to methodological and quality control of the Core Lab, mainly through connectivity.
Collapse
Affiliation(s)
- Francesca Di Serio
- Patologia Clinica I, University-Hospital of Bari, Piazza Giulio Cesare N. 11, Bari, Italy.
| | | | | | | | | | | |
Collapse
|