1
|
Gandia P, Chaiben S, Fabre N, Concordet D. Vancomycin population pharmacokinetic models: Uncovering pharmacodynamic divergence amid clinicobiological resemblance. CPT Pharmacometrics Syst Pharmacol 2025; 14:142-151. [PMID: 39600109 PMCID: PMC11706421 DOI: 10.1002/psp4.13253] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 09/21/2024] [Accepted: 09/25/2024] [Indexed: 11/29/2024] Open
Abstract
Vancomycin is an antibiotic used for severe infections. To ensure microbiological efficacy, a ratio of AUC/MIC ≥400 is recommended. However, there is significant interindividual variability in its pharmacokinetic parameters, necessitating therapeutic drug monitoring to adjust dosing regimens and ensure efficacy while avoiding toxicity. Population pharmacokinetic (PopPK) models enable dose personalization, but the challenge lies in the choice of the model to use among the multitude of models in the literature. We compared 18 PopPK models created from populations with the same sociodemographic and clinicobiological characteristics. Simulations were performed for a 47 years old man, weighing 70 kg, with an albumin level of 35.5 g/L, a creatinine clearance of 100 mL/min, an eGFR of 106 mL/min/1.73 m2, and receiving an intravenous infusion of 1 g × 2/day of VCM over 1 h for 48 h. Simulations of time-concentration profiles revealed differences, leading us to determine the probability of achieving microbiological efficacy (AUC/MIC ≥ 400) with each model. Depending on some models, a dose of 1 g × 2/day is required to ensure microbiological efficacy in over 90% of the population, while with the same dose other models do not exceed 10% of the population. To ensure that 90% of the patients are correctly exposed, a dose of vancomycin ranging from 0.9 g × 2/day to 2.2 g × 2/day is necessary a priori depending on the chosen model. These differences raise an issue in choosing a model for performing therapeutic drug monitoring using a PopPK model with or without Bayesian approach. Thus, it is fundamental to evaluate the impact of these differences on both efficacy/toxicity.
Collapse
Affiliation(s)
- Peggy Gandia
- Pharmacokinetics and Toxicology Laboratory, Federative Institute of BiologyToulouse University HospitalToulouseFrance
- INTHERESUniversité de Toulouse, INRAE, ENVTToulouseFrance
| | - Sahira Chaiben
- INTHERESUniversité de Toulouse, INRAE, ENVTToulouseFrance
| | - Nicolas Fabre
- UMR 152 PharmaDevUniversity of Toulouse, IRD, UPSToulouseFrance
| | | |
Collapse
|
2
|
Lin Q, Nguyen T, Staffieri C, Van Schepdael A, Adams E. Development and Validation of Liquid Chromatographic Method for Fast Determination of Lincomycin, Polymyxin and Vancomycin in Preservation Solution for Transplants. Molecules 2024; 29:3166. [PMID: 38999118 PMCID: PMC11243236 DOI: 10.3390/molecules29133166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2024] [Revised: 06/25/2024] [Accepted: 06/27/2024] [Indexed: 07/14/2024] Open
Abstract
In this study, a liquid chromatographic method was developed for the fast determination of lincomycin, polymyxin and vancomycin in a preservation solution for transplants. A Kinetex EVO C18 (150 × 4.6 mm, 2.6 µm) column was utilized at 45 °C. Gradient elution was applied using a mixture of mobile phases A and B, both including 30 mM phosphate buffer at pH 2.0 and acetonitrile, at a ratio of 95:5 (v/v) for A and 50:50 (v/v) for B. A flow rate of 1.0 mL/min, an injection volume of 20 µL and UV detection at 210 nm were used. A degradation study treating the three antibiotics with 0.5 M hydrochloric acid, 0.5 M sodium hydroxide and 3% H2O2 indicated that the developed method was selective toward lincomycin, polymyxin, vancomycin and their degradation products. Other ingredients of the preservation solution, like those from the cell culture medium, did not interfere. The method was validated with good sensitivity, linearity, precision and accuracy. Furthermore, lincomycin, polymyxin and vancomycin were found to be stable in this preservation solution for 4 weeks when stored at -20 °C.
Collapse
Affiliation(s)
| | | | | | | | - Erwin Adams
- Department of Pharmaceutical and Pharmacological Sciences, Pharmaceutical Analysis, KU Leuven, Herestraat 49, O&N2, PB 923, 3000 Leuven, Belgium; (Q.L.); (T.N.); (C.S.); (A.V.S.)
| |
Collapse
|
3
|
Stajić A, Janković-Maksić J, Jančić-Stojanović B, Medenica M. AQbD-Oriented UHPLC/MS/MS Method Development for Glycopeptides Assessment in Pharmaceutical Forms. J Chromatogr Sci 2021; 59:650-658. [PMID: 33575745 DOI: 10.1093/chromsci/bmab004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 10/02/2020] [Indexed: 11/14/2022]
Abstract
Vancomycin and teicoplanin are glycopeptide antibacterials that inhibit the bacteria cell wall synthesis showing activity against gram-positive bacteria. Development of the sensitive method is of great importance for quality control of these drugs that are fermentation products. Modification of the fermentation conditions could cause the differences in the relative amount of the total substance or component, as it is the case with teicoplanin. The main objective of this study was development of the sensitive and effective ultra high performance liquid chromatography - tandem mass sprectrometry (UHPLC-MS/MS) method for simultaneous quantification of vancomycin, all six subcomponents of teicoplanin, and its pharmacopoeial impurity A in pharmaceutical forms. The scientific-based Quality by Design approach was implemented in the MS and UHPLC method development. Detection and quantification of analytes were carried out in positive electrospray ion mode by multiple reaction monitoring. Capillary voltage, cone voltage and collision energy were optimized by implementing experimental design methodology and optimal values for each fragment ion were obtained by performing experiments according to 'Rechtschaffen' design matrix. An ACQUITY CSH Phenyl-hexyl (2.1 × 50 mm, particle size 1.7 μm) column was chosen for the separation under the gradient elution mode with the mobile phase consisted of 0.1% formic acid in water (mobile phase A) and acetonitrile (mobile phase B). Optimal gradient elution parameters were achieved by applying 'Rechtschaffen' design too. Method operable design regions were constructed for investigated MS and chromatographic parameters. The method was fully validated, and its applicability was confirmed throughout the ability to follow the behavior of vancomycin and teicoplanin under stress conditions.
Collapse
Affiliation(s)
- A Stajić
- Department of Drug Analysis, Faculty of Pharmacy, University of Belgrade, 450 Vojvode Stepe, 11000 Belgrade, Serbia
| | - J Janković-Maksić
- Department of Drug Control and Examination, Sector for Pharmacy, Military Medical Academy, Crnotravska 17, 11000 Belgrade, Serbia
| | - B Jančić-Stojanović
- Department of Drug Analysis, Faculty of Pharmacy, University of Belgrade, 450 Vojvode Stepe, 11000 Belgrade, Serbia
| | - M Medenica
- Department of Physical Chemistry and Instrumental Methods, Faculty of Pharmacy, University of Belgrade, 450 Vojvode Stepe, 11000 Belgrade, Serbia
| |
Collapse
|
4
|
A systematic review on chromatography-based method validation for quantification of vancomycin in biological matrices. Bioanalysis 2020; 12:1767-1786. [PMID: 33275028 DOI: 10.4155/bio-2020-0230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
A fully validated bioanalytical methods are prerequisite for pharmacokinetic and bioequivalence studies as well as for therapeutic drug monitoring. Due to high pharmacokinetic variability and narrow therapeutic index, vancomycin requires reliable quantification methods for therapeutic drug monitoring. To identify published chromatographic based bioanalytical methods for vancomycin in current systematic review, PubMed and ScienceDirect databases were searched. The selected records were evaluated against the method validation criteria derived from international guidelines for critical assessment. The major deficiencies were identified in method validation parameters specifically for accuracy, precision and number of calibration and validation standards, which compromised the reliability of the validated bioanalytical methods. The systematic review enacts to adapt the recommended international guidelines for suggested validation parameters to make bioanalysis reliable.
Collapse
|
5
|
High-Performance Liquid Chromatography Enantioseparations Using Macrocyclic Glycopeptide-Based Chiral Stationary Phases: An Overview. Methods Mol Biol 2019; 1985:201-237. [PMID: 31069737 DOI: 10.1007/978-1-4939-9438-0_12] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Since their introduction by Daniel W. Armstrong in 1994, antibiotic-based chiral stationary phases have proven their applicability for the chiral resolution of various types of racemates. The unique structure of macrocyclic glycopeptides and their large variety of interactive sites (e.g., hydrophobic pockets, hydroxy, amino and carboxyl groups, halogen atoms, aromatic moieties) are the reasons for their wide-ranging selectivity. The commercially available Chirobiotic™ phases, which display complementary characteristics, are capable of separating a broad variety of enantiomeric compounds with good efficiency, good column loadability, high reproducibility, and long-term stability. These are the major reasons for the frequent use of macrocyclic antibiotic-based stationary phases in HPLC enantioseparations.This overview chapter provides a brief summary of general aspects of antibiotic-based chiral stationary phases including their preparation and their application to direct enantioseparations of various racemates focusing on the literature published since 2004.
Collapse
|
6
|
Brozmanová H, Kacířová I, Uřinovská R, Šištík P, Grundmann M. New liquid chromatography-tandem mass spectrometry method for routine TDM of vancomycin in patients with both normal and impaired renal functions and comparison with results of polarization fluoroimmunoassay in light of varying creatinine concentrations. Clin Chim Acta 2017; 469:136-143. [PMID: 28392327 DOI: 10.1016/j.cca.2017.04.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2017] [Revised: 04/05/2017] [Accepted: 04/05/2017] [Indexed: 10/19/2022]
Abstract
A new LC-MS/MS method with simple sample extraction and a relatively short period of vancomycin analysis for routine therapeutic drug monitoring was developed and validated. 50μL serum was precipitated using 20μL 33% trichloroacetic acid and 0.5mol/L NH4OH was added to increase pH before analysis. A RP BEH C18, 1.7μm, 2.1×50mm column maintained at 30°C and tobramycin as internal standard were used. Mass detection was performed in positive electrospray mode. The results obtained with LC-MS/MS method were correlated with an FPIA assay (Abbott AxSYM) using mouse monoclonal antibody. Subjects were divided into three groups according to creatinine levels (53.5±19.1, 150.2±48.4, 471.7±124.7μmol/L) and Passing-Bablok regression analysis and Bland-Altman analysis were used to compare vancomycin concentrations. The results of subjects with both normal and higher creatinine levels correlated very well and the linear regression model equations were near ideal (LC-MSVAN=0.947×AbbottVAN+0.192 and LC-MSVAN=0.973×AbbottVAN-0.411 respectively). Dialyzed patients with the highest creatinine levels showed about 14% greater vancomycin concentration with the FPIA assay (LC-MSVAN=0.866×AbbottVAN+2.127). This overestimation probably due to the presence of the metabolite CDP ought not to be of clinical relevance owing to the wide range of recommended vancomycin concentration.
Collapse
Affiliation(s)
- Hana Brozmanová
- Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic; Department of Clinical Pharmacology, Department of Laboratory Diagnostics, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic.
| | - Ivana Kacířová
- Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic; Department of Clinical Pharmacology, Department of Laboratory Diagnostics, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic
| | - Romana Uřinovská
- Department of Clinical Pharmacology, Department of Laboratory Diagnostics, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic
| | - Pavel Šištík
- Department of Clinical Pharmacology, Department of Laboratory Diagnostics, University Hospital Ostrava, 17. listopadu 1790, 708 52 Ostrava, Czech Republic
| | - Milan Grundmann
- Department of Clinical Pharmacology, Faculty of Medicine, University of Ostrava, Syllabova 19, 703 00 Ostrava, Czech Republic
| |
Collapse
|
7
|
Three structurally-related impurities in norvancomycin drug substance. J Antibiot (Tokyo) 2016; 70:158-165. [DOI: 10.1038/ja.2016.115] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2016] [Revised: 07/28/2016] [Accepted: 08/19/2016] [Indexed: 11/09/2022]
|
8
|
Usman M, Hempel G. Development and validation of an HPLC method for the determination of vancomycin in human plasma and its comparison with an immunoassay (PETINIA). SPRINGERPLUS 2016; 5:124. [PMID: 26933623 PMCID: PMC4759449 DOI: 10.1186/s40064-016-1778-4] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2015] [Accepted: 02/12/2016] [Indexed: 11/10/2022]
Abstract
Vancomycin (VAN) is among those antibiotics for which therapeutic drug monitoring is highly recommended. For this purpose a reliable method with small sample volume was required for quantification of VAN in human plasma. Therefore, a selective and sensitive method of high performance liquid chromatography was developed and validated. The separation was carried out isocratically by using a mobile phase NH4H2PO4 (50 mM, pH 2.2)–acetonitrile (88:12, v/v) at a flow rate of 0.36 mL/min on a nucleodur C18 column (125 mm × 4.6 mm, 5 µm) with UV detection at 205 nm. Sample preparation was done by deproteination of plasma with 70 % perchloric acid and a liquid/liquid extraction. Validation was performed according to the European Medicines Agency guideline. The method showed linearity over the range of 0.25–60 mg/L with a coefficient of determination r2 ≥ 0.999 and a lower limit of quantification of 0.25 mg/L. No interference was observed in blank plasma samples at the retention time of VAN. The percentage relative recovery and coefficient of variation (CV%) values for accuracy and precision were within the acceptable limits. Stability was proved at room temperature for 24 h, after repeated freeze and thaw cycles and storage at −20 °C for 3 months. A good correlation was observed (r = 0.947) by comparing with the results of an immunoassay (PETINIA, Siemens) in 289 samples. In conclusion the method proved simple, sensitive and cost effective for quantification of VAN in human plasma.
Collapse
Affiliation(s)
- Muhammad Usman
- Department of Pharmaceutical and Medicinal Chemistry - Clinical Pharmacy, University of Muenster, Corrensstrasse 48, 48149 Muenster, Germany
| | - Georg Hempel
- Department of Pharmaceutical and Medicinal Chemistry - Clinical Pharmacy, University of Muenster, Corrensstrasse 48, 48149 Muenster, Germany
| |
Collapse
|
9
|
Development of a Fourier transform infrared spectroscopy coupled to UV-Visible analysis technique for aminosides and glycopeptides quantitation in antibiotic locks. ANNALES PHARMACEUTIQUES FRANÇAISES 2014; 72:41-50. [PMID: 24438668 DOI: 10.1016/j.pharma.2013.10.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2013] [Revised: 10/23/2013] [Accepted: 10/26/2013] [Indexed: 11/21/2022]
Abstract
Antibiotic Lock technique maintains catheters' sterility in high-risk patients with long-term parenteral nutrition. In our institution, vancomycin, teicoplanin, amikacin and gentamicin locks are prepared in the pharmaceutical department. In order to insure patient safety and to comply to regulatory requirements, antibiotic locks are submitted to qualitative and quantitative assays prior to their release. The aim of this study was to develop an alternative quantitation technique for each of these 4 antibiotics, using a Fourier transform infrared (FTIR) coupled to UV-Visible spectroscopy and to compare results to HPLC or Immunochemistry assays. Prevalidation studies permitted to assess spectroscopic conditions used for antibiotic locks quantitation: FTIR/UV combinations were used for amikacin (1091-1115cm(-1) and 208-224nm), vancomycin (1222-1240cm(-1) and 276-280nm), and teicoplanin (1226-1230cm(-1) and 278-282nm). Gentamicin was quantified with FTIR only (1045-1169cm(-1) and 2715-2850cm(-1)) due to interferences in UV domain of parabens, preservatives present in the commercial brand used to prepare locks. For all AL, the method was linear (R(2)=0.996 to 0.999), accurate, repeatable (intraday RSD%: from 2.9 to 7.1% and inter-days RSD%: 2.9 to 5.1%) and precise. Compared to the reference methods, the FTIR/UV method appeared tightly correlated (Pearson factor: 97.4 to 99.9%) and did not show significant difference in recovery determinations. We developed a new simple reliable analysis technique for antibiotics quantitation in locks using an original association of FTIR and UV analysis, allowing a short time analysis to identify and quantify the studied antibiotics.
Collapse
|
10
|
Ilisz I, Aranyi A, Pataj Z, Péter A. Enantioseparations by high-performance liquid chromatography using macrocyclic glycopeptide-based chiral stationary phases: an overview. Methods Mol Biol 2013; 970:137-163. [PMID: 23283775 DOI: 10.1007/978-1-62703-263-6_8] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Since their introduction by Armstrong in 1994, macrocyclic antibiotic-based chiral stationary phases have proven their applicability for the chiral resolution of various types of racemates. The unique structure of macrocyclic glycopeptides and their large variety of interactive sites (e.g., hydrophobic pockets, hydroxyl, amino and carboxyl groups, halogen atoms, aromatic moieties, etc.) are the reason for their wide-ranging selectivity. The commercially available Chirobiotic™ phases, which display complementary characteristics, are capable of separating a broad variety of enantiomeric compounds with good efficiency, good column loadability, high reproducibility, and long-term stability. These are the major reasons for the use of macrocyclic antibiotic-based stationary phases in HPLC enantioseparations. This overview chapter provides a brief summary of general aspects of macrocyclic antibiotic-based chiral stationary phases including their preparation and their application to direct enantioseparations of various racemates focusing on the literature published since 2004.
Collapse
Affiliation(s)
- István Ilisz
- Department of Inorganic and Analytical Chemistry, University of Szeged, Szeged, Hungary
| | | | | | | |
Collapse
|
11
|
Ilisz I, Pataj Z, Aranyi A, Péter A. Macrocyclic Antibiotic Selectors in Direct HPLC Enantioseparations. SEPARATION AND PURIFICATION REVIEWS 2012. [DOI: 10.1080/15422119.2011.596253] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
12
|
Quality assessment of U.S. marketplace vancomycin for injection products using high-resolution liquid chromatography-mass spectrometry and potency assays. Antimicrob Agents Chemother 2012; 56:2824-30. [PMID: 22371900 DOI: 10.1128/aac.00164-12] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
In response to a published concern about the potency and quality of generic vancomycin products, the United States Food and Drug Administration investigated a small sampling of the vancomycin products available in North America with regard to purity, content, and potency. To facilitate identification of impurities, a new liquid chromatography method was developed using high-resolution mass spectrometry in addition to diode array detection to characterize impurities in several commercial products. Furthermore, a microbiological assay was utilized to link the analytical profiles with an in vitro potency. All products tested met the quality specifications outlined in the United States Pharmacopeia (USP) (vancomycin hydrochloride for injection monograph) for impurities and potency (USP, Vancomycin hydrochloride for injection. United States Pharmacopeia and National Formulary, vol USP 34-NF 29, 2011).
Collapse
|
13
|
Lu J, Wei Y, Rustum AM. A stability-indicating reversed-phase high performance liquid chromatography method for simultaneous assay of two corticosteroids and estimation of their related compounds in a pharmaceutical injectable formulation. J Chromatogr A 2010; 1217:6932-41. [DOI: 10.1016/j.chroma.2010.08.074] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2010] [Revised: 08/24/2010] [Accepted: 08/26/2010] [Indexed: 10/19/2022]
|
14
|
Van Arnum SD, Niemczyk HJ, Chang C. HPLC method validation studies on a specific assay for monomethoxypoly(ethylene glycol) succinimido carbonate (mPEG-SC). J Pharm Biomed Anal 2009; 50:138-43. [PMID: 19427154 DOI: 10.1016/j.jpba.2009.04.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2008] [Revised: 03/30/2009] [Accepted: 04/01/2009] [Indexed: 11/29/2022]
Abstract
An UV-HPLC method for the determination of the potency of mPEG-SC, 5 kDa (1) has been developed and validated. Validation acceptance criteria that is typical of small molecule method validation was successfully applied for this method. The method relies on the HPLC separation of mPEG-OH, 5 kDa (2) and a derivatized form of mPEG-SC, 5 kDa (1). 1-Naphthylmethylamine reacts with mPEG-SC, 5 kDa (1) to form a stable, strongly UV absorbing carbamate 3. When the eluent is analyzed by UV detection at 220 nm, the method was shown to be linear, precise and accurate. The limit of detection of the method was 0.1 microg.
Collapse
|
15
|
Ilisz I, Berkecz R, Péter A. Retention mechanism of high-performance liquid chromatographic enantioseparation on macrocyclic glycopeptide-based chiral stationary phases. J Chromatogr A 2008; 1216:1845-60. [PMID: 18762302 DOI: 10.1016/j.chroma.2008.08.041] [Citation(s) in RCA: 70] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2008] [Revised: 08/11/2008] [Accepted: 08/13/2008] [Indexed: 10/21/2022]
Abstract
The development of methods for the separation of enantiomers has attracted great interest in the past 20 years, since it became evident that the potential biological or pharmacological applications are mostly restricted to one of the enantiomers. In the past decade, macrocyclic antibiotics have proved to be an exceptionally useful class of chiral selectors for the separation of enantiomers of biological and pharmacological importance by means of high-performance liquid chromatography (HPLC), thin-layer chromatography and electrophoresis. The glycopeptides avoparcin, teicoplanin, ristocetin A and vancomycin have been extensively used as chiral selectors in the form of chiral bonded phases in HPLC, and HPLC stationary phases based on these glycopeptides have been commercialized. In fact, the macrocyclic glycopeptides are to some extent complementary to one another: where partial enantioresolution is obtained with one glycopeptide, there is a high probability that baseline or better separation can be obtained with another. This review sets out to characterize the physicochemical properties of these macrocyclic glycopeptide antibiotics and, through their application, endeavors to demonstrate the mechanism of separation on macrocyclic glycopeptides. The sequence of elution of the stereoisomers and the relation to the absolute configuration are also discussed.
Collapse
Affiliation(s)
- István Ilisz
- Department of Inorganic and Analytical Chemistry, University of Szeged, Dóm tér 7, H-6720 Szeged, Hungary
| | | | | |
Collapse
|
16
|
Júnior AR, Vila MMDC, Tubino M. Green Spectrophotometric Method for the Quantitative Analysis of Vancomycin in Pharmaceuticals and Comparison with HPLC. ANAL LETT 2008. [DOI: 10.1080/00032710801935103] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
17
|
Ilisz I, Berkecz R, Péter A. HPLC separation of amino acid enantiomers and small peptides on macrocyclic antibiotic-based chiral stationary phases: a review. J Sep Sci 2007; 29:1305-21. [PMID: 16894775 DOI: 10.1002/jssc.200600046] [Citation(s) in RCA: 133] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
The search for new and effective chiral selectors capable of separating a wide variety of enantiomeric compounds is an ongoing process. In the past decade, macrocyclic antibiotics have proved to be an exceptionally useful class of chiral selectors for the separation of enantiomers of biological and pharmacological importance by means of HPLC, TLC and electrophoresis. More chiral analytes have been resolved through the use of glycopeptides than with all the other macrocyclic antibiotics combined (ansamycins, thiostrepton, aminoglycosides, etc.). The glycopeptides avoparcin, teicoplanin, ristocetin A and vancomycin have been extensively used as chiral selectors in the form of chiral bonded phases in HPLC, and HPLC stationary phases based on these glycopeptides have been commercialized. Teicoplanin, vancomycin, their analogs and ristocetin A seem to be the most useful glycopeptide HPLC bonded phases for the enantioseparation of proteins and unusal native and derivatized amino acids. In fact, the macrocyclic glycopeptides are to some extent complementary to one another: where partial enantioresolution is obtained with one glycopeptide, there is a high probability that baseline or better separation can be obtained with another. This review sets out to characterize the physicochemical properties of these antibiotics and their application in the enantioseparations of amino acids. The mechanism of separation, the sequence of elution of the stereoisomers and the relation to the absolute configuration are also discussed.
Collapse
Affiliation(s)
- István Ilisz
- Department of Inorganic and Analytical Chemistry, University of Szeged, Hungary
| | | | | |
Collapse
|
18
|
Indirect spectrophotometric determination of gentamicin and vancomycin antibiotics based on their oxidation by potassium permanganate. OPEN CHEM 2006. [DOI: 10.2478/s11532-006-0035-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
AbstractFour simple, accurate, sensitive and economical procedures (A–D) for the estimation of gentamicin sulphate and vancomycin hydrochloride, both in pure form and in pharmaceutical formulations have been developed. The methods are based on the oxidation of the studied drugs by a known excess of potassium permanganate in sulphuric acid medium and subsequent determination of unreacted oxidant by reacting it with amaranth dye (method A), acid orange II (method B), indigocarmine (method C) and methylene blue (method D), in the same acid medium at a suitable λmax=521, 485, 610 and 664 nm, respectively. The reacted oxidant corresponds to the drug content. Regression analysis of Beer-Lambert plots showed good correlations in the concentration ranges 4–8, 3–8, 4–9 and 5–9 µg ml−1 with gentamicin and 4–8, 1.5–4, 1.5–4 and 3.5–5.5 µg ml−1 with vancomycin for methods A, B, C, and D, respectively. The molar absorptivity, sandell sensitivity, detection and quantification limits were calculated. The stoichiometric ratios for the cited drugs were studied. The optimum reaction conditions and other analytical parameters were evaluated. The influence of the substance commonly employed as excipients with these drugs were studied. The proposed methods were applied to the determination of these drugs in pharmaceutical formulations. The results have demonstrated that the methods are equally accurate and reproducible as the official methods.
Collapse
|
19
|
Torres-Lapasió JR, García-Alvarez-Coque MC. Levels in the interpretive optimisation of selectivity in high-performance liquid chromatography: A magical mystery tour. J Chromatogr A 2006; 1120:308-21. [PMID: 16563407 DOI: 10.1016/j.chroma.2006.03.008] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2005] [Revised: 03/01/2006] [Accepted: 03/02/2006] [Indexed: 11/26/2022]
Abstract
Interpretive approaches for selectivity optimisation, which are those supported by retention models, are able to exploit efficiently the capabilities of the chromatographic system. The resolution of a mixture is usually faced in a first trial by looking for a unique experimental condition, able to resolve all compounds in the sample. If this is not possible, the problem can be outlined with less ambitious aims, focusing on only some compounds. In an extreme case, a single analyte can be individually optimised. Current strategies that give answer to the different goals pursued in the analysis, which are classified as total, partial and specific, are reviewed. Optimisation oriented to deconvolution, useful in case of partial coelution, and robust measurements of resolution, are also outlined. The steps recognised in any chromatographic optimisation procedure, and some fundamentals and tools used in optimisation approaches for isocratic and gradient elution are commented to explain different strategies. Examples of increasing complexity are supplied to explain the problematic arose, and the convenience in applying a certain methodology. Details on the mathematical treatment for each particular optimisation strategy are also given.
Collapse
Affiliation(s)
- J R Torres-Lapasió
- Departament de Química Analítica, Facultat de Química, Universitat de València, c/Dr. Moliner 50, 46100 Burjassot, Spain
| | | |
Collapse
|
20
|
Diana J, Visky D, Hoogmartens J, Van Schepdael A, Adams E. Investigation of vancomycin and related substances by liquid chromatography/ion trap mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:685-93. [PMID: 16447148 DOI: 10.1002/rcm.2364] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Liquid chromatography (LC) methods compatible with mass spectrometry (MS) that are suitable for impurity profiling of vancomycin mixtures have not been described in the literature. The mobile phases of the existing methods contain non-volatile additives and/or solvents that give problems in combination with MS. In this paper, a reversed-phase LC/tandem mass spectrometry method is described for the investigation of vancomycin and related substances. The LC method uses a Zorbax Extend C18 column (250 x 4.6 mm i.d.), 5 microm, and a mobile phase consisting of methanol, water and ammonium acetate solution (pH 9.0). This method allows us to separate vancomycin and its impurities. Mass spectral data are acquired on an LCQ ion trap mass spectrometer equipped with an electrospray interface operated in the positive and negative ion modes. The LCQ is ideally suited for identification of impurities and related substances because it provides on-line LC/MSn capability, which allows efficient identification without time-consuming isolation and purification procedures. Using this method, the fragmentation of vancomycin and known derivatives was studied and the structures of six substances occurring in commercial samples were elucidated.
Collapse
Affiliation(s)
- J Diana
- Katholieke Universiteit Leuven, Faculteit Farmaceutische Wetenschappen, Laboratorium voor Farmaceutische Chemie en Analyse van Geneesmiddelen, O & N2, PB 923, Herestraat 49, B-3000 Leuven, Belgium
| | | | | | | | | |
Collapse
|
21
|
Affiliation(s)
- R K Gilpin
- Brehm Research Laboratories, College of Science and Mathematics, Wright State University, Dayton, Ohio 45435, USA
| | | |
Collapse
|