1
|
Dolinskaia G, Blumberg LM. Dimensionless plate height is unsuitable for comparing chromatographic columns. J Chromatogr A 2023; 1710:464406. [PMID: 37776824 DOI: 10.1016/j.chroma.2023.464406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/05/2023] [Accepted: 09/19/2023] [Indexed: 10/02/2023]
Abstract
Dimensionless plate height (h) is differently defined for the columns with different type of internal filling (internal support structure). It is h = H/d for open columns (d is the internal diameter), h = H/dp for packed columns (dp is the particle size), h = H/ddom (ddom is the domain size) for columns with other filling (e.g., monolithic, pillar array). The plate height (H) and the column kinetic performance in general depend on the flow channels through the column filling - on their cross-sectional dimensions (dchan), shape, and wall porosity. Other than through their effect on the flow channels, the dimensions of skeleton of the filling and the ddom do not affect H. Parameters d, dp and ddom cannot be found from external measurements of a column as a "black box" separation device and, therefore, are unmeasurable subjective metrics, and, therefore, so is h. Moreover, in some fillings (e.g., monolithic, pillar array) ddom can be chosen independently of dchan. By increasing ddom without changing dchan, one can make h as small as desired with no effect on H and on the column kinetic performance in general. This implies that h does not represent column performance and cannot be used for comparing differently structured column. In this report, previously introduced measurable (objective) performance metrics - the kinetic performance factor (q) and the quality factor (qmax) are described and evaluated. The latter is suitable for comparing differently structured columns. A column practically achievable performance depends not only on qmax, but on the largest pressure that a column can tolerate, the narrowest flow channels that can be manufactured and other practical factors. Practically achievable performance of several column types is compared in this report.
Collapse
|
2
|
Chocholouš P, Matoušová K, Šatínský D, Krčmová LK, Sklenářová H. Longevity and other practical benefits of monolithic silica columns in the analysis of samples with complex matrices. J Sep Sci 2023; 46:e2300448. [PMID: 37582639 DOI: 10.1002/jssc.202300448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 07/31/2023] [Accepted: 08/01/2023] [Indexed: 08/17/2023]
Abstract
At the turn of the millennium, the monolithic columns invoked new chances in HPLC. Even more than their organic polymer-based siblings, the inorganic silica-based monoliths targeted the territory of classical fully porous particle-packed columns, promising many benefits. Based on the number of published articles, the monoliths attracted academics just in the first few years after their introduction to the market. Lately, as superficially porous particles and sub-2-micron fully porous particles dominated the market, they stayed in the focus of routine laboratories and those who really appreciated the high porosity of the monolithic bed. The monoliths' practical benefits cannot be easily traced in the literature when they gradually lose academics' interest. Nevertheless, after more than 20 years of our experience, we still favor silica monoliths for their low back pressure and longevity when analyzing samples of clinical, pharmaceutical, and environmental origin. At the same time, the high permeability of monoliths enabled the birth of sequential injection chromatography, the medium-pressure separation technique based on the flexible flow manifold. This minireview aims to check, discuss, and summarize the practical aspects of monolithic silica columns in HPLC and medium-pressure sequential injection chromatography (SIC) that may not be visible at first sight but are evident retrospectively.
Collapse
Affiliation(s)
- Petr Chocholouš
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Hradec Králové, Czech Republic
| | - Kateřina Matoušová
- Department of Clinical Biochemistry and Diagnostics, University Hospital, Hradec Králové, Czech Republic
| | - Dalibor Šatínský
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Hradec Králové, Czech Republic
| | - Lenka Kujovská Krčmová
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Hradec Králové, Czech Republic
- Department of Clinical Biochemistry and Diagnostics, University Hospital, Hradec Králové, Czech Republic
| | - Hana Sklenářová
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Hradec Králové, Czech Republic
| |
Collapse
|
3
|
Hefnawy M, El-Gendy M, Al-Salem H, Marenga H, El-Azab A, Abdel-Aziz A, Gamal AE, Alanazi M, Obaidullah A, Al-Hossaini A, Hefnawy A. Trends in monoliths: Packings, stationary phases and nanoparticles. J Chromatogr A 2023; 1691:463819. [PMID: 36724721 DOI: 10.1016/j.chroma.2023.463819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 01/18/2023] [Accepted: 01/20/2023] [Indexed: 01/26/2023]
Abstract
Monoliths media are gaining interest as excellent substitutes to conventional particle-packed columns. Monolithic columns show higher permeability and lower flow resistance than conventional liquid chromatography columns, providing high-throughput performance, resolution and separation in short run times. Monolithic columns with longer length, smaller inner diameter and specific selectivity to peptides or enantiomers have been played important role in hyphenated system. Monolithic stationary phases possess great efficiency, resolution, selectivity and sensitivity in the separation of complex biological samples, such as the complex mixtures of peptides for proteome analysis. The development of monolithic stationary phases has opened the new avenue in chromatographic separation science and is in turn playing much more important roles in the wide application area. Monolithic stationary phases have been widely used in fast and high efficiency one- and multi-dimensional separation systems, miniaturized devices, and hyphenated system coupled with mass spectrometers. The developing technology for preparation of monolithic stationary phases is revolutionizing the column technology for the separation of complex biological samples. These techniques using porous monoliths offer several advantages, including miniaturization and on-line coupling with analytical instruments. Additionally, monoliths are ideal support media for imprinting template-specific sites, resulting in the so-called molecularly-imprinted monoliths, with ultra-high selectivity. In this review, the origin of the concept, the differences between their characteristics and those of traditional packings, their advantages and drawbacks, theory of separations, the methods for the monoliths preparation of different forms, nanoparticle monoliths and metal-organic framework are discussed. Two application areas of monolithic metal-organic framework and nanoparticle monoliths are provided. The review article discusses the results reported in a total of 218 references. Other older references were included to illustrate the historical development of monoliths, both in preparation and types, as well as separation mechanism.
Collapse
Affiliation(s)
- Mohamed Hefnawy
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia; Department of Analytical Chemistry, Faculty of Pharmacy, Mansoura University, Mansoura 35516, Egypt.
| | - Manal El-Gendy
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Huda Al-Salem
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Hanin Marenga
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Adel El-Azab
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Alaa Abdel-Aziz
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Ali El Gamal
- Department of Pharmacognosy and Medicinal, Aromatic & Poisonous Plant Research Center (MAPPRC), College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Mohammed Alanazi
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Ahmad Obaidullah
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Abdullah Al-Hossaini
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P. O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Abdullah Hefnawy
- Faculty of Medicine, Mansoura Manchester Medical Program, Mansoura University, Mansoura, Egypt
| |
Collapse
|
4
|
Lenčo J, Jadeja S, Naplekov DK, Krokhin OV, Khalikova MA, Chocholouš P, Urban J, Broeckhoven K, Nováková L, Švec F. Reversed-Phase Liquid Chromatography of Peptides for Bottom-Up Proteomics: A Tutorial. J Proteome Res 2022; 21:2846-2892. [PMID: 36355445 DOI: 10.1021/acs.jproteome.2c00407] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The performance of the current bottom-up liquid chromatography hyphenated with mass spectrometry (LC-MS) analyses has undoubtedly been fueled by spectacular progress in mass spectrometry. It is thus not surprising that the MS instrument attracts the most attention during LC-MS method development, whereas optimizing conditions for peptide separation using reversed-phase liquid chromatography (RPLC) remains somewhat in its shadow. Consequently, the wisdom of the fundaments of chromatography is slowly vanishing from some laboratories. However, the full potential of advanced MS instruments cannot be achieved without highly efficient RPLC. This is impossible to attain without understanding fundamental processes in the chromatographic system and the properties of peptides important for their chromatographic behavior. We wrote this tutorial intending to give practitioners an overview of critical aspects of peptide separation using RPLC to facilitate setting the LC parameters so that they can leverage the full capabilities of their MS instruments. After briefly introducing the gradient separation of peptides, we discuss their properties that affect the quality of LC-MS chromatograms the most. Next, we address the in-column and extra-column broadening. The last section is devoted to key parameters of LC-MS methods. We also extracted trends in practice from recent bottom-up proteomics studies and correlated them with the current knowledge on peptide RPLC separation.
Collapse
Affiliation(s)
- Juraj Lenčo
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Siddharth Jadeja
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Denis K Naplekov
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Oleg V Krokhin
- Department of Internal Medicine, Manitoba Centre for Proteomics and Systems Biology, University of Manitoba, 799 JBRC, 715 McDermot Avenue, WinnipegR3E 3P4, Manitoba, Canada
| | - Maria A Khalikova
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Petr Chocholouš
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - Jiří Urban
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00Brno, Czech Republic
| | - Ken Broeckhoven
- Department of Chemical Engineering (CHIS), Faculty of Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050Brussel, Belgium
| | - Lucie Nováková
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| | - František Švec
- Department of Analytical Chemistry, Faculty of Pharmacy in Hradec Králové, Charles University, Heyrovského 1203/8, 500 05Hradec Králové, Czech Republic
| |
Collapse
|
5
|
KOBAYASHI H, WADA H, KUBO T, OTSUKA K. Development and Evaluation of a Silica-monolithic Micro-trap Column for LC/MS Analysis of Intact Proteins. BUNSEKI KAGAKU 2022. [DOI: 10.2116/bunsekikagaku.71.341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
| | | | - Takuya KUBO
- Graduate School of Engineering, Kyoto University
| | - Koji OTSUKA
- Graduate School of Engineering, Kyoto University
| |
Collapse
|
6
|
Podgornik A. Characterization of a convection-based support microstructure through a flow resistance parameter. J Sep Sci 2022; 45:1984-1996. [PMID: 35218615 PMCID: PMC10138761 DOI: 10.1002/jssc.202100955] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 02/04/2022] [Accepted: 02/06/2022] [Indexed: 11/11/2022]
Abstract
Modern convection-based supports differ substantially in pore size, porosity, and microstructure topology. Due to such variability, it is challenging to evaluate the contribution of a particular microstructure topology on flow resistance. We demonstrated that the flow resistance parameter (ϕ) introduced decades ago can be used as a criterion to evaluate the effect of microstructure topology on a pressure drop when the pore size is used as a characteristic support dimension. Furthermore, the ϕ value of simple cubic packing was calculated over the entire range of open porosity and compared to the ϕ values determined for pressure drop models derived for particular convection-based supports and experimental values of various convection-based supports from the literature. It was shown that different convection-based supports become clustered into distinct groups when plotted according to their ϕ and open porosity values, allowing their discrimination. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Aleš Podgornik
- University of Ljubljana, Faculty of Chemistry and Chemical Technology, Večna pot 113, Ljubljana, Slovenia.,COBIK, Mirce 21, 5270 Ajdovščina, Slovenia
| |
Collapse
|
7
|
Přibyl M, Izák P, Slouka Z. A mathematical model of a lateral electrochromatography device for continuous chiral separation. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2021.120033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
8
|
Shakya AK. Functionalized cryogel monoliths for fast and selective separation of nucleic acids directly from crude lysate. Biomed Chromatogr 2022; 36:e5333. [DOI: 10.1002/bmc.5333] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/10/2021] [Accepted: 01/03/2022] [Indexed: 11/10/2022]
|
9
|
Foster SW, Wright N, Grinias JP, Blumberg LM. Measurement of optimal flow rate in gradient elution liquid chromatography. J Chromatogr A 2021; 1659:462645. [PMID: 34731749 DOI: 10.1016/j.chroma.2021.462645] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 11/30/2022]
Abstract
Method development in gradient LC relies upon the selection of a solvent time program and a mobile phase flow rate. The flow rate, optimal for gradient separation cannot be inherently predicted by the isocratic value optimal for a given analyte, and rather should be identified independently to ensure the highest separation performance of gradient analysis. The optimal flow rate (Fopt) is defined herein as the solvent volumetric flow rate (F) maximizing the separation (Δs) of a predetermined peak-pair or the separation capacity (sc) of the entire LC analysis. The theoretical background and the experimental technique of measurement of Fopt in gradient elution analysis were considered and experimentally demonstrated. The technique of measuring Fopt is based on translatable changes of F where the product FtG (tG is the gradient time) was the same for all values of F. The Fopt was found as F corresponding to the maximum in Δs or in sc.
Collapse
Affiliation(s)
- Samuel W Foster
- Department of Chemistry & Biochemistry, Rowan University, 201 Mullica Hill Rd, Glassboro, NJ 08028, United States of America
| | - Nicholas Wright
- Department of Chemistry & Biochemistry, Rowan University, 201 Mullica Hill Rd, Glassboro, NJ 08028, United States of America
| | - James P Grinias
- Department of Chemistry & Biochemistry, Rowan University, 201 Mullica Hill Rd, Glassboro, NJ 08028, United States of America
| | - Leonid M Blumberg
- Advachrom, P.O. Box 1243, Wilmington, DE 19801, United States of America.
| |
Collapse
|
10
|
Blumberg LM. Column length is a structure-independent measure of solvent consumption in liquid chromatography. J Chromatogr A 2021; 1662:462727. [PMID: 34902720 DOI: 10.1016/j.chroma.2021.462727] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 11/16/2022]
Abstract
Column length (L) is a measure of solvent consumption in LC analysis. In its latter role, L is the specific solvent consumption - the void time (tM) solvent consumption per unit of the column flow-area (AF) which is the cross-sectional area of the column open space (external and internal pores). In tanal-long LC analysis (isocratic or gradient), the solvent consumption (VS) is VS = AFLtanal /tM regardless of flow rate (F) as long as all changes in column dimensions and operational parameters are translatable (in gradient analysis, the ratio of the gradient time (tG) to tM remains fixed).
Collapse
|
11
|
Ota S, Yui Y, Sato T, Yoshimoto N, Yamamoto S. Rapid Purification of Immunoglobulin G Using a Protein A-immobilized Monolithic Spin Column with Hydrophilic Polymers. ANAL SCI 2021; 37:985-990. [PMID: 33281136 DOI: 10.2116/analsci.20p378] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2020] [Accepted: 11/29/2020] [Indexed: 08/09/2023]
Abstract
A rapid purification method was developed for antibody production in Chinese hamster ovary (CHO) cells using a Protein A-immobilized monolithic silica spin column with hydrophilic polymers. Monolithic silica modified with copolymers of 2-hydroxyethylmethacrylate (HEMA) and glycidyl methacrylate (GMA) showed lower non-specific protein absorption than that modified with a silane reagent. The epoxy group of GMA was converted to an amino group, and Protein A was modified by the coupling reagent. The amount of immobilized Protein A was controlled by changing the ratio of GMA to HEMA and the mesopore size of monolith. A modified monolith disk was fixed to a spin column for rapid antibody purification. The linear curves (for the antibody concentrations over 10 - 300 μg/mL) had a correlation coefficient of >0.999. Our column had various analytical advantages over previously reported columns, including a shorter preparation time (<10 min) and smaller sample volumes for purification with Protein A-immobilized agarose.
Collapse
Affiliation(s)
- Shigenori Ota
- Bio-Process Engineering Laboratory, Graduate School of Yamaguchi University Biomedical Engineering Center (YUBEC), 2-16-1 Tokiwadai, Ube, 755-8611, Japan.
| | - Yuko Yui
- GL Sciences Inc., 237-2 Sayamagahara, Iruma, Saitama, 358-0032, Japan
| | - Tsutomu Sato
- GL Sciences Inc., 237-2 Sayamagahara, Iruma, Saitama, 358-0032, Japan
| | - Noriko Yoshimoto
- Bio-Process Engineering Laboratory, Graduate School of Yamaguchi University Biomedical Engineering Center (YUBEC), 2-16-1 Tokiwadai, Ube, 755-8611, Japan
| | - Shuichi Yamamoto
- Bio-Process Engineering Laboratory, Graduate School of Yamaguchi University Biomedical Engineering Center (YUBEC), 2-16-1 Tokiwadai, Ube, 755-8611, Japan
| |
Collapse
|
12
|
Hara T, Baron GV, Hata K, Izumi Y, Bamba T, Desmet G. Performance of functionalized monolithic silica capillary columns with different mesopore sizes using radical polymerization of octadecyl methacrylate. J Chromatogr A 2021; 1651:462282. [PMID: 34144397 DOI: 10.1016/j.chroma.2021.462282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 04/26/2021] [Accepted: 05/18/2021] [Indexed: 11/29/2022]
Abstract
We report on the possibility to enhance the phase ratio and retention factor in silica monoliths. According to pioneering work done by Núñez et al. [1], this enhancement is pursued by applying a stationary phase layer via radical polymerization with octadecyl methacrylate (ODM) as an alternative to the customary octadecylsilylation (C18-derivatization). The difference in band broadening, retention factor and separation selectivity between both approaches was compared. Different hydrothermal treatment temperatures for the column preparation were applied to produce monolithic silica structures with three different mesopore sizes (resp. 10, 13, and 16 nm, as determined by argon physisorption) while maintaining similar domain size (sum of through-pore and skeleton size). It has been found that the columns with the poly(octadecyl methacrylate)-phase (ODM columns) provided a 60 to 80% higher retention factor in methanol-water mixture compared to the octadecylsilylated (ODS) columns produced by starting from similar silica backbone structures. In acetonitrile-water mixture, the enhancement is smaller (15 to 30% times higher), yet significant. By adjusting the fabrication conditions (for both the preparation of the monolithic backbones and the surface functionalization), the achieved retention factors (up k = 4.89 for pentylbenzene in 80:20% (v/v) methanol/water) are obviously higher than obtained in the pioneering study on ODM monoliths of Núñez et al. [1], and column clogging could be completely avoided. In addition, also separation efficiencies were significantly higher than shown in Ref. [1], with plate heights as low as 5.8 μm. These plate heights are however inferior to those observed on the ODS-modified sister columns. The difference can be explained by the slower intra-skeleton diffusion displayed by the ODM-modified columns, in turn caused by the larger obstruction to diffusion originating from the thicker stationary phase layer.
Collapse
Affiliation(s)
- Takeshi Hara
- Division of Metabolomics, Medical Institute of Bioregulation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan; GL Sciences Inc., 237-2 Sayamagahara, Iruma, Saitama 358-0032, Japan
| | - Gino V Baron
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, Brussels B-1050, Belgium
| | - Kosuke Hata
- Division of Metabolomics, Medical Institute of Bioregulation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Yoshihiro Izumi
- Division of Metabolomics, Medical Institute of Bioregulation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Takeshi Bamba
- Division of Metabolomics, Medical Institute of Bioregulation, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan.
| | - Gert Desmet
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, Brussels B-1050, Belgium.
| |
Collapse
|
13
|
Blumberg LM. Basic Structure-Independent Equations of Kinetic Performance of Columns in Liquid Chromatography. Anal Chem 2021; 93:5309-5316. [PMID: 33734674 DOI: 10.1021/acs.analchem.1c00514] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The lowest dimensionless plate height (hmin) of the liquid chromatography (LC) column is a subjective metric that cannot be found from measurements of parameters of a column as a separation device and is not suitable for comparison of kinetic performance of differently structured columns. In some cases (monolithic, pillar-array columns), there is no correlation between hmin (as it is currently understood) and the column performance. The same is true for the flow resistance parameter (ϕ). Recently introduced measurable effective diameter and structural quality factor (qmax) of a column are objective replacements for ϕ and hmin. Metric qmax, the maximum of the flow-dependent kinetic performance factor (q), is suitable for comparison of differently structured columns. Structure-independent basic equations binding kinetic performance of LC column with its q and other parameters and operational conditions were developed. It has been shown that previously known and new equations of a column kinetic performance can be derived from the basic ones. An example of using the equations for solving a known practical problem of column selection is provided.
Collapse
|
14
|
Advancements in the preparation and application of monolithic silica columns for efficient separation in liquid chromatography. Talanta 2021; 224:121777. [PMID: 33379011 DOI: 10.1016/j.talanta.2020.121777] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 10/11/2020] [Accepted: 10/12/2020] [Indexed: 01/23/2023]
Abstract
Fast and efficient separation remains a big challenge in high performance liquid chromatography (HPLC). The need for higher efficiency and resolution in separation is constantly in demand. To achieve that, columns developed are rapidly moving towards having smaller particle sizes and internal diameters (i.d.). However, these parameters will lead to high back-pressure in the system and will burden the pumps of the HPLC instrument. To address this limitation, monolithic columns, especially silica-based monolithic columns have been introduced. These columns are being widely investigated for fast and efficient separation of a wide range of molecules. The present article describes the current methods developed to enhance the column efficiency of particle packed columns and how silica monolithic columns can act as an alternative in overcoming the low permeability of particle packed columns. The fundamental processes behind the fabrication of the monolith including the starting materials and the silica sol-gel process will be discussed. Different monolith derivatization and end-capping processes will be further elaborated and followed by highlights of the performance such monolithic columns in key applications in different fields with various types of matrices.
Collapse
|
15
|
Kube SA, Turke K, Ellinghaus R, Wallacher D, Thommes M, Smarsly BM. Pore Size Gradient Effect in Monolithic Silica Mesopore Networks Revealed by In-Situ SAXS Physisorption. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:11996-12009. [PMID: 32936653 DOI: 10.1021/acs.langmuir.0c02183] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In disordered mesopore networks, the size distribution and connection between adjacent pores control desorption. How network characteristics can be extracted from corresponding physisorption isotherms is still a matter of research. To elucidate this, we study krypton physisorption (117.8 K) in the mesopore networks of "Nakanishi"-type monolithic silica. Combining physisorption in scanning acquisition mode with synchrotron-based in-situ SAXS provides complementary information on pore-filling states. These data reveal a mean pore size gradient in which pores grow smaller towards the material's network center. This structural motif cannot be derived through conventional isotherm analysis, but it is clearly exposed through scanning desorption curves which do not quite converge but merge individually with the main desorption isotherm before the lower hysteresis closing point. Hence, our findings provide the basis to build advanced models for analyzing scanning isotherms and extracting network characteristics through new descriptors, such as pore size and connectivity distributions as a function of the distance from the network center.
Collapse
Affiliation(s)
- Sebastian A Kube
- Department of Mechanical Engineering and Materials Science, Yale University, 15 Prospect Street, New Haven, Connecticut 06511, United States
| | | | | | - Dirk Wallacher
- Helmholtz Center Berlin for Materials and Energy, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
| | - Matthias Thommes
- Institute of Separation Science and Technology, Department of Chemical and Bioengineering, University of Erlangen-Nuremberg, Egerlandstrasse 3, 91058 Erlangen, Germany
| | | |
Collapse
|
16
|
Blumberg LM. Practical limits to column performance in liquid chromatography - Optimal operations. J Chromatogr A 2020; 1629:461482. [PMID: 32827904 DOI: 10.1016/j.chroma.2020.461482] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2020] [Revised: 08/11/2020] [Accepted: 08/12/2020] [Indexed: 12/13/2022]
Abstract
Columns of different structures have different potential kinetic performance - the trade-off between separation, time, and pressure. However, the full potential of a structure cannot always be realized in practically existing columns. Each combination of column efficiency, time, and pressure requires certain cross-sectional dimensions of the column flow-through channels. However, there are limits to the narrowest flow-through channels that can be manufactured with current technology. As a result, columns of some structures cannot be optimized for providing the required efficiency in the shortest time. Additionally, the full potential of its structure can be realized only if a column can operate at the highest pressure available from liquid chromatography (LC) equipment, has sufficient loadability, and satisfies other practical requirements. Equations tailored for a systematic approach to evaluation of factors affecting performance of optimized LC columns (effects of column structure, column dimensions, operational conditions, etc.) were developed. Parameters quantifying the performance of a specific column at and below its largest acceptable pressure were identified. New objective performance parameters of columns and their structures were introduced. Among them are the apparent structural quality factor accounting for the effect of insufficiently high pressure acceptable for the column, the dimensionless plate duration - the parameter of a column structure affecting its performance when the pressure is not limited, - and others. Applying the theory developed herein to published data, the performance of several differently structured columns is evaluated, and the factors affecting their comparative performance are discussed. In the final count, not the quality of a column structure, but practical factors such as the narrowest manufacturable flow-through channels can dominate the choice of the kinetically most suitable column for a practical LC analysis.
Collapse
|
17
|
Staniak M, Wójciak M, Sowa I, Tyszczuk-Rotko K, Strzemski M, Dresler S, Myśliński W. Silica-Based Monolithic Columns as a Tool in HPLC-An Overview of Application in Analysis of Active Compounds in Biological Samples. Molecules 2020; 25:molecules25143149. [PMID: 32660127 PMCID: PMC7397265 DOI: 10.3390/molecules25143149] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 07/02/2020] [Accepted: 07/06/2020] [Indexed: 01/08/2023] Open
Abstract
Monolithic fillings used in chromatography are of great interest among scientists since the first reports of their synthesis and use were published. In the 20 years since silica-based monolithic columns were introduced into the commercial market, numerous papers describing their chromatographical properties and utility in various branches of industry and scientific investigations were presented. This review is focused on possible applications of commercially available silica-based HPLC monolithic columns in the analysis of biological samples.
Collapse
Affiliation(s)
- Michał Staniak
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
- Correspondence: (M.S.); (M.W.)
| | - Magdalena Wójciak
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
- Correspondence: (M.S.); (M.W.)
| | - Ireneusz Sowa
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
| | - Katarzyna Tyszczuk-Rotko
- Faculty of Chemistry, Institute of Chemical Sciences, Maria Curie-Skłodowska University Lublin, 20-031 Lublin, Poland;
| | - Maciej Strzemski
- Department of Analytical Chemistry, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland; (I.S.); (M.S.)
| | - Sławomir Dresler
- Department of Plant Physiology and Biophysics, Maria Curie-Skłodowska University, 20-033 Lublin, Poland;
| | - Wojciech Myśliński
- Chair and Department of Internal Diseases, Medical University of Lublin, 20-081 Lublin, Poland;
| |
Collapse
|
18
|
Blumberg LM. Kinetic performance factor – a proportional metric for comparing performance of differently structured liguid chromatography columns. J Chromatogr A 2020; 1623:461101. [DOI: 10.1016/j.chroma.2020.461101] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Revised: 03/30/2020] [Accepted: 04/01/2020] [Indexed: 01/24/2023]
|
19
|
Hara T, Izumi Y, Hata K, V. Baron G, Bamba T, Desmet G. Performance of small-domain monolithic silica columns in nano-liquid chromatography and comparison with commercial packed bed columns with 2 µm particles. J Chromatogr A 2020; 1616:460804. [DOI: 10.1016/j.chroma.2019.460804] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Revised: 11/29/2019] [Accepted: 12/16/2019] [Indexed: 11/29/2022]
|
20
|
Futagami S, Hara T, Ottevaere H, Terryn H, Baron GV, Desmet G, De Malsche W. Chromatographic study of the structural properties of mesoporous silica layers deposited on radially elongated pillars. J Chromatogr A 2019; 1595:58-65. [DOI: 10.1016/j.chroma.2019.02.035] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2018] [Revised: 02/12/2019] [Accepted: 02/14/2019] [Indexed: 01/16/2023]
|
21
|
Hara T, Izumi Y, Nakao M, Hata K, Baron GV, Bamba T, Desmet G. Silica-based hybrid porous layers to enhance the retention and efficiency of open tubular capillary columns with a 5 μm inner diameter. J Chromatogr A 2018; 1580:63-71. [DOI: 10.1016/j.chroma.2018.10.023] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2018] [Revised: 10/09/2018] [Accepted: 10/14/2018] [Indexed: 12/16/2022]
|
22
|
Moreno-Marrodan C, Barbaro P, Caporali S, Bossola F. Low-Temperature Continuous-Flow Dehydration of Xylose Over Water-Tolerant Niobia-Titania Heterogeneous Catalysts. CHEMSUSCHEM 2018; 11:3649-3660. [PMID: 30106509 DOI: 10.1002/cssc.201801414] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Revised: 07/27/2018] [Indexed: 06/08/2023]
Abstract
The sustainable conversion of vegetable biomass-derived feeds to useful chemicals requires innovative routes meeting environmental and economical criteria. The approach herein pursued is the synthesis of water-tolerant, unconventional solid acid monolithic catalysts based on a mixed niobia-titania skeleton building up a hierarchical open-cell network of meso- and macropores, and tailored for use under continuous-flow conditions. The materials were characterized by spectroscopic, microscopy, and diffraction techniques, showing a reproducible isotropic structure and an increasing Lewis/Brønsted acid sites ratio with increasing Nb content. The catalytic dehydration reaction of xylose to furfural was investigated as a representative application. The efficiency of the catalyst was found to be dramatically affected by the niobia content in the titania lattice. The presence of as low as 2 wt % niobium resulted in the highest furfural yield at 140 °C under continuous-flow conditions, by using H2 O/γ-valerolactone as a safe monophasic solvent system. The interception of a transient 2,5-anhydroxylose species suggested the dehydration process occurs via a cyclic intermediates mechanism. The catalytic activity and the formation of the anhydro intermediate were related to the Lewis acid sites (LAS)/Brønsted acid sites (BAS) ratio and indicated a significant contribution of xylose-xylulose isomerization. No significant catalyst deactivation was observed over 4 days usage.
Collapse
Affiliation(s)
- Carmen Moreno-Marrodan
- Consiglio Nazionale delle Ricerche, Istituto di Chimica dei Composti Organo Metallici, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy
| | - Pierluigi Barbaro
- Consiglio Nazionale delle Ricerche, Istituto di Chimica dei Composti Organo Metallici, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy
| | - Stefano Caporali
- Consorzio Interuniversitario Nazionale per la Scienza e Tecnologia dei Materiali, Via Giusti 9, 50121, Firenze, Italy
- Consiglio Nazionale delle Ricerche, Istituto dei Sistemi Complessi, Via Madonna del Piano 10, 50019 Sesto Fiorentino, Firenze, Italy
| | - Filippo Bossola
- Consiglio Nazionale delle Ricerche, Istituto di Scienze e Tecnologie Molecolari, Via Golgi 19, 20133, Milano, Italy
| |
Collapse
|
23
|
Hara T, Futagami S, De Malsche W, Eeltink S, Terryn H, Baron GV, Desmet G. Chromatographic Properties of Minimal Aspect Ratio Monolithic Silica Columns. Anal Chem 2017; 89:10948-10956. [DOI: 10.1021/acs.analchem.7b02764] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Takeshi Hara
- Vrije Universiteit Brussel, Department of Chemical
Engineering, Pleinlaan
2, B-1050 Brussels, Belgium
- Division
of Metabolomics, Medical Institute of Bioregulation, Kyushu University, 3-1-1
Maidashi, Higashi-ku, Fukuoka 812-8582, Japan
| | - Shunta Futagami
- Vrije Universiteit Brussel, Department of Chemical
Engineering, Pleinlaan
2, B-1050 Brussels, Belgium
| | - Wim De Malsche
- Vrije Universiteit Brussel, Department of Chemical
Engineering, Pleinlaan
2, B-1050 Brussels, Belgium
| | - Sebastiaan Eeltink
- Vrije Universiteit Brussel, Department of Chemical
Engineering, Pleinlaan
2, B-1050 Brussels, Belgium
| | - Herman Terryn
- Vrije Universiteit Brussel, Department of Materials
and Chemistry, Pleinlaan
2, B-1050 Brussels, Belgium
| | - Gino V. Baron
- Vrije Universiteit Brussel, Department of Chemical
Engineering, Pleinlaan
2, B-1050 Brussels, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Department of Chemical
Engineering, Pleinlaan
2, B-1050 Brussels, Belgium
| |
Collapse
|
24
|
Svec F. Monolithic columns: A historical overview. Electrophoresis 2017; 38:2810-2820. [DOI: 10.1002/elps.201700181] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 05/20/2017] [Accepted: 05/23/2017] [Indexed: 11/11/2022]
Affiliation(s)
- Frantisek Svec
- Department of Analytical Chemistry, Faculty of Pharmacy; Charles University; Hradec Králové Czech Republic
| |
Collapse
|
25
|
Meinusch R, Ellinghaus R, Hormann K, Tallarek U, Smarsly BM. On the underestimated impact of the gelation temperature on macro- and mesoporosity in monolithic silica. Phys Chem Chem Phys 2017; 19:14821-14834. [DOI: 10.1039/c7cp01846k] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Elucidating pore formation in monolithic SiO2: small variations in gelation temperature have a surprisingly strong impact on the meso- and macroporosity.
Collapse
Affiliation(s)
- Rafael Meinusch
- Institute of Physical Chemistry
- Justus-Liebig-Universität Giessen
- 35392 Giessen
- Germany
- Center for Materials Research (LaMa)
| | - Rüdiger Ellinghaus
- Institute of Physical Chemistry
- Justus-Liebig-Universität Giessen
- 35392 Giessen
- Germany
- Center for Materials Research (LaMa)
| | - Kristof Hormann
- Department of Chemistry
- Philipps-Universität Marburg
- 35032 Marburg
- Germany
- Thermo Fisher Scientific
| | - Ulrich Tallarek
- Department of Chemistry
- Philipps-Universität Marburg
- 35032 Marburg
- Germany
| | - Bernd M. Smarsly
- Institute of Physical Chemistry
- Justus-Liebig-Universität Giessen
- 35392 Giessen
- Germany
- Center for Materials Research (LaMa)
| |
Collapse
|
26
|
Lambert N, Miyazaki S, Ohira M, Tanaka N, Felinger A. Comparison of the kinetic performance of different columns for fast liquid chromatography, emphasizing the contributions of column end structure. J Chromatogr A 2016; 1473:99-108. [DOI: 10.1016/j.chroma.2016.10.052] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2016] [Revised: 10/04/2016] [Accepted: 10/19/2016] [Indexed: 01/17/2023]
|
27
|
Characterization of the Kinetic Performance of Silica Monolithic Columns for Reversed-Phase Chromatography Separations. ADVANCES IN CHROMATOGRAPHY 2016. [DOI: 10.1201/9781315370385-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
28
|
Hara T, Futagami S, Eeltink S, De Malsche W, Baron GV, Desmet G. Very High Efficiency Porous Silica Layer Open-Tubular Capillary Columns Produced via in-Column Sol-Gel Processing. Anal Chem 2016; 88:10158-10166. [PMID: 27642813 DOI: 10.1021/acs.analchem.6b02713] [Citation(s) in RCA: 57] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
It is demonstrated that 5 μm i.d. capillaries can be coated with mesoporous silica layers up to 550 nm thickness. All the columns produced using in-column sol-gel synthesis with tetramethoxysilane provide plate height curves that closely follow the Golay-Aris theory. In 60 cm long columns, efficiencies as high as N = 150 000 and N = 120 000 were obtained, respectively, for a 300 and 550 nm thick porous layer. An excellent retention and plate height reproducibility was obtained when the recipes were subsequently applied to produce very long (1.9 and 2.5 m) capillaries. These columns produced efficiencies up to N = 600 000 plates for a retained and around N = 1 000 000 plates for an unretained component. Given the good reproducibility on the long capillaries, and considering that mesoporous silica is still the preferred support for LC, it is believed the present study could spur a renewed interest in open-tubular LC.
Collapse
Affiliation(s)
- Takeshi Hara
- Department of Chemical Engineering, Vrije Universiteit Brussels , Pleinlaan 2, 1050 Brussels, Belgium
| | - Shunta Futagami
- Department of Chemical Engineering, Vrije Universiteit Brussels , Pleinlaan 2, 1050 Brussels, Belgium
| | - Sebastiaan Eeltink
- Department of Chemical Engineering, Vrije Universiteit Brussels , Pleinlaan 2, 1050 Brussels, Belgium
| | - Wim De Malsche
- Department of Chemical Engineering, Vrije Universiteit Brussels , Pleinlaan 2, 1050 Brussels, Belgium
| | - Gino V Baron
- Department of Chemical Engineering, Vrije Universiteit Brussels , Pleinlaan 2, 1050 Brussels, Belgium
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussels , Pleinlaan 2, 1050 Brussels, Belgium
| |
Collapse
|
29
|
Recent developments in cyclodextrin functionalized monolithic columns for the enantioseparation of chiral drugs. J Pharm Biomed Anal 2016; 130:110-125. [DOI: 10.1016/j.jpba.2016.05.023] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2016] [Revised: 05/06/2016] [Accepted: 05/15/2016] [Indexed: 01/09/2023]
|
30
|
Agyei D, Ongkudon CM, Wei CY, Chan AS, Danquah MK. Bioprocess challenges to the isolation and purification of bioactive peptides. FOOD AND BIOPRODUCTS PROCESSING 2016. [DOI: 10.1016/j.fbp.2016.02.003] [Citation(s) in RCA: 144] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
31
|
Hara T, Desmet G, Baron GV, Minakuchi H, Eeltink S. Effect of polyethylene glycol on pore structure and separation efficiency of silica-based monolithic capillary columns. J Chromatogr A 2016; 1442:42-52. [DOI: 10.1016/j.chroma.2016.03.009] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 03/03/2016] [Accepted: 03/04/2016] [Indexed: 10/22/2022]
|
32
|
Acquah C, Moy CKS, Danquah MK, Ongkudon CM. Development and characteristics of polymer monoliths for advanced LC bioscreening applications: A review. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1015-1016:121-134. [PMID: 26919447 DOI: 10.1016/j.jchromb.2016.02.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 02/13/2016] [Accepted: 02/13/2016] [Indexed: 01/05/2023]
Abstract
Biomedical research advances over the past two decades in bioseparation science and engineering have led to the development of new adsorbent systems called monoliths, mostly as stationary supports for liquid chromatography (LC) applications. They are acknowledged to offer better mass transfer hydrodynamics than their particulate counterparts. Also, their architectural and morphological traits can be tailored in situ to meet the hydrodynamic size of molecules which include proteins, pDNA, cells and viral targets. This has enabled their development for a plethora of enhanced bioscreening applications including biosensing, biomolecular purification, concentration and separation, achieved through the introduction of specific functional moieties or ligands (such as triethylamine, N,N-dimethyl-N-dodecylamine, antibodies, enzymes and aptamers) into the molecular architecture of monoliths. Notwithstanding, the application of monoliths presents major material and bioprocess challenges. The relationship between in-process polymerisation characteristics and the physicochemical properties of monolith is critical to optimise chromatographic performance. There is also a need to develop theoretical models for non-invasive analyses and predictions. This review article therefore discusses in-process analytical conditions, functionalisation chemistries and ligands relevant to establish the characteristics of monoliths in order to facilitate a wide range of enhanced bioscreening applications. It gives emphasis to the development of functional polymethacrylate monoliths for microfluidic and preparative scale bio-applications.
Collapse
Affiliation(s)
- Caleb Acquah
- Curtin Sarawak Research Institute, Curtin University, Sarawak 98009, Malaysia; Department of Chemical Engineering, Curtin University, Sarawak 98009, Malaysia
| | - Charles K S Moy
- Department of Civil Engineering, Xi'an Jiaotong-Liverpool University, Jiangsu 215123, China
| | - Michael K Danquah
- Curtin Sarawak Research Institute, Curtin University, Sarawak 98009, Malaysia; Department of Chemical Engineering, Curtin University, Sarawak 98009, Malaysia.
| | - Clarence M Ongkudon
- Biotechnology Research Institute, Universiti Malaysia Sabah, Kota Kinabalu, Sabah 88400, Malaysia
| |
Collapse
|
33
|
Blumberg LM, Desmet G. Optimal Mixing Rate in Linear Solvent Strength Gradient Liquid Chromatography. Anal Chem 2016; 88:2281-8. [DOI: 10.1021/acs.analchem.5b04078] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
| | - Gert Desmet
- Department
of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, 1050 Brussels, Belgium
| |
Collapse
|
34
|
Sun MH, Huang SZ, Chen LH, Li Y, Yang XY, Yuan ZY, Su BL. Applications of hierarchically structured porous materials from energy storage and conversion, catalysis, photocatalysis, adsorption, separation, and sensing to biomedicine. Chem Soc Rev 2016; 45:3479-563. [DOI: 10.1039/c6cs00135a] [Citation(s) in RCA: 964] [Impact Index Per Article: 120.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
A comprehensive review of the recent progress in the applications of hierarchically structured porous materials is given.
Collapse
Affiliation(s)
- Ming-Hui Sun
- State Key Laboratory of Advanced Technology for Material Synthesis and Processing
- Wuhan University of Technology
- Wuhan 430070
- China
| | - Shao-Zhuan Huang
- State Key Laboratory of Advanced Technology for Material Synthesis and Processing
- Wuhan University of Technology
- Wuhan 430070
- China
| | - Li-Hua Chen
- State Key Laboratory of Advanced Technology for Material Synthesis and Processing
- Wuhan University of Technology
- Wuhan 430070
- China
| | - Yu Li
- State Key Laboratory of Advanced Technology for Material Synthesis and Processing
- Wuhan University of Technology
- Wuhan 430070
- China
| | - Xiao-Yu Yang
- State Key Laboratory of Advanced Technology for Material Synthesis and Processing
- Wuhan University of Technology
- Wuhan 430070
- China
| | - Zhong-Yong Yuan
- Collaborat Innovat. Ctr. Chem. Sci. & Engn. Tianjin
- Key Lab. Adv. Energy Mat. Chem
- Minist. Educ
- Coll. Chem
- Nankai Univ
| | - Bao-Lian Su
- State Key Laboratory of Advanced Technology for Material Synthesis and Processing
- Wuhan University of Technology
- Wuhan 430070
- China
- Laboratory of Inorganic Materials Chemistry (CMI)
| |
Collapse
|
35
|
Galarneau A, Sachse A, Said B, Pelisson CH, Boscaro P, Brun N, Courtheoux L, Olivi-Tran N, Coasne B, Fajula F. Hierarchical porous silica monoliths: A novel class of microreactors for process intensification in catalysis and adsorption. CR CHIM 2016. [DOI: 10.1016/j.crci.2015.05.017] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
36
|
Synthesis of the Coumarin-Containing Porous Silica as Column Packing Material. J Inorg Organomet Polym Mater 2015. [DOI: 10.1007/s10904-015-0293-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
37
|
Islas G, Rodríguez JA, Cruz-Borbolla J, Vásquez-Pérez JM, Barrado E. Synthesis and Characterization of Amide Stationary Phases for the Determination of Sulfonamides by Sequential Injection Chromatography. ANAL LETT 2015. [DOI: 10.1080/00032719.2015.1045589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
38
|
Feasibility of the preparation of silica monoliths for gas chromatography: Fast separation of light hydrocarbons. J Chromatogr A 2015; 1383:127-33. [DOI: 10.1016/j.chroma.2015.01.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2014] [Revised: 12/31/2014] [Accepted: 01/08/2015] [Indexed: 11/21/2022]
|
39
|
Meinusch R, Hormann K, Hakim R, Tallarek U, Smarsly BM. Synthesis and morphological characterization of phenyl-modified macroporous–mesoporous hybrid silica monoliths. RSC Adv 2015. [DOI: 10.1039/c4ra16519e] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
We present a comprehensive approach to characterize the one-pot synthesis, macropore space morphology, and chromatographic performance of phenyl-modified macro–mesoporous silica monoliths.
Collapse
Affiliation(s)
- Rafael Meinusch
- Institute of Physical Chemistry
- Justus-Liebig-Universität Giessen
- 35392 Giessen
- Germany
| | - Kristof Hormann
- Department of Chemistry
- Philipps-Universität Marburg
- 35032 Marburg
- Germany
| | - Romana Hakim
- Institute of Physical Chemistry
- Justus-Liebig-Universität Giessen
- 35392 Giessen
- Germany
- Thermo Fisher Scientific
| | - Ulrich Tallarek
- Department of Chemistry
- Philipps-Universität Marburg
- 35032 Marburg
- Germany
| | - Bernd M. Smarsly
- Institute of Physical Chemistry
- Justus-Liebig-Universität Giessen
- 35392 Giessen
- Germany
| |
Collapse
|
40
|
Monolithic and core–shell columns in comprehensive two-dimensional HPLC: a review. Anal Bioanal Chem 2014; 407:139-51. [DOI: 10.1007/s00216-014-8147-3] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Revised: 08/13/2014] [Accepted: 08/29/2014] [Indexed: 10/24/2022]
|
41
|
Lam E, Luong JH. Carbon Materials as Catalyst Supports and Catalysts in the Transformation of Biomass to Fuels and Chemicals. ACS Catal 2014. [DOI: 10.1021/cs5008393] [Citation(s) in RCA: 419] [Impact Index Per Article: 41.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Edmond Lam
- National Research
Council Canada, Montreal Building, Montreal, Quebec, Canada H4P2R2
| | - John H.T. Luong
- Irish
Separation Science Cluster (ISSC), Department of Chemistry, Analytical
and Biological Chemistry Research Facility (ABCRF), University College Cork, Cork, Ireland
| |
Collapse
|
42
|
Bicho D, Sousa Â, Sousa F, Queiroz J, Tomaz C. Effect of chromatographic conditions and plasmid DNA size on the dynamic binding capacity of a monolithic support. J Sep Sci 2014; 37:2284-92. [DOI: 10.1002/jssc.201400127] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2014] [Revised: 05/24/2014] [Accepted: 06/02/2014] [Indexed: 12/12/2022]
Affiliation(s)
- Diana Bicho
- CICS-UBI-Health Sciences Research Centre; University of Beira Interior, Av. Infante D. Henrique; Covilhã Portugal
| | - Ângela Sousa
- CICS-UBI-Health Sciences Research Centre; University of Beira Interior, Av. Infante D. Henrique; Covilhã Portugal
| | - Fani Sousa
- Department of Chemistry; University of Beira Interior; Covilhã Portugal
| | - João Queiroz
- CICS-UBI-Health Sciences Research Centre; University of Beira Interior, Av. Infante D. Henrique; Covilhã Portugal
- Department of Chemistry; University of Beira Interior; Covilhã Portugal
| | - Cãndida Tomaz
- CICS-UBI-Health Sciences Research Centre; University of Beira Interior, Av. Infante D. Henrique; Covilhã Portugal
- Department of Chemistry; University of Beira Interior; Covilhã Portugal
| |
Collapse
|
43
|
Hsieh ML, Chau LK, Hon YS. Single-step approach for fabrication of vancomycin-bonded silica monolith as chiral stationary phase. J Chromatogr A 2014; 1358:208-16. [PMID: 25047820 DOI: 10.1016/j.chroma.2014.07.003] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2014] [Revised: 06/28/2014] [Accepted: 07/02/2014] [Indexed: 12/01/2022]
Abstract
A vancomycin-bonded silica monolithic column for capillary electrochromatography (CEC) was prepared by a single-step in situ sol-gel approach. This sol-gel process incorporates a synthetic sol-gel precursor which contains a macrocyclic antibiotic, vancomycin, to form a porous silica network inside a fused-silica capillary. To avoid degradation of vancomycin during the column fabrication, a mild step was adopted into the sol-gel process. The performance of the vancomycin chiral stationary phase was investigated by CEC in both the reversed-phase mode and the normal-phase mode. The vancomycin chiral stationary phase was optimized with respect to vancomycin loading in the reversed-phase mode for chiral separation of thalidomide enantiomers. The best efficiency and resolution values of 94600plates/m and 5.79, respectively, were achieved. The optimized column was further applied to chiral separation of alprenolol enantiomers. A plate height of less than 7μm for the first eluted enantiomer of alprenolol was obtained in an aqueous mobile phase at a flow rate of 0.74mm/s. Using enantiomers of seven β-blockers and some other basic enantiomers as test analytes, separation efficiencies of up to 148100plates/m in the reversed-phase mode and up to 138100plates/m in the normal-phase mode were achieved.
Collapse
Affiliation(s)
- Ming-Lung Hsieh
- Department of Chemistry and Biochemistry, National Chung Cheng University, 168 University Road, Min-Hsiung, Chia-Yi 62102, Taiwan, ROC
| | - Lai-Kwan Chau
- Department of Chemistry and Biochemistry, National Chung Cheng University, 168 University Road, Min-Hsiung, Chia-Yi 62102, Taiwan, ROC; Center for Nano Bio-Detection and Advanced Institute of Manufacturing with High-tech Innovations, National Chung Cheng University, 168 University Road, Min-Hsiung, Chia-Yi 62102, Taiwan, ROC.
| | - Yung-Son Hon
- Department of Chemistry and Biochemistry, National Chung Cheng University, 168 University Road, Min-Hsiung, Chia-Yi 62102, Taiwan, ROC
| |
Collapse
|
44
|
Guo J, Lu Y, Zhang S. Preparation of a high specific surface area monolithic silica reversed phase chromatography column using a template induced method. NEW J CHEM 2014. [DOI: 10.1039/c4nj00662c] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
45
|
Tang S, Guo Y, Xiong C, Liu S, Liu X, Jiang S. Nanoparticle-based monoliths for chromatographic separations. Analyst 2014; 139:4103-17. [DOI: 10.1039/c4an00593g] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
46
|
Al-Othman ZA, Al-Warthan A, Ali I. Advances in enantiomeric resolution on monolithic chiral stationary phases in liquid chromatography and electrochromatography. J Sep Sci 2014; 37:1033-57. [DOI: 10.1002/jssc.201301326] [Citation(s) in RCA: 94] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2014] [Revised: 02/27/2014] [Accepted: 02/27/2014] [Indexed: 11/10/2022]
Affiliation(s)
- Zeid A. Al-Othman
- Department of Chemistry; College of Science; King Saud University; Riyadh Kingdom of Saudi Arabia
| | - Abdulrahman Al-Warthan
- Department of Chemistry; College of Science; King Saud University; Riyadh Kingdom of Saudi Arabia
| | - Imran Ali
- Department of Chemistry; Jamia Millia Islamia (Central University); New Delhi India
| |
Collapse
|
47
|
Szumski M, Buszewski B. Preparation of Monolithic Capillary Chromatographic Columns Using Supercritical Fluid as a Porogen Solvent. Chromatographia 2014; 77:1009-1017. [PMID: 25089047 PMCID: PMC4111859 DOI: 10.1007/s10337-014-2651-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2013] [Accepted: 02/24/2014] [Indexed: 11/09/2022]
Abstract
Monolithic polymeric beds were synthesized in fused silica capillaries using either trimethylolpropane trimethacrylate (TRIM) or a mixture of butyl methacrylate (BMA) with ethylene glycol dimethacrylate (EDMA) as monomers. Carbon dioxide at temperature and pressure conditions above its critical values was used as a porogen solvent. The purpose of using the supercritical carbon dioxide was to have the possibility of changing the solvation power (and thus the porosity of the resulting monolith) of the porogen by pressure and temperature changes instead of changing the porogen composition. The experiments were performed using a special setup consisting of a stainless steel high-pressure reactor to which the fused silica capillary was connected. The synthesized monoliths underwent liquid chromatographic evaluation. The polyTRIM capillary monoliths were characterized by different permeability, which depended on the pressure of the synthesis. BMA/EDMA columns were applied for separation of alkylbenzenes and a model mixture of proteins.
Collapse
Affiliation(s)
- Michał Szumski
- Faculty of Chemistry, Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Gagarina 7, 87-100 Toruń, Poland
| | - Bogusław Buszewski
- Faculty of Chemistry, Department of Environmental Chemistry and Bioanalytics, Nicolaus Copernicus University, Gagarina 7, 87-100 Toruń, Poland
| |
Collapse
|
48
|
Jandera P, Hájek T, Vyňuchalová K. Retention and bandwidths prediction in fast gradient liquid chromatography. Part 2-Core-shell columns. J Chromatogr A 2014; 1337:57-66. [PMID: 24636562 DOI: 10.1016/j.chroma.2014.02.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 02/07/2014] [Accepted: 02/10/2014] [Indexed: 11/25/2022]
Abstract
Recently, we confirmed that the well-established theory of gradient elution can be employed for prediction of retention in gradient elution from the isocratic data, method development and optimization in fast gradient chromatography employing short packed fully porous and monolithic columns and gradient times in between 1 and 2min, or even less. In the present work, we extended this study to short core-shell reversed-phase columns. We investigated the effects of the specification of the stationary phase in the core-shell structure on the prediction of gradient retention data. Two simple retention models describing the effects of the mobile phase on the retention by two-parameter equations yield comparable accuracy and can be used for prediction of elution times. The log-log model provides improved prediction of gradient bandwidths, especially for less retained compounds. A more sophisticated three-parameter model did not offer significant improvement of prediction. We compared the efficiency, selectivity and peak capacity of fast gradient separations of alkylbenzenes, phenolic acids and flavones on seven core shell columns with different lengths and chemistry of bonded shell stationary phase. Within the limits dictated by a fixed short separation time, appropriate adjustment of the range of the composition of mobile phase during gradient elution is the most efficient means to optimize the gradient separation. The gradient range affects sample bandwidths equally or even more significantly than the column length. Both 5-cm and 3-cm core-shell columns may provide comparable peak capacity in a fixed short gradient time.
Collapse
Affiliation(s)
- Pavel Jandera
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, CZ-53210 Pardubice, Czech Republic.
| | - Tomáš Hájek
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, CZ-53210 Pardubice, Czech Republic
| | - Kateřina Vyňuchalová
- Department of Analytical Chemistry, Faculty of Chemical Technology, University of Pardubice, Studentská 573, CZ-53210 Pardubice, Czech Republic
| |
Collapse
|
49
|
Aggarwal P, Asthana V, Lawson JS, Tolley HD, Wheeler DR, Mazzeo BA, Lee ML. Correlation of chromatographic performance with morphological features of organic polymer monoliths. J Chromatogr A 2014; 1334:20-9. [PMID: 24569008 DOI: 10.1016/j.chroma.2014.01.056] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2013] [Revised: 01/17/2014] [Accepted: 01/20/2014] [Indexed: 11/27/2022]
Abstract
Monoliths are considered to be a low pressure alternative to particle packed columns for liquid chromatography (LC). However, the chromatographic performance of organic monoliths, in particular, has still not reached the level of particle packed columns. Since chromatographic performance can be attributed to morphological features of the monoliths, in-situ characterization of the monolith structure in three dimensions would provide valuable information that could be used to help improve performance. In this work, serial sectioning and imaging were performed with a dual-beam scanning electron microscope for reconstruction and quantitative characterization of poly(ethylene glycol) diacrylate (PEGDA) monoliths inside a capillary column. Chord lengths, homogeneity factors, porosities and tortuosities were calculated from three-dimensional (3D) reconstructions of two PEGDA monoliths. Chromatographic efficiency was better for the monolith with smaller mean chord length (i.e., 5.23μm), porosity (i.e., 0.49) and tortuosity (i.e., 1.50) compared to values of 5.90μm, 0.59 and 2.34, respectively, for the other monolithic column. Computational prediction of tortuosity (2.32) was found to be in agreement with the experimentally measured value (2.34) for the same column. The monoliths were found to have significant radial heterogeneity since the homogeneity factor decreased from 5.39 to 4.89 (from center to edge) along the column radius.
Collapse
Affiliation(s)
- Pankaj Aggarwal
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA
| | | | - John S Lawson
- Department of Statistics, Brigham Young University, Provo, UT 84602, USA
| | - H Dennis Tolley
- Department of Statistics, Brigham Young University, Provo, UT 84602, USA
| | - Dean R Wheeler
- Department of Chemical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Brian A Mazzeo
- Department of Electrical Engineering, Brigham Young University, Provo, UT 84602, USA
| | - Milton L Lee
- Department of Chemistry and Biochemistry, Brigham Young University, Provo, UT 84602, USA.
| |
Collapse
|
50
|
Tang S, Liu S, Ren H, Liang X, Qiu H, Guo Y, Liu X, Jiang S. A novel imidazolium-based organic–silica hybrid monolith for per aqueous capillary electrochromatography. RSC Adv 2014. [DOI: 10.1039/c4ra03460k] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|