• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4591707)   Today's Articles (1619)   Subscriber (49315)
For: Gemalmaz D, Berksun S, Alkumru HN, Kasapoglu C. Thermal cycling distortion of porcelain fused to metal fixed partial dentures. J Prosthet Dent 1998;80:654-60. [PMID: 9830069 DOI: 10.1016/s0022-3913(98)70051-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Number Cited by Other Article(s)
1
Marginal fit of 3-unit implant-supported fixed partial dentures: Influence of pattern fabrication method and repeated porcelain firings. PLoS One 2024;19:e0301799. [PMID: 38625846 PMCID: PMC11020902 DOI: 10.1371/journal.pone.0301799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 03/23/2024] [Indexed: 04/18/2024]  Open
2
Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: An in vitro study. Eur J Dent 2014;7:272-277. [PMID: 24926205 PMCID: PMC4053614 DOI: 10.4103/1305-7456.115409] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022]  Open
3
Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method. J Adv Prosthodont 2012;4:89-92. [PMID: 22737313 PMCID: PMC3381208 DOI: 10.4047/jap.2012.4.2.89] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2012] [Revised: 05/02/2012] [Accepted: 05/07/2012] [Indexed: 11/08/2022]  Open
4
Effect of firing cycle and surface finishing on the sag resistance of long-span metal ceramic framework using base metal alloys-an in vitro study. Med J Armed Forces India 2012;68:145-50. [PMID: 24669055 DOI: 10.1016/s0377-1237(12)60016-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2010] [Accepted: 10/28/2011] [Indexed: 10/28/2022]  Open
5
Influence of cold working and thermal treatment on the fit of implant-supported metal-ceramic fixed partial dentures. J Prosthet Dent 2002;88:159-69. [PMID: 12397243 DOI: 10.1067/mpr.2002.127592] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
6
Annual review of selected dental literature: report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 1999;82:27-66. [PMID: 10384164 DOI: 10.1016/s0022-3913(99)70128-9] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]