1
|
Hwang SH, Oh HB, Kim HS, Lee EY. [Evaluation of HBs Ag, HCV and HIV Ag-Ab Assays using Bio-Rad Elite Microplate Analyzer.]. Korean J Lab Med 2012; 26:436-41. [PMID: 18156764 DOI: 10.3343/kjlm.2006.26.6.436] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND In this study, we evaluated the performance of Elite microplate analyzer (Bio-Rad Laboratories, France) and the related assays (ULTRA line) for the detection of hepatitis B virus (HBV), hepatitis C virus (HCV) and human immunodeficiency virus (HIV). METHODS Seroconversion panels, HBsAg positive/HBsAg negative (n=99/n=1,422), anti-HCV positive/negative (n=97/n=1,670), and anti-HIV positive/negative (n=112/n=1,704) samples were used to evaluate the performance of Monolisa HBsAg ULTRA, Monolisa HCV Ag-Ab ULTRA, and Genscreen ULTRA HIV Ag-Ab, respectively. The agreement of Elite microplate analyzer with CODA analyzer (Bio-Rad Laboratories, CA, USA) was also evaluated. RESULTS The detection limit of Monolisa HBsAg ULTRA was 0.034 IU/mL. For Monolisa HBsAg ULTRA, Monolisa HCV Ag-Ab ULTRA, and Genscreen ULTRA HIV Ag-Ab, diagnostic sensitivities were all 100%, diagnostic specificities were 100%, 99.8% and 99.9%, and total CVs (coefficients of variation) were 13.8-17.5%, 3.4-5.2%, and 7.5-9.5%, respectively. The agreement of Elite microplate analyzer with CODA analyzer was 99.5%. CONCLUSIONS The performance of Elite microplate analyzer and the related assays on analytical sensitivity, precision, early detection, diagnostic sensitivity and specificity was all adequate for a mass screening. However, further large multi-center studies should be performed to validate our results.
Collapse
Affiliation(s)
- Sang Hyun Hwang
- Department of Laboratory Medicine, Pusan National University School of Medicine, Busan, Korea.
| | | | | | | |
Collapse
|
2
|
Kee KM, Hung CM, Wang JH, Hung CH, Chen PF, Lin KS, Lu SN. Low accuracy of the national reporting system of acute hepatitis C infection in Taiwan, 1995-2004. J Gastroenterol Hepatol 2010; 25:1289-94. [PMID: 20594258 DOI: 10.1111/j.1440-1746.2010.06236.x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND AND AIM This study attempted to clarify accuracy of acute hepatitis C (AHC) and its clinical characteristics. METHODS We reviewed 632 reported cases from national surveillance data of the Taiwan Center for Disease Control between 1995 and 2004, and reclassified diagnoses. A definite case was defined as alanine aminotransferase (ALT) > 10 x the upper limit of normal (ULN) with seroconversion of anti-hepatitis C virus antibody (anti-HCV). A probable case was defined as (i) seroconversion of anti-HCV and/or elevated ALT levels; or (ii) anti-HCV(+) but titers increased (from < 40 S/CO to >or= 40 S/CO) and ALT > 10 x the ULN. A suspected case was defined as initial anti-HCV(+) and ALT level > 10 x the ULN and/or jaundice. Excluded cases were defined as ALT levels less than 10 x ULN with initial positive anti-HCV Ab. RESULTS A total of 310 (49%) cases were confirmed as AHC; these included 95 (15%) definite and 215 (34%) probable cases. Higher incidence rates and accuracy of AHC were demonstrated in the southern area significantly if compared with northern, eastern and central areas, respectively (all P < 0.05). On comparison between blood centers and hospitals, more AHC cases were found in Southern Taiwan than in other areas (157/73 vs 24/40, P < 0.001), younger mean age (33.3 +/- 11.1 vs 49.3 +/- 16.4, P < 0.001), lower ALT levels (263.1 +/- 200.9 vs 1264.2 +/- 706.8, P < 0.001) and male predominance (191/39 vs 46/18, P = 0.046). CONCLUSIONS This study showed our reporting system over-estimated the AHC diagnosis, which is also a common issue worldwide. Greater efforts are needed to establish appropriate reporting systems, as well as more supplemental methods to distinguish between prevalent and incident cases.
Collapse
Affiliation(s)
- Kwong-Ming Kee
- Division of Hepatogastroenterology, Department of Internal Medicine, Chang Gung Memorial Hospital-Kaohsiung Medical Center, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | | | | | | | | | | | | |
Collapse
|
3
|
Cherry CL, Affandi JS, Brew BJ, Creighton J, Djauzi S, Hooker DJ, Imran D, Kamarulzaman A, Kamerman P, McArthur JC, Moore RD, Price P, Smyth K, Tan IL, Vanar S, Wadley A, Wesselingh SL, Yunihastuti E. Hepatitis C seropositivity is not a risk factor for sensory neuropathy among patients with HIV. Neurology 2010; 74:1538-42. [PMID: 20458071 DOI: 10.1212/wnl.0b013e3181dd436d] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
BACKGROUND Sensory neuropathy (SN) is common in patients with HIV. Hepatitis C (HCV) coinfection is often cited as an HIV-SN risk factor, but data to support this are lacking. This collaboration aimed to examine the association between HCV serostatus and SN risk among ambulatory HIV-positive patients. METHODS Patients with HIV were assessed in cross-sectional studies in Baltimore, Jakarta, Johannesburg, Kuala Lumpur, Melbourne, and Sydney for SN (defined by both supportive symptoms and signs). HCV seropositivity was assessed as an SN risk using a chi(2) test, followed by logistic regression modeling to correct for treatment exposures and demographics. RESULTS A total of 837 patients of African, Asian, and Caucasian descent were studied. HCV seroprevalence varied by site (Baltimore n = 104, 61% HCV+; Jakarta 96, 51%; Johannesburg 300, 1%; Kuala Lumpur 97, 10%; Melbourne 206, 16%; Sydney 34, 18%). HCV seropositivity was not associated with increased SN risk at any site, but was associated with reduced SN risk in Melbourne (p = 0.003). On multivariate analyses, the independent associations with SN were increasing age, height, and stavudine exposure. HCV seropositivity was not independently associated with an increased SN risk at any site, but associated independently with reduced SN risk in Baltimore (p = 0.04) and Melbourne (p = 0.06). CONCLUSIONS Hepatitis C (HCV) seropositivity was not associated with increased sensory neuropathy risk among HIV-positive patients at any site. While we were unable to assess HCV RNA or liver damage, the data suggest that HCV coinfection is not a major contributor to HIV-SN. HCV = hepatitis C; SN = sensory neuropathy.
Collapse
Affiliation(s)
- C L Cherry
- The Alfred Hospital, Melbourne, Victoria 3004, Australia.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Sosa-Jurado F, Santos-López G, Guzmán-Flores B, Ruiz-Conde JI, Meléndez-Mena D, Vargas-Maldonado MT, Martínez-Laguna Y, Contreras-Mioni L, Vallejo-Ruiz V, Reyes-Leyva J. Hepatitis C virus infection in blood donors from the state of Puebla, Mexico. Virol J 2010; 7:18. [PMID: 20100349 PMCID: PMC2829021 DOI: 10.1186/1743-422x-7-18] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2009] [Accepted: 01/25/2010] [Indexed: 12/19/2022] Open
Abstract
Background Worldwide, 130 million persons are estimated to be infected with HCV. Puebla is the Mexican state with the highest mortality due to hepatic cirrhosis. Therefore, it is imperative to obtain epidemiological data on HCV infection in asymptomatic people of this region. The objective of present study was to analyze the prevalence of antibodies and genotypes of hepatitis C virus (HCV) in blood donors from Puebla, Mexico. Results The overall prevalence was 0.84% (515/61553). Distribution by region was: North, 0.86% (54/6270); Southeast, 1.04% (75/7197); Southwest, 0.93% (36/3852); and Central, 0.79% (350/44234). Ninety-six donors were enrolled for detection and genotyping of virus, from which 37 (38.5%) were HCV-RNA positive. Detected subtypes were: 1a (40.5%), 1b (27.0%), mixed 1a/1b (18.9%), undetermined genotype 1 (5.4%), 2a (2.7%), 2b (2.7%), and mixed 1a/2a (2.7%). All recovered donors with S/CO > 39 were HCV-RNA positive (11/11) and presented elevated ALT; in donors with S/CO < 39 HCV-RNA, positivity was of 30.4%; and 70% had normal values of ALT. The main risk factors associated with HCV infection were blood transfusion and surgery. Conclusions HCV prevalence of donors in Puebla is similar to other Mexican states. The most prevalent genotype is 1, of which subtype 1a is the most frequent.
Collapse
Affiliation(s)
- Francisca Sosa-Jurado
- Laboratorio de Biología Molecular y Virología, Centro de Investigación Biomédica de Oriente, Instituto Mexicano del Seguro Social, Puebla, Mexico
| | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Koyano S, Emi M, Saito T, Makino N, Toriyama S, Ishii M, Kubota I, Kato T, Kawata S. Common null variant, Arg192Stop, in a G-protein coupled receptor, olfactory receptor 1B1, associated with decreased serum cholinesterase activity. Hepatol Res 2008; 38:696-703. [PMID: 18328065 DOI: 10.1111/j.1872-034x.2008.00327.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
AIM Non-functioning single nucleotide polymorphisms (nSNPs) that result in premature termination codons, that is null-alleles of the respective genes, may have phenotypic effects on clinical parameters. We conducted association studies involving several G-protein coupled receptors (GPCRs) that harbor nSNPs, using clinical parameters of liver function in a general population consisting of 2969 Japanese adults. METHODS SNP typings were performed with TaqMan and Invader assays. Quantitative associations between genotypes and clinical parameters were analyzed by analysis of variance. Linkage disequilibrium (LD) was tested by Haploview Version 3.3. Haplotype-based association was performed using the haplo.stats program. RESULTS A significant correlation (P = 0.0057) was identified between serum cholinesterase activity (CHE) and an nSNP (Arg192Stop) in the olfactory receptor (OR) 1B1 gene, a member of the GPCR gene family. This nSNP was associated with decreased serum CHE (P = 0.0013). LD analysis based on eight selected SNPs at the locus revealed three LD blocks. The Arg192Stop nSNP was located on the second LD block, which covered one-third of the 3'-portion of the gene. CONCLUSION These results suggested that the null-allele of OR1B1 might affect metabolism of serum cholinesterase in carriers of this nSNP.
Collapse
Affiliation(s)
- Satoru Koyano
- Departments of Gastroenterology, Yamagata University School of Medicine, Yamagata, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Hung CH, Lu SN, Wang JH, Hung SF, Chen CH, Hu TH, Lee CM, Changchien CS. Identified cases of acute hepatitis C from computerized laboratory database: a hospital-based epidemiological and clinical study. J Infect 2008; 56:274-80. [PMID: 18346790 DOI: 10.1016/j.jinf.2008.01.049] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2007] [Revised: 12/19/2007] [Accepted: 01/29/2008] [Indexed: 12/18/2022]
Abstract
OBJECTIVE Diagnosis of acute hepatitis C (AHC) relies on documented positive-seroconversion of antibody to hepatitis C virus (anti-HCV) that is infrequently encountered. To clarify the epidemiology and clinical course of AHC, we tried to find more AHC patients from a computerized laboratory database by using a supplemental criterion of rising anti-HCV titer. METHODS All the computerized laboratory databases of anti-HCV and alanine aminotransferase (ALT) were reviewed. Candidates for AHC were identified by either anti-HCV positive seroconversion, rise of anti-HCV titer (signal to cut-off ratio (S/CO) ratio < 40 to > or = 40), or spontaneous HCV RNA clearance. AHC cases and their matched chronic hepatitis C controls were interviewed by a case-control study concerning risk factors. RESULTS AHC was identified in 123 patients (68 men and 55 women; median age: 48.4+/-13.9 years), who had higher rates of recent surgery (p=0.037) and frequent injection therapy (p=0.036) compared to controls. Self-limited AHC was observed in 18 (19.1%, 95% confidence interval: 12.3-25.9%) of 94 AHC patients who had been followed for 6 months, with a higher bilirubin level (> or = 2 vs. < 2, p=0.007) compared to those evolved to chronic infection. CONCLUSIONS Screening of a laboratory database for anti-HCV and ALT might uncover more AHC candidates to disclose the epidemiology and clinical course of AHC.
Collapse
Affiliation(s)
- Chao-Hung Hung
- Division of Hepatogastroenterology, Department of Internal Medicine, Chang Gung Memorial Hospital-Kaohsiung Medical Center, Chang Gung University College of Medicine, 123 Ta Pei Road, Niao Sung 833, Kaohsiung, Taiwan
| | | | | | | | | | | | | | | |
Collapse
|
7
|
Ivić I, Bradarić N, Puizina-Ivić N, Ledina D, Luksić B, Martinić R. Hla-Cw7 allele as predictor of favorable therapeutic response to interferon-alpha in patients with chronic hepatitis C. Croat Med J 2008; 48:807-13. [PMID: 18074415 DOI: 10.3325/cmj.2007.6.807] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
AIM To evaluate the association between human leukocyte antigens (HLA) class I and therapeutic response to interferon-alpha in Croatian patients with chronic hepatitis C. METHODS HLA-A, -B, and -C genotyping was performed in 55 patients with sustained virological response and in 57 patients without sustained virological response to interferon-alpha therapy. Patients were treated in the period from 1998-2001 with interferon-alpha at a dose of 3 million units three times a week. Patients who became negative for hepatitis C virus RNA after 12 weeks of therapy completed 48 weeks of therapy. RESULTS There was no association between therapeutic outcome and frequency of HLA-A, as well as of HLA-B alleles. HLA-Cw7 was significantly more frequent in patients with than those without sustained virological response (27.0% vs 6.7%; P=0.011). CONCLUSION In Croatian patients with chronic hepatitis C, HLA-Cw7 is the predictor of sustained virological response to interferon-alpha therapy.
Collapse
Affiliation(s)
- Ivo Ivić
- Department for Infectious Diseases, Split University Hospital, Split, Croatia.
| | | | | | | | | | | |
Collapse
|
8
|
Hwang SH, Oh HB, Chae JM, Seo MK, Jung SY, Choi SE, Lee KJ. [Development of a Web-based Program to Calculate Sample Size for Evaluating the Performance of In Vitro Diagnostic Kits.]. Korean J Lab Med 2007; 26:299-306. [PMID: 18156742 DOI: 10.3343/kjlm.2006.26.4.299] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Many studies evaluating the performance of in vitro diagnostic kits have been criticized for the lack of reliability. To attain reliability those evaluation studies should be preceded by sample size calculation ensuring statistical power. This study was intended to develop a web-based system to estimate the sample size, which was often neglected because it would require expert knowledge in statistics. METHODS For sample size calculation, we extracted essential parameters from the performance studies on the 3rd generation anti-hepatitis C virus (HCV) kits reported in the literature. We developed a system with PHP web-script language and MySQL. The statistical models used in this system were as follows; one sample without power consideration (model 1), one sample with power consideration (model 2), and two samples with power consideration (model 3). RESULTS Among the articles published between 1989 and 2005, 13 articles that evaluated the performance of anti-HCV kits were identified by searching with Medical Subject Headings (MeSH). The diagnostic sensitivity was 83-100% with a median of 145 samples (range; 12-1,091) and the specificity was 97-100% with a median of 1,025 samples (range; 33-4,381). The estimated sample size would be 280 in the model 1, 817 in the model 2, and 1,510 in the model 3, when we set 2% prevalence of HCV infection, 95% sensitivity of a conventional kit, 97% sensitivity of a new kit , 95% significance level (two-sided test), 2% allowable error, and 80% power. CONCLUSIONS Our study indicates that an insufficient sample size is still a problem in performance evaluation. Our system should be helpful in increasing the reliability of performance evaluation by providing an appropriate sample size.
Collapse
Affiliation(s)
- Sang Hyun Hwang
- Department of Laboratory Medicine, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.
| | | | | | | | | | | | | |
Collapse
|
9
|
Kim S, Oh HB, Cha CH, Choi SE, M.A., An HY, Lee KJ. Quality Evaluation of the Performance Study of Diagnostic Tests Using STARD Checklist andMeta-Analysis for the Pooled Sensitivity and Specificity of Third Generation Anti-HCV EIA Tests. Ann Lab Med 2006; 26:307-15. [DOI: 10.3343/kjlm.2006.26.4.307] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Affiliation(s)
- Sollip Kim
- Department of Laboratory Medicine, Asan Medical Center and University of Ulsan College of Medicine, Seoul, Korea
| | - Heung-Bum Oh
- Department of Laboratory Medicine, Asan Medical Center and University of Ulsan College of Medicine, Seoul, Korea
| | - Chung-Hwan Cha
- Department of Laboratory Medicine, Asan Medical Center and University of Ulsan College of Medicine, Seoul, Korea
| | - Sung-Eun Choi
- Department of Laboratory Medicine, Asan Medical Center and University of Ulsan College of Medicine, Seoul, Korea
| | - M.A.
- Department of Laboratory Medicine, Asan Medical Center and University of Ulsan College of Medicine, Seoul, Korea
| | - Hong-yup An
- Department of Laboratory Medicine, Asan Medical Center and University of Ulsan College of Medicine, Seoul, Korea
| | - Kwan Jeh Lee
- Department of Laboratory Medicine, Asan Medical Center and University of Ulsan College of Medicine, Seoul, Korea
| |
Collapse
|
10
|
Cruz JR, Pérez-Rosales MD, Zicker F, Schmunis GA. Safety of blood supply in the Caribbean countries: Role of screening blood donors for markers of hepatitis B and C viruses. J Clin Virol 2005; 34 Suppl 2:S75-80. [PMID: 16461244 DOI: 10.1016/s1386-6532(05)80038-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Blood transfusions carry risks of untoward reactions, including the transmission of infections, such as hepatitis B and C. Proper blood donor recruitment and selection, and adequate laboratory screening for infectious markers diminish the risk of transfusion-transmitted infections. OBJECTIVES To estimate the potential risk of acquiring transfusion-transmitted infections by hepatitis B or hepatitis C in 24 Caribbean countries during the period of 1996 to 2003. STUDY DESIGN Official national reports for 1996, 2000-2003 of the yearly number of blood donors, screening coverage, and prevalence of serological markers for infectious diseases were used to estimate the risk of patients receiving an HBV- or HCV-positive unit of blood, and of developing an infection after receiving a positive unit. Estimates of number of infections transmitted through transfusion and number of infections prevented by screening of blood were also obtained. RESULTS During the period analyzed, HBV screening coverage among blood donors was 100% in all countries with the exception of Grenada (0% in 1996) and Saint Lucia (99.5% in 2002). For HCV, only 10 countries reported universal screening in 1996, while 15 did in 2003. The number of countries that did not screen any units for HCV decreased from 11 in 1996 to five in 2003. In general, high prevalence rates of HBV (10-75 per 1000 donors) and HCV (7-19.3 per 1000 donors) markers were found in the majority of countries. We estimated that 235 infections by HCV (1:12471 donations) and two infections by HBV (1:1465373) were transmitted through transfusion because of lack of screening. On the other hand, screening of blood for transfusion prevented 21 005 HCV and 22 100 HBV infections. CONCLUSIONS Blood donor recruitment and coverage of screening for transfusion-transmitted infections, especially HCV, must be improved in the Caribbean countries.
Collapse
Affiliation(s)
- Jose R Cruz
- Pan American Health Organization, Regional Office of the World Health Organization for the Americas. 525 23rd. St, NW, Washington, DC 20037, USA.
| | | | | | | |
Collapse
|
11
|
Zachary P, Ullmann M, Djeddi S, Meyer N, Wendling MJ, Schvoerer E, Stoll-Keller F, Gut JP. Evaluation of three commercially available hepatitis C virus antibody detection assays under the conditions of a clinical virology laboratory. J Clin Virol 2005; 34:207-10; discussion 216-8. [PMID: 16122975 DOI: 10.1016/j.jcv.2005.06.005] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2005] [Revised: 05/29/2005] [Accepted: 06/09/2005] [Indexed: 12/09/2022]
Abstract
BACKGROUND Most studies evaluating antibody detection assays are conducted on samples from healthy blood donors but not on samples of hospitalized patients which can show non-specific reactions. OBJECTIVES To compare the performance of three commercial automated assays for the detection of hepatitis C virus (HCV) antibodies, Monolisa anti-HCV Plus version 2, Axsym anti-HCV 3.0 and Vitros anti-HCV, on a population of hospitalized patients. STUDY DESIGN The specificity of the assays was prospectively evaluated in 2020 routine serum samples. In order to assign the serostatus of each sample, those giving positive or discordant results were further tested by three immunoblots and by RT-PCR (Roche). Moreover, the sensitivity was evaluated on eight commercial HCV seroconversion panels. RESULTS The Monolisa, Axsym and Vitros assays showed specificities of 99.64%, 99.12% and 99.33%, respectively. Concerning the sensitivity, among 49 samples, the number of positive results was 21, 24 and 24 for the Monolisa, Axsym and Vitros kits, respectively. The differences were not statistically significant at an alpha risk of 5%. CONCLUSIONS All assays appeared to be reliable for routine screening, but there were a surprising number of indeterminate samples that could not be resolved by confirmatory tests.
Collapse
Affiliation(s)
- Pierre Zachary
- Laboratoire de Virologie, Hôpitaux Universitaires de Strasbourg, 3 rue Koeberle, 67000 Strasbourg, France.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Zachary P, Ullmann M, Djeddi S, Wendling MJ, Schvoerer E, Stoll-Keller F, Gut JP. Évaluation de deux trousses commerciales EIA pour le diagnostic de l’hépatite C dans les conditions d’un laboratoire de virologie. ACTA ACUST UNITED AC 2004; 52:511-6. [PMID: 15531114 DOI: 10.1016/j.patbio.2004.07.030] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2004] [Accepted: 07/16/2004] [Indexed: 10/26/2022]
Abstract
BACKGROUND Most studies which evaluate antibody detection assays are conducted on blood donors specimens, i.e healthy individuals. Sera collected in patients, vs healthy individuals, can make serological tests difficult because of possible non specific reactions interfering with serological tests. The aim of this work was to compare the specificity and the sensitivity of two commercial automated assays for the detection of hepatitis C virus antibody, Monolisa anti-HCV Plus on the Evolis automate (Biorad) and Axsym anti-HCV 3.0 (Abbott). PATIENTS AND METHOD The prospective study of specificity included 2020 routine serum samples sent to our virology laboratory. The sensitivity was established with eight commercially available HCV seroconversion panels. RESULTS The Monolisa and the Axsym assays showed a specificity of 99.64 and 99.12%, respectively. Of 49 specimens from eight commercially available HCV seroconversion panels, the number of positive results was 21 and 24 for the two tests, respectively. CONCLUSION A statistical analysis of specificity and sensitivity results proved no significant difference between the two tests. Nevertheless, the Monolisa kits could be preferred for its more homogeneous sensitivity than the Axsym test and for its apparent better specificity. The final choice of a kit should also take into account the easiness to perform and an optimal integration in the usual practice of the concerned laboratory.
Collapse
Affiliation(s)
- P Zachary
- Institut de virologie faculté de médecine, 3, rue Koeberlé 67000 Strasbourg, France.
| | | | | | | | | | | | | |
Collapse
|
13
|
Lu SN, Tung HD, Chen TM, Lee CM, Wang JH, Hung CH, Chen CH, Changchien CS. Is it possible to diagnose acute hepatitis C virus (HCV) infection by a rising anti-HCV titre rather than by seroconversion? J Viral Hepat 2004; 11:563-70. [PMID: 15500558 DOI: 10.1111/j.1365-2893.2004.00533.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
The diagnosis of acute hepatitis C virus (HCV) infection relies on documented positive-seroconversion of HCV antibody (anti-HCV). Because of the detection of seroconversion at an earlier stage by second or third generation anti-HCV enzyme immunoassays (EIA), the diagnosis of acute hepatitis C (AHC) may be underestimated. The aim of this study was to evaluate whether rising anti-HCV titre could be used to diagnose AHC or not. Eighteen patients with a clinical diagnosis of acute hepatitis C were enrolled, including eight cases with documented seroconversion to anti-HCV and 10 cases with clinically suspected acute hepatitis C. Four chronic hepatitis C patients with acute exacerbation were selected as a control group. Serial sera were assayed with a third generation anti-HCV (AxSYM, version 3.0; Abbott, Chicago, IL, USA) and recombinant immunoblot assays (RIBA; Chiron HCV 3.0 Strip; Immunoblot, Emeryville, CA, USA) and the titre of anti-HCV expressed as signal/cutoff (S/CO) ratio and the RIBA patterns were correlated. Seven of eight documented AHC (one lacking the initial serum) and five of 10 clinically suspected AHC showed a rising pattern of S/CO values. The initial S/CO values on the first visit were less than 40 in 14 of 18 cases. The RIBA pattern shifted from negative/indeterminate to positive in five of seven documented AHC and 4 of 10 clinically suspected AHC cases. Fifteen of 18 cases had seroconversions of at least one antibody, whilst 85.7% showed a rising S/CO ratio. On the contrary, the S/CO ratio and RIBA pattern remained unaltered in chronic hepatitis C with acute exacerbation. The rise in S/CO was usually accompanied with an increase in the number of RIBA reactive bands and their intensity in acute hepatitis C patients. The rise in S/CO ratios using a third generation anti-HCV assay and the RIBA pattern might be used as a supplemental diagnostic criterion for acute HCV infection.
Collapse
Affiliation(s)
- S-N Lu
- Division of Hepato-Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Niaosung, Kaohsiung, Taiwan.
| | | | | | | | | | | | | | | |
Collapse
|
14
|
Loubière S, Rotily M, Moatti JP. Prevention could be less cost-effective than cure: the case of hepatitis C screening policies in France. Int J Technol Assess Health Care 2004; 19:632-45. [PMID: 15095769 DOI: 10.1017/s026646230300059x] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVES To access the cost-effectiveness of French recommendations for hepatitis C virus (HCV) screening and the extent to which earlier identification of carriers may or not improve the cost-effectiveness of therapeutic strategies. METHODS Cost-effectiveness analysis were performed using decision-tree analysis and a Markov model. Four alternative strategies were compared: no screening and no treatment; initiation of HCV treatment after the diagnosis of cirrhosis; and two alternative strategies refer to the current French policies of HCV testing, i.e., two enzyme immunoblot assay (EIA) tests in series, or a polymerase chain reaction (PCR) analysis after the first positive EIA test. Costs were computed from the viewpoint of the health care system. The analysis has been applied to populations particularly at risk of infection, as well as the general population. RESULTS The "wait and treat cirrhosis" strategy was more cost-effective in the general population and in transfusion recipients. The incremental cost-effectiveness ratio of this strategy compared with baseline strategy was 3,476 of euros and Euro15,300 in respective cohorts. Considering the HCV screening strategy, the additional cost would be of Euro4,933 and Euro240,250 per additional year of life saved, respectively. In the intravenous drug user (IDU) population, the "two ElA" screening strategy was the more cost-effective alternative, with an additional cost of Euro3,825 per additional year of life saved. CONCLUSIONS HCV screening would be discarded for transfusion recipients but should be encouraged for IDUs and also for the general population, in which the additional cost of screening is an order of magnitude more acceptable.
Collapse
Affiliation(s)
- Sandrine Loubière
- The French Medical Institute of Medical Research, INSERM U379-ORS PACA, Marseille, France.
| | | | | |
Collapse
|
15
|
Bossi V, Galli C. Quantitative signal of anti-HCV by an automated assay predicts viremia in a population at high prevalence of hepatitis C virus infection. J Clin Virol 2004; 30:45-9. [PMID: 15072753 DOI: 10.1016/j.jcv.2003.08.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/15/2003] [Indexed: 11/23/2022]
Abstract
BACKGROUND AND AIMS The diagnosis of ongoing hepatitis C virus (HCV) infection involves the detection of specific antibodies and of HCV-RNA. We aimed to assess the relationship between these two parameters in a representative sample of a population at high risk for HCV infection. METHODS Plasma and serum samples were respectively tested for HCV-RNA by a qualitative PCR (Cobas Amplicor HCV, Roche) and for HCV antibodies by a MEIA screening assay (AxSYM HCV 3.0, Abbott) and an immunoblot (Inno-LIA-III, Innogenetics). RESULTS AND CONCLUSIONS Out of 888 samples assayed, 579 (65.2%) were positive for HCV-RNA, while anti-HCV antibodies were detected respectively in 802 sera by AxSYM (90.3%) and in 783 by LIA (706 positive and 77 indeterminate, 88.2%). The anti-core antibodies displayed the best correlation with viremia, since they were present in 97.1% of the PCR+ samples, followed by anti-NS3 (90.2%) and anti-NS4 (89.6%). Only one HCV-RNA positive sample was negative by LIA and MEIA (early seroconversion). The AxSYM sample/cutoff (S/CO) values were directly correlated with the presence of HCV-RNA: a PCR positivity was found in 4.9% of samples with a S/CO < or =10, in 60.8% of samples with a S/CO between 11 and 50 and in 93.6% of cases with a S/CO >50, (P < 0.005). The immunoblot adds little, on a single specimen, to the information yielded by the AxSYM screening test. A suitable diagnostic algorithm for HCV in high-risk settings could be the anti-HCV screening by MEIA and a qualitative assay for HCV-RNA on samples with low reactivity.
Collapse
Affiliation(s)
- Vincenzo Bossi
- Virology, Ospedale Amedeo di Savoia, corso Svizzera 164, 10100 Turin, Italy
| | | |
Collapse
|
16
|
Ismail N, Fish GE, Smith MB. Laboratory evaluation of a fully automated chemiluminescence immunoassay for rapid detection of HBsAg, antibodies to HBsAg, and antibodies to hepatitis C virus. J Clin Microbiol 2004; 42:610-7. [PMID: 14766824 PMCID: PMC344481 DOI: 10.1128/jcm.42.2.610-617.2004] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2003] [Revised: 08/31/2003] [Accepted: 11/04/2003] [Indexed: 12/11/2022] Open
Abstract
The performance of a fully automated, random access, enhanced chemiluminescence immunoassay (Ortho/ECi) for the detection of antibody to hepatitis C virus (HCV) (anti-HCV), HBsAg, and antibody to HBsAg (anti-HBsAg), in human serum was compared to a Abbott second-generation enzyme immunoassay (EIA 2.0). The Ortho/ECi assays employ an immunometric technique with enhanced chemiluminescence for optimal assay performance. With regard to the study of clinical laboratory performance, six groups of sera prescreened with Abbott EIAs were assayed: anti-HCV-negative samples (n = 318), anti-HCV-positive samples (n = 177), anti-HBsAg-negative samples (n = 241), anti-HBsAg-positive samples (n = 239), HBsAg-positive samples (n = 158), and HBsAg-negative samples (n = 312). Sera with discrepant results in the two serological assays were resolved by confirmatory tests. Sera with indeterminate results by one or more confirmatory tests were evaluated by reviewing medical records. The overall concordance between the Ortho/ECi assay and the Abbott EIA were 97.78, 93.54, and 97.66% for anti-HCV antibodies, anti-HBsAg antibodies, and HBsAg, respectively. After resolving the discrepancies, the specificities of the new assay for anti-HCV and anti-HBsAg antibodies and HBsAg were 98.1, 92.8, and 100%, respectively. The sensitivities of the new assay for anti-HCV, anti-HBsAg, and HBsAg were 100, 98.8, and 97.4%, respectively. In conclusion, The Ortho/ECi assays for diagnosis of HCV and hepatitis B virus (HBV) infections are highly specific and sensitive assays. The rapid turnaround time, random access, full automation, and high throughput make it an effective assay system for clinical laboratory diagnosis of HCV and HBV infections.
Collapse
Affiliation(s)
- Nahed Ismail
- Department of Pathology, University of Texas Medical Branch, Galveston, Texas 77555, USA.
| | | | | |
Collapse
|
17
|
Tung HD, Lu SN, Lee CM, Wang JH, Chen TM, Hung CH, Huang WS, Changchien CS. Antiviral treatment responses in patients with chronic hepatitis C virus infection evaluated by a third generation anti-hepatitis C virus assay. J Viral Hepat 2002; 9:304-8. [PMID: 12081608 DOI: 10.1046/j.1365-2893.2002.00359.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
Antibodies to hepatitis C virus (HCV) may decrease or disappear after viral clearance in treated or spontaneously resolved infection. We evaluated the usefulness of serial antibody assays in predicting the antiviral treatment responses. One hundred and four chronic hepatitis C patients who received 24 weeks of interferon and ribavirin combination therapy were assayed with a third generation enzyme immunoassay anti-HCV. The mean titre of anti-HCV decreased by more than 50% (from 89.5 +/- 10.8 to 43.6 +/- 17.5) at 48 weeks post-treatment in patients with a sustained virological response, while in nonsustained virological responders and nonresponders, the titres remained over 85% of the pretreatment level at 48 weeks post-treatment. There was a divergence of anti-HCV titres between sustained and nonsustained virological responders during 6-9 months. By using the ratio of 9-month to 6-month titres as an index and receiver operator characteristic curve analysis with the cut-off point set at 90%, we could differentiate sustained virological responders from nonsustained virological responders with a sensitivity and specificity of 91.7% and 90.9%, respectively, 3 months after treatment. The titre of this third generation anti-HCV decreased progressively in sustained virological responders and this assay may be used to monitor and predict antiviral treatment responses.
Collapse
Affiliation(s)
- H-D Tung
- Division of Gastroenterology, Department of Internal Medicine, Kaohsiung Chang Gung Memorial Hospital, Kaohsiung, Taiwan
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Literature alerts. J Microencapsul 2000; 17:657-69. [PMID: 11038124 DOI: 10.1080/026520400417702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
|