1
|
Nakamura S, Imamichi S, Shimada K, Takemori M, Kanai Y, Iijima K, Chiba T, Nakayama H, Nakaichi T, Mikasa S, Urago Y, Kashihara T, Takahashi K, Nishio T, Okamoto H, Itami J, Ishiai M, Suzuki M, Igaki H, Masutani M. Relative biological effectiveness for epithermal neutron beam contaminated with fast neutrons in the linear accelerator-based boron neutron capture therapy system coupled to a solid-state lithium target. JOURNAL OF RADIATION RESEARCH 2023:7192974. [PMID: 37295954 PMCID: PMC10354855 DOI: 10.1093/jrr/rrad037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 01/30/2023] [Indexed: 06/12/2023]
Abstract
This study aimed to quantify the relative biological effectiveness (RBE) for epithermal neutron beam contaminated with fast neutrons in the accelerator-based boron neutron capture therapy (BNCT) system coupled to a solid-state lithium target. The experiments were performed in National Cancer Center Hospital (NCCH), Tokyo, Japan. Neutron irradiation with the system provided by Cancer Intelligence Care Systems (CICS), Inc. was performed. X-ray irradiation, which was assigned as the reference group, was also performed using a medical linear accelerator (LINAC) equipped in NCCH. The four cell lines (SAS, SCCVII, U87-MG and NB1RGB) were utilized to quantify RBE value for the neutron beam. Before both of those irradiations, all cells were collected and dispensed into vials. The doses of 10% cell surviving fraction (SF) (D10) were calculated by LQ model fitting. All cell experiments were conducted in triplicate at least. Because the system provides not only neutrons, but gamma-rays, the contribution from the gamma-rays to the survival fraction were subtracted in this study. D10 value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was 4.26, 4.08, 5.81 and 2.72 Gy, respectively, while that acquired by the X-ray irradiation was 6.34, 7.21, 7.12 and 5.49 Gy, respectively. Comparison of both of the D10 values, RBE value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was calculated as 1.7, 2.2, 1.3 and 2.5, respectively, and the average RBE value was 1.9. This study investigated RBE of the epithermal neutron beam contaminated with fast neutrons in the accelerator-based BNCT system coupled to a solid-state lithium target.
Collapse
Affiliation(s)
- Satoshi Nakamura
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita city, Osaka, 565-0871, Japan
| | - Shoji Imamichi
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Central Radioisotope Division, National Cancer Center Research Institute, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Department of Molecular and Genomic Biomedicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8588, Japan
| | - Kenzi Shimada
- Cancer Intelligence Care Systems, Inc. 3-5-7 Ariake, Koto-ku, Tokyo, 135-0063, Japan
| | - Mihiro Takemori
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Department of Radiological Science, Graduate School of Human Health Sciences, 7-2-10 Higashi-ogu, Arakawa-ku, Tokyo, 116-8551, Japan
| | - Yui Kanai
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Central Radioisotope Division, National Cancer Center Research Institute, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Laboratory for Zero-Carbon Energy, Institute of Innovative Research, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo, 152-5880, Japan
| | - Kotaro Iijima
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Takahito Chiba
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Department of Radiological Science, Graduate School of Human Health Sciences, 7-2-10 Higashi-ogu, Arakawa-ku, Tokyo, 116-8551, Japan
| | - Hiroki Nakayama
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Department of Radiological Science, Graduate School of Human Health Sciences, 7-2-10 Higashi-ogu, Arakawa-ku, Tokyo, 116-8551, Japan
| | - Tetsu Nakaichi
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Shohei Mikasa
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Yuka Urago
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Department of Radiological Science, Graduate School of Human Health Sciences, 7-2-10 Higashi-ogu, Arakawa-ku, Tokyo, 116-8551, Japan
| | - Tairo Kashihara
- Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Kana Takahashi
- Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Teiji Nishio
- Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita city, Osaka, 565-0871, Japan
| | - Hiroyuki Okamoto
- Division of Radiation Safety and Quality Assurance, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Jun Itami
- Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Masamichi Ishiai
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Central Radioisotope Division, National Cancer Center Research Institute, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Minoru Suzuki
- Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2 Asashiro-Nishi, Kumatori-cho, Sennan-gun, Osaka, 590-0494, Japan
| | - Hiroshi Igaki
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Department of Radiation Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
| | - Mitsuko Masutani
- Division of Boron Neutron Capture Therapy, Exploratory Oncology Research & Clinical Trial Center, National Cancer Center, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Central Radioisotope Division, National Cancer Center Research Institute, 5-1-1 Tsukiji, Chuo-ku, Tokyo, 104-0045, Japan
- Department of Molecular and Genomic Biomedicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8588, Japan
| |
Collapse
|
2
|
Hirose K, Kato T, Harada T, Motoyanagi T, Tanaka H, Takeuchi A, Kato R, Komori S, Yamazaki Y, Arai K, Kadoya N, Sato M, Takai Y. Determining a methodology of dosimetric quality assurance for commercially available accelerator-based boron neutron capture therapy system. JOURNAL OF RADIATION RESEARCH 2022; 63:620-635. [PMID: 35726375 PMCID: PMC9303606 DOI: 10.1093/jrr/rrac030] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 01/20/2021] [Indexed: 06/15/2023]
Abstract
The irradiation field of boron neutron capture therapy (BNCT) consists of multiple dose components including thermal, epithermal and fast neutron, and gamma. The objective of this work was to establish a methodology of dosimetric quality assurance (QA), using the most standard and reliable measurement methods, and to determine tolerance level for each QA measurement for a commercially available accelerator-based BNCT system. In order to establish a system of dosimetric QA suitable for BNCT, the following steps were taken. First, standard measurement points based on tissue-administered doses in BNCT for brain tumors were defined, and clinical tolerances of dosimetric QA measurements were derived from the contribution to total tissue relative biological effectiveness factor-weighted dose for each dose component. Next, a QA program was proposed based on TG-142 and TG-198, and confirmed that it could be assessed whether constancy of each dose component was assured within the limits of tolerances or not by measurements of the proposed QA program. Finally, the validity of the BNCT QA program as an evaluation system was confirmed in a demonstration experiment for long-term measurement over 1 year. These results offer an easy, reliable QA method that is clinically applicable with dosimetric validity for the mixed irradiation field of accelerator-based BNCT.
Collapse
Affiliation(s)
- Katsumi Hirose
- Corresponding author. Southern Tohoku BNCT Research Center, 7-10 Yatsuyamada, Koriyama, 963-8052 Japan, Tel: +81-24-934-5330,
| | - Takahiro Kato
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
- Department of Radiation Oncology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
- School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima 960-8516, Japan
| | - Takaomi Harada
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| | - Tomoaki Motoyanagi
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| | - Hiroki Tanaka
- Particle Radiation Oncology Research Center, Institute for Integrated Radiation and Nuclear Science, Kyoto University, 2 Asashiro-nisi, Sennan-gun, Osaka 590-0494, Japan
| | - Akihiko Takeuchi
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| | - Ryohei Kato
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| | - Shinya Komori
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| | - Yuhei Yamazaki
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| | - Kazuhiro Arai
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
- Department of Radiation Oncology, Southern Tohoku Proton Therapy Center, 7-172 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| | - Noriyuki Kadoya
- Department of Radiation Oncology, Tohoku University School of Medicine, 1-1 Seiryo-machi, Aoba-ku, Sendai 980-8574, Japan
| | - Mariko Sato
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
- Department of Radiology and Radiation Oncology, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki, Aomori 036-8562, Japan
| | - Yoshihiro Takai
- Department of Radiation Oncology, Southern Tohoku BNCT Research Center and Southern Tohoku General Hospital, 7-10 Yatsuyamada, Koriyama, Fukushima 963-8052, Japan
| |
Collapse
|