1
|
Wilcox S, Huang Z, Shah J, Yang X, Chen Y. Respiration-Induced Organ Motion Compensation: A Review. Ann Biomed Eng 2025; 53:271-283. [PMID: 39384667 DOI: 10.1007/s10439-024-03630-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Accepted: 09/23/2024] [Indexed: 10/11/2024]
Abstract
PURPOSE Motion of organs in the abdominal and thoracic cavity caused by respiration is a major issue that affects a wide range of clinical diagnoses or treatment outcomes, including radiotherapy, high-intensity focused ultrasound ablation, and many generalized percutaneous needle interventions. These motions pose significant challenges in accurately reaching the target even for the experienced clinician. METHODS This review was conducted through comprehensive search on IEEE Explore, Google Scholar, and PubMed. RESULTS Diverse methods have been proposed to compensate for this motion effect to enable effective surgical operations. This review paper aims to examine the current respiratory motion compensation techniques used across the clinical procedures of radiotherapy, high-intensity focused ultrasound, and percutaneous needle procedures. CONCLUSION The complexity of respiratory-induced organ motion and diversity of areas for which compensation can be applied allows for a variety of methods to be implemented. This review aims to serve as inspiration for the future development of new systems to achieve clinical relevance.
Collapse
Affiliation(s)
- Samuel Wilcox
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Zhefeng Huang
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Jay Shah
- Department of Radiology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30329, USA
| | - Xiaofeng Yang
- Department of Radiation Oncology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30329, USA
| | - Yue Chen
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, 313 Ferst Dr STE 2127, Atlanta, GA, 30332, USA.
| |
Collapse
|
2
|
Cook EL, Su KH, Higgins GS, Johnsen R, Bouhnik JP, McGowan DR. Data-driven gating (DDG)-based motion match for improved CTAC registration. EJNMMI Phys 2024; 11:42. [PMID: 38691232 PMCID: PMC11554991 DOI: 10.1186/s40658-024-00644-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 04/24/2024] [Indexed: 05/03/2024] Open
Abstract
BACKGROUND Respiratory motion artefacts are a pitfall in thoracic PET/CT imaging. A source of these motion artefacts within PET images is the CT used for attenuation correction of the images. The arbitrary respiratory phase in which the helical CT ( CT helical ) is acquired often causes misregistration between PET and CT images, leading to inaccurate attenuation correction of the PET image. As a result, errors in tumour delineation or lesion uptake values can occur. To minimise the effect of motion in PET/CT imaging, a data-driven gating (DDG)-based motion match (MM) algorithm has been developed that estimates the phase of the CT helical , and subsequently warps this CT to a given phase of the respiratory cycle, allowing it to be phase-matched to the PET. A set of data was used which had four-dimensional CT (4DCT) acquired alongside PET/CT. The 4DCT allowed ground truth CT phases to be generated and compared to the algorithm-generated motion match CT (MMCT). Measurements of liver and lesion margin positions were taken across CT images to determine any differences and establish how well the algorithm performed concerning warping the CT helical to a given phase (end-of-expiration, EE). RESULTS Whilst there was a minor significance in the liver measurement between the 4DCT and MMCT ( p = 0.045 ), no significant differences were found between the 4DCT or MMCT for lesion measurements ( p = 1.0 ). In all instances, the CT helical was found to be significantly different from the 4DCT ( p < 0.001 ). Consequently, the 4DCT and MMCT can be considered equivalent with respect to warped CT generation, showing the DDG-based MM algorithm to be successful. CONCLUSION The MM algorithm successfully enables the phase-matching of a CT helical to the EE of a ground truth 4DCT. This would reduce the motion artefacts caused by PET/CT registration without requiring additional patient dose (required for a 4DCT).
Collapse
Affiliation(s)
- Ella L Cook
- Department of Oncology, University of Oxford, Oxford, UK
| | | | | | | | | | - Daniel R McGowan
- Department of Oncology, University of Oxford, Oxford, UK.
- Department of Medical Physics and Clinical Engineering, Oxford University Hospitals Foundation Trust, Oxford, UK.
| |
Collapse
|
3
|
Wise PA, Preukschas AA, Özmen E, Bellemann N, Norajitra T, Sommer CM, Stock C, Mehrabi A, Müller-Stich BP, Kenngott HG, Nickel F. Intraoperative liver deformation and organ motion caused by ventilation, laparotomy, and pneumoperitoneum in a porcine model for image-guided liver surgery. Surg Endosc 2024; 38:1379-1389. [PMID: 38148403 PMCID: PMC10881715 DOI: 10.1007/s00464-023-10612-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 11/26/2023] [Indexed: 12/28/2023]
Abstract
BACKGROUND Image-guidance promises to make complex situations in liver interventions safer. Clinical success is limited by intraoperative organ motion due to ventilation and surgical manipulation. The aim was to assess influence of different ventilatory and operative states on liver motion in an experimental model. METHODS Liver motion due to ventilation (expiration, middle, and full inspiration) and operative state (native, laparotomy, and pneumoperitoneum) was assessed in a live porcine model (n = 10). Computed tomography (CT)-scans were taken for each pig for each possible combination of factors. Liver motion was measured by the vectors between predefined landmarks along the hepatic vein tree between CT scans after image segmentation. RESULTS Liver position changed significantly with ventilation. Peripheral regions of the liver showed significantly higher motion (maximal Euclidean motion 17.9 ± 2.7 mm) than central regions (maximal Euclidean motion 12.6 ± 2.1 mm, p < 0.001) across all operative states. The total average motion measured 11.6 ± 0.7 mm (p < 0.001). Between the operative states, the position of the liver changed the most from native state to pneumoperitoneum (14.6 ± 0.9 mm, p < 0.001). From native state to laparotomy comparatively, the displacement averaged 9.8 ± 1.2 mm (p < 0.001). With pneumoperitoneum, the breath-dependent liver motion was significantly reduced when compared to other modalities. Liver motion due to ventilation was 7.7 ± 0.6 mm during pneumoperitoneum, 13.9 ± 1.1 mm with laparotomy, and 13.5 ± 1.4 mm in the native state (p < 0.001 in all cases). CONCLUSIONS Ventilation and application of pneumoperitoneum caused significant changes in liver position. Liver motion was reduced but clearly measurable during pneumoperitoneum. Intraoperative guidance/navigation systems should therefore account for ventilation and intraoperative changes of liver position and peripheral deformation.
Collapse
Affiliation(s)
- Philipp A Wise
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Anas A Preukschas
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany
| | - Emre Özmen
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Nadine Bellemann
- Department of Diagnostic and Interventional Radiology, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Tobias Norajitra
- Division of Medical and Biological Informatics, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Germany
| | - Christof M Sommer
- Department of Diagnostic and Interventional Radiology, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Christian Stock
- Institute for Medical Biometry and Informatics, Heidelberg University, Im Neuenheimer Feld 305, 69120, Heidelberg, Germany
| | - Arianeb Mehrabi
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Beat P Müller-Stich
- Division of Abdominal Surgery, Clarunis-Academic Centre of Gastrointestinal Diseases, St. Clara and University Hospital of Basel, Petersgraben 4, 4051, Basel, Switzerland
| | - Hannes G Kenngott
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany
| | - Felix Nickel
- Department of General, Visceral and Transplantation Surgery, Heidelberg University, Im Neuenheimer Feld 420, 69120, Heidelberg, Germany.
- Department of General, Visceral and Thoracic Surgery, University Medical Center Hamburg-Eppendorf, Martinistraße 52, 20246, Hamburg, Germany.
| |
Collapse
|
4
|
Terpstra ML, Maspero M, Verhoeff JJC, van den Berg CAT. Accelerated respiratory-resolved 4D-MRI with separable spatio-temporal neural networks. Med Phys 2023; 50:5331-5342. [PMID: 37527331 DOI: 10.1002/mp.16643] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 05/30/2023] [Accepted: 06/20/2023] [Indexed: 08/03/2023] Open
Abstract
BACKGROUND Respiratory-resolved four-dimensional magnetic resonance imaging (4D-MRI) provides essential motion information for accurate radiation treatments of mobile tumors. However, obtaining high-quality 4D-MRI suffers from long acquisition and reconstruction times. PURPOSE To develop a deep learning architecture to quickly acquire and reconstruct high-quality 4D-MRI, enabling accurate motion quantification for MRI-guided radiotherapy (MRIgRT). METHODS A small convolutional neural network called MODEST is proposed to reconstruct 4D-MRI by performing a spatial and temporal decomposition, omitting the need for 4D convolutions to use all the spatio-temporal information present in 4D-MRI. This network is trained on undersampled 4D-MRI after respiratory binning to reconstruct high-quality 4D-MRI obtained by compressed sensing reconstruction. The network is trained, validated, and tested on 4D-MRI of 28 lung cancer patients acquired with a T1-weighted golden-angle radial stack-of-stars (GA-SOS) sequence. The 4D-MRI of 18, 5, and 5 patients were used for training, validation, and testing. Network performances are evaluated on image quality measured by the structural similarity index (SSIM) and motion consistency by comparing the position of the lung-liver interface on undersampled 4D-MRI before and after respiratory binning. The network is compared to conventional architectures such as a U-Net, which has 30 times more trainable parameters. RESULTS MODEST can reconstruct high-quality 4D-MRI with higher image quality than a U-Net, despite a thirty-fold reduction in trainable parameters. High-quality 4D-MRI can be obtained using MODEST in approximately 2.5 min, including acquisition, processing, and reconstruction. CONCLUSION High-quality accelerated 4D-MRI can be obtained using MODEST, which is particularly interesting for MRIgRT.
Collapse
Affiliation(s)
- Maarten L Terpstra
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Matteo Maspero
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Joost J C Verhoeff
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Cornelis A T van den Berg
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Diagnostics & Therapy, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
5
|
Gilani N, Mikheev A, Brinkmann IM, Basukala D, Benkert T, Kumbella M, Babb JS, Chandarana H, Sigmund EE. Characterization of motion dependent magnetic field inhomogeneity for DWI in the kidneys. Magn Reson Imaging 2023; 100:93-101. [PMID: 36924807 PMCID: PMC10108090 DOI: 10.1016/j.mri.2023.03.008] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/10/2023] [Accepted: 03/12/2023] [Indexed: 03/15/2023]
Abstract
PURPOSE Diffusion-weighted imaging (DWI) of the abdomen has increased dramatically for both research and clinical purposes. Motion and static field inhomogeneity related challenges limit image quality of abdominopelvic imaging with the most conventional echo-planar imaging (EPI) pulse sequence. While reversed phase encoded imaging is increasingly used to facilitate distortion correction, it typically assumes one motion independent magnetic field distribution. In this study, we describe a more generalized workflow for the case of kidney DWI in which the field inhomogeneity at multiple respiratory phases is mapped and used to correct all images in a multi-contrast DWI series. METHODS In this HIPAA-compliant and IRB-approved prospective study, 8 volunteers (6 M, ages 28-51) had abdominal imaging performed in a 3 T MRI system (MAGNETOM Prisma; Siemens Healthcare, Erlangen, Germany) with ECG gating. Coronal oblique T2-weighted HASTE images were collected for anatomical reference. Sagittal phase-contrast (PC) MRI images through the left renal artery were collected to determine systolic and diastolic phases. Cardiac triggered oblique coronal DWI were collected at 10 b-values between 0 and 800 s/mm2 and 12 directions. DWI series were distortion corrected using field maps generated by forward and reversed phase encoded b = 0 images collected over the full respiratory cycle and matched by respiratory phase. Morphologic accuracy, intraseries spatial variability, and diffusion tensor imaging (DTI) metrics mean diffusivity (MD) and fractional anisotropy (FA) were compared for results generated with no distortion correction, correction with only one respiratory bin, and correction with multiple respiratory bins across the breathing cycle. RESULTS Computed field maps showed significant variation in static field with kidney laterality, region, and respiratory phase. Distortion corrected images showed significantly better registration to morphologic images than uncorrected images; for the left kidney, the multiple bin correction outperformed one bin correction. Line profile analysis showed significantly reduced spatial variation with multiple bins than one bin correction. DTI metrics were mostly similar between correction methods, with some differences observed in MD between uncorrected and corrected datasets. CONCLUSIONS Our results indicate improved morphology of kidney DWI and derived parametric maps as well as reduced variability over the full image series using the motion-resolved distortion correction. This work highlights some morphologic and quantitative metric improvements can be obtained for kidney DWI when distortion correction is performed in a respiratory-resolved manner.
Collapse
Affiliation(s)
- Nima Gilani
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA.
| | - Artem Mikheev
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | | | - Dibash Basukala
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | | | - Malika Kumbella
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - James S Babb
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - Hersh Chandarana
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA
| | - Eric E Sigmund
- Center for Advanced Imaging and Innovation (CAI(2)R), Center for Biomedical Imaging, Department of Radiology, NYU Langone Health, New York, USA.
| |
Collapse
|
6
|
Gunderman A, Montayre R, Ranjan A, Chen Y. Review of Robot-Assisted HIFU Therapy. SENSORS (BASEL, SWITZERLAND) 2023; 23:3707. [PMID: 37050766 PMCID: PMC10098661 DOI: 10.3390/s23073707] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Revised: 03/07/2023] [Accepted: 03/14/2023] [Indexed: 06/19/2023]
Abstract
This paper provides an overview of current robot-assisted high-intensity focused ultrasound (HIFU) systems for image-guided therapies. HIFU is a minimally invasive technique that relies on the thermo-mechanical effects of focused ultrasound waves to perform clinical treatments, such as tumor ablation, mild hyperthermia adjuvant to radiation or chemotherapy, vein occlusion, and many others. HIFU is typically performed under ultrasound (USgHIFU) or magnetic resonance imaging guidance (MRgHIFU), which provide intra-operative monitoring of treatment outcomes. Robot-assisted HIFU probe manipulation provides precise HIFU focal control to avoid damage to surrounding sensitive anatomy, such as blood vessels, nerve bundles, or adjacent organs. These clinical and technical benefits have promoted the rapid adoption of robot-assisted HIFU in the past several decades. This paper aims to present the recent developments of robot-assisted HIFU by summarizing the key features and clinical applications of each system. The paper concludes with a comparison and discussion of future perspectives on robot-assisted HIFU.
Collapse
Affiliation(s)
- Anthony Gunderman
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Rudy Montayre
- Department of Physiological Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK 74078, USA
| | - Ashish Ranjan
- Department of Physiological Sciences, College of Veterinary Medicine, Oklahoma State University, Stillwater, OK 74078, USA
| | - Yue Chen
- Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| |
Collapse
|
7
|
Jassar H, Tai A, Chen X, Keiper TD, Paulson E, Lathuilière F, Bériault S, Hébert F, Savard L, Cooper DT, Cloake S, Li XA. Real-time motion monitoring using orthogonal cine MRI during MR-guided adaptive radiation therapy for abdominal tumors on 1.5T MR-Linac. Med Phys 2023; 50:3103-3116. [PMID: 36893292 DOI: 10.1002/mp.16342] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2022] [Revised: 02/01/2023] [Accepted: 02/24/2023] [Indexed: 03/11/2023] Open
Abstract
BACKGROUND Real-time motion monitoring (RTMM) is necessary for accurate motion management of intrafraction motions during radiation therapy (RT). PURPOSE Building upon a previous study, this work develops and tests an improved RTMM technique based on real-time orthogonal cine magnetic resonance imaging (MRI) acquired during magnetic resonance-guided adaptive RT (MRgART) for abdominal tumors on MR-Linac. METHODS A motion monitoring research package (MMRP) was developed and tested for RTMM based on template rigid registration between beam-on real-time orthogonal cine MRI and pre-beam daily reference 3D-MRI (baseline). The MRI data acquired under free-breathing during the routine MRgART on a 1.5T MR-Linac for 18 patients with abdominal malignancies of 8 liver, 4 adrenal glands (renal fossa), and 6 pancreas cases were used to evaluate the MMRP package. For each patient, a 3D mid-position image derived from an in-house daily 4D-MRI was used to define a target mask or a surrogate sub-region encompassing the target. Additionally, an exploratory case reviewed for an MRI dataset of a healthy volunteer acquired under both free-breathing and deep inspiration breath-hold (DIBH) was used to test how effectively the RTMM using the MMRP can address through-plane motion (TPM). For all cases, the 2D T2/T1-weighted cine MRIs were captured with a temporal resolution of 200 ms interleaved between coronal and sagittal orientations. Manually delineated contours on the cine frames were used as the ground-truth motion. Common visible vessels and segments of target boundaries in proximity to the target were used as anatomical landmarks for reproducible delineations on both the 3D and the cine MRI images. Standard deviation of the error (SDE) between the ground-truth and the measured target motion from the MMRP package were analyzed to evaluate the RTMM accuracy. The maximum target motion (MTM) was measured on the 4D-MRI for all cases during free-breathing. RESULTS The mean (range) centroid motions for the 13 abdominal tumor cases were 7.69 (4.71-11.15), 1.73 (0.81-3.05), and 2.71 (1.45-3.93) mm with an overall accuracy of <2 mm in the superior-inferior (SI), the left-right (LR), and the anterior-posterior (AP) directions, respectively. The mean (range) of the MTM from the 4D-MRI was 7.38 (2-11) mm in the SI direction, smaller than the monitored motion of centroid, demonstrating the importance of the real-time motion capture. For the remaining patient cases, the ground-truth delineation was challenging under free-breathing due to the target deformation and the large TPM in the AP direction, the implant-induced image artifacts, and/or the suboptimal image plane selection. These cases were evaluated based on visual assessment. For the healthy volunteer, the TPM of the target was significant under free-breathing which degraded the RTMM accuracy. RTMM accuracy of <2 mm was achieved under DIBH, indicating DIBH is an effective method to address large TPM. CONCLUSIONS We have successfully developed and tested the use of a template-based registration method for an accurate RTMM of abdominal targets during MRgART on a 1.5T MR-Linac without using injected contrast agents or radio-opaque implants. DIBH may be used to effectively reduce or eliminate TPM of abdominal targets during RTMM.
Collapse
Affiliation(s)
- Hassan Jassar
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - An Tai
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Xinfeng Chen
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Timothy D Keiper
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Eric Paulson
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | | | | | | | | | | | | | - X Allen Li
- Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| |
Collapse
|
8
|
Shahbaz M, Miao H, Farhaj Z, Gong X, Weikai S, Dong W, Jun N, Shuwei L, Yu D. Mixed reality navigation training system for liver surgery based on a high-definition human cross-sectional anatomy data set. Cancer Med 2023; 12:7992-8004. [PMID: 36607128 PMCID: PMC10134360 DOI: 10.1002/cam4.5583] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 11/24/2022] [Accepted: 12/17/2022] [Indexed: 01/07/2023] Open
Abstract
OBJECTIVES This study aims to use the three-dimensional (3D) mixed-reality model of liver, entailing complex intrahepatic systems and to deeply study the anatomical structures and to promote the training, diagnosis and treatment of liver diseases. METHODS Vascular perfusion human specimens were used for thin-layer frozen milling to obtain liver cross-sections. The 104-megapixel-high-definition cross sectional data set was established and registered to achieve structure identification and manual segmentation. The digital model was reconstructed and data was used to print a 3D hepatic model. The model was combined with HoloLens mixed reality technology to reflect the complex relationships of intrahepatic systems. We simulated 3D patient specific anatomy for identification and preoperative planning, conducted a questionnaire survey, and evaluated the results. RESULTS The 3D digital model and 1:1 transparent and colored model of liver established truly reflected intrahepatic vessels and their complex relationships. The reconstructed model imported into HoloLens could be accurately matched with the 3D model. Only 7.7% participants could identify accessory hepatic veins. The depth and spatial-relationship of intrahepatic structures were better understandable for 92%. The 100%, 84.6%, 69% and 84% believed the 3D models were useful in planning, safer surgical paths, reducing intraoperative complications and training of young surgeons respectively. CONCLUSIONS A detailed 3D model can be reconstructed using the higher quality cross-sectional anatomical data set. When combined with 3D printing and HoloLens technology, a novel hybrid-reality navigation-training system for liver surgery is created. Mixed Reality training is a worthy alternative to provide 3D information to clinicians and its possible application in surgery. This conclusion was obtained based on a questionnaire and evaluation. Surgeons with extensive experience in surgical operations perceived in the questionnaire that this technology might be useful in liver surgery, would help in precise preoperative planning, accurate intraoperative identification, and reduction of hepatic injury.
Collapse
Affiliation(s)
- Muhammad Shahbaz
- Department of Radiology, Qilu Hospital of Shandong UniversityJinanShandongChina
- Research Center for Sectional and Imaging AnatomyDigital Human Institute, School of Basic Medical Science, Shandong UniversityJinanShandongChina
- Department of General SurgeryQilu Hospital of Shandong UniversityJinanShandongChina
| | - Huachun Miao
- Department of Anatomy, Wannan Medical CollegeWuhuAnhuiChina
| | - Zeeshan Farhaj
- Department of Cardiovascular Surgery, Shandong Qianfoshan Hospital, Cheeloo College of MedicineShandong UniversityJinanShandongChina
| | - Xin Gong
- Department of Anatomy, Wannan Medical CollegeWuhuAnhuiChina
| | - Sun Weikai
- Department of Radiology, Qilu Hospital of Shandong UniversityJinanShandongChina
| | - Wenqing Dong
- Department of Anatomy, Wannan Medical CollegeWuhuAnhuiChina
| | - Niu Jun
- Department of General SurgeryQilu Hospital of Shandong UniversityJinanShandongChina
| | - Liu Shuwei
- Research Center for Sectional and Imaging AnatomyDigital Human Institute, School of Basic Medical Science, Shandong UniversityJinanShandongChina
| | - Dexin Yu
- Department of Radiology, Qilu Hospital of Shandong UniversityJinanShandongChina
| |
Collapse
|
9
|
Jeong S, Cheon W, Cho S, Han Y. Clinical applicability of deep learning-based respiratory signal prediction models for four-dimensional radiation therapy. PLoS One 2022; 17:e0275719. [PMID: 36256632 PMCID: PMC9578620 DOI: 10.1371/journal.pone.0275719] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 09/21/2022] [Indexed: 11/07/2022] Open
Abstract
For accurate respiration gated radiation therapy, compensation for the beam latency of the beam control system is necessary. Therefore, we evaluate deep learning models for predicting patient respiration signals and investigate their clinical feasibility. Herein, long short-term memory (LSTM), bidirectional LSTM (Bi-LSTM), and the Transformer are evaluated. Among the 540 respiration signals, 60 signals are used as test data. Each of the remaining 480 signals was spilt into training and validation data in a 7:3 ratio. A total of 1000 ms of the signal sequence (Ts) is entered to the models, and the signal at 500 ms afterward (Pt) is predicted (standard training condition). The accuracy measures are: (1) root mean square error (RMSE) and Pearson correlation coefficient (CC), (2) accuracy dependency on Ts and Pt, (3) respiratory pattern dependency, and (4) error for 30% and 70% of the respiration gating for a 5 mm tumor motion for latencies of 300, 500, and 700 ms. Under standard conditions, the Transformer model exhibits the highest accuracy with an RMSE and CC of 0.1554 and 0.9768, respectively. An increase in Ts improves accuracy, whereas an increase in Pt decreases accuracy. An evaluation of the regularity of the respiratory signals reveals that the lowest predictive accuracy is achieved with irregular amplitude patterns. For 30% and 70% of the phases, the average error of the three models is <1.4 mm for a latency of 500 ms and >2.0 mm for a latency of 700 ms. The prediction accuracy of the Transformer is superior to LSTM and Bi-LSTM. Thus, the three models have clinically applicable accuracies for a latency <500 ms for 10 mm of regular tumor motion. The clinical acceptability of the deep learning models depends on the inherent latency and the strategy for reducing the irregularity of respiration.
Collapse
Affiliation(s)
- Sangwoon Jeong
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
| | - Wonjoong Cheon
- Proton Therapy Center, National Cancer Center, Goyang, Korea
| | - Sungkoo Cho
- Department of Radiation Oncology, Samsung Medical Center, Seoul, Korea
| | - Youngyih Han
- Department of Health Sciences and Technology, SAIHST, Sungkyunkwan University, Seoul, Korea
- Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- * E-mail:
| |
Collapse
|
10
|
Burkoň P, Trna J, Slávik M, Němeček R, Kazda T, Pospíšil P, Dastych M, Eid M, Novotný I, Procházka T, Vrzal M. Stereotactic Body Radiotherapy (SBRT) of Pancreatic Cancer-A Critical Review and Practical Consideration. Biomedicines 2022; 10:biomedicines10102480. [PMID: 36289742 PMCID: PMC9599229 DOI: 10.3390/biomedicines10102480] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/18/2022] [Accepted: 09/30/2022] [Indexed: 11/23/2022] Open
Abstract
Pancreatic cancer is the third leading cause of cancer death in the developed world and is predicted to become the second by 2030. A cure may be achieved only with surgical resection of an early diagnosed disease. Surgery for more advanced disease is challenging and can be contraindicated for many reasons. Neoadjuvant therapy may improve the probability of achieving R0 resection. It consists of systemic treatment followed by radiation therapy applied concurrently or sequentially with cytostatics. A novel approach to irradiation, stereotactic body radiotherapy (SBRT), has the potential to improve treatment results. SBRT can deliver higher doses of radiation to the tumor in only a few treatment fractions. It has attracted significant interest for pancreatic cancer patients, as it is completed quickly, requires less time away from full-dose chemotherapy, and is well-tolerated than conventional radiotherapy. In this review, we aim to provide the reader with a basic overview of current evidence for SBRT indications in the treatment of pancreatic tumors. In the second part of the review, we focus on practical information with respect to SBRT treatment plan preparation the performance of such therapy. Finally, we discuss future directions related to the use of magnetic resonance linear accelerators.
Collapse
Affiliation(s)
- Petr Burkoň
- Department of Radiation Oncology, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 57 Brno, Czech Republic
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
| | - Jan Trna
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
- Department of Gastroenterology and Digestive Endoscopy, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 53 Brno, Czech Republic
- Department of Comprehensive Cancer Care, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 53 Brno, Czech Republic
- Correspondence: (J.T.); (M.S.)
| | - Marek Slávik
- Department of Radiation Oncology, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 57 Brno, Czech Republic
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
- Correspondence: (J.T.); (M.S.)
| | - Radim Němeček
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
- Department of Comprehensive Cancer Care, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 53 Brno, Czech Republic
| | - Tomáš Kazda
- Department of Radiation Oncology, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 57 Brno, Czech Republic
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
| | - Petr Pospíšil
- Department of Radiation Oncology, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 57 Brno, Czech Republic
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
| | - Milan Dastych
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
- Department of Gastroenterology, University Hospital Brno, Jihlavska 340/20, 625 00 Brno, Czech Republic
| | - Michal Eid
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
- Department of Hematology, Oncology and Internal Medicine, University Hospital Brno, Jihlavska 340/20, 625 00 Brno, Czech Republic
| | - Ivo Novotný
- Department of Gastroenterology and Digestive Endoscopy, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 53 Brno, Czech Republic
| | - Tomáš Procházka
- Department of Radiation Oncology, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 57 Brno, Czech Republic
- Faculty of Medicine, Masaryk University, Kamenice 753/5, 625 00 Brno, Czech Republic
| | - Miroslav Vrzal
- Department of Radiation Oncology, Masaryk Memorial Cancer Institute, Zluty Kopec 7, 656 57 Brno, Czech Republic
| |
Collapse
|
11
|
Ji T, Feng Z, Sun E, Ng SK, Su L, Zhang Y, Han D, Han-Oh S, Iordachita I, Lee J, Kazanzides P, Bell MAL, Wong J, Ding K. A phantom-based analysis for tracking intra-fraction pancreatic tumor motion by ultrasound imaging during radiation therapy. Front Oncol 2022; 12:996537. [PMID: 36237341 PMCID: PMC9552199 DOI: 10.3389/fonc.2022.996537] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Accepted: 09/07/2022] [Indexed: 11/13/2022] Open
Abstract
PurposeIn this study, we aim to further evaluate the accuracy of ultrasound tracking for intra-fraction pancreatic tumor motion during radiotherapy by a phantom-based study.MethodsTwelve patients with pancreatic cancer who were treated with stereotactic body radiation therapy were enrolled in this study. The displacement points of the respiratory cycle were acquired from 4DCT and transferred to a motion platform to mimic realistic breathing movements in our phantom study. An ultrasound abdominal phantom was placed and fixed in the motion platform. The ground truth of phantom movement was recorded by tracking an optical tracker attached to this phantom. One tumor inside the phantom was the tracking target. In the evaluation of the results, the monitoring results from the ultrasound system were compared with the phantom motion results from the infrared camera. Differences between infrared monitoring motion and ultrasound tracking motion were analyzed by calculating the root-mean-square error.ResultsThe 82.2% ultrasound tracking motion was within a 0.5 mm difference value between ultrasound tracking displacement and infrared monitoring motion. 0.7% ultrasound tracking failed to track accurately (a difference value > 2.5 mm). These differences between ultrasound tracking motion and infrared monitored motion do not correlate with respiratory displacements, respiratory velocity, or respiratory acceleration by linear regression analysis.ConclusionsThe highly accurate monitoring results of this phantom study prove that the ultrasound tracking system may be a potential method for real-time monitoring targets, allowing more accurate delivery of radiation doses.
Collapse
Affiliation(s)
- Tianlong Ji
- Department of Radiation Oncology, The First Hospital of China Medical University, Shenyang, China
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Ziwei Feng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - Edward Sun
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Sook Kien Ng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Lin Su
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Yin Zhang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Dong Han
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Sarah Han-Oh
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Iulian Iordachita
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - Junghoon Lee
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Peter Kazanzides
- Department of Computer Science, Johns Hopkins University, Baltimore, MD, United States
| | - Muyinatu A. Lediju Bell
- Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, United States
| | - John Wong
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
| | - Kai Ding
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins School of Medicine, Baltimore, MD, United States
- *Correspondence: Kai Ding,
| |
Collapse
|
12
|
Grimbergen G, Eijkelenkamp H, Heerkens HD, Raaymakers BW, Intven MPW, Meijer GJ. Dosimetric impact of intrafraction motion under abdominal compression during MR-guided SBRT for (Peri-) pancreatic tumors. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac8ddd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 08/30/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. Intrafraction motion is a major concern for the safety and effectiveness of high dose stereotactic body radiotherapy (SBRT) in the upper abdomen. In this study, the impact of the intrafraction motion on the delivered dose was assessed in a patient group that underwent MR-guided radiotherapy for upper abdominal malignancies with an abdominal corset. Approach. Fast online 2D cine MRI was used to extract tumor motion during beam-on time. These tumor motion profiles were combined with linac log files to reconstruct the delivered dose in 89 fractions of MR-guided SBRT in twenty patients. Aside the measured tumor motion, motion profiles were also simulated for a wide range of respiratory amplitudes and drifts, and their subsequent dosimetric impact was calculated in every fraction. Main results. The average (SD) D
99% of the gross tumor volume (GTV), relative to the planned D
99%, was 0.98 (0.03). The average (SD) relative D
0.5cc
of the duodenum, small bowel and stomach was 0.99 (0.03), 1.00 (0.03), and 0.97 (0.05), respectively. No correlation of respiratory amplitude with dosimetric impact was observed. Fractions with larger baseline drifts generally led to a larger uncertainty of dosimetric impact on the GTV and organs at risk (OAR). The simulations yielded that the delivered dose is highly dependent on the direction of on baseline drift. Especially in anatomies where the OARs are closely abutting the GTV, even modest LR or AP drifts can lead to substantial deviations from the planned dose. Significance. The vast majority of the fractions was only modestly impacted by intrafraction motion, increasing our confidence that MR-guided SBRT with abdominal compression can be safely executed for patients with abdominal tumors, without the use of gating or tracking strategies.
Collapse
|
13
|
Zeng C, Lu W, Reyngold M, Cuaron JJ, Li X, Cerviño L, Li T. Intrafractional accuracy and efficiency of a surface imaging system for deep inspiration breath hold during ablative gastrointestinal cancer treatment. J Appl Clin Med Phys 2022; 23:e13740. [PMID: 35906884 PMCID: PMC9680575 DOI: 10.1002/acm2.13740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 07/18/2022] [Accepted: 07/15/2022] [Indexed: 01/19/2023] Open
Abstract
PURPOSE Beam gating with deep inspiration breath hold (DIBH) usually depends on some external surrogate to infer internal target movement, and the exact internal movement is unknown. In this study, we tracked internal targets and characterized residual motion during DIBH treatment, guided by a surface imaging system, for gastrointestinal cancer. We also report statistics on treatment time. METHODS AND MATERIALS We included 14 gastrointestinal cancer patients treated with surface imaging-guided DIBH volumetrically modulated arc therapy, each with at least one radiopaque marker implanted near or within the target. They were treated in 25, 15, or 10 fractions. Thirteen patients received treatment for pancreatic cancer, and one underwent separate treatments for two liver metastases. The surface imaging system monitored a three-dimensional surface with ± 3 mm translation and ± 3° rotation threshold. During delivery, a kilovolt image was automatically taken every 20° or 40° gantry rotation, and the internal marker was identified from the image. The displacement and residual motion of the markers were calculated. To analyze the treatment efficiency, the treatment time of each fraction was obtained from the imaging and treatment timestamps in the record and verify system. RESULTS Although the external surface was monitored and limited to ± 3 mm and ± 3°, significant residual internal target movement was observed in some patients. The range of residual motion was 3-21 mm. The average displacement for this cohort was 0-3 mm. In 19% of the analyzed images, the magnitude of the instantaneous displacement was > 5 mm. The mean treatment time was 17 min with a standard deviation of 4 min. CONCLUSIONS Precaution is needed when applying surface image guidance for gastrointestinal cancer treatment. Using it as a solo DIBH technique is discouraged when the correlation between internal anatomy and patient surface is limited. Real-time radiographic verification is critical for safe treatments.
Collapse
Affiliation(s)
- Chuan Zeng
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Wei Lu
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Marsha Reyngold
- Department of Radiation OncologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - John J. Cuaron
- Department of Radiation OncologyMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Xiang Li
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Laura Cerviño
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| | - Tianfang Li
- Department of Medical PhysicsMemorial Sloan Kettering Cancer CenterNew YorkNew YorkUSA
| |
Collapse
|
14
|
Musa M, Sengupta S, Chen Y. Design of a 6-DoF Parallel Robotic Platform for MRI Applications. JOURNAL OF MEDICAL ROBOTICS RESEARCH 2022; 7:2241005. [PMID: 37614779 PMCID: PMC10445425 DOI: 10.1142/s2424905x22410057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
In this work, the design, analysis, and characterization of a parallel robotic motion generation platform with 6-degrees of freedom (DoF) for magnetic resonance imaging (MRI) applications are presented. The motivation for the development of this robot is the need for a robotic platform able to produce accurate 6-DoF motion inside the MRI bore to serve as the ground truth for motion modeling; other applications include manipulation of interventional tools such as biopsy and ablation needles and ultrasound probes for therapy and neuromodulation under MRI guidance. The robot is comprised of six pneumatic cylinder actuators controlled via a robust sliding mode controller. Tracking experiments of the pneumatic actuator indicates that the system is able to achieve an average error of 0.69 ± 0.14 mm and 0.67 ± 0.40 mm for step signal tracking and sinusoidal signal tracking, respectively. To demonstrate the feasibility and potential of using the proposed robot for minimally invasive procedures, a phantom experiment was performed in the benchtop environment, which showed a mean positional error of 1.20 ± 0.43 mm and a mean orientational error of 1.09 ± 0.57°, respectively. Experiments conducted in a 3T whole body human MRI scanner indicate that the robot is MRI compatible and capable of achieving positional error of 1.68 ± 0.31 mm and orientational error of 1.51 ± 0.32° inside the scanner, respectively. This study demonstrates the potential of this device to enable accurate 6-DoF motions in the MRI environment.
Collapse
Affiliation(s)
- Mishek Musa
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR 72701, USA
| | - Saikat Sengupta
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Yue Chen
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta, GA 30332, USA
| |
Collapse
|
15
|
Musa MJ, Sharma K, Cleary K, Chen Y. Respiratory Compensated Robot for Liver Cancer Treatment: Design, Fabrication, and Benchtop Characterization. IEEE/ASME TRANSACTIONS ON MECHATRONICS 2022; 27:268-279. [DOI: 10.1109/tmech.2021.3062984] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
16
|
Sun JC, Hsieh BT, Hsieh CM, Tsang YW, Cheng KY. Applying the N-isopropylacrylamide gel dosimeter to quantify dynamic dose effects: A feasibility study. Technol Health Care 2022; 30:413-424. [PMID: 35124616 PMCID: PMC9028750 DOI: 10.3233/thc-thc228038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND: The gel dosimeter is a chemical as well as a relative dosimeter. OBJECTIVE: To evaluate the feasibility of using N-isopropylacrylamide (NIPAM) gel dosimeter to observe the dynamic dose effects and quantification of the respiration, and to help determine the safety margins. METHODS: The NIPAM gel dosimeter combined with the dynamic phantom was used to simulate radiotherapy of lung or upper abdominal tumor. The field set to 4 × 5 cm2, simulate respiratory rate of 4 sec/cycle, and motion range 2 cm. MRI was used for reading, and MATLAB was used for analysis. The 3%/3 mm gamma passing rate > 95% was used as a clinical basis for evaluation. RESULTS: The dynamic dose curve was compared with 4 × 5, 4 × 4, 4 × 3 cm2 TPS, and gamma passing rates were 74.32%, 54.83%, 30.18%. Gamma mapping demonstrated that the highest dose region was similar to the result of the 4 × 4 cm2 TPS. After appropriate selection and comparing that the ⩾ 60% part of the dose curve with TPS, the gamma passing rate was 96.49%. CONCLUSIONS: Using the NIPAM gel dosimeter with dynamic phantom to simulate organ motion during respiration for dynamic dose measurement and quantified the dynamic dose effect is feasible. The results are consistent with clinical evaluation standards.
Collapse
Affiliation(s)
- Jung-Chang Sun
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Bor-Tsung Hsieh
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Chih-Ming Hsieh
- Department of Medical Imaging, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
| | - Yuk-Wah Tsang
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Biomedical Engineering, Chung Yuan Christian University, Taoyuan, Taiwan
| | - Kai-Yuan Cheng
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| |
Collapse
|
17
|
Sun JC, Hsieh BT, Cheng CW, Hsieh CM, Tsang YW, Cheng KY. Using NIPAM gel dosimeter and concentric swing machine to simulate the dose distribution during breathing: A feasibility study. Technol Health Care 2022; 30:123-133. [PMID: 35124590 PMCID: PMC9028686 DOI: 10.3233/thc-228012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND: Radiotherapy plays an important role in cancer treatment today. Successful radiotherapy includes precise positioning and accurate dosimetry. OBJECTIVE: To use NIPAM gel dosimeter and concentric swing machine to simulate and evaluate the feasibility of lung or upper abdominal tumor dose distribution during breathing. METHODS: We used a concentric swing machine to simulate actual radiotherapy for lung or upper abdomen tumors. A 4 × 4 cm2 irradiation field area was set and MRI was performed. Next, readout analysis was performed using MATLAB and the 3 mm, 3% gamma passing rate > 95% was used as a basis for evaluation. RESULTS: The concentric dynamic dose curve for a simulated respiratory rate of 3 seconds/breath and 4 × 4 cm2 field was compared with 4 × 4, 3 × 3, and 2 × 2 cm2 treatment planning systems (TPS), and the 3 mm, 3% gamma passing rate was 42.87%, 54.96%, and 49.92%, respectively. Pre-simulation showed that the high-dose region dose curve was similar to the 2 × 2 cm2 TPS result. After appropriate selection and comparison, we found that the 3 mm, 3% gamma passing rate was 97.92% on comparing the > 60% dose curve with the 2 × 2 cm2 TPS. CONCLUSIONS: NIPAM gel dosimeter and concentric swing machine use is feasible to simulate dose distribution during breathing and results conforming to clinical evaluation standards.
Collapse
Affiliation(s)
- Jung-Chang Sun
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Bor-Tsung Hsieh
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| | - Chih-Wu Cheng
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
| | - Chih-Ming Hsieh
- Department of Medical Imaging, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
| | - Yuk-Wah Tsang
- Department of Radiation Oncology, Ditmanson Medical Foundation Chia-Yi Christian Hospital, Chiayi, Taiwan
- Department of Biomedical Engineering, Chung Yuan Christian University, Taoyuan, Taiwan
| | - Kai-Yuan Cheng
- Department of Medical Imaging and Radiological Sciences, Central Taiwan University of Science and Technology, Taichung, Taiwan
| |
Collapse
|
18
|
Grimbergen G, Eijkelenkamp H, Heerkens HD, Raaymakers BW, Intven MPW, Meijer GJ. Intrafraction pancreatic tumor motion patterns during ungated magnetic resonance guided radiotherapy with an abdominal corset. Phys Imaging Radiat Oncol 2022; 21:1-5. [PMID: 35005257 PMCID: PMC8715205 DOI: 10.1016/j.phro.2021.12.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2021] [Revised: 12/07/2021] [Accepted: 12/10/2021] [Indexed: 12/25/2022] Open
Abstract
Background Stereotactic body radiotherapy (SBRT) has been shown to be a promising therapy for unresectable pancreatic tumors. However, intrafraction motion, caused by respiratory motion and organ drift, is one of the main concerns for efficient dose delivery in ungated upper abdominal radiotherapy. The aim of this study was to analyze the intrafraction gross tumor volume (GTV) motion in a clinical cohort. Materials and methods We included 13 patients that underwent online adaptive magnetic resonance (MR)-guided SBRT for malignancies in the pancreatic region (5 × 8 Gy). An abdominal corset was fitted in order to reduce the abdominal respiratory motion. Coronal and sagittal cine magnetic resonance images of the tumor region were made at 2 Hz during the entire beam-on time of each fraction. We used deformable image registration to obtain GTV motion profiles in all three directions, which were subsequently high-pass and low-pass filtered to isolate the motion caused by respiratory motion and baseline drift, respectively. Results The mean (SD) respiratory amplitudes were 4.2 (1.9) mm cranio-caudal (CC), 2.3 (1.1) mm ventral-dorsal (AP) and 1.4 (0.6) mm left–right (LR), with low variability within patients. The mean (SD) maximum baseline drifts were 1.2 (1.1) mm CC, 0.5 (0.4) mm AP and 0.5 (0.3) mm LR. The mean (SD) minimum baseline drifts were −0.7 (0.5) mm CC, −0.6 (0.5) mm AP and −0.5 (0.4) mm LR. Conclusion Overall tumor motion during treatment was small and interfractionally stable. These findings show that high-precision ungated MR-guided SBRT is feasible with an abdominal corset.
Collapse
Affiliation(s)
- Guus Grimbergen
- Department of Radiation Oncology, University Medical Center Utrecht, the Netherlands
| | - Hidde Eijkelenkamp
- Department of Radiation Oncology, University Medical Center Utrecht, the Netherlands
| | - Hanne D Heerkens
- Department of Radiation Oncology, University Medical Center Utrecht, the Netherlands
| | - Bas W Raaymakers
- Department of Radiation Oncology, University Medical Center Utrecht, the Netherlands
| | - Martijn P W Intven
- Department of Radiation Oncology, University Medical Center Utrecht, the Netherlands
| | - Gert J Meijer
- Department of Radiation Oncology, University Medical Center Utrecht, the Netherlands
| |
Collapse
|
19
|
Audière S, Labourdette A, Miette V, Fournier C, Ternifi R, Boussida S, Pouletaut P, Charleux F, Bensamoun SF, Harrison SA, Sandrin L. Improved Ultrasound Attenuation Measurement Method for the Non-invasive Evaluation of Hepatic Steatosis Using FibroScan. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:3181-3195. [PMID: 34373137 DOI: 10.1016/j.ultrasmedbio.2021.07.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/24/2021] [Accepted: 07/13/2021] [Indexed: 06/13/2023]
Abstract
Controlled attenuation parameter (CAP) is a measurement of ultrasound attenuation used to assess liver steatosis non-invasively. However, the standard method has some limitations. This study assessed the performance of a new CAP method by ex vivo and in vivo assessments. The major difference with the new method is that it uses ultrasound data continuously acquired during the imaging phase of the FibroScan examination. Seven reference tissue-mimicking phantoms were used to test the performance. In vivo performance was assessed in two cohorts (in total 195 patients) of patients using magnetic resonance imaging proton density fat fraction (MRI-PDFF) as a reference. The precision of CAP was improved by more than 50% on tissue-mimicking phantoms and 22%-41% in the in vivo cohort studies. The agreement between both methods was excellent, and the correlation between CAP and MRI-PDFF improved in both studies (0.71 to 0.74; 0.70 to 0.76). Using MRI-PDFF as a reference, the diagnostic performance of the new method was at least equal or superior (area under the receiver operating curve 0.889-0.900, 0.835-0.873). This study suggests that the new continuous CAP method can significantly improve the precision of CAP measurements ex vivo and in vivo.
Collapse
Affiliation(s)
| | | | | | | | - Redouane Ternifi
- Université de technologie de Compiègne, CNRS, Biomechanics and Bioengineering, Centre de recherche Royallieu, Compiègne, France
| | - Salem Boussida
- Université de technologie de Compiègne, CNRS, Biomechanics and Bioengineering, Centre de recherche Royallieu, Compiègne, France
| | - Philippe Pouletaut
- Université de technologie de Compiègne, CNRS, Biomechanics and Bioengineering, Centre de recherche Royallieu, Compiègne, France
| | - Fabrice Charleux
- ACRIM-Polyclinique Saint Côme, Medical Radiology, Compiègne, France
| | - Sabine F Bensamoun
- Université de technologie de Compiègne, CNRS, Biomechanics and Bioengineering, Centre de recherche Royallieu, Compiègne, France
| | | | | |
Collapse
|
20
|
Takagi R, Washio T, Koseki Y. The feasibility of a noise elimination method using continuous wave response of therapeutic ultrasound signals for ultrasonic monitoring of high-intensity focused ultrasound treatment. J Med Ultrason (2001) 2021; 48:123-135. [PMID: 33796908 PMCID: PMC8079307 DOI: 10.1007/s10396-021-01083-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 02/16/2021] [Indexed: 11/30/2022]
Abstract
Purpose In this study, the robustness and feasibility of a noise elimination method using continuous wave response of therapeutic ultrasound signals were investigated when tissue samples were moved to simulate the respiration-induced movements of the different organs during actual high-intensity focused ultrasound (HIFU) treatment. In addition to that, the failure conditions of the proposed algorithm were also investigated. Methods The proposed method was applied to cases where tissue samples were moved along both the lateral and axial directions of the HIFU transducer to simulate respiration-induced motions during HIFU treatment, and the noise reduction level was investigated. In this experiment, the speed of movement was increased from 10 to 40 mm/s to simulate the actual movement of the tissue during HIFU exposure, with the intensity and driving frequency of HIFU set to 1.0–5.0 kW/cm2 and 1.67 MHz, respectively. To investigate the failure conditions of the proposed algorithm, the proposed method was applied with the HIFU focus located at the boundary between the phantom and water to easily cause cavitation bubbles. The intensity of HIFU was set to 10 kW/cm2. Results Almost all HIFU noise was constantly able to be eliminated using the proposed method when the phantom was moved along the lateral and axial directions during HIFU exposure. The noise reduction level (PRL in this study) at an intensity of 1.0, 3.0, and 5.0 kW/cm2 was in the range of 28–32, 38–40, and 42–45 dB, respectively. On the other hand, HIFU noise was not basically eliminated during HIFU exposure after applying the proposed method in the case of cavitation generation at the HIFU focus. Conclusions The proposed method can be applicable even if homogeneous tissues or organs move axially or laterally to the direction of HIFU exposure because of breathing. A condition under which the proposed algorithm failed was when instantaneous tissue changes such as cavitation bubble generation occurred in the tissue, at which time the reflected continuous wave response became less steady.
Collapse
Affiliation(s)
- Ryo Takagi
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan.
| | - Toshikatsu Washio
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| | - Yoshihiko Koseki
- Health and Medical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan
| |
Collapse
|
21
|
Hill CS, Han-Oh S, Cheng Z, Wang KKH, Meyer JJ, Herman JM, Narang AK. Fiducial-based image-guided SBRT for pancreatic adenocarcinoma: Does inter-and intra-fraction treatment variation warrant adaptive therapy? Radiat Oncol 2021; 16:53. [PMID: 33741015 PMCID: PMC7980583 DOI: 10.1186/s13014-021-01782-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Accepted: 03/10/2021] [Indexed: 12/25/2022] Open
Abstract
Purpose Variation in target positioning represents a challenge to set-up reproducibility and reliability of dose delivery with stereotactic body radiation therapy (SBRT) for pancreatic adenocarcinoma (PDAC). While on-board imaging for fiducial matching allows for daily shifts to optimize target positioning, the magnitude of the shift as a result of inter- and intra-fraction variation may directly impact target coverage and dose to organs-at-risk. Herein, we characterize the variation patterns for PDAC patients treated at a high-volume institution with SBRT. Methods We reviewed 30 consecutive patients who received SBRT using active breathing coordination (ABC). Patients were aligned to bone and then subsequently shifted to fiducials. Inter-fraction and intra-fraction scans were reviewed to quantify the mean and maximum shift along each axis, and the shift magnitude. A linear regression model was conducted to investigate the relationship between the inter- and intra-fraction shifts. Results The mean inter-fraction shift in the LR, AP, and SI axes was 3.1 ± 1.8 mm, 2.9 ± 1.7 mm, and 3.5 ± 2.2 mm, respectively, and the mean vector shift was 6.4 ± 2.3 mm. The mean intra-fraction shift in the LR, AP, and SI directions were 2.0 ± 0.9 mm, 2.0 ± 1.3 mm, and 2.3 ± 1.4 mm, respectively, and the mean vector shift was 4.3 ± 1.8 mm. A linear regression model showed a significant relationship between the inter- and intra-fraction shift in the AP and SI axis and the shift magnitude. Conclusions Clinically significant inter- and intra-fraction variation occurs during treatment of PDAC with SBRT even with a comprehensive motion management strategy that utilizes ABC. Future studies to investigate how these variations could lead to variation in the dose to the target and OAR should be investigated. Strategies to mitigate the dosimetric impact, including real time imaging and adaptive therapy, in select cases should be considered. Supplementary Information The online version contains supplementary material available at 10.1186/s13014-021-01782-w.
Collapse
Affiliation(s)
- Colin S Hill
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, 401 N. Broadway, Suite 1440, Baltimore, MD, 21231, USA.
| | - Sarah Han-Oh
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, 401 N. Broadway, Suite 1440, Baltimore, MD, 21231, USA
| | - Zhi Cheng
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, 401 N. Broadway, Suite 1440, Baltimore, MD, 21231, USA
| | - Ken Kang-Hsin Wang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, 401 N. Broadway, Suite 1440, Baltimore, MD, 21231, USA
| | - Jeffrey J Meyer
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, 401 N. Broadway, Suite 1440, Baltimore, MD, 21231, USA
| | - Joseph M Herman
- Radiation Medicine, Zucker School of Medicine At Hofstra/Northwell, Lake Success, USA
| | - Amol K Narang
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, 401 N. Broadway, Suite 1440, Baltimore, MD, 21231, USA
| |
Collapse
|
22
|
Effects of laparoscopy, laparotomy, and respiratory phase on liver volume in a live porcine model for liver resection. Surg Endosc 2021; 35:7049-7057. [PMID: 33398570 PMCID: PMC8599330 DOI: 10.1007/s00464-020-08220-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Accepted: 12/03/2020] [Indexed: 12/16/2022]
Abstract
Background Hepatectomy, living donor liver transplantations and other major hepatic interventions rely on precise calculation of the total, remnant and graft liver volume. However, liver volume might differ between the pre- and intraoperative situation. To model liver volume changes and develop and validate such pre- and intraoperative assistance systems, exact information about the influence of lung ventilation and intraoperative surgical state on liver volume is essential. Methods This study assessed the effects of respiratory phase, pneumoperitoneum for laparoscopy, and laparotomy on liver volume in a live porcine model. Nine CT scans were conducted per pig (N = 10), each for all possible combinations of the three operative (native, pneumoperitoneum and laparotomy) and respiratory states (expiration, middle inspiration and deep inspiration). Manual segmentations of the liver were generated and converted to a mesh model, and the corresponding liver volumes were calculated. Results With pneumoperitoneum the liver volume decreased on average by 13.2% (112.7 ml ± 63.8 ml, p < 0.0001) and after laparotomy by 7.3% (62.0 ml ± 65.7 ml, p = 0.0001) compared to native state. From expiration to middle inspiration the liver volume increased on average by 4.1% (31.1 ml ± 55.8 ml, p = 0.166) and from expiration to deep inspiration by 7.2% (54.7 ml ± 51.8 ml, p = 0.007). Conclusions Considerable changes in liver volume change were caused by pneumoperitoneum, laparotomy and respiration. These findings provide knowledge for the refinement of available preoperative simulation and operation planning and help to adjust preoperative imaging parameters to best suit the intraoperative situation.
Collapse
|
23
|
Zeng C, Li X, Lu W, Reyngold M, Gewanter RM, Cuaron JJ, Yorke E, Li T. Accuracy and efficiency of respiratory gating comparable to deep inspiration breath hold for pancreatic cancer treatment. J Appl Clin Med Phys 2020; 22:218-225. [PMID: 33378792 PMCID: PMC7856516 DOI: 10.1002/acm2.13137] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 11/06/2020] [Accepted: 12/01/2020] [Indexed: 12/25/2022] Open
Abstract
Purpose Deep inspiration breath hold (DIBH) and respiratory gating (RG) are widely used to reduce movement of target and healthy organs caused by breathing during irradiation. We hypothesized that accuracy and efficiency comparable to DIBH can be achieved with RG for pancreas treatment. Methods and Materials Twenty consecutive patients with pancreatic cancer treated with DIBH (eight) or RG (twelve) volumetric modulated arc therapy during 2017–2019 were included in this study, with radiopaque markers implanted near or in the targets. Seventeen patients received 25 fractions, while the other three received 15 fractions. Only patients who could not tolerate DIBH received RG treatment. While both techniques relied on respiratory signals from external markers, internal target motions were monitored with kV X‐ray imaging during treatment. A 3‐mm external gating window was used for DIBH treatment; RG treatment was centered on end‐expiration with a duty cycle of 40%, corresponding to an external gating window of 2–3 mm. During dose delivery, kV images were automatically taken every 20◦ or 40◦ gantry rotation, from which internal markers were identified. The marker displacement from their initial positions and the residual motion amplitudes were calculated. For the analysis of treatment efficiency, the treatment time of every session was calculated from the motion management waveform files recorded at the treatment console. Results Within one fraction, the displacement was 0–5 mm for DIBH and 0–6 mm for RG. The average magnitude of displacement for each patient during the entire course of treatment ranged 0–3 mm for both techniques. No statistically significant difference in displacement or residual motion was observed between the two techniques. The average treatment time was 15 min for DIBH and 17 min for RG, with no statistical significance. Conclusions The accuracy and efficiency were comparable between RG and DIBH treatment for pancreas irradiation. RG is a feasible alternative strategy to DIBH.
Collapse
Affiliation(s)
- Chuan Zeng
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Xiang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Wei Lu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Marsha Reyngold
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Richard M Gewanter
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - John J Cuaron
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Ellen Yorke
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Tianfang Li
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
24
|
Ono S, Ueda Y, Inui S, Isono M, Ohira S, Murata S, Miyazaki M, Teshima T. Dosimetric impact of baseline drift in volumetric modulated arc therapy with breath holding. Rep Pract Oncol Radiother 2020; 25:703-708. [PMID: 32684857 PMCID: PMC7358624 DOI: 10.1016/j.rpor.2020.06.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Revised: 04/17/2020] [Accepted: 06/01/2020] [Indexed: 10/24/2022] Open
Abstract
BACKGROUND We investigated the change of dose distributions in volumetric modulated arc therapy (VMAT) under baseline drift (BD) during breath holding. MATERIALS AND METHODS Ten VMAT plans recalculated to a static field at a gantry angle of 0° were prepared for measurement with a 2D array device and five original VMAT plans were prepared for measurement with gafchromic films. These measurement approaches were driven by a waveform reproducing breath holding with BD. We considered breath holding times of 15 and 10 s, and BD at four speeds; specifically, BD0 (0 mm/s), BD0.2 (0.2 mm/s), BD0.3 (0.3 mm/s), and BD0.4 (0.4 mm/s). The BD was periodically reproduced from the isocenter along the craniocaudal direction and the shift during breath holding (ShiftBH) ranged 0-6 mm.The dose distribution of BD0.2, BD0.3 and BD0.4 were compared to that of BD0 using gamma analysis with the criterion of 2%/2 mm. RESULTS The mean pass rates of each ShiftBH were 99.8% and 98.9% at 0 mm, 96.8% and 99.4% at 2 mm, 94.9% and 98.6% at 3 mm, 91.5% and 98.4% at 4 mm, 70.8% and 94.1% at 4.5 mm, and 55.0% and 83.6% at 6 mm for the array and film measurements, respectively. CONCLUSION We found significant differences in ShiftBH above 4 mm (ρ < 0.05). Hence, it is recommended that breath holding time should be shortened for patients to preserve the reproducibility of dose distributions.
Collapse
Affiliation(s)
- Shunsuke Ono
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| | - Yoshihiro Ueda
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| | - Shoki Inui
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| | - Masaru Isono
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| | - Shingo Ohira
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| | - Seiya Murata
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| | - Masayoshi Miyazaki
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| | - Teruki Teshima
- Department of Radiation Oncology, Osaka International Cancer Institute, 3-1-69 Otemae, Chuou-ku, Osaka, 537-8567, Japan
| |
Collapse
|
25
|
Luo H, Zhu A, Wiens CN, Starekova J, Shimakawa A, Reeder SB, Johnson KM, Hernando D. Free-breathing liver fat and R 2 ∗ quantification using motion-corrected averaging based on a nonlocal means algorithm. Magn Reson Med 2020; 85:653-666. [PMID: 32738089 DOI: 10.1002/mrm.28439] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 06/27/2020] [Accepted: 06/29/2020] [Indexed: 01/01/2023]
Abstract
PURPOSE To propose a motion-robust chemical shift-encoded (CSE) method with high signal-to-noise (SNR) for accurate quantification of liver proton density fat fraction (PDFF) and R 2 ∗ . METHODS A free-breathing multi-repetition 2D CSE acquisition with motion-corrected averaging using nonlocal means (NLM) was proposed. PDFF and R 2 ∗ quantified with 2D CSE-NLM were compared to two alternative 2D techniques: direct averaging and single acquisition (2D 1ave) in a digital phantom. Further, 2D NLM was compared in patients to 3D techniques (standard breath-hold, free-breathing and navigated), and the alternative 2D techniques. A reader study and quantitative analysis (Bland-Altman, correlation analysis, paired Student's t-test) were performed to evaluate the image quality and assess PDFF and R 2 ∗ measurements in regions of interest. RESULTS In simulations, 2D NLM resulted in lower standard deviations (STDs) of PDFF (2.7%) and R 2 ∗ (8.2 s - 1 ) compared to direct averaging (PDFF: 3.1%, R 2 ∗ : 13.6 s - 1 ) and 2D 1ave (PDFF: 8.7%, R 2 ∗ : 33.2 s - 1 ). In patients, 2D NLM resulted in fewer motion artifacts than 3D free-breathing and 3D navigated, less signal loss than 2D direct averaging, and higher SNR than 2D 1ave. Quantitatively, the STDs of PDFF and R 2 ∗ of 2D NLM were comparable to those of 2D direct averaging (p>0.05). 2D NLM reduced bias, particularly in R 2 ∗ (-5.73 to -0.36 s - 1 ) that arises in direct averaging (-3.96 to 11.22 s - 1 ) in the presence of motion. CONCLUSIONS 2D CSE-NLM enables accurate mapping of PDFF and R 2 ∗ in the liver during free-breathing.
Collapse
Affiliation(s)
- Huiwen Luo
- Radiology, University of Wisconsin-Madison, Madison, WI, USA.,Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.,Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA
| | - Ante Zhu
- Radiology, University of Wisconsin-Madison, Madison, WI, USA.,Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA
| | - Curtis N Wiens
- Radiology, University of Wisconsin-Madison, Madison, WI, USA
| | - Jitka Starekova
- Radiology, University of Wisconsin-Madison, Madison, WI, USA
| | - Ann Shimakawa
- Global MR Applications and Workflow, GE Healthcare, Madison, WI, USA
| | - Scott B Reeder
- Radiology, University of Wisconsin-Madison, Madison, WI, USA.,Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA.,Medical Physics, University of Wisconsin-Madison, Madison, WI, USA.,Medicine, University of Wisconsin-Madison, Madison, WI, USA.,Emergency Medicine, University of Wisconsin-Madison, Madison, WI, USA
| | - Kevin M Johnson
- Radiology, University of Wisconsin-Madison, Madison, WI, USA.,Medical Physics, University of Wisconsin-Madison, Madison, WI, USA
| | - Diego Hernando
- Radiology, University of Wisconsin-Madison, Madison, WI, USA.,Biomedical Engineering, Vanderbilt University, Nashville, TN, USA.,Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, USA.,Medical Physics, University of Wisconsin-Madison, Madison, WI, USA.,Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, USA
| |
Collapse
|
26
|
Kosieradzki M, Lisik W, Gierwiało R, Sitnik R. Applicability of Augmented Reality in an Organ Transplantation. Ann Transplant 2020; 25:e923597. [PMID: 32732862 PMCID: PMC7418780 DOI: 10.12659/aot.923597] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2020] [Accepted: 02/20/2020] [Indexed: 12/20/2022] Open
Abstract
Augmented reality (AR) delivers virtual information or some of its elements to the real world. This technology, which has been used primarily for entertainment and military applications, has vigorously entered medicine, especially in radiology and surgery, yet has never been used in organ transplantation. AR could be useful in training transplant surgeons, promoting organ donations, graft retrieval and allocation, and microscopic diagnosis of rejection, treatment of complications, and post-transplantation neoplasms. The availability of AR display tools such as Smartphone screens and head-mounted goggles, accessibility of software for automated image segmentation and 3-dimensional reconstruction, and algorithms allowing registration, make augmented reality an attractive tool for surgery including transplantation. The shortage of hospital IT specialists and insufficient investments from medical equipment manufacturers into the development of AR technology remain the most significant obstacles in its broader application.
Collapse
Affiliation(s)
- Maciej Kosieradzki
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Warsaw, Poland
| | - Wojciech Lisik
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Warsaw, Poland
| | - Radosław Gierwiało
- Virtual Reality Techniques Division, Institute of Micromechanics and Photonics, Faculty of Mechatronics, Warsaw University of Technology, Warsaw, Poland
| | - Robert Sitnik
- Virtual Reality Techniques Division, Institute of Micromechanics and Photonics, Faculty of Mechatronics, Warsaw University of Technology, Warsaw, Poland
| |
Collapse
|
27
|
Walker MD, Morgan AJ, Bradley KM, McGowan DR. Data-Driven Respiratory Gating Outperforms Device-Based Gating for Clinical 18F-FDG PET/CT. J Nucl Med 2020; 61:1678-1683. [PMID: 32245898 DOI: 10.2967/jnumed.120.242248] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Accepted: 03/16/2020] [Indexed: 11/16/2022] Open
Abstract
A data-driven method for respiratory gating in PET has recently been commercially developed. We sought to compare the performance of the algorithm with an external, device-based system for oncologic 18F-FDG PET/CT imaging. Methods: In total, 144 whole-body 18F-FDG PET/CT examinations were acquired, with a respiratory gating waveform recorded by an external, device-based respiratory gating system. In each examination, 2 of the bed positions covering the liver and lung bases were acquired with a duration of 6 min. Quiescent-period gating retaining approximately 50% of coincidences was then able to produce images with an effective duration of 3 min for these 2 bed positions, matching the other bed positions. For each examination, 4 reconstructions were performed and compared: data-driven gating (DDG) (we use the term DDG-retro to distinguish that we did not use the real-time R-threshold-based application of DDG that is available within the manufacturer's product), external device-based gating (real-time position management (RPM)-gated), no gating but using only the first 3 min of data (ungated-matched), and no gating retaining all coincidences (ungated-full). Lesions in the images were quantified and image quality scored by a radiologist who was masked to the method of data processing. Results: Compared with the other reconstruction options, DDG-retro increased the SUVmax and decreased the threshold-defined lesion volume. Compared with RPM-gated, DDG-retro gave an average increase in SUVmax of 0.66 ± 0.1 g/mL (n = 87, P < 0.0005). Although the results from the masked image evaluation were most commonly equivalent, DDG-retro was preferred over RPM-gated in 13% of examinations, whereas the opposite occurred in just 2% of examinations. This was a significant preference for DDG-retro (P = 0.008, n = 121). Liver lesions were identified in 23 examinations. Considering this subset of data, DDG-retro was ranked superior to ungated-full in 6 of 23 (26%) cases. Gated reconstruction using the external device failed in 16% of examinations, whereas DDG-retro always provided a clinically acceptable image. Conclusion: In this clinical evaluation, DDG-retro provided performance superior to that of the external device-based system. For most examinations the performance was equivalent, but DDG-retro had superior performance in 13% of examinations, leading to a significant preference overall.
Collapse
Affiliation(s)
- Matthew D Walker
- Radiation Physics and Protection, Oxford University Hospitals NHS FT, Oxford, United Kingdom
| | - Andrew J Morgan
- Radiation Physics and Protection, Oxford University Hospitals NHS FT, Oxford, United Kingdom
| | - Kevin M Bradley
- Department of Radiology, Churchill Hospital, Oxford, United Kingdom.,Wales Research and Diagnostic PET Imaging Centre, Cardiff University, Cardiff, United Kingdom; and
| | - Daniel R McGowan
- Radiation Physics and Protection, Oxford University Hospitals NHS FT, Oxford, United Kingdom.,Department of Oncology, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
28
|
Chu KY, Cooke R, Van den Heuvel F, Mukherjee S, Hawkins MA. Impact of abdominal compression on setup error and image matching during radical abdominal radiotherapy. Tech Innov Patient Support Radiat Oncol 2019; 12:28-33. [PMID: 32095552 PMCID: PMC7033789 DOI: 10.1016/j.tipsro.2019.11.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 10/31/2019] [Accepted: 11/11/2019] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To determine the impact of abdominal compression (AC) on setup error and image matching time. MATERIALS AND METHODS This study included 72 liver, pancreas and abdominal node patients treated radically from 2016 to 2019 in a single centre. Patients received either SBRT or conventional radical fractionation (CRF). Compressed patients were supine, arms up with kneefix and AC equipment. Uncompressed patients were supine, arms up with kneefix. All patients received daily online-matched CBCTs before treatment. Initial setup error was determined for all patients. Registration error was assessed for 10 liver and 10 pancreas patients. Image matching times were determined using beam on times. Statistical tests conducted were an F-test to compare variances in setup error, Student's t-tests for setup error and average image analysis, and a Wilcoxon Mann Whitney test for imaging matching time analysis. RESULTS Initial setup displacement was similar between compressed and uncompressed patients. Displacements > 1 cm occurred more frequently in the longitudinal direction for most patients. SBRT patients required more additional manual positioning following imaging. Mean absolute registration error in the SI direction was 5.4 mm and 3.3 mm for uncompressed and compressed pancreas patients respectively and 1.7 mm and 0.8 mm for uncompressed and compressed liver patients respectively. Compressed patients required less time for image matching and fewer images per fraction on average. Repeat imaging occurred more frequently in SBRT and uncompressed patients. CONCLUSIONS Although abdominal compression has no significant impact on setup error, it can reduce imaging matching times resulting in improved treatment accuracy.
Collapse
Affiliation(s)
- Kwun-Ye Chu
- CRUK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
- Oxford University Hospitals NHS FT, Churchill Hospital, Old Road, Oxford OX3 7LE, United Kingdom
| | - Rosie Cooke
- CRUK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
- Oxford University Hospitals NHS FT, Churchill Hospital, Old Road, Oxford OX3 7LE, United Kingdom
| | - Frank Van den Heuvel
- CRUK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
- Oxford University Hospitals NHS FT, Churchill Hospital, Old Road, Oxford OX3 7LE, United Kingdom
| | - Somnath Mukherjee
- CRUK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
- Oxford University Hospitals NHS FT, Churchill Hospital, Old Road, Oxford OX3 7LE, United Kingdom
| | - Maria A. Hawkins
- CRUK/MRC Oxford Institute for Radiation Oncology, Department of Oncology, University of Oxford, Old Road Campus Research Building, Roosevelt Drive, Oxford OX3 7DQ, United Kingdom
| |
Collapse
|
29
|
Oar A, Lee M, Le H, Hruby G, Dalfsen R, Pryor D, Lee D, Chu J, Holloway L, Briggs A, Barbour A, Chander S, Ng SP, Samra J, Shakeshaft J, Goldstein D, Nguyen N, Goodman KA, Chang DT, Kneebone A. Australasian Gastrointestinal Trials Group (AGITG) and Trans-Tasman Radiation Oncology Group (TROG) Guidelines for Pancreatic Stereotactic Body Radiation Therapy (SBRT). Pract Radiat Oncol 2019; 10:e136-e146. [PMID: 31761541 DOI: 10.1016/j.prro.2019.07.018] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 07/28/2019] [Accepted: 07/31/2019] [Indexed: 02/07/2023]
Abstract
PURPOSE Nonrandomized data exploring pancreas stereotactic body radiation therapy (SBRT) has demonstrated excellent local control rates and low toxicity. Before commencing a randomized trial investigating pancreas SBRT, standardization of prescription dose, dose constraints, simulation technique, and clinical target volume delineation are required. METHODS AND MATERIALS Specialists in radiation oncology, medical oncology, hepatobiliary surgery, and gastroenterology attended 2 consecutive Australasian Gastrointestinal Trials Group workshops in 2017 and 2018. Sample cases were discussed during workshop contact with specifically invited international speakers highly experienced in pancreas SBRT. Furthermore, sample cases were contoured and planned between workshop contact to finalize dose constraints and clinical target volume delineation. RESULTS Over 2 separate workshops, consensus was reached on dose and simulation technique. The working group recommended a dose prescription of 40 Gy in 5 fractions. Treatment delivery during end-expiratory breath hold with triple-phase contrast enhanced computed tomography was recommended. In addition, dose constraints, stepwise contouring guidelines, and an anatomic atlas for pancreatic SBRT were developed. CONCLUSIONS Pancreas SBRT is emerging as a promising treatment modality requiring prospective evaluation in randomized studies. This work attempts to standardize dose, simulation technique, and volume delineation to support the delivery of high quality SBRT in a multicenter study.
Collapse
Affiliation(s)
- Andrew Oar
- Icon Cancer Centre, Gold Coast University Hospital, Gold Coast; Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia.
| | - Mark Lee
- Icon Cancer Centre, Gold Coast University Hospital, Gold Coast
| | - Hien Le
- Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide, Australia
| | - George Hruby
- Royal North Shore Hospital, Sydney, Australia; University of Sydney, Sydney, Australia
| | - Raymond Dalfsen
- Department of Radiation Oncology, Royal Adelaide Hospital, Adelaide, Australia
| | - David Pryor
- Princess Alexandra Hospital, Brisbane, Australia
| | | | - Julie Chu
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - Lois Holloway
- Liverpool and Macarthur Cancer Therapy Centres, Sydney, Australia; South Western Clinical School, University of New South Wales, Sydney, Australia; Institute of Medical Physics, University of Sydney, Sydney, Australia; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, Australia
| | - Adam Briggs
- Royal North Shore Hospital, Sydney, Australia
| | - Andrew Barbour
- Princess Alexandra Hospital, Brisbane, Australia; University of Queensland, Diamantina Institute, Translational Research Institute, Woolloongabba, Australia
| | - Sarat Chander
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - Sweet Ping Ng
- Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
| | - Jas Samra
- Royal North Shore Hospital, Sydney, Australia; University of Sydney, Sydney, Australia
| | - John Shakeshaft
- Icon Cancer Centre, Gold Coast University Hospital, Gold Coast
| | - David Goldstein
- Department of Medical Oncology, Nelune Cancer Centre, Prince of Wales Hospital, Sydney, Australia; Prince of Wales Clinical School, University of New South Wales, Sydney, Australia
| | - Nam Nguyen
- Department of Gastroenterology and Hepatology, Royal Adelaide Hospital, Discipline of Medicine, University of Adelaide, Adelaide, Australia
| | - Karyn A Goodman
- Department of Radiation Oncology, University of Colorado School of Medicine, Aurora, Colorado
| | | | - Andrew Kneebone
- Royal North Shore Hospital, Sydney, Australia; University of Sydney, Sydney, Australia
| |
Collapse
|
30
|
de Jong TL, Moelker A, Dankelman J, van den Dobbelsteen JJ. Designing and validating a PVA liver phantom with respiratory motion for needle-based interventions. Int J Comput Assist Radiol Surg 2019; 14:2177-2186. [PMID: 31297650 PMCID: PMC6858400 DOI: 10.1007/s11548-019-02029-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Accepted: 07/03/2019] [Indexed: 11/30/2022]
Abstract
Purpose The purpose is to design and validate an anthropomorphic polyvinyl alcohol (PVA) liver phantom with respiratory motion to simulate needle-based interventions. Such a system can, for example, be used as a validation tool for novel needles. Methods Image segmentations of CT scans of four patients during inspiration and expiration were used to measure liver and rib displacement. An anthropomorphic liver mold based on a CT scan was 3D printed and filled with 5% w/w PVA-to-water, undergoing two freeze–thaw cycles, in addition to a 3D-printed compliant rib cage. They were both held in place by a PVA abdominal phantom. A sinusoidal motion vector, based on the measured liver displacement, was applied to the liver phantom by means of a motion stage. Liver, rib cage and needle deflection were tracked by placing electromagnetic sensors on the phantom. Liver and rib cage phantom motion was validated by comparison with the CT images of the patients, whereas needle deflection was compared with the literature. Results CT analysis showed that from the state of expiration to inspiration, the livers moved predominantly toward the right (mean: 2 mm, range: − 11 to 11 mm), anterior (mean: 15 mm, range: 9–21 mm) and caudal (mean: 16 mm, range: 6–24 mm) direction. The mechatronic design of the liver phantom gives the freedom to set direction and amplitude of the motion and was able to mimic the direction of liver motion of one patient. Needle deflection inside the phantom increased from 1.6 to 3.8 mm from the initial expiration state to inspiration. Conclusions The developed liver phantom allows for applying different motion patterns and shapes/sizes and thus allows for patient-specific simulation of needle-based interventions. Moreover, it is able to mimic appropriate respiratory motion and needle deflection as observed in patients. Electronic supplementary material The online version of this article (10.1007/s11548-019-02029-6) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Tonke L de Jong
- BioMechanical Engineering Department, Delft University of Technology, Delft, The Netherlands.
| | - Adriaan Moelker
- Radiology and Nuclear Medicine Department, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - Jenny Dankelman
- BioMechanical Engineering Department, Delft University of Technology, Delft, The Netherlands
| | | |
Collapse
|
31
|
Cheng CP, Suh GY, Kim JJ, Holden A. Cardiac Pulsatility- and Respiratory-Induced Deformations of the Renal Arteries and Snorkel Stents After Snorkel Endovascular Aneurysm Sealing. J Endovasc Ther 2019; 26:556-564. [PMID: 31210077 DOI: 10.1177/1526602819856363] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose: To quantify deformations of renal arteries and snorkel stents after snorkel endovascular aneurysm sealing (Sn-EVAS) resulting from cardiac pulsatility and respiration and compare these deformations to patients with untreated abdominal aortic aneurysms (AAA) and snorkel endovascular aneurysm repair (Sn-EVAR). Materials and Methods: Ten Sn-EVAS patients (mean age 75±6 years; 8 men) were scanned with cardiac-gated, respiration-resolved computed tomography angiography. From 3-dimensional geometric models, changes in renal artery and stent angulation and curvature due to cardiac pulsatility and respiration were quantified. Respiration-induced motions were compared with those of 16 previously reported untreated AAA patients and 11 Sn-EVAR patients. Results: Renal artery bending at the stent end was greater for respiratory vs cardiac influences (6°±7° vs -1°±2°, p<0.025). Respiration caused a 3-fold greater deformation on the left renal artery as compared with the right side. Maximum curvature change was higher for respiratory vs cardiac influences (0.49±0.29 vs 0.24±0.17 cm-1, p<0.025), and snorkel renal stents experienced similar maximum curvature change due to cardiac pulsatility and respiration (0.14±0.10 vs 0.19±0.09 cm-1, p=0.142). When comparing the 3 patient cohorts for respiratory-induced deformation, there was significant renal branch angulation in untreated AAAs, but not in Sn-EVAR or Sn-EVAS, and there was significant bending at the stent end in Sn-EVAR and Sn-EVAS. Maximum curvature change due to respiration was ~10-fold greater in Sn-EVAR and Sn-EVAS compared to untreated AAAs. Conclusion: The findings suggest that cardiac and respiratory influences may challenge the mechanical durability of snorkel stents of Sn-EVAS; similarly, however, respiration may be the primary culprit for tissue irritation, increasing the risk for stent-end thrombosis, especially in the left renal artery. The bending stiffness of snorkel stents in both the Sn-EVAR and Sn-EVAS cohorts damped renal branch angulation while it intensified bending of the artery distal to the snorkel stent. Understanding these device-to-artery interactions is critical as they may affect mechanical durability of branch stents and quality and durability of treatment.
Collapse
Affiliation(s)
| | - Ga-Young Suh
- 1 Department of Surgery, Stanford University, Stanford, CA, USA
| | - John J Kim
- 1 Department of Surgery, Stanford University, Stanford, CA, USA
| | - Andrew Holden
- 2 Department of Anatomy and Medical Imaging, University of Auckland, New Zealand
| |
Collapse
|
32
|
Zeng C, Xiong W, Li X, Reyngold M, Gewanter RM, Cuaron JJ, Yorke ED, Li T. Intrafraction tumor motion during deep inspiration breath hold pancreatic cancer treatment. J Appl Clin Med Phys 2019; 20:37-43. [PMID: 30933428 PMCID: PMC6523018 DOI: 10.1002/acm2.12577] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2019] [Revised: 02/27/2019] [Accepted: 03/05/2019] [Indexed: 12/25/2022] Open
Abstract
Purpose Beam gating with deep inspiration breath hold (DIBH) has been widely used for motion management in radiotherapy. Normally it relies on some external surrogate for estimating the internal target motion, while the exact internal motion is unknown. In this study, we used the intrafraction motion review (IMR) application to directly track an internal target and characterized the residual motion during DIBH treatment for pancreatic cancer patients through their full treatment courses. Methods and Materials Eight patients with pancreatic cancer treated with DIBH volumetric modulated arc therapy in 2017 and 2018 were selected for this study, each with some radiopaque markers (fiducial or surgical clips) implanted near or inside the target. The Varian Real‐time Position Management (RPM) system was used to monitor the breath hold, represented by the anterior‐posterior displacement of an external surrogate, namely reflective markers mounted on a plastic block placed on the patient's abdomen. Before each treatment, a cone beam computed tomography (CBCT) scan under DIBH was acquired for patient setup. For scan and treatment, the breath hold reported by RPM had to lie within a 3 mm window. IMR kV images were taken every 20° or 40° gantry rotation during dose delivery, resulting in over 5000 images for the cohort. The internal markers were manually identified in the IMR images. The residual motion amplitudes of the markers as well as the displacement from their initial positions located in the setup CBCT images were analyzed. Results Even though the external markers indicated that the respiratory motion was within 3 mm in DIBH treatment, significant residual internal target motion was observed for some patients. The range of average motion was from 3.4 to 7.9 mm, with standard deviation ranging from 1.2 to 3.5 mm. For all patients, the target residual motions seemed to be random with mean positions around their initial setup positions. Therefore, the absolute target displacement relative to the initial position was small during DIBH treatment, with the mean and the standard deviation 0.6 and 2.9 mm, respectively. Conclusions Internal target motion may differ from external surrogate motion in DIBH treatment. Radiographic verification of target position at the beginning and during each fraction is necessary for precise RT delivery. IMR can serve as a useful tool to directly monitor the internal target motion.
Collapse
Affiliation(s)
- Chuan Zeng
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Weijun Xiong
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Xiang Li
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | | | | | - John J Cuaron
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Ellen D Yorke
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Tianfang Li
- Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
33
|
Dolde K, Dávid C, Echner G, Floca R, Hentschke C, Maier F, Niebuhr N, Ohmstedt K, Saito N, Alimusaj M, Fluegel B, Naumann P, Dreher C, Freitag M, Pfaffenberger A. 4DMRI-based analysis of inter— and intrafractional pancreas motion and deformation with different immobilization devices. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/aaf9ae] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
34
|
Hahn S, Absil J, Debeir O, Metens T. Assessment of cardiac-driven liver movements with filtered harmonic phase image representation, optical flow quantification, and motion amplification. Magn Reson Med 2018; 81:2788-2798. [PMID: 30485536 DOI: 10.1002/mrm.27596] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2018] [Revised: 09/21/2018] [Accepted: 10/17/2018] [Indexed: 12/28/2022]
Abstract
PURPOSE To characterize cardiac-driven liver movements using a harmonic phase image representation (HARP) with an optical flow quantification and motion amplification method. The method was applied to define the cardiac trigger delay providing minimal signal losses in liver DWI images. METHODS The 16-s breath-hold balanced-SSFP time resolved 20 images/s were acquired at 3T in coronal and sagittal orientations. A peripheral pulse unit signal was recorded. Cardiac-triggered DWI images were acquired after different peripheral pulse unit delays. A steerable pyramid decomposition with multiple orientations and spatial frequencies was applied. The liver motion field-map was derived from temporal variations of the HARP representation filtered around the cardiac frequency. Liver displacements were quantified with an optical flow method; moreover the right liver motion was amplified. RESULTS The largest displacements were observed in the left liver (feet-head:3.70 ± 1.06 mm; anterior-posterior: 2.35 ± 0.51 mm). Displacements were statistically significantly weaker in the middle right liver (0.47 ± 0.11 mm; P = 0.0156). The average error was 0.013 ± 0.022 mm (coronal plane) and 0.021 ± 0.041 mm (sagittal plane). The velocity field demonstrated opposing movements of the right liver extremities during the cardiac cycle. DWI signal loss was minimized in regions and instants of smallest amplitude of both velocity and velocity gradient. CONCLUSION Cardiac-driven liver movements were quantified with combined cardiac frequency-filtered HARP and optical flow methods. A motion phase opposition between right liver extremities was demonstrated. Displacement amplitude and velocity were larger in the left liver especially along the vertical direction. Motion amplification visually emphasized cardiac-driven right liver displacements. The optimal cardiac timing minimizing signal loss in liver DWI images was derived.
Collapse
Affiliation(s)
- Stephan Hahn
- LISA - IMAGE: Laboratories of Image, Signal processing and Acoustics, Université Libre de Bruxelles, Brussels, Belgium
| | - Julie Absil
- Department of Radiology- Magnetic Resonance Imaging, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium
| | - Olivier Debeir
- LISA - IMAGE: Laboratories of Image, Signal processing and Acoustics, Université Libre de Bruxelles, Brussels, Belgium
| | - Thierry Metens
- Department of Radiology- Magnetic Resonance Imaging, Hôpital Erasme, Université Libre de Bruxelles, Brussels, Belgium
| |
Collapse
|
35
|
Menten MJ, Fast MF, Wetscherek A, Rank CM, Kachelrieß M, Collins DJ, Nill S, Oelfke U. The impact of 2D cine MR imaging parameters on automated tumor and organ localization for MR-guided real-time adaptive radiotherapy. Phys Med Biol 2018; 63:235005. [PMID: 30465542 PMCID: PMC6372137 DOI: 10.1088/1361-6560/aae74d] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 09/22/2018] [Accepted: 10/10/2018] [Indexed: 12/25/2022]
Abstract
2D cine MR imaging may be utilized to monitor rapidly moving tumors and organs-at-risk for real-time adaptive radiotherapy. This study systematically investigates the impact of geometric imaging parameters on the ability of 2D cine MR imaging to guide template-matching-driven autocontouring of lung tumors and abdominal organs. Abdominal 4D MR images were acquired of six healthy volunteers and thoracic 4D MR images were obtained of eight lung cancer patients. At each breathing phase of the images, the left kidney and gallbladder or lung tumor, respectively, were outlined as volumes of interest. These images and contours were used to create artificial 2D cine MR images, while simultaneously serving as 3D ground truth. We explored the impact of five different imaging parameters (pixel size, slice thickness, imaging plane orientation, number and relative alignment of images as well as strategies to create training images). For each possible combination of imaging parameters, we generated artificial 2D cine MR images as training and test images. A template-matching algorithm used the training images to determine the tumor or organ position in the test images. Subsequently, a 3D base contour was shifted to the determined position and compared to the ground truth via centroid distance and Dice similarity coefficient. The median centroid distance between adapted and ground truth contours was 1.56 mm for the kidney, 3.81 mm for the gallbladder and 1.03 mm for the lung tumor (median Dice similarity coefficient: 0.95, 0.72 and 0.93). We observed that a decrease in image resolution led to a modest decrease in localization accuracy, especially for the small gallbladder. However, for all volumes of interest localization accuracy varied substantially more between subjects than due to the different imaging parameters. Automated tumor and organ localization using 2D cine MR imaging and template-matching-based autocontouring is robust against variation of geometric imaging parameters. Future work and optimization efforts of 2D cine MR imaging for real-time adaptive radiotherapy is needed to characterize the influence of sequence- and anatomical site-specific imaging contrast.
Collapse
Affiliation(s)
- Martin J Menten
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Martin F Fast
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, Netherlands
| | - Andreas Wetscherek
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Christopher M Rank
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - Marc Kachelrieß
- Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| | - David J Collins
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Simeon Nill
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| | - Uwe Oelfke
- Joint Department of Physics at The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
36
|
Paganelli C, Whelan B, Peroni M, Summers P, Fast M, van de Lindt T, McClelland J, Eiben B, Keall P, Lomax T, Riboldi M, Baroni G. MRI-guidance for motion management in external beam radiotherapy: current status and future challenges. Phys Med Biol 2018; 63:22TR03. [PMID: 30457121 DOI: 10.1088/1361-6560/aaebcf] [Citation(s) in RCA: 83] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
High precision conformal radiotherapy requires sophisticated imaging techniques to aid in target localisation for planning and treatment, particularly when organ motion due to respiration is involved. X-ray based imaging is a well-established standard for radiotherapy treatments. Over the last few years, the ability of magnetic resonance imaging (MRI) to provide radiation-free images with high-resolution and superb soft tissue contrast has highlighted the potential of this imaging modality for radiotherapy treatment planning and motion management. In addition, these advantageous properties motivated several recent developments towards combined MRI radiation therapy treatment units, enabling in-room MRI-guidance and treatment adaptation. The aim of this review is to provide an overview of the state-of-the-art in MRI-based image guidance for organ motion management in external beam radiotherapy. Methodological aspects of MRI for organ motion management are reviewed and their application in treatment planning, in-room guidance and adaptive radiotherapy described. Finally, a roadmap for an optimal use of MRI-guidance is highlighted and future challenges are discussed.
Collapse
Affiliation(s)
- C Paganelli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Milano, Italy. Author to whom any correspondence should be addressed. www.cartcas.polimi.it
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Retrospective evaluation of decision-making for pancreatic stereotactic MR-guided adaptive radiotherapy. Radiother Oncol 2018; 129:319-325. [DOI: 10.1016/j.radonc.2018.08.009] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 07/11/2018] [Accepted: 08/09/2018] [Indexed: 01/01/2023]
|
38
|
Suomi V, Jaros J, Treeby B, Cleveland RO. Full Modeling of High-Intensity Focused Ultrasound and Thermal Heating in the Kidney Using Realistic Patient Models. IEEE Trans Biomed Eng 2018; 65:2660-2670. [PMID: 30222549 DOI: 10.1109/tbme.2018.2870064] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE High-intensity focused ultrasound (HIFU) therapy can be used for noninvasive treatment of kidney (renal) cancer, but the clinical outcomes have been variable. In this study, the efficacy of renal HIFU therapy was studied using a nonlinear acoustic and thermal simulations in three patients. METHODS The acoustic simulations were conducted with and without refraction in order to investigate its effect on the shape, size, and pressure distribution at the focus. The values for the attenuation, sound speed, perfusion, and thermal conductivity of the kidney were varied over the reported ranges to determine the effect of variability on heating. Furthermore, the phase aberration was studied in order to quantify the underlying phase shifts using a second order polynomial function. RESULTS The ultrasound field intensity was found to drop on average 11.1 dB with refraction and 6.4 dB without refraction. Reflection at tissue interfaces was found to result in a loss less than 0.1 dB. Focal point splitting due to refraction significantly reduced the heating efficacy. Perfusion did not have a large effect on heating during short sonication durations. Small changes in temperature were seen with varying attenuation and thermal conductivity, but no visible changes were present with sound speed variations. The aberration study revealed an underlying trend in the spatial distribution of the phase shifts. CONCLUSION The results show that the efficacy of HIFU therapy in the kidney could be improved with aberration correction. SIGNIFICANCE A method is proposed by that patient specific pre-treatment calculations could be used to overcome the aberration and therefore make ultrasound treatment possible.
Collapse
|
39
|
Heerkens HD, van Vulpen M, Erickson B, Reerink O, Intven MP, van den Berg CA, Molenaar IQ, Vleggaar FP, Meijer GJ. MRI guided stereotactic radiotherapy for locally advanced pancreatic cancer. Br J Radiol 2018; 91:20170563. [PMID: 30063383 DOI: 10.1259/bjr.20170563] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVE: We want to explore the safety and technical feasibility of MRI-guided stereotactic radiotherapy for locally advanced pancreatic cancer. METHODS: A custom-made abdominal corset was manufactured to reduce breathing induced tumour motion. Delineation of the tumour and organs at risk (OARs) was performed on CT and multiparametric MRI. Tumour motion was quantified with cine MRI. After treatment planning, the static dose distribution was convolved with the cine MRI-based motion trajectory to simulate the delivered dose to the tumour and OARs. Stereotactic body radiation therapy (SBRT) was carried out up to a dose of 24 G in three fractions in 1 week. RESULTS: From July 2013 to January 2016, 20 patients were included. Tumours and OARs were clearly visible with contrast-enhanced CT and MRI. After simulation of the delivered dose taking the motion into account, an adequate target coverage was achieved with acceptable dose in the OARs. No Grade3 or higher treatment related toxicity was observed. CONCLUSION: MRI-guided SBRT for pancreatic cancer is technical feasible and safe, with no treatment related grade ≥3 toxicity. New strategies are applied, including an individual corset to reduce breathing motion, MRI-based delineation and simulation of motion-integrated dose distributions. ADVANCES IN KNOWLEDGE: This article is the first to describe an MRI-integrated workflow in SBRT for locally advanced pancreatic cancer. In addition, it demonstrated that SBRT with an abdominal corset to reduce tumour motion is feasible and safe. TRIAL REGISTRATION: This trial was registered at www.clinicaltrials.gov (NCT01898741) on July 9, 2013.
Collapse
Affiliation(s)
- Hanne D Heerkens
- 1 Department of Radiation Oncology, University Medical Center Utrecht , Utrecht , The Netherlands
| | - Marco van Vulpen
- 1 Department of Radiation Oncology, University Medical Center Utrecht , Utrecht , The Netherlands.,2 Department of Radiation Oncology, Holland Particle Therapy Centre , Delft , The Netherlands
| | - Beth Erickson
- 3 Department of Radiation Oncology, Medical College of Wisconsin , Milwaukee, WI , USA
| | - Onne Reerink
- 4 Department of Radiation Oncology, Isala Clinic , Zwolle , The Netherlands
| | - Martijn Pw Intven
- 1 Department of Radiation Oncology, University Medical Center Utrecht , Utrecht , The Netherlands
| | - Cornelis At van den Berg
- 1 Department of Radiation Oncology, University Medical Center Utrecht , Utrecht , The Netherlands
| | - I Quintus Molenaar
- 5 Department of Surgery, University Medical Center Utrecht , Utrecht , The Netherlands
| | - Frank P Vleggaar
- 6 Department of Gastroenterology, University Medical Center Utrecht , Utrecht , The Netherlands
| | - Gert J Meijer
- 1 Department of Radiation Oncology, University Medical Center Utrecht , Utrecht , The Netherlands
| |
Collapse
|
40
|
Full Modeling of High-Intensity Focused Ultrasound and Thermal Heating in the Kidney Using Realistic Patient Models. IEEE Trans Biomed Eng 2018; 65:969-979. [DOI: 10.1109/tbme.2017.2732684] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
41
|
Tsai YL, Wu CJ, Shaw S, Yu PC, Nien HH, Lui LT. Quantitative analysis of respiration-induced motion of each liver segment with helical computed tomography and 4-dimensional computed tomography. Radiat Oncol 2018; 13:59. [PMID: 29609631 PMCID: PMC5879734 DOI: 10.1186/s13014-018-1007-0] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2017] [Accepted: 03/22/2018] [Indexed: 12/16/2022] Open
Abstract
Background To analyze the respiratory-induced motion of each liver segment using helical computed tomography (helical CT) and 4-dimensional computed tomography (4DCT), and to establish the individual segment expansion margin of internal target volume (ITV) to facilitate target delineation of tumors in different liver segments. Methods Twenty patients who received radiotherapy with CT-simulation scanning of the whole liver in both helical CT and 10-phase-gated 4DCT were investigated, including 2 patients with esophagus cancer, 4 with lung cancer, 10 with breast cancer, 2 with liver cancer, 1 with thymoma, and 1 with gastric diffuse large B-cell lymphoma (DLBCL). For each patient, 9 representative points were drawn on the helical CT images of liver segments 1, 2, 3, 4a, 4b, 5, 6, 7, and 8, respectively, and adaptively deformed to 2 phases of the 4DCT images at the end of inspiration (phase 0 CT) and expiration (phase 50 CT) in the treatment planning system. Using the amplitude of each point between phase 0 CT and phase 50 CT, we established quantitative data for the respiration-induced motion of each liver segment in 3-dimensional directions. Moreover, using the amplitude between the original helical CT and both 4DCT images, we rendered the individual segment expansion margin of ITV for hepatic target delineation to cover more than 95% of each tumor. Results The average amplitude (mean ± standard deviation) was 0.6 ± 3.0 mm in the left-right (LR) direction, 2.3 ± 2.4 mm in the anterior-posterior (AP) direction, and 5.7 ± 3.4 mm in the superior-inferior (SI) direction, respectively. All of the segments moved posteriorly and superiorly during expiration. Segment 7 had the largest amplitude in the SI direction, at 8.6 ± 3.4 mm. Otherwise, the segments over the lateral side, including segments 2, 3, 6, and 7, had greater excursion in the SI direction compared to the medial segments. To cover more than 95% of each tumor, the required expansion margin of ITV in the LR, AP, and SI directions were at least 2.5 mm, 2.5 mm, and 5.0 mm on average, respectively, with variations between different segments. Conclusions The greatest excursion occurred in liver segment 7, followed by the segments over the lateral side in the SI direction. The individual segment expansion margin of ITV is required to delineate targets for each segment and direction.
Collapse
Affiliation(s)
- Yu-Lun Tsai
- Department of Radiation Oncology, Cathay General Hospital, Taipei, Taiwan
| | - Ching-Jung Wu
- Department of Radiation Oncology, Cathay General Hospital, Taipei, Taiwan.,Department of Radiation Oncology, National Defense Medical Center, Taipei, Taiwan.,Department of Biomedical Engineering, I-Shou University, Kaohsiung, Taiwan
| | - Suzun Shaw
- Department of Radiation Oncology, Cathay General Hospital, Taipei, Taiwan
| | - Pei-Chieh Yu
- Department of Radiation Oncology, Cathay General Hospital, Taipei, Taiwan
| | - Hsin-Hua Nien
- Department of Radiation Oncology, Cathay General Hospital, Taipei, Taiwan
| | - Louis Tak Lui
- Department of Radiation Oncology, Cathay General Hospital, Taipei, Taiwan.
| |
Collapse
|
42
|
Walker MD, Bradley KM, McGowan DR. Evaluation of principal component analysis-based data-driven respiratory gating for positron emission tomography. Br J Radiol 2018; 91:20170793. [PMID: 29419327 PMCID: PMC5911393 DOI: 10.1259/bjr.20170793] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Objective: Respiratory motion can degrade PET image quality and lead to inaccurate quantification of lesion uptake. Such motion can be mitigated via respiratory gating. Our objective was to evaluate a data-driven gating (DDG) technique that is being developed commercially for clinical PET/CT. Methods: A data-driven respiratory gating algorithm based on principal component analysis (PCA) was applied to phantom and FDG patient data. An anthropomorphic phantom and a NEMA IEC Body phantom were filled with 18F, placed on a respiratory motion platform, and imaged using a PET/CT scanner. Motion waveforms were measured using an infrared camera [the Real-time Position Management™ system (RPM)] and also extracted from the PET data using the DDG algorithm. The waveforms were compared via calculation of Pearson’s correlation coefficients. PET data were reconstructed using quiescent period gating (QPG) and compared via measurement of recovery percentage and background variability. Results: Data-driven gating had similar performance to the external gating system, with correlation coefficients in excess of 0.97. Phantom and patient images were visually clearer with improved contrast when QPG was applied as compared to no motion compensation. Recovery coefficients in the phantoms were not significantly different between DDG- and RPM-based QPG, but were significantly higher than those found for no motion compensation (p < 0.05). Conclusion: A PCA-based DDG algorithm was evaluated and found to provide a reliable respiratory gating signal in anthropomorphic phantom studies and in example patients. Advances in knowledge: The prototype commercial DDG algorithm may enable reliable respiratory gating in routine clinical PET-CT.
Collapse
Affiliation(s)
- Matthew D Walker
- 1 Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust , Oxford , UK
| | - Kevin M Bradley
- 2 Department of Radiology, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust , Oxford , UK
| | - Daniel R McGowan
- 1 Radiation Physics and Protection, Churchill Hospital, Oxford University Hospitals NHS Foundation Trust , Oxford , UK.,3 Department of Oncology, University of Oxford , Oxford , UK
| |
Collapse
|
43
|
Klawikowski S, Tai A, Ates O, Ahunbay E, Li XA. A fast 4D IMRT/VMAT planning method based on segment aperture morphing. Med Phys 2018; 45:1594-1602. [DOI: 10.1002/mp.12778] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 12/28/2017] [Accepted: 01/02/2018] [Indexed: 12/25/2022] Open
Affiliation(s)
- Slade Klawikowski
- Department of Radiation Oncology; The Medical College of Wisconsin; Milwaukee WI USA
| | - An Tai
- Department of Radiation Oncology; The Medical College of Wisconsin; Milwaukee WI USA
| | - Ozgur Ates
- Department of Radiation Oncology; The Medical College of Wisconsin; Milwaukee WI USA
| | - Ergun Ahunbay
- Department of Radiation Oncology; The Medical College of Wisconsin; Milwaukee WI USA
| | - X. Allen Li
- Department of Radiation Oncology; The Medical College of Wisconsin; Milwaukee WI USA
| |
Collapse
|
44
|
Karava K, Ehrbar S, Riesterer O, Roesch J, Glatz S, Klöck S, Guckenberger M, Tanadini-Lang S. Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer. Radiat Oncol 2017; 12:175. [PMID: 29121945 PMCID: PMC5680781 DOI: 10.1186/s13014-017-0906-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2017] [Accepted: 10/30/2017] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach was performed. The two respiratory motion-management techniques were compared in terms of doses to the target volume and organs at risk. METHODS AND MATERIALS Two volumetric-modulated arc therapy (VMAT) treatment plans (5 × 5 Gy) were created for each of the 12 previously treated pancreatic cancer patients, one using the ITV concept and one the tumor tracking approach. To better evaluate the overall dose delivered to the moving tumor volume, 4D dose calculations were performed on four-dimensional computed tomography (4DCT) scans. The resulting planning target volume (PTV) size for each technique was analyzed. Target and OAR dose parameters were reported and analyzed for both 3D and 4D dose calculation. RESULTS Tumor motion ranged from 1.3 to 11.2 mm. Tracking led to a reduction of PTV size (max. 39.2%) accompanied with significant better tumor coverage (p<0.05, paired Wilcoxon signed rank test) both in 3D and 4D dose calculations and improved organ at risk sparing. Especially for duodenum, stomach and liver, the mean dose was significantly reduced (p<0.05) with tracking for 3D and 4D dose calculations. CONCLUSIONS By using an adaptive tumor tracking approach for respiratory-induced pancreatic motion management, a significant reduction in PTV size can be achieved, which subsequently facilitates treatment planning, and improves organ dose sparing. The dosimetric benefit of tumor tracking is organ and patient-specific.
Collapse
Affiliation(s)
- Konstantina Karava
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland. .,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland.
| | - Stefanie Ehrbar
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland.,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland
| | - Oliver Riesterer
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland.,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland
| | - Johannes Roesch
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland.,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland
| | - Stefan Glatz
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland.,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland
| | - Stephan Klöck
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland.,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland.,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland
| | - Stephanie Tanadini-Lang
- Department of Radiation Oncology, University Hospital Zurich (USZ), Rämistrasse 100, Zurich, 8091, Switzerland.,University of Zurich, Rämistrasse 71, Zurich, 8006, Switzerland
| |
Collapse
|
45
|
Cheesman AR, DiMaio CJ. Role and technique of endoscopic ultrasound placement of fiducial markers in gastrointestinal malignancies. TECHNIQUES IN GASTROINTESTINAL ENDOSCOPY 2017. [DOI: 10.1016/j.tgie.2017.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
46
|
Fujii T, The University of Tokyo, Koizumi N, Kayasuga A, Lee D, Tsukihara H, Fukuda H, Yoshinaka K, Azuma T, Miyazaki H, Sugita N, Numata K, Homma Y, Matsumoto Y, Mitsuishi M, The University of Electro-Communications, Yokohama City University, National Institute of Advanced Industrial Science and Technology. Servoing Performance Enhancement via a Respiratory Organ Motion Prediction Model for a Non-Invasive Ultrasound Theragnostic System. JOURNAL OF ROBOTICS AND MECHATRONICS 2017. [DOI: 10.20965/jrm.2017.p0434] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
[abstFig src='/00290002/15.jpg' width='300' text='Proposed method for tracking and following respiratory organ motion' ] High intensity focused ultrasound (HIFU) is potentially useful for treating stones and/or tumors. With respect to HIFU therapy, it is difficult to focus HIFU on the focal lesion due to respiratory organ motion, and this increases the risk of damaging the surrounding healthy tissues around the target focal lesion. Thus, this study proposes a method to cope with the fore-mentioned problem involving tracking and following the respiratory organ motion via a visual feedback and a prediction model for respiratory organ motion to realize highly accurate servoing performance for focal lesions. The prediction model is continuously updated based on the latest organ motion data. The results indicate that respiratory kidney motion of two healthy subjects is successfully tracked and followed with an accuracy of 0.88 mm by the proposed method and the constructed system.
Collapse
|
47
|
Brandner ED, Chetty IJ, Giaddui TG, Xiao Y, Huq MS. Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology. Med Phys 2017; 44:2595-2612. [PMID: 28317123 DOI: 10.1002/mp.12227] [Citation(s) in RCA: 117] [Impact Index Per Article: 14.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 01/23/2017] [Accepted: 03/10/2017] [Indexed: 12/11/2022] Open
Abstract
The efficacy of stereotactic body radiotherapy (SBRT) has been well demonstrated. However, it presents unique challenges for accurate planning and delivery especially in the lungs and upper abdomen where respiratory motion can be significantly confounding accurate targeting and avoidance of normal tissues. In this paper, we review the current literature on SBRT for lung and upper abdominal tumors with particular emphasis on addressing respiratory motion and its affects. We provide recommendations on strategies to manage motion for different, patient-specific situations. Some of the recommendations will potentially be adopted to guide clinical trial protocols.
Collapse
Affiliation(s)
- Edward D Brandner
- Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC CancerCenter, Pittsburgh, PA, 15232, USA
| | - Indrin J Chetty
- Department of Radiation Oncology, Henry Ford Health System, Detroit, MI, 48202, USA
| | - Tawfik G Giaddui
- Sidney Kimmel Cancer Center, Sidney Kimmel Medical College, Thomas Jefferson University, Philadelphia, PA, 19107, USA
| | - Ying Xiao
- Imaging and Radiation Oncology Core (IROC), University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - M Saiful Huq
- Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC CancerCenter, Pittsburgh, PA, 15232, USA
| |
Collapse
|
48
|
Lee J, Lim DH, Park HC, Yu JI, Choi DW, Choi SH, Heo JS. Predictive factors of gastroduodenal bleeding after postoperative radiotherapy in biliary tract cancer. Jpn J Clin Oncol 2017; 47:328-333. [PMID: 28064203 DOI: 10.1093/jjco/hyw205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 12/22/2016] [Indexed: 12/20/2022] Open
Abstract
Objective To identify predictive factors for gastroduodenal bleeding after postoperative radiation therapy in patients with biliary tract cancer. Methods We identified 186 patients with biliary tract cancer who completed scheduled postoperative radiation therapy from March 2000 to August 2013. To isolate the effects of radiation on gastroduodenal bleeding, patients with pylorus-preserving pancreaticoduodenectomy, pylorus-resecting pancreaticoduodenectomy or Whipple surgery (n = 67) were excluded from this analysis. Postoperative radiation therapy was started at a median 5 weeks (range: 4-12 weeks) after surgery with a median dose of 44 Gy (range: 44-54), and chemotherapy was also concurrently administered to 102 patients. Results The median age of the patients was 59 years (range: 36-76 years). Of the 119 patients, 26 had intrahepatic cholangiocarcinoma, 29 had hilar cholangiocarcinoma, while 64 had extrahepatic tumors (gallbladder cancer, n = 53; proximal bile duct cancer, n = 10; choledochal cyst cancer, n = 1). Of all, 11 patients (9%) developed gastroduodenal bleeding. In univariate analyses, hepatic artery resection and gastroduodenal wall thickening on postoperative radiation therapy simulation computed tomography were statistically significant factors for gastroduodenal bleeding. Multivariate analysis by a logistic regression model using those two variables revealed that both parameters were independent predictors for gastroduodenal bleeding. Conclusions Concomitant hepatic artery resection and presence of gastroduodenal wall thickening on postoperative radiation therapy simulation computed tomography were predictive factors for gastroduodenal bleeding after postoperative radiation therapy in biliary tract cancer. In such cases, patients should be informed of the high risk of gastroduodenal bleeding, and should be closely observed during and after postoperative radiation therapy.
Collapse
Affiliation(s)
- Jieun Lee
- Departments of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Do Hoon Lim
- Departments of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Hee Chul Park
- Departments of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jeong Il Yu
- Departments of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Dong Wook Choi
- Departments of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Seong Ho Choi
- Departments of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jin Seok Heo
- Departments of Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
49
|
Bae JS, Kim DH, Kim WT, Kim YH, Park D, Ki YK. The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy. Radiat Oncol J 2017; 35:65-70. [PMID: 28278561 PMCID: PMC5398350 DOI: 10.3857/roj.2016.02019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2016] [Revised: 12/26/2016] [Accepted: 01/10/2017] [Indexed: 12/25/2022] Open
Abstract
Purpose To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Methods and Materials Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ≤2 cm) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. Results The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Conclusion Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.
Collapse
Affiliation(s)
- Jin Suk Bae
- Department of Radiation Oncology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
| | - Dong Hyun Kim
- Department of Radiation Oncology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.,Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
| | - Won Taek Kim
- Department of Radiation Oncology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.,Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
| | - Yong Ho Kim
- Department of Radiation Oncology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
| | - Dahl Park
- Department of Radiation Oncology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.,Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
| | - Yong Kan Ki
- Department of Radiation Oncology, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea.,Biomedical Research Institute, Pusan National University Hospital, Pusan National University School of Medicine, Busan, Korea
| |
Collapse
|
50
|
Pancreatic tumor motion reduction by use of a custom abdominal corset. PHYSICS & IMAGING IN RADIATION ONCOLOGY 2017. [DOI: 10.1016/j.phro.2017.02.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|