1
|
Shen Z, Min J. Non-equilibrium thermodynamic analysis of coupled heat and moisture transfer across a membrane. Chin J Chem Eng 2022. [DOI: 10.1016/j.cjche.2021.02.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
2
|
Abstract
It is necessary to consider all aspects of environmental factors when assessing the health impact of an eco-building environment on its occupants. However, the multi-criteria and imprecise nature of the indoor-environment in the eco-buildings has caused difficulties in quantifying the indoor environmental pollution level. This paper describes the optimal classification and priority weight methods, which are particularly useful for assessing the indoor environmental quality (IEQ) of an eco-building to demonstrate its innovative applications. The analytic hierarchy process (AHP) was used to set up the strategic decision-making evaluation system for computing the indoor environment index (IEI) risk ranking of eco-buildings. Combined with this, a Microsoft Delphi-based IEQ intelligent forecasting software simulations package was developed, and the innovative application of indoor environmental comprehensive assessment was verified by a case study in Shanghai. The evaluation result was analyzed by the priority weight methods and the AHP decision-making system noted above. This health assessment method and system provides an innovative way for the indoor environment risk evaluation of eco-buildings and is helpful to standardize the local building market.
Collapse
|
3
|
Alabi W, Karoyo AH, Krishnan EN, Dehabadi L, Wilson LD, Simonson CJ. Comparison of the Moisture Adsorption Properties of Starch Particles and Flax Fiber Coatings for Energy Wheel Applications. ACS OMEGA 2020; 5:9529-9539. [PMID: 32363305 PMCID: PMC7191841 DOI: 10.1021/acsomega.0c00762] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Accepted: 03/31/2020] [Indexed: 06/11/2023]
Abstract
The adsorption-desorption behavior of flax fibers (FFs) is reported in this paper. FFs are a potential desiccant material for air-to-air energy wheels, which transfer heat and moisture in building heating, ventilation, and air conditioning (HVAC) systems. The raw FFs sample was subjected to physical modification, followed by complementary material characterization to understand the relationship between its structure and its moisture uptake performance. The surface and textural properties of the modified FFs were determined by gas adsorption (N2, H2O) and gravimetric liquid water swelling studies and further supported by spectroscopic (infrared and scanning electron microscopy) results. A FF-coated small-scale energy exchanger was used to determine the moisture transfer (or latent effectiveness; εl) using single-step and cyclic testing. The FF-coated exchanger had εl values of ∼10 and 40% greater compared to similar exchangers coated with starch particles (SPs) and silica gel (SG) reported in a previous study. The enhanced surface and textural properties, along with the complex compositional structure of FFs and its greater propensity to swell in water, account for the improved performance over SPs. Thus, FFs offer an alternative low-cost, environment-friendly, and sustainable biodesiccant for air-to-air energy wheel applications in buildings. The current study contributes to an improved understanding of the structure-function relationship of biodesiccants for such energy wheel applications.
Collapse
Affiliation(s)
- Wahab
O. Alabi
- Department
of Mechanical Engineering, University of
Saskatchewan, 57 Campus Drive, Saskatoon, Saskatchewan S7N 5A9, Canada
| | - Abdalla H. Karoyo
- Department
of Chemistry, University of Saskatchewan, 110 Science Place—Room 165
Thorvaldson Building, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Easwaran N. Krishnan
- Department
of Mechanical Engineering, University of
Saskatchewan, 57 Campus Drive, Saskatoon, Saskatchewan S7N 5A9, Canada
| | - Leila Dehabadi
- Department
of Chemistry, University of Saskatchewan, 110 Science Place—Room 165
Thorvaldson Building, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Lee D. Wilson
- Department
of Chemistry, University of Saskatchewan, 110 Science Place—Room 165
Thorvaldson Building, Saskatoon, Saskatchewan S7N 5C9, Canada
| | - Carey J. Simonson
- Department
of Mechanical Engineering, University of
Saskatchewan, 57 Campus Drive, Saskatoon, Saskatchewan S7N 5A9, Canada
| |
Collapse
|
4
|
Shakouri M, Krishnan EN, Karoyo AH, Dehabadi L, Wilson LD, Simonson CJ. Water Vapor Adsorption-Desorption Behavior of Surfactant-Coated Starch Particles for Commercial Energy Wheels. ACS OMEGA 2019; 4:14378-14389. [PMID: 31528790 PMCID: PMC6740046 DOI: 10.1021/acsomega.9b00755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 08/05/2019] [Indexed: 05/08/2023]
Abstract
This study reports on the adsorption (dehumidification)-desorption (humidification) behavior of cetylpyridinium bromide (CPB) coated starch particles (SPs), denoted as SP-CPB, as a potential desiccant material for air-to-air energy exchangers. CPB is a cationic surfactant with antibacterial activity that can be used to modify the surface properties of SPs, especially at variable CPB loading levels (SP-CPB0.5, SP-CPB2.5, and SP-CPB5.0, where the numeric suffix represents the synthetic loading level of CPB in mM). The SP-CPB0.5 sample displayed optimal surface area and pore structure properties that was selected for water sorption isotherm studies at 25 °C. The CPB-coated SPs sample (SP-CPB0.5) showed an improved water vapor uptake capacity compared to unmodified starch (SPs) and other desiccant systems such as high amylose starch (HAS15) and silica gel (SG13). Single-step and cyclic water vapor sorption tests were conducted using a small-scale exchanger coated with SP-CPB0.5. The calculated latent effectiveness values obtained from direct measurements using cyclic tests (65.4 ± 2%) agree closely with the estimated latent effectiveness from single-step tests (64.6 ± 2%) at controlled operating conditions. Compared to HAS15- and SG13-coated exchangers, the SP-CPB0.5-coated exchanger performed much better at controlled operating conditions, along with improved longevity due to the CPB surface coating. The presence of CPB did not attenuate the uptake properties of native SPs. Latent effectiveness of SP-CPB0.5-coated exchanger was enhanced (5-30% higher) over that of the SG13- or HAS15-coated exchangers, according to the wheel angular speed. This study reports on a novel and sustainable SP-CPB0.5 material as a promising desiccant coating with tunable uptake and surface properties with potential utility in air-to-air energy exchangers for ventilation systems.
Collapse
Affiliation(s)
- Mohsen Shakouri
- Department
of Mechanical Engineering, University of
Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
- SXRMB
Beamline, Canadian Light Source Inc., 44 Innovation Boulevard, Saskatoon S7N 2V3, Canada
| | - Easwaran N. Krishnan
- Department
of Mechanical Engineering, University of
Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
| | - Abdalla H. Karoyo
- Department
of Chemistry, University of Saskatchewan, 110 Science Place, Saskatoon, SK S7N 5C9, Canada
| | - Leila Dehabadi
- Department
of Chemistry, University of Saskatchewan, 110 Science Place, Saskatoon, SK S7N 5C9, Canada
| | - Lee D. Wilson
- Department
of Chemistry, University of Saskatchewan, 110 Science Place, Saskatoon, SK S7N 5C9, Canada
- E-mail: . Tel: +1-306-966-2961 (L.D.W.)
| | - Carey J. Simonson
- Department
of Mechanical Engineering, University of
Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada
- E-mail: . Tel: +1-306-966-5479 (C.J.S.)
| |
Collapse
|
5
|
Jafarizave M, Khaleghi A, Rezakazemi M. Development of CFD model for membrane-based energy recovery ventilators. Chem Eng Res Des 2019. [DOI: 10.1016/j.cherd.2019.03.019] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
6
|
Engarnevis A, Huizing R, Green S, Rogak S. Heat and mass transfer modeling in enthalpy exchangers using asymmetric composite membranes. J Memb Sci 2018. [DOI: 10.1016/j.memsci.2018.03.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
7
|
Hydrogen-bond acceptance's role in designing room temperature ionic liquid (RTIL) membranes for gas dehumidification, part I: Impacts on permeance and selectivity. J Memb Sci 2017. [DOI: 10.1016/j.memsci.2017.03.026] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
8
|
|
9
|
|
10
|
Huang SM, Zhong Z, Yang M. Conjugate heat and mass transfer in an internally-cooled membrane-based liquid desiccant dehumidifier (IMLDD). J Memb Sci 2016. [DOI: 10.1016/j.memsci.2016.02.026] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
11
|
Ouyang YW, Li ZX, Zhang LZ. Oblique fluid flow and heat transfer across a hollow fiber membrane bank under uniform temperature conditions. J Memb Sci 2014. [DOI: 10.1016/j.memsci.2014.07.070] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
12
|
|
13
|
Liu B, Chen J, Du X, Xue L. Poly (vinyl chloride)/montmorillonite hybrid membranes for total-heat recovery ventilation. J Memb Sci 2013. [DOI: 10.1016/j.memsci.2013.04.046] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
14
|
Huang SM, Zhang LZ, Yang M. Conjugate heat and mass transfer in membrane parallel-plates ducts for liquid desiccant air dehumidification: Effects of the developing entrances. J Memb Sci 2013. [DOI: 10.1016/j.memsci.2013.02.048] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
15
|
|
16
|
Zhang LZ, Zhang XR, Miao QZ, Pei LX. Selective permeation of moisture and VOCs through polymer membranes used in total heat exchangers for indoor air ventilation. INDOOR AIR 2012; 22:321-330. [PMID: 22145748 DOI: 10.1111/j.1600-0668.2011.00762.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
UNLABELLED Fresh air ventilation is central to indoor environmental control. Total heat exchangers can be key equipment for energy conservation in ventilation. Membranes have been used for total heat exchangers for more than a decade. Much effort has been spent to achieve water vapor permeability of various membranes; however, relatively little attention has been paid to the selectivity of moisture compared with volatile organic compounds (VOCs) through such membranes. In this investigation, the most commonly used membranes, both hydrophilic and hydrophobic ones, are tested for their permeability for moisture and five VOCs (acetic acid, formaldehyde, acetaldehyde, toluene, and ethane). The selectivity of moisture vs. VOCs in these membranes is then evaluated. With a solution-diffusion model, the solubility and diffusivity of moisture and VOCs in these membranes are calculated. The resulting data could provide some reference for future material selection. PRACTICAL IMPLICATIONS Total heat exchangers are important equipment for fresh air ventilation with energy conservation. However, their implications for indoor air quality in terms of volatile organic compound permeation have not been known. The data in this article help us to clarify the impacts on indoor VOC levels of membrane-based heat exchangers. Guidelines for material selection can be obtained for future use total heat exchangers for building ventilation.
Collapse
Affiliation(s)
- L-Z Zhang
- Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou, China.
| | | | | | | |
Collapse
|
17
|
|
18
|
|
19
|
Min J, Wang L. Membrane sorption property effects on transmembrane permeation. CHINESE SCIENCE BULLETIN-CHINESE 2011. [DOI: 10.1007/s11434-011-4562-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
20
|
Studies of the process of moisture exchange across a membrane using irreversible thermodynamics. CHINESE SCIENCE BULLETIN-CHINESE 2011. [DOI: 10.1007/s11434-010-4238-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
21
|
Min J, Hu T, Song Y. Experimental and numerical investigations of moisture permeation through membranes. J Memb Sci 2011. [DOI: 10.1016/j.memsci.2010.10.064] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
22
|
Zhang XR, Zhang LZ, Liu HM, Pei LX. One-step fabrication and analysis of an asymmetric cellulose acetate membrane for heat and moisture recovery. J Memb Sci 2011. [DOI: 10.1016/j.memsci.2010.09.054] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
23
|
Zhang LZ. An analytical solution for heat mass transfer in a hollow fiber membrane based air-to-air heat mass exchanger. J Memb Sci 2010. [DOI: 10.1016/j.memsci.2010.05.015] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
24
|
Analysis of the effects of mass transfer on heat transfer in the process of moisture exchange across a membrane. CHINESE SCIENCE BULLETIN-CHINESE 2010. [DOI: 10.1007/s11434-009-0361-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
25
|
Performance analysis of a membrane-based enthalpy exchanger: Effects of the membrane properties on the exchanger performance. J Memb Sci 2010. [DOI: 10.1016/j.memsci.2009.11.032] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
26
|
|
27
|
Zhang L, Zhu D, Deng X, Hua B. Thermodynamic modeling of a novel air dehumidification system. ENERGY AND BUILDINGS 2005; 37:279-286. [PMID: 32288121 PMCID: PMC7126610 DOI: 10.1016/j.enbuild.2004.06.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 06/18/2004] [Indexed: 06/11/2023]
Abstract
A novel air dehumidification system is proposed. The proposed system incorporates a membrane-based total heat exchanger into a mechanical air dehumidification system, where the fresh air flows through the enthalpy exchanger, the evaporator and the condenser subsequently. Thermodynamic model for the performance estimation of the combined system is investigated. Processes of the fresh air and the refrigerant are studied. Two additional specific programs are devised to calculate the psychrometrics and the thermodynamic properties of the refrigerant R134a. Annual energy requirement is 4.15 × 106 kJ per person, or 33% saving from a system without energy saving measures.
Collapse
Affiliation(s)
- L.Z. Zhang
- Corresponding author. Tel.: +86 20 87114268; fax: +86 20 87112487.
| | | | | | | |
Collapse
|
28
|
|