1
|
Dugheri S, Mucci N, Bonari A, Marrubini G, Cappelli G, Ubiali D, Campagna M, Montalti M, Arcangeli G. Liquid phase microextraction techniques combined with chromatography analysis: a review. ACTA CHROMATOGR 2020. [DOI: 10.1556/1326.2019.00636] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Sample pretreatment is the first and the most important step of an analytical procedure. In routine analysis, liquid–liquid microextraction (LLE) is the most widely used sample pre-treatment technique, whose goal is to isolate the target analytes, provide enrichment, with cleanup to lower the chemical noise, and enhance the signal. The use of extensive volumes of hazardous organic solvents and production of large amounts of waste make LLE procedures unsuitable for modern, highly automated laboratories, expensive, and environmentally unfriendly. In the past two decades, liquid-phase microextraction (LPME) was introduced to overcome these drawbacks. Thanks to the need of only a few microliters of extraction solvent, LPME techniques have been widely adopted by the scientific community. The aim of this review is to report on the state-of-the-art LPME techniques used in gas and liquid chromatography. Attention was paid to the classification of the LPME operating modes, to the historical contextualization of LPME applications, and to the advantages of microextraction in methods respecting the value of green analytical chemistry. Technical aspects such as description of methodology selected in method development for routine use, specific variants of LPME developed for complex matrices, derivatization, and enrichment techniques are also discussed.
Collapse
Affiliation(s)
- Stefano Dugheri
- 1 Industrial Hygiene and Toxicology Laboratory, Careggi University Hospital, Florence, Italy
| | - Nicola Mucci
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Alessandro Bonari
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | | | - Giovanni Cappelli
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Daniela Ubiali
- 3 Department of Drug Sciences, University of Pavia, Pavia, Italy
| | - Marcello Campagna
- 4 Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Manfredi Montalti
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Giulio Arcangeli
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| |
Collapse
|
2
|
Bahrami A, Ghamari F, Yamini Y, Ghorbani Shahna F, Koolivand A. Ion-pair-based hollow-fiber liquid-phase microextraction combined with high-performance liquid chromatography for the simultaneous determination of urinary benzene, toluene, and styrene metabolites. J Sep Sci 2017; 41:501-508. [DOI: 10.1002/jssc.201700685] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2017] [Revised: 10/21/2017] [Accepted: 10/22/2017] [Indexed: 01/31/2023]
Affiliation(s)
- Abdulrahman Bahrami
- Center of Excellence for Occupational Health; Occupational Health and Safety Research Center; School of Public health; Hamadan University of Medical Sciences; Hamadan Iran
| | - Farhad Ghamari
- Department of Occupational Health Engineering; Faculty of Health; Arak University of Medical Sciences; Arak Iran
| | - Yadollah Yamini
- Department of Chemistry; Faculty of Sciences; Tarbiat Modares University; Tehran Iran
| | - Farshid Ghorbani Shahna
- Center of Excellence for Occupational Health; Occupational Health and Safety Research Center; School of Public health; Hamadan University of Medical Sciences; Hamadan Iran
| | - Ali Koolivand
- Department of Environmental Health Engineering; Faculty of Health; Arak University of Medical Sciences; Arak Iran
| |
Collapse
|
3
|
Ghamari F, Bahrami A, Yamini Y, Shahna FG, Moghimbeigi A. Development of Hollow-Fiber Liquid-Phase Microextraction Method for Determination of Urinary trans,trans-Muconic Acid as a Biomarker of Benzene Exposure. ANALYTICAL CHEMISTRY INSIGHTS 2016; 11:65-71. [PMID: 27660405 PMCID: PMC5019127 DOI: 10.4137/aci.s40177] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Revised: 07/10/2016] [Accepted: 07/31/2016] [Indexed: 11/11/2022]
Abstract
For the first time, hollow-fiber liquid-phase microextraction combined with high-performance liquid chromatography–ultraviolet was used to extract trans,trans-muconic acid, in urine samples of workers who had been exposed to benzene. The parameters affecting the metabolite extraction were optimized as follows: the volume of sample solution was 11 mL with pH 2, liquid membrane containing dihexyl ether as the supporter, 15% (w/v) of trioctylphosphine oxide as the carrier, the time of extraction was 120 minutes, and stirring rate was 500 rpm. Organic phase impregnated in the pores of a hollow fiber was extracted into 24 µL solution of 0.05 mol L−1 Na2CO3 located inside the lumen of the fiber. Under optimized conditions, a high enrichment factor of 153–182 folds, relative recovery of 83%–92%, and detection limit of 0.001 µg mL−1 were obtained. The method was successfully applied to the analysis of ttMA in real urine samples.
Collapse
Affiliation(s)
- Farhad Ghamari
- Excellence Centre of Occupational Health, Research Center for Health Sciences, School of Public Health, Hamedan University of Medical Sciences, Hamedan, Iran
| | - Abdulrahman Bahrami
- Excellence Centre of Occupational Health, Research Center for Health Sciences, School of Public Health, Hamedan University of Medical Sciences, Hamedan, Iran
| | - Yadollah Yamini
- Chemistry Professor, Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, Tehran, Iran
| | - Farshid Ghorbani Shahna
- Excellence Centre of Occupational Health, Research Center for Health Sciences, School of Public Health, Hamedan University of Medical Sciences, Hamedan, Iran
| | - Abbas Moghimbeigi
- Department of Biostatistics and Epidemiology, School of Public Health and Center of Health Research, Hamedan University of Medical Sciences, Hamedan, Iran
| |
Collapse
|
4
|
Marrubini G, Appelblad P, Gazzani G, Papetti A. Determination of free quinic acid in food matrices by Hydrophilic Interaction Liquid Chromatography with UV detection. J Food Compost Anal 2015. [DOI: 10.1016/j.jfca.2015.06.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
5
|
Yang SH, Fan H, Classon RJ, Schug KA. Restricted access media as a streamlined approach toward on-line sample preparation: Recent advancements and applications. J Sep Sci 2013; 36:2922-38. [DOI: 10.1002/jssc.201300595] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2013] [Revised: 06/16/2013] [Accepted: 06/21/2013] [Indexed: 01/22/2023]
Affiliation(s)
- Samuel H. Yang
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| | - Hui Fan
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| | | | - Kevin A. Schug
- Department of Chemistry and Biochemistry; The University of Texas at Arlington; Arlington TX USA
| |
Collapse
|
6
|
Cassiano NM, Lima VV, Oliveira RV, de Pietro AC, Cass QB. Development of restricted-access media supports and their application to the direct analysis of biological fluid samples via high-performance liquid chromatography. Anal Bioanal Chem 2006; 384:1462-9. [PMID: 16800052 DOI: 10.1007/s00216-005-0253-9] [Citation(s) in RCA: 82] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A quick overview of published methods for analyzing compounds in complex biological samples reveals that the most difficult step is the clean-up or extraction of a required compound from the matrix. The strategy required to analyze exogenous compounds in biological fluids depends greatly upon the nature of the compound and upon the biomatrix. Coupled-column separation using restricted-access media as the first dimension in order to exclude macromolecules and retain micromolecules has been successfully used for a number of biological fluids. This paper presents the history of the development of restricted-access media supports and of their application to the direct injection of biological fluid samples in high-performance liquid chromatography.
Collapse
Affiliation(s)
- N M Cassiano
- Departamento de Química, Universidade Federal de São Carlos, Cx. Postal 676, São Carlos, SP, 13565-905, Brazil
| | | | | | | | | |
Collapse
|
7
|
Lin LC, Chiung YM, Shih JF, Shih TS, Liao PC. Validation of an online dual-loop cleanup device with an electrospray ionization tandem mass spectrometry-based system for simultaneous quantitative analysis of urinary benzene exposure biomarkers trans, trans-muconic acid and S-phenylmercapturic acid. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2005.08.075] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
8
|
Zheng Y, Xu G, Yang J, Zhao X, Pang T, Kong H. Determination of urinary nucleosides by direct injection and coupled-column high-performance liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2005; 819:85-90. [PMID: 15797525 DOI: 10.1016/j.jchromb.2005.01.033] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2004] [Accepted: 01/31/2005] [Indexed: 11/20/2022]
Abstract
A coupled-column liquid chromatographic method for the direct analysis of 14 urinary nucleosides is described. Efficient on-line clean-up and concentration of 14 nucleosides from urine samples were obtained by using a boronic acid-substituted silica column (40 mm x 4.0 mm I.D.) as the first column (Col-1) and a Hypersil ODS2 column (250 mm x 4.6 mm I.D.) as the second column (Col-2). The mobile phases applied consisted of 0.25 mol/L ammonium acetate (pH 8.5) on Col-1, and of 25 mmol/L potassium dihydrogen phosphate (pH 4.5) on Col-2, respectively. Determination of urinary nucleosides was performed on Col-2 column by using a linear gradient elution comprising 25 mmol/L potassium dihydrogen phosphate (pH 4.5) and methanol-water (60:40, v/v) with UV detection at 260 nm. Urinary nucleosides analysis can be carried out by this procedure in 50 min requiring only pH adjustment and the protein precipitation by centrifugation of urine samples. Calibration plots of 14 standard nucleosides showed excellent linearity (r > 0.995) and the limits of detection were at micromolar levels. Both of intra- and inter-day precisions of the method were better than 6.6% for direct determination of 14 nucleosides. The validated method was applied to quantify 14 nucleosides in 20 normal urines to establish reference ranges.
Collapse
Affiliation(s)
- Yufang Zheng
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, the Chinese Academy of Sciences, Dalian 116023, China
| | | | | | | | | | | |
Collapse
|
9
|
Lin LC, Shih JF, Shih TS, Li YJ, Liao PC. An electrospray ionization tandem mass spectrometry based system with an online dual-loop cleanup device for simultaneous quantitation of urinary benzene exposure biomarkers trans,trans-muconic acid and S-phenylmercapturic acid. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2004; 18:2743-2752. [PMID: 15499662 DOI: 10.1002/rcm.1687] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) system with an online dual-loop cleanup device was developed for simultaneous quantitation of the urinary benzene exposure biomarkers trans,trans-muconic acid (ttMA) and S-phenylmercapturic acid (SPMA). The cleanup device was constructed from an autosampler, two electrically operated two-position switching valves, a reversed-phase C18 trap cartridge, a 200-microL loop, and two solvent-delivery pumps. The device was interfaced directly with a triple-quadrupole mass spectrometer and fully controlled by computer software and hardware. Because isotope dilution by introducing 13C-labeled ttMA and SPMA as internal standards was employed, the precision of the analytical system was high (for ttMA, intra- and inter-day CV values ranged from 3.82-4.53%; for SPMA, 2.13-7.06%). The calibration curves obtained using human urine spiked with ttMA were linear from 15.6-4000 microg/L (R = 0.9998) and SPMA at concentrations from 0.78-200 microg/L (R = 0.9993). The method detection limit (MDL) for SPMA was 0.23 microg/L. The MDL of ttMA could not be determined accurately because of unavailability of an appropriate blank urine matrix, but was estimated to be lower than 7.43 microg/L. Without tedious manual sample cleanup procedures the analytical system is fully automated and is therefore useful for high-throughput simultaneous determination of urinary ttMA and SPMA. The sample throughput is roughly 100 samples per day. With the selectivity and the sensitivity provided by MS/MS detection, the analytical system can be used for large-scale monitoring of environmental or occupational exposure of humans to benzene.
Collapse
Affiliation(s)
- Lung-Cheng Lin
- Department of Environmental and Occupational Health, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan
| | | | | | | | | |
Collapse
|
10
|
Marrubini G, Coccini T, Maestri L, Manzo L. Effect of sorbic acid administration on urinary trans,trans-muconic acid excretion in rats exposed to low levels of benzene. Food Chem Toxicol 2002; 40:1799-806. [PMID: 12419694 DOI: 10.1016/s0278-6915(02)00185-0] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Trans,trans-muconic acid (t,t-MA) is a biomarker of benzene exposure reflecting metabolic activation to trans,trans-muconaldehyde. t,t-MA background urinary levels are highly variable, thus limiting its use to exposure monitoring of levels over 1 ppm of benzene. Actually, sorbic acid (SA) is known to influence background excretion of t,t-MA in man, but only a few examples suggest that SA ingestion can enhance t,t-MA levels occurring together with benzene exposure. In this study, the effect of SA was investigated in benzene-exposed male Sprague-Dawley rats exposed to 1 ppm benzene for 6 h. Exposed animals had a 24-h urinary t,t-MA excretion higher than that observed in non-exposed animals (87+/-13 microg/kg vs 19+/-3 microg/kg body weight). The oral dose of 8 mg/kg body weight SA had no effect on urinary t,t-MA both in control and in benzene-exposed rats. Increases of t,t-MA levels in urine occurred at SA doses of 50-200 mg/kg body weight, and co-exposure to benzene and SA (50 and 100 mg/kg body weight) produced additive enhancement of t,t-MA excretion. These data demonstrate the dose-response relationship between SA administration and t,t-MA excretion. Our study showed that SA ingestion at doses equal to or greater than 50 mg/kg body weight significantly affects the t,t-MA urinary levels in rats exposed to 1 ppm of benzene for 6 h. These data support the conclusion that in man t,t-MA is not suitable for biomonitoring of low levels of benzene exposure.
Collapse
Affiliation(s)
- G Marrubini
- Laboratory for Pharmacokinetics and Analytical Toxicology, Clinical Toxicology Division, Department of Internal Medicine, University of Pavia, Via Brodolini 7, 27028 San Martino Siccomario, Italy.
| | | | | | | |
Collapse
|
11
|
Marrubini G, Coccini T, Manzo L. Direct analysis of urinary trans,trans-muconic acid by coupled column liquid chromatography and spectrophotometric ultraviolet detection: method applicability to human urine. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 758:295-303. [PMID: 11486840 DOI: 10.1016/s0378-4347(01)00194-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A coupled column liquid chromatographic (LC-LC) method for the direct analysis in human urine of the ring opened benzene metabolite, trans,trans-muconic acid (t,t-MA) is described. The method was tested using urine samples collected from five refinery workers exposed to concentrations of airborne benzene (0.2-0.5 ppm), and from non-exposed volunteers. The analytical columns used were of 50 x 4.6 mm I.D. packed with 3 microm p.s. Microspher C18 material as the first column (C-1), and a 100 x 4.6 mm I.D. column packed with 3 microm p.s. Hypersil ODS material as the second one (C-2). The mobile phases applied consisted, respectively, of methanol-0.074% trifluoroacetic acid (TFA) in water (4:96, v/v) on C-1, and of methanol-0.074% TFA in water (10:90, v/v) on C-2. Under these conditions t,t-MA eluted 15 min after injection. The present method, coupling the LC-LC technique with UV detection at 264 nm, permits the quantitation of t,t-MA directly in urine at levels as low as 0.05 mg/l. The determination is performed with a sample throughput of 2 h(-1) requiring only pH adjustment and centrifugation of the sample. Calibration plots of standard additions of t,t-MA to pooled urine taken from five non-exposed subjects were linear (r>0.999) over a wide concentration range (0.05, 0.1, 0.5, 1.0, 2.0 mg/l). The precision of the method (RSD) was in the range of 0.5 to 3.8%, and the within-session repeatability on workers urine samples (levels 0.06, 0.1, 0.2, 1.0 mg/l) was in the range of 3 to 8%. The present method improves the applicability of routine t,t-MA analysis, where it is most desirable that a large number of biological samples can be processed automatically or with minimal human labour, at low cost, and with a convenient turn-around time.
Collapse
Affiliation(s)
- G Marrubini
- Department of Internal Medicine, University of Pavia, Italy.
| | | | | |
Collapse
|