1
|
Matias VA, Weber AG, Gueretz JS, Walz GC, Tagliari-Corrêa CV, Toumi H, Férard JF, Radetski CM, Somensi CA, Cotelle S. An alternative approach to assess ecotoxicological effects of agrochemical combinations used in Brazilian aquaculture farms. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023:10.1007/s11356-023-27414-2. [PMID: 37155099 DOI: 10.1007/s11356-023-27414-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 04/30/2023] [Indexed: 05/10/2023]
Abstract
Agrochemicals used for treating and preventing aquaculture diseases are usually present in combination with other compounds, and the toxicity resulting from their chemical interactions presents an important reason to assess the ecotoxicity of compound mixtures in view to better understanding the joint action of chemicals and avoiding their environmental impacts. In this study, we evaluated the acute aquatic ecotoxicity of several compounds used in Brazilian fish farming (Oxytetracycline [OXT], Trichlorfon [TRC], and BioFish® [BIO]), both individually and in binary and ternary mixtures. Initial test concentrations were prepared according to the recommended concentrations for aquaculture application, and from these, a geometric dilution series was tested on two important fresh water quality indicator species, the microcrustacean Daphnia magna and the bacterium Aliivibrio fischeri. At the recommended pond application rate, TRC and BIO applied individually showed toxicity to the tested organisms in terms of the lowest-observed-effect concentration (LOEC), and D. magna was always more sensitive than A. fischeri. For the two test organisms, the results obtained with the binary mixtures showed that the TRC and BIO mixture was more toxic than TRC and OXT, which in turn was more toxic than OXT and BIO. The toxicity from all agrochemicals in the ternary mixture was more than that of the agrochemical combinations in the binary mixtures. Given the results presented in this study, it is evident that the mode of action and availability of the tested compounds undergo changes that increase toxicity when they are present in combination, and therefore, aquaculture wastewater treatment should be adopted to ensure decontamination of agrochemical residues.
Collapse
Affiliation(s)
- Vanessa A Matias
- Laboratório de Química Analítica e Ambiental, Instituto Federal Catarinense - Campus Araquari, Araquari, SC, 89245-000, Brazil
- Laboratório de Fisiologia, Universidade do Vale do Itajaí, Itajaí, SC, 88302-202, Brazil
| | - Ariana G Weber
- Laboratório de Fisiologia, Universidade do Vale do Itajaí, Itajaí, SC, 88302-202, Brazil
| | - Juliano S Gueretz
- Laboratório de Química Analítica e Ambiental, Instituto Federal Catarinense - Campus Araquari, Araquari, SC, 89245-000, Brazil
| | - Gabriel C Walz
- Curso de Mestrado em Tecnologia e Ambiente, Instituto Federal Catarinense - Campus Araquari, Araquari, SC, 89245-000, Brazil
| | - Cristiane V Tagliari-Corrêa
- Curso de Mestrado em Tecnologia e Ambiente, Instituto Federal Catarinense - Campus Araquari, Araquari, SC, 89245-000, Brazil
| | - Héla Toumi
- Faculté des Sciences de Bizerte, Laboratoire de Bio-surveillance de l'Environnement (LBE), Université de Carthage, 7021, Zarzouna, Bizerte, Tunisia
| | - Jean-François Férard
- Laboratoire Interdisciplinaire des Environnements Continentaux (LIEC), Université de Lorraine, F-57070, Metz, France
| | - Claudemir M Radetski
- Programa de Pós-Graduação em Ciência e Tecnologia Ambiental, Universidade do Vale do Itajaí, Itajaí, SC, 88302-202, Brazil
| | - Cleder A Somensi
- Laboratório de Química Analítica e Ambiental, Instituto Federal Catarinense - Campus Araquari, Araquari, SC, 89245-000, Brazil
- Curso de Mestrado em Tecnologia e Ambiente, Instituto Federal Catarinense - Campus Araquari, Araquari, SC, 89245-000, Brazil
| | - Sylvie Cotelle
- Laboratoire Interdisciplinaire des Environnements Continentaux (LIEC), Université de Lorraine, F-57070, Metz, France.
| |
Collapse
|
2
|
Cai ZF, Li HY, Wang XS, Min C, Wen JQ, Fu RX, Dai ZY, Chen J, Guo MZ, Yang HJ, Bai PP, Lu XM, Wu T, Wu Y. Highly luminescent copper nanoclusters as temperature sensors and “turn off” detection of oxytetracycline. Colloids Surf A Physicochem Eng Asp 2022. [DOI: 10.1016/j.colsurfa.2022.129202] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
3
|
Venkatesan K, Haider N, Yusuf M, Hussain A, Afzal O, Yasmin S, Altamimi AS. Water/transcutol/lecithin/M−812 green cationic nanoemulsion to treat oxytetracycline contaminated aqueous bulk solution. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119154] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
4
|
Chemometric-assisted kinetic determination of oxytetracycline using AgInS 2 quantum dots as PL sensing platforms. Anal Chim Acta 2021; 1188:339174. [PMID: 34794564 DOI: 10.1016/j.aca.2021.339174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2021] [Revised: 09/16/2021] [Accepted: 10/12/2021] [Indexed: 12/27/2022]
Abstract
In this work a kinetic fluorometric methodology relying on the time-based monitoring of the photoluminescence quenching of AgInS2 ternary quantum dots induced by oxytetracycline, was developed. The kinetic approach allowed not only to reduce the LOD and improve sensitivity and selectivity but also to collect second-order data that was explored for the quantification of the target analyte in the presence of uncalibrated interfering species. Upon processing the acquired second-order kinetic PL data by unfolded partial least-squares (U-PLS), oxytetracycline was quantified in commercially available pharmaceutical formulations. The obtained results, namely an R2P higher than 0.99 and RE lower than 8%, proved the suitability and accuracy of the developed approach.
Collapse
|
5
|
Peng B, Zhang Z, Tang L, Ouyang X, Zhu X, Chen L, Fan X, Zhou Z, Wang J. Self-Powered Photoelectrochemical Aptasensor for Oxytetracycline Cathodic Detection Based on a Dual Z-Scheme WO 3/g-C 3N 4/MnO 2 Photoanode. Anal Chem 2021; 93:9129-9138. [PMID: 34152736 DOI: 10.1021/acs.analchem.1c00929] [Citation(s) in RCA: 39] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
With the high sensitivity and anti-interference provided by a dual Z-scheme structure photoanode and a two-electrode system, a high-performance self-powered photoelectrochemical (PEC) aptasensor for oxytetracycline (OTC) detection was established in this work. Graphitic carbon nitride (g-C3N4) with excellent photoelectric properties was used to be combined with WO3 and MnO2 to form a kind of dual Z-scheme heterojunction. The designed unique structure and the complementary performances of the three materials collectively guaranteed the highly stable photocurrent output of the photoanode due to the wide range of light absorption and the high separation rate of electron-hole pairs. The aptamer-based cathode modified with reduced graphene oxide (rGO) and Au nanoparticles (Au NPs) provided high conductivity and aptamer-binding sites, which brought excellent selective recognition of OTC as well as the self-powered capacity by receiving electrons from the photoanode. In the PEC sensing of OTC, the device presented a wide detection range from 1 pM to 150 nM and a low detection limit of 0.1 pM. Besides, the developed PEC aptasenor showed good selectivity, reproducibility, and stability, so as to be applied to real samples. The proposed PEC sensing method can be considered an effective and promising direction for the detection of antibiotics in the future.
Collapse
Affiliation(s)
- Bo Peng
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Ziling Zhang
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Lin Tang
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Xilian Ouyang
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Xu Zhu
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Li Chen
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Xinya Fan
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Zheping Zhou
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| | - Jiajia Wang
- College of Environmental Science and Engineering, Hunan University, Changsha 410082, China.,Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
| |
Collapse
|
6
|
Wang W, Xu Y, Liu X, Peng L, Huang T, Yan Y, Li C. Efficient fabrication of ratiometric fluorescence imprinting sensors based on organic-inorganic composite materials and highly sensitive detection of oxytetracycline in milk. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105053] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
7
|
Sebaiy MM, Hassan WS, Elhennawy ME. Developing a High-Performance Liquid Chromatography (HPLC) Method for Simultaneous Determination of Oxytetracycline, Tinidazole and Esomeprazole in Human Plasma. J Chromatogr Sci 2019; 57:724-729. [DOI: 10.1093/chromsci/bmz046] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2018] [Revised: 04/30/2019] [Accepted: 05/17/2019] [Indexed: 11/12/2022]
Abstract
Abstract
A high performance liquid chromatography method had been developed and validated for rapid simultaneous separation and determination of three anti-helicobacter drugs, oxytetracycline (OXY), tinidazole (TIN) and esomeprazole (ESM) in human plasma within 6 minutes. Drugs extraction method from plasma was based on protein precipitation technique. Separation was carried out on a Equisil BDS C18 column (5 μm, 150 × 4.60 mm) using a mobile phase of acetonitrile: 0.025 M KH2PO4 (25: 75, v/v) adjusted to pH 3.50 with ortho-phosphoric acid at ambient temperature. The flow rate was 1 mL/min and maximum absorption was measured using Diode Array (DAD) detector at 285 nm. The retention times of OXY, TIN and ESM were recorded to be 2.68, 3.52 and 5.17 minutes, respectively, indicating a shorter analysis time. Limits of detection were also reported to be 0.10, 0.07 and 0.04 μg/mL for OXY, TIN and ESM, respectively, showing a high degree of the method sensitivity. The method was then validated according to FDA guidelines for the determination of the drugs clinically in human plasma specially regarding pharmacokinetic and bioequivalence studies.
Collapse
Affiliation(s)
- Mahmoud M Sebaiy
- Department of Medicinal Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt
| | - Wafaa S Hassan
- Department of Analytical Chemistry, Faculty of Pharmacy, Zagazig University, Zagazig 44519, Egypt
| | - Mostafa E Elhennawy
- Department of Chemistry, Faculty of Science, Zagazig University, Zagazig 44519, Egypt
| |
Collapse
|
8
|
Simultaneous quantification of antibiotics in wastewater from pig farms by capillary electrophoresis. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1092:386-393. [DOI: 10.1016/j.jchromb.2018.06.017] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2017] [Revised: 06/05/2018] [Accepted: 06/06/2018] [Indexed: 12/16/2022]
|
9
|
Sversut RA, da Silva AA, Cardoso TFM, Kassab NM, do Amaral MS, Salgado HRN. A Critical Review of Properties and Analytical Methods for the Determination of Oxytetracyline in Biological and Pharmaceutical Matrices. Crit Rev Anal Chem 2016; 47:154-171. [PMID: 27650368 DOI: 10.1080/10408347.2016.1236673] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Antibiotics have an unquestionable importance in the treatment of many infections. Oxytetracycline is an antibiotic belonging to the class of tetracyclines, available for use in human and veterinary medicine. Development of analytical methods that prove the quality and efficacy of these drugs is fundamentally important to the pharmaceutical industry. In this context, the research presents an overview of the analytical profile of oxytetracycline, describing its chemical and pharmacological properties, and analytical methods for quantification of this drug in biological samples and pharmaceutical products. Oxytetracycline can be analyzed in these matrices by many types of methodologies. However, high-performance liquid chromatography is the most widely used, being recommended by official compendia. This kind of study can be useful to support the development of new efficient and sustainable analytical methods that may be utilized in the quality control routine of oxytetracycline in pharmaceutical products and pharmacokinetic monitoring in biological samples.
Collapse
Affiliation(s)
- Rúbia Adrieli Sversut
- a Department of Pharmaceuticals , School of Pharmaceutical Sciences, São Paulo State University , Araraquara, São Paulo , Brazil
| | - Adriane Andrade da Silva
- b Center of Biological and Health Sciences, Pharmacy Course, Federal University of Mato Grosso do Sul , Campo Grande-MS , Brazil
| | - Teófilo Fernando Mazon Cardoso
- b Center of Biological and Health Sciences, Pharmacy Course, Federal University of Mato Grosso do Sul , Campo Grande-MS , Brazil
| | - Nájla Mohamad Kassab
- b Center of Biological and Health Sciences, Pharmacy Course, Federal University of Mato Grosso do Sul , Campo Grande-MS , Brazil
| | | | - Hérida Regina Nunes Salgado
- a Department of Pharmaceuticals , School of Pharmaceutical Sciences, São Paulo State University , Araraquara, São Paulo , Brazil
| |
Collapse
|
10
|
Gao C, Liu Z, Chen J, Yan Z. A novel fluorescent assay for oxytetracycline hydrochloride based on fluorescence quenching of water-soluble CdTe nanocrystals. LUMINESCENCE 2012; 28:378-83. [DOI: 10.1002/bio.2393] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Revised: 03/11/2012] [Accepted: 05/15/2012] [Indexed: 11/06/2022]
Affiliation(s)
| | - Zhen Liu
- Department of Analytical Chemistry; China Pharmaceutical University; Nanjing; 210009; China
| | | | | |
Collapse
|
11
|
Assessment of topical bioequivalence using dermal microdialysis and tape stripping methods. Pharm Res 2011; 28:2165-75. [PMID: 21499834 DOI: 10.1007/s11095-011-0444-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2011] [Accepted: 03/28/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE To assess the bioequivalence of two commercial topical formulations of oxytetracycline HCl by tape stripping and microdialysis in healthy volunteers. METHODS Tape stripping study was conducted on 12 healthy volunteers. After a 30-minute application of the formulations, adhesive tapes were used to sample stratum corneum at 0.25, 0.5, 1, 1.5, 2, 3, 4 hr. Ten of these volunteers were included in the microdialysis study with a period of 4 weeks between the experiments. Microdialysis probes were inserted into the dermis of the forearm. Following the application of the test and reference simultaneously, dialysates were collected in 30-minute sampling intervals up to 4 hr. RESULTS Pharmacokinetic evaluation by microdialysis yielded that the test could not be said to be bioequivalent to the reference at 90% CI. The intersubject variability of oxytetracycline content in stratum corneum was moderate when it was compared to the dermal levels. The test was found to be bioequivalent to reference according to the dermatopharmacokinetic evaluation by tape stripping. CONCLUSIONS No significant correlations were found between microdialysis and tape stripping methods as regarding the topical bioequivalence of oxytetracycline HCl formulations.
Collapse
|
12
|
Kim K, Gu MB, Kang DH, Park JW, Song IH, Jung HS, Suh KY. High-sensitivity detection of oxytetracycline using light scattering agglutination assay with aptasensor. Electrophoresis 2010; 31:3115-20. [PMID: 20872613 DOI: 10.1002/elps.201000217] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We present an aptamer-based biosensor (aptasensor) for rapid and high-sensitive detection of oxytetracycline (OTC) antibiotic in PBS inside a Y-channel PDMS microfluidic device. The detection was made by real-time monitoring of the agglutination assay of ssDNA aptamer-conjugated polystyrene latex microspheres with proximity optical fibers. The agglutination assay was performed with serially diluted OTC antibiotic solutions using highly carboxylated polystyrene particles of 920 nm diameter conjugated with OTC-binding ssDNA aptamer. Proximity optical fibers were used to measure the increase in 45° forward light scattering of the aggregated particles by fixing them around the viewing cell of the device with stable angle and distance to the detector. The detection limit was around 100 ppb for the current aptasensor system with the detection time less than 3 min.
Collapse
Affiliation(s)
- Keesung Kim
- School of Mechanical and Aerospace Engineering, Seoul National University, Seoul, Republic of Korea
| | | | | | | | | | | | | |
Collapse
|
13
|
Enhancement of oxytetracycline production after gamma irradiation-induced mutagenesis of Streptomyces rimosus CN08 strain. World J Microbiol Biotechnol 2010; 26:1317-22. [PMID: 24026936 DOI: 10.1007/s11274-009-0303-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2009] [Accepted: 12/30/2009] [Indexed: 10/20/2022]
Abstract
Streptomyces rimosus CN08 isolated from Tunisian soil produced 8.6 mg l(-1) of oxytetracycline (OTC) under submerged fermentation (SmF). Attempts were made for enhancing OTC production after irradiation-induced mutagenesis of Streptomyces rimosus CN08 with Co(60)-γ rays. 125 OTC-producing colonies were obtained after screening on kanamycin containing medium. One mutant called Streptomyces rimosus γ-45 whose OTC production increased 19-fold (165 mg l(-1)) versus wild-type strain was selected. γ-45 mutant was used for OTC production under solid-state fermentation (SSF). Wheat bran (WB) was used as solid substrate and process parameters influencing OTC production were optimized. Solid-state fermentation increased the yield of antibiotic production (257 mg g(-1)) when compared with submerged fermentation. Ammonium sulphate as additional nitrogen source enhanced OTC level to 298 mg g(-1). Interestingly, OTC production by γ-45 mutant was insensitive to phosphate which opens the way to high OTC production even in medium containing phosphate necessary for optimal mycelia growth.
Collapse
|
14
|
Mahajan VK, Bari SB, Shirkhedkar AA, Surana SJ. Simultaneous densitometric TLC analysis of aceclofenac, paracetamol, and chlorzoxazone in tablets. ACTA CHROMATOGR 2008. [DOI: 10.1556/achrom.20.2008.4.8] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
15
|
Measuring Oxytetracycline Using a Simple Prepared DNA Immobilized on a Carbon Nanotube Paste Electrode in Fish Tissue. JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE 2007. [DOI: 10.5012/jkcs.2007.51.5.412] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
16
|
Kowalski C, Pomorska M, Sławik T. Development of HPLC with UV‐VIS Detection for the Determination of the Level of Oxytetracycline in the Biological Matrix. J LIQ CHROMATOGR R T 2006. [DOI: 10.1080/10826070600925030] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- C. Kowalski
- a Department of Pharmacology, Faculty of Veterinary Medicine , Agriculture University, Akademicka , Lublin, Poland
| | - M. Pomorska
- a Department of Pharmacology, Faculty of Veterinary Medicine , Agriculture University, Akademicka , Lublin, Poland
| | - T. Sławik
- b Department of Medicinal Chemistry, Faculty of Pharmacy , Medical University , Lublin, Poland
| |
Collapse
|
17
|
Sarafra-Yazdi A, Es’haghi Z. Antibiotic-assisted three-phase liquid-phase microextraction of aromatic amines from aqueous solutions combined with high-performance liquid chromatography. JOURNAL OF ANALYTICAL CHEMISTRY 2006. [DOI: 10.1134/s1061934806080120] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
18
|
|
19
|
Kurzawa M, Kowalczyk-Marzec A. Electrochemical determination of oxytetracycline in veterinary drugs. J Pharm Biomed Anal 2004; 34:95-102. [PMID: 14738923 DOI: 10.1016/j.japna.2003.08.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Conductometric, potentiometric and cyclic voltammetric (CV) titration methods are proposed for determination of oxytetracycline (OTC), commonly used in veterinary. The electrochemical titration of OTC hydrochloride with NH(4)Mo(7)O(24), NaVO(3), NaOH, AgNO(3) and FeCl(3) as titrants are reported. The proposed methods were found to be highly precise, having a relative standard deviation (R.S.D.) below 1.0%. Proposed electrochemical titrations were successfully applied to the assay of commercial preparations: Tetrox, Tetramutin OT and Neox, containing the above-mentioned antibiotics. The validity of the methods was tested by the recovery studies of standard addition to pharmaceuticals and results were found to be satisfactory.
Collapse
Affiliation(s)
- Marzanna Kurzawa
- Faculty of Chemistry, Nicolaus Copernicus University, 87-100, Toruń, ul. Gagarina 7, Poland.
| | | |
Collapse
|