1
|
Derayea SM, Abdulrazik SG, Attia TZ. Quantitative spectrofluorimetric method for determination of octreotide acetate synthetic peptide derivative in pure and its Sandostatin ampules forms. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2024; 305:123546. [PMID: 37864971 DOI: 10.1016/j.saa.2023.123546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Revised: 09/16/2023] [Accepted: 10/14/2023] [Indexed: 10/23/2023]
Abstract
A unique spectrofluorimetric protocol has been conceived for octreotide (a synthetic peptide drug) quantitation in both its authentic form and its application to dosage form. The protocol has been established simply upon condensation of octreotide by ninhydrin / phenyl acetaldehyde reagent in buffered media (pH 6.2). An intense fluorescence product has been formed and quantified at 463 nm (390 nm for excitation). After optimization for various experimental conditions, a wide linear interval (0.2-4.0 µg/ml) has been used to construct the calibration curve with a determination coefficient (r2) of 0.9994, a slope ± SD of 81.147 ± 0.7985, and a highly sensitive detection and quantitation limits nearly equal to 0.066 and 0.2 µg/ml, respectively. A proposed protocol has been checked in accordance with ICH validation guidelines, which indicate good accuracy and high precision of the proposed method. Furthermore, this protocol could be perfectly applied for the quantitative estimation of octreotide in its ampoules with a high degree of accuracy and precision. As a result, a developed protocol is ideally appropriate for fast and simple octreotide quantitative estimation in quality control laboratories.
Collapse
Affiliation(s)
- Sayed M Derayea
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt
| | - Shrouk G Abdulrazik
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt
| | - Tamer Z Attia
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt.
| |
Collapse
|
2
|
Ozkan E, Ozcelikay G, Gök Topak ED, Nemutlu E, Ozkan SA, Dizdar Ö, Aksoy S, Kır S. Molecularly imprinted electrochemical sensor for the selective and sensitive determination of octreotide in cancer patient plasma sample. Talanta 2023; 263:124679. [PMID: 37257237 DOI: 10.1016/j.talanta.2023.124679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 05/04/2023] [Accepted: 05/15/2023] [Indexed: 06/02/2023]
Abstract
In this study, a molecularly imprinted polymer film (P (ANI)@MIP) on the electrode surface was fabricated using aniline as a functional monomer and octreotide (OC) as a template molecule. The developed P (ANI)@MIP was electrochemically electropolymerized on a glassy carbon electrode (GCE) surface. Each step of MIP production was evaluated by viewing the [Fe (CN)6]3-/4- signal obtained using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The P (ANI)@MIP film layer was studied with a scanning electron microscope (SEM), Raman, and contact angle measurements. The parameters consisting of monomer, template ratio, cycle number, removal solution, removal time, and rebinding time were optimized to obtain the best electrochemical sensor. The developed method was validated in line with ICH guidelines. The linear range, LOD, and LOQ were found as 10-80 fM, 0.801 fM, and 2.670 fM, respectively. The selectivity of the method was tested with the response of somatostatin and lanreotide from the same growth hormone family by comparing the OC response. The developed P (ANI)@MIP/GCE sensor is the first reported method for electrochemical analysis of OC. The P (ANI)@MIP/GCE sensor exhibited high sensitivity and selectivity for OC. The novel MIP sensor was used to determine OC in cancer patient plasma samples. The concentration of OC in cancer patients varied between 8.98 ng/mL and 10.10 ng/mL.
Collapse
Affiliation(s)
- Ece Ozkan
- Ankara Medipol University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06790, Turkiye.
| | - Göksu Ozcelikay
- Ankara University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06560, Turkiye
| | - Elif Damla Gök Topak
- Hacettepe University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06100, Turkiye; Lokman Hekim University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06510, Turkiye
| | - Emirhan Nemutlu
- Hacettepe University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06100, Turkiye
| | - Sibel A Ozkan
- Ankara University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06560, Turkiye.
| | - Ömer Dizdar
- Hacettepe University, Cancer Institute, Medical Oncology Department, Ankara, 06100, Turkiye
| | - Sercan Aksoy
- Hacettepe University, Cancer Institute, Medical Oncology Department, Ankara, 06100, Turkiye
| | - Sedef Kır
- Hacettepe University, Faculty of Pharmacy, Analytical Chemistry Department, Ankara, 06100, Turkiye
| |
Collapse
|
3
|
Gadhave D, Khot S, Tupe S, Shinde M, Tagalpallewar A, Gorain B, Kokare C. Nose-to-brain delivery of octreotide acetate in situ gel for pituitary adenoma: Pharmacological and in vitro cytotoxicity studies. Int J Pharm 2022; 629:122372. [DOI: 10.1016/j.ijpharm.2022.122372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 10/31/2022] [Accepted: 11/02/2022] [Indexed: 11/07/2022]
|
4
|
Attia TZ, Abdulrazik SG, Dearyea SM. Facile spectrofluorimetric quantitation of octreotide, a synthetic peptide, in its pure form and pharmaceutical formulation; Evaluation of the method greenness. LUMINESCENCE 2022; 37:1914-1920. [PMID: 36044548 DOI: 10.1002/bio.4375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 08/02/2022] [Accepted: 08/28/2022] [Indexed: 11/10/2022]
Abstract
A new, rapid, highly sensitive, and affordable spectrofluorimetric approach has been constructed and validated for the determination of octreotide in its authentic form and pharmaceutical dosage form. Octreotide is an important synthetic analog of the naturally occurring somatostatin hormone. The developed spectrofluorimetric approach is actually dependent on the measurement of octreotide native fluorescence at emission wavelength of 342 nm after excitation at 218 nm. At optimal reaction circumstances, the calibration curve has been constructed over the concentration range of 200- 2000 ng ml-1 , with excellent linearity. The limits of detection and quantitation values were found to be 55 and 169 ng ml-1 , respectively. The developed approach has been effectively used to determine octreotide in its pharmaceutical ampoules, without interference from the excipients in the dosage form. The developed approach is simple, time-saving, and does not require multiple pretreatment steps for samples, costly apparatus, or dangerous materials. As a result, it can be actually used to detect and quantify octreotide acetate in quality control laboratories.
Collapse
Affiliation(s)
- Tamer Z Attia
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt
| | - Shrouk G Abdulrazik
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt
| | - Sayed M Dearyea
- Analytical Chemistry Department, Faculty of Pharmacy, Minia University, Minia, Egypt
| |
Collapse
|
5
|
Hydrophilic Interaction Liquid Chromatography Coupled with Fluorescence Detection (HILIC-FL) for the Quantitation of Octreotide in Injection Forms. ANALYTICA 2021. [DOI: 10.3390/analytica2040012] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Octreotide is a synthetic cyclic octapeptide analogue of somatostatin-14. It is mainly administered for the treatment of acromegaly, severe diarrhea, and neuroendocrine neoplasias. In this work, a hydrophilic interaction liquid chromatography (HILIC) method with fluorescence (FL) detection was developed and validated for the quantitation of octreotide in solutions for injection. Chromatographic separation was performed on an XBridge®-HILIC analytical column under isocratic elution with a short chromatographic run time of less than 10 min. The mobile phase consisted of ammonium bicarbonate 8.6 mM (pH 8.1)/acetonitrile 35/65 (v/v). The high sensitivity and selectivity of the fluorescence detection, with the excitation wavelength (λexcitation) set at 280 nm and the emission wavelength set at (λemission) 330 nm, enabled a simple sample preparation procedure that included only dilution steps. The calibration curve showed good linearity with a correlation coefficient greater than 0.998. The method was successfully applied to the analysis of commercially available octreotide injection forms.
Collapse
|
6
|
Al-Tannak NF, Cable CG, McArthur DA, Watson DG. A stability indicating assay for a combination of morphine sulphate with levomepromazine hydrochloride used in palliative care. J Clin Pharm Ther 2011; 37:71-3. [DOI: 10.1111/j.1365-2710.2011.01252.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
7
|
Bishara A, Domb AJ. PLA stereocomplexes for controlled release of somatostatin analogue. J Control Release 2005; 107:474-83. [PMID: 16140412 DOI: 10.1016/j.jconrel.2005.05.026] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2005] [Revised: 05/23/2005] [Accepted: 05/31/2005] [Indexed: 11/29/2022]
Abstract
Reversible stereoselective complexes were spontaneously formed from mixing acetonitrile solutions of enantiomeric D-poly(lactide) (D-PLA), L-poly(lactide) (L-PLA), and octreotide (an octapeptide, somatostatin analogue). Hetero-stereocomplexes of poly (D-lactide) and L-octreotide were obtained by spray freezing of solution of D-PLA and octreotide. An additional transition temperature close to the melting point of enantiomeric PLA was observed in DSC thermogram. The same phenomenon was observed in stereocomplex of D-PLA/L-PLA and octreotide. The enthalpy of both transition temperatures correlate with peptide content in the hetero-stereocomplex. The spray method produced compact and smooth micro particles compared to particles formed by precipitation in acetonitrile solution. The particle size of stereocomplexes was in the range of 1.5 to 4 microm for all formations. Increasing peptide concentration in the stereocomplex increases the release rate of the peptide, and increases polymer degradation rate as monitored by lactic acid release form stereocomplexes.
Collapse
Affiliation(s)
- Ashgan Bishara
- The Hebrew University of Jerusalem, 91120 Jerusalem, Israel
| | | |
Collapse
|
8
|
Fielding H, Kyaterekera N, Skellern GG, Tettey JN, McDade JR, Msuya Z, Watson DG, Urie J. The compatibility and stability of octreotide acetate in the presence of diamorphine hydrochloride in polypropylene syringes. Palliat Med 2000; 14:205-7. [PMID: 10858828 DOI: 10.1191/026921600666997498] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Varying concentrations of octreotide acetate (Sandostatin) and diamorphine hydrochloride were prepared and stored in polypropylene syringes at 37 degrees C in the dark. The solutions were analysed for octreotide acetate content using a validated HPLC method at regular intervals over a 48-h period. The results indicate that octreotide acetate remains stable in the presence of diamorphine hydrochloride at 37 degrees C for 24 h. In addition, the solutions prepared maintained their clarity, with no signs of precipitation upon visual examination under normal light conditions.
Collapse
|