1
|
Keller SP, Whitman GJR, Grant MC. Temporary Mechanical Circulatory Support after Cardiac Surgery. J Cardiothorac Vasc Anesth 2024; 38:2080-2088. [PMID: 38955616 DOI: 10.1053/j.jvca.2024.06.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2024] [Revised: 05/30/2024] [Accepted: 06/11/2024] [Indexed: 07/04/2024]
Abstract
Postcardiotomy shock in the cardiac surgical patient is a highly morbid condition characterized by profound myocardial impairment and decreased systemic perfusion inadequate to meet end-organ metabolic demand. Postcardiotomy shock is associated with significant morbidity and mortality. Poor outcomes motivate the increased use of mechanical circulatory support (MCS) to restore perfusion in an effort to prevent multiorgan injury and improve patient survival. Despite growing acceptance and adoption of MCS for postcardiotomy shock, criteria for initiation, clinical management, and future areas of clinical investigation remain a topic of ongoing debate. This article seeks to (1) define critical cardiac dysfunction in the patient after cardiotomy, (2) provide an overview of commonly used MCS devices, and (3) summarize the relevant clinical experience for various MCS devices available in the literature, with additional recognition for the role of MCS as a part of a modified approach to the cardiac arrest algorithm in the cardiac surgical patient.
Collapse
Affiliation(s)
- Steven P Keller
- Department of Medicine, Division of Pulmonary and Critical Care Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD
| | - Glenn J R Whitman
- Department of Surgery, Division of Cardiac Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD
| | - Michael C Grant
- Department of Surgery, Division of Cardiac Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD; Department of Anesthesiology and Critical Care Medicine, Divisions of Cardiac Anesthesia and Surgical Critical, The Johns Hopkins University School of Medicine, Baltimore, MD.
| |
Collapse
|
2
|
Bae DJ, Willey JZ, Ibeh C, Yuzefpolskaya M, Colombo PC. Stroke and Mechanical Circulatory Support in Adults. Curr Cardiol Rep 2023; 25:1665-1675. [PMID: 37921947 DOI: 10.1007/s11886-023-01985-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/19/2023] [Indexed: 11/05/2023]
Abstract
PURPOSE OF THE REVIEW Short-term and durable mechanical circulatory support (MCS) devices represent life-saving interventions for patients with cardiogenic shock and end-stage heart failure. This review will cover the epidemiology, risk factors, and treatment of stroke in this patient population. RECENT FINDINGS Short-term devices such as intra-aortic balloon pump, Impella, TandemHeart, and Venoatrial Extracorporal Membrane Oxygenation, as well as durable continuous-flow left ventricular assist devices (LVADs), improve cardiac output and blood flow to the vital organs. However, MCS use is associated with high rates of complications, including ischemic and hemorrhagic strokes which carry a high risk for death and disability. Improvements in MCS technology have reduced but not eliminated the risk of stroke. Mitigation strategies focus on careful management of anti-thrombotic therapies. While data on therapeutic options for stroke are limited, several case series reported favorable outcomes with thrombectomy for ischemic stroke patients with large vessel occlusions, as well as with reversal of anticoagulation for those with hemorrhagic stroke. Stroke in patients treated with MCS is associated with high morbidity and mortality. Preventive strategies are targeted based on the specific form of MCS. Improvements in the design of the newest generation device have reduced the risk of ischemic stroke, though hemorrhagic stroke remains a serious complication.
Collapse
Affiliation(s)
- David J Bae
- Division of Medicine, Center for Advanced Cardiac Care, Columbia University, New York, NY, USA
| | - Joshua Z Willey
- Division of Stroke and Cerebrovascular Disease, Department of Neurology, Columbia University Irving Medical Center, New York, NY, 10032, USA.
| | - Chinwe Ibeh
- Division of Stroke and Cerebrovascular Disease, Department of Neurology, Columbia University Irving Medical Center, New York, NY, 10032, USA
| | - Melana Yuzefpolskaya
- Division of Medicine, Center for Advanced Cardiac Care, Columbia University, New York, NY, USA
| | - Paolo C Colombo
- Division of Medicine, Center for Advanced Cardiac Care, Columbia University, New York, NY, USA
| |
Collapse
|
3
|
Schwarzman LS, Ishaaya EC, Patel D, Megowan N, Thomas JL. Characteristic adverse events with intra-aortic balloon pumps: An analysis of the U.S. Food and Drug Administration MAUDE database from 2016 to 2021. CARDIOVASCULAR REVASCULARIZATION MEDICINE 2023; 56:37-40. [PMID: 37302952 DOI: 10.1016/j.carrev.2023.05.432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Revised: 05/30/2023] [Accepted: 05/31/2023] [Indexed: 06/13/2023]
Abstract
INTRODUCTION The United States Food and Drug Administration Manufacturer and User Facility Device Experience (MAUDE) dataset represents a unique source for post-market surveillance data on adverse events (AE). An analysis of AE with percutaneous mechanical circulatory support (pMCS) devices has previously been reported specifically for microaxial flow pumps. The characteristic AE for the intra-aortic balloon pump (IABP) have not been similarly analyzed or reported. MATERIAL AND METHODS All events in the MAUDE dataset between January 1, 2016 and December 31, 2021 were reviewed involving the Linear, Mega and Sensation devices (Datascope/Getinge, Wayne New Jersey). Data was analyzed by two authors and categorized based on AE type, date, event type and device-related or patient-related AE. RESULTS A total of 2795 AE were reported over five years. Device malfunction (91.4 %) was the most frequent classification followed by death (5.6 %) and injury (3.0 %). Catheter deformation/fracture/leak accounted for 37.9 % of total AEs. The most common patient event categorization was asymptomatic (90.8 %). Vessel damage/hemorrhage occurred in 1.4 % of reports. Death occurred in 5.6 % of reports and was associated with cardiac arrest in 110 of 156 events. Thrombus formation was described in 1.1 % of AEs. Device optic AE were common and unique to Sensation catheters. Calibration errors were also more common with Sensation (4.6 % versus 1.3 %) compared to other models. CONCLUSIONS Publicly reported AE with IABPs are predominantly device malfunctions without clinical sequelae. Injury, vascular damage, bleeding and thrombosis AEs are not frequent amongst reported AEs. Emphasis should be placed on understanding mechanisms of device malfunction in order to improve both reliability and user experience.
Collapse
Affiliation(s)
| | - Ella C Ishaaya
- Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA, USA
| | - Dev Patel
- Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA, USA; Division of Cardiology, Harbor-UCLA Medical Center, Torrance, CA, USA
| | - Nichelle Megowan
- Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA, USA; Division of Cardiology, Harbor-UCLA Medical Center, Torrance, CA, USA
| | - Joseph L Thomas
- Department of Medicine, Harbor-UCLA Medical Center, Torrance, CA, USA; Division of Cardiology, Harbor-UCLA Medical Center, Torrance, CA, USA.
| |
Collapse
|
4
|
Hamdan R, Kadri Z, Abdallah H, Hamadeh A, Alsaedi E, Al Baba B, Shoka WA, Yassine N, Al Aila F, Gafar S, Mansour A, Lozon H, Daka LA, Soukieh F, Hamadi O, Jayyousi WA, Chah I, Balchi M, Abdallah Y, Nooryani AA. [Place du ballon de contre pulsion intra aortique dans l'infarctus aigu du myocarde compliqué par état de choc cardiogénique]. Ann Cardiol Angeiol (Paris) 2023; 72:101635. [PMID: 37639738 DOI: 10.1016/j.ancard.2023.101635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/01/2023] [Accepted: 08/05/2023] [Indexed: 08/31/2023]
Abstract
BACKGROUND AND METHODS Cardiogenic shock remains one of the leading causes of death in patients with myocardial infarction. The Intra-aortic balloon pump (IABP) has been widely used as a treatment for acute myocardial infarction (AMI), despite recommendations against its routine use. In this paper, our aim is to analyze and share our own experience with IABP in the setting of AMI. We retrospectively reviewed the files of patients admitted with AMI and cardiogenic shock and for whom IABP was inserted between June 2016 and December 2022. RESULTS 300 patients with AMI and cardiogenic shock were admitted and benefited from IABP insertion and primary coronary revascularization. The overall mortality rate was 62.3%, the site related complication rate was 0.6%, and the overall complications rate (including site related and major bleeding) was 10.6%. There was a significantly higher mortality in the group of patients where the Left Anterior Descending artery (LAD) was the culprit lesion, in the group of patients who required dialysis, the group who had creatinine levels greater than 200 um/L compared to the group who had creatinine lower than 200 um/L, and in patients older than 70 years. Interestingly, no difference in mortality was observed between men and women, single versus multiple vessel disease, and between STEMI and non-STEMI patients. CONCLUSION Mortality of AMI complicated by cardiogenic shock and treated by IABP remains high. However, IABP usage is associated with a low complication rate. Better selection criteria for IABP usage versus other more powerful mechanical circulatory support devices in such patients might improve the outcome for the patient.
Collapse
Affiliation(s)
- Righab Hamdan
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates.
| | - Zena Kadri
- Cardiology Department, Hotel Dieu de France, Beirut, Lebanon
| | | | - Ahmad Hamadeh
- University of Sharjah, Sharjah, United Arab Emirates
| | - Ehab Alsaedi
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Bassam Al Baba
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Wael Abo Shoka
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Noha Yassine
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Farah Al Aila
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Salma Gafar
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Anoop Mansour
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Hadeel Lozon
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Loai Abo Daka
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | - Farah Soukieh
- University of Sharjah, Sharjah, United Arab Emirates
| | - Omar Hamadi
- University of Sharjah, Sharjah, United Arab Emirates
| | | | - Islam Chah
- Cardiology department, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| | | | | | - Arif Al Nooryani
- Head of Cardiology Department, CEO, Al Qassimi Hospital, Emirates Health Services, Sharjah, United Arab Emirates
| |
Collapse
|
5
|
Mijares-Rojas IA, Trujillo LG, Lecompte-Osorio PA, Martinez Trevino EF, Munagala M. Aortic Dissection From an Intra-aortic Balloon Pump: A Dangerous Complication to Keep in Mind. Cureus 2023; 15:e39122. [PMID: 37332456 PMCID: PMC10273174 DOI: 10.7759/cureus.39122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/17/2023] [Indexed: 06/20/2023] Open
Abstract
Despite the benefits of the intra-aortic balloon pump (IABP) being a subject of debate, it remains a widely available and easy-to-use mechanical circulatory support device. Nonetheless, its use is not exempt from complications. Aortic dissection from IABP is an infrequent but deathly complication. We describe a case in which early recognition of the condition led to control through an endovascular approach. A 57-year-old male was admitted for acute decompensated heart failure requiring intravenous inotropic agents. While undergoing assessment for a heart transplant, he developed cardiogenic shock requiring initiation of mechanical circulatory support with an IABP. A few hours after device implantation, the patient developed acute tearing chest pain and was found to have an acute dissection in the descending thoracic aorta. Prompt liaison with the endovascular team led to a thoracic endovascular aortic repair to control the extent of the lesion.
Collapse
Affiliation(s)
- Ivan A Mijares-Rojas
- Internal Medicine, University of Miami Miller School of Medicine, Jackson Memorial Hospital, Miami, USA
| | - Luis G Trujillo
- Internal Medicine, University of Miami Miller School of Medicine, Jackson Memorial Hospital, Miami, USA
| | - Paola A Lecompte-Osorio
- Internal Medicine, University of Miami Miller School of Medicine, Jackson Memorial Hospital, Miami, USA
| | | | | |
Collapse
|
6
|
Gao Y, Li D, Dong H, Guo Y, Peng Y, Liu Y, Su P. Risk factors analysis of hyperbilirubinemia after off-pump coronary artery bypass grafting: a retrospective observational study. J Cardiothorac Surg 2021; 16:294. [PMID: 34629102 PMCID: PMC8503987 DOI: 10.1186/s13019-021-01678-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 09/25/2021] [Indexed: 12/04/2022] Open
Abstract
Background Hyperbilirubinemia is a common complication after off-pump coronary artery bypass grafting (OPCAB), but the incidence and the risk factors are unclear. This study aimed to analyze the incidence and risk factors of postoperative hyperbilirubinemia in patients undergoing OPCAB. Methods From December 2016 to March 2019, a total of 416 consecutive patients undergoing OPCAB were enrolled in this single-center retrospective study. Patients were divided into the normal serum total bilirubin group and the hyperbilirubinemia group based on the serum total bilirubin levels. Perioperative variables between the two groups were compared by univariate logistic regression analysis. Then, multivariate binary logistic regression analysis was used to analyze the independent risk factors of developing hyperbilirubinemia in patients underwent OPCAB. P < 0.05 was considered as statistically significant. Results Thirty two of 416 (7.7%) patients developed postoperative hyperbilirubinemia. Univariate regression analysis showed significant differences in gender (73.96% vs. 93.75%, P = 0.012), preoperative total bilirubin levels (11.92 ± 4.52 vs. 18.28 ± 7.57, P < 0.001), perioperative IABP implantation (22.66% vs. 43.75%, P = 0.008), perioperative blood transfusion (37.50% vs. 56.25%, P = 0.037) between the two groups. Multivariate logistic regression analysis revealed that elevated preoperative serum total bilirubin levels (OR = 1.225, 95% CI 1.145–1.310, P < 0.001), perioperative blood transfusion (OR = 4.488, 95% CI 1.876–10.737, P = 0.001) and perioperative IABP implantation (OR = 4.016, 95% CI 1.709–9.439, P = 0.001) were independent risk factors for hyperbilirubinemia after OPCAB. Conclusions Hyperbilirubinemia is also a common complication after OPCAB. Elevated preoperative serum total bilirubin levels, perioperative blood transfusion, and perioperative IABP implantation were independent risk factors for patients developing hyperbilirubinemia after OPCAB. Further studies need to be conducted to confirm the risk factors of hyperbilirubinemia after OPCAB procedure.
Collapse
Affiliation(s)
- Yingdi Gao
- Department of Cardiac Surgery, Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gong Ti South Road, Chaoyang District, Beijing, 100020, China
| | - Dongjie Li
- Department of Cardiac Surgery, Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gong Ti South Road, Chaoyang District, Beijing, 100020, China
| | - Honghong Dong
- Department of Thoracic Surgery, Beijing Chaoyang Hospital, Capital Medical University, Beijing, 100020, China
| | - Yulin Guo
- Department of Cardiac Surgery, Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gong Ti South Road, Chaoyang District, Beijing, 100020, China
| | - Yuanshu Peng
- Department of Cardiac Surgery, Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gong Ti South Road, Chaoyang District, Beijing, 100020, China
| | - Yan Liu
- Department of Cardiac Surgery, Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gong Ti South Road, Chaoyang District, Beijing, 100020, China
| | - Pixiong Su
- Department of Cardiac Surgery, Heart Center and Beijing Key Laboratory of Hypertension, Beijing Chaoyang Hospital, Capital Medical University, No. 8 Gong Ti South Road, Chaoyang District, Beijing, 100020, China.
| |
Collapse
|
7
|
Kelly J, Malloy R, Knowles D. Comparison of anticoagulated versus non-anticoagulated patients with intra-aortic balloon pumps. Thromb J 2021; 19:46. [PMID: 34187597 PMCID: PMC8243470 DOI: 10.1186/s12959-021-00295-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Accepted: 06/07/2021] [Indexed: 11/17/2022] Open
Abstract
Background There is limited guidance regarding the use of anticoagulation in patients on intra-aortic balloon pumps (IABP). The purpose of this study is to compare the safety outcomes in anticoagulated versus non-anticoagulated patients with an IABP. Methods This was a single center, retrospective chart review of patients admitted to the coronary care unit or cardiac surgery unit who received an IABP from May 2015 to July 2018. Patients who were anticoagulated with heparin while on an IABP were compared to those who were not anticoagulated. Major endpoints included a composite of thrombotic events and a composite of bleeding events. The major composite endpoint of thrombotic events included the incidence of ischemic stroke, any venous thromboembolism, device thrombosis, and limb ischemia. The major composite endpoint of bleeding events included major access site bleeding, minor access site bleeding, major non-access site bleeding, and minor non-access site bleeding. Minor endpoints included any major endpoint events occurring within 24 and 48 h of IABP insertion, hospital length of stay, intensive care unit length of stay, and in-hospital mortality. Results A total of 185 patients were evaluated for inclusion and 147 were included in the final analysis. There were 82 and 65 patients in the heparin and non-heparin groups, respectively. The composite endpoint of thrombotic events occurred in 7.3 and 7.7% in the heparin and non-heparin groups, respectively (p = 1). The composite bleeding endpoint occurred in 20.7 and 20.0% in the heparin and non-heparin groups, respectively (p = 0.91). There were no differences found in minor endpoints between groups. Conclusion There were no significant differences found in major endpoints of bleeding and thrombotic events in patients who received anticoagulation while on an IABP versus those who did not receive anticoagulation.
Collapse
Affiliation(s)
- Julie Kelly
- Department of Pharmacy Services, Brigham and Women's Hospital, 75 Francis St Boston, Boston, MA, 02215, USA.
| | - Rhynn Malloy
- Department of Pharmacy Services, Brigham and Women's Hospital, 75 Francis St Boston, Boston, MA, 02215, USA
| | - Danielle Knowles
- Department of Pharmacy Services, Brigham and Women's Hospital, 75 Francis St Boston, Boston, MA, 02215, USA
| |
Collapse
|
8
|
De Luca L, Uguccioni M, Putini RL, Natale E, Terranova A, Pugliese M, Biffani E, De Lio L, Piazza V, Musumeci F. Fondaparinux During Intra-Aortic Balloon Pump Counterpulsation in Acute Myocardial Infarction Patients Undergoing Percutaneous Coronary Intervention. Heart Lung Circ 2021; 30:1545-1551. [PMID: 33994282 DOI: 10.1016/j.hlc.2021.04.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 03/28/2021] [Accepted: 04/12/2021] [Indexed: 10/21/2022]
Abstract
BACKGROUND Although anticoagulation with unfractionated heparin (UFH) is commonly used during intra-aortic balloon pump (IABP) counterpulsation to prevent thromboembolic events, no data or guidelines exist to support this strategy, especially in the setting of acute myocardial infarction (AMI). This study sought to compare the short-term outcome of UFH vs fondaparinux in AMI patients who underwent successful percutaneous coronary intervention (PCI) and IABP insertion. METHODS The anticoagulation therapy of revascularised AMI patients who received IABP counterpulsation and admitted to a tertiary hospital in the last decade was retrospectively evaluated. The primary outcome was the occurrence of all-cause mortality, stroke or transient ischaemic attack, reinfarction, unplanned revascularisation, major or minor limb ischaemia, and any bleeding at 1 month. Propensity score matching was performed to compare the primary outcome between UFH and fondaparinux. RESULTS Of 1,355 AMI survivors at 2 days after hospital admission and who underwent successful PCI, an IABP was inserted in 197 (14.5%): 72 (36.5%) were treated with UFH and 125 (63.5%) with fondaparinux (2.5 mg o.d.). At clinical follow-up, completed in 98.5% of cases, the incidence of the primary outcome was 22.5% in UFH and 5.7% in fondaparinux groups (p=0.0009). More than two-thirds of the events included in the primary outcome were related to early bleeding complications. In the matched cohort of 62 patients, the primary outcome occurred in 14 (45.2%) patients in the UFH and two (6.5%) in the fondaparinux group (p=0.01). CONCLUSIONS This study suggested that fondaparinux is safer, by reducing early bleeding complications at one month, than UFH in the management of IABP.
Collapse
Affiliation(s)
- Leonardo De Luca
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy.
| | - Massimo Uguccioni
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy
| | - Rita Lucia Putini
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy
| | - Enrico Natale
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy
| | - Antonio Terranova
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy
| | - Marco Pugliese
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy
| | | | - Lucia De Lio
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy
| | - Vito Piazza
- Department of Cardiosciences, A. O. San Camillo-Forlanini, Roma, Italy
| | | |
Collapse
|
9
|
Three-Dimensional Computational Modeling of an Extra-Descending Aortic Assist Device Using Fluid-Structure Interaction. Ing Rech Biomed 2021. [DOI: 10.1016/j.irbm.2020.11.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
10
|
Kanyal R, Byrne J. The role of mechanical support devices during percutaneous coronary intervention. JRSM Cardiovasc Dis 2021; 10:20480040211014064. [PMID: 34691407 PMCID: PMC8532259 DOI: 10.1177/20480040211014064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 02/13/2021] [Accepted: 04/09/2021] [Indexed: 11/20/2022] Open
Abstract
The practice of interventional cardiology has changed dramatically over the last four decades since Andreas Gruentzig carried out the first balloon angioplasty. The obvious technological improvements in stent design and interventional techniques have facilitated the routine treatment of a higher risk cohort of patients, including those with complex coronary artery disease and poor left ventricular function, and more often in the setting of cardiogenic shock (CS) complicating acute myocardial infarction (AMI). The use of mechanical cardiac support (MCS) in these settings has been the subject of intense interest, particularly over the past decade . A number of commercially available devices now add to the interventional cardiologist's armamentarium when faced with the critically unwell or high-risk patient in the cardiac catheter laboratory. The theoretical advantage of such devices in these settings is clear- an increase in cardiac output and hence mean arterial pressure, with variable effects on coronary blood flow. In doing so, they have the potential to prevent the downward cascade of ischaemia and hypoperfusion, but there is a paucity of evidence to support their routine use in any patient subset, even those presenting with cardiogenic shock. This review will discuss the use and haemodynamic effect of MCS devices during percutaneous coronary intervention (PCI), and also examine the clinical evidence for their use in patients with cardiogenic shock, and those undergoing 'high risk' PCI.
Collapse
Affiliation(s)
- Ritesh Kanyal
- King’s College Hospital NHS Foundation Trust, London, UK
| | - Jonathan Byrne
- King’s College Hospital NHS Foundation Trust, London, UK
| |
Collapse
|
11
|
Davies RE, Rier JD, McCabe JM. Patient and Device Selection for Hemodynamic Support in High-Risk Percutaneous Coronary Intervention. Interv Cardiol Clin 2020; 10:121-130. [PMID: 33223101 DOI: 10.1016/j.iccl.2020.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
Coronary artery disease continues to advance resulting in the development of high-risk percutaneous interventions. This includes treatment of patients with multivessel disease, unprotected left main, acute myocardial infarction complicated by cardiogenic shock, and depressed left ventricular ejection fraction. As a result, mechanical circulatory support devices have evolved but require an understanding of patient hemodynamics, device mechanics, and access management. Trial data regarding device selection are limited by inclusion of cardiogenic shock patients, and observational studies are conflicted by selection bias, site familiarity with devices, and complication management; therefore, clinical judgment is required to treat high-risk patients appropriately.
Collapse
Affiliation(s)
- Rhian E Davies
- Department of Cardiology, University of Washington Medical Center, Seattle, WA, USA.
| | - Jeremy D Rier
- Department of Cardiology, University of Washington Medical Center, Seattle, WA, USA. https://twitter.com/jeremyrier
| | - James M McCabe
- Department of Cardiology, University of Washington Medical Center, 1959 Northeast Pacific Street Box 356422, Seattle, WA 98185, USA. https://twitter.com/J_M_McCabe
| |
Collapse
|
12
|
Kapur NK, Whitehead EH, Thayer KL, Pahuja M. The science of safety: complications associated with the use of mechanical circulatory support in cardiogenic shock and best practices to maximize safety. F1000Res 2020; 9. [PMID: 32765837 PMCID: PMC7391013 DOI: 10.12688/f1000research.25518.1] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 07/20/2020] [Indexed: 12/16/2022] Open
Abstract
Acute mechanical circulatory support (MCS) devices are widely used in cardiogenic shock (CS) despite a lack of high-quality clinical evidence to guide their use. Multiple devices exist across a spectrum from modest to complete support, and each is associated with unique risks. In this review, we summarize existing data on complications associated with the three most widely used acute MCS platforms: the intra-aortic balloon pump (IABP), Impella systems, and veno-arterial extracorporeal membrane oxygenation (VA-ECMO). We review evidence from available randomized trials and highlight challenges comparing complication rates from case series and comparative observational studies where a lack of granular data precludes appropriate matching of patients by CS severity. We further offer a series of best practices to help shock practitioners minimize the risk of MCS-associated complications and ensure the best possible outcomes for patients.
Collapse
Affiliation(s)
- Navin K Kapur
- The Cardiovascular Center for Research and Innovation, Tufts Medical Center, Boston, MA, USA
| | - Evan H Whitehead
- The Cardiovascular Center for Research and Innovation, Tufts Medical Center, Boston, MA, USA
| | - Katherine L Thayer
- The Cardiovascular Center for Research and Innovation, Tufts Medical Center, Boston, MA, USA
| | - Mohit Pahuja
- Division of Cardiology, Detroit Medical Center/Wayne State University School of Medicine, Detroit, MI, USA
| |
Collapse
|
13
|
Subramaniam AV, Barsness GW, Vallabhajosyula S, Vallabhajosyula S. Complications of Temporary Percutaneous Mechanical Circulatory Support for Cardiogenic Shock: An Appraisal of Contemporary Literature. Cardiol Ther 2019; 8:211-228. [PMID: 31646440 PMCID: PMC6828896 DOI: 10.1007/s40119-019-00152-8] [Citation(s) in RCA: 84] [Impact Index Per Article: 16.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Indexed: 12/11/2022] Open
Abstract
Cardiogenic shock (CS) is associated with hemodynamic compromise and end-organ hypoperfusion due to a primary cardiac etiology. In addition to vasoactive medications, percutaneous mechanical circulatory support (MCS) devices offer the ability to support the hemodynamics and prevent acute organ failure. Despite the wide array of available MCS devices for CS, there are limited data on the complications from these devices. In this review, we seek to summarize the complications of MCS devices in the contemporary era. Using a systems-based approach, this review covers domains of hematological, neurological, vascular, infectious, mechanical, and miscellaneous complications. These data are intended to provide a balanced narrative and aid in risk-benefit decision-making in this acutely ill population.
Collapse
Affiliation(s)
| | | | | | - Saraschandra Vallabhajosyula
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
- Division of Pulmonary and Critical Care Medicine, Department of Medicine, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
14
|
Jannati M, Attar A. Intra-aortic balloon pump postcardiac surgery: A literature review. JOURNAL OF RESEARCH IN MEDICAL SCIENCES 2019; 24:6. [PMID: 30815019 PMCID: PMC6383337 DOI: 10.4103/jrms.jrms_199_18] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Revised: 07/05/2018] [Accepted: 10/24/2018] [Indexed: 12/31/2022]
Abstract
Intra-aortic balloon pump (IABP) has been the most commonly used mechanical assist circulatory device in many postcardiotomy low output disorders for decades. Mechanism of IABP is based on its inflation in time of the diastolic pressure in the aortic root resulting increase in the blood and oxygen amount of the coronary artery and its deflation in left ventricular afterload during the systolic period. Prophylactic and postoperative application of IABP has been suggested by researchers, which has been commonly used in high-risk patients undertaking coronary artery bypass grafting surgery or percutaneous coronary intervention. Other researchers put forward the idea of the percutaneous IABP insertion throughout the left axillary artery as a reliable and relatively well-tolerated approach and also as a recovery tool to bridge patients with end-stage heart failure to heart transplantation. The current review was aimed to give further insight into routine IABP application by presenting the basic principles and trends in the incidence, management, role of IABP recovery, and long-lasting mortality outcomes in patients with cardiovascular disorders and discussing previous and current evidence.
Collapse
Affiliation(s)
- Mansour Jannati
- Department of Cardiovascular Surgery, Faghihi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
| | - Armin Attar
- Cardiovascular Research Center, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
15
|
Keeble TR, Karamasis GV, Rothman MT, Ricksten SE, Ferrari M, Hullin R, Scherstén F, Reitan O, Kirking ST, Cleland JG, Smith EJ. Percutaneous haemodynamic and renal support in patients presenting with decompensated heart failure: A multi-centre efficacy study using the Reitan Catheter Pump (RCP). Int J Cardiol 2019; 275:53-58. [DOI: 10.1016/j.ijcard.2018.09.085] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/03/2018] [Revised: 09/07/2018] [Accepted: 09/24/2018] [Indexed: 01/11/2023]
|
16
|
|
17
|
Abstract
Over half of the nearly two million healthcare-associated infections can be attributed to indwelling medical devices. In this review, we highlight the difficulty in diagnosing implantable device-related infection and how this leads to a likely underestimate of the prevalence. We then provide a length-scale conceptualization of device-related infection pathogenesis. Within this conceptualization we focus specifically on biofilm formation and the role of host immune and coagulation systems. Using this framework, we describe how current and developing preventative strategies target specific processes along the entire length-scale. In light of the significant time horizon for the development and translation of new preventative technologies, we also emphasize the need for parallel development of in situ treatment strategies. Specific examples of both preventative and treatment strategies and how they align with the length-scale conceptualization are described.
Collapse
|
18
|
Abstract
INTRODUCTION Robots have been employed in cardiovascular therapy as surgical tools and for automation of hospital systems. Soft robots are a new kind of robot made of soft deformable materials, that are uniquely suited for biomedical applications because they are inherently less likely to injure body tissues and more likely to adapt to biological environments. Awareness of the soft robotic systems under development will help promote clinician involvement in their successful clinical translation. Areas covered: The most advanced soft robotic systems, across the size scale from nano to macro, that have shown the most promise for clinical application in cardiovascular therapy because they offer solutions where a clear therapeutic need still exists. We discuss nano and micro scale technology that could help improve targeted therapy for cardiac regeneration in ischemic heart disease, and soft robots for mechanical circulatory support. Additionally, we suggest where the gaps in the technology currently lie. Expert commentary: Soft robotic technology has now matured from the proof-of-concept phase to successful animal testing. With further refinement in materials and clinician guided application, they will be a useful complement for cardiovascular therapy.
Collapse
Affiliation(s)
- Isaac Wamala
- a Klinik für Herz- , Thorax- und Gefäßchirurgie, Deutsches Herzzentrum Berlin , Berlin , Germany
| | - Ellen T Roche
- b Discipline of Biomedical Engineering , College of Engineering and Informatics, National University of Ireland , Galway , Ireland
| | - Frank A Pigula
- c Rudd Heart and Lung Center , University of Louisville - Jewish Hospital , Louisville , USA
| |
Collapse
|
19
|
Esposito M, Bader Y, Pedicini R, Breton C, Mullin A, Kapur NK. The role of acute circulatory support in ST-segment elevation myocardial infarction complicated by cardiogenic shock. Indian Heart J 2017; 69:668-674. [PMID: 29054200 PMCID: PMC5650570 DOI: 10.1016/j.ihj.2017.05.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2017] [Revised: 05/05/2017] [Accepted: 05/12/2017] [Indexed: 01/05/2023] Open
Abstract
In the setting of ST-segment elevation myocardial infarction (STEMI) complicated by cardiogenic shock, three primary treatment objectives include providing circulatory support, ventricular unloading, and restoring myocardial perfusion. In addition to primary percutaneous coronary intervention, each of these three objectives can be achieved with appropriate use of an acute mechanical circulatory support (AMCS) pump. Over the past decade, utilization of percutaneously-delivered AMCS devices including the Impella axial-flow catheter, TandemHeart left atrial-to-femoral artery bypass system, and veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has grown exponentially. In this review, we will discuss the hemodynamic impact of each AMCS device and clinical data surrounding their use in the setting of STEMI complicated by cardiogenic shock.
Collapse
Affiliation(s)
- Michele Esposito
- The Cardiovascular Center, Tufts Medical Center, Boston, MA, United States
| | - Yousef Bader
- The Cardiovascular Center, Tufts Medical Center, Boston, MA, United States
| | - Robert Pedicini
- The Cardiovascular Center, Tufts Medical Center, Boston, MA, United States
| | - Catalina Breton
- The Cardiovascular Center, Tufts Medical Center, Boston, MA, United States
| | - Andrew Mullin
- The Cardiovascular Center, Tufts Medical Center, Boston, MA, United States
| | - Navin K Kapur
- The Cardiovascular Center, Tufts Medical Center, Boston, MA, United States.
| |
Collapse
|
20
|
Horvath MA, Wamala I, Rytkin E, Doyle E, Payne CJ, Thalhofer T, Berra I, Solovyeva A, Saeed M, Hendren S, Roche ET, Del Nido PJ, Walsh CJ, Vasilyev NV. An Intracardiac Soft Robotic Device for Augmentation of Blood Ejection from the Failing Right Ventricle. Ann Biomed Eng 2017; 45:2222-2233. [PMID: 28512702 DOI: 10.1007/s10439-017-1855-z] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2017] [Accepted: 05/11/2017] [Indexed: 01/04/2023]
Abstract
We introduce an implantable intracardiac soft robotic right ventricular ejection device (RVED) for dynamic approximation of the right ventricular (RV) free wall and the interventricular septum (IVS) in synchrony with the cardiac cycle to augment blood ejection in right heart failure (RHF). The RVED is designed for safe and effective intracardiac operation and consists of an anchoring system deployed across the IVS, an RV free wall anchor, and a pneumatic artificial muscle linear actuator that spans the RV chamber between the two anchors. Using a ventricular simulator and a custom controller, we characterized ventricular volume ejection, linear approximation against different loads and the effect of varying device actuation periods on volume ejection. The RVED was then tested in vivo in adult pigs (n = 5). First, we successfully deployed the device into the beating heart under 3D echocardiography guidance (n = 4). Next, we performed a feasibility study to evaluate the device's ability to augment RV ejection in an experimental model of RHF (n = 1). RVED actuation augmented RV ejection during RHF; while further chronic animal studies will provide details about the efficacy of this support device. These results demonstrate successful design and implementation of the RVED and its deployment into the beating heart. This soft robotic ejection device has potential to serve as a rapidly deployable system for mechanical circulatory assistance in RHF.
Collapse
Affiliation(s)
- Markus A Horvath
- Wyss Institute for Biologically Inspired Engineering at Harvard University, Boston, MA, USA.,Boston Children's Hospital, Harvard Medical School, Boston, MA, USA.,Harvard John A. Paulson School of Engineering and Applied Sciences, Cambridge, MA, USA
| | - Isaac Wamala
- Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Eric Rytkin
- Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | | | - Christopher J Payne
- Wyss Institute for Biologically Inspired Engineering at Harvard University, Boston, MA, USA.,Harvard John A. Paulson School of Engineering and Applied Sciences, Cambridge, MA, USA
| | - Thomas Thalhofer
- Wyss Institute for Biologically Inspired Engineering at Harvard University, Boston, MA, USA
| | - Ignacio Berra
- Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Anna Solovyeva
- Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Mossab Saeed
- Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | | | - Ellen T Roche
- Wyss Institute for Biologically Inspired Engineering at Harvard University, Boston, MA, USA.,Harvard John A. Paulson School of Engineering and Applied Sciences, Cambridge, MA, USA
| | - Pedro J Del Nido
- Boston Children's Hospital, Harvard Medical School, Boston, MA, USA
| | - Conor J Walsh
- Wyss Institute for Biologically Inspired Engineering at Harvard University, Boston, MA, USA.,Harvard John A. Paulson School of Engineering and Applied Sciences, Cambridge, MA, USA
| | | |
Collapse
|
21
|
Sola M, Venkatesh K, Caughey M, Rayson R, Dai X, Stouffer GA, Yeung M. Ratio of systolic blood pressure to left ventricular end-diastolic pressure at the time of primary percutaneous coronary intervention predicts in-hospital mortality in patients with ST-elevation myocardial infarction. Catheter Cardiovasc Interv 2017; 90:389-395. [DOI: 10.1002/ccd.26963] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2016] [Revised: 01/09/2017] [Accepted: 01/16/2017] [Indexed: 12/22/2022]
Affiliation(s)
- Michael Sola
- University of North Carolina School of Medicine, University of North Carolina; Chapel Hill NC
| | - Kiran Venkatesh
- Department of Medicine; Division of Cardiology, University of Massachusetts Medical School; Worcester MA
| | - Melissa Caughey
- Department of Medicine; Division of Cardiology and McAllister Heart Institute, University of North Carolina; Chapel Hill NC
| | - Robert Rayson
- Department of Medicine; Division of Cardiology and McAllister Heart Institute, University of North Carolina; Chapel Hill NC
| | - Xuming Dai
- Department of Medicine; Division of Cardiology and McAllister Heart Institute, University of North Carolina; Chapel Hill NC
| | - George A. Stouffer
- Department of Medicine; Division of Cardiology and McAllister Heart Institute, University of North Carolina; Chapel Hill NC
| | - Michael Yeung
- Department of Medicine; Division of Cardiology and McAllister Heart Institute, University of North Carolina; Chapel Hill NC
| |
Collapse
|
22
|
MacKay EJ, Patel PA, Gutsche JT, Weiss SJ, Augoustides JG. Contemporary Clinical Niche for Intra-Aortic Balloon Counterpulsation in Perioperative Cardiovascular Practice: An Evidence-Based Review for the Cardiovascular Anesthesiologist. J Cardiothorac Vasc Anesth 2017; 31:309-320. [DOI: 10.1053/j.jvca.2016.07.036] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Indexed: 01/10/2023]
|
23
|
Harris M, Karamasis GV, Chotai S, Tang KH, Clesham GJ, Kelly PA. Spinal cord infarction post cardiac arrest in STEMI: A potential complication of intra-aortic balloon pump use. ACTA ACUST UNITED AC 2016; 18:18-21. [PMID: 27736197 DOI: 10.1080/17482941.2016.1232411] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Intra-aortic balloon pump (IABP) is commonly used as a cardiac assist device in various clinical situations: cardiogenic shock, mechanical complications of acute myocardial infarction, high risk percutaneous coronary interventions, coronary artery bypass graft surgery and refractory unstable angina and ventricular arrhythmias as bridge to therapy. Although current data support its safety, there is limited or no support for its efficacy. We present the case of spinal cord infarction after IABP use in a patient who presented with ST elevation myocardial infarction and cardiac arrest and we discuss the potential mechanism of such a devastating complication.
Collapse
Affiliation(s)
- Matthew Harris
- a Department of Cardiology , The Essex Cardiothoracic Centre , Nethermayne, Essex , UK
| | - Grigoris V Karamasis
- a Department of Cardiology , The Essex Cardiothoracic Centre , Nethermayne, Essex , UK
| | - Shayna Chotai
- a Department of Cardiology , The Essex Cardiothoracic Centre , Nethermayne, Essex , UK
| | - Kare H Tang
- a Department of Cardiology , The Essex Cardiothoracic Centre , Nethermayne, Essex , UK
| | - Gerald J Clesham
- a Department of Cardiology , The Essex Cardiothoracic Centre , Nethermayne, Essex , UK
| | - Paul A Kelly
- a Department of Cardiology , The Essex Cardiothoracic Centre , Nethermayne, Essex , UK
| |
Collapse
|
24
|
Briceno N, Kapur NK, Perera D. Percutaneous mechanical circulatory support: current concepts and future directions. Heart 2016; 102:1494-507. [DOI: 10.1136/heartjnl-2015-308562] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
|
25
|
Parissis H, Graham V, Lampridis S, Lau M, Hooks G, Mhandu PC. IABP: history-evolution-pathophysiology-indications: what we need to know. J Cardiothorac Surg 2016; 11:122. [PMID: 27487772 PMCID: PMC4972967 DOI: 10.1186/s13019-016-0513-0] [Citation(s) in RCA: 98] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2015] [Accepted: 07/27/2016] [Indexed: 11/18/2022] Open
Abstract
Treatment with the intraaortic balloon pump (IABP) is the most common form of mechanical support for the failing heart. Augmentation of diastolic pressure during balloon inflation contributes to the coronary circulation and the presystolic deflation of the balloon reduces the resistance to systolic output. Consequently, the myocardial work is reduced. The overall effect of the IABP therapy is an increase in the myocardial oxygen supply/demand ratio and thus in endocardial viability. This is an overall synopsis of what we need to know regarding IABP. Furthermore, this review article attempts to systematically delineate the pathophysiology linked with the hemodynamic consequences of IABP therapy. The authors also look at the future of the use of the balloon pump and conclude that the positive multi-systemic hemodynamic regulation during IABP treatment should further justify its use.
Collapse
Affiliation(s)
- H Parissis
- Cardiothoracics Department, Royal Victoria Hospital, Belfast, Northern Ireland
| | - V Graham
- Cardiothoracics Department, Royal Victoria Hospital, Belfast, Northern Ireland.
| | - S Lampridis
- Cardiothoracics Department, Royal Victoria Hospital, Belfast, Northern Ireland
| | - M Lau
- Cardiothoracics Department, Royal Victoria Hospital, Belfast, Northern Ireland
| | - G Hooks
- Cardiothoracics Department, Royal Victoria Hospital, Belfast, Northern Ireland
| | - P C Mhandu
- Cardiothoracics Department, Royal Victoria Hospital, Belfast, Northern Ireland
| |
Collapse
|
26
|
Konishi T, Funayama N, Yamamoto T, Nishihara H, Hotta D, Kikuchi K, Yokoyama H, Ohori K. Intraprocedural left ventricular free wall rupture diagnosed by left ventriculogram in a patient with infero-posterior myocardial infarction and severe aortic stenosis. BMC Cardiovasc Disord 2016; 16:126. [PMID: 27266264 PMCID: PMC4895822 DOI: 10.1186/s12872-016-0302-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2015] [Accepted: 05/30/2016] [Indexed: 05/29/2023] Open
Abstract
Background Left ventricular wall rupture remains a major lethal complication of acute myocardial infarction and hypertension is a well-known predisposing factor of cardiac rupture after myocardial infarction. Case presentation An 87-year-old man was admitted to our hospital, diagnosed as acute myocardial infarction (AMI). The echocardiogram showed 0.67-cm2 aortic valve, consistent with severe aortic stenosis (AS). A coronary angiography showed a chronic occlusion of the proximal left circumflex artery and a 99 % stenosis and thrombus in the mid right coronary artery. During percutaneous angioplasty of the latter, transient hypotension and bradycardia developed at the time of balloon inflation, and low doses of noradrenaline and etilefrine were intravenously administered as needed. The patient suddenly lost consciousness and developed electro-mechanical dissociation. Cardio-pulmonary resuscitation followed by insertion of an intra-aortic balloon pump (IABP) and percutaneous cardiopulmonary support were initiated. The echocardiogram revealed moderate pericardial effusion, though the site of free wall rupture was not distinctly visible. A left ventriculogram clearly showed an infero-posterior apical wall rupture. Surgical treatment was withheld because of the interim development of brain death. Conclusions In this patient, who presented with severe AS, the administration of catecholamine to stabilize the blood pressure probably increased the intraventricular pressures considerably despite apparently normal measurements of the central aortic pressure. IABP, temporary pacemaker, or both are recommended instead of intravenous catecholamines for patients with AMI complicated with significant AS to stabilize hemodynamic function during angioplasty. Electronic supplementary material The online version of this article (doi:10.1186/s12872-016-0302-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Takao Konishi
- Department of Cardiology, Hokkaido Cardiovascular Hospital, 1-30, West 13, South 27, Chuou-ku, Sapporo, 064-8622, Japan. .,Department of Translational Pathology, Hokkaido University School of Medicine, Sapporo, Japan.
| | - Naohiro Funayama
- Department of Cardiology, Hokkaido Cardiovascular Hospital, 1-30, West 13, South 27, Chuou-ku, Sapporo, 064-8622, Japan
| | - Tadashi Yamamoto
- Department of Cardiology, Hokkaido Cardiovascular Hospital, 1-30, West 13, South 27, Chuou-ku, Sapporo, 064-8622, Japan
| | - Hiroshi Nishihara
- Department of Translational Pathology, Hokkaido University School of Medicine, Sapporo, Japan
| | - Daisuke Hotta
- Department of Cardiology, Hokkaido Cardiovascular Hospital, 1-30, West 13, South 27, Chuou-ku, Sapporo, 064-8622, Japan
| | - Kenjiro Kikuchi
- Department of Cardiology, Hokkaido Cardiovascular Hospital, 1-30, West 13, South 27, Chuou-ku, Sapporo, 064-8622, Japan
| | - Hideo Yokoyama
- Department of Cardiovascular Surgery, Hokkaido Cardiovascular Hospital, Sapporo, Japan
| | - Katsumi Ohori
- Department of Cardiovascular Surgery, Hokkaido Cardiovascular Hospital, Sapporo, Japan
| |
Collapse
|
27
|
Clinical characteristics and outcomes after unplanned intraaortic balloon counterpulsation in the Counterpulsation to Reduce Infarct Size Pre-PCI Acute Myocardial Infarction trial. Am Heart J 2016; 174:7-13. [PMID: 26995364 DOI: 10.1016/j.ahj.2015.12.004] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Accepted: 12/03/2015] [Indexed: 12/25/2022]
Abstract
BACKGROUND Despite advances in primary percutaneous coronary intervention (pPCI) and regional systems of care, the development of cardiogenic shock is associated with poor clinical outcomes in patients with ST-segment elevation myocardial infarction (STEMI). We sought to better characterize the baseline characteristics and clinical outcomes of patients who underwent crossover to intraaortic balloon counterpulsation (IABC) in the CRISP AMI trial. METHODS Patients with anterior STEMI were randomized to IABC before pPCI or pPCI alone. Infarct size and 6-month clinical outcomes were evaluated in patients both in the pPCI-alone group who did undergo crossover to IABC and those who did not undergo crossover to IABC. RESULTS Among 176 patients randomized to pPCI alone, 161 patients did not later receive IABC during the index hospitalization, and 15 patients (8.5%) underwent crossover and did receive unplanned IABC. Hypotension and/or cardiogenic shock precipitated crossover to IABC in 12 patients (80%). Patients who underwent crossover to IABC demonstrated lower systolic and diastolic blood pressures on admission. At 6 months, rates of death (26.7% vs 3.1%, P = .003), readmission for severe hypotension (53.3% vs 3.7%, P < .001), resuscitated cardiac arrest, and ventricular arrhythmia were higher in the group that did crossover to IABC. Crossover to IABC was not associated with increased infarct size. CONCLUSIONS The most significant predictor of crossover to IABC in the setting of anterior STEMI was relative hypotension at the time of hospital admission, and crossover to IABC in CRISP AMI was associated with significantly worse clinical outcomes.
Collapse
|
28
|
Bezerra CG, Adam EL, Baptista ML, Ciambelli GS, Kopel L, Bernoche C, Lopes LNGD, Macatrão-Costa MF, Falcão BDAA, Lage SG. Aortic Counterpulsation Therapy in Patients with Advanced Heart Failure: Analysis of the TBRIDGE Registry. Arq Bras Cardiol 2015; 106:26-32. [PMID: 26690691 PMCID: PMC4728592 DOI: 10.5935/abc.20150147] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2015] [Accepted: 10/14/2015] [Indexed: 11/24/2022] Open
Abstract
Background The use of aortic counterpulsation therapy in advanced heart failure is
controversial. Objectives To evaluate the hemodynamic and metabolic effects of intra-aortic
balloon pump (IABP) and its impact on 30-day mortality in patients
with heart failure. Methods Historical prospective, unicentric study to evaluate all patients
treated with IABP betwen August/2008 and July/2013, included in an
institutional registry named TBRIDGE (The Brazilian Registry of
Intra-aortic balloon pump in Decompensated heart failure - Global
Evaluation). We analyzed changes in oxygen central venous saturation
(ScvO2), arterial lactate, and use of vasoactive drugs
at 48 hours after IABP insertion. The 30-day mortality was estimated
by the Kaplan-Meier method and diferences in subgroups were evaluated
by the Log-rank test. Results A total of 223 patients (mean age 49 ± 14 years) were included.
Mean left ventricle ejection fraction was 24 ± 10%, and 30% of
patients had Chagas disease. Compared with pre-IABP insertion, we
observed an increase in ScvO2 (50.5% vs. 65.5%, p <
0.001) and use of nitroprusside (33.6% vs. 47.5%, p < 0.001), and a
decrease in lactate levels (31.4 vs. 16.7 mg/dL, p < 0.001) and use
of vasopressors (36.3% vs. 25.6%, p = 0.003) after IABP insertion.
Thirty-day survival was 69%, with lower mortality in Chagas disease
patients compared without the disease (p = 0.008). Conclusion After 48 hours of use, IABP promoted changes in the use of vasoactive
drugs, improved tissue perfusion. Chagas etiology was associated with
lower 30-day mortality. Aortic counterpulsation therapy is an
effective method of circulatory support for patients waiting for heart
transplantation.
Collapse
Affiliation(s)
| | - Eduardo Leal Adam
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Mariana Lins Baptista
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | | | - Liliane Kopel
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | - Claudia Bernoche
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| | | | | | | | - Silvia Gelas Lage
- Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, São Paulo, SP, Brazil
| |
Collapse
|
29
|
Vondran M, Rastan AJ, Tillmann E, Seeburger J, Schröter T, Dhein S, Bakhtiary F, Mohr FW. Intra-Aortic Balloon Pump Malposition Reduces Visceral Artery Perfusion in an Acute Animal Model. Artif Organs 2015; 40:334-40. [PMID: 26366459 DOI: 10.1111/aor.12563] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Visceral artery perfusion can be potentially affected by intra-aortic balloon pump (IABP) catheters. We utilized an animal model to quantify the acute impact of a low balloon position on mesenteric artery perfusion. In six pigs (78 ± 7 kg), a 30-cc IABP was placed in the descending aorta in a transfemoral procedure. The celiac artery (CA) and the cranial mesenteric artery (CMA) were surgically dissected. Transit time blood flow was measured for (i) baseline, (ii) 1:1 augmentation with the balloon proximal to the visceral arteries, and (iii) 1:1 augmentation with the balloon covering the visceral arteries. Blood flow in the CMA and CA was reduced by 17 and 24%, respectively, when the balloon compromised visceral arteries compared with a position above the visceral arteries (flow in mL/min: CMA: (i) 1281 ± 512, (ii) 1389 ± 287, (iii) 1064 ± 276, P < 0.05 for 3 vs. 1 and 3 vs. 2; CA: (i) 885 ± 370, (ii) 819 ± 297, (iii) 673 ± 315; P < 0.05 for 3 vs. 1). The covering of visceral arteries by an IABP balloon causes a significant reduction of visceral artery perfusion; thus, the positioning of this device during implantation is critical for obtaining a satisfactory outcome.
Collapse
Affiliation(s)
- Maximilian Vondran
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - Ardawan J Rastan
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - Eugen Tillmann
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - Jörg Seeburger
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - Thomas Schröter
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - Stefan Dhein
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - Farhad Bakhtiary
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| | - Friedrich-Wilhelm Mohr
- Department of Cardiac Surgery, Heart Center Leipzig, University of Leipzig, Leipzig, Germany
| |
Collapse
|
30
|
Schmidt M, Burrell A, Roberts L, Bailey M, Sheldrake J, Rycus PT, Hodgson C, Scheinkestel C, Cooper DJ, Thiagarajan RR, Brodie D, Pellegrino V, Pilcher D. Predicting survival after ECMO for refractory cardiogenic shock: the survival after veno-arterial-ECMO (SAVE)-score. Eur Heart J 2015; 36:2246-56. [DOI: 10.1093/eurheartj/ehv194] [Citation(s) in RCA: 485] [Impact Index Per Article: 53.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2014] [Accepted: 04/29/2015] [Indexed: 11/14/2022] Open
|
31
|
Gilani FS, Farooqui S, Doddamani R, Gruberg L. Percutaneous Mechanical Support in Cardiogenic Shock: A Review. CLINICAL MEDICINE INSIGHTS-CARDIOLOGY 2015; 9:23-8. [PMID: 26052235 PMCID: PMC4448941 DOI: 10.4137/cmc.s19707] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2014] [Revised: 04/09/2015] [Accepted: 04/28/2015] [Indexed: 01/06/2023]
Abstract
Cardiogenic shock (CS) is a life-threatening condition associated with significant morbidity and mortality. Pharmacological therapy is often the first line of treatment but mechanical support can provide substantial hemodynamic improvement in refractory CS. Percutaneous mechanical support devices are placed in a minimally invasive manner and provide life-saving assistance to the failing myocardium. We review the percutaneous devices currently available, the evidence behind their use, and the new advances in percutaneous technology being evaluated for the treatment of CS.
Collapse
Affiliation(s)
- Fahad Syed Gilani
- Division of Cardiovascular Medicine, Boston University School of Medicine, Boston Medical Center. Boston, MA, USA
| | - Sarah Farooqui
- Division of Cardiovascular Medicine, Boston University School of Medicine, Boston Medical Center. Boston, MA, USA
| | - Rajiv Doddamani
- Division of Cardiovascular Medicine, Boston University School of Medicine, Boston Medical Center. Boston, MA, USA
| | - Luis Gruberg
- Division of Cardiovascular Disease, Department of Internal Medicine, Stony Brook University Medical Center, Stony Brook, NY, USA
| |
Collapse
|
32
|
Kapur NK, Esposito M. Hemodynamic Support with Percutaneous Devices in Patients with Heart Failure. Heart Fail Clin 2015; 11:215-30. [DOI: 10.1016/j.hfc.2014.12.012] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
33
|
Unverzagt S, Buerke M, de Waha A, Haerting J, Pietzner D, Seyfarth M, Thiele H, Werdan K, Zeymer U, Prondzinsky R. Intra-aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock. Cochrane Database Syst Rev 2015; 2021:CD007398. [PMID: 25812932 PMCID: PMC8454261 DOI: 10.1002/14651858.cd007398.pub3] [Citation(s) in RCA: 60] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
BACKGROUND Intra-aortic balloon pump counterpulsation (IABP) is currently the most commonly used mechanical assist device for patients with cardiogenic shock due to acute myocardial infarction. Although there has been only limited evidence from randomised controlled trials, the previous guidelines of the American Heart Association/American College of Cardiology (AHA/ACC) and the European Society of Cardiology (ESC) strongly recommended the use of the IABP in patients with infarction-related cardiogenic shock on the basis of pathophysiological considerations, non-randomised trials and registry data. The recent guidelines downgraded the recommendation based on a meta-analysis which could only include non-randomised trials showing conflicting results. Up to now, there have been no guideline recommendations and no actual meta-analysis including the results of the large randomised multicentre IABP-SHOCK II Trial which showed no survival benefit with IABP support. This systematic review is an update of the review published in 2011. OBJECTIVES To evaluate, in terms of efficacy and safety, the effect of IABP versus non-IABP or other assist devices guideline compliant standard therapy on mortality and morbidity in patients with acute myocardial infarction complicated by cardiogenic shock. SEARCH METHODS Searches of CENTRAL, MEDLINE (Ovid) and EMBASE (Ovid), LILACS, IndMed and KoreaMed, registers of ongoing trials and proceedings of conferences were updated in October 2013. Reference lists were scanned and experts in the field contacted to obtain further information. No language restrictions were applied. SELECTION CRITERIA Randomised controlled trials on patients with acute myocardial infarction complicated by cardiogenic shock. DATA COLLECTION AND ANALYSIS Data collection and analysis were performed according to the published protocol. Individual patient data were provided for six trials and merged with aggregate data. Summary statistics for the primary endpoints were hazard ratios (HRs) and odds ratios (ORs) with 95% confidence intervals (CIs). MAIN RESULTS Seven eligible studies were identified from a total of 2314 references. One new study with 600 patients was added to the original review. Four trials compared IABP to standard treatment and three to other percutaneous left assist devices (LVAD). Data from a total of 790 patients with acute myocardial infarction and cardiogenic shock were included in the updated meta-analysis: 406 patients were treated with IABP and 384 patients served as controls; 339 patients were treated without assisting devices and 45 patients with other LVAD. The HR for all-cause 30-day mortality of 0.95 (95% CI 0.76 to 1.19) provided no evidence for a survival benefit. Different non-fatal cardiovascular events were reported in five trials. During hospitalisation, 11 and 4 out of 364 patients from the intervention groups suffered from reinfarction or stroke, respectively. Altogether 5 out of 363 patients from the control group suffered from reinfarction or stroke. Reocclusion was treated with subsequent re-revascularization in 6 out of 352 patients from the intervention group and 13 out of 353 patients of the control group. The high incidence of complications such as moderate and severe bleeding or infection in the control groups has to be attributed to interventions with other LVAD. Possible reasons for bias were more frequent in small studies with high cross-over rates, early stopping and the inclusion of patients with IABP at randomisation. AUTHORS' CONCLUSIONS Available evidence suggests that IABP may have a beneficial effect on some haemodynamic parameters. However, this did not result in survival benefits so there is no convincing randomised data to support the use of IABP in infarct-related cardiogenic shock.
Collapse
Affiliation(s)
- Susanne Unverzagt
- Institute of Medical Epidemiology, Biostatistics and Informatics, Martin Luther University Halle-Wittenberg, Magdeburge Straße 8, Halle/Saale, Germany, 06097
| | | | | | | | | | | | | | | | | | | |
Collapse
|
34
|
Nowak-Machen M, Hilberath JN, Rosenberger P, Schmid E, Memtsoudis SG, Angermair J, Tuli JK, Shernan SK. Influence of intraaortic balloon pump counterpulsation on transesophageal echocardiography derived determinants of diastolic function. PLoS One 2015; 10:e0118788. [PMID: 25739068 PMCID: PMC4349649 DOI: 10.1371/journal.pone.0118788] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2014] [Accepted: 12/11/2014] [Indexed: 12/02/2022] Open
Abstract
Introduction Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively investigated. Acute diastolic dysfunction has been linked to increased morbidity and mortality. The aim of this study was to examine the influence of IABP on LV diastolic dysfunction using standard TEE derived parameters. Methods Intraoperative TEE was performed in 10 patients (mean age 65 ± 11 yrs) undergoing urgent coronary artery bypass graft surgery (CABG), who had received an IABP preoperatively. TEE derived measures of diastolic dysfunction included early to late transmitral Doppler inflow velocity ratio (E/A), deceleration time (Dt), pulmonary venous systolic to diastolic Doppler velocity ratio (S/D), transmitral propagation velocity (Vp), and the ratio of early to late mitral annular tissue Doppler velocities (e’/a’). Statistical analyses included the Wilcoxon Sign-Rank test, and a p<0.05 was considered significant. Results Transmitral inflow E/A ratios increased significantly from 0.86 to 1.07 (p < 0.05), while Dt decreased significantly from 218 to 180 ms (p < 0.05) with the use of IABP. Significant increases in Vp (34 cm/s to 43 cm/s; p < 0.05), and e’/a’ (0.58 to 0.71; p < 0.05) suggested a favourable influence of intraaortic counterpulsation on diastolic function. Conclusion The use of perioperative IABP significantly improves TEE derived parameters of diastolic function consistent with a favourable impact on LV relaxation in cardiac surgery patients undergoing CABG.
Collapse
Affiliation(s)
- Martina Nowak-Machen
- Klinik für Anaesthesiologie und Intensivmedizin, Universitätsklinikum Tübingen, Germany
- * E-mail:
| | - Jan N. Hilberath
- Klinik für Anaesthesiologie und Intensivmedizin, Universitätsklinikum Tübingen, Germany
- Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| | - Peter Rosenberger
- Klinik für Anaesthesiologie und Intensivmedizin, Universitätsklinikum Tübingen, Germany
| | - Eckhard Schmid
- Klinik für Anaesthesiologie und Intensivmedizin, Universitätsklinikum Tübingen, Germany
| | - Stavros G. Memtsoudis
- Department of Anesthesiology, Hospital for Special Surgery, Weill Cornell Medical College, New York, New York, United States of America
| | - Johannes Angermair
- Klinik für Anaesthesiologie und Intensivmedizin, Universitätsklinikum Tübingen, Germany
| | - Jayshree K. Tuli
- Department of Statistics, University of Toronto, Toronto, Canada
| | - Stanton K. Shernan
- Department of Anesthesiology, Perioperative and Pain Medicine, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
35
|
Myat A, Patel N, Tehrani S, Banning AP, Redwood SR, Bhatt DL. Percutaneous Circulatory Assist Devices for High-Risk Coronary Intervention. JACC Cardiovasc Interv 2015; 8:229-244. [DOI: 10.1016/j.jcin.2014.07.030] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/08/2014] [Accepted: 07/17/2014] [Indexed: 10/24/2022]
|
36
|
The efficacy and safety of mechanical hemodynamic support in patients undergoing high-risk percutaneous coronary intervention with or without cardiogenic shock: Bayesian approach network meta-analysis of 13 randomized controlled trials. Int J Cardiol 2015; 184:36-46. [PMID: 25697869 DOI: 10.1016/j.ijcard.2015.01.081] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2014] [Accepted: 01/24/2015] [Indexed: 11/20/2022]
Abstract
BACKGROUND Studies have reported conflicting results regarding efficacy of mechanical hemodynamic support using intra-aortic balloon pump (IABP) or percutaneous ventricular assisted device (pVAD) in patients undergoing high-risk PCI. We performed a Bayesian network meta-analysis comparing the safety and efficacy of mechanical hemodynamic support devices and medical therapy (MT). METHODS AND RESULTS RCTs comparing overall mortality of IABP versus MT or IABP versus pVAD in high-risk PCI populations were included. The primary endpoint was overall mortality, using the longest available follow-up in each study. This analysis included 2843 patients from 13 trials. In network meta-analysis, overall survival benefit was not significant with IABP (RR 0.84, 95% CrI 0.56-1.24) or pVAD (RR 0.95, 95% CrI 0.42-2.06), compared with MT. IABP or pVAD also did not show early survival benefit compared with MT. In terms of bleeding, pVAD was the worst (versus IABP: RR 29.4, 95% CrI 5.99-221.0; versus MT: RR 41.7, 95% CrI 8.19-330.0), which was mainly driven by the higher incidence of bleeding in the ECMO and TandemHeart, while IABP was worse than MT (RR 1.41, 95% CrI 1.01-2.08). The incidence of acute limb ischemia or vascular complication was not different between treatment groups. CONCLUSIONS In this meta-analysis, routine elective use of IABP or pVAD did not reduce mortality, while it increased bleeding, compared with MT in high-risk PCI population or even in the patients with cardiogenic shock. Thoughtful selection of appropriate patients and balancing the risk and benefit should be the prerequisites to the use of mechanical hemodynamic support devices.
Collapse
|
37
|
White JM, Ruygrok PN. Intra-aortic balloon counterpulsation in contemporary practice - where are we? Heart Lung Circ 2014; 24:335-41. [PMID: 25616681 DOI: 10.1016/j.hlc.2014.12.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Revised: 12/03/2014] [Accepted: 12/05/2014] [Indexed: 11/18/2022]
Abstract
The intra-aortic balloon pump (IABP) remains the most widely used form of mechanical circulatory support in current clinical practice. This article will review the current evidence to guide IABP use, focussing on large registry and prospective, randomised data, and seek to establish appropriate roles for the IABP in contemporary practice. Despite a paucity of clinical evidence, the IABP remains a useful clinical tool in selected settings, although its routine, up-front use in relatively unselected MI populations is not supported by data. Although current evidence no longer supports routine use in certain high-risk groups, further studies of appropriately selected high-risk patients may yet demonstrate benefit in patients with moderate-severe degrees of shock.
Collapse
Affiliation(s)
- Jonathon M White
- Green Lane Cardiovascular Service, Auckland City Hospital, Auckland, New Zealand
| | - Peter N Ruygrok
- Green Lane Cardiovascular Service, Auckland City Hospital, Auckland, New Zealand; University of Auckland School of Medicine, Auckland, New Zealand.
| |
Collapse
|
38
|
Kapelios CJ, Terrovitis JV, Nanas JN. Current and future applications of the intra-aortic balloon pump. Curr Opin Cardiol 2014; 29:258-65. [PMID: 24686399 DOI: 10.1097/hco.0000000000000059] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE OF REVIEW The intra-aortic balloon pump (IABP) has been used for more than 40 years. Although recommended in a wide variety of clinical settings, most of these indications are not evidence-based. This review focuses on studies challenging these traditional indications and evaluates potentially new applications of intra-aortic counterpulsation. RECENT FINDINGS Recent studies have failed to confirm an improvement in clinical outcomes conferred by the IABP in patients developing cardiogenic shock after acute myocardial infarction. This issue is in need of further investigations. While conflicting results of several retrospective studies and meta-analyses have been published regarding the performance of the IABP in high-risk percutaneous coronary interventions, it has recently been found to improve the long-term clinical outcomes of patients in whom it was implanted before the procedure. Small, single-center studies have reported the use of the IABP as a bridge to transplantation or candidacy for left-ventricular assist device implantation. The recently reported feasibility and safety of its insertion via the subclavian or axillary arteries will facilitate these applications. SUMMARY The revisiting of available data and the performance of new, thoughtfully designed trials should clarify the proper indications for the IABP.
Collapse
Affiliation(s)
- Chris J Kapelios
- The 3rd Department of Cardiology, University of Athens School of Medicine, Athens, Greece
| | | | | |
Collapse
|
39
|
Patterson T, Perera D, Redwood SR. Intra-Aortic Balloon Pump for High-Risk Percutaneous Coronary Intervention. Circ Cardiovasc Interv 2014; 7:712-20. [DOI: 10.1161/circinterventions.114.001258] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Affiliation(s)
- Tiffany Patterson
- From the Cardiovascular Division, Rayne Institute, British Heart Foundation Centre of Research Excellence, Kings College London, St Thomas’ Hospital, London, UK
| | - Divaka Perera
- From the Cardiovascular Division, Rayne Institute, British Heart Foundation Centre of Research Excellence, Kings College London, St Thomas’ Hospital, London, UK
| | - Simon R. Redwood
- From the Cardiovascular Division, Rayne Institute, British Heart Foundation Centre of Research Excellence, Kings College London, St Thomas’ Hospital, London, UK
| |
Collapse
|
40
|
Amsterdam EA, Wenger NK, Brindis RG, Casey DE, Ganiats TG, Holmes DR, Jaffe AS, Jneid H, Kelly RF, Kontos MC, Levine GN, Liebson PR, Mukherjee D, Peterson ED, Sabatine MS, Smalling RW, Zieman SJ. 2014 AHA/ACC Guideline for the Management of Patients with Non-ST-Elevation Acute Coronary Syndromes: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 2014; 64:e139-e228. [PMID: 25260718 DOI: 10.1016/j.jacc.2014.09.017] [Citation(s) in RCA: 2089] [Impact Index Per Article: 208.9] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
41
|
Amsterdam EA, Wenger NK, Brindis RG, Casey DE, Ganiats TG, Holmes DR, Jaffe AS, Jneid H, Kelly RF, Kontos MC, Levine GN, Liebson PR, Mukherjee D, Peterson ED, Sabatine MS, Smalling RW, Zieman SJ. 2014 AHA/ACC guideline for the management of patients with non-ST-elevation acute coronary syndromes: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. Circulation 2014; 130:e344-426. [PMID: 25249585 DOI: 10.1161/cir.0000000000000134] [Citation(s) in RCA: 636] [Impact Index Per Article: 63.6] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
42
|
Patel H, Shivaraju A, Fonarow GC, Xie H, Gao W, Shroff AR, Vidovich MI. Temporal trends in the use of intraaortic balloon pump associated with percutaneous coronary intervention in the United States, 1998-2008. Am Heart J 2014; 168:363-373.e12. [PMID: 25173549 DOI: 10.1016/j.ahj.2014.02.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/19/2013] [Accepted: 02/05/2014] [Indexed: 10/25/2022]
Abstract
BACKGROUND With conflicting evidence regarding the usefulness of intraaortic balloon pump (IABP), reports of IABP use in the United States have been inconsistent. Our objective was to examine trends in IABP usage in percutaneous coronary intervention (PCI) in the United States and to evaluate the association of IABP use with mortality. METHODS This is a retrospective, observational study using patient data obtained from the Nationwide Inpatient Sample database from 1998 to 2008. Patients undergoing any PCI (1,552,602 procedures) for a primary diagnosis of symptomatic coronary artery disease and acute coronary syndrome, including non-ST-elevation myocardial infarction and ST-elevation myocardial infarction, were evaluated. RESULTS The overall use of IABP significantly decreased during the study period from 0.99% in 1998 to 0.36% in 2008 (univariate and multivariate P for trend < .0001). Patients who received IABP had substantially higher rates of shock compared with those who did not receive IABP (38.09% vs 0.70%; P < .0001), which was associated with markedly higher inhospital mortality rates (20.31% vs 0.72%; P < .0001). However, IABP use significantly decreased in patients with shock (36.5%-13.4%) and acute myocardial infarction (2.23%-0.84%) (univariate and multivariate P for trend for both < .0001). A temporal reduction in all-cause PCI-associated mortality from 1.1% in 1998 to 0.86% in 2008 (univariate and multivariate P for trend < .0001) was also observed. CONCLUSIONS The utilization of IABP associated with PCI significantly decreased between 1998 and 2008 in the United States, even among patients with acute myocardial infarction and shock.
Collapse
|
43
|
Lisi E, Guida V, Blengino S, Pedrazzi E, Ossoli D, Parati G. Intra-aortic balloon pump for treatment of refractory ventricular tachycardia in Tako-Tsubo cardiomyopathy: a case report. Int J Cardiol 2014; 174:135-6. [PMID: 24739134 DOI: 10.1016/j.ijcard.2014.03.102] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2014] [Accepted: 03/14/2014] [Indexed: 11/26/2022]
Affiliation(s)
- Elisabetta Lisi
- Dept. of Cardiology, Istituto Auxologico Italiano, Milano, Italy; Dept. of Health Sciences, University of Milano-Bicocca, Milano, Italy
| | - Valentina Guida
- Dept. of Cardiology, Istituto Auxologico Italiano, Milano, Italy; Dept. of Health Sciences, University of Milano-Bicocca, Milano, Italy
| | | | | | - Deborah Ossoli
- Dept. of Cardiology, Istituto Auxologico Italiano, Milano, Italy
| | - Gianfranco Parati
- Dept. of Cardiology, Istituto Auxologico Italiano, Milano, Italy; Dept. of Health Sciences, University of Milano-Bicocca, Milano, Italy.
| |
Collapse
|
44
|
Lack of intra-aortic balloon pump effectiveness in high-risk percutaneous coronary interventions without cardiogenic shock: A comprehensive meta-analysis of randomised trials and observational studies. Int J Cardiol 2013; 167:1783-93. [DOI: 10.1016/j.ijcard.2012.12.027] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2012] [Revised: 10/09/2012] [Accepted: 12/08/2012] [Indexed: 11/20/2022]
|
45
|
Minha S, Fatemi O, Torguson R, Waksman R. Overview of the 2012 Food and Drug Administration circulatory system devices panel meeting on the reclassification of external counterpulsation, intra-aortic balloon pump, and non-roller-type cardiopulmonary bypass blood pump devices. Am Heart J 2013; 166:414-20. [PMID: 24016488 DOI: 10.1016/j.ahj.2013.07.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2013] [Accepted: 07/01/2013] [Indexed: 11/25/2022]
Abstract
The Food and Drug Administration held a Circulatory System Devices Advisory Panel meeting, December 5 and 6, 2012, to review the classification or potential reclassification of the following device types: external counterpulsation, intra-aortic balloon pump (IABP), and non-roller-type cardiopulmonary bypass blood pumps. These 3 devices are preamendment (Medical Device Amendments of 1976) class III devices. The advisory panel discussed the data and provided recommendations for reclassification of these devices. The panel recommended reclassification of ECP to class II for stable angina pectoris and to retain a class III for all other indications. For IABP, the recommendation was to reclassify IABP to class II for several indications (acute coronary syndrome, cardiac and noncardiac surgery, and heart failure complications) and remain class III for all other indications. As for non-roller type, the panel recommended that for cardiopulmonary bypass and temporary circulatory bypass, these devices should be reclassified to class II while retaining a class III device status for all other indications, including ventricular support both for hemodynamically unstable patients and for prophylactic support in high-risk percutaneous interventions.
Collapse
|
46
|
Usage of Percutaneous Left Ventricular Assist Devices in Clinical Practice and High-risk Percutaneous Coronary Intervention. Interv Cardiol Clin 2013; 2:417-428. [PMID: 28582103 DOI: 10.1016/j.iccl.2013.04.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Patients who require coronary revascularization and present with poor left ventricular function and complex coronary anatomy are at high risk for percutaneous coronary intervention (PCI) and coronary artery bypass grafting surgery. Some of these patients are poor surgical candidates because of previous cardiac surgery or significant comorbidities. The recent approval and availability of percutaneous left ventricular assist devices has created an opportunity for the highest risk patients. This article reviews currently available mechanical circulatory support systems and portable extracorporeal oxygenation, describing hemodynamic and physiologic rationales, indications, strategies, and available evidence for their use in high risk PCI.
Collapse
|
47
|
Anderson JL, Adams CD, Antman EM, Bridges CR, Califf RM, Casey DE, Chavey WE, Fesmire FM, Hochman JS, Levin TN, Lincoff AM, Peterson ED, Theroux P, Wenger NK, Wright RS, Zoghbi WA, Arend TE, Oetgen WJ, May C, Bradfield L, Keller S, Ramadhan E, Tomaselli GF, Brown N, Robertson RM, Whitman GR, Bezanson JL, Hundley J. 2012 ACCF/AHA Focused Update Incorporated Into the ACCF/AHA 2007 Guidelines for the Management of Patients With Unstable Angina/Non–ST-Elevation Myocardial Infarction. Circulation 2013; 127:e663-828. [DOI: 10.1161/cir.0b013e31828478ac] [Citation(s) in RCA: 181] [Impact Index Per Article: 16.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
48
|
Anderson JL, Adams CD, Antman EM, Bridges CR, Califf RM, Casey DE, Chavey WE, Fesmire FM, Hochman JS, Levin TN, Lincoff AM, Peterson ED, Theroux P, Wenger NK, Wright RS, Jneid H, Ettinger SM, Ganiats TG, Philippides GJ, Jacobs AK, Halperin JL, Albert NM, Creager MA, DeMets D, Guyton RA, Kushner FG, Ohman EM, Stevenson W, Yancy CW. 2012 ACCF/AHA focused update incorporated into the ACCF/AHA 2007 guidelines for the management of patients with unstable angina/non-ST-elevation myocardial infarction: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 2013; 61:e179-347. [PMID: 23639841 DOI: 10.1016/j.jacc.2013.01.014] [Citation(s) in RCA: 373] [Impact Index Per Article: 33.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
49
|
Li Z, Dong P, Liu X, Yang X, Wang K, Li Z, Zhao Y, Jin G, Li Z, Li C. Early application of an intra-aortic balloon pump in patients with ST-segment elevation acute myocardial infarction scheduled for elective percutaneous coronary intervention. J Int Med Res 2013; 41:754-61. [PMID: 23613498 DOI: 10.1177/0300060513476994] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE This study evaluated the effect of early application of intra-aortic balloon pump (IABP) counterpulsation in patients with ST-segment elevation acute myocardial infarction (STEMI), scheduled for elective percutaneous coronary intervention (PCI). METHODS Patients who had experienced STEMI for 12-72 h received (IABP group) or did not receive (control group) IABP counterpulsation for 3-5 days before PCI. RESULTS One hundred patients were included. Frequencies of infarct-related artery thrombolysis in acute myocardial infarction (TIMI) flow rate classes 0, I and II in the IABP group (11.5, 1.9 and 7.7%, respectively) were significantly lower than in the control group (29.1, 14.6 and 22.9%, respectively) before PCI. After PCI, the frequency of TIMI class III flow rate in the IABP group (96.2%) was significantly higher than that in the control group (81.3%). Four weeks after PCI, the left ventricular ejection fraction (LVEF) was significantly higher, and the incidence of major cardiac events was significantly lower, in the IABP group compared with the control group. CONCLUSIONS Early use of IABP counterpulsation in STEMI patients scheduled for PCI was effective, with a favourable safety profile. IABP counterpulsation reduced the incidence of major adverse cardiac events and improved LVEF. However, IABP devices must be used at an early stage, to obtain optimal results.
Collapse
Affiliation(s)
- Zhijuan Li
- Department of Cardiology, The First Affiliated Hospital of Henan Science and Technology University, Luoyang, China
| | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Perera D, Stables R, Clayton T, De Silva K, Lumley M, Clack L, Thomas M, Redwood S. Long-Term Mortality Data From the Balloon Pump–Assisted Coronary Intervention Study (BCIS-1). Circulation 2013; 127:207-12. [DOI: 10.1161/circulationaha.112.132209] [Citation(s) in RCA: 159] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Affiliation(s)
- Divaka Perera
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| | - Rod Stables
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| | - Tim Clayton
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| | - Kalpa De Silva
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| | - Matthew Lumley
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| | - Lucy Clack
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| | - Martyn Thomas
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| | - Simon Redwood
- From the Cardiovascular Division, Kings College London, London (D.P., K.D.S., M.L., L.C., M.T., S.R.); Liverpool Heart and Chest Hospital, Liverpool (R.S.); and London School of Hygiene and Tropical Medicine, London (T.C.), UK
| |
Collapse
|