1
|
Gregorini M, Mikutis G, Grass RN, Stark WJ. Small-Size Polymerase Chain Reaction Device with Improved Heat Transfer and Combined Feedforward/Feedback Control Strategy. Ind Eng Chem Res 2019. [DOI: 10.1021/acs.iecr.9b01209] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Michele Gregorini
- Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Gediminas Mikutis
- Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Robert N. Grass
- Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Wendelin J. Stark
- Institute for Chemical and Bioengineering, ETH Zurich, Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| |
Collapse
|
2
|
Li Z, Zhao J, Wu X, Zhu C, Liu Y, Wang A, Deng G, Zhu L. A rapid microfluidic platform with real-time fluorescence detection system for molecular diagnosis. BIOTECHNOL BIOTEC EQ 2019. [DOI: 10.1080/13102818.2018.1561211] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022] Open
Affiliation(s)
- Zhigang Li
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
- Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, PR China
| | - Jun Zhao
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
- Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, PR China
| | - Xiaosong Wu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
- Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, PR China
| | - Cancan Zhu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
- Science Island Branch of Graduate School, University of Science and Technology of China, Hefei, PR China
| | - Yong Liu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
| | - An Wang
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
| | - Guoqing Deng
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
| | - Ling Zhu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Anhui Provincial Engineering Technology Research Center for Biomedical Optical Instrument, Anhui Provincial Engineering Laboratory for Medical Optical Diagnosis & Treatment Technology and Instrument, Hefei, PR China
| |
Collapse
|
3
|
Qiu X, Chen D, Liu C, Mauk MG, Kientz T, Bau HH. A portable, integrated analyzer for microfluidic - based molecular analysis. Biomed Microdevices 2011; 13:809-17. [PMID: 21617995 PMCID: PMC12107625 DOI: 10.1007/s10544-011-9551-5] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
A portable, fully automated analyzer that provides actuation and flow control to a disposable, self-contained, microfluidic cassette ("chip") for point-of-care, molecular testing is described. The analyzer provides mechanical actuation to compress pouches that pump liquids in the cassette, to open and close diaphragm valves for flow control, and to induce vibrations that enhance stirring. The analyzer also provides thermal actuation for the temperature cycling needed for polymerase chain reaction (PCR) amplification of nucleic acids and for various drying processes. To improve the temperature uniformity of the PCR chamber, the system utilizes a double-sided heating/cooling scheme with a custom feedforward, variable, structural proportional-integral-derivative (FVSPID) controller. The analyzer includes a programmable central processing unit that directs the sequence and timing of the various operations and that is interfaced with a computer. The disposable cassette receives a sample, and it carries out cell lysis, nucleic acid isolation, concentration, and purification, thermal cycling, and either real time or lateral flow (LF) based detection. The system's operation was demonstrated by processing saliva samples spiked with B. cereus cells. The amplicons were detected with a lateral flow assay using upconverting phosphor reporter particles. This system is particularly suited for use in regions lacking centralized laboratory facilities and skilled personnel.
Collapse
Affiliation(s)
- Xianbo Qiu
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA 19104-6315
| | - Dafeng Chen
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA 19104-6315
| | - Changchun Liu
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA 19104-6315
| | - Michael G. Mauk
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA 19104-6315
| | - Terry Kientz
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA 19104-6315
| | - Haim H. Bau
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia PA 19104-6315
| |
Collapse
|
4
|
Abstract
A point-of-care, diagnostic system incorporating a portable thermal cycler and a compact fluorescent detector for real-time, polymerase chain reaction (PCR) on disposable, plastic microfluidic reactors with relatively large reaction volume (ranging from 10 µL to 100 µL) is described. To maintain temperature uniformity and a relatively fast temperature ramping rate, the system utilizes double-sided heater that features a master, thermoelectric element and a thermal waveguide connected to a second thermoelectric element. The waveguide has an aperture for optical coupling between a miniature, fluorescent reader and the PCR reaction chamber. The temperature control is accomplished with a modified, feedforward, variable structural proportional-integral-derivative controller. The temperature of the liquid in the reaction chamber tracks the set-point temperature with an accuracy of ± 0.1 °C. The transition times from one temperature to another are minimized with controllable overshoots (< 2 °C) and undershoots (< 5 °C). The disposable, single-use PCR chip can be quickly inserted into a thermal cycler/reader unit for point-of-care diagnostics applications. The large reaction chamber allows convenient pre-storing of dried, paraffin-encapsulated PCR reagents (polymerase, primers, dNTPs, dyes, and buffers) in the PCR chamber. The reagents are reconstituted "just in time" by heating during the PCR process. The system was tested with viral and bacterial nucleic acid targets.
Collapse
Affiliation(s)
- Xianbo Qiu
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, USA
| | - Michael G. Mauk
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, USA
| | - Dafeng Chen
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, USA
| | - Changchun Liu
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, USA
| | - Haim H. Bau
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, USA
| |
Collapse
|