1
|
DeWitt JM, Benton ER. Secondary proton buildup in space radiation shielding. LIFE SCIENCES IN SPACE RESEARCH 2024; 41:119-126. [PMID: 38670638 DOI: 10.1016/j.lssr.2024.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 02/06/2024] [Accepted: 02/15/2024] [Indexed: 04/28/2024]
Abstract
The risk posed by prolonged exposure to space radiation represents a significant obstacle to long-duration human space exploration. Of the ion species present in the galactic cosmic ray spectrum, relativistic protons are the most abundant and as such are a relevant point of interest with regard to the radiation protection of space crews involved in future long-term missions to the Moon, Mars, and beyond. This work compared the shielding effectiveness of a number of standard and composite materials relevant to the design and development of future spacecraft or planetary surface habitats. Absorbed dose was measured using Al2O3:C optically stimulated luminescence dosimeters behind shielding targets of varying composition and depth using the 1 GeV nominal energy proton beam available at the NASA Space Radiation Laboratory at the Brookhaven National Laboratory in New York. Absorbed dose scored from computer simulations performed using the multi-purpose Monte Carlo radiation transport code FLUKA agrees well with measurements obtained via the shielding experiments. All shielding materials tested and modeled in this study were unable to reduce absorbed dose below that measured by the (unshielded) front detector, even after depths as large as 30 g/cm2. These results could be noteworthy given the broad range of proton energies present in the galactic cosmic ray spectrum, and the potential health and safety hazard such space radiation could represent to future human space exploration.
Collapse
Affiliation(s)
- J M DeWitt
- Department of Physics, East Carolina University, Greenville, NC 27834, USA.
| | - E R Benton
- Department of Physics, Oklahoma State University, Stillwater, OK 74078, USA
| |
Collapse
|
2
|
Kodaira S, Kitamura H, Kurano M, Kawashima H, Benton ER. Contribution to dose in healthy tissue from secondary target fragments in therapeutic proton, He and C beams measured with CR-39 plastic nuclear track detectors. Sci Rep 2019; 9:3708. [PMID: 30842438 PMCID: PMC6403338 DOI: 10.1038/s41598-019-39598-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2018] [Accepted: 01/28/2019] [Indexed: 11/17/2022] Open
Abstract
The linear energy transfer (LET) spectrum, absorbed dose and dose equivalent from secondary particles of LET∞H2O ≥15 keV/μm deposited within the plateau of the Bragg curve in primary particle-induced nuclear target fragmentation reactions in tissue during proton and heavy ion radiotherapy were measured using CR-39 plastic nuclear track detectors and analyzed by means of atomic force microscopy. It was found that secondary target fragments contributed 20% to dose equivalent for primary protons (157 MeV), 13% for primary helium ions (145 MeV/n) and 4% for primary carbon ions (383 MeV/n), respectively. Little research has been done on the contribution from these particles to primary given dose. The smaller contribution measured for energetic carbon ion beams compared to proton beams can be considered an advantage of carbon ion radiotherapy over proton radiotherapy.
Collapse
Affiliation(s)
- Satoshi Kodaira
- Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.
| | - Hisashi Kitamura
- Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Mieko Kurano
- Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Hajime Kawashima
- Radiation Measurement Research Team, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan
| | - Eric R Benton
- Department of physics, Oklahoma State University, Stillwater, OK, United States
| |
Collapse
|
3
|
Measurement of target fragments produced by 160 MeV proton beam in aluminum and polyethylene with CR-39 plastic nuclear track detectors. RADIAT MEAS 2014. [DOI: 10.1016/j.radmeas.2014.04.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
4
|
Kodaira S, Yasuda N, Konishi T, Kitamura H, Kurano M, Kawashima H, Uchihori Y, Ogura K, Benton E. Calibration of CR-39 with atomic force microscope for the measurement of short range tracks from proton-induced target fragmentation reactions. RADIAT MEAS 2013. [DOI: 10.1016/j.radmeas.2012.10.001] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
5
|
Kodaira S, Kawashima H, Kitamura H, Kurano M, Uchihori Y, Yasuda N, Ogura K, Kobayashi I, Suzuki A, Koguchi Y, Akatov YA, Shurshakov VA, Tolochek RV, Krasheninnikova TK, Ukraintsev AD, Gureeva EA, Kuznetsov VN, Benton ER. Analysis of radiation dose variations measured by passive dosimeters onboard the International Space Station during the solar quiet period (2007–2008). RADIAT MEAS 2013. [DOI: 10.1016/j.radmeas.2012.11.020] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
6
|
Kodaira S, Yasuda N, Kawashima H, Kurano M, Naka S, Ota S, Ideguchi Y, Hasebe N, Ogura K. Detection threshold control of CR-39 plastic nuclear track detectors for the selective measurement of high LET secondary charged particles. RADIAT MEAS 2011. [DOI: 10.1016/j.radmeas.2011.08.015] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
7
|
Benton E, Johnson C, DeWitt J, Yasuda N, Benton E, Moyers M, Frank A. Observations of short-range, high-LET recoil tracks in CR-39 plastic nuclear track detector by visible light microscopy. RADIAT MEAS 2011. [DOI: 10.1016/j.radmeas.2011.03.013] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
8
|
Abstract
Passive radiation dosimeters were exposed aboard the Mir Orbital Station over a substantial portion of the solar cycle in order to measure the change in dose and dose equivalent rates as a function of time. During solar minimum, simultaneous measurements of the radiation environment throughout the habitable volume of the Mir were made using passive dosimeters in order to investigate the effect of localized shielding on dose and dose equivalent. The passive dosimeters consisted of a combination of thermoluminescent detectors to measure absorbed dose and CR-39 PNTDs to measure the linear energy transfer (LET) spectrum from charged particles of LET infinity H2O > or = 5 keV/micrometers. Results from the two detector types were then combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Contrary to expectations, both dose and dose equivalent rates measured during May-October 1991 near solar maximum were higher than similar measurements carried out in 1996-1997 during solar minimum. The elevated dose and dose equivalent rates measured in 1991 were probably due to a combination of intense solar activity, including a large solar particle event on 9 June 1991, and the temporary trapped radiation belt created in the slot region by the solar particle event and ensuing magnetic storm of 24 March 1991. During solar minimum, mean dose and dose equivalent rates were found to vary by factors of 1.55 and 1.37, respectively, between different locations through the interior of Mir. More heavily shielded locations tended to yield lower total dose and dose equivalent rates, but higher average quality factor than did more lightly shielding locations. However, other factors such as changes in the immediate shielding environment surrounding a given detector location, changes in the orientation of the Mir relative to its velocity vector, and changes in the altitude of the station also contributed to the variation. Proton and neutron-induced target fragment secondaries, not primary galactic cosmic rays, were found to dominate the LET spectrum above 100 keV/micrometers. This indicates that in low earth orbit, trapped protons in the South Atlantic Anomaly are responsible for the major fraction of the total dose equivalent.
Collapse
Affiliation(s)
- E R Benton
- Eril Research, Inc., San Rafael, CA 94915-0788, USA.
| | | | | |
Collapse
|
9
|
Abstract
This paper reports results from the first measurements made on the exterior of a LEO spacecraft of mean dose equivalent rate and average quality factor as functions of shielding depth for shielding less than 1 g/cm2 Al equivalent. Two sets of measurements were made on the outside of the Mir Orbital Station; one near solar maximum in June 1991 and one near solar minimum in 1997. Absorbed dose was measured using stacks of TLDs. LET spectrum from charged particles of LET infinity H2O > o r= 5keV/micrometers was measured using stacks of CR-39 PNTDs. Results from the TLD and PNTD measurements at a given shielding depth were combined to yield mean total dose rate, mean dose equivalent rate, and average quality factor. Measurements made near solar maximum tend to be greater than those made during solar minimum. Both mean dose rate and mean dose equivalent rate decrease by nearly four orders of magnitude within the first g/cm2 shielding illustrating the attenuation of both trapped electrons and low-energy trapped protons. In order to overcome problems with detector saturation after standard chemical processing, measurement of LET spectrum in the least shielded CR-39 PNTD layer (0.005 g/cm2 Al) was carried out using an atomic force microscope.
Collapse
Affiliation(s)
- E R Benton
- Eril Research, Inc., San Rafael, CA 94915-0788, USA.
| | | | | |
Collapse
|
10
|
Tawara H, Doke T, Hayashi T, Kikuchi J, Kyan A, Nagaoka S, Nakano T, Takahashi S, Terasawa K, Yoshihira E. LET distributions from CR-39 plates on Space Shuttle missions STS-84 and STS-91 and a comparison of the results of the CR-39 plates with those of RRMD-II and RRMD-III telescopes. RADIAT MEAS 2002; 35:119-26. [PMID: 11841106 DOI: 10.1016/s1350-4487(01)00282-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The LET distributions during the Space Shuttle missions STS-84 (altitude 270-412 km, average 375 km; inclination angle, 51.6 degrees) and STS-91 (altitude 328-397 km, average 373 km; inclination angle, 51.6 degrees) were measured using CR-39 plastic nuclear track detectors. A correction for the dip-angle dependence of the track-formation sensitivity of the CR-39 plates was applied to the data analysis. The absorbed doses and the dose equivalents around RRMD Detector Units, estimated from the LET distributions in the LET region of 4-200 keV/micrometers, fluctuated with standard deviations of +/- 21% to +/- 35% in both flight experiments. The LET distributions obtained from the CR-39 plates agreed well with that obtained from RRMD-II in STS-91. However, the particle fluxes obtained from RRMD-III in STS-84 and STS-91 were two or three times higher than those obtained from RRMD-II and the CR-39 plates. It was concluded that the LET distributions obtained from RRMD-II and the CR-39 plates in the present flight experiments did not include the contribution of target-fragmented secondary heavy particles produced by low-LET particles, such as relativistic or semi-relativistic protons and helium ions, whereas RRMD-III was able to detect these secondary particles because of its low triggering level.
Collapse
Affiliation(s)
- H Tawara
- High Energy Accelerator Research Organization, Radiation Science Center, Oho 1-1, Tsukuba-shi, Ibaraki 305-0801, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Benton EV, Frank AL, Csige I, Frigo LA, Benton ER. LET spectra measurements on LDEF: variations with shielding and location. RADIAT MEAS 1996; 26:783-91. [PMID: 11540510 DOI: 10.1016/s1350-4487(96)00085-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
LET spectra measurements made with passive plastic nuclear track detectors (PNTDs) were found to depend on detector orientation, shielding and experiment location. LET spectra were measured at several locations on LDEF as part of the P0006 LETSME experiment (Benton and Parnell, 1984), the P0004 Seeds in Space experiment (Parks and Alston, 1984), the A00l5 Free Flyer Biostacks and the M0004 Fiber Optics Data Link experiment (Taylor, 1984). Locations included the east, west and Earth sides of the LDEF satellite. The LET spectra measured with PNTDs deviated significantly from calculations, especially for high LET particles (LET infinity H2O > or = 100 keV/micrometer). At high LETs, short-range inelastic secondary particles produced by trapped proton interactions with the nuclei of the detector were found to be the principal contributor to LET spectra. At lower LETs, the spectra appeared to be due to short-range, inelastic and stopping primary protons, with primary GCR particles making a smaller contribution. The dependence of LET spectra on detector orientation and shielding was studied using the four orthogonal stacks in the P0006 experiment. Both measurements of total track density and LET spectra showed a greater number of particles arriving from the direction of space than from Earth. Measurements of LET spectra in CR-39 PNTD on the east (leading) and west (trailing) sides of LDEF showed a higher rate of production at the west side. This was caused by a larger flux of trapped protons on the west side as predicted by the east/west trapped proton anisotropy in the South Atlantic Anomaly (SAA). Track density measured in CR-39 PNTDs increased as a function of shielding depth in the detector stack. A similar measurement made in a thick stack of CR-39 interspersed with layers of Al and exposed to 154 MeV protons at a ground-based accelerator showed a similar result, indicating that a significant fraction of the particle events counted were from secondaries and that the total cross-section for production of proton-induced secondaries increased as the energy of primary protons attenuated. Little change was seen in either total differential or integral LET spectra as a function of shielding depth, indicating that the increase in cross section with decreasing proton energy affected mostly the shorter range secondary components. Similarity in the slopes of LET spectra from ground-based proton exposures and the A00l5 LET spectra showed that modeling of a monoenergetic proton beam transported through a 1-D geometry was a useful first step in modeling the production of secondary particles by trapped protons in the SAA.
Collapse
Affiliation(s)
- E V Benton
- Physics Research Laboratory, University of San Francisco, CA 94117-1080, USA
| | | | | | | | | |
Collapse
|