1
|
Wolffsohn JS, Berkow D, Chan KY, Chaurasiya SK, Fadel D, Haddad M, Imane T, Jones L, Sheppard AL, Vianya-Estopa M, Walsh K, Woods J, Zeri F, Morgan PB. BCLA CLEAR Presbyopia: Evaluation and diagnosis. Cont Lens Anterior Eye 2024; 47:102156. [PMID: 38641525 DOI: 10.1016/j.clae.2024.102156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/21/2024]
Abstract
It is important to be able to measure the range of clear focus in clinical practice to advise on presbyopia correction techniques and to optimise the correction power. Both subjective and objective techniques are necessary: subjective techniques (such as patient reported outcome questionnaires and defocus curves) assess the impact of presbyopia on a patient and how the combination of residual objective accommodation and their natural DoF work for them; objective techniques (such as autorefraction, corneal topography and lens imaging) allow the clinician to understand how well a technique is working optically and whether it is the right choice or how adjustments can be made to optimise performance. Techniques to assess visual performance and adverse effects must be carefully conducted to gain a reliable end-point, considering the target size, contrast and illumination. Objective techniques are generally more reliable, can help to explain unexpected subjective results and imaging can be a powerful communication tool with patients. A clear diagnosis, excluding factors such as binocular vision issues or digital eye strain that can also cause similar symptoms, is critical for the patient to understand and adapt to presbyopia. Some corrective options are more permanent, such as implanted inlays / intraocular lenses or laser refractive surgery, so the optics can be trialled with contact lenses in advance (including differences between the eyes) to better communicate with the patient how the optics will work for them so they can make an informed choice.
Collapse
Affiliation(s)
- James S Wolffsohn
- School of Optometry, Health and Life Sciences, Aston University, Birmingham, United Kingdom.
| | - David Berkow
- Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel
| | - Ka Yin Chan
- Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - Suraj K Chaurasiya
- Department of Contact Lens and Anterior Segment, CL Gupta Eye Institute, Moradabad, India; Department of Optometry and Vision Science, CL Gupta Eye Institute, Moradabad, India
| | - Daddi Fadel
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Mera Haddad
- Faculty of Applied Medical Sciences, Department of Allied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
| | - Tarib Imane
- Department of Ophthalmology and Visual Sciences, Illinois Eye and Ear Infirmary, College of Medicine, University of Illinois at Chicago, United States
| | - Lyndon Jones
- Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong; Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Amy L Sheppard
- School of Optometry, Health and Life Sciences, Aston University, Birmingham, United Kingdom
| | - Marta Vianya-Estopa
- Vision and Hearing Research Centre, Anglia Ruskin University, Cambridge, United Kingdom
| | - Karen Walsh
- CooperVision Inc., San Ramon, CA, United States
| | - Jill Woods
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fabrizio Zeri
- School of Optometry, Health and Life Sciences, Aston University, Birmingham, United Kingdom; University of Milano-Bicocca, Department of Materials Science, Milan, Italy
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, United Kingdom
| |
Collapse
|
2
|
Alsaqr AM, Alasmi AM, Fagehi R, Ali A. Perception and awareness of the public about presbyopia and its corrective approaches in Saudi Arabia: a population-based survey. BMC Public Health 2024; 24:1950. [PMID: 39033287 PMCID: PMC11265060 DOI: 10.1186/s12889-024-19508-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2023] [Accepted: 07/16/2024] [Indexed: 07/23/2024] Open
Abstract
BACKGROUND This study investigated patients' awareness of presbyopia and its management approaches and their preferred methods for near vision correction. METHODS In Saudi Arabia, 785 participants (aged between 35 and 60 years) completed a structured survey online, consisting of hard copies and direct interviews. The survey consisted of twenty-eight items divided into three parts. It was designed to record participants' awareness of and preferences for presbyopia and its refractive corrections. Nonparametric tests and descriptive analyses were conducted to analyse participants' responses. RESULT Approximately half of the participants had difficulty with near vision activities, such as reading newspapers or using mobile phones. Among all the participants, 76% were not aware of presbyopia. The prevalence of uncorrected presbyopia was 48% of the 785. The majority (82%) felt that spectacles were acceptable for correction of presbyopia. Most reported that they did not experience social stigma when using reading spectacles (87% of participants). When asked if they were aware of management approaches other than spectacles, 72% responded with not at all. Most participants had no earlier knowledge of the use of multifocal contact lenses or eye drops for presbyopia correction (67% and 82%, respectively). In the present study, some tendencies to use corrective approaches to presbyopia other than spectacles were noted. Finally, participants' age, sex, region, education, and income had a statistically significant impact on essential parts of their responses (p < 0.05). CONCLUSION Presbyopia is a highly prevalent age-related ocular disorder, and a significant percentage of cases are uncorrected due to a lack of awareness or reluctance to wear spectacles. More efficient health education about presbyopia and its corrective alternatives is urgently needed.
Collapse
Affiliation(s)
- Ali M Alsaqr
- Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
| | - Abdulrahman M Alasmi
- Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Raied Fagehi
- Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| | - Abusharha Ali
- Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia
| |
Collapse
|
3
|
Kim DY, Ahn H, Lee S, Jun I, Seo KY, Kim SY, Kim TI. Efficacy of a new refractive multifocal contact lens for presbyopia. Sci Rep 2024; 14:8878. [PMID: 38632261 PMCID: PMC11024154 DOI: 10.1038/s41598-024-55918-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 02/28/2024] [Indexed: 04/19/2024] Open
Abstract
This prospective single-arm study aimed to evaluate the clinical efficacy and safety of a refractive multifocal contact lens for the correction of presbyopia in 22 patients. The participants underwent clinical examinations before and 1 week after wearing a refractive multifocal contact lens (OptaCon ZOOM). The primary endpoints were the corrected distance visual acuity (CDVA) and distance-corrected near visual acuity (DCNVA). Defocus curve, contrast sensitivity, and ocular surface disease index (OSDI) were analyzed. A slit-lamp examination was performed for safety analysis. Contact lens comfort and patient satisfaction were assessed using a questionnaire. No significant difference in CDVA was observed before and 1 week after refractive multifocal contact lens use (p = 0.127), whereas DCNVA was significantly improved after 1 week (p < 0.001). The contrast sensitivity was not significantly affected at any spatial frequency under mesopic or photopic conditions. OSDI was significantly increased (p = 0.023). The patient-reported satisfaction scores were 96.2, 91.9, and 85.0 out of 100 at far, intermediate, and near distances, respectively. No significant adverse events were observed. Refractive multifocal contact lenses improved near vision while maintaining distance vision in presbyopic patients, without compromising contrast sensitivity. The study results suggest that OptaCon ZOOM can be considered safe and effective for the correction of presbyopia.
Collapse
Affiliation(s)
- Do Young Kim
- Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
- Siloam Eye Hospital, Seoul, Republic of Korea
| | - Hyunmin Ahn
- Eyejun Ophthalmic Clinic, Seoul, Republic of Korea
| | - Sukyung Lee
- Yonsei Plus Eye Center, Seongnam, Republic of Korea
| | - Ikhyun Jun
- Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | - Kyoung Yul Seo
- Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea
| | | | - Tae-Im Kim
- Department of Ophthalmology, Severance Hospital, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Korea.
| |
Collapse
|
4
|
Albero-Ros E, Lorente-Velázquez A, González-Pérez M. Content development for a new item-bank for measuring multifocal contact lens performance. J Patient Rep Outcomes 2024; 8:16. [PMID: 38329635 PMCID: PMC10853121 DOI: 10.1186/s41687-024-00689-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 01/18/2024] [Indexed: 02/09/2024] Open
Abstract
BACKGROUND Presbyopia is an age-related condition that causes a decreased ability to focus on nearby objects. Multifocal contact lenses are commonly used to address this issue. However, there seems to be a notable dissatisfaction among multifocal contact lens wearers. The absence of a reliable instrument to measure the patient's perspective, despite the widespread use of this method, highlights the need for further research in this area. OBJECTIVE The objective of this study is to develop an item-bank integrating all domains necessary to assess the patient's perspective on multifocal contact lens performance, offering a comprehensive measure. The item-bank will ensure a high level of content validity, be self-administered, and will initially be available in Spanish. The aim of this tool is to serve as a valuable resource for research and optometric clinics, facilitating the follow-up of patients with presbyopia who wear multifocal contact lenses or those who are newly starting to use them. METHODOLOGY The MCL-PRO item bank, followed a systematic and step-wise inductive approach to gather information, following the recommendations outlined in the COSMIN guidelines and similar studies. The process involved the following steps: (1) Literature review and relevant existing items identification (2) Social media review, (3) Semi-structured focus groups, (4) performing qualitative analysis, (5) refining and revising the items, and (6) generating the content of the item bank. RESULTS A total of 575 items were included in the item-bank hosted under 8 different domains that were found to be important for presbyopic population: visual symptoms (213), activity limitation (111), ocular symptoms (135), convenience (36), emotional well-being (33), general symptoms (16), cognitive issues (21) and economic issues (10). CONCLUSION The item-bank created has followed standardised methodology for its development and encloses all the aspects for MCL performance evaluation from patients perspective.
Collapse
Affiliation(s)
- Elsa Albero-Ros
- Department of Optometry and Vision, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Arcos de Jalón, 118, 28037, Madrid, Spain.
- Alain Afflelou Óptico, Portugal, Av. António Augusto de Aguiar, 11, 1050-016, Lisbon, Portugal.
| | - Amalia Lorente-Velázquez
- Department of Optometry and Vision, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Arcos de Jalón, 118, 28037, Madrid, Spain
- Clinical and Experimental Research Group (CEER), Faculty of Optics and Optometry, Universidad Complutense de Madrid, Arcos de Jalón, 118, 28037, Madrid, Spain
| | - Mariano González-Pérez
- Department of Optometry and Vision, Faculty of Optics and Optometry, Universidad Complutense de Madrid, Arcos de Jalón, 118, 28037, Madrid, Spain
- Clinical and Experimental Research Group (CEER), Faculty of Optics and Optometry, Universidad Complutense de Madrid, Arcos de Jalón, 118, 28037, Madrid, Spain
| |
Collapse
|
5
|
Barcala X, Vinas M, Ruiz S, Hidalgo F, Nankivil D, Karkkainen T, Gambra E, Dorronsoro C, Marcos S. Multifocal contact lens vision simulated with a clinical binocular simulator. Cont Lens Anterior Eye 2022; 45:101716. [PMID: 35606298 PMCID: PMC12077379 DOI: 10.1016/j.clae.2022.101716] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2021] [Revised: 05/05/2022] [Accepted: 05/09/2022] [Indexed: 11/23/2022]
Abstract
PURPOSE The purpose of this study is to compare the binocular visual perception of participants wearing multifocal contact lenses and these same lens designs viewed through a temporal multiplexing visual simulator. METHODS Visual performance and perceived visual quality at various distances were obtained in 37 participants wearing soft M-CLs and through the SimVis Gekko programmed with the same lenses. In a pilot study (n = 10) visual performance was measured in terms of LogMAR visual acuity (VA) at far (4 m), intermediate (64 cm) and near (40 cm) distances and through-focus VA (TFVA) curves with the simulated M-CLs. In the follow-up study (n = 27), LogMAR VA at far, intermediate and near distances were measured both with the actual and simulated M-CLs. Perceived visual quality was measured in both studies using the Multifocal Acceptance Score (MAS-2EV), and a Participants Reported Outcomes Vision questionnaire. Differences between the metrics obtained with simulated and actual lenses were obtained. RESULTS Both actual and simulated M-CLs increased depth-of-focus by a similar amount. Mean LogMAR VA differences with actual and simulated M-CLs ranged between 4 and 6 letters (0.08 ± 0.01, 0.12 ± 0.01 and 0.10 ± 0.01, for far, intermediate and near distances, respectively). MAS-2EV average score differences with actual and simulated M-CLs ranged between -1.00 and + 4.25. Average MAS-2EV scores were not correlated significantly with VA. However, MAS-2EV (average and individual scores) were highly correlated to visual quality questionnaire responses (p < 0.005). CONCLUSIONS A simultaneous vision simulator accurately represented vision with M-CLs both VA at various distances and perceived visual quality, as measured in a clinical setting. The MAS-2EV metric accurately captured participant reported outcomes of standard vision questionnaires. The combination of SimVis Gekko and MAS-2EV has the potential to largely reduce chair time in M-CLs fitting.
Collapse
Affiliation(s)
- Xoana Barcala
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain; 2EyesVision SL, Madrid, Spain.
| | - Maria Vinas
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain; Wellman Center for Photomedicine, Massachusetts General Hospital. Harvard Medical School, United States
| | - Sofia Ruiz
- Centro Boston de Optometría, Madrid, Spain
| | | | - Derek Nankivil
- Design Center of Excellence, Research & Development, Johnson & Johnson Vision Care Inc., Jacksonville, FL, United States
| | - Tom Karkkainen
- Clinical Sciences, Research & Development, Johnson & Johnson Vision Care Inc., Jacksonville, FL, United States
| | | | - Carlos Dorronsoro
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain; 2EyesVision SL, Madrid, Spain
| | - Susana Marcos
- Institute of Optics, Spanish National Research Council, IO-CSIC, Madrid, Spain; Center for Visual Science, The Institute of Optics, Flaum Eye Institute, University of Rochester, NY, United States.
| |
Collapse
|
6
|
Elmadina AEM. Progressive addition lenses wearers’ visual satisfaction among Saudi population. AFRICAN VISION AND EYE HEALTH 2022; 81. [DOI: 10.4102/aveh.v81i1.733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023] Open
|
7
|
Abstract
There are close to two billion individuals globally living with presbyopia. In spite of its ubiquitous and progressive nature, there is no widely accepted, formal guideline or consensus statement on the classification of presbyopia by degree of severity. A panel of leading eye care professionals representing both optometrists and ophthalmologists convened virtually to discuss and document their combined assessments from the body of literature and clinical practice expertise in this commentary. In light of emerging therapies, classifying presbyopia by mild, moderate, or advanced severity may help provide consistency of diagnosis among eye care providers and may aid in managing patient expectations with different treatment options.
Collapse
|
8
|
Wolffsohn JS, Dumbleton K, Huntjens B, Kandel H, Koh S, Kunnen CME, Nagra M, Pult H, Sulley AL, Vianya-Estopa M, Walsh K, Wong S, Stapleton F. CLEAR - Evidence-based contact lens practice. Cont Lens Anterior Eye 2021; 44:368-397. [PMID: 33775383 DOI: 10.1016/j.clae.2021.02.008] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Evidence-based contact lens -->practice involves finding, appraising and applying research findings as the basis for patient management decisions. These decisions should be informed by the strength of the research study designs that address the question, as well as by the experience of the practitioner and the preferences and environment of the patient. This reports reviews and summarises the published research evidence that is available to inform soft and rigid contact lens history and symptoms taking, anterior eye health examination (including the optimised use of ophthalmic dyes, grading scales, imaging techniques and lid eversion), considerations for contact lens selection (including the ocular surface measurements required to select the most appropriate lens parameter, lens modality and material selection), evaluation of lens fit, prescribing (teaching self-application and removal, adaptation, care regimen and cleaning instructions, as well as -->minimising risks of lens wear through encouraging compliance) and an aftercare routine.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- School of Optometry, University of California, Berkeley, CA, USA
| | - Byki Huntjens
- Division of Optometry and Visual Sciences at City, University of London, London, UK
| | - Himal Kandel
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Japan
| | | | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Cambridge, UK
| | - Heiko Pult
- Optometry and Vision Research, Weinheim, Germany
| | | | - Marta Vianya-Estopa
- Department of Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Karen Walsh
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Stephanie Wong
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
9
|
Bifocal and Multifocal Contact Lenses for Presbyopia and Myopia Control. J Ophthalmol 2020; 2020:8067657. [PMID: 32318285 PMCID: PMC7152962 DOI: 10.1155/2020/8067657] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2019] [Revised: 02/10/2020] [Accepted: 02/24/2020] [Indexed: 02/07/2023] Open
Abstract
Bifocal and multifocal optical devices are intended to get images into focus from objects placed at different distances from the observer. Spectacles, contact lenses, and intraocular lenses can meet the requirements to provide such a solution. Contact lenses provide unique characteristics as a platform for implementing bifocality and multifocality. Compared to spectacles, they are closer to the eye, providing a wider field of view, less distortion, and their use is more consistent as they are not so easily removed along the day. In addition, contact lenses are also minimally invasive, can be easily exchangeable, and, therefore, suitable for conditions in which surgical procedures are not indicated. Contact lenses can remain centered with the eye despite eye movements, providing the possibility for simultaneous imaging from different object distances. The main current indications for bifocal and multifocal contact lenses include presbyopia correction in adult population and myopia control in children. Considering the large numbers of potential candidates for optical correction of presbyopia and the demographic trends in myopia, the potential impact of contact lenses for presbyopia and myopia applications is undoubtedly tremendous. However, the ocular characteristics and expectations vary significantly between young and older candidates and impose different challenges in fitting bifocal and multifocal contact lenses for the correction of presbyopia and myopia control. This review presents the recent developments in material platforms, optical designs, simulated visual performance, and the clinical performance assessment of bifocal and multifocal contact lenses for presbyopia correction and/or myopia progression control.
Collapse
|
10
|
Visual Performance of Daily-disposable Multifocal Soft Contact Lenses: A Randomized, Double-blind Clinical Trial. Optom Vis Sci 2019; 95:1096-1104. [PMID: 30451806 DOI: 10.1097/opx.0000000000001311] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE The present study highlights the differences between modern daily-disposable multifocal soft contact lenses to assist eye care practitioners in fitting presbyopic contact lens wearers. PURPOSE The purpose of this study was to compare visual performance of three daily-disposable multifocal contact lenses. METHODS Presbyopes (n = 72) wore 1-Day Acuvue Moist Multifocal, BioTrue ONEday for Presbyopia, and Dailies AquaComfort Plus Multifocal for 1 week in a prospective, randomized, double-blind, crossover clinical trial. After 1 week, high- and low-contrast visual acuities (HCVA, LCVA) were measured between 6 m and 40 cm and stereopsis at 40 cm. Subjective performance was assessed with 1- to 10-point rating scales for clarity, ghosting, driving vision, vision stability, ease of focusing, overall vision satisfaction, and ocular comfort. Willingness to purchase was reported with categorical responses. Linear mixed models and χ tests were used for analysis, and level of significance was set at 5%. RESULTS BioTrue provided better HCVA and LCVA at distance than did Acuvue Moist (P ≤ .03). Subjectively, Acuvue Moist was rated lowest for distance clarity, distance ghosting, and driving vision (P ≤ .05). Acuvue Moist provided better HCVA at 70 to 40 cm and LCVA at 1 m to 40 cm than did BioTrue (P ≤ .01) and better LCVA at 1 m to 50 cm than did AquaComfort Plus (P ≤ .02). AquaComfort Plus also provided better HCVA and LCVA at 50 and 40 cm than did BioTrue (P ≤ .03). Acuvue Moist provided better stereopsis than did BioTrue (P = .02). Subjectively, BioTrue was rated lowest for near clarity (P ≤ .007) and lower than Acuvue Moist for intermediate clarity and near ghosting (P ≤ .04). No other differences were found between lenses (P > .05). CONCLUSIONS BioTrue had better distance performance compared with near, whereas Acuvue Moist performed conversely. AquaComfort Plus performed reasonably overall.
Collapse
|
11
|
Combined Effect of Ocular and Multifocal Contact Lens Induced Aberrations on Visual Performance: Center-Distance Versus Center-Near Design. Eye Contact Lens 2018; 44 Suppl 1:S131-S137. [PMID: 28060146 DOI: 10.1097/icl.0000000000000355] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the combined effects of inherent ocular aberrations and induced aberrations with a multifocal soft contact lens (MFCL) after 15 days of lens wear in presbyopic participants and their influence on visual performance at distance and near under high and low contrast conditions. METHODS Forty presbyopic participants (mean age, 48.7±3.4) presenting a mean addition of 1.53±0.58 D were fitted with Biofinity Multifocal (CooperVision) and included in the study. Measurements comprised distance and near monocular high (100%) and low contrast (10%) logMAR visual acuity (VA). Ocular aberrations were obtained with Hartmann-Shack aberrometer (IRX3, Imagine Eyes) and analyzed for 2 mm and maximum round natural pupil. RESULTS Distance VA was significantly higher in dominant eye, whereas near VA was significantly better in the non-dominant eye (P<0.05 in all conditions). For a 2-mm pupil in the dominant eye fitted with MFCL, spherical-like aberration significantly increased (P=0.027) so as higher-order aberrations (HOA) (P=0.002). A significant increase was also observed in spherical-like aberrations (P=0.001), coma-like aberrations (P=0.006) and HOA (P=0.004) in non-dominant eye. For the maximum round natural pupil size, a significant decrease in vertical coma was observed (P=0.018) in dominant eye, whereas a significant increase in spherical-like (P<0.001) and coma-like aberrations (P=0.007) was observed in non-dominant eye. A negative significant correlation was found between vertical coma and high contrast VA (Rho=-0.405, P=0.011) in dominant eye; whereas in non-dominant eye, a significant correlation was found between induced secondary astigmatism and distance VA under high (Rho=0.556, P<0.001) and low contrast (Rho=0.448, P=0.005). CONCLUSIONS On-eye visual performance of MFSCL is dependent on the high-order aberrations induced by dominant and non-dominant design coupled with the wearer's inherent aberrations.
Collapse
|
12
|
Abstract
OBJECTIVE To investigate if initial multifocal contact lens (MFCL) performance predicts short-term dispensing performance. METHODS A retrospective analysis of 55 participants (Px) in a masked, crossover, clinical trial, using ACUVUE OASYS for Presbyopia and AIR OPTIX AQUA Multifocal. Subjective questionnaires were administered at the following instances: initial fitting, two take home questionnaires (THQ) completed between days 2 and 4 and at assessment, ≥5 days after fitting. Questionnaires included vision clarity and lack of ghosting at distance, intermediate and near at day/night time points rated on a 1 to 10 (1-step, 10 most favorable) rating scale. Vision stability, vision while driving, overall vision satisfaction, willingness to purchase and comfort, as well as acuity-based measures were also collected. RESULTS There were no statistical differences in comfort and vision at all distances, in vision stability or driving at either time points between THQ and assessment (P>0.05). However, there was a statistical decline in subjective overall vision satisfaction and comfort between fitting and assessment visits (P<0.001). Willingness to purchase remained the same at fitting and assessment in 68% of Px, whereas only 4% of Px converted to a positive willingness to purchase at assessment. The majority of acuity-based measures remained constant between fitting and assessment visits. CONCLUSION Initial performance at fitting was not able to predict short-term performance of MFCL. Subjective measures peaked at fitting and declined thereafter whereas acuity-based measures remained constant. Utility of subjective rating tools may aid practitioners to gauge success of MFCL.
Collapse
|
13
|
Novillo-Díaz E, Villa-Collar C, Narváez-Peña M, Martín JLR. Fitting success for three multifocal designs: Multicentre randomised trial. Cont Lens Anterior Eye 2017; 41:258-262. [PMID: 29258836 DOI: 10.1016/j.clae.2017.12.012] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2017] [Revised: 12/04/2017] [Accepted: 12/05/2017] [Indexed: 11/28/2022]
Abstract
PURPOSE To determine if the discontinuation of commercially-available simultaneous vision Multifocal Soft Contact Lenses is independent from the multifocal design. To determine causes for discontinuation and psychosocial factors involved. METHODS Multicentre single-blinded randomised controlled trial with external blinded evaluation for a three months follow-up period for three intervention groups. 150 single-vision soft wearers were randomly assigned a spherical near centred lens (S-CN), distance centred lens (CD) or aspherical near centred lens (A-CN). Cases of discontinuation, anxiety and quality of life were measured at one week and one month. RESULTS 120 females and 30 males were included with an age range of 40-62 (48.79 ± 5.23). At one month, the S-CN design had a statistically significant higher risk of discontinuation than the other two OR: 6.12 (95%CI 2.5-14.9). Twenty-eight subjects discontinued wearing S-CN at first week (56%), while discontinuation of CD and A-CD were 15 (30%) and 11 (22%), with a statistically significant difference between S-CN design and the other two (p = 0.001). There were not statistically significant differences when direct comparison between discontinuation of CD and A-CN was made (p = 0.36). Thirty-two percent discontinued the use because of poor distance vision and 28% because of both poor distance and near vision. Psychosocial factors were not statistically significant. CONCLUSIONS Discontinuation of Multifocal Soft Contact Lenses is dependent on the design. Most common cause for discontinuation is poor distance vision. Psychosocial factors do not impact on discontinuation rates.
Collapse
|
14
|
Pérez-Prados R, Piñero DP, Pérez-Cambrodí RJ, Madrid-Costa D. Soft multifocal simultaneous image contact lenses: a review. Clin Exp Optom 2016; 100:107-127. [PMID: 27800638 DOI: 10.1111/cxo.12488] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 04/27/2016] [Accepted: 06/12/2016] [Indexed: 11/30/2022] Open
Abstract
Soft multifocal simultaneous image contact lenses have boomed in recent years due to the growing number of presbyopic patients demanding visual solutions, allowing them to maintain their current standard of living. The concept of 'simultaneous image' is based on blur interpretation and/or blur tolerance of superimposed multiple images on the retina formed by various powers of a contact lens. This is the basis for a specific type of multifocal contact lens developed for the compensation of presbyopia. Manufacturers have released a great variety of soft simultaneous image lens designs to meet different patient needs but their fitting is still unsatisfactory in some cases. Some presbyopes discontinue wearing contact lenses due to some limitations in visual quality and comfort that can be overcome with an appropriate contact lens selection based on a comprehensive pre-fitting evaluation. This paper aims to review the different types of soft multifocal contact lenses that are currently available for presbyopic correction and to define the steps and factors crucial for their fitting, such as pupil, aberrations, accommodation and centring. A discussion about useful tools to achieve a customised fitting leading to a successful outcome, such as the defocus curve, power profile and questionnaires, is performed.
Collapse
Affiliation(s)
- Roque Pérez-Prados
- Centro Óptico Benalúa, Alicante, Spain.,Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain
| | - David P Piñero
- Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain.,Department of Ophthalmology (Oftalmar), Medimar International Hospital, Alicante, Spain.,Foundation for the Visual Quality (FUNCAVIS, Fundación para la Calidad Visual), Alicante, Spain
| | - Rafael J Pérez-Cambrodí
- Department of Ophthalmology (Oftalmar), Medimar International Hospital, Alicante, Spain.,Foundation for the Visual Quality (FUNCAVIS, Fundación para la Calidad Visual), Alicante, Spain
| | - David Madrid-Costa
- Faculty of Optics and Optometry, Complutense University of Madrid, Madrid, Spain
| |
Collapse
|
15
|
Sivardeen A, Laughton D, Wolffsohn JS. Investigating the utility of clinical assessments to predict success with presbyopic contact lens correction. Cont Lens Anterior Eye 2016; 39:322-30. [DOI: 10.1016/j.clae.2016.05.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2015] [Revised: 05/07/2016] [Accepted: 05/09/2016] [Indexed: 10/21/2022]
|
16
|
Cardona G, López S. Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia. JOURNAL OF OPTOMETRY 2016; 9:78-84. [PMID: 26481439 PMCID: PMC4811996 DOI: 10.1016/j.optom.2015.06.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2015] [Revised: 06/12/2015] [Accepted: 06/13/2015] [Indexed: 05/27/2023]
Abstract
PURPOSE To determine working distance, pupil diameter and illumination in real life conditions in a sample of presbyopic participants performing habitual tasks. METHODS A total of 59 presbyopic subjects (aged between 45 and 63 years) with different occupational backgrounds participated in the study. Participants were first interviewed regarding their habitual tasks with the aid of an ad hoc questionnaire, following which in-office photopic and mesopic pupil diameter was determined. Pupil diameter was also evaluated while participants conducted each of the self-reported habitual tasks by taking a photograph, which was later submitted to image analysis. In addition, working distance was determined with a measuring tape and the illumination that reached the pupil during each of the different tasks was measured, in lux, with a light meter. RESULTS The four most common habitual tasks were computer use, reading, sewing and sports. A high intersubject variability was found in pupil diameter, working distance and illumination conditions while conducting the same task. Statistically significant differences were found between the in-office measured photopic and mesopic pupil diameters and those obtained while participants were conducting their habitual tasks in real life conditions (all p<0.001). CONCLUSIONS Potential multifocal contact lens users may present with different ages, different jobs or hobbies and different preferences regarding lighting conditions and working distances. This results in different pupil size, even within the same task. This information may be critical when selecting a particular lens design and add power. Eye care practitioners are therefore advised to assess pupil diameter in real life conditions.
Collapse
Affiliation(s)
- Genís Cardona
- Optics and Optometry Department, Technical University of Catalonia, Spain.
| | - Sílvia López
- Optics and Optometry Department, Technical University of Catalonia, Spain
| |
Collapse
|
17
|
Visual Performance of a Multifocal Contact Lens versus Monovision in Established Presbyopes. Optom Vis Sci 2015; 92:175-82. [PMID: 25525891 DOI: 10.1097/opx.0000000000000476] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To compare subjective and objective visual performance of the Air Optix Aqua Multifocal lens to monovision in a group of subjects requiring a medium level of reading-addition power. METHODS Fifty participants with reading additions between 1.25 and 2.00 diopters (inclusive) were randomized into a prospective, crossover clinical trial. They wore monovision and multifocals for 2 weeks in a randomized order. High- and low-contrast logMAR (logarithm of the minimum angle of resolution) acuity and stereopsis were measured at the beginning and end of each period. During each phase, participants performed specific tasks followed by subjective rating surveys and also completed satisfaction rating surveys on days 3, 7, and 12; all were transferred in real time using BlackBerry smartphones. A general rating survey was completed at the dispensing and 2-week visits. RESULTS Forty-nine participants completed the study (mean age, 52 years). Distance and near high- and low-contrast acuities were significantly better (p < 0.05) with monovision at all visits. High-contrast intermediate acuity was only better (p < 0.05) with multifocals after 2 weeks. Stereopsis was equivalent after 2 weeks, but better (p < 0.05) with multifocals at dispensing. Subjective ratings were generally equivalent between modalities although there was a trend for multifocals to be rated higher for focus changing and driving, whereas monovision tended to be rated higher for near tasks. For both corrections, the satisfaction survey showed no significant change between days 3, 7, and 12, and the general survey showed that comfort was maintained but subjective vision ratings decreased significantly over the 2 weeks. Twenty-five participants (51%) preferred multifocals, 18 (37%) preferred monovision, and the remaining 6 (12%) declared both unacceptable. CONCLUSIONS In this cohort, distance and near acuities were better with monovision, whereas the subjective ratings tended to favor the Air Optix Aqua Multifocal, with the exception of near performance. Preference was statistically similar between both corrections, with a trend toward preferring the multifocal.
Collapse
|
18
|
Fernandes PRB, Neves HIF, Lopes-Ferreira DP, Jorge JMM, González-Meijome JM. Adaptation to multifocal and monovision contact lens correction. Optom Vis Sci 2013; 90:228-235. [PMID: 23376896 DOI: 10.1097/opx.0b013e318282951b] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To compare visual performance with the Biofinity multifocal (MF) contact lens with monovision (MV) with the Biofinity single-vision contact lens. METHODS A crossover study of 20 presbyopic patients was conducted. Patients were randomized first into either an MF or an MV lens for 15 days for each modality, with a washout period between each lens type. Measurements included monocular and binocular high- and low-contrast logarithm of the minimum angle of resolution visual acuity (VA) at distance and near visions, binocular distance contrast sensitivity function, and near stereoacuity. RESULTS At 15 days, patients lost fewer than two letters (half a line of VA) of binocular distance and near VA, with the MF and MV lens under high- and low-contrast conditions (P > 0.05 for both comparisons). No statistically significant differences were seen in binocular VA at near or distance with either lens. However, the monocular distance VA improved significantly in the nondominant eye, with the MF lens by one line over the 15-day period under high-contrast (P = 0.023) and low-contrast (P = 0.035) conditions; this effect was not seen with the MV lens. Contrast sensitivity function was within the normal limits with both lenses. The stereoacuity was significantly (P < 0.01) better with MF than with MV. CONCLUSIONS Multifocal contact lens correction provided satisfactory levels of VA comparable with MV without compromising stereoacuity in this crossover study. The near vision significantly improved in the dominant eye, and the distance vision improved in the nondominant eye from 1 to 15 days with the MF lens, suggesting that patients adapted to the multifocality overtime, whereas this was not true for MV.
Collapse
Affiliation(s)
- Paulo R B Fernandes
- Clinical and Experimental Optometry Research Laboratory (CEORLab), Center of Physics (Optometry), Department of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal.
| | | | | | | | | |
Collapse
|