1
|
Truong CM, Jair YC, Chen HP, Chen WC, Liu YH, Chen PC, Chen PS. Streamlining regular liquid chromatography with MALDI-TOF MS and NMR spectroscopy using automatic full-contact splitless spotting interface and flash-tap fractioning collection. Anal Chim Acta 2024; 1298:342401. [PMID: 38462340 DOI: 10.1016/j.aca.2024.342401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 02/18/2024] [Accepted: 02/20/2024] [Indexed: 03/12/2024]
Abstract
BACKGROUND High-resolution matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) and nuclear magnetic resonance (NMR) spectroscopy are powerful tools to identify unknown psychoactive substances. However, in complex matrices, trace levels of unknown substances usually require additional fractionation and concentration. Specialized liquid chromatography systems are necessary for both techniques. The small flow rate of nano LC, typically paired with MALDI-TOF MS, often results in prolonged fractionation times. Conversely, the larger flow rate of semi-preparative LC, used for NMR analysis, can be time-consuming and labor-intensive when concentrating samples. To address these issues, we developed an integrated automatic system that integrated to regular LC. RESULT Automatic spot collector (ASC) and automatic fraction collector (AFC) were present in this study. The ASC utilized in-line matrix mixing, full-contact spotting and real time heating (50 °C), achieving great capacity of 5 μL droplet on MALDI plate, high recovery (76-116%) and rapid evaporation in 2 min. The analytes were concentrated 4-8 times, forming even crystallization, reaching the detection limit at the concentration of 50 μg L-1 for 12 psychoactive substances in urine. The AFC utilizes flexible tubing which flash-tapped the microtube's upper rim (3 mm depth) instead of reaching the bottom. This method prevents sample loss and minimizes the robotic arm's movement, providing a high fractionating speed at 6 s 12 psychoactive compounds were fractionated in a single round analysis (recovery: 81%-114%). Methamphetamine and nitrazepam obtained from drug-laced coffee samples were successful analyzed with photodiode array (PDA) after one AFC round and NMR after five rounds. SIGNIFICANCE The ASC device employed real-time heating, in-line matrix mixing, and full-contact spotting to facilitate the samples spotting onto the MALDI target plate, thereby enhancing detection sensitivity in low-concentration and complex samples. The AFC device utilized the novel flash-tapping method to achieve rapid fractionation and high recovery rate. These devices were assembled using commercially available components, making them affordable (400 USD) for most laboratories while still meeting the required performance for advanced commercialized systems.
Collapse
Affiliation(s)
- Chi-Minh Truong
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Yung-Cheng Jair
- Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan
| | - Hong-Po Chen
- Department of Chemistry, National Taiwan Normal University, Taipei, Taiwan
| | - Wei-Chih Chen
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan
| | - Yi-Hsin Liu
- Department of Chemistry, National Taiwan Normal University, Taipei, Taiwan
| | - Pin-Chuan Chen
- Department of Mechanical Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan.
| | - Pai-Shan Chen
- Institute of Toxicology, College of Medicine, National Taiwan University, Taipei, Taiwan.
| |
Collapse
|
2
|
Some Applications of Liquid Chromatography-Mass Spectrometry in the Biomedical Field. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/bs.coac.2017.09.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
|
3
|
Uliyanchenko E. Applications of Hyphenated Liquid Chromatography Techniques for Polymer Analysis. Chromatographia 2017. [DOI: 10.1007/s10337-016-3193-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
4
|
|
5
|
Paoletti AC, Zybailov B, Washburn MP. Principles and applications of Multidimensional Protein Identification Technology. Expert Rev Proteomics 2014; 1:275-82. [PMID: 15966824 DOI: 10.1586/14789450.1.3.275] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Multidimensional chromatography coupled to tandem mass spectrometry is an emerging technique for the analysis of proteomes and is rapidly being implemented by many researchers for proteomic analysis. In this technology profile, a particular proteomic approach known as multidimensional protein identification technology (MudPIT) is discussed. In MudPIT, a biphasic microcapillary column is packed with high-performance liquid chromatography grade reversed phase and strong cation exchange packing materials, loaded with a complex peptide mixture and placed in line with quaternary high-performance liquid chromatography and a tandem mass spectrometer. MudPIT has the capability to analyze highly complex proteomic mixtures such as whole proteomes, organelles and protein complexes.
Collapse
Affiliation(s)
- Andrew C Paoletti
- Stowers Institute for Medical Research, 1000 E. 50th St., Kansas City, MO 64110, USA.
| | | | | |
Collapse
|
6
|
Pereira F, Niu X, deMello AJ. A nano LC-MALDI mass spectrometry droplet interface for the analysis of complex protein samples. PLoS One 2013; 8:e63087. [PMID: 23671657 PMCID: PMC3650041 DOI: 10.1371/journal.pone.0063087] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2012] [Accepted: 04/01/2013] [Indexed: 11/30/2022] Open
Abstract
The integration of matrix-assisted laser desorption ionization (MALDI) mass spectrometry with an upstream analytical separations (such as liquid chromatography and electrophoresis) has opened up new opportunities for the automated investigation of complex protein and peptide mixtures. The ability to efficiently analyze complex proteomic mixtures in this manner is primarily determined by the ability to preserve spatial discrimination of sample components as they leave the separation column. Current interfacing methods are problematic in this respect since minimum fraction volumes are limited to several microliters. Herein we show for the first time an LC-MALDI interface based on the formation, processing and destruction of a segmented flow. The interface consists of a droplet-generator to fractionate LC effluent into nL-volume droplets and a deposition probe that transfers the sample (and MALDI matrix) onto a conventional MALDI-MS target. The efficacy of the method is demonstrated through the analysis of Trypsin digests of both BSA and Cytochrome C, with a 50% enhancement in analytical performance when compared to conventional interface technology.
Collapse
Affiliation(s)
- Fiona Pereira
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Zurich, Switzerland
| | - Xize Niu
- Engineering and the Environment, and Institute for Life Sciences, University of Southampton, Highfield, Southampton, England
| | - Andrew J. deMello
- Institute for Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich, Zurich, Switzerland
- * E-mail:
| |
Collapse
|
7
|
Zhang Z, Jiang S, Li L. Semi-automated liquid chromatography-mass spectrometric imaging platform for enhanced detection and improved data analysis of complex peptides. J Chromatogr A 2013; 1293:44-50. [PMID: 23623366 DOI: 10.1016/j.chroma.2013.03.042] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2012] [Revised: 03/16/2013] [Accepted: 03/18/2013] [Indexed: 11/18/2022]
Abstract
A semi-automated analytical platform featuring the coupling of monolithic reversed-phase liquid chromatography (RPLC) to matrix-assisted laser desorption/ionization mass spectrometric imaging (MALDI MSI) has been developed and evaluated. This is the first time that LC separation is readily coupled to MS imaging detection for the analysis of complex peptide mixtures both qualitatively and quantitatively. Methacrylate-based monolithic column with C12 functional groups is fabricated for fast RPLC separation. The LC flow and matrix flow are collected on a commercially available MALDI plate which is mechanically controlled and analyzed with MALDI MSI subsequently. Both tryptic peptides digested from bovine serum albumin (BSA) and endogenous neuropeptides extracted from the blue crab Callinectes sapidus are analyzed with this novel LC-MSI platform. Compared with regular offline LC fractionation coupled with MALDI MS detection, LC-MSI exhibits significantly increased MS signal intensity due to retaining of temporal resolution from separation dimension via continuous sampling, which results in increased number of peptides detected and accurate quantitation. In addition, imaging signals enable improved data analysis based on either mass-to-charge ratio or retention time, which is extremely beneficial for the analysis of complex analytes. These findings have demonstrated the potential of employing LC-MSI platform for enhanced proteomics and peptidomics studies.
Collapse
Affiliation(s)
- Zichuan Zhang
- School of Pharmacy, University of Wisconsin, 777 Highland Avenue, Madison, WI 53705, USA
| | | | | |
Collapse
|
8
|
Peš O, Preisler J. Off-line coupling of microcolumn separations to desorption mass spectrometry. J Chromatogr A 2010; 1217:3966-77. [DOI: 10.1016/j.chroma.2010.02.058] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2009] [Revised: 02/22/2010] [Accepted: 02/24/2010] [Indexed: 01/13/2023]
|
9
|
Abstract
Liquid chromatography (LC) can be combined with matrix-assisted laser-desorption ionization (MALDI) mass-spectrometry (MS) by using automated off-line fraction collection of eluates onto a MALDI plate. Commercial tandem MS systems are available for generating product ion spectra of MALDI-produced peptide ions. The MALDI MS/MS spectra can be searched against a proteome database for protein identification. In this chapter, a protocol of sequential solubilization and digestion of membrane proteins involving methanol- and SDS-assisted trypsin digestion and microwave-assisted acid hydrolysis is presented. The process of LC eluate deposition onto a MALDI plate along with practical considerations for achieving optimal performance of eluate deposition is described. Issues related to MALDI MS and MS/MS spectral acquisition are discussed. Database searching and manual inspection of MS/MS spectra of singly charged MALDI-produced peptide ions for positive protein identification are also addressed.
Collapse
|
10
|
Zhang N, Shaw ARE, Li N, Chen R, Mak A, Hu X, Young N, Wishart D, Li L. Liquid chromatography electrospray ionization and matrix-assisted laser desorption ionization tandem mass spectrometry for the analysis of lipid raft proteome of monocytes. Anal Chim Acta 2008; 627:82-90. [PMID: 18790130 DOI: 10.1016/j.aca.2008.05.058] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2008] [Revised: 05/22/2008] [Accepted: 05/24/2008] [Indexed: 10/22/2022]
Abstract
Lipid rafts are dynamic assemblies of cholesterol and glycolipid that form detergent-insoluble microdomains within membrane lipid bilayers. Because rafts can be separated by flotation on sucrose gradients, interrogation by mass spectrometry (MS) provides a valuable new insight into lipid raft function. Here we combine liquid chromatography (LC) electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) MS/MS to corroborate and extend our previous description of lipid raft proteomes derived from the monocytic cell line THP-1. Interestingly, LC-ESI and MALDI MS/MS identify largely non-overlapping, and therefore, potentially complementary protein populations. Using the combined approach, we detected 277 proteins compared to 52 proteins obtained with the original gel-based MALDI MS. We confirmed the presence of 47 of the original 52 proteins demonstrating the consistency of the lipid raft preparations. We demonstrated by immunoblotting that Rac 1 and Rac 2, two of the 52 proteins we failed to confirm, were indeed absent from the lipid raft fractions. The majority of new proteins were cytoskeletal proteins and their regulators, proteins implicated in membrane fusion and vesicular trafficking or signaling molecules. Our results therefore, confirm and extend previous evidence indicating lipid rafts of monocytic cells are specialized for cytoskeletal assembly and vesicle trafficking. Of particular interest, we detected SNAP-23, basigin, Glut-4 and pantophysin in lipid rafts. Since these proteins are implicated in both vesicular trafficking and gamete fusion, lipid rafts may play a common role in these processes. It is evident that the combination of LC-ESI and LC-MALDI MS/MS increases the proteome coverage which allows better understanding of the lipid raft function.
Collapse
Affiliation(s)
- Nan Zhang
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Young JB, Li L. Impulse-Driven Heated-Droplet Deposition Interface for Capillary and Microbore LC−MALDI MS and MS/MS. Anal Chem 2007; 79:5927-34. [PMID: 17605467 DOI: 10.1021/ac070383k] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
An automated off-line liquid chromatography-matrix-assisted laser desorption ionization (LC-MALDI) interface capable of coupling both capillary and microbore LC separations with MALDI mass spectrometry (MS) and tandem mass spectrometry (MS/MS) has been developed. The interface is a combination of two concepts: analyte concentration from heated hanging droplets and impulse-driven droplet deposition of LC fractions onto a MALDI sample plate. At room temperature the interface allows the coupling of capillary LC separations (i.e., flow rate of <5 microL/min) with MALDI MS. With heating, it can be used to combine microbore LC operated at a relatively high flow rate of up to 50 microL/min with MALDI MS. The collected fractions can be analyzed by MALDI MS and MS/MS instruments, such as time-of-flight (TOF) and quadrupole-TOF MS. Performance of the interface was examined using several peptide and protein standards. It was shown that, using MALDI-TOF MS, [GLU1]-fibrinopeptide B could be detected with a total injection amount of 5 fmol to microbore LC. Chromatographic performance was also monitored. A peak width of 12 s at half-height for [GLU1]-fibrinopeptide B showed no evidence of band broadening due to the interface. The ability of the interface to mitigate ion suppression was studied using a mixture of 100 fmol of [GLU1]-fibrinopeptide B and 10 pmol of cytochrome c tryptic digest. Although fully suppressed under direct MALDI conditions, LC-MALDI analysis was able to detect the 100 fmol peptide with 10 s fraction collection. Finally, the ability to inject relatively large sample amounts to improve detectability of low-abundance peptides was illustrated in the analysis of phosphopeptides from alpha-casein tryptic digests. A digest loaded on column to 2.4 microg and analyzed by LC-MALDI MS/MS resulted in 82% sequence coverage and detection of all nine phosphoserine residues. It is concluded that, being able to handle both high- and low-flow LC separations, the impulse-driven heated-droplet interface provides the flexibility to carry out MALDI analysis of peptides and proteins depending on the information sought after, analysis speed, and sample size.
Collapse
Affiliation(s)
- J Bryce Young
- Department of Chemistry, University of Alberta, Edmonton, Alberta T6G 2G2, Canada
| | | |
Collapse
|
12
|
Fournier ML, Gilmore JM, Martin-Brown SA, Washburn MP. Multidimensional Separations-Based Shotgun Proteomics. Chem Rev 2007; 107:3654-86. [PMID: 17649983 DOI: 10.1021/cr068279a] [Citation(s) in RCA: 171] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
13
|
Hu L, Ye M, Jiang X, Feng S, Zou H. Advances in hyphenated analytical techniques for shotgun proteome and peptidome analysis--a review. Anal Chim Acta 2007; 598:193-204. [PMID: 17719892 DOI: 10.1016/j.aca.2007.07.046] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2007] [Revised: 07/17/2007] [Accepted: 07/18/2007] [Indexed: 01/30/2023]
Abstract
Proteomics is defined as the analysis of part or all of the protein components of a complex biological system (a cell, organ or tissue) at a given moment. Due to the huge number of proteins encoded by the genome, novel analytical techniques must be developed to meet the need of large scale analysis. This has led to the hyphenation of multiple techniques to achieve this object. Here current status of the hyphenated analytical techniques of one-dimensional and multidimensional liquid chromatography-mass spectrometry for shotgun proteomic analysis is reviewed, and on-line techniques for automated sample preparation and injection are also covered. In addition, the hyphenated techniques for peptidome analysis are also covered.
Collapse
Affiliation(s)
- Lianghai Hu
- National Chromatographic R&A Center, Dalian Institute of Chemical Physics, Graduate School of the Chinese Academy of Sciences, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian 116023, China
| | | | | | | | | |
Collapse
|
14
|
Bodzon-Kulakowska A, Bierczynska-Krzysik A, Dylag T, Drabik A, Suder P, Noga M, Jarzebinska J, Silberring J. Methods for samples preparation in proteomic research. J Chromatogr B Analyt Technol Biomed Life Sci 2007; 849:1-31. [PMID: 17113834 DOI: 10.1016/j.jchromb.2006.10.040] [Citation(s) in RCA: 176] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2006] [Accepted: 10/23/2006] [Indexed: 01/04/2023]
Abstract
Sample preparation is one of the most crucial processes in proteomics research. The results of the experiment depend on the condition of the starting material. Therefore, the proper experimental model and careful sample preparation is vital to obtain significant and trustworthy results, particularly in comparative proteomics, where we are usually looking for minor differences between experimental-, and control samples. In this review we discuss problems associated with general strategies of samples preparation, and experimental demands for these processes.
Collapse
Affiliation(s)
- Anna Bodzon-Kulakowska
- Department of Neurobiochemistry, Faculty of Chemistry, Jagiellonian University, Ingardena St. 3, 30-060 Krakow, Poland
| | | | | | | | | | | | | | | |
Collapse
|
15
|
Lee H. Pharmaceutical Applications of Liquid Chromatography Coupled with Mass Spectrometry (LC/MS). J LIQ CHROMATOGR R T 2007. [DOI: 10.1081/jlc-200053022] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Heewon Lee
- a Boehringer Ingelheim Pharmaceuticals, Inc. , Ridgefield, Connecticut, USA
| |
Collapse
|
16
|
Ji C, Zhang N, Damaraju S, Damaraju VL, Carpenter P, Cass CE, Li L. A study of reproducibility of guanidination-dimethylation labeling and liquid chromatography matrix-assisted laser desorption ionization mass spectrometry for relative proteome quantification. Anal Chim Acta 2007; 585:219-26. [PMID: 17386668 DOI: 10.1016/j.aca.2006.12.054] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2006] [Revised: 12/11/2006] [Accepted: 12/20/2006] [Indexed: 11/25/2022]
Abstract
The combination of dimethylation after guanidination (2MEGA) isotope labeling with microbore liquid chromatography (LC)-matrix-assisted laser desorption ionization (MALDI) MS and MS/MS [C. Ji, N. Guo, L. Li, J. Proteome Res. 4 (2005) 2099] has been reported as a promising strategy for abundance ratio-dependent quantitative proteome analysis. A critical step in using this integrated strategy is to set up the abundance ratio threshold of peptide pairs, above which the peptide pairs are used for quantifying and identifying the protein that is considered to be differentially expressed between two different samples. The threshold is determined by technical variation (i.e., the overall abundance ratio variation caused by the experimental process including sample workup, MS analysis and data processing) as well as biological variation (i.e., the abundance ratio variation caused by the biological process including cell growth), which can be defined and assessed by a coefficient of variation (CV). We have designed experiments and measured three different levels of variations, starting with the same membrane protein preparation, the same batch of cells and three batches of cells from the same cell line grown under the same conditions, respectively. It is shown that technical variation from the experimental processes involved in 2MEGA labeling LC-MALDI MS has a CV of <15%. In addition, the measured biological variation from cell growth was much smaller than the measured technical variation. From the studies of the occurrence rate of outliers in the distribution of the abundance ratio data within a comparative dataset of peptide pairs, it is concluded that, to compare the proteome changes between two sets of cultured cells without the use of replicate experiments, a relative abundance ratio of greater than 2X or less than 0.5X (X is the average abundance ratio of the dataset) on peptide pairs can be used as a stringent threshold to quantify and identify differentially expressed proteins with high confidence.
Collapse
Affiliation(s)
- Chengjie Ji
- Department of Chemistry, University of Alberta, Cross Cancer Institute, Edmonton, Alberta, Canada T6G 2G2
| | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
Liquid chromatography-matrix-assisted laser desorption/ionization mass spectrometry represents a sensitive, hyphenated MS- and MS/MS-technique with a broad range of applications in all areas ofproteome analysis. Whereas a number of interface types have been developed for coupling MALDI MS and liquid chromatography, in this chapter selected on-line and off-line types and techniques will be discussed with respect to their individual properties and performance. The technique is especially attractive in off-line mode where LC-separation and MS analyses are decoupled and each step can be performed at its individual optimum. Different speed of chromatographic separation and achievement of S/N criteria in MS or MS/MS mode can be optimized independently by individual adjustment of specific operating parameters. This flexibility makes LC-MALDI MS attractive for the analysis of peptide mixtures from low to medium complexity. Using sequential MS analysis of parallel LC runs (multiplexing), even highly complex samples can be handled. Quantitation at the MS and MS/MS level can be accomplished by a variety of labeling techniques, where the predominant formation of singly charged ions in MALDI alleviates the assignment of isotopomers. After discussing the level of complementarity between LC-MALDI and LC-ESI MS, selected applications of LC-MALDI MS are presented. Examples of membrane protein analysis applying 1D SDS PAGE are discussed in detail as well as applications in protein interaction analysis. These application examples clearly show that in all respects LC-MALDI MS and MS/MS are flexible and sensitive techniques which can be adapted to a wide range of different workflows.
Collapse
|
18
|
Martic S, Brennan JD, Brook MA, Ackloo S, Nagy N. Towards the development of a covalently tethered MALDI system — A study of allyl-modified MALDI matrixes. CAN J CHEM 2007. [DOI: 10.1139/v06-185] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
An emerging application of matrix-assisted laser desorption ionization (MALDI) mass spectrometry is the analysis of low molecular weight (LMW) compounds, often via coupled liquid chromatography — MALDI-MS methods. However, in many cases, the low molecular weight region of MALDI mass spectra is obscured by the presence of signals originating from the matrix, suggesting that the development of tethered MALDI matrixes may be required to optimize MS performance for such compounds. To gain insight into potential sites for covalent attachment of MALDI matrixes, we have systematically investigated the role played by a variety of functional group motifs in determining matrix efficiency for three common MALDI matrixes, as judged both by total signal intensity and background noise from matrix decomposition for a set of LMW compounds. A series of allyl derivatives of standard matrixes was prepared, and the efficiency of these materials in the MALDI experiment was measured. All modifications of established matrixes, e.g., 2,5-dihydroxybenzoic acid (DHB), α-cyano-4-hydroxycinnamic acid (CHCA), and caffeic acid (CA), or close analogues led to decreased absolute signal intensity and signal-to-background levels. Improved performance was generally observed with (i) the presence of a phenolic group (carboxylic acids were less effective) (ii) crystalline derivatives, and (iii) compounds that had high extinction coefficients at wavelengths near to that of the exciting laser (337 nm). The most interesting derivatives were the O-allyl ether (15) and N-allyl amide (16) of caffeic acid. These compounds did not facilitate signals from all four analytes tested. However, the observed spectra contained fewer signals from the matrix than from the parent compound CA. These compounds demonstrate that functionalization of MALDI matrixes, ultimately leading to tethered matrixes, is possible without jeopardizing signal intensity.Key words: MALDI, protected matrix, phenol, caffeic acid, allyl ether.
Collapse
|
19
|
Gebremedhin M, Zhong H, Wang S, Weinfeld M, Li L. Benefit of microwave-assisted acid hydrolysis of proteins for mass spectrometric profiling of the human heart tissue proteome. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:2779-83. [PMID: 17654473 DOI: 10.1002/rcm.3125] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
|
20
|
McComb ME, Perlman DH, Huang H, Costello CE. Evaluation of an on-target sample preparation system for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in conjunction with normal-flow peptide high-performance liquid chromatography for peptide mass fingerprint analyses. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2007; 21:44-58. [PMID: 17133622 DOI: 10.1002/rcm.2805] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Large-scale mass spectrometry (MS)-based proteomic analyses require high-throughput sample preparation techniques due to the increasing numbers of samples that make up a typical proteomics experiment. Moreover, extensive sample pre-treatment steps are necessary prior to MS acquisition for even the most rapid and robust MS-based proteomics methodology, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS followed by peptide mass fingerprinting (PMF) analysis. These include sample purification and fractionation, removal of digestion buffers or solvents, and spotting of sample with matrix onto the MALDI target. These multiple steps of time-consuming sample handling can result in high overall analysis costs and the likelihood of sample contamination and loss. In order to overcome some of these limitations in sample processing, we have investigated the use of a novel, simple, inexpensive 96-well elastomeric array that affixes to a MALDI target to create an on-target 96-well plate that accommodates a high solution volume (ca. 200 microL), thereby enabling the on-target processing of samples for MALDI-TOFMS. We explored several factors that influence MALDI sample preparation: type of matrix, solution volume, solution organic composition, solution drying rates and matrix/analyte co-crystallization methods. We also investigated the use of the 96-well elastomeric device for coupling MALDI-TOFMS analysis directly to high flow rate (1 mL/min) reversed-phase (rp)-HPLC. By developing an optimized, robust sample preparation protocol, we were able to obtain mass spectra with a high signal-to-noise ratio from peptide standards present at the 50-fmol level in large starting volumes of solution. PMF analyses were possible from 1-pmol and 500-fmol protein-digest standards. Coupling the device to high-flow HPLC (750 microL/min) yielded a robust and semi-automated means to obtain enhanced MALDI-TOFMS data at 500 ng of protein digest. These methodologies developed for this simple, on-target, elastomeric device show promise for streamlining the sample preparation process from HPLC to MALDI-MS.
Collapse
Affiliation(s)
- Mark E McComb
- Cardiovascular Proteomics Center, Boston University School of Medicine, Boston, MA 02118-2646, USA.
| | | | | | | |
Collapse
|
21
|
Yoo C, Zhao J, Pal M, Hersberger K, Huber CG, Simeone DM, Beer DG, Lubman DM. Automated integration of monolith-based protein separation with on-plate digestion for mass spectrometric analysis of esophageal adenocarcinoma human epithelial samples. Electrophoresis 2006; 27:3643-51. [PMID: 16927349 DOI: 10.1002/elps.200600117] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A unique approach of automating the integration of monolithic capillary HPLC-based protein separation and on-plate digestion for subsequent MALDI-MS analysis has been developed. All liquid-handling procedures were performed using a robotic module. This automated high-throughput method minimizes the amount of time and extensive labor required for traditional in-solution digestion followed by exhaustive sample cleanup and analysis. Also, precise positioning of the droplet from the capillary HPLC separation onto the MALDI plate allows for preconcentration effects of analytes for improved sensitivity. Proteins from primary esophageal Barrett's adenocarcinoma tissue were prefractionated by chromatofocusing and analyzed successfully by this automated configuration, obtaining rapid protein identifications through PMF and sequencing analyses with high sequence coverage. Additionally, intact protein molecular weight values were obtained as a means to further confirm protein identification and also to identify potential sequence modifications of proteins. This simple and rapid method is a highly versatile and robust approach for the analysis of complex proteomes.
Collapse
Affiliation(s)
- Chul Yoo
- Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA
| | | | | | | | | | | | | | | |
Collapse
|
22
|
Corr JJ, Kovarik P, Schneider BB, Hendrikse J, Loboda A, Covey TR. Design considerations for high speed quantitative mass spectrometry with MALDI ionization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2006; 17:1129-1141. [PMID: 16750388 DOI: 10.1016/j.jasms.2006.04.026] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2006] [Revised: 04/18/2006] [Accepted: 04/20/2006] [Indexed: 05/10/2023]
Abstract
A MALDI ion source on a triple quadrupole mass spectrometer constructed for the purpose of obtaining high speed quantitative measurements on drugs and other low molecular weight compounds is described. Particular attention is given to the ion generation and transport phenomena that affect analysis speed, throughput, and practical instrument robustness. In this regard parameters that affect desorption speed, beam spreading, ion flight times, sensitivity, signal-to-noise, ion fragmentation, sample carry-over, and instrument contamination are examined and experimental results are provided. MALDI and electrospray sensitivity is compared, to provide a practical frame of reference.
Collapse
Affiliation(s)
- Jay J Corr
- MDS SCIEX, 71 Four Valley Drive, L4K 4V8, Concord, ON, Canada
| | - Peter Kovarik
- MDS SCIEX, 71 Four Valley Drive, L4K 4V8, Concord, ON, Canada
| | | | - Jan Hendrikse
- MDS SCIEX, 71 Four Valley Drive, L4K 4V8, Concord, ON, Canada
| | | | - Thomas R Covey
- MDS SCIEX, 71 Four Valley Drive, L4K 4V8, Concord, ON, Canada.
| |
Collapse
|
23
|
|
24
|
Young JB, Li L. An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2006; 17:325-34. [PMID: 16443366 DOI: 10.1016/j.jasms.2005.11.018] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Revised: 11/18/2005] [Accepted: 11/28/2005] [Indexed: 05/06/2023]
Abstract
A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.
Collapse
Affiliation(s)
- J Bryce Young
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | | |
Collapse
|
25
|
Ro KW, Liu J, Knapp DR. Plastic microchip liquid chromatography-matrix-assisted laser desorption/ionization mass spectrometry using monolithic columns. J Chromatogr A 2006; 1111:40-7. [PMID: 16480733 DOI: 10.1016/j.chroma.2006.01.105] [Citation(s) in RCA: 64] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2005] [Revised: 01/10/2006] [Accepted: 01/24/2006] [Indexed: 10/25/2022]
Abstract
A prototype array of monolithic liquid chromatography (LC) columns was prepared in a plastic microfluidic device for the off-line interface with matrix assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The microfluidic channels were fabricated on a cyclic olefin copolymer (COC) plate by hot embossing. An array of methacrylate monolithic columns was prepared in the microfluidic channels by UV-initiated polymerization. The deposition system employed a pulsed electric field to transfer the effluents from multiple columns directly onto MALDI targets with a non-contact deposition method reported by Ericson et al. [C. Ericson, Q.T. Phung, D.M. Horn, E.C. Peters, J.R. Fitchett, S.B. Ficarro, A.R. Salmon, L.M. Brill, A. Brock, Anal. Chem. 75 (2003) 2309]. To characterize the off-line interface of the multiple-channel microchip LC and the MALDI-MS for the analysis of peptide mixtures, the separation efficiency and reproducibility tests in each column were carried out by separating a peptide mixture from tryptic digested proteins and depositing the multiple effluents simultaneously on the MALDI target plate. Using a MALDI-TOF mass spectrometer with a mass accuracy of +/-1 Da for peptide assignments of digested bovine serum albumin (BSA), amino acid sequence coverage of around 59% was obtained for the microchip LC-MALDI-MS compared to 23% obtained by the MALDI-MS method without LC separation. In sensitivity tests for the detection of low abundance proteins in the presence of high concentration protein mixtures, as low as 10 fmol/mul (S/N = 10) of a spiked peptide in 1 microg of digested BSA could be detected. In the analysis of a mixture of three digested proteins (BSA, myoglobin, and cytochrome c), more than twice the amino acid sequence coverage was obtained for the microchip LC-MALDI-MS compared to MALDI-MS alone.
Collapse
Affiliation(s)
- Kyung Won Ro
- Department of Cell and Molecular Pharmacology and Experimental Therapeutics, Medical University of South Carolina, Charleston, 29425, USA
| | | | | |
Collapse
|
26
|
Creaser CS, Green PS, Kilby PM, Ratcliffe L. Capillary liquid chromatography/atmospheric-pressure matrix-assisted laser desorption/ionisation ion trap mass spectrometry: a comparison with liquid chromatography/matrix-assisted laser desorption/ionisation time-of-flight and liquid chromatography/electrospray ionisation quadrupole time-of-flight for the identification of tryptic peptides. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:829-36. [PMID: 16470569 DOI: 10.1002/rcm.2376] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The atmospheric-pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI-QIT) analysis of tryptic peptides is reported following capillary liquid chromatographic (LC) separation and direct analysis of a protein digest. Peptide fragments were identified by peptide mass fingerprinting from mass spectrometric data and sequence analysis obtained by tandem mass spectrometry of the principal mass spectral peaks using a data-dependent scanning protocol. These data were compared with those from mass spectrometric analysis using capillary LC/MALDI-time-of-flight (TOF) and capillary LC/electrospray ionisation (ESI)-quadrupole TOF. For all three configurations the resulting data were searched against the MSDB database, using MASCOT and the sequence coverage compared for each technique. Complementary data were obtained using the three techniques.
Collapse
Affiliation(s)
- Colin S Creaser
- School of Biomedical and Natural Sciences, Nottingham Trent University, Nottingham NG11 8NS, UK.
| | | | | | | |
Collapse
|
27
|
Limited proteolysis combined with isotope labeling and quantitative LC-MALDI MS for monitoring protein conformational changes: a study on calcium-binding sites of cardiac Troponin C. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2004.04.017] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
28
|
Zhong H, Marcus SL, Li L. Microwave-assisted acid hydrolysis of proteins combined with liquid chromatography MALDI MS/MS for protein identification. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2005; 16:471-81. [PMID: 15792716 DOI: 10.1016/j.jasms.2004.12.017] [Citation(s) in RCA: 118] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2004] [Revised: 12/23/2004] [Accepted: 12/23/2004] [Indexed: 05/13/2023]
Abstract
Simple and efficient digestion of proteins, particularly hydrophobic membrane proteins, is of significance for comprehensive proteome analysis using the bottom-up approach. We report a microwave-assisted acid hydrolysis (MAAH) method for rapid protein degradation for peptide mass mapping and tandem mass spectrometric analysis of peptides for protein identification. It uses 25% trifluoroacetic acid (TFA) aqueous solution to dissolve or suspend proteins, followed by microwave irradiation for 10 min. This detergent-free method generates peptide mixtures that can be directly analyzed by liquid chromatography (LC) matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS) without the need of extensive sample cleanup. LC-MALDI MS/MS analysis of the hydrolysate from 5 microg of a model transmembrane protein, bacteriorhodopsin, resulted in almost complete sequence coverage by the peptides detected, including the identification of two posttranslational modification sites. Cleavage of peptide bonds inside all seven transmembrane domains took place, generating peptides of sizes amenable to MS/MS to determine possible sequence errors or modifications within these domains. Cleavage specificity, such as glycine residue cleavage, was observed. Terminal peptides were found to be present in relatively high abundance in the hydrolysate, particularly when low concentrations of proteins were used for MAAH. It was shown that these peptides could still be detected from MAAH of bacteriorhodopsin at a protein concentration of 1 ng/microl or 37 fmol/microl. To evaluate the general applicability of this method, it was applied to identify proteins from a membrane protein enriched fraction of cell lysates of human breast cancer cell line MCF7. With one-dimensional LC-MALDI MS/MS, a total of 119 proteins, including 41 membrane-associated or membrane proteins containing one to 12 transmembrane domains, were identified by MS/MS database searching based on matches of at least two peptides to a protein.
Collapse
Affiliation(s)
- Hongying Zhong
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | | | | |
Collapse
|
29
|
Zhang X, Narcisse DA, Murray KK. On-line single droplet deposition for MALDI mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2004; 15:1471-1477. [PMID: 15465360 DOI: 10.1016/j.jasms.2004.06.016] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2004] [Revised: 06/28/2004] [Accepted: 06/29/2004] [Indexed: 05/09/2023]
Abstract
A single droplet generator was coupled with a rotating ball inlet matrix-assisted laser desorption/ionization (MALDI) time of flight (TOF) mass spectrometer. Single droplets with 100 picoliter volume were ejected by a piezoelectric-actuated droplet generator and deposited onto a matrix-coated rotating stainless steel ball at atmospheric pressure. The single droplet deposit was transported to the vacuum side of the instrument where ionization was accomplished using a UV pulsed laser. Using this on-line interface, it was possible to obtain protonated molecule signal from as little as 10 fmol analyte.
Collapse
Affiliation(s)
- Xia Zhang
- Department of Chemistry, Louisiana State University, 232 Choppin Hall, 70803, Baton Rouge, LA, USA
| | - Damien A Narcisse
- Department of Chemistry, Louisiana State University, 232 Choppin Hall, 70803, Baton Rouge, LA, USA
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, 232 Choppin Hall, 70803, Baton Rouge, LA, USA.
| |
Collapse
|
30
|
Bogan MJ, Agnes GR. Preliminary investigation of electrodynamic charged droplet processing to couple capillary liquid chromatography with matrix-assisted laser desorption/ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2004; 18:2673-2681. [PMID: 15476188 DOI: 10.1002/rcm.1670] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Charged droplet processing methodology, that utilizes electrodynamic levitation technology to control the trajectories of picoliter volume charged droplets and deliver them to a target plate at atmospheric pressure, has been developed. Termed wall-less sample preparation (WaSP), this methodology offers several features that could prove beneficial to the preparation of sample spots from separation column effluents for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) analysis. These features include solute pre-concentration factors of 10(1) to 10(3) due to volatile solvent evaporation prior to droplet deposition onto the target plate, high spatial accuracy of the deposition position of each processed droplet (+/-5 microm), and the ability to prepare sample spots as small as 20 microm in diameter from a single droplet. Here a new mode of operation of this methodology is described and used as an offline post-column pre-concentrating interface between capillary liquid chromatography (capLC) and a target plate for offline MALDI-MS. Using a fraction from the capLC separation of peptides produced by the proteolytic digestion of the protein cytidine 5'-triphosphate:phosphocholine cytidylyltransferase, MALDI sample spots were prepared using the dried-droplet method, direct piezoelectric droplet dispensing, and the processing of piezo-dispensed droplets by WaSP. The sample spot morphology was investigated using light microscopy, and peptide ion abundances produced by MALDI were measured using time-of-flight (TOF) MS. The advantages of developing an online capLC/WaSP interface with MALDI-MS in the future are discussed along with some of the challenges that may be encountered in such an endeavor.
Collapse
Affiliation(s)
- Michael J Bogan
- Department of Chemistry, Simon Fraser University, Burnaby, BC, V5A 1S6, Canada
| | | |
Collapse
|