1
|
Investigation of pH-dependent extraction methods for PFAS in (fluoropolymer-based) consumer products: A comparative study between targeted and sum parameter analysis. CHEMOSPHERE 2024; 351:141200. [PMID: 38228192 DOI: 10.1016/j.chemosphere.2024.141200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Revised: 01/10/2024] [Accepted: 01/11/2024] [Indexed: 01/18/2024]
Abstract
Here, we report a comparative study of different sum parameter analysis methods for the extraction of per- and polyfluoroalkyl substances (PFAS) from manufactured consumer products, which can be measured by combustion ion chromatography (CIC). Therefore, a hydrolysis-based extraction method was further developed, which accounts for the addition of hydrolyzable covalently bound polyfluoroalkylated side-chain polymers (SFPs) to the extractable organic fluorine portion of the mass balance proposed as "hydrolyzable organically bound fluorine" (HOF). To test this hypothesis, the method was applied to 39 different consumer products containing fluoropolymers or monomeric PFAS taken from four different categories: outdoor textiles, paper packaging, carpeting, and permanent baking sheets. We also evaluated the method's efficiency by extracting four synthesized fluorotelomer polyacrylate reference compounds. The total fluorine (TF) and extractable organically bound fluorine (EOF) values were measured through CIC using established protocols. The TF values ranged from sub-ppb to %-levels, depending on the compound class. All samples showed results for hydrolyzed organofluorine (HOF) between 0.03 and 76.3 μg/g, while most EOF values were lower (
Collapse
|
2
|
Identification and quantification of fluorinated polymers in consumer products by combustion ion chromatography and pyrolysis-gas chromatography-mass spectrometry. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2024; 26:82-93. [PMID: 38099738 DOI: 10.1039/d3em00438d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/25/2024]
Abstract
Total fluorine was determined in 45 consumer product samples from the Swedish market which were either suspected or known to contain fluorinated polymers. Product categories included cookware (70-550 000 ppm F), textiles (10-1600 ppm F), electronics (20-2100 ppm F), and personal care products (10-630 000 ppm F). To confirm that the fluorine was organic in nature, and deduce structure, a qualitative pyrolysis-gas chromatography-mass spectrometry (pyr-GC/MS) method was validated using a suite of reference materials. When applied to samples with unknown PFAS content, the method was successful at identifying polytetrafluoroethylene (PTFE) in cookware, dental products, and electronics at concentrations as low as 0.1-0.2 wt%. It was also possible to distinguish between 3 different side-chain fluorinated polymers in textiles. Several products appeared to contain high levels of inorganic fluorine. This is one of the few studies to quantify fluorine in a wide range of consumer plastics and provides important data on the concentration of fluorine in materials which may be intended for recycling, along with insights into the application of pyr-GC/MS for structural elucidation of fluorinated polymers in consumer products.
Collapse
|
3
|
Toward the future of firefighter gear: Assessing fluorinated and non-fluorinated outer shells following simulated on-the-job exposures. JOURNAL OF INDUSTRIAL TEXTILES 2023; 53:10.1177/15280837231217401. [PMID: 38529520 PMCID: PMC10962281 DOI: 10.1177/15280837231217401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
In 2022, the occupation of firefighting was categorized as a "Group 1" carcinogen, meaning it is known to be carcinogenic to humans. The personal protective equipment that structural firefighters wear is designed to safeguard them from thermal, physical, and chemical hazards while maintaining thermo-physiological comfort. Typically, the outer layer of structural turnout gear is finished with a durable water and oil-repellent (DWR) based on per- and polyfluoroalkyl substances (PFAS) that helps limit exposure to water and hazardous liquids. The PFAS-based aqueous emulsion typically used in DWR finishes is highly persistent and can cause various health problems if absorbed into the body through ingestion, inhalation, and/or dermal absorption. In response, the U.S. Fire Service has begun using non-PFAS water repellants in firefighter turnout gear. This study aims to evaluate the performance of both traditional PFAS-based and alternative non-PFAS outer shell materials. The study involved exposing both PFAS-based and non-PFAS DWR outer shell materials in turnout composites to simulated job exposures (i.e., weathering, thermal exposure, and laundering) that artificially aged the materials. After exposures, samples were evaluated for repellency, durability, thermal protection, and surface chemistry analysis to determine any potential performance trade-offs that may exist. Non-PFAS outer shell fabrics were found not to be diesel/oil-repellent, posing a potential flammability hazard if exposed to diesel and subsequent flame on an emergency response. Both PFAS-based and non-PFAS sets of fabrics performed similarly in terms of thermal protective performance, tearing strength, and water repellency. The surface analysis suggests that both PFAS and non-PFAS chemistries can degrade and shed from fabrics during the aging process. The study indicates that firefighters should be educated and trained regarding the potential performance trade-offs, such as oil absorption and flammability concerns when transitioning to non-PFAS outer shell materials.
Collapse
|
4
|
Temporal decline in serum PFAS concentrations among metropolitan firefighters: Longitudinal study on post-exposure changes following PFAS foam cessation. ENVIRONMENT INTERNATIONAL 2023; 179:108167. [PMID: 37651929 DOI: 10.1016/j.envint.2023.108167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2022] [Revised: 08/17/2023] [Accepted: 08/21/2023] [Indexed: 09/02/2023]
Abstract
Firefighters are at a high risk of exposure to per- and polyfluoroalkyl substances (PFAS) due to their frequent use of PFAS-containing foams in training and emergency situations. This longitudinal study aimed to investigate the changes in serum PFAS levels among firefighters following cessation of their exposure to PFAS-containing foams. The study involved 130 firefighters from the South Australian Metropolitan Fire Services (SAMFS), and serum samples were collected at two time points: baseline in 2018-19 and follow-up in 2021-22. Along with the collection of samples, a survey questionnaire was administered to gather information on firefighters' employment and demographic characteristics. Regression models were employed to assess the association between these factors and the outcome variable (annual percentage change in serum PFAS concentration). The results indicated a decline in serum PFAS concentrations over time, with the main contaminants being perfluorooctane sulfonic acid (PFOS), perfluorohexane sulfonate (PFHxS), and perfluorooctanoic acid (PFOA). The median and Interquartile Range (IQR) of total PFAS (∑PFAS) concentration reduced from 21.5 ng/ml (IQR: 11 to 53 ng/ml) at baseline to 15 ng/ml (IQR: 8 to 33 ng/ml) at follow-up. On average, there was an annual reduction of 13%, 7%, and 4.4% in serum concentrations of PFOS, PFHxS, and PFOA, respectively. Firefighters under the age of 55, those who used PFAS in the past ten years, or those who had little to no frequency of PFAS exposure in their previous employment, encountered a significantly higher annual percentage reduction (P < 0.05) in both ∑PFAS and PFOS concentrations. None of the independent variables analysed could significantly predict the annual percentage change in PFOA and PFHxS. This study provides evidence for a declining temporal trend in serum PFAS concentrations among metropolitan firefighters following workplace interventions that involved the removal of PFAS-containing foams.
Collapse
|
5
|
Non-extractable PFAS in functional textiles - characterization by complementary methods: oxidation, hydrolysis, and fluorine sum parameters. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2023; 25:1298-1310. [PMID: 37503704 DOI: 10.1039/d3em00131h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/29/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are widely used for durable water-repellent finishing of different fabrics and textiles such as outdoor clothing, carpets, medical textiles and more. Existing PFAS extraction techniques followed by target analysis are often insufficient for detecting widely used side-chain fluorinated polymers (SFPs) that are barely or non-extractable. SFPs are typically copolymers consisting of a non-fluorinated backbone with perfluoroalkyl side-chains to obtain desired properties. We compared the accessible analytical information and performance of complementary techniques based on oxidation (dTOP and PhotoTOP assays), hydrolysis (THP assay), standard extraction, extractable organic fluorine (EOF), and total fluorine (TF) with five functional textiles and characterized 7 further textiles only by PhotoTOP oxidation. The results show that when applied directly to textile samples, dTOP and PhotoTOP oxidation and also hydrolysis (THP) are able to capture large fractions of TF in the form of perfluoroalkyl side-chains present in the textiles while methods relying on extracts (EOF, target and non-target analysis) yield much lower fractions of TF (e.g., factor ∼25-50 lower). The conversion of large fractions of the measured TF into PFCAs or FTOHs from fluorinated side chains is in contrast to previous studies. Concentrations ranged from
Collapse
|
6
|
Taking a look at the surface: μ-XRF mapping and fluorine K-edge μ-XANES spectroscopy of organofluorinated compounds in environmental samples and consumer products. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2023. [PMID: 37335293 DOI: 10.1039/d3em00107e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/21/2023]
Abstract
For the first time, μ-X-ray fluorescence (μ-XRF) mapping combined with fluorine K-edge μ-X-ray absorption near-edge structure (μ-XANES) spectroscopy was applied to depict per- and polyfluoroalkyl substance (PFAS) contamination and inorganic fluoride in sample concentrations down to 100 μg kg-1 fluoride. To demonstrate the matrix tolerance of the method, several PFAS contaminated soil and sludge samples as well as selected consumer product samples (textiles, food contact paper and permanent baking sheets) were investigated. μ-XRF mapping allows for a unique element-specific visualization at the sample surface and enables localization of fluorine containing compounds to a depth of 1 μm. Manually selected fluorine rich spots were subsequently analyzed via fluorine K-edge μ-XANES spectroscopy. To support spectral interpretation with respect to inorganic and organic chemical distribution and compound class determination, linear combination (LC) fitting was applied to all recorded μ-XANES spectra. Complementarily, solvent extracts of all samples were target-analyzed via LC-MS/MS spectrometry. The detected PFAS sum values range from 20 to 1136 μg kg-1 dry weight (dw). All environmentally exposed samples revealed a higher concentration of PFAS with a chain length > C8 (e.g. 580 μg kg-1 dw PFOS for Soil1), whereas the consumer product samples showed a more uniform distribution with regard to chain lengths from C4 to C8. Independent of quantified PFAS amounts via target analysis, μ-XRF mapping combined with μ-XANES spectroscopy was successfully applied to detect both point-specific concentration maxima and evenly distributed surface coatings of fluorinated organic contaminants in the corresponding samples.
Collapse
|
7
|
Evaluating Neutral PFAS for Potential Dermal Absorption from the Gas Phase. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:4951-4958. [PMID: 36917694 DOI: 10.1021/acs.est.2c08835] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Exposures to per- and polyfluoroalkyl substances (PFAS) are of increasing concern. Assessments typically focus only on ingestion and inhalation exposure due to a lack of generally accepted approaches for estimating dermal absorption. Prior work indicates limited dermal absorption of ionic PFAS, but absorption of neutral PFAS has not been examined from the liquid vehicle or from vapor. Partitioning of semivolatile organic compounds from the gas phase to the skin surface (i.e., stratum corneum) is well known, but the potential for partitioning of neutral PFAS from the gas phase to the stratum corneum has yet to be estimated. The SPARC-estimated physicochemical properties were used to calculate transdermal permeability coefficients (kp_g) and dermal-to-inhalation (D/I) exposure ratios for two groups of neutral PFAS, including those on a U.S. Environmental Protection Agency PFAS list. 11 neutral PFAS gave calculated D/I ratios >5, indicating that direct transdermal absorption may be an important exposure pathway compared to inhalation. Data on consumer products or indoor air is needed for the 11 neutral PFAS, followed by possible biomonitoring to experimentally verify dermal absorption from air. Additional PFAS should be estimated by the protocol used here as they are identified in commercial products.
Collapse
|
8
|
Silicone passive sampling used to identify novel dermal chemical exposures of firefighters and assess PPE innovations. Int J Hyg Environ Health 2023; 248:114095. [PMID: 36508961 PMCID: PMC9930175 DOI: 10.1016/j.ijheh.2022.114095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 11/13/2022] [Accepted: 12/01/2022] [Indexed: 12/14/2022]
Abstract
A plethora of chemicals are released into the air during combustion events, including a class of compounds called polycyclic aromatic hydrocarbons (PAHs). PAHs have been implicated in increased risk of cancer and cardiovascular disease, both of which are disease endpoints of concern in structural firefighters. Current commercially available personal protective equipment (PPE) typically worn by structural firefighters during fire responses have gaps in interfaces between the ensemble elements (e.g., hood and jacket) that allow for ingress of contaminants and dermal exposure. This pilot study aims to use silicone passive sampling to assess improvements in dermal protection afforded by a novel configuration of PPE, which incorporates a one-piece liner to eliminate gaps in two critical interfaces between pieces of gear. The study compared protection against parent and alkylated PAHs between the one-piece liner PPE and the standard configuration of PPE with traditional firefighting jacket and pants. Mannequins (n = 16) dressed in the PPE ensembles were placed in a Fireground Exposure Simulator for 10 min, and exposed to smoke from a combusting couch. Silicone passive samplers were placed underneath PPE at vulnerable locations near interfaces in standard PPE, and in the chamber air, to measure PAHs and calculate the dermal protection provided by both types of PPE. Silicone passive sampling methodology and analyses using gas chromatography with mass-spectrometry proved to be well-suited for this intervention study, allowing for the calculation and comparison of worker protection factors for 51 detected PAHs. Paired comparisons of the two PPE configurations found greater sum 2-3 ring PAH exposure underneath the standard PPE than the intervention PPE at the neck and chest, and at the chest for 4-7 ring PAHs (respective p-values: 0.00113, 0.0145, and 0.0196). Mean worker protection factors of the intervention PPE were also greater than the standard PPE for 98% of PAHs at the neck and chest. Notably, the intervention PPE showed more than 30 times the protection compared to the standard PPE against two highly carcinogenic PAHs, dibenzo[a,l]pyrene and benzo[c]fluorene. Nine of the detected PAHs in this study have not been previously reported in fireground exposure studies, and 26 other chemicals (not PAHs) were detected using a large chemical screening method on a subset of the silicone samplers. Silicone passive sampling appears to be an effective means for measuring dermal exposure reduction to fireground smoke, providing evidence in this study that reducing gaps in PPE interfaces could be further pursued as an intervention to reduce dermal exposure to PAHs, among other chemicals.
Collapse
|
9
|
Food grown on fire stations as a potential pathway for firefighters' exposure to per- and poly-fluoroalkyl substances (PFAS). ENVIRONMENT INTERNATIONAL 2022; 168:107455. [PMID: 35964536 DOI: 10.1016/j.envint.2022.107455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 07/11/2022] [Accepted: 08/02/2022] [Indexed: 06/15/2023]
Abstract
Human exposure to per- and polyfluoroalkyl substances also known as PFAS is an ongoing occupational and environmental health problem. This study seeks to characterise multiple pathways for firefighters' exposure to PFAS. PFAS were analysed in 688 environmental samples such as eggs, fruits, vegetables, dust, soil, surface swabs, appliance washes and water obtained from fire stations. Relevant exposure pathways were identified and daily intake levels were estimated using PFAS concentrations and exposure factors relevant to firefighters. Five PFAS including perfluorooctane sulfonic acid (PFOS), perfluorooctanoic acid (PFOA), perfluorohexane sulfonic acid (PFHxS), 6:2 fluorotelomer sulfonate (6:2 FTS), and 8:2 fluorotelomer sulfonic acid (8:2 FTS) were frequently detected in the samples. Based on the median concentrations in each sample type, PFOS was the most abundant contaminant in eggs (80%), fruits (52%), dust (81%), surface swab (66%), soil (83%) and appliance wash (31%) samples. On the other hand, PFHxS was most abundant in vegetables (77%) and 8:2 FTS in water (58%). The intake estimation results show that dietary exposure from ingestion of foods produced on fire stations was the predominant exposure pathway, representing 82% and 62% of firefighters' total PFAS intake under typical and worst-case exposure scenarios, respectively. Incidental ingestion and dermal absorption of PFAS in dust contributed 15% for typical and 34% for worst-case exposure scenarios. The relative contributions from incidental ingestion and dermal absorption of PFAS in soil and appliance washes were insignificant. Overall, the study identifies multiple exposure pathways relevant to career firefighters including consumption of food grown on fire stations, which has not previously been recognised within the occupational exposure context. The results suggest exposure control strategies that target foods produced on fire stations could substantially reduce firefighters' exposure to PFAS.
Collapse
|
10
|
Hierarchy of contamination control in the fire service: Review of exposure control options to reduce cancer risk. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE 2022; 19:538-557. [PMID: 35853136 PMCID: PMC9928012 DOI: 10.1080/15459624.2022.2100406] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The international fire service community is actively engaged in a wide range of activities focused on development, testing, and implementation of effective approaches to reduce exposure to contaminants and the related cancer risk. However, these activities are often viewed independent of each other and in the absence of the larger overall effort of occupational health risk mitigation. This narrative review synthesizes the current research on fire service contamination control in the context of the National Institute for Occupational Safety and Health (NIOSH) Hierarchy of Controls, a framework that supports decision making around implementing feasible and effective control solutions in occupational settings. Using this approach, we identify evidence-based measures that have been investigated and that can be implemented to protect firefighters during an emergency response, in the fire apparatus and at the fire station, and identify several knowledge gaps that remain. While a great deal of research and development has been focused on improving personal protective equipment for the various risks faced by the fire service, these measures are considered less effective. Administrative and engineering controls that can be used during and after the firefight have also received increased research interest in recent years. However, less research and development have been focused on higher level control measures such as engineering, substitution, and elimination, which may be the most effective, but are challenging to implement. A comprehensive approach that considers each level of control and how it can be implemented, and that is mindful of the need to balance contamination risk reduction against the fire service mission to save lives and protect property, is likely to be the most effective.
Collapse
|
11
|
Widespread Occurrence of Non-Extractable Fluorine in Artificial Turfs from Stockholm, Sweden. ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS 2022; 9:666-672. [PMID: 35966456 PMCID: PMC9367005 DOI: 10.1021/acs.estlett.2c00260] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS) are frequently used in the production of rubber and plastic, but little is known about the identity, concentration, or prevalence of PFAS in these products. In this study, a representative sample of plastic- and rubber-containing artificial turf (AT) fields from Stockholm, Sweden, was subjected to total fluorine (TF), extractable organic fluorine (EOF), and target PFAS analysis. TF was observed in all 51 AT samples (ranges of 16-313, 12-310, and 24-661 μg of F/g in backing, filling, and blades, respectively), while EOF and target PFAS occurred in <42% of all samples (<200 and <1 ng of F/g, respectively). A subset of samples extracted with water confirmed the absence of fluoride. Moreover, application of the total oxidizable precursor assay revealed negligible perfluoroalkyl acid (PFAA) formation across all three sample types, indicating that the fluorinated substances in AT are not low-molecular weight PFAA precursors. Collectively, these results point toward polymeric organofluorine (e.g., fluoroelastomer, polytetrafluoroethylene, and polyvinylidene fluoride), consistent with patent literature. The combination of poor extractability and recalcitrance toward advanced oxidation suggests that the fluorine in AT does not pose an imminent risk to users. However, concerns surrounding the production and end of life of AT, as well as the contribution of filling and blades to environmental microplastic contamination, remain.
Collapse
|
12
|
Neutral Per- and Polyfluoroalkyl Substances, Butyl Carbitol, and Organic Corrosion Inhibitors in Aqueous Film-Forming Foams: Implications for Vapor Intrusion and the Environment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:10785-10797. [PMID: 35852516 DOI: 10.1021/acs.est.2c02349] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Per- and polyfluoroalkyl substances (PFAS), butyl carbitol, and corrosion inhibitors are components of aqueous film-forming foams (AFFFs). Volatile (neutral) fluorotelomerization (FT)- and electrochemical fluorination (ECF)-based PFAS, butyl carbitol, and organic corrosion inhibitors were quantified in 39 military specification (MilSpec), non-MilSpec, and alcohol resistant-AFFF concentrates (undiluted) from 1974 to 2010. Fluorotelomer alcohols were found only in FT-based AFFFs and N-methyl- and N-ethyl-perfluoroalkyl sulfonamides, and sulfonamido ethanols were found only in ECF-based AFFFs. Neutral PFAS and benzotriazole, 4-methylbenzotriazole, and 5-methybenzotriazole occurred at mg/L levels in the AFFFs, while butyl carbitol occurred at g/L levels. Neutral PFAS concentrations in indoor air due to vapor intrusion of a nearby undiluted AFFF release are estimated to be anywhere from 2 to >10 orders of magnitude higher than documented background indoor air concentrations. Estimated butyl carbitol and organic corrosion inhibitor concentrations were lower than and comparable to indoor concentrations recently measured, respectively. The wide range of neutral PFAS concentrations and Henry's law constants indicate that field, soil-gas measurements are needed to validate the estimations. Co-discharged butyl carbitol likely contributes to oxygen depletion in AFFF-impacted aquifers and may hinder the natural PFAS aerobic biotransformation. Organic corrosion inhibitors in AFFFs indicate that these are another source of corrosion inhibitors in the environment.
Collapse
|
13
|
Biomonitoring of per- and polyfluoroalkyl substances (PFAS) exposure in firefighters: Study design and lessons learned from stakeholder and participant engagement. Int J Hyg Environ Health 2022; 242:113966. [DOI: 10.1016/j.ijheh.2022.113966] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2021] [Revised: 03/21/2022] [Accepted: 03/23/2022] [Indexed: 01/09/2023]
|
14
|
Per- and Polyfluoroalkyl Substances (PFAS) in Facemasks: Potential Source of Human Exposure to PFAS with Implications for Disposal to Landfills. ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS 2022; 9:320-326. [PMID: 37599856 PMCID: PMC10438898 DOI: 10.1021/acs.estlett.2c00019] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/22/2023]
Abstract
Facemasks are important tools for fighting against disease spread, including Covid-19 and its variants, and some may be treated with per- and polyfluoroalkyl substances (PFAS). Nine facemasks over a range of prices were analyzed for total fluorine and PFAS. The PFAS compositions of the masks were then used to estimate exposure and the mass of PFAS discharged to landfill leachate. Fluorine from PFAS accounted only for a small fraction of total fluorine. Homologous series of linear perfluoroalkyl carboxylates and the 6:2 fluorotelomer alcohol indicated a fluorotelomer origin. Inhalation was estimated to be the dominant exposure route (40%-50%), followed by incidental ingestion (15%-40%) and dermal (11%-20%). Exposure and risk estimates were higher for children than adults, and high physical activity substantially increased inhalation exposure. These preliminary findings indicate that wearing masks treated with high levels of PFAS for extended periods of time can be a notable source of exposure and have the potential to pose a health risk. Despite modeled annual disposal of ~29-91 billion masks, and an assuming 100% leaching of individual PFAS into landfill leachate, mask disposal would contribute only an additional 6% of annual PFAS mass loads and less than 11 kg of PFAS discharged to U.S. wastewater.
Collapse
|